Cut Sheet - Myers Power Products

Transcription

Cut Sheet - Myers Power Products
SEISMIC CATALOG
ALSO AVAILABLE FROM MYERS POWER PRODUCTS:
ILLUMINATOR E-H/IE-H & ILLUMINATOR CIII-H
Illuminator Series E/IE
Single Phase
1.5kVA/kW to 16.7kVA/kW
Illuminator Series CIII
Three Phase
4.8kVA/kW to 50kVA/kW
UL-924 Listed
Emergency Lighting
and Power Equipment
1.5kVA/kW to 16.7kVA/kW Single Phase
4.8kVA/kW to 50kVA/kW Three Phase
65kAIC Rated
Shaker Table Tested to SDS Level 2.5
Illuminator Series EM
Single Phase
1kVA/kW to 2.8kVA/kW
Listed to CBC2010, IBC2009, AC156
44 S. Commerce Way
Bethlehem, PA 18017
Phone: (610) 868-3500
Fax: (610) 868-8686
www.myerspowerproducts.com
Illuminator Series CR/DR
Single and Three Phase
Outdoor System 3kVA/kW to 8kVA/kW
ELP-0008-DS-1212
98% Efficient
SYSTEM SPECIFICATIONS
THE ILLUMINATOR -H SEISMIC SERIES
The Illuminator Series E/IE-H and CIII-H are the latest innovation in Emergency Lighting Inverter
technology. The Illuminator -H series is Myers’ shaker table tested and approved expansion to the
industry leading Central Emergency Lighting inverters.
INPUT
Voltage
Input Power Walk-in
Input Frequency
Synchronizing Slew Rate
Protection
AIC Rating
Power Factor
These systems meet the requirements of CBC 2010 and IBC 2009 and have been shaker table
tested in accordance with ICC-ES-AC-156 procedures to an SDS level of 2.5g. In addition they
have received OSHPD (California Office of Statewide Health Planning and Development) Special
Seismic Certification. This is the most rigid seismic standards currently being specified.
SEISMIC SYSTEMS E-H, IE-H, CIII-H
OUTPUT
Voltage
Dynamic Voltage
Harmonic Distortion
Overload
Output Frequency
Load Power Factor
Inverter Overload
Illuminator E-H
The Illuminator Series E-H single phase uninterruptible system features sizes from 1.5-16.7
kVA/kW. This fast transfer system is designed to support all types of fixtures in emergency
applications including HID, LED, and fluorescent. In addition this system can support mixed loads
of all different types. The line interactive design eliminates excessive transfers to battery power.
The Illuminator Series E-H transfers to inverter mode (battery power) within 2ms of loss of utility
power in order to maintain the arc of an HID light.
Protection
Crest Factor
Illuminator CIII-H
Type
Charger
Protection
Disconnect
Optional Runtimes
Altitude
Operating Temperature
Storage Temperature
Relative Humidity
•
1
< 10,000 feet (above sea level) without derating.
Inverter: 0° to 40°C (32° to 104°F); Battery: 20° to 30°C (68° to 86°F) per UL 924.
-20° to 70°C (-4° to 158°F) (electronics only).
< 95% (non-condensing).
GENERAL
Efficiency
Design
Output Circuits
Generator Input
Control Panel
STANDARD FEATURES Illuminator E/IE-H
UL 924 Listed
98% Efficient
PWM/IGBT Technology
Micro-processor Control
User Programmable Front Meter Panel
Automatic Selt-test, Event and Alarm Logs
OSHPD Special Seismic Certification
No. OSP-0305-10
High Crest Factor
Valve-regulated, sealed lead-calcium.
Microprocessor controlled and temperature compensating; recharge per UL 924 spec.
Automatic low-battery disconnect; automatic restart upon utility return.
Series E-H / IE-H and Series CIII-H, 4.8-16.7k fuse(s);
Series CIII-H, 24-50k circuit breaker / fuse(s).
Extended run times available. Consult factory for additional information.
ENVIRONMENTAL
The Illuminator Series CIII-H three phase uninterruptible system features sizes from 4.8 to 50
kVA/kW. As with Myers’ other uninterruptible systems the CIII-H series is designed to support all
lamp sources including HID and LED. Its large capacity is perfect for larger industrial and
commercial applications. It can also help to provide load balancing within a facility with its wide
range of sizes.
•
•
•
•
•
•
•
120 or 277VAC, 1-phase, 2-wire + G (Series E-H / IE-H).
120/208 or 277/480VAC, 3-phase, 4-wire + G (Wye or Delta) (Series CIII-H).
Contact factory for all other voltages.
+/- 2% for +/-25% load step change, recovery within 3 cycles.
< 3% THD for linear load.
Fuse protected.
60Hz +/- 0.05Hz during emergency mode.
0.5 lag to 0.5 lead.
115% for 10 minutes; 125% for 5 minutes; 280% for 16 line cycles (Series E-H / IE-H);
280% for 12 line cycles (Series CIII-H).
Series E-H / IE-H - main or distribution circuit breaker(s).
