Erhard BMW - Bloomfield Township
To: Planning Commission From: Patti Voelker, Director of Planning, Building and Ordinance Subject: Public Hearing for Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road for a New Erhard BMW Dealership (19-06-226-010) Date: April 1, 2015 CC: Leo Savoie, Township Supervisor PROPOSAL DESCRIPTION Maptel Properties, LLC/Erhard BMW is seeking a rezoning request as part of their site plan for redevelopment of the former Ford Dealership property, located at 1845 Telegraph Road on the northeasterly side of Telegraph Road, north of Square Lake Road. The site plan shows expansion of the existing building and site improvements to accommodate the new dealership operation (87,119 sf). The purpose of the rezoning request is to rezone the rear portion of the property from ML Light Manufacturing to B-3 General Business to be consistent with the balance of the property currently zoned to the B-3 classification. On July 8, 2014, the ZBA granted a variance request to allow Erhard BMW to occupy the former Ford Dealership property by continuing the property’s nonconforming lot size of 8.02 acres with a minimum of 10 acres required for new car sales agencies. LEGAL DESCRIPTION – 2.25 Total Acres Commencing at the Northeast corner of said Section 6; thence S0130-00 E, 1264.98 feet along the east line of said Section 6 to the Point of Beginning; thence S00-35-29 E, 374.11 feet to the northwesterly corner of “Bloomfield Park”, Oakland County Condominium Plan #1718, as recorded in Liber 35092, Page 207, Oakland County Records; thence along the westerly line of said condominium, S01-4228 E, 245.20 feet; thence N49-50-45 W, 424.69 feet; thence N42-1340 E, 466.35 feet to the Point of Beginning. MASTER PLAN RECOMMENDATION The Master Plan Update as adopted by the Township in 2007 recommends that the subject property on the northeasterly side of Telegraph Road, north of Square Lake Road, be used for commercial businesses. The development policies of the Master Plan do not differentiate between the different business zoning classifications of B-1 Local Business District, B-2 Community Business District, B-3 General Business District, or B-4 Planned Business District. During the Master Plan Update process, the Ford Dealership site was found to be an acceptable commercial development with uses intended to serve passerby traffic. The Master Plan Future Land Use Map identifies this property as part of a recommendation to expand the commercial business zoning classification by rezoning Public Hearing: Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road April 1, 2015 Page 2 of 6 those portions identified with ML Light Manufacturing District classification for the specific parcels fronting on Telegraph Road. EXISTING ZONING The Township’s Zoning Ordinance specifies the allowable uses of land for each zoning district and further provides regulations to protect the public health, safety, and general welfare of the community. Of the four business zoning classifications, the B-3 General Business District is characterized by more diversified business types and is often located so as to serve a broader market area, and is typically mapped along the Woodward Avenue and Telegraph Road corridors. The B-3 General Business District allows retail businesses or service uses, office uses, and a variety of special land uses including vehicle dealerships. The subject parcel abuts the Honda Dealership and Lowe’s properties which are zoned in a similar fashion with a B-3 classification along Telegraph Road and the rear portion zoned ML District. The property to the south is Reimer Floors with a B-3 zone classification. PROPOSED ZONING Erhard BMW is asking for a change in zoning classification for the rear 2.25 acres zoned M-L Light Manufacturing to B-3 General Business to match the balance of the property. The change in zoning will result in the proposed northerly 10 ft. side parking setback complying with the B-3 setback requirements. The proposed southerly 4 ft. parking setback will still require a variance from the Zoning Board of Appeals. The applicant meets the location, height, and building setback requirements for the B-3 General Business District, except for the south side parking setback, fence height, and plantings setback. SITE PLAN STANDARDS FOR REVIEW Chapter 42, Article 6.0 Development Procedures, Section 42-6.1 requires that the following standards be addressed by the applicant as part of the Board’s consideration of a site plan. In the process of reviewing the site plan, the Planning Commission shall: A. Consider single-family development on the basis of a subdivision. Not applicable. B. Consider the location and design of driveways providing vehicular ingress to and egress from the site, in relation to streets giving access to the site, and in relation to pedestrian traffic. The site plan shows a reduction in the number of driveways along Telegraph