NonStop® - Bowsmith

Transcription

NonStop® - Bowsmith
Product Description
NonStop®
Bowsmith NonStop Series Emitters incorporate
a series of flexible silicone orifices. The silicone is
highly resistant to chlorine and most commonly
used fertilizers. Each orifice retains its shape and
performance for years.
Bowsmith’s famed NonStop emitter family, is
known worldwide for unmatched performance
under the most challenging conditions. The
“NonStop” design features the exclusive Continuous
Flushing Action, which continually flushes the
emitter of slime and small particles while the
emitter is in operation. This means fewer clogs and
lower maintenance requirements.
Drip Emitters
Product Description
The Bowsmith NonStop emitter design, patented in 1974, is based on a simple unique principle found in no other
emitter. This Pressure Cascade Principle permits the emitter to tolerate large amounts of suspended solids in irrigation
water, without clogging and without the need for fine-mesh
screens.
How filter
it works
1 Under normal conditions, there is a slight pres-
sure differential across each orifice in the silicone
diaphragm.
How it works
path is a series
of orifices
in the
1 The flow
2 As a particle
encounters
the orifice,
there
is asilicone diaphragm.
0
PSI
18
PSI
20
PSI
20
PSI
Orifice Open Low pressure
across diaphragm
(Approximately 2 psi)
momentary obstruction, causing the differential
pressure across the orifice to increase greatly.
This pushes
the particle
through
thepressure
expanding
operation,
the total
difference between
2 Ininletnormal
orifice.
and outlet is divided equally across each of the orifices
18
PSI
in the flow path.
- For example: 20 psi inlet pressure, and 10 orifices in the
flow path, the pressure drop across each orifice is 2 psi.
20
PSI
Momentary Blockage High difference
pressure
(Up to line pressure)
3 The particle
is then flushed through the orifice,
If an obstruction should occur in any of the orifices, the flow
which
to its normal size. Normal
3instantly returns
that are
orifice
will be momentarily
restricted. As a result,
pressure through
conditions
restored.
The particle
pressurethe
drop
across thatorifices
orifice will
increase, causing the
continuesthe
through
remaining
in the
orifice
enlarge
until
the obstruction
diaphragm
andtoout
of the
NonStop
emitter.has passed.
Obstruction
pushed through Low difference
pressure restored
NonStop Drip Emitters
Nominal Performance
Flow, GPH (LPH)
For over 40 years, millions of Bowsmith NonStop emitters have demonstrated that the unique NonStop Continuous
4.0
Self-Cleaning Action ( Pressure
(15.1) Cascade Principle) really works, even under conditions that would quickly clog ordinary
emitters. With only 30-mesh filtration (recommended minimum), Bowsmith NonStop emitters have operated successfully
with water containing heavy
3.0concentrations of sand, silt, iron bacteria “slime”, calcium carbonates, even algae and moss.
(11.4)
2.0 GPH Models*
This means:
• Trees & Plants will
2.0be Irrigated
(7.6)Loss and Stress
• Reduction in Plant
1.0 GPH Models*
• Less Maintenance-Lower Labor Costs
1.0
• Lower Capital Investment
in Filtration Equipment.
(3.8)
GPH
Models*
Bowsmith emitters are available in single and multi outlet models, and with flow rates of 0.6 gph, 1.0 gph, 2.00.6
gph,
and
3.0 gph.
0
10
(0.69)
15
(1.03)
20
(1.38)
Pressure, PSI (bars)
Bowsmith, Inc.
DE01-0700
“SL” Series
• Manufacturer’s
variation, C v : ≤ 0.05
25
30
(1.72)
(2.07)
*Nominal Flow at 20 PSI
Toll-Free USA:
P.O. Box 428 • Exeter, CA 93221 USA
“ML” Series
Notes
• 30-mesh filtration and
15 PSI emitter operating pressure are the
recommended minimums for a NonStop
emitter system.
1-(800) BOWSMITH
1-(800) 269-7648
(559) 592-9485; Fax: (559) 592-2314
www.bowsmith.com
“SB” Series
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
rev.121515
NonStop
®
NONSTOP®
Drip Emitters
Drip Emitters
Product Description
Bowsmith’s famed NonStop Description
emitter family, is
known worldwide for unmatched
performance
Single
barb outlet,
“SB” challenging
Series
under the most
conditions.