Series CIII-H - optional main circuit breaker.
2.8
BATTERY
Illuminator IE-H
The Illuminator Series IE-H single phase standard transfer system features sizes from 1.5-16.7
kVA/kW; it is designed to support all lighting loads except HID. This includes LED, fluorescent,
incandescent and quartz fixtures. This system comes standard with normally on and normally off
(emergency only) outputs.
120 or 277VAC (+10% / -20%), 1-phase, 2-wire + G (Series E-H).
120 or 277VAC (+10% / -15%), 1-phase, 2-wire + G (Series IE-H).
120/208 or 277/480VAC (+10% / -15%), 3-phase, 4-wire + G (Wye) (Series CIII-H).
Contact factory for all other voltages.
Limiting inrush current to less than 125% of full rated load; 10 times for 1 line cycle.
60Hz, +/- 3%.
1Hz per second nominal.
Input Circuit Breaker.
65k RMS symmetrical ampere short-circuit rating.
0.5 lag/lead.
•
•
•
•
•
•
•
•
Input Main Circuit Breaker
True Output Sine Wave
Meets NFPA-101 for self-testing and selfdiagnostics
Low Audible Noise 45Dba
Modular Design
Load Reduction Fault
Air Filters not required
65 kAIC rating
Metering
Alarms
Communications
Manual Maintenance Bypass
Alarm Contacts
Warranty
Factory Start-up
5-Year Maintenance Plan
98%.
Standby UPS; PWM inverter type utilizing IGBT technology with 2ms transfer time on
Series CIII-H and Series E-H and 50ms on Series IE-H.
Series E-H - Normally On Circuit standard; Normally Off Circuit optional.
Series IE-H - Normally On and Normally Off Circuits standard.
Series CIII-H - Normally On Circuit standard; Normally Off Circuit optional.
Compatible with generators.
Microprocessor controlled with user friendly display, touchpad controls/functions and
system status indications.
Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA,
Temperature, Inverter Wattage.
High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction
Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature,
Inverter Fault, Output Fault, Test Failure, and Optional Circuit Breaker Trip.
RS-232 port (DB9 standard). See ordering guide for additional available options.
Standard internal on Series CIII-H; optional internal on Series E-H / IE-H. Make before break.
Optional summary alarm and / or status monitoring form "C" contacts.
1 year standard warranty includes all parts, labor & travel expenses within the
48 contiguous states. 10 years prorated warranty on batteries. Extended warranties, preventative maintenance and
customized service plans are available.
Purchase factory start-up & receive 1 additional year of electronics warranty.
Purchase 5-year preventative maintenance plan & receive free factory start-up.
PHYSICAL
Cabinet
Cooling
Cable Entry
Access
Freestanding NEMA Type 1; reinforced and approved for seismic withstand.
Forced air during emergency. Convection cooled during normal operation. No filters required.
Series E-H / IE-H: top or sides on 1.5 - 5kVA; sides only on 6 - 16.7kVA.
Series CIII-H: top, bottom or sides.
Front ONLY is required.
6
ILLUMINATOR E/IE-H SINGLE PHASE
ORDERING GUIDE
Example Model Number
1-DH-4-S-C3001-C-I-S-2YW
SYSTEM TYPE
BATTERY TYPE
OUTPUT BREAKERS
DH - Illuminator Series “CIII-H”
S-Standard (VRLA)
Example: C XX 01
VOLTAGE (INPUT/OUTPUT)1
KVA/KW2
RUNTIME3
1 - 120/208
2 - 277/480
1 - 4.8
2-6
3-8
4 - 10
5 - 12.5
6 - 16.7
7 - 24
8 - 33
9 - 40
10 - 50
(90 minutes)
2YW- Factory Start-Up
Extended 2-Year
Electronic
Warranty
5YW- 5-Year Electronics
Warranty (Includes
Start-up)
5YP- 5-Year Maintenance
Plan, Start-Up
Included
POLE
(See chart on page 3
for dimensional details)
C - 3-Pole
OPTIONS
AMP RATING
A - Remote Summary Alarm Panel
C - Status Monitoring Dry Form C Contacts
F - Fast Charge
I - Inverter On Dry Form C Contact
S - Summary Dry Form C Contact
(Based on System
KVA SIZE)
1) Standard input voltage is 4-Wire Wye. 3-Wire Delta Input requires
external isolation transformer.
2) KVA = KW
3) Standard battery run time is 90 minutes.