Road from three to two driveways. The existing southerly driveway will allow continued truck turning movements, and general site access. The new northerly driveway is shown with a curbed island for right-in and right-out turning movements to prohibit any access to the northbound median crossover. A new right turn taper lane is also shown leading up to the northerly right-turn driveway. The proposed traffic circulation with a new dedicated right turn lane is supported by Mr. Labadie, the Township’s Traffic 2 Public Hearing: Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road April 1, 2015 Page 3 of 6 Engineer. It is further noted that any improvements within the MDOT’s Telegraph Road right-of-way will require review, approval, and permitting by MDOT. C. Consider the traffic circulation features within the site and location of automobile parking areas, and may make such requirements with respect to any matters as will ensure: a. Safety and convenience of both vehicular and pedestrian traffic both within the site and in relation to access streets. b. Satisfactory and harmonious relations between the development of the site and the existing and prospective development of contiguous land and adjacent neighborhoods. The site plan and traffic impact study were reviewed by Mr. Labadie, the Township’s Traffic Engineer, for parking and traffic access requirements. His report dated February 27, 2015 finds that the parking, traffic impacts, on-site circulation, and site access improvements are acceptable to service the proposed development. The 313 parking spaces exceed the 146 parking spaces required for the dealership operation. A total of 202 vehicle spaces are noted for inventory and display. D. The Planning Commission may further require landscaping, fences, and walls in pursuance of these objectives and same shall be provided and maintained as a condition of the establishment and the continued maintenance of any use to which they are appurtenant. The landscape plan was reviewed by the Township’s Landscape Architect, Michael J. Dul & Associates, Inc., for conformance with the Ordinance. The report dated February 17, 2015 concludes that the proposed landscape improvements meet the intent of the zoning ordinance and recommends approval subject to the applicant seeking the necessary variances. A masonry enclosure with a wood gate is shown to contain a trash compactor at the rear of the building. A loading area for the new building is located at the rear of the building, and within the vehicle inventory area as required. The roof top mechanical units will be set back from the building edge and screened from view by the building parapet wall. E. In recommending approval of the site plan to the Township Board, the Planning Commission may recommend marginal access drives. For a narrow frontage, which will require a single outlet, the Planning Commission may recommend that money in escrow be placed with the Township so as to provide for a marginal service drive equal in length to the frontage of the property involved. Occupancy permits shall not be issued until the improvement is physically provided or monies have been deposited with the Township Clerk. Not applicable. F. The Planning Commission shall require marginal access drives for all subdivisions having residential lots facing onto a major thoroughfare. Where practical, the Planning Commission shall require a rear lot relationship to major thoroughfares. Not applicable. 3 Public Hearing: Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road April 1, 2015 Page 4 of 6 STANDARDS FOR REVIEWING SPECIAL LAND USES The Township Board shall review each case individually based upon the standards set forth in Section 42-6.2 and, in addition, such uses, if approved, shall be subject to conditions, restrictions, and safeguards as are authorized by law and deemed to be necessary by the Township Board: A. Taking into consideration the size, location and character of the proposed land use, viewed within the context of surrounding land uses and land use planning for such area, the proposed use shall not be incompatible nor inharmonious, as determined by the application of generally accepted planning standards and/or principals, with: a. The surrounding uses; and/or b. The orderly development of the surrounding neighborhood and/or vicinity. The applicant meets the location, height, bulk and area, screening, landscaping, parking, and building setback requirements for the B-3 General Business District. Variances are required to exceed the 6 ft. fence height, provide parking within the required side setback, and for planting closer than 4 ft. to the property line for the transformer screening. B. The proposed use shall be of a nature that will make vehicular and pedestrian traffic no more hazardous than is normal for the district involved, taking into consideration vehicular turning movements in relation to routes