GPRO Construction Management MRc5 Reporting Template

Transcription

GPRO Construction Management MRc5 Reporting Template
G|PRO
Green Professional Building Skills Training
GPRO Construction Management
Classroom Exercise 7.1: Reporting Templates & Cutsheets
Instructions:
1.
2.
3.
Distribute the 4 Credit Reporting Templates to 4 students. Those students will act as the CMs and
be responsible for collecting the required information from the cutsheets.
Distribute the cutsheets to the remaining students. These students will act as subcontractors and
submit cutsheets to deliver verification data to the appropriate CM.
Look for things like:
• Some sheets just say “low VOC” – not OK by itself – needs to list g/L
• Some sheets you need to look hard to find the info
• Some sheets cover more than one product so proof of actual product use is important.
• Encore LEED product says “LEED approved” which is nonsense. It does list VOC limits also
but is a good opportunity to discuss greenwashing.
• This exercise is intended to simulate the flurry of paperwork that comes with the submittal
phase of a job. It’s OK if it’s a little chaotic!
Reporting Templates:
•
•
•
•
MRc4: Recycled Content
MRc5: Regional Content
IEQc4.1: Low-Emitting Adhesives & Sealants
IEQc4.2: Low-Emitting Paints and Coatings
Cutsheets:
•
•
Recycled and Regional cutsheets (10 items – 20 pages)
VOC cutsheets (10 items – 22 pages)
GPRO Construction Management
IEQc4.1 Reporting Template
Low-Emitting Materials: Adhesives & Sealants
Exercise Instructions: Complete the following template. Find product data in the
provided cut sheets and allowable VOC content date in the LEED Low-Emitting
Materials Standards charts for IEQ Credit 4.1, provided on the following pages.
CONTRACTOR / INSTALLER INFORMATION
Company :
Address:
Contact:
Phone:
LIST OF ALL INDOOR ADHESIVES, SEALANTS AND SEALANT PRIMER PRODUCTS:
Please provide the required data for each indoor adhesive, sealant, and sealant primer product used on
this project.
PRODUCT NAME
PRODUCT MFR.
PRODUCT VOC
CONTENT (g/L)
SCAQMD
ALLOWABLE
VOC CONTENT
(g/L)
SOURCE OF
VOC DATA
LIST OF ALL INDOOR ADHESIVES, SEALANTS AND SEALANT PRIMER PRODUCTS:
Please provide the required data for each aerosol adhesive product used on this project.
PRODUCT NAME
PRODUCT MFR.
PRODUCT VOC
CONTENT (g/L)
GREEN SEAL
GS-36
ALLOWABLE
VOC CONTENT
(% by weight)
SOURCE OF
VOC DATA
GPRO CM IEQc4.1 – Low-Emitting Materials: Adhesives & Sealants Reporting Template; Page 1/1
GPRO Construction Management
IEQc4.2 Reporting Template
Low-Emitting Materials: Paints & Coatings
Exercise Instructions: Complete the following template. Find product data in the
provided cut sheets and allowable VOC content date in the LEED Low-Emitting
Materials Standards charts for IEQ Credit 4.2, provided on the following page.
CONTRACTOR / INSTALLER INFORMATION
Company :
Address:
Contact:
Phone:
LIST OF ALL INDOOR PAINT AND COATING PRODUCTS:
Please provide the required data for each indoor topcoat paint, anti-corrosive and/or anti-rust product(s)
used on this project.
PRODUCT NAME
PRODUCT MNF.
PRODUCT VOC
CONTENT (g/L)
GREEN SEAL
GS-36
ALLOWABLE
VOC CONTENT
(% by weight)
SOURCE OF
VOC DATA
GPRO CM IEQc4.2 – Low-Emitting Materials: Paints & Coatings Reporting Template; Page 1/1
GPRO Construction Management
MRc4 Reporting Template
Recycled Content
Exercise Instructions: Complete the following template. Find credit information in the
previous LEED MRc4 Recycled Content Credit page.
