Cold Cathode Ballast

Transcription

Cold Cathode Ballast
Generated by PDFKit.NET Evaluation
Cold Cathode Ballast
u
u
u
u
u
u
Complies with UL 935 Standard
CAN be used with External Flashers and Dimmers
Maximum 990 Volts to Ground
Class P Thermally Protected
Slotted Mounting Holes for Easy Retrofit
Internal Wiring Compartments on Both Ends Eliminates
External Wiring Boxes
u High Power Factor Models Available
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
Cold Cathode Ballast
Cold Cathode Instant Start Lamp Ballasts
Normal Power Factor
One or Two Lamps
CATALOG LAMP FOOTAGE
PRIMARY
NUMBER
VOLTS HZ V.A. AMPS
MIN
MAX
2815 D
2820 D
2815 K
2820 K
8
8
8
8
16
16
16
16
120
120
277
277
60
60
60
60
3.0
3.7
1.5
1.7
360
450
415
470
SECONDARY
VOLTS mA
990
990
990
990
LEAD LENGTH
INCHES
WEIGHT
LBS.
150
200
150
200
10
10
10
10
20
21
20
21
200
200
10
10
21
21
High Power Factor
Two 8 FT Lamps Only
2820 DH
2820 KH
16
16
16
16
120
277
2.1
1.0
60 240
60 249
990
990
16.724
1.250
TYP
1.753
TYP
17.600
.250 X .500 SLOT
TYP 4 PLCS
.438
TYP
16.724
.688
TYP
3.776
3.476
2.000
TYP
.312
TYP
.750 1.250
TYP TYP
email: [email protected]
xs09029 07/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P 6 K A 2 N G Cold Cathode
Transformer
ndle
a
H
y
Carr
y
s
a
PE
itch
w
S
f
f
POn/O
u UL 2161 Listed and NEC Compliant
u Available in a variety of models
Primary voltages of 120 or 277.Secondaries
from 5000 to 9000 volts -120mA.
u Secondary Circuit Ground Fault Protection
Disables unit upon detection of arcs to
ground and other conditions which may
compromise transformer performance.
Resists nuisance tripping.
u Easy Wiring Methods
Virtual Ground and Series Wiring Methods.
u Self Enclosed
u Auto Reset
Doesn’t require separate enclosure.
After fault, automatically attempts to reset
three (3) times within approximately ten (10) u Multiple Knockouts
seconds reducing nuisance tripping. Manual
Allows for a variety of mounting configurations
reset possible at any time.
u “Easy Off” Cover
u Outdoor Non-weatherproof
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
Cold Cathode
Transformer
P6KA2NG
NORMAL POWER FACTOR
Catalog
Number
90120 P6KA2NG
75120 P6KA2NG
60120 P6KA2NG
50120 P6KA2NG
90120 P6KA2NG
75120 P6KA2NG
60120 P6KA2NG
50120 P6KA2NG
VAC Hz
120
120
120
120
277
277
277
277
Secondary
Volts mA
60 9000 120
60 7500 120
60 6000 120
60 5000 120
60 9000 120
60 7500 120
60 6000 120
60 5000 120
Primary Input Wt.
Amp. Lbs.
VA
9.0
7.5
6.0
5.0
4.0
3.3
2.6
2.3
1080
900
720
600
1080
900
720
600
45
42
30
29
45
42
30
29
Case Dimensions
A
H
B
L
W
17.55
17.55
13.35
13.35
17.55
17.55
13.35
13.35
4.62
4.62
4.62
4.62
4.62
4.62
4.62
4.62
8.00
8.00
8.47
8.47
8.00
8.00
8.47
8.47
15.07
15.07
10.87
10.87
15.07
15.07
10.87
10.87
C
16.41
16.41
12.21
12.21
16.41
16.41
12.21
12.21
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
Contact FRANCE for information on Other Secondary Voltage and mA Requirements.
What may cause the S.C.G.F.P. circuit in the P 6KA2NG to trip:
u Reversing the hot (black) or neutral (white) input power wires.
u Leaving the service ground unconnected.
u Connecting or grounding the midpoint of a sign to Earth ground.
u Excessive leakage currents caused from excessive moisture within or on the sign,
tubing installed too close to metal, corroded insulators or standoffs, or conductive
debris such as insects, dirt, etc. between live high voltage sign components and ground.
u Electrical shorting or arcing from live high voltage sign components to ground.
When will a S.C.G.F.P. circuit in the P 6KA2NG not trip:
u Ground faults on the primary/line side of the transformer.
u Series arcs in the sign system (arcs across sign tubing interconnections).
u Breaks in the sign tubing, degassed tubing, or opens in the high voltage
connections without a corresponding short or arc to ground.
u Shorts to an ungrounded metal part within or near a sign.
A
W
NO PCB
.970
ON
OFF
1.456
H
3.338
L
B
C
.375 X .750
SLOT, 4 PLCS
email: [email protected]
Copyright 2001
xs09014 05/18/2009
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
Ser viceMaster - Open Core & Coil
Universal Replacement Units
3020 SEG-U
6025 SEG-U
u Designed for indoor use in small signs where space is at a
premium
u Utilizes a high quality Polyester impregnation to guard against
moisture absorption
u Primary leads and highly flexible GTO-10 Secondary leads
are 6” long on 3020 and 14” long on 6025.
u 3020 - One End Ground, self-adjusting 2000 to 3000 Volts
u 6025 - Mid-Point Ground, self-adjusting 3500 to 6000 Volts
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
SEG -U - Open Core & Coil
Catalog
Number
VAC
HZ
Secondary Primary
VA
Volts mA
Input Wt.
Amp lbs.
6025 SEG-U
3020 SEG-U
120
120
60
60
6000
3000
1.60
0.70
25
20
190
85
7.7
3.4
Case Dimensions in Inches
A
W
H
B
3.250 3.062 5.688 2.562
6.250
3.687 2.812 3.062 3.125 2.125
L
L
3020 SEG-U
H
A
W
B
H
L
A
W B
6025 SEG-U
email: [email protected]
xs09018 06/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
WINDOW FRAME
6000 FE1G
9000 FE1G
u Self-Adjusting -
12000 FE1G
u 6000V and 9000V available in Non-
6000 FE1G & 6000 FE1G-D
2000 - 6000V
9000 FE1G & 9000 FE1G-D
2000 - 9000V
12000 FE1G-D
2000 - 12000V
u Secondary Circuit Ground Fault
Protection
Detects arcs to ground and disables
unit. Power supply must be
manually reset.
Dimming & Dimming versions.
12000V Model Dimming Only.
u UL 2161 Listed Type 7
u No Jelly-Beaning or Mercury
Migration
u Vacuum Encapsulated High Voltage
Section
Protects High Voltage circuitry and
reduces heat.
u Open Circuit Detection
Detects opens in High Voltage
circuit and disables unit. Power
supply must be manually reset.
u Lightweight
u 10' Line Cord
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753 fax 615-799-3199
Generated by PDFKit.NET Evaluation
Window F rame
Specifications - at 120 VAC, 60 Hz
Secondary
Voltage
mA
6000 Series 2-6 kV*
36**
9000 Series 2-9 kV*
34**
12000 Series 2-12 kV* 40**
Catalog
Number
Primary
VA
Input
Amps
102
180
228
.85
1.3
1.9
Dimensions in Inches
D
E
C
A
B
5.700 1.750 3.125 1.600 5.900
5.750 2.125 4.125 2.875 6.000
5.625 2.100 4.125 2.875 5.900
F
6.500
6.875
6.825
Weight
in lbs.
1.6
2.2
2.9
E
A
C D
B
F
*See notes regarding Dimming Models.
** Short circuit secondary current. All models actually operate tubing at a current that produces the same
tubing brightness (comparable to core/coil transformers).
Each power supply is complete with a 10’ three-conductor line cord with 3-prong plug, a pull-chain On/Off
switch, and 18” long secondary GTO leads.
Frequency: 20 kHz
Dimming Models:
To dim models equipped with the dimming feature (-D models), use the rocker switch located on the end panel (9000
volt & 12000 volt models) or side (6000 volt models) of the power supplies. When dimmed, power supplies will provide
light output comparable to a 20 mA unit. Reductions in tubing load may be required when dimming neon-filled tubing.
email: [email protected]
xs09020 07/07/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P-ESE Ener g y Saver
=
Less Energy = More money
in your pocket!!
Uses 20-25% less energy than
standard neon transformers.
Same watts per foot as most LED
systems on the market.
Diagnostic Circuit - “LED” indicates
the reason for service, allowing for
quick, easy troubleshooting.
Primary Wiring Requirements of a
Non-SCGFP - with the added safety
of Secondary Ground Fault Protection.
Service Button - For easy
troubleshooting of ground faults and
primary wiring problems. Overrides
the SCGFP for up to 30 minutes.
Self-Adjusting - 2 Models 3000 - 15000
Auto Reset - After secondary ground
fault, automatically attempts to reset three
times within ten seconds. Manual reset
possible at any time, by disconnecting
primary power.
Secondary Circuit Ground Fault
Protection - (SCGFP) Disables unit upon
detection of arcs to ground in compliance
with UL2161 and NEC requirements.
Ready to Mount. Step Plate eliminates
double-nutting.
Easy Wiring Methods - Virtual Ground
and Series Wiring Methods
User Friendly - Adapts to most
grounding situations.
*Can be used in flashing applications.