of traffic, flow, proximity and relationship to intersections, adequacy of sight distances, location and access of offstreet parking and provisions for pedestrian traffic, with particular attention to minimizing child-vehicle interfacing. The reduction in the number of curb cuts along Telegraph Road and installation of the dedicated right turn lane will improve site access and traffic circulation as part of the right-of-way modifications to comply with MDOT requirements. C. The proposed use shall not unreasonably impact upon the surrounding property in terms of noise, dust, fumes, smoke, air, water, odor, light and/or vibration, and shall not unreasonably impact upon a person perceiving the operation in terms of aesthetics. Where such concerns can be remedied by way of design, construction and/or use, the proposed use shall be designed, constructed and used so as to eliminate the effects of the use which would otherwise substantiate denial thereof, taking into consideration the location, size, intensity, layout and periods of operation of such use. Noise –No additional noise is anticipated other than those customarily associated with a commercial use. Odor – No odors other than those customarily associated with a commercial use. Light – New parking lot lighting will be low profile, LED full cut–off fixtures, not to exceed 20 ft. in height as measured from grade, and to be directed downward to illuminate the parking area only. The rear exit doors shall be illuminated by a full cut-off wall pack fixtures. The revised photometric plan shows the level of illumination of the proposed front parking lot fixtures not to exceed 9.0 fc (footcandles) to meet the maximum provided throughout the balance of the property. 4 Public Hearing: Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road April 1, 2015 Page 5 of 6 Aesthetics – The proposed architectural design of the building compliments the design of the adjacent commercial buildings. D. The proposed use shall be such that the proposed location and height of buildings or structures and the proposed location, nature and height of walls, fences, and landscaping will not interfere with or discourage the appropriate development and use of adjacent land and buildings or unreasonably affect their value. The proposed new dealership meets the requirements for the B-3 General Business District. E. The proposed use shall relate harmoniously with the physical and economic aspects of adjacent land uses in regards to prevailing shopping habits, convenience of access by prospective patrons, continuity of development, and need for particular services and facilities in specific areas of the Township. The proposed commercial use of a BMW Dealership is compatible with the adjacent Honda Dealership and other retail service uses along Telegraph Road. F. The proposed use is so designed, located, planned and to be operated so that the public health, safety and welfare will be protected. The public’s health, safety and welfare are not impacted. G. The proposed use shall not cause substantial injury to the value of other property in the neighborhood in which it is to be located and will not be detrimental to existing and/or other permitted land uses in the zoning district. Bill Griffin, Township Assessor, indicates that the subject property is located on the east side of Telegraph Road north of Square Lake Road and is classified as commercial property by the Assessor’s Office. Preliminary analysis indicates that the surrounding commercial properties would not suffer from any external obsolescence caused by the proposed expansion of the subject property. The subject property abuts no residential property. Ultimately the market will determine any future accrued depreciation to properties abutting the subject property. Mr. Griffin concludes that the proposed expansion of the subject property would not create any substantial value changes to the neighboring properties. H. The proposed use shall not result in an impairment, pollution, and/or destruction of the air, water, natural resources and/or public trust therein. The development does not pose any negative environmental impact as presented. I. The proposed use shall not unreasonably burden the capacity of public services and/or facilities. No proposed impact to current public services. J. The proposed use shall have appropriate physical, visual and spatial characteristics based upon compatible design and architectural elements that relate harmoniously to 5 Public Hearing: Rezoning/Site Plan and Special Land Use Request for 1845 Telegraph Road April 1, 2015 Page 6 of 6 the design characteristics of area development, taking into consideration the design criteria set forth in Section 42-6.4. The architectural design of the building is consistent with the character of the Telegraph Road corridor. DEPARTMENT REPORTS The Township Departments of Assessor, Building, Fire, Engineering