CONTRACTOR / INSTALLER INFORMATION
MANUFACTURER INFORMATION
Company:
Company:
Address:
Address:
Contact:
Contact:
Phone:
Phone:
MATERIAL INFORMATION:
DEFAULT MATERIALS VALUE: Based on the total construction costs
=Total construction costs x 0.45
(Hard costs for CSI Divisions 2-10 only)
$
ACTUAL MATERIAL VALUE: Based on actual material costs
(excluding labor and equipment)
(Hard costs for CSI Divisions 2-10 only)
$
MATERIAL
NAME
MFR.
MATERIAL
COST ($)
POSTCONSUMER
RECYCLED
CONTENT (%)
PRECONSUMER
RECYCLED
CONTENT (%)
RECYCLED
CONTENT
INFO.
SOURCE
TOTAL VALUE ($) OF POST-CONSUMER CONTENT
$
TOTAL VALUE ($) OF PRE-CONSUMER CONTENT
$
TOTAL COMBINED RECYCLING CONTENT VALUE ($):
POST-CONSUMER + 1/2 PRE-CONSUMER CONTENT
$
COMBINED RECYCLED CONTENT VALUE AS A PERCENTAGE OF TOTAL
MATERIALS COST
$
*NOTE: To qualify for the credit the percentage of recycled content (post-consumer + 1/2 pre-consumer must be at least 10% of the
total materials cost)
GPRO CM MRc4 – Recycled Content Reporting Template; Page 2/2
GPRO Construction Management
MRc5 Reporting Template
Regional Material Reporting
Exercise Instructions: Complete the following template. Find credit information in the
previous LEED MRc5: Recycled Content Credit page.
CONTRACTOR / INSTALLER INFORMATION
MANUFACTURER INFORMATION
Company:
Company:
Address:
Address:
Contact:
Contact:
Phone:
Phone:
MATERIAL INFORMATION:
DEFAULT MATERIALS VALUE: Based on the total construction costs
=Total construction costs x 0.45
(Hard costs for CSI Divisions 2-10 only)
$
ACTUAL MATERIAL VALUE: Based on actual material costs
(excluding labor and equipment)
(Hard costs for CSI Divisions 2-10 only)
$
MATERIAL
NAME
MFR.
TOTAL
MATERIAL
COST ($)
PERCENT
COMPLIANCE
COMPLIANT
PRODUCT
VALUE
HARVEST
DISTANCE
(MI)
MFR.
DISTANCE
(MI)
HARVEST
MFR /
LOCATION
INFO
SOURCE
TOTAL VALUE ($) OF LOCALLY MANUFACTURED AND EXTRACTED MATERIALS
$
LOCAL MATERIAL VALUE AS PERCENTAGE OF TOTAL MATERIAL COSTS
$
*NOTE: To qualify for 1 point, the local materials value must be at least 10%. To qualify for 2 points, the local value must be at least
20%.
LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS
GPRO CM DOC #MRc5 Regional Materials Template
Page 2/2
Product Information
CP 606
Flexible Firestop Sealant
Product description
•
An acrylic based firestop sealant that provides movement
capability in fire rated joint applications
Areas of application
•
•
•
•
•
Sealing construction/expansion joints
Top-of-wall joints
Metal pipes
Cable bundles
HVAC penetrations*
For use with
Various base materials such as masonry, concrete, metal, etc.
Wall and floor assemblies rated up to 3 hours
Examples
•
•
Where a gypsum wall assembly meets the underside of
a metal or concrete deck
Sealing expansion joints to impede the passage of fire,
smoke and toxic fumes
Sealing around HVAC penetrations through fire-rated assemblies
LA
SSIFIE
D
•
Internationally tested and approved
C
•
•
R
FILL, VOID OR CAVITY MATERIALS
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
FOR USE IN JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
System advantages/Customer benefits
•
•
•
•
Paintable
Meets 500 cycle requirements (ASTM E 1399 & UL 2079)
Smoke, fume and water resistant
Easy clean up with water
CP 606 Flexible Firestop Sealant
Description
Color
Package
Contents
CP 606, tube
red
10.5oz (310 ml)
CP 606, foil
white
(Qty 20) 20.2oz (600 ml)
CP 606, foil
red
(Qty 20) 20.2oz (600 ml)
CP 606, pail
red
5 gallons (19 liter)
CB 200 Pl-300/310 ml Dispenser
600 ml Foil Dispenser
*
26
Volume
Item No.