4) Standard 1 year full warranty
UPS ELECRONICS MODULE
WARRANTY4
01
BATTERIES
BATTERY MODULE
TOTAL SYSTEM
DIMENSIONS
Power Rating (kW)
Efficiency (@ full load)
Voltage (VDC)
Audible Noise (dBA @ 1m)
Base
Model
Number
DH-1-S
DH-2-S
DH-3-S
5
Weight
lbs/kg
Total Battery Weight
lbs/kg
Run Time (mins)
Number of
Battery Cabinets
Weight
lbs/kg
4.8
6.0
8.0
98 45 326
98 45 408
98 45 544
535/243
535/243
535/243
888/403
1110/504
1480/672
12
15
20
DH-4-S 10.0 10.0
DH-5-S 12.5 12.5
DH-6-S 16.7 16.7
98 45 680
98 45 850
98 45 1136
639/290
639/290
639/290
1776/806
2220/1007
2960/1343
24
30
40
144 39 90
180 39 90
240 39 90
144 81 90
180 81 90
240 81 90
1250/567
1250/567
1450/658
1460/663
4440/2014
6080/2758
7400/3357
9120/4137
60
80
100
60
240
240
240
240
DH-7-S
DH-8-S
DH-9-S
DH-10-S
4.8
6.0
8.0
Current (Amperes)
Number of
Batteries
24.0
33.0
40.0
50.0
24.0
33.0
40.0
50.0
98
98
98
98
45
45
45
45
1632
2244
2720
3400
117
160
194
243
Width
in/cm
Height
in/cm
Depth
in/cm
Total
System
Weight
lbs./kg
210/96
210/96
232/106
1
1
1
66/168 47/120
66/168 47/120
66/168 47/120
25/64
25/64
25/64
1633/741
1855/842
2247/1020
420/191
420/191
464/211
2
2
2
96/244 47/120
96/244 47/120
96/244 47/120
25/64
25/64
25/64
2835/1286
3279/1488
4063/1843
99/252
147/374
147/374
147/374
35/89 6390/2899
35/89 8630/3915
35/89 10150/4604
35/89 11980/5435
90 700/318 1
90 1300/590 2
90 1300/590 2
90 1400/635 2
72/183
72/183
72/183
72/183
E-MAIL/MODEM
User can enable/disable and program alarms that will
trigger messages to e-mail destinations. User can set up
specific alarm events that will alert service or maintenance
personnel. The system will transmit monthly and yearly
tests per NFPA requirements. Bi-directional communication
eases system diagnostics and data retrieval through the
RS-232 serial communication port.
SUMMARY FORM C CONTACT
Form “C” contacts rated at 5 amps maximum at
250VAC/30VDC. Dry contact will change state when any
system alarm activates. Contacts change state with the
following alarms: High/low battery charger fault, near low
battery, low battery, load reduction fault, output overload,
high/low AC input volts, high ambient temperature, inverter
fault, test failure, and optional circuit breaker trip alarm.
TIME DELAY
Delays retransfer of inverter to continue supplying
emergency power to the normally off output for 15 minutes
after the return of utility power.
INVERTER ON FORM C CONTACT
Form “C” dry contact that will change state when the
inverter transfers to battery operation.
OUTPUT CIRCUIT BREAKER
Maximum output breakers available: 12 unsupervised (1pole) or 8 supervised (1-pole) for 1.5 - 5 kVA, and 24
unsupervised (1-pole) or 15 supervised (1-pole) for 6 - 16.7
kVA. Additional output or breakers available on 1.5 - 5kVA
systems (additional 30 pole positions for 42 positions total;
enclosure height increases to 62”).
Power Rating (kVA)
Heat Loss (BTU)
OPTIONS AVAILABLE
QTY.
OUTPUT TRIP ALARM
An audible and visual alarm activates when an output
distribution circuit breaker is open or has tripped.
MAINTENANCE BYPASS
This device is internally mounted in the system and permits
maintenance personnel to easily bypass the inverter and
connect directly to the AC utility power. The “make before
break” switch isolates the electronics or inverter system to
allow performance of routine maintenance or servicing.
REMOTE SUMMARY ALARM PANEL
A wall mountable box containing an audible alarm and light
that will activate upon any system alarm with silence switch.
STATUS MONITORING CONTACTS
Multiple Form “C” dry contacts capable of monitoring
system and option statuses (Inverter On, Inverter Off, AC
Present, High Temperature, Summary Alarm, System
Bypass*, and OTA*)
*Requires purchase of Maintenance Bypass and/or
Output Trip Alarm options.
FAST CHARGE
This is a battery charger upgrade which decreases the time
to recharge a fully discharged battery bank to a full charge.
The recharge time is decreased from the standard 24-hour
period to a 12-hour period.
NORMALLY OFF OUTPUT (Standard on Series IE)
This output circuit is dedicated for emergency only lighting
fixtures. Emergency only loads operate during power
outages and when the system is on battery back up. This
option leaves selective load circuits off during normal utility
power conditions.