* UL does not have listing requirements for transformers that are remotely
dimmed or flashed.
www.franceformer.com
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P-ESE Ener g y Saver
ENERGY SAVER
ServiceMaster
REPLACES
Service
Button
“LED”
Indicator
Catalog
Number
VAC
Hz
15000 P-ESE
9000 P-ESE
120
120
60
60
NORMAL POWER FACTOR
Secondary Primary Input
Wt.
Amps Lbs.
V.A.
Volts mA
L
15000
9000
20
20
170
190
1.40
1.60
27
13
9.20
8.37
W
Case Dimensions
A
H
4.65
3.70
6.045
4.890
B
C
10.13 11.25 3.00
9.00 10.00 2.00
Note:
Only use with P-ESE Models. Do Not mix P5G-2E Models.
2268 Fairview Blvd
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
xs09007 07/07/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5K A2NG -2E Series
NO Transformer Box
Required for
Interior Installations!
“LED”
Indicator
“ENFORMER”
Service
Button
ON/OFF
Toggle Switch
Diagnostic Circuit- “LED” indicates
the reason for service, allowing for
quick, easy troubleshooting.
Primary Wiring Requirements of a
Non-SCGFP - with the added safety
of Secondary Ground Fault Protection.
Service Switch - For easy
troubleshooting of ground faults and
primary wiring problems. Overrides
the SCGFP for up to 30 minutes.
Auto Reset - After secondary ground
fault, automatically attempts to reset
three times within ten seconds. Manual
reset possible at any time by
disconnecting primary power.
*Can be used in flashing/dimming
applications.
Secondary Circuit Ground Fault
Protection - (SCGFP) Disables unit
upon detection of arcs to ground in
compliance with UL2161 and NEC
requirements.
Easy Wiring Methods - Virtual
Ground and Series Wiring Methods
User Friendly - Adapts to most
grounding situations.
Easy to carry handle.
On/Off Toggle Switch.
*UL does not have listing requirements for transformers that are
remotely dimmed or flashed.
www.franceformer.com
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5K A2NG -2E Series
NORMAL POWER FACTOR
Catalog
Number
VAC Hz
15030 P5KA2NG-2E
12030 P5KA2NG-2E
10530 P5KA2NG-2E
9030 P5KA2NG-2E
7530 P5KA2NG-2E
6030 P5KA2NG-2E
5030 P5KA2NG-2E
4030 P5KA2NG-2E
15060 P5KA2NG-2E
12060 P5KA2NG-2E
9060 P5KA2NG-2E
7560 P5KA2NG-2E
15030 P5KA2NG-2E
12030 P5KA2NG-2E
10530 P5KA2NG-2E
9030 P5KA2NG-2E
7530 P5KA2NG-2E
6030 P5KA2NG-2E
5030 P5KA2NG-2E
4030 P5KA2NG-2E
120
120
120
120
120
120
120
120
120
120
120
120
277
277
277
277
277
277
277
277
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Secondary
Volts mA
15000
12000
10530
9000
7500
6000
5000
4000
15000
12000
9000
7500
15000
12000
10530
9000
7500
6000
5000
4000
30
30
30
30
30
30
30
30
60
60
60
60
30
30
30
30
30
30
30
30
Primary
V.A.
435
380
310
285
250
200
170
140
900
720
565
460
425
385
310
275
235
190
160
130
Input Wt.
Amp. Lbs.
3.60
3.15
2.55
2.35
2.10
1.65
1.40
1.15
7.50
6.00
4.70
3.85
1.55
1.40
1.15
1.00
.85
.70
.60
.50
25
23
23
19
17
16
16
15
30
29
27
25
25
23
23
19
17
16
16
15
Case Dimensions
A
H
B
L
W
13.35
13.35
13.35
13.35
13.35
13.35
13.35
13.35
14.85
14.85
13.35
13.35
13.35
13.35
13.35
13.35
13.35
13.35
13.35
13.35
4.50
4.50
4.50
4.50
4.00
4.00
4.00
4.00
5.50
5.50
4.50
4.50
4.50
4.50
4.50
4.50
4.00
4.00
4.00
4.00
7.42
7.42
7.42
7.42
6.13
6.13
6.13
6.13
8.47
8.47
7.42
7.42
7.42
7.42
7.42
7.42
6.13
6.13
6.13
6.13
C
12.21
12.21
12.21
12.21
12.21
12.21
12.21
12.21
13.71
13.71
12.21
12.21
12.21
12.21
12.21
12.21
12.21
12.21
12.21
12.21
10.87
10.87
10.87
10.87
10.87
10.87
10.87
10.87
12.37
12.37
10.87
10.87
10.87
10.87
10.87
10.87
10.87
10.87
10.87
10.87
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
A
W
NO PCB
“LED"
INDICATOR
.940
ON
OFF
Toggle
Switch
20 amp 120V
Service
Switch
1.49
H
3.35
Service Switch does not
operate without proper grounding.
L
B
(MTG)
DIAGNOSTIC LED OPERATION
Indicates
LED Fault Code
Steady ON
Continuous Flashing
1 - Flash
2 - Flash
3 - Flash
4 - Flash
5 - Flash
Operating normally
In Service Mode
15 second Diagnostic & Auto Reset Mode
Secondary Ground Fault with service ground connected
Secondary Ground Fault when service ground not connected
Input Voltage exceeds 120% of rated
Line & Neutral reversed on input connections
C
.375 X .750
SLOT, 4 PLCS
2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-753-2753 w fax 615-799-3199
xs09005 04/29/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
High Output 800mA
Rapid S t art Lamp Ballast s
Available in
120V DR & 277V KR
u Thermally Protected
u Extra Long Lead Wires
u Slotted Mounting Holes Allow for Easy Retro-Fit
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
High Output 800mA
Rapid S t art Lamp Ballast s
DR Models 120 VAC / 60 Hz
Catalog
Model
No.
(1)
Min. Starting temperature - 20° F
High Power Factor
KR Models 277 VAC / 60 Hz
Lamp
Max. Open
Footage Line Circuit
Min. Max. Amp. Voltage**
Length2
Net.
In Inches
Wt.
Case Mount Lbs.
Catalog
Model
No.
Lamp
Max. Open
Net.
Length2
In Inches
Footage Line Circuit
Wt.
Min. Max. Amp. Voltage** Case Mount Lbs.
ONE Lamp
168 DR
268 DR
2
4
6
8
0.66
1.20
390
500
10.50
10.50
11.3
11.3
10
11
ONE Lamp
268 KR
288 KR
4
4
8
8
0.55
0.77
500
550
10.50
10.50
11.3
11.3
11
11
TWO Lamps
268 DR
288 DR
2128 DR
388 DR
448DR
458DR
468DR
4
8
16
16
6
8
16
12
16
24
24
16
20
24
1.20
1.80
2.20
2.70
2.00
2.30
2.80
500
530
720
720
550
590
720
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11
11
12
12
11
12
12
TWO Lamps
268 KR
288 KR
2128 KR
388 KR
448 KR
458 KR
468 KR
4
8
16
16
6
8
16
12
16
24
24
16
18
24
0.55
0.77
0.9
1.1
0.8
0.95
1.1
500
550
720
720
550
590
720
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11
11
12
12
11
12
12
12
18
24
36
16
20
24
32
40*
1.40
2.00
2.70
3.60
2.00
2.30
2.80
3.20
4.00
500
590
720
1000
550
590
720
940
720
10.50
10.50
10.50
15.25
10.50
10.50
10.50
15.25
15.25
11.3
11.3
11.3
16.05
11.3
11.3
11.3
16.05
16.05
11
10
12
23
11
12
12
18
19
THREE Lamps
368 KR
8 18
388 KR
16 24
448 KR
6 16
458 KR
8 18
468 KR
16 24
488 KR
20 32
588 KR
16 40
0.86
1.1
0.8
0.95
1.1
1.4
1.7
590
720
550
590
720
940
720
10.50
10.50
10.50
10.50
10.50
15.25
15.25
11.3
11.3
11.3
11.3
11.3
16.05
16.05
10
12
11
12
12
18
19
FOUR Lamps
448 KR
6
458 KR
8
468 KR
16
488 KR
20
4128 KR 36*
568 KR
20
588 KR
16*
668 KR
24
688 KR
36*
16
18
24
32
48*
30
40*
36
48*
0.8
0.95
1.1
1.4
1.7
1.5
1.7
1.7
1.75
550
590
720
940
720
900
720
1000
720
10.50
10.50
10.50
15.25
15.25
15.25
15.25
15.25
15.25
11.3
11.3
11.3
16.05
16.05
16.05
16.05
16.05
16.05
11
12
12
18
25
17
19
18
20
FIVE Lamps
568 KR
588 KR
668 KR
688 KR
20 30
16* 40*
24 36
36* 48*
1.5
1.7
1.7
1.75
900
720
1000
720
15.25
15.25
15.25
15.25
16.05
16.05
16.05
16.05
17
19
18
20
SIX Lamps
668 KR
688 KR
24 36
36* 48*
1.7
1.75
1000
720
15.25
15.25
16.05
16.05
18
20
THREE Lamps
348 DR
6
368 DR
12
388 DR
16
3128 DR
26
448 DR
6
458 DR
8
468 DR
16
488 DR
20
588 DR
16*
FOUR Lamps
448 DR
6
458 DR
8
468 DR
16
488 DR
20
4128 DR 36*
568 DR
20
588 DR
16*
668 DR
24
688 DR
36*
FIVE Lamps
568 DR
588 DR
668 DR
688 DR
16
20
24
32
48*
30
40*
36
48*
20 30
16* 40*
24 36
36* 48*
2.00
2.30
2.80
3.20
3.90
3.20
4.00
4.05
5.00
3.20
4.00
4.05
5.00
550
590
720
940
720
900
720
1000
720
900
720
1000
720
10.50
10.50
10.50
15.25
15.25
15.25
15.25
15.25
15.25
15.25
15.25
15.25
15.25
11.3
11.3
11.3
16.05
16.05
16.05
16.05
16.05
16.05
16.05
16.05
16.05
16.05
11
12
12
18
25
17
19
18
20
17
19
18
20
SIX Lamps
668 DR
24 36
4.05
1000
15.25 16.05 18
688 DR
36* 48* 5.00
720
15.25 16.05 20
* For ballasts having multi-lamp capacity, consult wiring diagram for
proper installation.
