CoreNet tm Networked Lighting Control Components Catalog Complete networked control of individual rooms to global campuses Fastest Easiest Best 105.6 CoreNet tm Fastest, Easiest, Best in Networked Lighting Control Fastest Minimize errors and field time with simple two wire network. Easiest Control one room or an entire campus with a few standard components. Best Outstanding energy savings, user control, and system management. Featured Products LS230 - Integrated room controller provides occupancy and daylighting functions in a package small enough to mount directly on light fixtures. TR218 - Programmable controls work right out-of-the-box with simple test functions. PPUV Relay - 100-277v universal voltage 20A lighting relays connects directly to the LS230 to relay control without homeruns. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page iii 105.7.2 SYSTEM ARCHITECTURE Build full-function building-wide networks with just two wires and a handful of addressable components. 9 1 10 2 5 7 3 11 4 6 8 13 12 Build powerful, robust networks using just two standard building wires run free with Class 2 cable for retrofit or inside the lighting power conduit for new construction. 1 DALI Network 2 Simplify installation with full-function room controllers mountable directly on light fixtures Room Controllers or acoustic ceiling tile. 3 Distributed Relays Replace expensive home runs with distributed relays that put the relay where the load is. 4 User Controls Get started fast with simple, consistent out-of-the box operation. Line-Voltage Dimming 0-10v Zone Controller Addressable Ballasts Add line-voltage incandescent and LEDs lighting with full function dimming, scenes, and group capacity. Maximize simplicity and flexibility and eliminate hard-wired switch legs with addressable ballasts. 8 Relay Panels Control site lighting and other centralized circuits with addressable relay panels. 9 Mount this hand-sized network interface on a standard 11B electrical box and control up to Network Interface 128 relays, ballasts, dimmers, or 0-10v zones and 128 room or user controllers. 10 Trunk Network Plug together up to 256 RT03 network interfaces to create building-wide systems via a highspeed TCP/IP backbone. 11 System Server Maintain the system database in a central location for easy access. 12 Internet Connect from anywhere the Internet reaches to control, configure, or query the system. 13 Software Manage, operate, schedule, and configure with CoreNet’s intuitive, easy-to-use software. 5 6 7 Integrate 0-10v ballasts into the system with these full-function addressable controllers. Page iv ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 CORE PRODUCTS Pg 1 Zone Controller - Dual tech occupancy, vacancy, and daylighting Pg 2-7 controller in a compact package small enough to mount directly on light fixtures. User Controls - Put users in charge with dimming, scenes, and on/off control with programmable user controls. ACCESSORIES Pg 8-10 Pg 11 Pg 12-14 Gateways & Relay Drivers - Expand the core system with gateway Interfaces to 0-10v dimming ballasts, relays, external sensors, and BAS systems. Line Voltage Dimmers– Add track lights, and other line voltage lighting into dimmable lighting zones with full DALI functionality. Pg 15 Relays– Switch site lighting and distributed loads with CoreNet compatible relays relay panels. Pg 16-23 Bus Supplies and Trunk Networking– Create full building Pg 24-27 lighting networks with DALI Bus Supplies, System Servers, and Network Switches. Mounting Plates– Locate TR gateway controls in plenum spaces and create field assembled bus supply cabinets. Pg 28 Software - Commission, configure, manage, and schedule with CoreNet’s comprehensive suite of user friendly, intuitive software. Pg 29-33 ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page v 105.7.2 Core Products LS230 - DALI Zone Controller Page 2 TR218 - 2 or 4 button DALI wired user control. Page 8 Page 1 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.6 LS230 - DALI Zone Controller Occupancy and daylighting controller with built-in sensors. Made in USA CA Title 24 Certification Categories: ADC, MLO, MOS, OSM, PCD The LS230 zone controller delivers exceptional performance in a package small enough to be mounted directly on light fixtures and with the unparalleled simplicity of two-wire connections. LS230 - Actual Size (1.66” sq) KEY FEATURES Integrates occupancy, daylighting, and user control into a single package. Small enough to mount directly on light fixtures. Self aligns to curved surfaces as small as 4” dia. Mounts with adhesive or threaded nut. Connects directly to the DALI bus. Eliminates external sensor wires. Provides network level configuration and management of all settings including light sensor range. Automatically coordinates mulEnergy Efficiency and tiple motion sensors and user User Comfort controls into a single zone. The LS230 has been designed to meet or Supports both DALI ballasts exceed the most rigorous and relay switched zones. energy regulations with Integrates with the full line of full-featured vacancy, CoreNet controls to allow occupancy, and dayligintng control. creation of full-function building-wide lighting control systems. Motion Sensor Available with four footprints for cubicals to high-bay coverage. Multiple sensors can be used together to provide integrated coverage of any size space. Supports both vacancy and conventional auto-on logic. High electromagnetic noise resistance effectively eliminates cell phone interference. Both PIR and Acoustic dual tech sensing with network adjustable sensitivity. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Light Sensor Approximate human eye spectral response also filters out IR and UV light. Highly accurate and repeatable photo diode response. High temperature stability. High noise immunity. Network adjustable range setting and 10bit resolution assure accurate response over a wide range of light levels. tm Supports both LumeStat variable setpoint and conventional fixed setpoint logic. Digital Output Relay Driver Full DALI functionality supports scenes and remote control from other controllers. Relays can be used to create conventional switched zones either separately or in conjunction with dimming systems. All three relay types - NO, NC, EL– are supported and can be set using network commands. See specifications. Compatibility CoreNet Controllers - The LS230 is compatible with all CoreNet controllers including the TR218, 217, and 401. Third Part Controllers - The LS230 is with third party DALI compliant controllers including touchscreens and user controls. Note - energy certification restrictions may apply for some applications. Page 2 105.7.2 RT03 Bus Supply LS230 WIRING DIAGRAM Note 3 Vlt DALI Ballasts Vlt Blu Blu Red Red LS230 Mult-Sensor Notes 1. Power wires not shown. 2. DALI Wire Size - Varies. General recommendation is 18ga solid for Class 1 and 18-22ga stranded for Class 2. See CoreNet Wiring Guidelines plus equipment NEC, project, and local jurisdiction requirements. 3. Class 1 to Class 2 conversion box. 4. See CoreNet Wiring Guidelines for wiring recommendations. 5. DALI Load Ratings per Bus: 200mA continuous, 250mA Max, 12-22vdc, supports up to 64 DALI and 64 CoreNet Controller addresses. PPUV 20A Relays TR218 User Controls TR601 0-10v Drivers Class 2 field connection Tapping connector DALI Bus Class 1 or 2 Class 2, 18-22ga stranded TR51 Dimmers Device Leads, 22ga stranded DALI Bus LS230 FUNCTIONALITY Relay Functions General - The LS230 internal relay driver supports all applicable DALI commands including scenes and level cmds. Relay turns on with any DALI “on” command that results in a actual level greater than 0 and turns off with any cmd that results in an actual level = 0. Coordination - Relays may be used separately or in conjunction with dimming but are limited to on/off response. Scenes - Use any value above zero to turn on and any value equal to zero to turn off. Latching - Set latching mode with DALI System Fail value. SysFail = 0, Normally Open (NO) Default SysFail = 1-254, Normally Closed (NC) SysFail = 255, Electrically Latched (EL) Latching determines the state of the relay after a DALI bus power cycle. NO-open, NC-closed, and EL-the relay returns the its state before the power cycle. Occupancy DI Functions Factory Default Operation - The LS230 is configured to operate as a conventional occupancy sensor with relay control. No addressing is required but sensors can be configured with broadcast commands. All other modes require addressing to configure. Vacancy - (Manual-on/Auto-off) Consistent and intuitive operation plus highest energy rating. Requires manual controls like the CoreNet TR218. Recommended warning period of 120 seconds to allow occupants time to retrip the system before lights turn off. Occupancy - (Auto-on/Auto-off) Traditional “occupancy” function. Not compatible with manual