2
ILLUMINATOR CIII-H THREE PHASE
ORDERING GUIDE
Example Model Number
1-EH-4-S-BA2007-F-T-S-M-R-2YW
SYSTEM TYPE
BATTERY TYPE
OUTPUT BREAKERS5
EH - Illuminator Series “E-H”
IEH - Illuminator Series “IE-H”
S-Standard (VRLA)
Example: B A 20 07
VOLTAGE (INPUT/OUTPUT)1
KVA/KW2
RUNTIME3
1 - 120-120
2 - 120-120/277
3 - 208-120
4 - 240-120/240
5 - 277-120
6 - 277-277
7 - 277-277/120
8 - 208-120/240
A - 208-120/208
Z - Other Voltages
1 - 1.5
2 - 2.25
3 - 3.0
4 - 3.75
5 - 5.0
6 - 6.0
7 - 8.0
8 - 10.0
9 - 12.5
10 - 16.7
(90 minutes)
WARRANTY7
2YW - Factory Start-Up
Extended 2-Year
Electronics Warranty
5YP - 5-Year
Preventative
Maintenance Plan,
Start-Up Included
5YW - 5-Year Electronics
Warranty
(includes start-up)
SMP8 - Service Monitoring
Plan
OUTPUT
OPTIONS
B-Normally On
N-Normally Off4
1) Only single phase voltages available.
2) KVA = KW
3) Standard battery run time is 90 minutes.
4) Normally off loads on Series E-H cannot exceed 20% of total KVA rating with
any combination of H.I.D. Loads. Contact factory for clarification.
5) Maximum output breakers available: 12 unsupervised (1-pole), or
8 supervised (1-pole) for 1.5 - 5 kVA, (additional Circuit Breaker Options
available, consult factory), and 24 unsupervised (1-pole), or 15 supervised
(1-pole) for 6 - 16.7 kVA. Breakers provided are 20 Amps unless specified
otherwise. A 2-pole breaker occupies 2 positions.
6) Maintenance bypass switch is a “make before break”.
7) Standard one year full warranty.
8) Requires Factory Start-up and E-mail/Modem options. This program will
provide monitoring of the lighting inverter system by our factory service
department. All monthly and yearly system tests will be reviewed by our
factory service department for early warning signs of any system malfunction.
Any system alarms and monthly/yearly test results will automatically be Emailed to our service department where corrective action can be taken and
while under warranty, if necessary, a factory authorized service technician will
be scheduled to complete any necessary repairs. This monitoring program will
require a dedicated analog telephone line.
9) 15 minute retransfer time delay of normally off circuit after return of utility.
A - Remote Summary Alarm
Panel
E - E-Mail Modem
F - Fast Charge
I - Inverter On Dry Contacts
M - Maintenance Bypass6
N - Normally Off Output (Std. on
IE)4
R - Remote Meter Panel
S - Summary Fault Form C
Contacts
T - Output Trip5 (Supervised)
Alarm
V - Time Delay 15 min. (for
normally off circuits only)9
VOLTAGE
A-120
B-208
C-240
D-277
Z-Other
AMP RATING
10, 15, 20, 25,
30, 40, 50, 60
QUANTITY
01 - 245
(List all circuit breaker
requirements separately,
ex: BA2007 - NA1001 )
ELECTRONICS MODULE
(See chart on page 5 for dimensional details)
STANDARD FEATURES Illuminator CIII-H
BATTERIES
(90 minutes @ full load)
Power Rating (kVA)
Power Rating (kW)
•
•
Number of Batteries
Efficiency (@ full load)
Voltage (VDC)
Audible Noise (dBA @ 1m)
Current (Amperes)
Heat Loss (BTU)/HR
Cabinet Dimensions
1.5
2.25
3.0
3.75
5.0
6.0
8.0
10.0
12.5
16.7
3
1.5
2.25
3.0
3.75
5.0
6.0
8.0
10.0
12.5
16.7
98
98
98
98
98
98
98
98
98
98
45 102
45 153
45 204
45 255
45 340
45 408
45 544
45 680
45 850
45 1135
Width
in/cm
Height
in/cm
Depth
in/cm
Weight
lbs/kg
90 Minute
Batteries
lbs/kg
30/77
30/77
30/77
30/77
30/77
53/122
53/122
53/122
53/122
53/122
47/119
47/119
47/119
47/119
47/119
76/193
76/193
76/193
76/193
76/193
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
215/98
230/105
235/107
240/109
280/128
605/272
640/288
785/353
805/362
885/398
296/135
444/200
592/266
740/330
888/400
1110/500
1480/666
1776/800
2220/999
2960/1332
Total
System
Weight
lbs/kg
4
6
8
10
12
15
20
24
30
40
48
72
96
120
144
180
240
144
180
240
39
38
38
37
41
40
39
82
82
80
511/230
674/306
827/372
980/441
1168/525
1715/772
2120/954
2561/1153
3025/1361
3845/1730
•
•
•
•
•
•
•
•
UL 924 Listed
System Compatible with all lighting loads
including HID and LED
True Sine Wave Output
98% Efficient
PWM/IGBT Technology
Micro-processor Control
User programmable with Password Protection
Automatic Self-test, Event and Alarm Logs
OSHPD Special Seismic Certification,
No. OSP-0258-10
High Crest Factor
•
•
•
•
•
•
•
•
•
•
Input Circuit Breaker
Main 3-pole output circuit breaker
Modular Design
Low audible noise 45Dba
Internal Battery Circuit Breaker and/or Fuse
Meets NFPA-101 for self-testing and selfdiagnostics
65kAIC Rating
Load Reduction Fault
Air Filters not required
Internal Maintenance Bypass Switch
4
ILLUMINATOR CIII-H THREE PHASE
ORDERING GUIDE
Example Model Number
1-EH-4-S-BA2007-F-T-S-M-R-2YW
SYSTEM TYPE
BATTERY TYPE
OUTPUT BREAKERS5
EH - Illuminator Series “E-H”
IEH - Illuminator Series “IE-H”
S-Standard (VRLA)
Example: B A 20 07
VOLTAGE (INPUT/OUTPUT)1
KVA/KW2
RUNTIME3
1 - 120-120
2 - 120-120/277
3 - 208-120
4 - 240-120/240
5 - 277-120
6 - 277-277
7 - 277-277/120
8 - 208-120/240
A - 208-120/208
Z - Other Voltages
1 - 1.5
2 - 2.25
3 - 3.0
4 - 3.75
5 - 5.0
6 - 6.0
7 - 8.0
8 - 10.0
9 - 12.5
10 - 16.7
(90 minutes)
WARRANTY7
2YW - Factory Start-Up
Extended 2-Year
Electronics Warranty
5YP - 5-Year
Preventative
Maintenance Plan,
Start-Up Included
5YW - 5-Year Electronics
Warranty
(includes start-up)
SMP8 - Service Monitoring
Plan
OUTPUT
OPTIONS
B-Normally On
N-Normally Off4
1) Only single phase voltages available.