** All ballasts have a maximum 600 V to ground.
NOTES:
(1) Ballasts are not recommeded for use with external flashers or
dimmers.
(2) Cross-sectional dimensions are 3.174” wide and 2.79” high.
Mouting holes are 2” apart.
The SIGN MAN’S SIX are printed in RED.
email: [email protected]
xs09026 06/25/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
Space Savings
Reliable Performance
The P5G-2ELP Low Profile
Neon Power Supply saves
space and improves installation
flexibility.
Space Saving
Shallow raceways are no longer a
challenge with this innovative design.
At only 3.4 inches in height, this new
power supply will fit easily into tight
spaces.
Flexible Configuration
Available in a 120v and a 277v primary
version, and in a 9030 and 7530
configuration, the P5G-2ELP will meet
many different sign configurations.
Reliable Design
UL2161 secondary ground fault
protection, pre-wired primary leads, and
last-fault diagnostics are standard in
this power supply backed by France
reliability.
Click here to unlock PDFKit.NET
Made in the USA
Generated by PDFKit.NET Evaluation
P5G-2ELP
Electrical and Mechanical Data
Catalog
Number
9030
7530
9030
7530
P5G-2ELP
P5G-2ELP
P5G-2ELP
P5G-2ELP
277
277
VAC
Hz
Secondary Primary Input Wt.
VA
Amps Lbs.
Volts mA
120
120
277
277
60
60
60
60
9000
7500
9000
7500
30
30
30
30
285
250
280
235
2.35
2.10
1.00
0.85
15.5
15.5
15.5
15.5
Case Dimensions
L
W
H
A
B
C
D
E
F
10.00
10.00
10.00
10.00
3.69
3.69
3.69
3.69
3.40
3.40
3.40
3.40
8.37
8.37
8.37
8.37
2.05
2.05
2.05
2.05
9.00
9.00
9.00
9.00
1.31
1.31
1.31
1.31
2.18
2.18
2.18
2.18
1.88
1.88
1.88
1.88
DIAGNOSTIC LED FAULT CODES
LED Fault Code
Indicates
Steady ON
Continuous Flashing
1 - Flash
2 - Flash
3 - Flash
4 - Flash
5 - Flash
Operating normally
In Service Mode
15 second Diagnostic &
Auto Reset Mode
Secondary Ground Fault with service ground connected
Secondary Ground Fault when service ground not connected
Input V olt age exceeds 120% of rated
Line & Neutral reversed on input connections
Click here to unlock PDFKit.NET
xs09004 02/18/09
Generated by PDFKit.NET Evaluation
Channel Letter
7500 OE1G
5000 OE1G
10000 OE1G
Fits Inside Channel Letters Under
1 3/4” High Tubing.
w UL2161 Listed Type 3
Neon Power Supply
(Outdoor Non-Weatherproof)
2005 NEC Compliant
Circuit Ground Fault
w Secondary
Protection with Auto-Restart
=
=
=
w
Open Circuit Protection
=
=
w
Detects arcs to ground and disables
unit.
Unit will attempt 2 restarts before
tripping off.
Power Supply can be manually reset
if unit trips off.
Detects open circuits in high
voltage circuit and disables unit.
Power Supply can be manually reset
if unit trips off.
Operating Range
-30 degrees F to 122 degrees F
w
Self Adjusting for Line & Load from
1 to 5, 7.5 & 10 kV.
w
w
w
30mA Self Adjusting Output
w
No Jelly-Beaning
w
Grounded Mounting Foot
w
Built-in GTO Fittings for Sleeving
w
1/2” Conduit Fitting for Primary
Wiring
High Power Factor
No Mercury Migration
www.franceformer.com
2268 Fairview Blvd.
Click here to unlock PDFKit.NET
P.O. Box 300
Fairview, TN 37062
voice 1- 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
Channel Letter
CATALOG
NUMBER
EQUIVALENT
SECONDARY
PRIMARY
VOLTAGE FREQUENCY CURRENT VOLTAGE CURRENT
5000 OE1G
7500 OE1G
120 V
10000 OE1G
120
120 VV
50/60
HZ
50/60
HZ
50/60
HZ
(+-10%)
120 V
(+-10%)
(+(-+-10%)
10%)
B
NEON
MERCURY
0.5 A
5000V
30mA
14 FT
16 FT
0.75 A
7500V
30mA
21 FT
25 FT
1.0 A
10,000V
30mA
29 FT
34 FT
A
E
32” OUTPUT
LEADS
1WF8
12mm TUBE LOADING
D
42” INPUT
LEADS
NEON TUBING
F
1 3/4”
C
TUBE SUPPORT
CATALOG
NUMBER
5000 OE1G
7500 OE1G
10000 OE1G
DIMENSIONS IN INCHES
A
B
C
D
E
F
6.88
1.95
1.45
1.38
6.65
6.65
3.13
3.54
1.55
1.55
2.25
2.25
6.50
6.13
6.13
6.00
5.65
5.65
WEIGHT
LBS
1.4
2.1
2.5
email: [email protected]
xs09015 6/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5G -2E
P5CG -2E
Series
P5CG-2E
High Power
Factor
P5G-2E
Normal Power
Factor
“LED”
Indicator
u Primary Wiring Requirements of a u User Friendly - Adapts to any grounding
situation.
Standard Transformer - with the
added safety of Secondary Ground
Fault Protection.
u Bypass Feature - For easy
troubleshooting of ground faults and
primary wiring problems. Overrides
the SCGFP for up to 30 minutes.
u Diagnostic Circuits - “LED” indicates
u Secondary Circuit Ground Fault
Protection - (SCGFP) Disables unit upon
detection of arcs to ground in compliance
with UL2161 and NEC requirements.
u *Can be used in flashing/dimming
applications.
the reason for service, allowing for
quick, easy troubleshooting.
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
NORMAL POWER FACTOR
Catalog
Number
VAC
Hz
15030 P5G-2E
12030 P5G-2E
10530 P5G-2E
9030 P5G-2E
7530 P5G-2E
6030 P5G-2E
5030 P5G-2E
4030 P5G-2E
15060 P5G-2E
12060 P5G-2E
9060 P5G-2E
7560 P5G-2E
6060 P5G-2E
5060 P5G-2E
4060 P5G-2E
15030 P5G-2E
12030 P5G-2E
10530 P5G-2E
9030 P5G-2E
7530 P5G-2E
6030 P5G-2E
5030 P5G-2E
4030 P5G-2E
15060 P5G-2E
12060 P5G-2E
9060 P5G-2E
7560 P5G-2E
6060 P5G-2E
5060 P5G-2E
4060 P5G-2E
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Catalog
Number
VAC
Hz
120
120
120
120
120
60
60
60
60
60
Secondary Primary Input
Wt.
Amps Lbs.
VA
Volts mA
3.60
21
435
15000 30
3.15
18
12000 30
380
18
310
10500 30
2.55
13
2.35
9000 30
285
2.10
7500 30
250
12
200
1.65
6000 30
12
5000 30
1.40
170
12
4000 30
140
11
1.15
7.50
39
900
15000 60
6.00
37
720
12000 60
9000 60
24
565
4.70
3.85
7500 60
21
460
19
6000 60
3.10
370
5000 60
18
2.60
310
2.20
13
4000 60
265
15000 30
21
425
1.55
19
1.40
385
12000 30
310
19
10500 30
1.15
13
275
9000 30
1.00
12
7500 30
235
.85
190
12
6000 30
.70
.60
12
5000 30
160
11
130
.50
4000 30
940
3.40
15000 60
39
750
2.70
12000 60
37
9000 60
560
2.05
24
21
1.65
7500 60
460
1.41
6000 60
385
20
5000 60
330
1.20
19
4000 60
0.87
13
240
HIGH POWER FACTOR
Secondary Primary
Input
Wt.
Amps
Lbs.