0.250" andThe
0.175"
“NonStop” design features the exclusive
barbs onContinuous
opposite
Flushing Action, which continually
flushes
thebe
ends; either can
emitter of slime and small particles
while
the
used as inlet.
emitter is in operation. This means fewer clogs and
lower maintenance requirements.
Single outlet, 1/2"
“SL200” Series
FPT inlet. barbed
elbow outlet port.
“M200” Series
“ML200” Series
SB-30
6124
3.0 GPH (11.4 LPH) (Yellow Insert)
SL206
SL210
SL220
SL230
6034
6035
6036
6037
0.6 GPH
1.0 GPH
2.0 GPH
3.0 GPH
6 outlets open,
0.250" barb inlet.
Includes full set of
elbow/outlet caps
and line plugs.
M206
7063
How it works
6 outlets open, 1/2"
FPT inlet.
Includes full set of
elbow/outlet caps
and line plugs.
ML206
6 outlets open, 1/2"
Series “2000”
Flow Distributor FPT inlet.
Includes full set of
elbow/outlet caps
and line plugs.
“Gripper”
Series
Model
No. Stock
No. Specifications
Flow @ 20 PSI
Bowsmith
NonStop
Series Emitters–Nominal
incorporate
a series of flexible silicone orifices. The silicone is
SB-06
6120 to chlorine
(Green Insert)
0.6 GPH
LPH)
highly resistant
and( 2.3
most
commonly
used
fertilizers.
Each
orifice
retains
its
shape
andInsert)
SB-10
6121
(Blue
performance for years.1.0 GPH ( 3.8 LPH)
SB-20
6123
2.0 GPH ( 7.6 LPH) (Red Insert)
Single outlet, barb
inlet, gripper
sleeve.
Available factory installed on
Bowsmith tubing.
( 2.3 LPH)
( 3.8 LPH)
( 7.6 LPH)
( 11.5 LPH)
0.6 GPH ( 2.3 LPH)
(Green Port)
(Blue Port)
(Red Port)
(Yellow Port)
(Green Cap)
1 Under normal
there
a slight
presM210
7064 conditions,
1.0 GPH
( 3.8isLPH)
(Blue
Cap)
sure differential across each orifice in the silicone
diaphragm.
M220
7066
2.0 GPH ( 7.6 LPH) (Red Cap)
7068
0.6 GPH ( 2.3 LPH)
(Green Cap)
ML210
7069 encounters
1.0 GPH
3.8 LPH)
2 As a particle
the (orifice,
there(Blue
is a Cap)
momentary obstruction, causing the differential
ML220
GPHto( increase
7.6 LPH) greatly.
(Red Cap)
pressure7071
across the 2.0
orifice
This pushes the particle through the expanding
orifice. 6075
1.0 GPH ( 3.8 LPH) (Blue Cap)
FD-2010
@ 15-100 PSI
2.0 GPH ( 7.6 LPH) (Red Cap)
@ 15-100 PSI
3
The
particle
is
then
flushed
orifice, End)
NSG-06
6050
0.6
GPH through
( 2.3 LPH)the(Green
which instantly returns to its normal size. Normal
pressure6051
conditions1.0
areGPH
restored.
The particle
NSG-10
( 3.8 LPH)
(Blue End)
continues through the remaining orifices in the
NSG-20
6053and out2.0
(Red End)
GPHNonStop
( 7.6 LPH)
diaphragm
of the
emitter.
FD-2020
6080
NSG-30
6056
3.0 GPH ( 11.5 LPH) (Yellow End)
NonStop Drip Emitters
Nominal Performance
4.0
(15.1)
Notes
Flow, GPH (LPH)
NonStop Drip Emitters
• 30-mesh filtration and
15 PSI emitter operating pressure are the
Notes
recommended miniManufacturer’s varia-mums for a NonStop
Models*
Cv: ≤ 0.05
2.0 GPH Models* 1.0 GPHtion,
emitter system.
3.0
Nominal Performance
(11.4)
Flow, GPH (LPH)
4.0
(15.1)
3.0
(11.4)
2.0
(7.6)
2.0 GPH Models*
2.0
(7.6)
1.0
(3.8)
1.0 GPH Models*
0
10
(0.69)
1.0
(3.8)
0
10
(0.69)
15
(1.03)
20
(1.38)
Pressure, PSI (bars)
15
(1.03)
20
(1.38)
Bowsmith, Inc.