2) KVA = KW
3) Standard battery run time is 90 minutes.
4) Normally off loads on Series E-H cannot exceed 20% of total KVA rating with
any combination of H.I.D. Loads. Contact factory for clarification.
5) Maximum output breakers available: 12 unsupervised (1-pole), or
8 supervised (1-pole) for 1.5 - 5 kVA, (additional Circuit Breaker Options
available, consult factory), and 24 unsupervised (1-pole), or 15 supervised
(1-pole) for 6 - 16.7 kVA. Breakers provided are 20 Amps unless specified
otherwise. A 2-pole breaker occupies 2 positions.
6) Maintenance bypass switch is a “make before break”.
7) Standard one year full warranty.
8) Requires Factory Start-up and E-mail/Modem options. This program will
provide monitoring of the lighting inverter system by our factory service
department. All monthly and yearly system tests will be reviewed by our
factory service department for early warning signs of any system malfunction.
Any system alarms and monthly/yearly test results will automatically be Emailed to our service department where corrective action can be taken and
while under warranty, if necessary, a factory authorized service technician will
be scheduled to complete any necessary repairs. This monitoring program will
require a dedicated analog telephone line.
9) 15 minute retransfer time delay of normally off circuit after return of utility.
A - Remote Summary Alarm
Panel
E - E-Mail Modem
F - Fast Charge
I - Inverter On Dry Contacts
M - Maintenance Bypass6
N - Normally Off Output (Std. on
IE)4
R - Remote Meter Panel
S - Summary Fault Form C
Contacts
T - Output Trip5 (Supervised)
Alarm
V - Time Delay 15 min. (for
normally off circuits only)9
VOLTAGE
A-120
B-208
C-240
D-277
Z-Other
AMP RATING
10, 15, 20, 25,
30, 40, 50, 60
QUANTITY
01 - 245
(List all circuit breaker
requirements separately,
ex: BA2007 - NA1001 )
ELECTRONICS MODULE
(See chart on page 5 for dimensional details)
STANDARD FEATURES Illuminator CIII-H
BATTERIES
(90 minutes @ full load)
Power Rating (kVA)
Power Rating (kW)
•
•
Number of Batteries
Efficiency (@ full load)
Voltage (VDC)
Audible Noise (dBA @ 1m)
Current (Amperes)
Heat Loss (BTU)/HR
Cabinet Dimensions
1.5
2.25
3.0
3.75
5.0
6.0
8.0
10.0
12.5
16.7
3
1.5
2.25
3.0
3.75
5.0
6.0
8.0
10.0
12.5
16.7
98
98
98
98
98
98
98
98
98
98
45 102
45 153
45 204
45 255
45 340
45 408
45 544
45 680
45 850
45 1135
Width
in/cm
Height
in/cm
Depth
in/cm
Weight
lbs/kg
90 Minute
Batteries
lbs/kg
30/77
30/77
30/77
30/77
30/77
53/122
53/122
53/122
53/122
53/122
47/119
47/119
47/119
47/119
47/119
76/193
76/193
76/193
76/193
76/193
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
25/64
215/98
230/105
235/107
240/109
280/128
605/272
640/288
785/353
805/362
885/398
296/135
444/200
592/266
740/330
888/400
1110/500
1480/666
1776/800
2220/999
2960/1332
Total
System
Weight
lbs/kg
4
6
8
10
12
15
20
24
30
40
48
72
96
120
144
180
240
144
180
240
39
38
38
37
41
40
39
82
82
80
511/230
674/306
827/372
980/441
1168/525
1715/772
2120/954
2561/1153
3025/1361
3845/1730
•
•
•
•
•
•
•
•
UL 924 Listed
System Compatible with all lighting loads
including HID and LED
True Sine Wave Output
98% Efficient
PWM/IGBT Technology
Micro-processor Control
User programmable with Password Protection
Automatic Self-test, Event and Alarm Logs
OSHPD Special Seismic Certification,
No. OSP-0258-10
High Crest Factor
•
•
•
•
•
•
•
•
•
•
Input Circuit Breaker
Main 3-pole output circuit breaker