VA
Volts mA
26
240
2.00
15000 30
1.60
25
12000 30
190
21
1.40
10500 30
170
19
145
9000 30
1.20
1.00
19
7500 30
120
120
120
120
120
120
120
120
60
60
60
60
60
60
60
15000
12000
9000
7500
6000
5000
4000
15030 P5CG-2E
12030 P5CG-2E
10530 P5CG-2E
9030 P5CG-2E
7530 P5CG-2E
15060 P5CG-2E
12060 P5CG-2E
9060 P5CG-2E
7560 P5CG-2E
6060 P5CG-2E
5060 P5CG-2E
4060 P5CG-2E
60
60
60
60
60
60
60
495
400
300
240
190
170
145
4.15
3.35
2.50
2.00
1.60
1.40
1.20
39
37
26
26
26
21
21
Case Dimensions
L
W
H
11.25
11.25
11.25
10.00
10.00
10.00
10.00
10.00
13.00
13.00
11.25
11.25
11.25
11.25
10.00
11.25
11.25
11.25
10.00
10.00
10.00
10.00
10.00
13.00
13.00
11.25
11.25
11.25
11.25
10.00
4.656
4.656
4.656
3.700
3.700
3.700
3.700
3.700
5.375
5.375
4.656
4.656
4.656
4.656
3.700
4.656
4.656
4.656
3.700
3.700
3.700
3.700
3.700
5.375
5.375
4.656
4.656
4.656
4.656
3.700
5.205
5.205
5.205
4.890
4.890
4.890
4.890
4.890
6.200
6.200
5.205
5.205
5.205
5.205
4.890
5.205
5.205
5.205
4.890
4.890
4.890
4.890
4.890
6.200
6.200
5.205
5.205
5.205
5.205
4.890
A
9.203
9.203
9.203
8.375
8.375
8.375
8.375
8.375
10.875
10.875
9.203
9.203
9.203
9.203
8.375
9.203
9.203
9.203
8.375
8.375
8.375
8.375
8.375
10.875
10.875
9.203
9.203
9.203
9.203
8.375
B
10.125
10.125
10.125
9.000
9.000
9.000
9.000
9.000
11.875
11.875
10.125
10.125
10.125
10.125
9.000
10.125
10.125
10.125
9.000
9.000
9.000
9.000
9.000
11.875
11.875
10.125
10.125
10.125
10.125
9.000
C
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
2.0
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
2.0
Case Dimensions
L
W
H
A
B
C
11.25
11.25
11.25
11.25
11.25
4.656
4.656
4.150
4.150
4.150
6.062
6.062
5.580
5.580
5.580
9.203
9.203
9.203
9.203
9.203
10.125
10.125
10.125
10.125
10.125
3.0
3.0
3.0
3.0
3.0
13.00
13.00
11.25
11.25
11.25
11.25
11.25
5.375
5.375
4.656
4.656
4.656
4.150
4.150
6.200 10.875
6.200 10.875
6.062 9.203
6.062 9.203
6.062 9.203
5.580 9.203
5.580 9.203
11.875
11.875
10.125
10.125
10.125
10.125
10.125
3.0
3.0
3.0
3.0
3.0
3.0
3.0
A
H
“LED”
Indicator
L
B
W
C
The 9030 P5G-2E & 7530 P5G-2E has
horizontal mounting of primary bushing as
shown in diagram above.
.375” X .750”
SLOTS, 4 PLCS
This end view of primary bushing is
applicable to all units except
the 9030 P5G-2E & 7530 P5G-2E.
* UL does not have listing requirements
for transformers that are remotely dimmed or flashed.
* High Power Factor Models may not be dimmed.
xs09006 04/29/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5G-2UE ServiceMaster
Universal Replacement
Service Units
Ever wish you
had 8 arms?
With the “ServiceMaster”
you only need 2!
True 30mA & 60mA Output - The
“ServiceMaster” can replace 8 ratings.
Ready to Mount. Step Plate
eliminates double-nutting.
Auto Reset - After secondary ground
fault, automatically attempts to reset three
times within ten seconds. Manual reset
possible at any time, by disconnecting
primary power.
Diagnostic Circuit - “LED” indicates
the reason for service, allowing for
quick, easy troubleshooting.
Secondary Circuit Ground Fault
Protection - (SCGFP) Disables unit upon
detection of arcs to ground in compliance
with UL2161 and NEC requirements.
Primary Wiring Requirements of a
Non-SCGFP - with the added safety
of Secondary Ground Fault Protection.
Easy Wiring Methods - Virtual Ground
and Series Wiring Methods
Service Button - For easy
troubleshooting of ground faults and
primary wiring problems. Overrides
the SCGFP for up to 30 minutes.
User Friendly - Adapts to most
grounding situations.
*Can be used in flashing/dimming
applications.
* UL does not have listing requirements for transformers that are remotely
dimmed or flashed.
www.franceformer.com
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
SERVICE
MASTER
REPLACES
15030 & 15060 P5G-2UE
9030 & 9060 P5G-2UE
15000, 12000 & 10500 Volt
9000, 7500, 6000, 5000, 4000, 3000 & 2000 Volt
Service
Button
“LED”
Indicator
L
H
.500”
B
The 9030 P5G-2U has horizontal
mounting of primary bushing as
shown in diagram above.
A
This end view of primary bushing is
applicable to the 9060,15030 & 15060 P5G-2U only.
.375” X .750”
SLOTS, 4 PLCS
W C
Catalog
Number
VAC
Hz
15030 P5G-2UE
9030 P5G-2UE
15030 P5G-2UE
9030 P5G-2UE
15060 P5G-2UE
9060 P5G-2UE
15060 P5G-2UE
9060 P5G-2UE
120
120
277
277
120
120
277
277
60
60
60
60
60
60
60
60
2268 Fairview Blvd
NORMAL POWER FACTOR
Secondary Primary Input
Wt.
Amps Lbs.
V.A.
Volts mA
L
15000
9000
15000
9000
15000
9000
15000
9000
PO Box 300
30
30
30
30
60
60
60
60
510
330
530
320
940
600
980
610
4.25
2.75
1.90
1.15
7.80
5.00
3.60
2.20
21
13
21
13
39
23
39
23
Fairview, TN 37062
9.20
8.37
9.20
8.37
10.87
9.20
10.87
9.20
W
Case Dimensions
A
H
4.65
3.70
4.65
3.70
5.37
4.65
5.37
4.65
5.71
5.39
5.71
5.39
6.20
5.71
6.20
5.71
voice 800-753-2753
10.13
9.00
10.13
9.00
11.88
10.13
11.88
10.13
B
C
11.25
10.00
11.25
10.00
13.00
11.25
13.00
11.25
3.00
2.00
3.00
2.00
3.00
3.00
3.00
3.00
fax 615-799-3199
xs09003 04/29/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P8G-2B Series
Neon Transformers
P8G-2B Features
>Easy access terminals
>Service switch
>Top visible diagnostic LED
>Pre-wired primary leads
>Carry handle
>UL compliant stepped
base plate
Ease of Installation - Patented angled bushings for
greater visibility and ease of access to electrical
connections, LED, and service button. Does not
block mounting screws and the step plate
eliminates double-nutting.
Visible advanced diagnostic LED - Faster, easier
troubleshooting is provided by an intelligent circuit
that detects both primary and secondary faults and
communicates the cause of the fault using the on
-board LED.
Built-in carrying handle
Primary wiring requirements of a non-SGFI
transformer - With the added safety of a Secondary
Ground Fault Protection with simple wire nut
connections.
User friendly - Adapts to most grounding situations.
Easy wiring methods - Virtual midpoint and series
wiring methods.
Secondary Circuit Ground Fault Protection (SGFP) Disables unit upon detection of arcs to
ground in compliance with UL2161, C22.2 No. 255,
and NEC requirements.
Auto reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible any any time by disconnecting and reconnecting primary power.
Last Fault Recall - Allows service technician to
retrieve the last fault experienced, even after the fault
condition has been cleard.
Bypass feature - For easy troubleshooting of ground
faults, overrides the SGFP feature for up to 30
minutes.
Can be used in flashing/dimming applications*
*UL does not have listing requirements for
transformers remotely dimmed or flashed
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
Electrical and Mechanical Data
Cat alog
Number
15030 P8G-2E
12030 P8G-2E
10530 P8G-2E
9030 P8G-2E
7530 P8G-2E
6030 P8G-2E
5030 P8G-2E
4030 P8G-2E
9060 P8G-2E
7560 P8G-2E
6060 P8G-2E
5060 P8G-2E
4060 P8G-2E
15030 P8G-2E
12030 P8G-2E
10530 P8G-2E
9030 P8G-2E
7530 P8G-2E
6030 P8G-2E
5030 P8G-2E
4030 P8G-2E
9060 P8G-2E
7560 P8G-2E
6060 P8G-2E
5060 P8G-2E
4060 P8G-2E
VAC
120
120
120
120
120
120
120
120
120
120
120
120
120
277
277
277
277
277
277
277
277
277
277
277
277
277
Hz
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Secondary
Volts mA
15000
12000
10500
9000
7500
6000
5000
4000
9000
7500
6000
5000
4000
15000
12000
10500
9000
7500
6000
5000
4000
9000
7500
6000
5000
4000
LED Fault Code
S teady ON
Continuous Flashing
1 - Flash
2 - Flash
3 - Flash
4 - Flash
5 - Flash
30
30
30
30
30
30
30
30
60
60
60
60
60
30
30
30
30
30
30
30
30
60
60
60
60
60
Primary
Input
Wt.
Amp s
Lbs.