and Environmental Services, Ordinance, Public Works, and Police have had an opportunity to review the site plan and drawings, with their comments attached. Fire Department - No objections to the proposed project. Police Department – The Police department endorses the crime prevention measures proposed with the installation of perimeter security to include 8 ft. fencing, lighting, and property surveillance. Engineering and Environmental Services Department (EESD) – Engineering plans of the site improvements will need to be submitted upon Township Board approval, and prior to the issuance of a building permit, to meet stormwater management, water and sewer, and engineering site plan review standards. BUILDING DESIGN & SIGNAGE The exterior façade of the building will be comprised of glass and light grey metal panels with a white cornice, and metal framed windows and doors. The building elevations have been provided that reflect a building design that is architecturally compatible with surrounding businesses. The applicant will be required to submit signage plans to the Design Review Board for review and approval prior to installation. Signs shall comply with the B-3 General Business District sign requirements. DESIGN REVIEW BOARD RECOMMENDATION The Design Review Board reviewed the site plan, drawings and materials for the BMW Dealership on March 4, 2015 and forwarded the request to the Planning Commission and Zoning Board of Appeals, as follows: Motion by Barnett and supported by Devine to approve the site plan and design as submitted, and to forward to the Planning Commission and Zoning Board of Appeals, contingent upon compliance with all other Departmental requirements, including obtaining all necessary permits. The motion was carried unanimously. PLANNING COMMISSION CONSIDERATION It is recommended the Planning Commission hold the public hearing to receive any comments from the public on the proposed rezoning request as part of the site plan for redevelopment of the former Ford Dealership property, located at 1845 Telegraph Road for a new Erhard BMW Dealership, and forward a recommendation to the Township Board for their consideration. 6 February 27, 2015 VIA EMAIL Ms. Patricia Voelker Planning and Building Director Charter Township of Bloomfield 4200 Telegraph Road Bloomfield Hills, MI 48303 RE: Erhard BMW Site Plan and TIA Review Telegraph Road Bloomfield Township, MI Dear Ms. Voelker: Fleis & VandenBrink (F&V) staff has completed our review of the updated site plan dated February 2, 2015 and received February 26, 2015 for this proposed project. Based on these reviews, we have the following comments and observations: • • • • Access to the site will be provided by an existing south driveway and new north driveway with two way traffic around the building. As previously recommended the project engineer has simulated truck (WB-62) movement around the site and shown this data on plan sheet P-3.1. Based upon this data a typical semi-truck will be able to adequately move around the building in either direction; however, the location of proposed trees, proposed sign, and an existing block wall may create a challenging movement at the southeast corner of the building. The proposed north driveway will align with an existing south bound to north bound cross over. To mitigate poor LOS at this location, the consultant has recommended a right-in right-out only driveway as well as new “Left Turn Only” signage at the cross over. Also, based upon MDOT guidelines, a full-width right turn lane is recommended for this driveway. As previously recommended the project engineer has included these modifications in the proposed site plan. Based upon MDOT guidelines, a right turn taper is recommended at the existing south driveway. As previously recommended the project engineer has included these modifications in the proposed site plan. Since Telegraph Road is under the jurisdiction of MDOT, a review and approval of the driveways will be required. The plan and TIS should be reviewed by MDOT and the access driveways constructed consistent with MDOT guidelines. 821790 Bloomfield Twp Erhard BMW Site Plan and TIA Review FINAL Update 27725 Stansbury Boulevard, Suite 150 Farmington Hills, MI 48334 P: 248.536.0080 F: 248.536.0079 www.fveng.com Patti Voelker | Bloomfield Township │ February 27, 2015 Page 2 of 2 We hope that this review satisfies the Township’s current planning needs regarding this project. If you have any questions or concerns, please contact our office. Sincerely, FLEIS & VANDENBRINK Michael J. Labadie, PE Group Manager 821790 Bloomfield Twp Erhard BMW Site Plan and TIA Review FINAL Update February 17, 2015 Ms. Patricia Voelker Planning & Building Director Bloomfield Township 4200 Telegraph Road Bloomfield Hills, MI 48303-0489 PHO: (248) 433-7795 FAX: (248) 433-7729 RE: LANDSCAPE REVIEW PROJECT: Erhard BMW 1845 Telegraph Rd. Bloomfield Township, MI DOCUMENTS: Site Plans- Sheet Nos. P-1.0-P-4.0 Dated 02-02-15 Prepared by Professional Engineering Associates Tree Preservation Plan- Sheet No. TREE-1.0 Dated 02-02-15 Prepared by Professional Engineering Associates Landscape Plans- Sheet No. L-1.0 Dated 02-02-15, Revised 02-16-15 Prepared by Professional Engineering Associates Dear Ms. Voelker: In accordance with your request, we have reviewed the above referenced landscape plans. Our comments are as follows: EXISTING TREE PRESERVATION/REPLACEMENT 1.) The tree replacement information shown on the charts on Sheet L-1.0 have been updated and all information is correct. Items to be addressed: No action required. 