Modular Design
Low audible noise 45Dba
Internal Battery Circuit Breaker and/or Fuse
Meets NFPA-101 for self-testing and selfdiagnostics
65kAIC Rating
Load Reduction Fault
Air Filters not required
Internal Maintenance Bypass Switch
4
ILLUMINATOR E/IE-H SINGLE PHASE
ORDERING GUIDE
Example Model Number
1-DH-4-S-C3001-C-I-S-2YW
SYSTEM TYPE
BATTERY TYPE
OUTPUT BREAKERS
DH - Illuminator Series “CIII-H”
S-Standard (VRLA)
Example: C XX 01
VOLTAGE (INPUT/OUTPUT)1
KVA/KW2
RUNTIME3
1 - 120/208
2 - 277/480
1 - 4.8
2-6
3-8
4 - 10
5 - 12.5
6 - 16.7
7 - 24
8 - 33
9 - 40
10 - 50
(90 minutes)
2YW- Factory Start-Up
Extended 2-Year
Electronic
Warranty
5YW- 5-Year Electronics
Warranty (Includes
Start-up)
5YP- 5-Year Maintenance
Plan, Start-Up
Included
POLE
(See chart on page 3
for dimensional details)
C - 3-Pole
OPTIONS
AMP RATING
A - Remote Summary Alarm Panel
C - Status Monitoring Dry Form C Contacts
F - Fast Charge
I - Inverter On Dry Form C Contact
S - Summary Dry Form C Contact
(Based on System
KVA SIZE)
1) Standard input voltage is 4-Wire Wye. 3-Wire Delta Input requires
external isolation transformer.
2) KVA = KW
3) Standard battery run time is 90 minutes.
4) Standard 1 year full warranty
UPS ELECRONICS MODULE
WARRANTY4
01
BATTERIES
BATTERY MODULE
TOTAL SYSTEM
DIMENSIONS
Power Rating (kW)
Efficiency (@ full load)
Voltage (VDC)
Audible Noise (dBA @ 1m)
Base
Model
Number
DH-1-S
DH-2-S
DH-3-S
5
Weight
lbs/kg
Total Battery Weight
lbs/kg
Run Time (mins)
Number of
Battery Cabinets
Weight
lbs/kg
4.8
6.0
8.0
98 45 326
98 45 408
98 45 544
535/243
535/243
535/243
888/403
1110/504
1480/672
12
15
20
DH-4-S 10.0 10.0
DH-5-S 12.5 12.5
DH-6-S 16.7 16.7
98 45 680
98 45 850
98 45 1136
639/290
639/290
639/290
1776/806
2220/1007
2960/1343
24
30
40
144 39 90
180 39 90
240 39 90
144 81 90
180 81 90
240 81 90
1250/567
1250/567
1450/658
1460/663
4440/2014
6080/2758
7400/3357
9120/4137
60
80
100
60
240
240
240
240
DH-7-S
DH-8-S
DH-9-S
DH-10-S
4.8
6.0
8.0
Current (Amperes)
Number of
Batteries
24.0
33.0
40.0
50.0
24.0
33.0
40.0
50.0
98
98
98
98
45
45
45
45
1632
2244
2720
3400
117
160
194
243
Width
in/cm
Height
in/cm
Depth
in/cm
Total
System
Weight
lbs./kg
210/96
210/96
232/106
1
1
1
66/168 47/120
66/168 47/120
66/168 47/120
25/64
25/64
25/64
1633/741
1855/842
2247/1020
420/191
420/191
464/211
2
2
2
96/244 47/120
96/244 47/120
96/244 47/120
25/64
25/64
25/64
2835/1286
3279/1488
4063/1843
99/252
147/374
147/374
147/374
35/89 6390/2899
35/89 8630/3915
35/89 10150/4604
35/89 11980/5435
90 700/318 1
90 1300/590 2
90 1300/590 2
90 1400/635 2
72/183
72/183
72/183
72/183
E-MAIL/MODEM
User can enable/disable and program alarms that will
trigger messages to e-mail destinations. User can set up
specific alarm events that will alert service or maintenance
personnel. The system will transmit monthly and yearly
tests per NFPA requirements. Bi-directional communication
eases system diagnostics and data retrieval through the
RS-232 serial communication port.
SUMMARY FORM C CONTACT
Form “C” contacts rated at 5 amps maximum at
250VAC/30VDC. Dry contact will change state when any
system alarm activates. Contacts change state with the
following alarms: High/low battery charger fault, near low
battery, low battery, load reduction fault, output overload,
high/low AC input volts, high ambient temperature, inverter
fault, test failure, and optional circuit breaker trip alarm.