controls. Restore - (Auto-off Disabled) Disables the auto-off function to create an Indefinite warning period. Use for private offices, hallways, and other spaces where low-level light is needed but turning lights off is not. Often used in conjunction with the CoreNet Scheduler. Occupancy Delay - Settable from 1-30 minutes (10minutes factory default) Warning Delay - Delay period before turning off. When entering Page 3 DALI Load Limits: 200mA continuous 250mA charging 64 DALI addresses 64 Controller addresses 16 DALI groups into this state dimmable lights are reduced to the minimum value and a relay connected to the DO will turn off. Motion detected during this period will return to the previous level and restart the Occupancy Delay timer. Acoustic Override Timer - Limits the time period that acoustic trips can maintain the Occupancy Delay state. DALI Occ Monitor Addresses - An off command to any of these DALI group addresses will cause the occupancy control to return to its idle state. DALI Transmit Group Address - Group addresses controlled by the Occupancy function. Daylight Functions Setpoint Mode Adaptive- Maintains user set light level. Use for classrooms, offices, conference rooms with manual controls with closed loop daylighting and one light sensor per daylight zone. Fixed- Conventional fixed setpoint control maintains a constant a setpoint. Use for open or public spaces without manual dimming control. Adjustment Rate - Determines how fast daylighting makes adjustments. Deadband - Range around setpoint. Switched daylighting requires are large deadband to prevent cycling. May also be used if fixed setpoint dimming mode to set range under setpoint for user dimming. DALI Monitor Addresses - Adjustments made to any of these DALI group addresses will initiate the calibration and Adaptive setpoint process. DALI Transmit Address - DALI group address controlled by the Daylight function. Adaptive Setpoint Delay - Time period after user adjustments have stopped before calibrating sensor and capture setpoint. Adaptive Setpoint Max - Maximum allowed setpoint value, Light Sensor Gain - Increase to 4 for low light levels. Button Operation Button 1 - Zrm, Room zone on/off.. Button 2 - Zocc, Occupancy zone on/off, Button 3 - Zday, Daylighting zone on/off ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 Indicator Lights Green - Controller - Blinks each time a button is pressed. Also used for identification during binding. Amber - Occupancy - Blinks each time motion is detected. Red - Daylight Indicator Light - Blinks each time a daylighting adjustment is made. OCCUPANCY SETTINGS 1.66 Name Range Default Enable Enable/Disable Disable PIR Input Enable/Disable Enable Acoustic Input Enable/Disable Disable Acoustic Trip Enable/Disable Disable Acoustic Sensitivity 0-100% 85 (about 20’ R) Occupancy Delay 0-30 min 10 Acoustic Override Timer 1-60 min 30 Warning Delay 0-240 sec 120 Role Master/Scout Master On Mode Manual/Auto Auto Off Mode Manual/Auto Auto DALI Occ Monitor Addresses 0-15 None Transmit Group Address 0-15 1.66 0.25 0.89 0.64 DAYLIGHT SETTINGS Name 0.047 Range Default Daylighting Enable/Disable Disable Setpoint Mode Fixed/Adaptive Fixed Fixed Setpoint 0-1023 1023 Deadbands 0-255 4 DALI Monitor Addresses 0-15 None DALI Transmit Address 0-15 Adaptive Setpoint Delay 0-255 sec 60 sec 0-1023 1023 0,2,4 0 Adaptive Setpoint Max Light Sensor Gain LS230 SPECIFICATIONS 1.00 1 Dimensioned in inches DALI Network Bus Power Supply: Must be CoreNet RT03 or equivalent DALI compliant Class 2 power supply of 11-22.5 vdc and 250mA max. LS230 DALI Load: 5 mA continuous. Relay Driver Digital Output Switch Type - Darlington transistor Electrical Isolation - 2500v Switch capacity - 24vdc,14mA max Vce drop - 2v. Physical Size: Body LxWxH,(1.66 x 1.66 x 0.64)inch, (42x42x16)mm. Mounting Hole: 1/4” diameter clearance. Hook-up Wire - 22AWG, 600v stranded copper 8” leads color coded for each function. Insulation type mPPE, CSA - AWM I A/ B, REACH Regulation (EC 1907/2006), RoHS compliant, UL AWM 11028, UL VW-1 Housing Material: 94v0 UL listed fire rated ABS/PC plastic. Color: White - NEMA WD1 White ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 4" mounting stem Ø0.276 Ø0.243 LS230 with Motion and Light Sensors Shown with Slight motion sensor. Electrical Anti-rotation & alignment tines Mounting: Nut - Self-threading Speed Nut: 1/4-20, with 11/16” dia flange and 7/16” nut size.. Adhesive - 1/16” thick foam and acrylic adhesive provides high bond strength to most surfaces including brushed Aluminum and low surface-energy materials such as polypropylene and powder coated metal. Environmental Operating Range: 0 to 55°C (32 to 131°F) Storage Temperature Range: -10 to 70°C (14 to 158°F) Relative Humidity: 15-85% non-condensing. Atmospheric Pressure: 86-106 kPa. Environment: The LS230 is neither water or dust proof. Avoid use in environments subject to excessive moisture, condensation, frost, and excessive levels of salt and dust. Overheating, oscillations (vibration), and shocks such as being dropped can cause the motion sensor to fail. Communication & Transmission Protocols DALI - IEC standard 60929 Ed. 2/CDV XDCP - Starfield Extended DALI Control Protocol Warranty: Limited 3-year warranty Page 4 105.7.2 LS230 MOUNTING The LS230 mounts on lighting fixtures, acoustic ceiling tile, and other flat or curved surfaces using either an adhesive foam collar or large flange nut self-threading nut. 4"minimum diameter Light fixture or other metal surface. Curved Metal Surface with Push-on Nut Flat or Lightly Curved Metal Surface with Adhesive 1 16" Anit-rotation tines. 11 16" large flange thread cutting nut. AcousticCeiling CeilingTitle Titlewith with Acoustic Thread-on Nut Push-on Nut adhesive foam collar Acoustic ceiling tile. 5 16" Mounting hole (Typical) Acoustic Ceiling Title with Adhesive ORDER NUMBER LS230- Motion Sensor 1 - Slight 2 - Standard 3 - Spot 4 - Wide Dual Tech _ _ _ Light Sensor D - Yes S - Std Range X - Extended Range _ DO (Relay) R - Yes R* - Addressing Activated Page 5 Examples: LS230-1DS LS230-1DSR LS230-R LS230-R* LS230-S LS230-X Slight PIR, Dual Tech, Standard light range Same as above with relay driver Relay driver without sensors DALI object activated (addressable) Light sensor, standard range Light sensor, extended range ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 LS230 CONFIGURATION SETTINGS The LS230 multi-sensor combines user control, occupancy, and daylighting into a single controller with the following configuration options and energy code ratings and certifications. User Functions - Defined here for the single button TR117 controller wired directly to a given LS230. Each LS230 can be set to a user different function so rooms with multiple LS230’s can have multiple user functions or interface with the TR218 and touchpanels for additional functions and an expanded user interface. Function User Occupancy Daylighting Energy Certification - Energy certifications given with CA Title 24 designations are also applicable to similar provisions in the IECC and ASHRAE energy codes. 1 2 3 Alt Action On 50% 4 /Off & R/L scroll 3M Cycle 50% 4 /Max/Min S13 Cycle Scenes 5 1,2,3 S46 Cycle Scenes 5 4,5,6 Dim X1 X X1 X1 Relay X1 X1 X1 Dim Relay MOS, MLO MOS, MLO NA 3 NA 3 MOS 2 NA 2 NA 3 NA 3 Vacancy Manual-on/Auto-off Occupancy Auto-on/Auto-off Vacancy Relay Manual-on/Auto-off Occupancy Relay Auto-on/Auto-off (Mode 4) (Mode 2) X7 X7 OSM, MOS 2 MOS 2 OSM, MOS 2 LumeStattm Dim Adaptive Setpoint 9 Conventional Dim Fixed Setpoint 9 Conventional Relay Fixed Setpoint (Mode 3) (Mode 2) (Mode 2) X X (Mode 4) (Mode 2) Dim X1 X1 Relay X1 X1 Operation Energy Certification 6 Daylighting - Both conventional fixed setpoint and LumeStat adaptive setpoint are supported for dimming and on/off for relays. 0 (Default) Operation Energy Certification 6 Occupancy Functions - Both vacancy and conventional occupancy functions are supported for both dimming and relay operation. Dim Relay Dim MOS, MLO MOS OSM 2 Operation X8 Relay Energy Certification 6 Dim ADC ADC Relay ADC Notes 1. 2. 3. 4. Function works with DALI dimming and relays separately or together except that: DALI relays do not respond to the interim dim period, they turn on at 100%, and they do not respond to R/L (raise/lower) commands. Bi-level relay switching is not supported. Scenes are not energy certified as their “on” level cannot be regulated but they are allowed when used in conjunction with MOS and MLO controls. 50% on level is network adjustable from 30-70%. Relays turn on at 100% and they do not respond to R/L commands. ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 5. 6. 7. 8. 