2.) There is a total of 642 caliper inches required for replacement. The landscape calculations chart on Sheet L-1.0 shows that there are 39 inches being replaced along Telegraph Road and 0 trees proposed within the woodland area for replacement. There is a deficit of 603 caliper inches that have not been replaced. The plan indicates that the owner must contribute to the Township Woodland Tree Fund for the deficit in replacement inches. Items to be addressed: No action required. The applicant indicates requirement to contribute to the Woodland Tree Fund for above deficit. February 17, 2015 Landscape Review/ Erhard BMW 1845 Telegraph Rd., Bloomfield Twp., MI Page Two TELEGRAPH GREENBELT 1.) The 25’ greenbelt along Telegraph is intended for landscape and buffer between thoroughfare(s) and the proposed parking. Although there are large deciduous trees along Telegraph, there aren’t any shrubs being proposed along the greenbelt to screen the parking spaces. Since the parking is intended for inventory display only, this is an acceptable solution. Items to be addressed: No action is required. PARKING LOT LANDSCAPE 1.) Section 42-5.3 Off-Street Parking Space layout, Standards, Construction and Maintenance of the zoning ordinance indicates the following requirements: (9)c. “Each planting bed shall be a continuous earth-planting bed at least eight (8) feet wide and a minimum of three hundred (300) square feet in area. Landscape materials shall be planted no closer than four (4) feet to the property line.” The applicant has relocated the two proposed parking lot trees (Gingko biloba) so they are no longer on islands that do not meet ordinance size requirements, thus they no longer need to request a variance. The new locations are, however, nestled within proposed parking lot trees of a different variety. Item to be addressed: No action required. We would recommend, however, that the applicant considers changing the proposed species of these two trees to match the proposed Honeylocust trees that surround them to create more continuity throughout the site. 2.) According to the Landscape Calculations on Sheet L-1.0, there is 52 parking lot trees required based on 313 parking spaces outside of the inventory parking area. The plan shows that 52 trees have been proposed to meet this requirement, which satisfies the parking lot tree requirement based on 313 parking spaces. Items to be addressed: No action required. GENERAL SITE 1.) A note on Sheet L-1.0 indicates that “Irrigation system to have separate zones for lawn, parking islands, and plant beds with different control moisture level adjustments per zone as required.” Items to be addressed: No action required. February 17, 2015 Landscape Review/ Erhard BMW 1845 Telegraph Rd., Bloomfield Twp., MI Page Three 2.) Section 42-5.6 Plant Material of the zoning ordinance indicates the following requirement: (1)a. “Plant materials shall not be placed closer than four (4) feet from the fence line or property line.” The applicant has placed a note on the plans indicating this requirement. Items to be addressed: No action required. 3.) Typically the electrical transformer should be screened on all sides, but due to the location of the proposed transformer it is impossible, for clearance reasons, to plant an evergreen screen around all four sides of the transformer. Items to be addressed: Providing the Township approves the location of the transformer, no action will be required. 4.) The applicant is proposing to re-zone the rear parking lot area from ML to B-3, which reduces the side yard setback from 20 feet to 10 feet. The proposed parking falls 3.9 feet within the 10 foot side yard setback line that spans the entire length of the rear lot line. Items to be addressed: A variance will be required to install parking within the required parking lot setback. SUMMARY Based on review of the revised drawings, sheet P-1.0 thru P-4.0, L-1.0, and TREE-1.0 prepared by Professional Engineering Associates dated 02-02-15, and revised on 02-16-15, the proposed landscape improvements meet the intent of the zoning ordinance and require the following variances and comments: 1.) Apply for and secure required variance for parking within the required side yard setback line. 2.) Secure permit for tree