TIME DELAY
Delays retransfer of inverter to continue supplying
emergency power to the normally off output for 15 minutes
after the return of utility power.
INVERTER ON FORM C CONTACT
Form “C” dry contact that will change state when the
inverter transfers to battery operation.
OUTPUT CIRCUIT BREAKER
Maximum output breakers available: 12 unsupervised (1pole) or 8 supervised (1-pole) for 1.5 - 5 kVA, and 24
unsupervised (1-pole) or 15 supervised (1-pole) for 6 - 16.7
kVA. Additional output or breakers available on 1.5 - 5kVA
systems (additional 30 pole positions for 42 positions total;
enclosure height increases to 62”).
Power Rating (kVA)
Heat Loss (BTU)
OPTIONS AVAILABLE
QTY.
OUTPUT TRIP ALARM
An audible and visual alarm activates when an output
distribution circuit breaker is open or has tripped.
MAINTENANCE BYPASS
This device is internally mounted in the system and permits
maintenance personnel to easily bypass the inverter and
connect directly to the AC utility power. The “make before
break” switch isolates the electronics or inverter system to
allow performance of routine maintenance or servicing.
REMOTE SUMMARY ALARM PANEL
A wall mountable box containing an audible alarm and light
that will activate upon any system alarm with silence switch.
STATUS MONITORING CONTACTS
Multiple Form “C” dry contacts capable of monitoring
system and option statuses (Inverter On, Inverter Off, AC
Present, High Temperature, Summary Alarm, System
Bypass*, and OTA*)
*Requires purchase of Maintenance Bypass and/or
Output Trip Alarm options.
FAST CHARGE
This is a battery charger upgrade which decreases the time
to recharge a fully discharged battery bank to a full charge.
The recharge time is decreased from the standard 24-hour
period to a 12-hour period.
NORMALLY OFF OUTPUT (Standard on Series IE)
This output circuit is dedicated for emergency only lighting
fixtures. Emergency only loads operate during power
outages and when the system is on battery back up. This
option leaves selective load circuits off during normal utility
power conditions.
2
SYSTEM SPECIFICATIONS
THE ILLUMINATOR -H SEISMIC SERIES
The Illuminator Series E/IE-H and CIII-H are the latest innovation in Emergency Lighting Inverter
technology. The Illuminator -H series is Myers’ shaker table tested and approved expansion to the
industry leading Central Emergency Lighting inverters.
INPUT
Voltage
Input Power Walk-in
Input Frequency
Synchronizing Slew Rate
Protection
AIC Rating
Power Factor
These systems meet the requirements of CBC 2010 and IBC 2009 and have been shaker table
tested in accordance with ICC-ES-AC-156 procedures to an SDS level of 2.5g. In addition they
have received OSHPD (California Office of Statewide Health Planning and Development) Special
Seismic Certification. This is the most rigid seismic standards currently being specified.
SEISMIC SYSTEMS E-H, IE-H, CIII-H
OUTPUT
Voltage
Dynamic Voltage
Harmonic Distortion
Overload
Output Frequency
Load Power Factor
Inverter Overload
Illuminator E-H
The Illuminator Series E-H single phase uninterruptible system features sizes from 1.5-16.7
kVA/kW. This fast transfer system is designed to support all types of fixtures in emergency
applications including HID, LED, and fluorescent. In addition this system can support mixed loads
of all different types. The line interactive design eliminates excessive transfers to battery power.
The Illuminator Series E-H transfers to inverter mode (battery power) within 2ms of loss of utility
power in order to maintain the arc of an HID light.
Protection
Crest Factor
Illuminator CIII-H
Type
Charger
Protection
Disconnect
Optional Runtimes
Altitude
Operating Temperature
Storage Temperature
Relative Humidity
•
1
< 10,000 feet (above sea level) without derating.
Inverter: 0° to 40°C (32° to 104°F); Battery: 20° to 30°C (68° to 86°F) per UL 924.
-20° to 70°C (-4° to 158°F) (electronics only).
< 95% (non-condensing).
GENERAL
Efficiency
Design
Output Circuits
Generator Input
Control Panel
STANDARD FEATURES Illuminator E/IE-H
UL 924 Listed
98% Efficient
PWM/IGBT Technology
Micro-processor Control
User Programmable Front Meter Panel
Automatic Selt-test, Event and Alarm Logs
OSHPD Special Seismic Certification
No. OSP-0305-10
High Crest Factor
Valve-regulated, sealed lead-calcium.
Microprocessor controlled and temperature compensating; recharge per UL 924 spec.
Automatic low-battery disconnect; automatic restart upon utility return.
Series E-H / IE-H and Series CIII-H, 4.8-16.7k fuse(s);
Series CIII-H, 24-50k circuit breaker / fuse(s).
Extended run times available. Consult factory for additional information.