9. Scene light level is a DALI ballast setting. Energy certifications dependent on coordinating user and occ control functions with same ratings. Includes10 min warning period with 3 flashes. Turns lights on and off. See page 11 for daylighting function comparison. Page 6 105.7.2 MOTION SENSOR PERFORMANCE SPECIFICATIONS Items 1. Slight 2. Standard 3. Spot 4. Wide Maximum Detection Distance (1) 2m (6.6’) 5m (16.2’) 5m (16.2’) 10m (32.8’) Horizontal 91º 100º 38º 110º Vertical 91º 82º 22º 93º Detection Zones 104 64 24 80 Movement Speed 0.8-1.2m/s (2.6ft/s) 0.8-1.2m/s (2.6ft/s) 0.5m/s (1.6ft/s) 0.8-1.2m/s (2.6ft/s) Detection Range Minimum Object 200mmx200m Size m 7.9”x7.9”) 700mmx250m m (27.6x9.8”) 700mmx250m (27.6x9.8”) Comments 1. Temperature difference between the target and background must exceed 4ºC (39.2ºF). 700mmx250m m (27.6x9.8”) LIGHT SENSOR PERFORMANCE SPECIFICATIONS Operating Specifications Sensor Linear response 1% accuracy photodiode Peak light detection frequency: 520nM Temperature stable UV and IR filtration Standard Range: 1200 Lux saturation. Suitable for most indoor applications up to 100fc. Extended Range: 25000 Lux saturation. Suitable for atriums and other high illumination applications up to 2000fc. ENERGY CODE COMPLIANCE The LS230 has been designed to meet or exceed interior lighting control requirements of any of the three most widely adopted USA energy codes: 2009 IECC Section 505, Standard 90.2-07 Section 9.1.1, and California’s Title 24 Sections 119, 131, 146. California Title 24 Section 119 Certifications Category Description Dim Relay ADC Automatic Daylighting Control DIM Dimmers MOS Vacancy Sensor MLO Notes X X NA NA 1 X No 2,3 Multi-level Occupancy Sensor X X 2,3 OSM Conventional auto-on/off occupancy sensor X X 4 PCD Interior Photosensor/ Photocontrol Device NA NA 5 Page 7 CA Title 24 Compliance Notes: 1. DIM Category - Not applicable to the LS230 or other CoreNet controllers as it refers to power control devices such as DALI ballasts and the TR51 dimmer. 2. Initial On Level - MOS & MLO applications are designed to work with manual controls by keeping track of the room state so that each time the lights are manually activated they turn on at 30-70% regardless of previous setting or how the lights turned off. 3. Manual Control - required for the MOS and MLO categories can be provided by any DALI compliant manual controller with an on/off function and initial on restrictions including the TR117 and TR218. See note 7 for scene restrictions. 4. OSM Category - Conventional auto-on/auto-off occupancy controls used without manual controls. See note 6 for manual off function. 5. Light Sensor - The LS230 is available as a stand-along light sensor for open and closed loop applications. 6. Manual-Off/Auto-on Restriction - Manual-off is restricted to the MOS and MLO categories because auto-on and manualoff functions are mutually exclusive in a room-aware system. 7. Scene Restrictions- All scene calls are assumed to be “on” commands as DALI scene commands cannot be definitively interpreted by the controller. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.6 TR218 - DALI Compliant Programmable User Control Made in USA Energy Management CA Title 24 Certified Categories: MOS,MLO user interface Rugged, spec-grade, Decora style controller designed for intuitive operation, easy installation, and optimal energy efficiency. DALI compliant and configurable from a range of easy to use templates. Use these versatile controllers as part of any DALI standard system or in conjunction with the LS230 sensor and other CoreNet equipment to create economical full-function, multi- TR218E with optional enunciation lights TR218 - Decora cover plate not included Available with 2 or 4 buttons, button enunciation lights, multiple configuration options, and 4 NEMA standard colors Key Features Configure directly with user buttons or indirectly over the DALI network. Peer to Peer control with unlimited multi-station operation. Compatible and coordinated with CoreNet computer controls. Energy Efficiency and Mounts in standard NEMA User Comfort switch boxes with standard The TR218 has been Decora style coverplates or designed to meet or exceed the most rigorous in 11B boxes on the MP2X energy regulations while mounting plate. concurrently providing Directly compatible with intuitive and consistent user control. DALI standard ballasts. Wires directly to the DALI network bus. Green controller indicator light and optional enunciator lights provide intuitive user feedback. Optional night light turns on when lights turn off. Specifications Electrical DALI bus load: 4.5 mA base controller power 3mA for optional enunciation lights 3mA for optional night light External sensor power—see sensor specifications Physical NEMA Decora form factor. Compatible with Decora single and multigang coverplates and with Lutron CW-1 screwless coverplates. Terminals and Wire: 5mm screw clamp terminals Copper conductors only Tighten to 4.5 in-lbs torque Wire size 12-22 AWG—Wire size larger than 18 AWG must be stranded. Caution: connecting solid wire larger than 18AWG may damage controller, make alignment difficult, and void the warranty. Housing & Button Cap Material: 94v0 UL listed fire rated ABS/ PC alloy plastic. Available Colors: NEMA WD1 White, Black, Gray, Ivory. Environmental Operating Temperature Range: 0 to 55°C, 32 to 131°F Storage Temperature Range: -10 to 85°C,14 to 185°F Relative Humidity: 20-90% non-condensing Communication & Transmission Protocol UL Listed Class 2 device. May not be installed in same DALI - IEC standard 60929 Ed. 2/CDV Annex E.4 and G electrical box with electrical power wires. DALI bus power supply must be CoreNet RT03 or equivalent Class 2 power supply that conforms to DALI standard of 9.522.5 vdc and 250mA max. CoreNet RT03 bus power supply required for network configuration. XDCP - Starfield Extended DALI Control Protocol ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Warranty: Limited 3-year warranty Page 8 105.7.2 Configuration 1. 2. TR218 controllers are shipped to Table 1 - Factory Default Settings begin working right 4 Button 2 Button out of the box with Setting default settings Config Template 0 10 listed in Table 1. Group Broadcast Broadcast Once installed and On Level 50% 50% tested, the controlIndicator Light Slow Flash Slow Flash ler may then be Night Light Off Off reconfigured directly via the user buttons or indirectly via the DALI network and the CoreNet controller configuration utility. Available Settings: Configuration templates per Table 2. DALI Group Addresses - Broadcast and DALI groups 0-15. A. Front of Controller Configuration Procedure 1. Stop! Before reconfiguring the controller, first verify that all functions are working properly with the factory default settings. 2. Choose a Button Template: a. Template - Retain default and skip next three steps or choose a Template from Table 2. b. Program Mode - Press and hold buttons 1 & 4 for 15 seconds until the indicator light turns on. c. Select a Template - Putting the controller into program mode has selected template 0. Tap any button to advance to a different template. Example: Tap three times to choose Template 3 and six times to choose Template 6. d. Return to Operation Mode - After choosing a template, allow the controller to sit for 15 seconds until indicator light turns off. 3. Set the Group Address - After choosing a button template or retaining the default template, set the TR218 to a group address corresponding to the group of DALI devices to be controlled. a. Program Mode - Press and hold buttons 1 & 2 for 15 seconds until the green indicator light turns on. b. Select an Address - Putting the controller into program mode Table 2 - Button Configuration Templates (1) Tmp Application B1 B2 B3 B4 Notes 0 General Use Entry 3M R L Off 2 3 Small Conf Rm Entry 3S1 R L Off 3 4 Small Conf Rm Entry 3S4 R L Off 3 5 4 Scene Presets S1 S2 S3 S4 4 6 4 Scene Presets S5 S6 S7 S8 4 7 General Use Entry Mid Ron L Off 10 Two Button Entry On/Off R/L - - 5 Table 2 Notes 1) Configuration templates in this table can be field selected from the front of the controller using control buttons or via the DALI network using CoreNet controller configuration utility. 2) Four button default template - General purpose entry control. 3) Full function control for smaller rooms needing scenes and entry control in one. 4) Scene control for larger rooms typically used together with an additional scene dimmer set to Tmp 0. May be ordered with enunciator lights to keep track of selected scene. 5) Two button controllers do not support configuration template selection. sets the controller group address to broadcast. Tap any button to advance to another group address starting with group 0. Example: To choose Group 0 - tap once. To choose Group 5 tap six taps times all the way up to Group 15 with sixteen taps. c. Return to Operation Mode - Allow the TR218 to sit for 15 seconds until the green indicator light turns off. 4. Group Test - After resetting the group, test to verify that the group setting is correct. 