VA
435
3.60
21
380
3.15
18
310
2.55
18
285
2.35
13
250
2.10
12
200
1.65
12
170
1.40
12
140
1.15
11
24
4.70
565
21
3.85
460
19
3.10
370
2.60
18
310
265
2.20
13
425
1.55
21
385
1.40
19
310
1.15
19
275
1.00
13
235
.85
12
190
.70
12
160
.60
12
130
.50
11
560
2.05
24
460
1.65
21
385
1.41
20
330
1.20
19
HIGH
240 PO WER
0.87 F A CT
13 OR
Case Dimensions
L
W
H
A
12.13
12.13
12.13
9.22
9.22
9.22
9.22
9.22
12.13
12.13
12.13
12.13
9.22
12.13
12.13
12.13
9.22
9.22
9.22
9.22
9.22
12.13
12.13
12.13
12.13
9.22
4.79
4.79
4.79
3.89
3.89
3.89
3.89
3.89
4.79
4.79
4.79
4.79
3.89
4.79
4.79
4.79
3.89
3.89
3.89
3.89
3.89
4.79
4.79
4.79
4.79
3.89
5.72
5.72
5.72
5.25
5.25
5.25
5.25
5.25
5.72
5.72
5.72
5.72
5.25
5.72
5.72
5.72
5.25
5.25
5.25
5.25
5.25
5.72
5.72
5.72
5.72
5.25
12.23
12.23
12.23
9.87
9.87
9.87
9.87
9.87
12.23
12.23
12.23
12.23
9.87
12.23
12.23
12.23
9.87
9.87
9.87
9.87
9.87
12.23
12.23
12.23
12.23
9.87
B
13.36
13.36
13.36
10.87
10.87
10.87
10.87
10.87
13.36
13.36
13.36
13.36
10.87
13.36
13.36
13.36
10.87
10.87
10.87
10.87
10.87
13.36
13.36
13.36
13.36
10.87
C
D
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
2.0
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
2.0
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
DIAGNOSTIC LED FAULT CODES
Indicates
Operating normally
In Service Mode
15 second Diagnostic & Auto Reset Mode
Secondary Ground Fault with service ground connected
Secondary Ground Fault when service ground not connected
Input V oltage exceeds 120% of rated
Line & Neutral reversed on input connections
xs09001 12/22/2008
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
PBKMA G -51
Indoor/Outdoor Non-weatherproof
Internal Mount Electrode Housing
Junction Box
u UL 2161 Recognized Component
u Primary Junction Box, Allows for Quick and Easy Wiring Without
the Expense of Conduit Fittings and External Junction Box
u Convenient Knock Outs Will Compliment Virtually Any Spacing
Requirement
u Available in 120 Volt - 30 & 60 mA
u Heavy Duty Steel Construction
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
PBKMA G -51
NORMAL POWER FACTOR
Catalog
Number
VAC
Hz
120/277 50/60
Secondary
Volts mA
Primary
VA
Input
Wt
Amp. lbs
L
Case Dimensions
W
H
A
B
* 9030 PBKMAG-51
120
60
9000
30
281
2.34
12
12.28
3.77
3.1
10.78
11.4
v 7530 PBKMAG-51
120
60
7500
30
226
1.88
12
12.28
3.77
3.1
10.78
11.4
v 6030 PBKMAG-51
120
60
6000
30
180
1.5
11
12.28
3.77
3.1
10.78
11.4
v 5030 PBKMAG-51
120
60
5000
30
161
1.34
10
12.28
3.77
3.1
10.78
11.4
v 4030 PBKMAG-51
l 3030 PBKMAG-51
120
120
60
60
4000
3000
30
30
140
101
1.17
0.85
9
9
10.65
10.65
3.77
3.77
3.1
3.1
9.15
9.15
9.78
9.78
9060 PBKMAG-51
120
60
9000
60
540
4.5
22
17.28
3.77
3.48
15.78
16.4
7560 PBKMAG-51
120
60
7500
60
450
3.75
20
17.28
3.77
3.48
15.78
16.4
6060 PBKMAG-51
120
60
6000
60
360
3
16
14
3.77
3.1
12.53
13.15
5060 PBKMAG-51
120
60
5000
60
300
2.5
14
14
3.77
3.1
12.53
13.15
*
*
*
*
* Secondary - Balanced Mid-point Ground
v Secondary - Unbalanced Mid-point Ground
l Secondary - One End Ground
email: [email protected]
xs09024 06/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
PBKMG -34
Outdoor Non-weatherproof
Internal Mount Electrode Housing
u UL 2161 Recognized Component
u Pre-Wired Primary
u No Need for 90o Bends into the Transformer
u Excellent for Self-Contained Letters; Hinged Mounting Simplifies
Installation and Service and Angled Case Corners Allows Minimum
Tube Heights
u Available in 30 & 60 mA
u Heavy Duty Steel Construction
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
PBKMG -34
NORMAL POWER FACTOR
Catalog
Number
* 9030 PBKMG-34
PBKMG-34
PBKMG-34
v 5030 PBKMG-34
v 4030 PBKMG-34
* 9060 PBKMG-34
* 7560 PBKMG-34
* 6060 PBKMG-34
* 5060 PBKMG-34
v 4060 PBKMG-34
v 7530
v 6030
Secondary Primary Input Wt
Volts mA
VA
Amp lbs
9000
7500
6000
5000
4000
9000
7500
6000
5000
4000
270
225
180
160
140
540
450
360
300
240
30
30
30
30
30
60
60
60
60
60
2.34
1.88
1.50
1.34
1.17
4.50
3.75
3.00
2.50
2.00
13
13
12
12
12
25
20
17
16
12
L
12.75
12.75
12.75
12.75
12.75
15.375
17.375
14.125
14.125
12.75
Dimensions in Inches
W H
A
B
3.625
3.625
3.625
3.625
3.625
4.375
3.625
3.625
3.625
3.625
3.25
3.25
3.25
3.25
3.25
3.91
3.25
3.25
3.25
3.25
11.125
11.125
11.125
11.125
11.125
13.375
15.750
12.625
12.625
11.125
12.188
12.188
12.188
12.188
12.188
14.688
16.812
13.562
13.562
12.188
C
1.188
1.188
1.188
1.188
1.188
1.250
1.188
1.188
1.188
1.188
D
2.062
2.062
2.062
2.062
2.062
2.688
2.062
2.062
2.062
2.062
* Secondary - Balanced Mid-point Ground
v Secondary - Unbalanced Mid-point Ground
D
email: [email protected]
xs09022 06/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
PBKMG
Outdoor Non-weatherproof
Back Mount
Electrode Housing
4030 PBKMG & 5030 PBKMG
u UL 2161 Recognized Component
u Pre-wired Primary
u Back Mount Footprint Solves Problems Unique to Your
Needs
u Heavy Duty Steel Construction
u Available in 30 and 60 mA and 120 and 277 V
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
PBKMG
Catalog
Number
VAC
Hz
Outdoor Non-weatherproof
Back Mount
Electrode Housing
Secondary Primary Input Wt
120/277 50/60 Volts
mA
VA
Amp. lbs
Case Dimensions
L
W
H
A
B
C
D
E
F
G
5.0625
*
*
*
15030 PBKMG
120
60
15000
30
450
3.75
23
12.25 6.5625
4.5
10.56
4.5
5.687 4.125
2.5
6
12030 PBKMG
120
60
12000
30
379
3.00
22
12.25
6.56
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
9030 PBKMG
120
60
9000
30
281
2.34
22
12.25
6.56
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
v
7530 PBKMG
120
60
7500
30
226
1.88
15 11.125
4.87
3.75 9.8125 4.5
5.687 4.125 2.4375
6
3.5625
v
6030 PBKMG
120
60
6000
30
180
1.5
14 11.125
4.87
3.75 9.8125 4.5
5.687 4.125 2.4375
6
3.5625
v
5030 PBKMG
120
60
5000
30
161
1.34
13
12
4.375
4.06
10.75 3.75 5.687 4.425
1.75
6
3.125
v
4030 PBKMG
120
60
4000
30
140
1.17
12
12
4.375
4.06
10.75 3.75 5.687 4.425
1.75
6
0
3.125
*
*
*
*
*
*
15060 PBKMG
120
60
15000
60
890
7.42
42
14.25
7.87
5.298 12.56
5.5
7.125 5.125
2.5
6.687
6.125
12060 PBKMG
120
60
12000
60
720
6
40
14.25
7.87
5.298 12.56
5.5
7.125 5.125
2.5
6.687
6.125
9060 PBKMG
120
60
9000
60
540
4.5
29
12.25
6.56
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
7560 PBKMG
120
60
7500
60
450
3.75
23
12.25
6.56
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
6060 PBKMG
120
60
6000
60
360
3
23
12.25
6.56
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
5060 PBKMG
120
60
5000
60
300
2.5
20
12.25
6.56
4.5
10.56
4.5
v
4060 PBKMG
120
60
4000
60
240
2
16 11.125 4.875
3.75
*
*
*
15030 PBKMG
277
60
15000
30
450
1.63
26
12.25 6.5625
12030 PBKMG
277
60
12000
30
379
1.30
25
12.25
6.56
9030 PBKMG
277
60
9000
30
281
1.01
25
12.25
6.56
*
*
*
15060 PBKMG
277
60
15000
60
890
3.22
45
14.25
12060 PBKMG
277
60
12000
60
720
2.60
43
14.25
9060 PBKMG
277
60
9000
60
540
1.95
32
12.25
6.56
* Secondary - Balanced Mid-point Ground
v Secondary - Unbalanced Mid-point Ground
5.687
6
3.9375
6
5.0625
9.812 4.25
5.24
3.812
1.75
4.125
3.562
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
4.5
10.56
4.5
5.687 4.125
2.5
6
5.0625
7.87
5.298 12.56
5.5
7.125 5.125
2.5
6.687
6.125
7.87
5.298 12.56
5.5
7.125 5.125
2.5
6.687
6.125
4.5
5.687 4.125
2.5
6
5.0625
4.5
10.56
ALL DIMENSIONS IN INCHES.