Pressure, PSI (bars)
P.O. Box 428 • Exeter, CA 93221 USA
DE01-0700
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
30-mesh filtration and
• Manufacturer’s
PSI emitter operat0.6 GPH15
Models*
variation, C v : ≤ 0.05
ing pressure are the
25
30minirecommended
(1.72)
(2.07)
mums for a NonStop
0.6 GPH Models* *Nominal Flow at 20 PSI
emitter system.
25
30
(1.72)
(2.07)
Toll-Free USA:
*Nominal Flow at 20 PSI
1-(800) BOWSMITH
1-(800) 269-7648
(559) 592-9485; Fax: (559) 592-2314
www.bowsmith.com
rev.121515
NonStop®
Drip Emitters
SB Series
• Single outlet.
• 0.175" O.D. or 0.250" O.D. inlet/outlet barb
connections on opposite ends. Either can be
used as outlet.
• Accessories: riser or feeder tubing for extending
the emitter away from the water supply. See the
illustration, below.
Stock No
6120
6121
6123
6124
Connection / Extension Options
Model No.
SB-06
(Green Insert)
SB-10
(Blue Insert)
SB-20
(Red Insert)
SB-30
(Yellow Insert)
Nominal Flow*
0.6 GPH
(2.3 LPH)
1.0 GPH
(3.8 LPH)
2.0 GPH
(7.6 LPH)
3.0 GPH
(11.4 LPH)
* Nominal Flow @ 20 PSI
Feeder Tube
0.220" O.D. x 0.160" I.D.
0.175" barb
“SB”Series Emitter
0.250" barb
Supply Tubing
0.175" barb
“SB”Series Emitter
0.250" barb
M200 Series
• Six open outlets. Each maintains its own flow
path .
• 0.250" barb inlet.
• Includes full set (6 each) of elbow/outlet caps,
and line plugs.
• One-piece elbow/outlet cap fixes position of
elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of
spreader tubing.
Stock No
Model No.
Nominal Flow*
7063
M206
0.6 GPH
(2.3 LPH)
1.0 GPH
(3.8 LPH)
2.0 GPH
(7.6 LPH)
7064
7066
each open outlet
(Green Cap)
M210
(Blue Cap)
M220
(Red Cap)
* Nominal Flow @ 20 PSI
• The elbow is easily reversed to cap off any
unused outlets.
• Line plugs can be placed in the end of the
spreader tubes to help keep bugs out, but still
allow passage of water.
NonStop Drip Emitters
Flow, GPH (LPH)
Nominal Performance
4.0
(15.1)
3.0
(11.4)
2.0
(7.6)
1.0
(3.8)
0
10
(0.69)
Notes
2.0 GPH Models*
1.0 GPH Models*
15
(1.03)
20
(1.38)
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
0.6 GPH Models*
25
30 Pressure, PSI
(1.72)
(2.07)
(bars)
• Manufacturer’s variation,
Cv:≤ 0.05
• 30-mesh filtration and 15
PSI emitter operating pressure are the recommended minimums for a NonStop emitter system.
rev.080615
NonStop®
Drip Emitters
Series 2000
Flow Distributor
• Two devices in one: drip emitter and pressure
regulator.
Stock No
Model No.
Nominal Flow*
6075
FD-2010
6080
FD-2020
1.0 GPH
(3.8 LPH)
2.0 GPH
(7.6 LPH)
• Pressure regulator operates on supply pressure
from 15 to 100 PSI.
• Pressure regulator valve uses durable, accurate
stainless steel spring.
• Six open outlets. Each maintains its own flow
path.
1
• /2" FPT inlet.
• Includes full set (6 each) of elbow/outlet caps,
and line plugs.
• One-piece elbow/outlet cap fixes position of
elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of
spreader tubing.
• The elbow is easily reversed to cap off any
unused outlets.
(Blue Cap)
(Red Cap)
TYPICAL INSTALLATION
FINISH
GRADE
FLOW
DISTRIBUTOR
BOWSMITH MODEL
SERIES 2000
(1/2" FPT FIELD INSTALLED
AFTER FLUSHING WATER
SYSTEM)
• Line plugs can be placed in the end of the
spreader tubes to help keep bugs out, but still
allow passage of water.
1/2” MPT ADAPTER
FLEX PVC RISER
Flow, GPH (LPH)
LAT. TEE
OR 90° ELL
2.5
(9.5)
2.0
(7.6)
1.5
(5.7)
1.0
(3.8)
0.5
(1.9)
0.0
Model FD-2020
Model FD-2010
0
25
(1.72)
50
(3.45)
75
(5.17)
100
(6.89)
Pressure, PSI (bars)
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
rev.080615
NonStop®
Drip Emitters
SL200 Series
• Barbed elbow outlet port for connecting
spreader tubing, if desired.