5. Troubleshooting a. Scenes - Remember that the DALI default for scenes is Mask so there will be no response until scene values are set in the DALI devices. b. Lights not Responding - If the lights are not responding and the DALI group address and scene values have been (Continued on page 10) Connection Diagram DALI network bus. Class 1 or 2 wiring per NEC article 300 requirements. DALI Class 2 Power Supply CoreNet RT03 or equivalent DALI Ballasts TR218 LS230 Sensor TR51 Dimmers & other CoreNet DALI Controllers Wiring Notes 1) TR218 controllers are connected with two DALI wires that both power the controller and provide network communication. 2) DALI network buses are two wire, non-polarized, free-topology parallel circuits rated to be pulled directly with lighting power wires or independently using Class 2 cable. 3) See CoreNet Design & Installation Guidelines, for wiring & installation recommendations. TR218 Order Number TR218 _ - Button Enunciators (1) E Blank for none 4 W W Buttons Case Color Button Color 2 4 W B G I W B G I Colors (2) White Black Gray Ivory Order Notes 1) Enunciation lights available for 4 button scene controllers only - config templates 4,5. 2) White/White is standard. Table 1 Column Header Abbreviations: Tmp Function Template code. B1-B4 Buttons 1-4 with B1 located closest to green indicator light. Page 9 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 (Continued from page 9) checked then reset the controller address to broadcast and test. If that works then set the controller to the correct address and test again. c. Counting - Be careful about setting the group address as group numbering follows digital conventions where the first group is zero instead of one. D. Dimming Operation B. Button Functions (3M) Mid/Max/Min Cycle - Our most The 50% “On” Level popular “on” function. Turns lights In a most well-designed on at 50% for excellent energy savings and most user needs while lighting systems 100% is too bright for most providing rapid access to max and users. Instead, turning min levels with successive button lights on at 50% protaps. vides greater comfort (On/Off) - Each tap alternates befor the majority of users tween on at mid and off. along with significantly (Off) - Turns lights off with user lower energy use. defined fade time. (R) - Raise - Tap to increment. Press and hold to scroll up. (L) - Lower - Tap to increment. Press and hold to scroll down. (R/L) - Raise/Lower - Each press and hold alternates between raise and lower scroll functions. (Ron) - Same as R function but turns lights on if they are off. (3S1) - Scene Cycle - Cycles scenes between 1-3 (3S4) - Scene Cycle - Cycles scenes between 4-6. (Sx) - Goto scene indicated by “x” value. D. DALI Dimming Curve - All dimming adjustments follow the DALI logarithmic dimming curve so that low level adjustments are much finer than high. DALI Ballast Settings: Fade Time - Time to change to a new level or scene. Fade Rate - Scrolling fade rate. Min-Max Range - Allowed “On” Level Adjustment light level range. For special applications Relative Dimming - Scrolling changes the dimming level rela- where an “on” level other than 50% is required, tive to the existing light level in CoreNet provides a coneach individual ballast. figuration utility within the Admin Lite software that Controller Operation allows Administrators to Controller Indicator Light set the “on” level to any Green LED indicates current level between 30-70%. controller state or event. Night Light - Indicator light turns on when lights are off. Enunciator Lights - Optional red or amber LEDs next to buttons used to indicated selected scene. Mid - 50% light level default level. D. Network Configuration D. Button Operation Scroll - Press and hold to raise or lower light level. Level adjustments are made relative to current setting. Suggested for both general applications and use with scenes. Scroll rate determined by DALI ballast fade rate setting. Alternate Action - Alternates between defined functions with each button tap. Cycle - Cycles to next function with each button tap in a continuous loop. On and Off - On and off operations are done with user defined fade time setting. Group - DALI group number assigned to the controller. Group numbers are equivalent to traditional architectural control zones. Multi-Station Operation - Any number of controllers may be assigned to the same group to create true multi-station peer- CA Title 24 Section 119 Certifications 1. Energy - On function meets California Title 24 2008 Energy Code Sections 131(b) mandatory Multi-Level Lighting Control and 146(a)4(D) optional Energy Design Credits when used with dimming ballasts. 2. Energy - On function meets California Title 24 2012 Energy Code (proposed) Section 119(e) mandatory requirement for Multi-Level Occupancy Sensor when used in conjunction with the CoreNet LS230 sensor and dimming ballasts. 3. Scene Restrictions- All scene calls are assumed to be “on” commands as “off” scene commands cannot be definitively interpreted by the controller to keep track of room state. 4. Compatibility - The TR218 is compatible with DALI compliant ballasts and other DALI devices to include CoreNet TR51 dimmers, TR602 0-10v ballast drivers, and TR401 and LS230 relay drivers. CA Title 24 Compliance Notes: 1. 2. Category Description Dim Relay Notes DIM Dimmers NA NA 1 MOS Vacancy Sensor X No 2,3,4 MLO Multi-level Occupancy Sensor X No 2,3,4 3. 4. ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com General - In addition to front-of-controller button configuration, the CoreNet TR218 controller can also be configured over DALI networks powered by an RT03 bus supply. Configuration Software - Network configuration requires the CoreNet controller configuration utility provided with the CoreNet Admin Lite software. D. Configuration Notes Energy Code Compliance The TR218 has been designed to be in compliance with or to support interior lighting control requirements of the three most widely accepted USA energy codes: 2009 IECC Section 505, Standard 90.2-07 Section 9.1.1, and California’s Title 24 Sections 119, 131, 146. to-peer operation. Button Coordination - Button functions are coordinated with the room on/off state, between multiple control stations, and with remote commands when used in accordance with design guidelines. DIM Category - Not applicable to the TR218 or other CoreNet controllers as it refers to power control devices such as DALI ballasts and the TR51 dimmer. MOS and MLO Certification - Both are system certifications for use in conjunction with CoreNet LS230 motion sensors. Scene Restrictions- All scene calls are assumed to be “on” commands as scene commands cannot be definitively interpreted by the controller. Multi-level Relay Control - See the TR402 for multi-level relay control. Page 10 105.7.2 Accessories Gateways Line Voltage Dimmer Relays Networking Mounting Plates Software Page 11 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 TR217 - DI and AI Gateway Made in USA Energy Management CA Title 24 Compliant Same functionality as TR218 but with DI and AI terminals. Typically used as a gateway to external motion and light sensors and to other BAS sysKEY FEATURES Digital Input (DI) for use with external motion sensors and dry contact input from other building control systems. Analog Input (AI) for use with external light sensors. Configurable directly with user buttons or indirectly over the DALI network. Peer to Peer control with unlimited multi-station operation. Compatible and coordinated with CoreNet computer controls. Mounts in standard NEMA switch boxes with standard Decora style coverplates or in 11B boxes on the MP2X mounting plate. Directly compatible with DALI standard ballasts. Wires directly to the DALI network bus. Green controller indicator light and optional enunciator lights provide intuitive user feedback. SPECIFICATIONS Electrical UL Listed Class 2 device. May not be installed in same electrical box with electrical power wires. DALI bus power supply must be CoreNet RT03 or equivalent Class 2 power supply that conforms to DALI standard of 9.522.5 vdc and 250mA max. CoreNet RT03 bus power supply required for network programming. Digital input terminals 3-4 are optically isolated. Accessory power supply: +10vdc,15mA max. DALI bus load: 6mA base controller power 3mA for optional enunciation lights 3mA for optional night light External sensor power—see sensor specifications ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com TR217 - Four button wall mounted. Cover plate not included. TR217 - No button model mounted on the MP2X inside a NEMA 11B electrical box. Physical NEMA Decora form factor. Compatible with Decora single and multigang coverplates and with Lutron CW-1 screwless coverplates. Terminals and Wire: 5mm screw clamp terminals Copper conductors only Tighten to 4.5 in-lbs torque Wire size 12-22 AWG—Wire size larger than 18 AWG must be stranded. Caution: connecting solid wire larger than 18AWG may damage