This drawing applies only to the 4030 and 5030 PBKMG.
email: [email protected]
xs09021 06/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
PBKMG -51
PBKMCG -51
Indoor/Outdoor Non-weatherproof
Internal Mount Electrode Housing
u UL 2161 Recognized Component
u Pre-Wired Primary
u Available in 30 and 60 mA, 120 and 277 V, Normal and High Power
Factor (12000 and 15000 available only in 30 mA)
u Heavy Duty Steel Construction
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
NORMAL POWER FACTOR
Catalog
Number
VAC
15030 PBKMG-51
12030 PBKMG-51
9030 PBKMG-51
7530 PBKMG-51
6030 PBKMG-51
5030 PBKMG-51
4130 PBKMG-51
3030 PBKMG-51
120
120
120
120
120
120
120
120
120
120
120
120
120
120
277
277
277
277
277
277
277
277
277
277
277
277
9060 PBKMG-51
7560 PBKMG-51
6060 PBKMG-51
5060 PBKMG-51
4060 PBKMG-51
3060 PBKMG-51
15030 PBKMG-51
12030 PBKMG-51
9030 PBKMG-51
7530 PBKMG-51
6030 PBKMG-51
5030 PBKMG-51
4130 PBKMG-51
9060 PBKMG-51
7560 PBKMG-51
6060 PBKMG-51
5060 PBKMG-51
4060 PBKMG-51
Catalog
Number
VAC
9030 PBKMCG-51
7530 PBKMCG-51
6030 PBKMCG-51
5030 PBKMCG-51
4030 PBKMCG-51
4130 PBKMCG-51
120
120
120
120
120
120
120
120
120
120
120
277
277
277
277
9060 PBKMCG-51
7560 PBKMCG-51
6060 PBKMCG-51
5060 PBKMCG-51
4060 PBKMCG-51
9060 PBKMCG-51
7560 PBKMCG-51
6060 PBKMCG-51
5060 PBKMCG-51
Secondary
Volts mA
15000 30
12000 30
9000 30
7500 30
6000 30
5000 30
4000 30
3000 30
9000 60
7500 60
6000 60
5000 60
4000 60
3000 60
Pri Input SECONDARY Wt.
Hz
VA Volts GROUND Lbs.
L
W
450 3.75 BMPG 20 11.500 5.130
60
360 3.00 BMPG 20 11.500 5.130
60
280 2.34 BMPG 12 10.125 3.776
60
225 1.88 UMPG 12 10.125 3.776
60
180 1.50 UMPG 11 10.125 3.776
60
160 1.34 UMPG 11 10.125 3.776
60
140 1.17 UMPG
8.500 3.776
9
60
100
8.500
OEG
9
.85
60
3.776
540 4.50 BMPG 21 15.125 3.766
60
450 3.75 BMPG 21 15.125 3.766
60
60
360 3.00 BMPG 15 11.875 3.766
60
300 2.50 BMPG 15 11.875 3.766
60
240 2.00 UMPG 11 10.125 3.766
60
180 1.50 UMPG 11 10.125 3.766
60 15000 30 450 1.63 BMPG 20 11.500 5.130
60 12000 30 360 1.30 BMPG 20 11.500 5.130
60 9000 30 280 1.01 BMPG 12 10.125 3.766
.81 UMPG 12 10.125 3.766
60 7500 30 225
60 6000 30 190
.69 UMPG 11 10.125 3.766
.58 UMPG 10 10.125 3.766
60 5000 30 160
60 4000 30 140
8.500 3.766
.51 UMPG
9
60 9000 60 540 1.95 BMPG 21 15.125 3.766
60 7500 60 420 1.63 BMPG 21 15.125 3.766
60 6000 60 370 1.34 BMPG 15 11.875 3.766
60 5000 60 300 1.08 BMPG 15 11.875 3.766
.87 UMPG 11 10.125 3.766
60 4000 60 240
HIGH POWER FACTOR
Secondary PRI Input SECONDARY Wt.
Hz
GROUND
Lbs.
L
Volts mA VA Amps
W
60 9000 30 150 1.25 BMPG 13 11.875 3.625
60 7500 30 125 1.05 UMPG 13 11.875 3.625
.84 UMPG 13 11.875 3.625
60 6000 30 100
60 5000 30
90
.75 UMPG 13 11.875 3.625
75
.63 UMPG 12 10.125 3.625
60 4000 30
75
60 4100 30
.63 OEG 10 10.125 3.625
60 9000 60 250 2.50 BMPG 23 16.750 3.625
60 7500 60 300 2.09 BMPG 22 16.750 3.625
60 6000 60 200 1.67 BMPG 20 13.500 3.625
60 5000 60 170 1.42 BMPG 20 13.500 3.625
60 4000 60 135 1.13 UMPG 13 11.875 3.625
60 9000 60 250 1.09 BMPG 23 16.750 3.625
60 7500 60 300
.91 BMPG 22 16.750 3.625
60 6000 60 200
.73 BMPG 20 13.500 3.625
60 5000 60 170
.62 BMPG 20 13.500 3.625
Case Dimensions
H
4.178
4.178
3.080
3.080
3.080
3.080
3.080
3.080
3.447
3.447
3.080
3.080
3.080
3.080
4.178
4.178
3.080
3.080
3.080
3.080
3.080
3.447
3.447
3.080
3.080
3.080
A
10.000
10.000
8.625
8.625
8.625
8.625
7.000
7.000
13.625
13.625
10.375
10.375
8.625
8.625
10.000
10.000
8.625
8.625
8.625
8.625
7.000
13.625
13.625
10.375
10.375
8.625
B
10.625
10.625
9.250
9.250
9.250
9.250
7.620
7.620
14.250
14.250
11.000
11.000
9.250
9.250
10.625
10.625
9.250
9.250
9.250
9.250
7.620
14.250
14.250
11.000
11.000
9.250
C
2.5
2.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
D
2.5
2.5
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
E
1.5
1.5
1.3
1.3
C
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
D
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
E
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
Case Dimensions
H
3.080
3.080
3.080
3.080
3.080
3.080
3.447
3.447
3.072
3.072
3.080
3.447
3.447
3.072
3.072
A
10.375
10.375
10.375
10.375
8.625
8.625
B
11.000
11.000
11.000
11.000
9.250
9.250
15.250
15.250
12.000
12.000
10.375
15.250
15.250
12.000
12.000
15.875
15.875
12.625
12.625
11.000
15.875
15.875
12.625
12.625
BMPG = Balance Mid-Point Ground
UMPG = Unbalanced Mid-point Ground
OEG = One End Ground
H
A
FRANCEFORMER
.50 x .25 SLOT
4 PLCS
D
W C
E
Mounting
2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062
voice 800-753-2753 w fax 615-799-3199
B
L
xs09013 5/12/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
PBKMG -751
PBKMG -734
Outdoor Non-weatherproof
Mini Internal Mount
Electrode Housing
PBKMG -734
PBKMG -751
u UL 2161 Recognized Component
u Pre-wired Primary
u Ideal for Shallow Profile Individual Self-Contained Letters
u Small Case Size Allows for Small Spaces
u Available in 2 Styles - 751 & 734
u Heavy Duty Steel Construction
www.franceformer.com
2268 Fairview Blvd
Click here to unlock PDFKit.NET
PO Box 300
Fairview, TN 37062
voice 800-753-2753
fax 615-799-3199
Generated by PDFKit.NET Evaluation
Non-weatherproof
PBKMG -751 Outdoor
Mini Internal Mount
Electrode Housing
PBKMG -734
NORMAL POWER FACTOR
Catalog
Number
v
v
l
v
v
l
Secondary
Volts mA
5000
4000
3000
5000
4000
3000
5030 PBKMG-734
4030 PBKMG-734
3030 PBKMG-734
5030 PBKMG-751
4030 PBKMG-751
3030 PBKMG-751
30
30
30
30
30
30
Primary Input Wt
VA Amp lbs
7
7
7
7
7
7
1.34
1.17
85
1.34
1.17
.85
160
140
100
160
140
100
Dimensions in Inches
L
W
H
A
7.75
7.75
7.75
7.00
7.00
7.00
2.937
2.937
2.937
2.828
2.828
2.828
2.875
2.875
2.875
3.000
3.000
3.000
6.750
6.750
6.750
5.800
5.800
5.800
B
7.250
7.250
7.250
6.314
6.314
6.314
v Secondary - Unbalanced Mid-point Ground
l Secondary - One End Ground
PBKMG -734
PBKMG -751
A
1.0”
H
H
2.0”
1.0”
L
B MTG
L
B
MTG
2.0”
W
1 1/2”
1 1/2”
2.0”
W
5/16” DIA
4 HOLES
DIM TO CENTER
OF ELECTRODES
5/16” X 1/2”
4 SLOTS
1.0”
A
email: [email protected]
xs09023 06/02/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
The Power and the Light
Save Time
Simplify Production
Sign Bright from France
is recognized by sign
builders everywhere as
the best solution for HID
sign illumination. This outof-the-box solution is
convenient and affordable
and will save time and
energy on the factory floor.
Time Saving
We’ve done the work for you by pre-assembling
the ballast, lampholder and diffuser in one
convenient kit. All components are pre-wired
to an integrated wiring compartment.
Production Ready
The Sign Bright is ready when you are. No
more coordinating multiple components to
come together on the factory floor for
production. One part number assures you
have everything you need, when you need it.
Sign Ready
High performance output with both 250W
and 400W units, your sign illuminate evenly
and deliver the lumen output your customer
wants. The build in diffuser assures you get
even light distribution.
Click here to unlock PDFKit.NET
www.franceformer.com
Generated by PDFKit.NET Evaluation
Sign Bright
Line Current (A)
Catalog &
Part Number
SBIP-250
18264
SBIP-400
18265
Watts Imput Power Operating
Voltage Factor
250
120
208
240
277
400
120
208
240
277
Output
Output Open
Circuit
Output Short
Circuit
Open Circuit
Voltage
Short Circuit
Current
Capacitor
(uF/V)
Wt.