ENVIRONMENTAL
The Illuminator Series CIII-H three phase uninterruptible system features sizes from 4.8 to 50
kVA/kW. As with Myers’ other uninterruptible systems the CIII-H series is designed to support all
lamp sources including HID and LED. Its large capacity is perfect for larger industrial and
commercial applications. It can also help to provide load balancing within a facility with its wide
range of sizes.
•
•
•
•
•
•
•
120 or 277VAC, 1-phase, 2-wire + G (Series E-H / IE-H).
120/208 or 277/480VAC, 3-phase, 4-wire + G (Wye or Delta) (Series CIII-H).
Contact factory for all other voltages.
+/- 2% for +/-25% load step change, recovery within 3 cycles.
< 3% THD for linear load.
Fuse protected.
60Hz +/- 0.05Hz during emergency mode.
0.5 lag to 0.5 lead.
115% for 10 minutes; 125% for 5 minutes; 280% for 16 line cycles (Series E-H / IE-H);
280% for 12 line cycles (Series CIII-H).
Series E-H / IE-H - main or distribution circuit breaker(s).
Series CIII-H - optional main circuit breaker.
2.8
BATTERY
Illuminator IE-H
The Illuminator Series IE-H single phase standard transfer system features sizes from 1.5-16.7
kVA/kW; it is designed to support all lighting loads except HID. This includes LED, fluorescent,
incandescent and quartz fixtures. This system comes standard with normally on and normally off
(emergency only) outputs.
120 or 277VAC (+10% / -20%), 1-phase, 2-wire + G (Series E-H).
120 or 277VAC (+10% / -15%), 1-phase, 2-wire + G (Series IE-H).
120/208 or 277/480VAC (+10% / -15%), 3-phase, 4-wire + G (Wye) (Series CIII-H).
Contact factory for all other voltages.
Limiting inrush current to less than 125% of full rated load; 10 times for 1 line cycle.
60Hz, +/- 3%.
1Hz per second nominal.
Input Circuit Breaker.
65k RMS symmetrical ampere short-circuit rating.
0.5 lag/lead.
•
•
•
•
•
•
•
•
Input Main Circuit Breaker
True Output Sine Wave
Meets NFPA-101 for self-testing and selfdiagnostics
Low Audible Noise 45Dba
Modular Design
Load Reduction Fault
Air Filters not required
65 kAIC rating
Metering
Alarms
Communications
Manual Maintenance Bypass
Alarm Contacts
Warranty
Factory Start-up
5-Year Maintenance Plan
98%.
Standby UPS; PWM inverter type utilizing IGBT technology with 2ms transfer time on
Series CIII-H and Series E-H and 50ms on Series IE-H.
Series E-H - Normally On Circuit standard; Normally Off Circuit optional.
Series IE-H - Normally On and Normally Off Circuits standard.
Series CIII-H - Normally On Circuit standard; Normally Off Circuit optional.
Compatible with generators.
Microprocessor controlled with user friendly display, touchpad controls/functions and
system status indications.
Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA,
Temperature, Inverter Wattage.
High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction
Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature,
Inverter Fault, Output Fault, Test Failure, and Optional Circuit Breaker Trip.
RS-232 port (DB9 standard). See ordering guide for additional available options.
Standard internal on Series CIII-H; optional internal on Series E-H / IE-H. Make before break.
Optional summary alarm and / or status monitoring form "C" contacts.
1 year standard warranty includes all parts, labor & travel expenses within the
48 contiguous states. 10 years prorated warranty on batteries. Extended warranties, preventative maintenance and
customized service plans are available.
Purchase factory start-up & receive 1 additional year of electronics warranty.
Purchase 5-year preventative maintenance plan & receive free factory start-up.
PHYSICAL
Cabinet
Cooling
Cable Entry
Access
Freestanding NEMA Type 1; reinforced and approved for seismic withstand.
Forced air during emergency. Convection cooled during normal operation. No filters required.
Series E-H / IE-H: top or sides on 1.5 - 5kVA; sides only on 6 - 16.7kVA.
Series CIII-H: top, bottom or sides.
Front ONLY is required.
6
SEISMIC CATALOG
ALSO AVAILABLE FROM MYERS POWER PRODUCTS:
ILLUMINATOR E-H/IE-H & ILLUMINATOR CIII-H
Illuminator Series E/IE
Single Phase
1.5kVA/kW to 16.7kVA/kW
Illuminator Series CIII
Three Phase
4.8kVA/kW to 50kVA/kW
UL-924 Listed
Emergency Lighting
and Power Equipment
1.5kVA/kW to 16.7kVA/kW Single Phase
4.8kVA/kW to 50kVA/kW Three Phase
65kAIC Rated
Shaker Table Tested to SDS Level 2.5
Illuminator Series EM
Single Phase
1kVA/kW to 2.8kVA/kW
Listed to CBC2010, IBC2009, AC156
44 S. Commerce Way
Bethlehem, PA 18017
Phone: (610) 868-3500
Fax: (610) 868-8686
www.myerspowerproducts.com
Illuminator Series CR/DR
Single and Three Phase
Outdoor System 3kVA/kW to 8kVA/kW
ELP-0008-DS-1212
98% Efficient