controller, make alignment difficult, and void the warranty. Housing & Button Cap Material: 94v0 UL listed fire rated ABS/ PC alloy plastic. Available Colors: NEMA WD1 White, Black, Gray, Ivory. Environmental Operating Temperature Range: 0 to 55°C, 32 to 131°F Storage Temperature Range: -10 to 85°C,14 to 185°F Relative Humidity: 20-90% non-condensing Communication & Transmission Protocol DALI - IEC standard 60929 Ed. 2/CDV Annex E.4 and G XDCP - Starfield Extended DALI Control Protocol Warranty: Limited 3-year warranty Configuration Instructions: Page 12 See TR218 data sheet 105.7.2 CONFIGURATION OPTIONS Occupancy & DI Functions (CoreNet compliant motion sensor not Table 1 - Program Templates (1) Tmp Application B1 B2 B3 B4 E O D Notes 0 Private Off/Class Entry (default) 3M R 1 White Board/Teacher 3M R L Off N V Lm 2 L 3S1 Y V Lm 2 White Board/Teacher 3M 3 R L 3S4 Y V Lm 3 Small Conf Rm Entry 3 3M 3S1 R/L Off Y V Lm 4 4 Small Conf Rm Entry 3M 3S4 R/L Off Y V Lm 4 5 4 Scene Presets S1 S2 S3 S4 Y Oc Lm 5,8 6 4 Scene Presets S5 S6 S7 S8 Y Oc Lm 5,8 7 Alternate Off/Class Mid Ron Loff Off N V Lm 6 8 Toilet, Corridor, Public 3M R L Off N Oc SP 7 9 Corridor & Open Space 3M R L Off N R SP 7 10 Discontinued included.) All CoreNet occupancy functions include a 10 minute warning period during which light level fades to Min. Motion during this period restores lights to previous level. Vacancy (V) - Manual-on/Auto-off. Consistent and intuitive operation plus highest energy rating for enclosed spaces. CA required for residential applications and recommended for commercial. Use with 3M or Lx 70% or less button functions to qualify for CA power adjustment factor per Title 24 Section 146A(a)4D. Occupancy (Oc) - Auto-on/Auto-off. Traditional “occupancy” function. Recommended for use in areas without manual controllers. Restore (R) - Indefinite warning period at minimum level. Use for private offices, hallways, and other spaces where low-level light is desired or required during unoccupied periods. Timeout Switch (OSw) - Same functionality as Oc but initiated manually for all Button functions except scenes. Timeout period 1-90 minutes. DI Contact Closure Inputs 11 3M Table 2 Notes 1) Program numbers in this table can be field selected using control buttons. 2) General purpose entry control. 3) Front of room control used in conjunction with entry control. 4) Full function control for smaller rooms needing scenes and entry control in one. 5) Greater control for larger rooms. Use in conjunction with Prog 0 entry control. 6) Alternate entry control with on/off R/L functions. 7) Automatic control for public spaces. often used with blank face. 8) At entry doors, must be used in conjunction with entry door controller to provide absolute on as required to meet life safety codes. Daylight Functions (CoreNet compliant light sensor not included.) Dimming Functions Dimming Curve - All dimming adjustments follow the DALI logarithmic dimming curve whereby adjustments at low light levels are much finer than bright levels. Scroll - Tap to increment. Press and hold to raise or lower light level. Level adjustments are made relative to current setting. Suggested for both general applications and especially for use with scenes. Fade Time - DALI Ballast setting of adjustment period between settings. Fade Rate - DALI Ballast setting of increments per second used with scroll. TR217 ORDER NUMBER TR217 _ - Button Enunciators E (1) Blank for none Buttons 0 (2) 2 (3) 4 (4) 4 W Lumestat tm (Lm) - Maintains user light level. Use for classrooms, offices, conference rooms with manual controls with closed loop daylighting and one light sensor per daylight zone. Setpoint (SP)- Conventional setpoint control maintains constant setpoint. Use for open or public spaces without manual dimming control. Daylight Max (DM) - Limits total light level to an administrative max. Does not maintain a setpoint. Use for conference and class rooms with open loop daylighting and manual control. General OPERATION & CONFIG NOTES Occupied/Unoccupied State (DI1) - Closing Action = goto scene13 (unoccupied), Opening Action = goto scene 14 (occupied). Emergency State (DI2) - Closing Action = save current light levels to scene 11 then goto scene 12 (emergency), Opening Action = Restore scene 11. Min-Max Range - All light level adjustments are limited to the Min-Max range whereby light level cannot be set higher than Max or lower than Min. Controller Indicator Light - Green LED indicates current controller state or event. Enunciator Lights - Red or amber LEDs next to buttons indicate scene, button, or other states as labeled. Mid - 50% light level. Max - DALI Ballast setting. 100% or lower light level set by user. Min - DALI Ballast setting. Ballast minimum or higher level set by user. Alternate Action - Release to change to alternate function. Cycle - Release to cycle to next function or repeat cycle. Group - Control zone converted to a DALI group number between 0-15. TR217 WIRING DIAGRAM W Case Color Button Color W B G I W (5) B G I DALI network bus. Class 1 or 2 wiring per NEC article 300 requirements. To additional DALI compliant ballasts and controllers DALI Class 2 Power Supply CoreNet RT03 or equivalent DA 1 DA 2 Order Notes 1) Enunciation lights available for 4 button scene controllers only - config templates 4,5. 2) Controllers without buttons are typically used as plenum mounted gateways mounted on the MP2X cover plate. Provided as four button controller without button caps and config template 0. Buttons are accessible through access holes in the MP2X cover plate to be used for configuration and testing. 3) Two button controller provided with config template 10 suitable for both DALI dimming and relay control. 4) Four button control is provided with config template 0. 5) White/White is standard. Page 13 + DI 3 Com DI 4 + AI 5 Com AI 6 +10vdc 7 Spare 8 DALI Ballast DALI Occupancy Sensor Photo Sensor DALI signal com signal com pwr pwr TR217 Class 2 Controller Mounting box − DALI wiring, Class 2 devices, and Class 2 wiring only. See CoreNet Design & Installation Guidelines, for additional wiring recommendations. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.6 TR602 - DALI to 0-10V Gateway Made in USA Energy Management Rugged Decora style controller mounts in a standard NEMA switch box or on the CoreNet MP2X mounting plate. Provides full-function DALI operation to include grouping and scenes for a single lighting zone with 010v dimming ballasts. Also includes a optional connection for a CoreNet PPUV 20A relay to provide full off required for some 0-10v ballasts. FEATURES Interface with 0-10V controlled components Peer to Peer control with unlimited multi-station operation. Compatible and coordinated with CoreNet computer controls. Mounts in standard NEMA switch boxes with standard Decora style coverplates or in 11B boxes on the MP2X mounting plate. Directly compatible with DALI standard ballasts. Wires directly to the DALI network bus. Green controller indicator light and optional enunciator lights provide intuitive user feedback. Directly connect motion and light sensors without external power packs. SPECIFICATIONS Electrical UL Listed Class 2 device. May not be installed in same electrical box with electrical power wires. DALI bus power supply must be CoreNet RT03 or equivalent Class 2 power supply that conforms to DALI standard of 9.5-22.5 vdc and 250mA max. CoreNet RT03 bus power supply required for network programming. DO - Digital output terminals 3-4 are optically isolated and rated to switch up to four CoreNet PPUV relays connected in parallel. Accessory power supply: +10vdc,15mA max. 0-10vdc sink capacity: 20mA DALI bus load: 7.5 mA base controller power with status indicator light. Copper conductors only Tighten to 4.5 in-lbs torque Wire size 12-22 AWG—Wire size larger than 18 AWG must be stranded. Caution: connecting solid wire larger than 18AWG may damage controller, make alignment difficult, and void the warranty. Housing & Button Cap Material: 94v0 UL listed fire rated ABS/PC alloy plastic. Available Colors: NEMA WD1 White, Black, Gray, Ivory. Environmental Operating Temperature Range: 0 to 55°C, 32 to 131°F Storage Temperature Range: -10 to 85°C,14 to 185°F Relative Humidity: 20-90% non-condensing Communication & Transmission Protocol DALI - IEC standard 60929 Ed. 2/CDV XDCP - Starfield Extended DALI Control Protocol Warranty: Limited 3-year warranty N Line RT03 DALI Bus Supply 0-10v Dimming Ballast DA 1 DA 2 +DO 3 DO Comm 4 Physical NEMA Decora form factor. Compatible with Decora single and multigang coverplates, Lutron CW-1 screwless coverplates, and CoreNet MP2X mounting plate. Terminals and Wire: +AO 5 AO Com 6 +10V Pwr 7 Spare 8 TR602 WIRING DIAGRAM 5mm screw clamp terminals ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com PPUV 20 Amp Relay Page 14 105.7.2 TR51-Dual Channel for Incandescent and LED Dimmer Made in USA