• Industry standard 1⁄ 2" FPT connection in cap.
• Silicone O-ring inside cap for leak-free
connections.
• Constructed of tough engineering grade plastic
with UV inhibitors.
Stock No
6034
6035
6036
6037
Model No.
SL206
(Green Port)
SL210
(Blue Port)
SL220
(Red Port)
SL230
(Yellow Port)
FINISH
GRADE
LAT. TEE OR ELL
0.6 GPH
(2.3 LPH)
1.0 GPH
(3.8 LPH)
2.0 GPH
(7.6 LPH)
3.0 GPH
(11.4 LPH)
* Nominal Flow @ 20 PSI
Installation Examples
DRIP EMITTER
BOWSMITH MODEL
SL200
(1⁄ 2" FPT FIELD
INSTALLED
AFTER FLUSHING
WATER SYSTEM)
Nominal Flow*
WATER BASIN INSTALLED AROUND PLANT PIT
ROOTBALL OF SHRUB, GROUND COVER OR TREE
BOWSMITH NonStop SL200
SERIES EMITTER
DISTRIBUTION
TUBING
(CUTAWAY SHOWS
BARB CONNECTOR
AFTER FIELD
INSTALLATION)
BOWSMITH “SFT-12”
ASSEMBLY (1/2”)
RE-BAR J-HOOK
1/2" MPT
ADAPTER / FLEX
PVC RISER
(CUTAWAY
SHOWS
EMITTER IN
PLACE)
1/2” SCH 40 UVR PVC
LATERAL LINES
INSTALLED ON
FINISHED GRADE
FINISH GRADE ON
SLOPE
ML200 Series
• Six open outlets. Each maintains its own flow
path .
• 1/2" FPT inlet.
• Includes full set (6 each) of elbow/outlet caps,
and line plugs.
• One-piece elbow/outlet cap fixes position of
elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of
spreader tubing.
Stock No
7068
7069
7071
Model No.
Nominal Flow*
ML206
0.6 GPH
(2.3 LPH)
1.0 GPH
(3.8 LPH)
2.0 GPH
(7.6 LPH)
each open outlet
(Green Cap)
ML210
(Blue Cap)
ML220
(Red Cap)
* Nominal Flow @ 20 PSI
• The elbow is easily reversed to cap off any
unused outlets.
• Line plugs can be placed in the end of the
spreader tubes to help keep bugs out, but still
allow passage of water.
NonStop Drip Emitters
Flow, GPH (LPH)
Nominal Performance
4.0
(15.1)
3.0
(11.4)
2.0
(7.6)
1.0
(3.8)
0
10
(0.69)
Notes
2.0 GPH Models*
1.0 GPH Models*
15
(1.03)
20
(1.38)
0.6 GPH Models*
25
30 Pressure, PSI
(1.72)
(2.07)
(bars)
• Manufacturer’s variation,
Cv: ≤0.05
• 30-mesh filtration and 15
PSI emitter operating pressure are the recommended minimums for a NonStop emitter system.
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
rev.080615
NonStop®
Drip Emitters
Typical Installation Examples
TYPICAL INSTALLATION
WATER BASIN INSTALLED AROUND PLANT PIT
ROOTBALL OF SHRUB, GROUND COVER OR TREE
REFER TO PLANTING PLANS FOR PLANTING DETAILS
BOWSMITH NonStop SL200 SERIES EMITTER
BOWSMITH “SFT-12” ASSEMBLY (1/2”)
RE-BAR J-HOOK
1/2” SCH 40 UVR PVC LATERAL LINES
INSTALLED ON FINISHED GRADE
FINISHED GRADE ON SLOPE
BOWSMITH “SUPER FLEX” TUBE ASSEMBLY
BOWSMITH “SL200” EMITTER
NOTE:
DRIP EMITTER SHALL BE PLACED TO DROP 8”-12” UPHILL FROM ROOTBALL.
PVC LATERAL SUPPLY LINES SHALL RUN PARALLEL TO SLOPE WITH DRIP
EMITTER LINES RUN PERPENDICULAR TO SLOPE AS SHOWN ABOVE.
P.O. Box 428 • Exeter, CA 93221 USA
Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648
P: (559) 592-9485 F: (559) 592-2314
www.bowsmith.com
rev.080615