18 in
36 in3
36 in3
1155 in3
3
00337191
00314272
00337192
00337193
00055205
00024669
For metal ducts with damper, consult damper manufacturer.
Saving Lives through innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com
Installation Instructions
CP 606
Flexible Firestop Sealant
Technical Data
CP 606 Flexible Firestop Sealant
(at 73°F (23°C) and 50% relative air humidity)
Density:
Approx. 1.5 g/cm3
Color:
Red and White
Application temperature:
40°F (5°C) to 77°F (25°C)
Skin-forming time:
Approx. 15 min.
Curing rate:
Approx. 1/16” in 3 days
Volume shrinkage:
Less than 20%
Movement capability:
Approx. 10%
Temperature resistance:
-40°F (-40°C) to 176°F (80°C)
Surface burning characteristics:
Flame spread: 0
(ASTM E84-96)
Smoke development: 5
Sound transmission classification:
50
(ASTM E 90-97)
Product description
•
An acrylic based firestop sealant that provides movement
capability in fire rated joint applications
Product features
•
•
•
Silicone free
Halogen, asbestos and solvent free
UV-resistant
Tested in accordance with
•
•
•
•
•
UL 2079
ASTM E 1399
UL 1479
ASTM E 814
ASTM E 84
Approvals
ICBO Evaluation Service, Inc.
California State Fire Marshal
City of New York
Report No. ER-5614
Listing no. 1452-1200:112
MEA 100-99-M
Installation instructions for CP 606
Joint installation
Firestop
System
1. Clean opening
Duct installation
2. Insert backing
material
3. Apply CP 606
4. Smooth CP 606
5. Fasten identification
plate (if required)
Firestop
System
1. Clean opening
2. Insert backing
material
3. Apply CP 606
4. Smooth CP 606
Opening
1. Clean the opening. Joint sides and surfaces to which CP 606 will be
applied must be sound, dry and free from dust, oil and grease.
Application of firestop
2. Insert fill of mineral wool or backer (as required).
3. Apply firestop over backer.
4. Smooth firestop sealant with a trowel before the skin forms.
Once cured, CP 606 can only be removed mechanically.
5. For maintenance reasons, a penetration seal could be permanently
marked with an identification plate. In such a case mark the
identification plate and fasten it in a visible position next to the seal.
Notice about approvals
• When using Hilti CP 606 Flexible Firestop Sealant, check that the
joint or pipe application has been sealed according to the applicable
drawing in the UL Fire Resistance Directory or Hilti Firestop Manual.
5. Fasten identification
plate (if required)
Not to be used…
• On areas immersed in water
Safety precautions
• Keep out of reach of children
• Read the Material Safety Data Sheet
• Eyes and hands must be suitably protected
• Avoid contact with eyes/skin
• Only use in well ventilated areas
Storage
• Store only in the original packaging in a location
protected from moisture at a temperature of 40°F (5°C) to
77°F (25°C)
• Observe expiration date on package
Saving Lives through innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com
27
MSDS No.:
Revision No.:
Prep. Date:
Page:
®
Hilti (Canada) Limited
267C
001
25 April, 2000
1 of 2
MATERIAL SAFETY DATA SHEET
Product identifier:
CP 606 Flexible Firestop Sealant
Product use:
Fire resistant acrylic based sealant for use in fire rated joint applications
Supplier:
Hilti (Canada) Limited, 6790 Century Avenue, Suite #300, Mississauga, Ontario L5N 2V8
Originator
Hilti, Inc., P. O. Box 21148, Tulsa, Oklahoma, USA 74121
Emergency number:
Chem-Trec: 1 800 424 9300
INGREDIENTS INFORMATION
Ingredient
Calcium carbonate
Water
Isononyl phthalate
Polybutene
Ethylene glycol
Pigment
CAS Number
01317-65-3
07732-18-5
28553-12-0
09003-29-6
00107-21-1
01309-37-1
% (wt.)
50 - 55
15 - 20
10 - 15
01 - 05
01 - 05
01 - 05
LC50, (rat)
N/Av
N/Av
N/Av
N/Av
N/Av
N/Av
LD50 (rat)
N/Av
N/Av
N/Av
N/Av
4700 mg/kg
N/Av
TLV
N/Ap
N/E
N/E
N/E
N/E
N/Ap
STEL
N/E
N/E
N/E
N/E
N/A
N/E
PHYSICAL PROPERTIES
Appearance / Physical state:
Red paste.