Energy Management The TR51 is a 120volt, 600 VA, two channel incandescent dimmer with full function DALI interfaces for each channel. Use for conference rooms, retail, restaurants, and similar applications to control incandescents by themselves or in conjunction with dimming or relay controlled fluorescents. The TR51 mounts on a standard NEMA 4 -11/16” electrical box located in an electrical closet or in the ceiling adjacent to lighting. Interfaces with standard DALI compliant dimmers, scene, on/off, and other controls. FEATURES Physical Supports applicable DALI functions including addressing, groups, scenes, and query Independent channels with separate DALI address and functions Compatible with standard DALI controls including dimmers, on/off, and scene controls Mounts on conventional 4-11/16” electrical box 600 watts per channel Compatible with DALI dimmers, on/off, an scene controls LED indicator lights for power, DALI messaging, and fuse fail alarm. Remote query, control, and configuration SPECIFICATIONS Environmental Input Power: 120v Internal fuses: 5amp fast blow each channel Replacement fuse: Starfield FFB5 Power dissipation : 5 watts per channel max Electrical - DALI Input voltage - 12-22.5 vdc Input current - 2mA UL listed for Class 1 and Class 2 DALI network wring Compliant with IEC international DALI standard 60929 Page 15 Operating Temperature Range: 0 to 40°C Storage Temperature Range: -10 to +50°C Relative Humidity: 20-90% non-condensing Factory Presets Electrical - Power Nominal Size: 4-11/16” x 1.5 inches 5mm screw clamp terminals are rated for use with 18 AWG solid or 18-14 AWG stranded copper wire. Caution - Use of large gauge solid wire may damage terminals and make installation difficult. Housing: zinc plated steel Power Failure Reset - 254 (full bright) System Power Failure - 254 (full bright) Scene Settings - 255 (no change) Groups - Unassigned Warranty: Limited 2-year warranty ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.6 TR400 - DALI Digital Output & Relay Controllers Made in USA Energy Management The TR400 family of controllers with one to four digital outputs to driver CoreNet PPUV relays or to interface to other equipment and systems. Each channel is electrically isolated to 2500v, can be configured for NO, NC, or electrically latched operation, and can be given a unique DALI address with full DALI functionality to include scenes and group assignments. FEATURES Full-function DALI attributes for each channel includ- ing a unique DALI address and up to 16 scene and group assignments. Decora style housing mounts in a standard NEMA switch or outlet box and uses standard Decora switch plates. DALI network wiring is polarity-independent, freetopology, low-voltage, and low-power, May be run as NEC Class 1 or 2 inside or outside of the lighting power conduit as allowed by local jurisdictions. The TR401 is assignable to any one of 16 groups from the front-side of the control without tools or special equipment. LED indicator is used for initial configuration identification and flashes each time buttons are pressed. TR404 enunciation lights by each button turn on when relay is closed. SPECIFICATIONS Electrical UL Listed Class 2 device for use with Class 1 and Class 2 DALI bus wiring DALI Input voltage - 12 -22.5 vdc Digital Output (DO) transistor: Voltage isolation - 2500v Switching capacity - 12mA Switching voltage - 5-24vdc DALI continuous current draw TR401,2,3 - 5.0 mA TR404 with enunciation - 8.5 mA Optional night light add - 3.0 mA Physical NEMA Decora form factor 5mm screw clamp terminals are rated for use with 22- 18 AWG solid or 22-16 AWG stranded copper wire. Use of large gauge solid wire may damage terminals and make installation difficult. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com TR401 with blank face housing TR404 with enunciator lights Housing & Button Cap Material: 94v0 UL listed fire rated ABS/PC alloy plastic. Available Colors: NEMA WD1 White, Black, Gray, Ivory. Environmental Operating Temperature Range: 0 to +55°C Storage Temperature Range: -10 to +85°C Relative Humidity: 20-90% non-condensing DALI Command Response For scene and level commands use values: 254 = on, 0 = off, 255 (mask) = no change. TR401 latch configuration options: Set SysFail value - 0=NO, 1-254=NC, 255=electrically latched. Warranty: Limited 3 Year on defective materials and workmanship ORDER NUMBER TR400 - 4 W W Model Buttons Case Color Button Color 401 - Single Channel 402 - Bi-Level 403 - Curtain 404 - Four *Channel *** 0 (All) ** 2 (401,402,403) 4 (404) W* B G I W* B G I * Stock colors. ** Blank housing for plenums mounts on MP2X mounting plate. *** Standard with enunciation lights and electrical latching. Page 16 105.7.2 PPUV - 100-277v Universal Voltage 20A Lighting Relay The PPUV is a self powered SPST, NO (Type A) lighting relay that can be directly connected to CoreNet sensors and controllers. It features Zero Arc Point Switching for extended contact life and universal voltage input for 120-277 applications. The PPUV is plenum rated and easily mounts either inside or outside a standard electrical boxes or inside a fluorescent ballast cavity. When used with the LS230 or TR401 relay drivers it can be configured for NC, NO, or electrically latched operation. When used with the TR404 inside PPH relay panels it is electrically latched and provided with on/off enunciation lights. FEATURES PPUV - 20A 100-277v lighting relay. Physical Universal voltage (100-277 VAC; 50/60Hz) 20A lighting loads Size: 3.69”x2.33”x1.36” Zero arc point switching for maximum contact life. Mounts through a 1/2” KO with included 1/2” lock nut. Plenum rated Housing Material: High impact, plenum rated 94-5V plastic UL and cUL listed Color: Black 5-year warranty SPECIFICATIONS Environmental Indoor use only Electrical Operating temperature: 32-104ºF (0-40ºC) UL and cUL listed Relative humidity (non-condensing): 0-95% 100-277 VAC; 50/60Hz Relay contact ratings: Warranty: 5 Year limited warranty on defective materi- 20A: 120VAC Incandescent als and workmanship excludes consequential damages. 20A: 120 or 277 VAC ballasts 1HP: 120 or 277 VAC motor load Sustained switching current - 0.6 mA Page 17 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 RPH - DALI Relay Panels Made in USA 508A CoreNet DALI Relay Panels are a versatile family of networked relay panels that mount on standard Hoffman electrical pull-boxes and swing-out for easy field access and relay replacement. Each relay has a standard DALI address and accepts all relevant DALI settings including groups and scene presets. Relays can be controlled locally with enunciated on/off buttons and remotely with two and four button controllers and the CoreNet Scheduler. FEATURES Relays are standard CoreNet PPUV 20A lighting relays with zero crossing switching and universal voltage for 100-277v lighting loads. (See PPUV data sheet) Zero crossing point switching minimizes relay-contact wear from arching and high inrush loads. Relay are replaceable with standard CoreNet PPUV relays and the four channel relay controller is replaceable with the standard CoreNet TR404 controller. Relays can be operated locally or remotely and support all relevant DALI settings including scenes and groups. Enunciation light by each manual on/off button provides visual confirmation of current state. Integrates with CoreNet user controls, sensors, and distributed relays. Mounts on a standard Hoffman pull-box. Expandable and scalable. Electrically latched operation returns relays to their previous state when DALI control power is cycled. RPH DALI Compliant Relay Panel - Provides manual on/off enunciated operation and mounts on standard Hoffman pull box enclosure. (8 relay panel show. Enclosure not included). Enclosure Hoffman pull box (not provided). See Hoffman Pull Box Table for sizing. Physical Size: See Hoffman Pull Box Table Material: 16 gauge cold rolled steel Color: Black Finish: Power coat Environmental Indoor use only Operating Temperature Range: 0 to +55°C Storage Temperature Range: -10 to +85°C Relative Humidity: 20-90% non-condensing DALI Command Response Scene and level command values: SPECIFICATIONS Electrical UL 508A certification DALI Input voltage - 12 -22.5 vdc DALI Input current 4 channel 8 channel 12 channel 1-254 0 255 Warranty: Limited 3 years on defective materials and workmanship. 