removals and contribute to the Woodland Tree Fund for deficit in replacements provided. Feel free to contact me at (248) 644-3410 x 24 if you have questions or concerns about any of the above comments and/or recommendations. Respectfully submitted, MICHAEL J. DUL & ASSOCIATES, INC. Wendi Belcher REVISIONS 2/16/15 DATE 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION ERHARD BMW CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DES. DB PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN COVER SHEET ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: N.A. DRAWING NUMBER: NOT FOR CONSTRUCTION P-1.0 REVISIONS DATE No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DES. DB PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN TOPOGRAPHIC SURVEY ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION P-2.0 REVISIONS 2/23/15 2/16/15 DATE 2 DLB DLB ADD DECORATIVE FENCE DETAIL 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DES. DB PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN SITE PLAN ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DECORATIVE FENCE DETAIL NOT FOR CONSTRUCTION DRAWING NUMBER: P-3.0 REVISIONS 2/16/15 DATE 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DES. DB PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN TRUCK TURN DETAIL ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION P-3.1 REVISIONS 2/16/15 DATE 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DB DES. PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN PRELIMINARY GRADING PLAN ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION P-4.0 REVISIONS 2/16/15 DATE 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DB DES. PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN PRELIMINARY UTILITY PLAN ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION P-5.0 REVISIONS DATE No. BY CHK DESCRIPTION CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DES. DB PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN NOTES AND DETAILS ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: N.A. DRAWING NUMBER: NOT FOR CONSTRUCTION P-6.0 2/16/15 DATE = EXISTING TREES TO REMAIN SEE LANDSCAPE PLAN L-1 FOR TREE PROTECTION FENCING = TREES TO BE REMOVED SEE SHT. L-1.0 FOR TREE REPLACEMENTS REVISIONS 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION KEY: CAUTION!! THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG EXISTING TREE LIST - WOOD LAND AREA TREE WITH LINE THROUGH PLANT ITEM = TO BE REMOVED 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES P.M. PEA SUR. DB/DRW DN. DB DES. PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN TREE WITH LINE THROUGH PLANT ITEM = TO BE REMOVED TREE PRESERVATION PLAN ERHARD BMW EXISTING TREE LIST - TELEGRAPH ROAD 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW JPB 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION TREE-1.0 REVISIONS 2/16/15 DATE 1 DLB DLB TOWNSHIP SITE PLAN REVIEW COMMENTS No. BY CHK DESCRIPTION KEY: = PARKING LOT TREES R = REPLACEMENT TREES = EXISTING TREES TO REMAIN WITH TREE PROTECTION FENCING = SCREENING SHRUBS CAUTION!! = 3-4" DIA, AT 4" DEPTH RIVER ROCK OVER WEED FABIRC THE LOCATIONS AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THIS DRAWING ARE ONLY APPROXIMATE. NO GUARANTEE IS EITHER EXPRESSED OR IMPLIED AS TO THE COMPLETENESS OR ACCURACY THEREOF. THE CONTRACTOR SHALL BE EXCLUSIVELY RESPONSIBLE FOR DETERMINING THE EXACT UTILITY LOCATIONS AND ELEVATIONS PRIOR TO THE START OF CONSTRUCTION. = SOD LAWN TO BE IRRIGATED WITH AUTOMATIC UNDERGROUND SYSTEM TYP. (CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE. ) = PERENNIAL/ SHRUBS BY OWNER PLANT BEDS TO BE IRRIGATED WITH AUTOMATIC UNDERGROUND SYSTEM TYP. NOTE: IRRIGATION SYSTEM TO HAVE SEPARATE ZONE FOR LAWN, PARKING ISLANDS AND PLANT BEDS WITH DIFFERENT CONTROL MOISTURE LEVEL ADJUSTMENTS PER ZONE AS REQUIRED. THIS DRAWING AND DESIGN ARE THE PROPERTY OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. THEY ARE SUBMITTED ON THE CONDITION THAT THEY ARE NOT TO BE USED, REPRODUCED, OR COPIED, IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS, WITHOUT THE PRIOR WRITTEN CONSENT OF PROFESSIONAL ENGINEERING ASSOCIATES, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 2007 PROFESSIONAL ENGINEERING ASSOCIATES, INC. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MISS DIG 3 WORKING DAYS BEFORE YOU DIG CALL MISS DIG 1-800-482-7171 (TOLL FREE) PROFESSIONAL ENGINEERING ASSOCIATES ORIGINAL ISSUE DATE: FEB. 2, 2015 PEA JOB NO. 2014-211 SCALE: 1"=40' DRAWING NUMBER: NOT FOR CONSTRUCTION L-1.0 JPB P.M. PEA SUR. DB/DRW DN. DB DES. PART OF THE NE 1/4 OF SECTION 6, T. 2 N., R. 10 E., BLOOMFIELD TOWNSHIP, OAKLAND COUNTY, MICHIGAN PRELIMINARY LANDSCAPE PLAN ERHARD BMW 4065 WEST MAPLE ROAD BLOOMFIELD HILLS, MI 48301 ERHARD BMW 2430 Rochester Ct. Suite 100 Troy, MI 48083-1872 Phone: (248) 689-9090 Fax: (248) 689-1044 website: www.peainc.com D-Series Size 1 Catalog Number LED Area Luminaire DSX1 LED 60C 530 40K T5W MVOLT DWHXD Notes Type BACK-A Hit the Tab key or mouse over the page to see all interactive elements. Introduction The modern styling of the D-Series is striking yet unobtrusive - making a bold, progressive statement even as it blends seamlessly with its environment. The D-Series distills the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The outstanding photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. It is ideal for replacing 100 – 400W metal halide in pedestrian and area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Specifications W 1.2 ft2 EPA: W (0.11 m2) 33” Length: (83.8 cm) 13” Width: L L (33.0 cm) Height: 7-1/2” Weight (max): 27 lbs H H (19.0 cm) (12.2 kg) Ordering Information 60C DSX1 LED Series Drive current Forward optics 30C 30 LEDs (one engine) 40C 40 LEDs (two engines) 60C 60 LEDs (two engines) Rotated optics 1 60C 60 LEDs (two engines) Template #8 Drilling 530 LEDs DSX1 LED EXAMPLE: DSX1 LED 60C 1000 40K T3M MVOLT SPA DDBXD 530 530 mA 700 700 mA 1000 1000 mA (1 A) Color temperature 30K 40K 50K AMBPC Top of Pole 0.400” (2 PLCS) 2.650” Distribution 3000 K (80 CRI min.) 4000 K (70 CRI min.) 5000 K(70 CRI) Amber phosphor converted 2 DWHXD MVOLT Voltage T1S T2S T2M Type I short Type II short Type II medium T3S Type III short T3M Type III medium T4M Type IV medium TFTM Forward throw medium T5VS Type V very short T5S Type V short T5M Type V medium T5W Type V wide MVOLT 3 120 3 208 3 240 3 277 3 347 4 480 4 Mounting DM19AS DM28AS DM49AS Single unit 2 at 180° 4 at 90° * DM29AS DM39AS DM32AS 2 at 90° * 3 at 90° * 3 at 120° ** Example: SSA 20 4C DM19AS DDBXD Ordered and shipped separately. Accessories Visit Lithonia Lighting’s POLES CENTRAL to see our wide selection of poles, accessories and educational tools. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 18 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 18 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 18 SC U Shorting cap 18 DSX1HS 30C U House-side shield for 30 LED unit DSX1HS 40C U House-side shield for 40 LED unit DSX1HS 60C U House-side shield for 60 LED unit PUMBA DDBXD U* Square and round pole universal mounting bracket adaptor (specify finish) Mast arm mounting bracket adaptor (specify finish) 6 KMA8 DDBXD U *Round pole top must be 3.25” O.D. minimum. **For round pole mounting (RPA) only. Tenon Mounting Slipfitter ** Tenon O.D. Single Unit 2 at 180° 2 at 90° 3 at 120° 3 at 90° 4 at 90° 2-3/8” AST20-190 AST20-280 AST20-290 AST20-320 AST20-390 AST20-490 2-7/8” AST25-190 AST25-280 AST25-290 AST25-320 AST25-390 AST25-490 4” AST35-190 AST35-280 AST35-290 AST35-320 AST35-390 AST35-490 For more control options, visit DTL and ROAM online. Control options Shipped included SPA Square pole mounting RPA Round pole mounting WBA Wall bracket SPUMBA Square pole universal mounting adaptor 5 RPUMBA Round pole universal mounting adaptor 5 KMA8 Mast arm DDBXD U mounting bracket adaptor (specify finish) 6 DSX1 shares a unique drilling pattern with the AERIS™ family. Specify this drilling pattern when specifying poles, per the table below. 0.563” 1.325” T5W 40K Shipped installed PER NEMA twist-lock receptacle only (no controls) 7 DMG 0-10V dimming driver (no controls) 8 DCR Dimmable and controllable via ROAM® (no controls) 9 DS Dual switching 10.11 PIR Motion sensor, 8-15’ mounting height 12 PIRH Motion sensor, 15-30’ mounting height 12 BL30 Bi-level switched dimming, 30% 11,13 BL50 Bi-level switched dimming, 50% 11,13 Other options Shipped installed HS Houseside shield 14 WTB Utility terminal block 15 SF Single fuse (120, 277, 347V) 16 DF Double fuse (208, 240, 480V) 16 L90 Left rotated optics 17 R90 Right rotated optics 17 DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white NOTES 1 Rotated optics only available with 60C. 2 AMBPC only available with 530mA or 700mA. 3 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). Specify 120, 208, 240 or 277 options only when ordering with fusing (SF, DF options). 4 Not available with single board, 530mA product (30C 530, or 60C 530 DS). Not available with DCR, BL30 or BL50. 5 Available as a separate combination accessory: PUMBA (finish) U. 6 Requires “SPA” mounting option. Must be ordered as a separate accessory; see Accessories information. For use with 2-3/8” mast arm (not included). 7 Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Not available with DS option. 8 DMG option for 347v or 480v requires 1000mA 9 Specifies a ROAM® enabled luminaire with 0-10V dimming capability; PER option required. Not available with 347 or 480V. Additional hardware and services required for ROAM® deployment; must be purchased separately. Call 1-800-4426745 or email: [email protected]. N/A with BL30, BL50, DS, PIR or PIRH. 10 Requires 40C or 60C. Provides 50/50 luminaire operation via two independent drivers on two separate circuits. N/A with PER, DCR, WTB, PIR, or PIRH. 11 Requires an additional switched circuit. 