Lbs.
>.85
2.50
1.45
1.25
1.10
2.65 - 3.25
1.35 - 1.80
1.15 - 1.50
1.00 - 1.35
0.75 - 1.55
0.40 - 1.00
0.40 - 0.80
0.30 - 0.70
280 - 340
2.25 - 2.75
15/400
18
>.85
4.00
2.30
2.00
1.70
2.50 - 3.80
1.60 - 2.30
1.50 - 2.10
1.20 - 1.75
1.75 - 3.25
1.00 - 1.85
0.70 - 1.50
0.65 - 1.40
270 - 330
3.50 - 4.30
24/400
20
The minimum recommended sign cabinet depth is 30” for SBIP and 36” for SBIP-400.
For optimum heat dissipation, the recommended mounting is with lamp vertical as shown below. The lamps supplied are universal mount, but orienting any
other direction could reduce the life of the ballast.
The recommended horizontal and vertical lamp spacing is 4'0" for the SB400 and 3'0" for the SB250. Actual spacing may vary depending on cabinet size,
cabinet depth, face substrate, face decoration and light output requirements.
The Sign Bright case must be mounted on a steel member capable of supporting 20 lb. dead load.
The 120 & 277 Volt leads are supplied in the writing compartment. The 208 and 240 Volt leads are provided in the ballast compartment and must be routed to
the wiring compartment by the end user.
xs09030 07/08/09
2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
Fluorescent Lampholders
For T12 Lamps
WP-LH30-1
WP-LH82
WP-LH83
WP-LH30-2
For T8 Lamps
WP-LH30-1BP
WP-LH82BP
w Rated 1000V/660 Watt for T8 & T12 Lamps
WP-LH82BP, WP-LH30-2,
w WP-LH82,
WP-LH30-2BP are Stationary Mount
WP-LH83BP, WP-LH30-1,
w WP-LH83,
WP-LH30-1BP are Spring Loaded
12” leads - 18 Awg/Awm - 1000V
w Standard
Stranded, stripped and pre-tinned.
w 90°C Maximum end use application
WP-LH83BP
WP-LH30-2BP
material is Lexan w Housing
(UV resistance & flame retardent)
quality Stainless Steel
w High
Spring on WP-LH83, WP-LH83BP,
WP-LH30-1 & WP-LH-301BP
w High strength metal retaining clips
w Packaged - 250 per box
www.westrimproducts.com
xs09034 10/22/09
2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-423-1369 w fax 615-799-3199
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5KA2NG -2UE ServiceMaster
Universal Replacement
Service Units
Ever wish you
had 8 arms?
With the “ServiceMaster”
you only need 2!
True 30mA Output- The “ServiceMaster”
can replace 8 ratings.
Diagnostic Circuit- “LED” indicates
the reason for service, allowing for
quick, easy troubleshooting.
Primary Wiring Requirements of a
Non-SCGFP - with the added safety
of Secondary Ground Fault Protection.
Service Button - For easy
troubleshooting of ground faults and
primary wiring problems. Overrides
the SCGFP for up to 30 minutes.
Auto Reset - After secondary ground
fault, automatically attempts to reset
three times within ten seconds. Manual
reset possible at any time by
disconnecting primary power.
Secondary Circuit Ground Fault
Protection - (SCGFP) Disables unit
upon detection of arcs to ground in
compliance with UL2161 and NEC
requirements.
Easy Wiring Methods - Virtual
Ground and Series Wiring Methods
User Friendly - Adapts to most
grounding situations.
Features Include- Easy to carry
handle; On/Off Toggle Switch; No
transformer box required for interior
installations.
*Can be used in flashing/dimming
applications.
*UL does not have listing requirements for transformers that are
rdemotely dimmed or flashed.
www.franceformer.com
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
P5KA2NG -2UE ServiceMaster
SERVICE
MASTER
REPLACES
15000, 12000 & 10500 Volt
9000, 7500, 6000, 5000, 4000, 3000 & 2000 Volt
15030 P5KA2NG-2UE
9030 P5KA2NG-2UE
Diagnostic LED Operation
DIAGNOSTIC LED OPERATION
Indicates
LED Fault Code
Steady ON
Continuous Flashing
1 - Flash
2 - Flash
3 - Flash
4 - Flash
5 - Flash
Operating normally
In Service Mode
15 second Diagnostic & Auto Reset Mode
Secondary Ground Fault with service ground connected
Secondary Ground Fault when service ground not connected
Input Voltage exceeds 120% of rated
Line & Neutral reversed on input connections
Service Switch does not
operate without proper grounding.
A
W
NO PCB
“LED"
INDICATOR
Toggle
Switch
20 amp 120V
.940
ON
OFF
1.49
H
Service
Button
3.35
L
B
(MTG)
C
.375 X .750
SLOT, 4 PLCS
Catalog
Number
VAC
Hz
15030 P5KA2NG-2UE
9030 P5KA2NG-2UE
15030 P5KA2NG-2UE
9030 P5KA2NG-2UE
120
120
277
277
60
60
60
60
NORMAL POWER
FACTOR
NORMAL
POWER
FACTOR
Secondary Primary Input
Wt.
Amps Lbs.
V.A.
Volts mA
L
15000
9000
15000
9000
30
30
30
30
510
330
530
320
4.25
2.75
1.90
1.15
25
17
25
17
13.35
13.35
13.35
13.35
W
Case Dimensions
H
A
B
C
7.47
7.47
7.47
7.47
12.21
12.21
12.21
12.21
3.00
3.00
3.00
3.00
4.50
4.50
4.50
4.50
10.87
10.87
10.87
10.87
2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-753-2753 w fax 615-799-3199
xs09002 04/29/09
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
EB25-120/277V
EB45-120V
EB45-277V
EB65-120V
EB65-277V
T8 BALLASTS
S P E C I F I C A T I O N S
INPUT PARAMETERS
2-LAMP
4 -LAMP
6-LAMP
E B 2 5 - 12 0 V / 2 7 7 V
E B45-120V
EB45-277V
EB65-120V
EB65-277V
Nominal line voltage rating
120 – 277 volts
120 volts
277 volts
120 volts
277 volts
Line voltage operating range
90 – 132 volts
90 – 132 volts
208 – 305 volts
90 – 132 volts
208 – 305 volts
Maximum input current
.90 A
1.50 A
.65 A
2.60 A
1.20 A
Power factor
>90%
>90%
>90%
>90%
>90%
Total harmonic distortion
<10%
<10%
<10%
<10%
<10%
FCC CFR Part 18 for
RF Lighting Device.
Non-consumer equipment
FCC CFR Part 18 for
RF Lighting Device.
Non-consumer equipment
FCC CFR Part 18 for
RF Lighting Device.
Non-consumer equipment
FCC CFR Part 18 for
RF Lighting Device.
Non-consumer equipment
FCC CFR Part 18 for
RF Lighting Device.
Non-consumer equipment
>90%
>90%
>90%
>90%
>90%
EMI requirements
Electrical efficiency
(at full load)
Click here to unlock PDFKit.NET
2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com
Generated by PDFKit.NET Evaluation
S P E C I F I C A T I O N S
EB25-120/277V
•
EB45-120V
•
EB45-277V
•
EB65-120V
2- LAM P
4- LA MP
E B 2 5 - 12 0 V / 2 7 7 V
E B45-120V • EB45-277V
RMS open circuit voltage
Less than 1000 volts
Less than 1000 volts
Less than 1000 volts
Minimum/Maximum lamp load
3–10 ft
( e.g. 1 or 2 lamps )
6 – 20 ft
( e.g. 3 or 4 lamps )
10 – 30 ft
( e.g. 5 or 6 lamps )
Parallel
Parallel
Parallel
Min. lamp length on any one output
3 ft
2 ft
2 ft
Max. lamp length on any one output
5 ft
5 ft
5 ft
-20° F (-29 °C)
-20° F (-29 °C)
-20° F (-29 °C)
No
No
No
Height
1.2 inches
1.8 inches
1.8 inches
Width
1.625 inches
2.625 inches
2.625 inches
Length
9.438 inches
10.2 inches
14.25 inches
Weight
1.50 lb
3.30 lb
5.05 lb
Painted steel, white
Painted steel, white
Painted steel, white
1 Black, 1 White, each 2 feet long
1 Black, 1 White, each 2 feet long
1 Black, 1 White, each 2 feet long
1 red common, 2 corresponding
blue, each AWG 18 solid,
8 feet out of case
2 blue, 2 red with two yellow
commons, each AWG 18 solid,
10 feet out of case
3 blue with corresponding yellow
common, 3 red with corresponding
yellow/black common, each
AWG 18 solid, 12 feet out of case
cULus
cULus
cULus
Operating temperature range
-30° to 65°C
-30° to 65°C
-30° to 65°C
Storage temperature
-30° to 85°C
-30° to 85°C
-30° to 85°C
OUTPUT PARAMETERS
Lamps configuration
Low temperature starting
Externally dimmable
Enclosure material
Input leads
Output leads
Agency certifications
Warranty
6-LA MP
•
EB65-277V
COMM EN TS
EB65-120V • EB65-277V
Includes base plate. Reference only
Outdoor Type 2
France warrants the Reliant ballasts to be free from defects in manufacturing and workmanship for a period of four years
from the date of manufacture. When used with Westrim T8 lamp holders, France warrants the product for five (5) years.
xs09011 05/01/06
Click here to unlock PDFKit.NET
2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com
Generated by PDFKit.NET Evaluation
INTRODUCING
THE FRANCE T8 RELIANT
FLUORESCENT
LIGHTING SYSTEM
10 YEAR LIFE EXPECTANCY
Up to 4 times longer life than standard T12 lamps, based on
a normal-duty cycle usage of 12 hours per day.