9 mA 17 mA 26 mA Relays CoreNet PPUV ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com on off (mask) = no change Page 18 105.7.2 RELAY SYSTEM SCHEMATIC Relay Configuration - relays in different panels connected to the same DALI network bus may configured to operate together by assigning them to the same DALI group. Lighting Power RPH relay panels. Add additional panels as required to provide the total number of required relays. Conduit - Lighting power conduit with combined power and DALI network wires. To additional equipment Class 2 conversion box Electrical box– standard NEMA electrical box. RT03 Bus Supply Class 2, 2-wire cable to sensors and user controls. Lighting Trunk Network TR218-2 User Control TR218-2 User Control LS230 Combo Sensor HOFFMAN* PULL BOX MODEL RPH Model Relays Model Number (Size in inches) RPH-4 4 ASE12x12x4 RPH-8 8 ASE16x12x4 RPH-12 12 ASE24x12x4 *Pull box not included. Hoffman is a trade name of Pentair Technical Products, www.hoffmanonline.com Page 19 RPH ORDER NUMBER RPH - X Model RPH Relays 4 8 12 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 FIELD WIRING 4 1 2 3 120-277v N Red Red Blk Wht PS LD Parts List 1 Electrical panel power bus 2 Electrical panel neutral bar 3 CoreNet PPUV Relay 4 CoreNet relay panel enclosure LD PS Symbols Legend PS IDC tapping connector Terminal block or butt splice as necessary to convert to stranded wire and change wire gauge. Wire nut or equivalent connector that can be easily removed and reinstalled if relay replacement is required. LD Relay power supply. Switched load. Field wiring per project and local jurisdiction requirements. 20A Circuit breaker. Relay panel wiring. Stranded copper with insulation to match field wiring. #14 unless stated or required otherwise. Relay. Relay connected wiring. FIELD LABELING Label Legend Address Zone/Circuit No. Address - DADALI LI address Address address Zone/Circuit - Control zone and/or Control zone name or room switched circuit. number and/or switch circuit No. - Relay nupanel mber and number Panel - Relay panel number No. Bus Suppl y - Relay DALInumber bus supply equipment nu mber and/or IP address. Panel Relay panel number DALI Bus - DA LI bus (0 or 1) feeding Bus Supply DALI bus supply equipment this panel. number and/or IP address. Zone/Circuit DALI Bus Panel Bus Supply DALI Bus ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page 20 DALI bus number (0 or 1) 105.7.2 RT03 - Dual Bus DALI Power Supply. Router, and TCP/IPDALI Gateway Made in USA Energy Management The RT03 bridges the gap between the fragile world of high-speed TCP/ IP networks and the noisy, rough and tumble world of devicelevel networks. It has two full power DALI networks (commonly called buses and sometime loops) that can operate independently or be bridged together to form extended DALI groups. Individual routers can also be stand alone or networked together to create interactive whole-buildings control systems. 120 N 277 Primary Pwr Class 1 DALI Loop 1 Loop 2 Bottom Plan View Ethernet Class 2 DALI Loop 1 Loop 2 Pwr Bus Fail 1 Bus Fail 2 Mounts on 4-11/16” electrical box 4-11/16 Sq Electrical Box (not included) Side Elevation The RT03 mounts directly on NEMA 4-11/16 deep electrical box. FEATURES Two fully rated DALI control buses. Suitable for use with both Class 1 and Class 2 DALI circuits. 120/277 dual voltage primary. 10basT Ethernet port. LED indicator lights for Ethernet (link, xmit, rec), power-on, and DALI bus failure. Mounts on standard NEMA 4-11/16 sq electrical box. Page 21 Router level command set for high speed, parallel processing and with minimum network traffic. CoreNet’s Admin Lite lighting management software included. Up to 128 addressed devices per extended DALI group. ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 SPECIFICATIONS Electrical Primary - 120/277vac, 12VA Bus Ratings - 16vdc nominal, 190mA Connected Load 250mA Charging UL listed for Class 1 and Class 2 DALI bus wiring. Terminals - 5mm screw clamp terminal blocks rated for 18 AWG solid or 16-18 AWG stranded copper wire. Grounded secondary. Material - Cover 18ga steel, Base 16ga steel. Finish - Black zinc platting and textured black metal power coat. Mount - 4-11/16 sq electrical box. Networking 10basT Ethernet One IP address per router 2 DALI buses may be logically linked by group to allow up to 128 addressed devices per group. Housing Environmental Operating Temperature Range: 0 to +55°C Rating - NEMA 1 for indoor use only Nominal Size - 4-11/16 sq x 2 inches Relative Humidity: 20-90% non-condensing Individual User Workstations Building System Operator Workstations Additional Routers as Needed Storage Temperature Range: -10 to +85°C Lighting System Computer Ethernet 10basT network cable. Ethernet Hub 277/120v Ethernet Hub 277/120v RT03 Router 1 DALI Loop 1 RT03 Router 2 DALI Loop 2 DALI Loop 1 DALI Loop 2 WIRING LEGEND System Wiring Diagram - Connect RT03 routers as needed to create control networks of any size. Each router serves as both DALI power supply and an Ethernet to DALI gateway. 120/277v Device Power Ethernet - Class 2 DALI Local Net - Class 1 or 2 ORDERING: RT03 - 120/277 volt dual bus power supply and router. Includes DALInet™ System Management software. ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page 22 105.7.2 Network Accessories - Serv1,2,3 - System Controller & Server Industrial grade, 2U rack mounted PC computer with keyboard and monitor ports but intended for use as a “blind” server. Comes complete with rack mounting hardware and MS XP Pro operating system, and two NIC cards for connecting to the lighting control network and the Internet or building Intranet. Serv1,Serv2,Serv3 - Industrial grade, rack mounted, 2U lighting servers with three levels of functionality. DESCRIPTION Rack mount Computer - 19" 2U Industrial Rack Mount Case, Intel Core i3, i5 or i7 CPU, Intel Motherboard, H55 Express Chipset, 1GB DDR3 1333MHz RAM, SATA DVDROM, GbE LAN, 250GB SATA HDD, Onboard Audio, 12 x USB 2.0, 300W P/S Type: 19" 2U Rack Mount Case Construction: Heavy-duty cold-rolled steel Drive Capacity: Exposed 1 x 5.25" and 1 x 3.5" drives Cooling: 1 8cm ball-bearing fan Front Panel Indicators: 1 x pwr on/off, 1 x HDD Front Panel Controls: 1 x pwr on/off, 1 x system reset Front Panel Connectors: 2 x USB Dimensions: 19" W x 19.6" L x 3.5" H 300W 115/230V ATX auto switching power supply Maximum Expansion Card Length: 9.5" Intel Motherboard: Features H55 Express Chipset - Intel® Core™ i7, Intel® Core™ i5, Intel® Core™ i3, and Intel® Pentium® Socket 1156 processor support. Processor: Includes Intel's new 32nm 2.8GHz Intel Pentium Dual Core Socket 1156 G6950 Processor (Upgradeable to Core i3, i5 and i7 Processors) Graphics Controller Built Into the Processor. Memory: Includes 1GB DDR3 1333MHz System Memory - (Upgradeable to 16GB) - Memory Con SPECIFICATIONS Hard Drive: 250GB Western Digital 7200RPM SATA HDD. LAN: 2 Onboard Gigabit LAN NIC cards Video: VGA, DVI-D and HDMI connectors for dual independent display for processors with Intel® Graphics Technology (included on all processors except the i7 Processor, for graphics support using the i7 processor, please add video card and riser) Audio: 8-channel (5.1+ 2 independent multistreaming) audio subsystem with three USB: Support for USB 2.0 devices LAN Support: 10/100 Mbits/sec LAN subsystem using the Intel® 82562GX/82562 PLC device Peripheral Interfaces: Eight USB 2.0 ports One serial port One parallel port Four Serial ATA interfaces One parallel ATA IDE interface with UDMA 33, ATA-66/100 support One diskette drive interface PS/2 keyboard and mouse ports Expansion Capabilities: 3 Expansion Slots: SOFTWARE OS: MS Windows XP Pro Support: MS Access and Excel Other: Additional CoreNet software and utilities as required. troller Built Into the Processor. Page 23 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 Network Accessories - ES16,24 - Ethernet Switch Industrial grade 16 and 24 port rack mounted Ethernet switch. Intended for use as the Main Switch typically mounted adjacent to Lighting System Controller/ Server. ES16,24 -16 or 24 port industrial grade rack or backboard mounted 1U Ethernet switch. Specifications • Network Ports ––JGS516: 16 10/100/1000 Mbps twisted-pair RJ-45 ports ––JGS524: 24 10/100/1000 Mbps twisted-pair RJ-45 ports • Performance –– Switching bandwidth: JGS516: 32 Gbps JGS524: 48 Gbps –– Forward rate (1000 Mbps port): 1,480,000 packets per sec –– Forward rate (100 Mbps port): 148,000 packets per sec –– Forward rate (10 Mbps port): 14,800 packets per sec –– Jumbo frames latency (1000 to 1000 Mbps): 20 μs max –– Packet buffer memory: 2 Mb –– MAC address database: 8,000 –– Mean time between failures (MTBF): JGS516: 309,000 hours (~ 35 years) JGS524: 230,000 hours (~ 26 years –– Acoustic noise: 40 dB • Power Consumption –– 100-240V; 50-60 Hz; plug is localized to country of sale ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com –– JGS524: 16W max –– JGS516: 11W max • Standards Compliance –– IEEE 802.3i 10BASE-T Ethernet –– IEEE 802.3u 100BASE-TX Fast Ethernet –– IEEE 802.3ab 1000BASE-T Gigabit Ethernet –– IEEE 802.3x flow control • Status LEDs –– Unit: power –– Per network port: Link, activity, speed • Physical Specifications ––Dimensions (h x w x d): 43 x 330x 207 mm (1.7 x 13 x 8.2 in) ––Weight: JGS516: 1.62 kg (3.57 lb) JGS524: 1.72 kg (3.79 lb) • Environmental Specifications –– Operating temperature: 0° to 50° C (32° to 122° F) –– Operating humidity: 90% maximum