StarMark - Star Building Systems
StarMark Wall System Description StarMark is a functional 36" wide wall panel that provides aesthetics and cost efficiency. An architecturally sculptured shadow panel is achieved with 1" deep ribs to help conceal fasteners. Major corrugations on 12" center not only provide panel strength and integrity, they enhance the panel’s aesthetically pleasing sculptured look as well. Gauge 26 gauge (standard) 24 gauge Length Maximum length of 32'-0" Dimensions 36" wide by 1" high Finish Galvalume Plus® Signature® 200 Colors Signature® 300 Colors Fasteners Semi-concealed, self drilling fasteners, long life coated to match wall color Usage Wall panel, liner panel and façade panel 5. Signature® 200 Colors 6. Signature® 300 Colors option Roof and Wall Systems 3. Continuous eave to sill to 32' length 4. Fire Rating 1. Attractive architectural application 2. Conceals panel side laps for aesthetically pleasing appearance 3. Eliminates end laps and improves appearance 4. The panel is classified by UL® for 1 & 2 hour fire resistance 5. 25-year finish warranty 6. 25-year premium paint finish warranty with ultimate resistance to chalking and color changes Standing Seam Roof System 1. Semi-concealed fastener panel 2. Unique side lap feature Advantages Insulated Panel Systems Attributes StarMark Wall System StarMark - Section Properties Properties Notes: NEGATIVE BENDING Sx (IN.3/FT.) Ix (IN.4/FT.) Sx (IN.3/FT.) Fb (KSI) 0.752 0.03748 0.05073 0.03552 0.05763 30 0.927 0.04551 0.06160 0.04313 0.06998 30 Ap (IN2/FT.) 26 24 G' (#/IN.) 1. Section properties have been calculated in accordance with the 1986 AISI ColdFormed Specification with 1989 addendum. POSITIVE BENDING Ix (IN.4/FT.) PANEL GAUGE 2. Steel thickness was used in determining section properties. Coated thickness includes galvanized or zinc-aluminum coating. Allowable Load (PSF) For Nominal Purlin Spacing Allowable Uniform Loads Notes: 26 Gauge SPAN TYPE SIMPLE 2-SPAN 3-SPAN LOAD CONDITION 1. Top values are based on stress. ¹/3 for wind load is included. PURLIN SPACE 5' 6' 7' PRESSURE 54.00 52.42 37.50 30.34 27.55 19.10 SUCTION 61.35 49.68 42.60 28.75 31.30 18.10 PRESSURE 61.35 123.09 42.60 71.23 31.30 44.86 SUCTION 54.00 123.09 37.50 71.23 27.55 44.86 PRESSURE 76.69 96.33 53.25 55.75 39.13 35.10 SUCTION 67.50 96.33 46.88 55.75 34.44 35.10 2. Bottom values are based on deflection of L/120 for 10 year wind (L/90 for 50 year wind). 3. Standard fastener pullover allowable is 222 lbs. including 1.3 increase for wind (#12 fastener without washer). 24 Gauge SPAN TYPE SIMPLE 2-SPAN 3-SPAN LOAD CONDITION PURLIN SPACE 5' 6' 7' PRESSURE 65.58 63.65 45.54 36.83 33.46 23.20 SUCTION 74.50 60.32 51.73 34.91 38.01 21.98 PRESSURE 74.50 149.46 51.73 86.49 38.01 54.47 SUCTION 65.58 149.46 45.54 86.49 33.46 54.47 PRESSURE 93.12 116.97 64.67 67.69 47.51 42.63 SUCTION 81.97 116.97 56.92 67.69 41.82 42.63 Roof and Wall Systems Standing Seam Roof Systems The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This specification contains the design criteria for cold-formed steel components. Along with the specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If fur ther information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. Star Building Systems an NCI Company EFFECTIVE JULY 22, 2010 SUBJECT TO CHANGE WITHOUT NOTICE 8600 South I-35, Oklahoma City, OK 73149 Galvalume Plus® is a registered trademark of BIEC International, Inc. Signature® is a registered trademark of the NCI Group. [email protected] Insulated Panel Systems 36" 1" 2¼" www.StarBuildings.com