VIRTUALLY ELIMINATES SERVICE CALLS
Save hundreds of dollars in service calls for lamp replacements.
Three fewer service calls at $125 each for replacements
equals a savings of $375 per sign.
HEAVY-DUTY T8 LAMP SOCKETS
Specially designed for the sign industry, the T8 Reliant
lamp sockets are interchangeable with T12 standard sockets
for easy retrofitting of existing signs.
UNIQUE SIGN LENGTH LAMPS
The T8 Reliant lamps come in the same length as standard
T12 HO, making it easy to retrofit T12 applications.
PATENTED LIGHT DIFFUSION
The T8 Reliant lamp features light diffusion in the outer tube
for closer spacing of lamps to the face without hot spots.
Fewer T8 lamps required due to spacing on 18” centers
compared to 12” centers for T12 lamps. Cabinet depth can be
reduced by 2”.
COLD CLIMATE CHARACTERISTICS
Patented Cold Climate CC products assure starting and superior light output at temperatures as
low as -30L C (20L F).
HIGH-ENERGY EFFICIENT T8 DESIGN
Uses up to 30% less energy than T12 HO lamps, providing a payback on energy efficiency in about
one year.
ENVIRONMENTALLY FRIENDLY
Up to 90% less mercury to depose of during product life cycle.
Uses 1/3 less mercury per lamp with 4 times longer life using 1/3
fewer lamps.
TRUE COLOR RENDERING
Excellant color rendering index of 80-85 CRI.
T8 Reliant
Click here to unlock PDFKit.NET
®
Generated by PDFKit.NET Evaluation
F luor escent
T8 Lamps
T8 Reliant Fluorescent Lamps - 4500K White Plus CRI - 85
Catalog #
* F24 T8 - LL / WP
F36 T8 - LL / WP
F48 T8 - LL / WP
F60 T8 - LL / WP
F72 T8 - LL / WP
F84 T8 - LL / WP
F96 T8 - LL / WP
Description
24” T8 Fluorescent Lamp Long Life
36” T8 Fluorescent Lamp Long Life
48” T8 Fluorescent Lamp Long Life
60” T8 Fluorescent Lamp Long Life
72” T8 Fluorescent Lamp Long Life
84” T8 Fluorescent Lamp Long Life
96” T8 Fluorescent Lamp Long Life
White Plus
White Plus
White Plus
White Plus
White Plus
White Plus
White Plus
Watts
18
24
32
40
48
56
64
* F24 T8 Lamps are 1 3/8” longer than sign length T12 HO Lamps. All other Lamps use sign length spacings.
T8 Reliant Fluorescent Lamps - 6500K Daylight CRI - 85
Catalog #
* F24 T8 - LL / DL
F36 T8 - LL / DL
F48 T8 - LL / DL
F60 T8 - LL / DL
F72 T8 - LL / DL
F84 T8 - LL / DL
F96 T8 - LL / DL
Description
24” T8 Fluorescent Lamp Long Life
36” T8 Fluorescent Lamp Long Life
48” T8 Fluorescent Lamp Long Life
60” T8 Fluorescent Lamp Long Life
72” T8 Fluorescent Lamp Long Life
84” T8 Fluorescent Lamp Long Life
96” T8 Fluorescent Lamp Long Life
Daylight
Daylight
Daylight
Daylight
Daylight
Daylight
Daylight
Watts
18
24
32
40
48
56
64
T8 Reliant Fluorescent Lamps - 4500K White Plus CRI - 85
Catalog #
Description
Watts
* F24 T8 - CC / WP
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate
Cold Climate
Cold Climate
Cold Climate
* F24 T8 - CC DA/WP
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
White Plus
White Plus
White Plus
White Plus
18
24
32
40
* F24 T8 - CC DB/WP
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
White Plus
White Plus
White Plus
White Plus
18
24
32
40
F36 T8 - CC / WP
F48 T8 - CC / WP
F60 T8 - CC / WP
F36 T8 - CC DA/WP
F48 T8 - CC DA/WP
F60 T8 - CC DA/WP
F36 T8 - CC DB/WP
F48 T8 - CC DB/WP
F60 T8 - CC DB/WP
White Plus Non-Diffused
White Plus Non-Diffused
White Plus Non-Diffused
White Plus Non-Diffused
18
24
32
40
*F24 T8 Lamps are 1 3/8” longer than sign length T12 HO Lamps.
All other Lamps use sign length spacings.
Catalog #
T8 Reliant Fluorescent Lamps - 6500K Daylight CRI - 85
Description
Watts
* F24 T8 - CC / DL
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate
Cold Climate
Cold Climate
Cold Climate
* F24 T8 - CC DA/DL
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
Cold Climate Dual Diffusion Type A
Daylight
Daylight
Daylight
Daylight
18
24
32
40
* F24 T8 - CC DB/DL
24” T8 Fluorescent Lamp
36” T8 Fluorescent Lamp
48” T8 Fluorescent Lamp
60” T8 Fluorescent Lamp
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
Cold Climate Dual Diffusion Type B
Daylight
Daylight
Daylight
Daylight
18
24
32
40
F36 T8 - CC / DL
F48 T8 - CC / DL
F60 T8 - CC / DL
F36 T8 - CC DA/DL
F48 T8 - CC DA/DL
F60 T8 - CC DA/DL
F36 T8 - CC DB/DL
F48 T8 - CC DB/DL
F60 T8 - CC DB/DL
Daylight Non-Diffused
Daylight Non-Diffused
Daylight Non-Diffused
Daylight Non-Diffused
18
24
32
40
The Power and the Light
Click here to unlock PDFKit.NET
Generated by PDFKit.NET Evaluation
T12
EL ECT R O N I C
S I G N
EB1228-120V
EB1228-277V
EB1248-120V
EB1248-277V
EB1268-120V
EB1268-277V
B A LL A S T
S P E C I F I C A T I O N S
INPUT PARAMETERS
2-LAMP
4 -LAM P
6-LAMP
12 0 V
277V
120V
277V
120V
277V
Nominal line voltage rating
120 volts, 50/60 Hz
277 volts, 50/60 Hz
120 volts, 50/60 Hz
277 volts, 50/60 Hz
120 volts, 50/60 Hz
277 volts, 50/60 Hz
Line voltage operating range
90 to 132 volts
208 to 305 volts
90 to 132 volts
208 to 305 volts
90 to 132 volts
208 to 305 volts
Nominal input current
1.2A
.6A
2.2A
1.0A
4.0A
1.7 A
Power factor
>90%
>90%
>90%
>90%
>90%
>90%
Total harmonic distortion
<10%
<10%
<10%
<10%
<10%
<10%
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
FCC 47 CFR Part 18 for
RF Lighting Device, Nonconsumer equipment
>90%
>90%
>90%
>90%
>90%
>90%
EMI requirements
Electrical efficiency
(at full load)
Click here to unlock PDFKit.NET
2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com
Generated by PDFKit.NET Evaluation
S P E C I F I C A T I O N S
EB1228-120V • EB1228-277V • EB1248-120V • EB1248-277V • EB1268-120V • EB1268-277V
2 -LAM P
4-LAMP
6-LAMP
RMS open circuit voltage
Less than 1000 volts
Less than 1000 volts
Less than 1000 volts
Minimum/Maximum lamp load
2 –16 ft
( e.g. 1 or 2 lamps )
6–32 ft
( e.g. 3 or 4 lamps )
6–48 ft
( 3, 4, 5 or 6 lamps )
Parallel
Parallel
Parallel
Min. lamp length on any one output
2 ft
2 ft
2 ft
Max. lamp length on any one output
8 ft
8 ft
8 ft
-20° F (-29 °C)
-20° F (-29 °C)
-20° F (-29 °C)
No
No
No
Height
1.8 inches
1.8 inches
1.8 inches
Reference only
Width
2.6 inches
2.6 inches
2.6 inches
Reference only
Length
10.25 inches
14.25 inches
14.25 inches
Includes base plate. Reference only
1.5 lb
2.5 lb
2.5 lb
Painted steel, white
Painted steel, white
Painted steel, white
1 Black, 1 White, each 2 feet long
1 Black, 1 White, each 2 feet long
1 Black, 1 White, each 2 feet long
1 red common, 2 corresponding
blue, each AWG 18 solid,
8 feet out of case
2 blue with corresponding yellow
common, 2 red with corresponding
yellow/black common, each AWG
18 solid, 10 feet out of case
3 blue with corresponding yellow
common, 3 red with corresponding
yellow/black common, each AWG
18 solid, 12 feet out of case
cULus
cULus
cULus
Operating temperature range
-30° to 65°C
-30° to 65°C
-30° to 65°C
Storage temperature
-30° to 85°C
-30° to 85°C
-30° to 85°C
Lamps configuration
Low temperature starting
Externally dimmable
Total weight
Enclosure material
Input leads
Output leads
Agency approvals
Warranty
C OMMENT S
Less than 600 volts to ground –
may use 600 volt ballast wire
Outdoor Type 1
France warrants the Powerbrite ballasts to be free from defects in manufacturing and workmanship for a period of four years
from the date of manufacture. When used with Westrim T12 lamp holders, France warrants the product for five (5) years.
xs09012 02/01/06
Click here to unlock PDFKit.NET
2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com

Similar documents