relative humidity, non-condensing –– Storage temperature: -20° to 70° C (-4° to 158o F) –– Storage humidity: 10 to 95% relative humidity • Electromagnetic Compliance –– CE mark, commercial –– FCC Part 15 Class A –– VCCI Class A Page 24 105.7.2 Mounting Plates MP2X - TR Controller Mounting Plated Mounting plate for TR zero button controllers attaches to standard NEMA 11B deep electrical boxes. Holds 1 or 2 controllers and can be plenum mounted. Cover has holes for indicator light and four 1/32” holes for accessing circuit board mounted switches to allow field testing and configuration. MP2H - Bus Supply Mounting Plate - Designed to mount inside a Hoffman 24x24” A24N24ALP enclosure to create a field assembled bus supply cabinet with capacity for up to 6 RT03 bus supplies and an optional 8 port Ethernet switch. Pre-punched Mounting Plate - MP2X shown with single TR controller attached. Reduce Network Cables - Use this cabinet mounted switch and universal power supply to connect cabinets to the main Ethernet switch with a single cable. ESD8- Industrial grade 8 port DIN rail mounted Ethernet switch PSD30- 30W, 100-277V, DIN rail mounted universal power supply MP2H - Mounting plate for up to 6 RT03 Bus Supplies. Designed to be mounted inside a Hoffman 24x24” hinged cover NEMA 1 enclosure part number A24N24ALP. Comes complete step-by-step instructions, recommended BOM, and assembly pictures. MPCV - (Note Shown) - Plate for covering unused RTO3 openings. Assembled Bus Supply Cabinet showing contractor supplied enclosure, mounting hardware, terminal blocks, and DIN rail. Page 25 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.6 Software - Configuration, Maintenance, Management DALI COMMISSIONER Add devices to the control bus—use this feature when adding a DALI actuation device to an already existing group of devices, or when replacing a ballast. Initialize all devices—This feature is used when first addressing an entire bus. Arbitrate duplicate addresses—Will rectify a situation where 2 devices have the same address. Find Active devices— Displays all of the address currently visible on a bus. Remove short address—Removes the short address from a DALI device Set short address— Used to change the address of a DALI actuation device. ADMIN LITE - Control, Configure and Query software to Startup and Manage Starfield Control’s line of DALI control devices and standard DALI ballasts. (requires RT03 Dual Bus Power supply and Admin Lite Capabilities Direct Connect or connect through an Ethernet network Database Architecture Build sets of devices for fast, intuitive startup and control Ballast replacement settings Daylighting setup Controller property query Real-time batch queries Runs on any PC or Laptop using Windows XP Pro or Home editions ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page 26 105.7.2 DATABASE BUILDING Select individual Routers by IP Address and by bus (Requires RT03 Dual Bus Power Supply/ Network Router) note: networking of RT03 Routers not required for local control. Automatically draws in addressed devices to create database records Configuration and control individual or groups of addresses. Once configured, the search engine can find devices by individual address or by group address Use Search buttons to find individual or group addresses and press then press the add button to move them into the Modification window. SCENE BUILDER - Scenes of Presets are a powerful and versatile capability for controlling small to large groups of lights. Building Scenes 1. What is a Scene? - Scenes derive their name from theatrical scenes where each DALI object can be thought of as an actor within a group of actors. DALI scenes are similar. Each object can have up to16 roles and each role can be any light level between off (0) to full bright (254) or Mask (255) (or do nothing). When the director—in the form of a goto scene command—calls a scene then all the actors in the designated group go to their preassigned light level or stay at their present value if their scene value is Mask. 3. Scene Builder Master Group - Scenes typically encompass a whole room or master group. If subgroups are used they are typically organized by fixture types or geographical important groups like fixtures over a blackboard or near an entrance. Selecting the Master Group - Use the “Filter-byGroup” This will simplify the process by reducing the addresses in the Device list box to only those objects within a scene control zone. Determining Scene Numbers—Before modifying or creating a new scene, determine what scenes numbers are being called by the room scene controller(s). . fresh by erasing previous scenes. This is done by moving all the room objects into the Modification window and choosing the Mask level Start Fresh—When creating a new scene, start Page 27 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 QUERY - DALI property values are stored in the Admin database the DALI objects themselves. Use query to display and refresh these values. BUS BRIDGING - Need to control an entire facility from a single switch? Bridging does the job. DALI BALLAST REPLACEMENT - With 54 properties, an operating DALI ballast can store a lot of data. The Admin Lite ballast replacement program is designed to assist by maintaining all those settings in a backup database where they can be quickly accessed and uploaded to replaced ballasts. ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page 28 105.7.2 DAYLIGHTING spaces without manual controls but in offices, classrooms, and other spaces with manual controls a fixed What is Daylighting? - Like a thermostat maintaining a setpoint is often in conflict with user wishes. constant temperature, daylighting seeks to maintain a TM constant light level. This is accomplished by measuring Lumestat - CoreNet’s LumeStat system is designed for daylighting areas with manual controls. Like fixed ambient light in a space and then adjusting the electric setpoint control, it maintains a setpoint but that setpoint lights up or down. is re-captured each time the lights are adjusted. Methods of Control - Lighting control systems are eiSetpoint Max - Maximum allowed setpoint typically set ther switched or continuous dimming. Both methods at or near the 100% electric light level. Determined by work with a setpoint but because a switched system is System Administrator to prevent capturing overly bright either on or off setpoint maintenance is more coarse setpoints from being captured by the LumeStat when than a continuous dimmed system. bright sunlight is present. Fixed Setpoint - Conventional daylighting used a fixed or static setpoint. This approach works well for public Definitions SETPOINT CAPTURE What is Setpoint Capture? - Daylight sensor readings must be calibrated to account for mounting height, location, room geometry, reflectance, and electric lights output. Start - After selecting a controller, use the LL button (14.11) to read the current light level and then fill in the daylighting properties discussed below before going to then next page to schedule the capture. Controller - Select from pull down list. Zone Control Method - Select “Switched” for relay systems and “Dim” for continuous dimming. Daylight Mode - For dim systems select Fixed or LumeStat. Sensitivity - Update frequency in seconds. Xmit Group - DALI group being controlled. Setpoint Capture Screen SETPOINT CAPTURE SCHEDULE Set a time and date for calibration and setpoint capture . Setpoint Capture Schedule Page 29 ©2010-11 Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com 105.7.2 System Scheduling - CoreNet’s powerful scheduling software for systems with CoreNet System Controllers allows Owners to customize the operation of their facilities. Who? - Create selection sets of ballasts, relays, controllers, and sensors. What? - Create execution scripts for the selection sets to include: GoTo level GoTo scene Enable or disable Occupancy sensors Enable or disable Daylight sensors Enable or disable controllers/buttons When? - Schedule single or recurring scripts to set or astronomical times. ©2010-11Starfield Controls Inc. All rights reserved. Subject to change without notice. Office 303.427.1661 • Fax 303.255-0701 Web: www.starfieldcontrols.com Page 30 Starfield Controls Founded in 1997, Starfield Controls is a digital lighting control specialist offering: Hardware Software Design Tools System Engineering, Startup, and Support Digital Since 2002 Starfield Controls received the lighting industry’s highest awards at Lightfair 2002 for the introduction of America’s first line of DALI compliant controls. Representatives New York Washington DC Baltimore Boston Connecticut Ohio Dallas Los Angeles San Diego Seattle ...and growing fast. Call for updates or check our website. 1 Starfield Controls Inc. Westminster, CO 80234 Off 303.427.1661 Fax 303.255.0701 ww.starfieldcontrols.com 1 KCCC Ballroom photos by michael spillers