12 PIR specifies the SensorSwitch SBGR-10-ODP control; PIRH specifies the SensorSwitch SBGR-6-ODP control; see Motion Sensor Guide for details. Dimming driver standard. Not available with DS or DCR. 13 Dimming driver standard. MVOLT only. Not available with DCR. 14 Also available as a separate accessory; see Accessories information. 15 WTB not available with DS. 16 Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. 17 Available with 60 LEDs (60C option) only. 18 Requires luminaire to be specified with PER option. Ordered and shipped as a separate line item from Acuity Brands Control. One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com © 2011-2014 Acuity Brands Lighting, Inc. All rights reserved. Finish (required) D-Series Size 2 Catalog Number LED Wall Luminaire Notes Type DSXW2 LED 30C 1000 40K T4M MVOLT DWHXD WHITE FINISH TYPE WALL-A Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications Luminaire Back Box (BBW) 18-1/2” Weight: Width: 21 lbs (9.5 kg) (47.0 cm) 10” Depth: 7-5/8” 1-1/2” (3.8 cm) 4” Height: (19.4 cm) WALL SCONCE (Back Box Wall) MOUNTING WALL SCONCE BBW (Back BoxBBW Wall) MOUNTING (10.2 cm) W D 1 lbs (0.5 kg) (14.0 cm) Depth: (25.4 cm) Height: 5-1/2” BBW Weight: Width: 5-1/2 For 3/4” NPT side-entry conduit 1-1/2 5-1/2 H H 4 D 1-1/2 4 W Ordering Information DSXW2 LED Series DSXW2 LED 30C LEDs 20C 20 LEDs (two engines) 30C 30 LEDs (three engines) 1000 Drive Current 350 530 700 1000 350 mA 530 mA 700 mA 1000 mA (1 A) The D-Series Wall luminaire is a stylish, fully integrated LED solution for building-mount applications. It features a sleek, modern design and is carefully engineered to provide long-lasting, energy-efficient lighting with a variety of optical and control options for customized performance. With an expected service life of over 20 years of nighttime use and up to 76% in energy savings over comparable 400W metal halide luminaires, the D-Series Wall is a reliable, low-maintenance lighting solution that produces sites that are exceptionally illuminated. EXAMPLE: DSXW2 LED 30C 700 40K T3M MVOLT DDBTXD 40K Color temperature 30K 40K 50K AMBPC 3000 K 4000 K 5000 K Amber phosphor converted T4M Distribution T2S T2M T3S T3M T4M TFTM ASYDF Type II Short Type II Medium Type III Short Type III Medium Type IV Medium Forward Throw Medium Asymmetric diffuse DWHXD MVOLT Voltage Mounting MVOLT 1 120 1 208 1 240 1 277 1 347 2 480 2 Shipped included (blank) Surface mounting bracket Shipped separately 3 BBW Surfacemounted back box (for conduit entry) Control Options Shipped installed PE Photoelectric cell, button type 4 PER NEMA twist-lock receptacle only (no controls) DMG 0-10V dimming driver (no controls) DCR Dimmable and controllable via ROAM® (no controls) 5 PIRH 180° motion/ ambient light sensor, 15-30’ mtg ht 6 Other Options Shipped installed SF Single fuse (120, 277, 347V) 7 DF Double fuse (208, 240, 480V) 7 HS House-side shield 3 SPD Separate surge protection 8 Shipped separately 3 BSW Bird-deterrent spikes WG Wire guard VG Vandal guard 2 3 4 5 6 7 8 9 DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DSSXD Sandstone DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white DSSTXD Textured sandstone Accessories NOTES 1 Finish (required) MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). Specify 120, 208, 240 or 277 options only when ordering with fusing (SF, DF options), or photocontrol (PE option). Available with 30 LED/700mA options only (DSXW2 LED 30C 700). DMG option not available. Also available as a separate accessory; see Accessories information. Photocontrol (PE) requires 120, 208, 240 or 277 voltage option. Not available with motion/ambient light sensors (PIR or PIRH). Specifies a ROAM® enabled luminaire with 0-10V dimming capability; PER option required. Not available with 347V, 480V or PIRH. Additional hardware and services required for ROAM® deployment; must be purchased separately. Call 1-800-442-6745 or email: [email protected]. Specifies the Sensor Switch SBGR-6-ODP control; see Motion Sensor Guide for details. Includes ambient light sensor. Not available with “PE” option (button type photocell) or DCR. Dimming driver standard. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. See the electrical section on page 2 for more details. Requires luminaire to be specified with PER option. Ordered and shipped as a separate line item. Ordered and shipped separately. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 9 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 9 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 9 SC U Shorting cap 9 DSXWHS U House-side shield (one per light engine) DSXWBSW U Bird-deterrent spikes DSXW2WG U Wire guard accessory DSXW2VG U Vandal guard accessory DSXW2BBW DDBXD U Back box accessory (specify finish) One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com © 2012-2014 Acuity Brands Lighting, Inc. All rights reserved.