Odour:
Mild odour.
Specific gravity (at 20ºC):
1.55
Odour threshold:
Not determined.
Vapour pressure (at 20ºC):
Not applicable.
Vapour density:
Not applicable.
Evaporation rate:
Not determined.
Boiling point:
Not determined.
Freezing point:
Not determined.
pH:
Not determined.
Coefficient of H20 / oil distrib:
Not determined.
Solubility in water:
Miscible.
FIRE AND EXPLOSION DATA
Flash point / Method:
Nonflammable.
Flammable limits:
Not applicable.
Conditions of flammability:
Not applicable.
Auto-ignition temperature:
Not applicable.
Means of extinction:
Not applicable. As appropriate for surrounding fire (e.g. Water, CO2, Dry Chemical, Foam).
Special fire fighting
procedures:
None known. A NIOSH-approved self-contained breathing apparatus (SCBA) should be worn
when fighting fires involving chemicals.
Hazardous combustion
products:
Not determined.
Sensitivity to mechanical
impact / static discharge:
Not susceptible to mechanical impact or to a static discharge.
REACTIVITY DATA
Stability:
Stable.
Conditions of reactivity:
None known.
Hazardous decomposition
products:
Not determined.
Incompatible materials:
Strong oxidizing agents.
TOXICOLOGICAL PROPERTIES
Routes of exposure:
Skin contact
Skin absorption
Eye contact
Inhalation
Ingestion
Exposure limits:
See “Ingredients” section above.
Acute effects of exposure:
Eyes – Slightly alkaline material; can cause irritation but injury is unlikely. Skin - Can cause
irritation with some individuals. Inhalation - No effects expected. Ingestion - Not a likely
route of exposure. Effects of ingestion have not been determined.
Chronic effects of exposure:
None known.
Synergistic materials:
None known.
HILTI ® is a registered trademark of Hilti Corp.
FIRST AID MEASURES
Eyes:
Flush immediately with plenty of water. Call a physician if symptoms occur.
Skin:
Wash with soap and water. Seek medical attention if any effects persist.
Inhalation:
No ill effects expected. Should discomfort occur, move to fresh air.
Ingestion:
Do not induce vomiting unless large amounts are ingested. If conscious, give plenty of water
to drink. Never give anything by mouth to an unconscious person. Contact a physician
immediately.
Other:
Referral to a physician is recommended if there is any question about the seriousness of the
injury/exposure
CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT
Engineering controls:
General (natural or mechanically induced fresh air movements).
Eye protection:
As appropriate for the work area.
Skin protection:
Cloth gloves are suitable.
Respiratory protection:
None normally required.
Other:
No additional measures are normally required.
PRECAUTIONS FOR SAFE HANDLING AND USE
Handling procedures and
equipment:
For industrial use only. Keep container sealed when not in use to prevent curing of the
product. Avoid contact with the eyes and skin. Practice good hygiene; i.e. wash after using
and before eating or smoking.
Storage requirements:
Keep out of reach of children. Store in a cool dry area. Keep from freezing. Shelf life is one
year from date of manufacture if stored between 40° and 77° F (5 - 25° C).
Spill, leak or release:
Immediately wipe away spilled material before it hardens. Place in a container for proper
disposal in accordance with all applicable local, state, or federal requirements.
Waste disposal:
Consult with regulatory agencies or your corporate personnel for disposal methods that
comply with local, provincial, and federal safety, health and environmental regulations.
Special shipping instructions:
Avoid temperature extremes. Keep from freezing.
REGULATORY INFORMATION
WHMIS classification:
D2B
HMIS codes:
Health 0, Flammability 0, Reactivity 0, PPE A
TDG shipping name:
Not regulated.
PREPARATION INFORMATION / CONTACTS
Prepared by:
Hilti, Inc., Tulsa, OK USA
Customer Service:
Hilti (Canada) Limited, Mississauga, Ontario; 1 800 363 4458
Health / Safety contacts:
Hilti, Inc., Tulsa, OK USA; 1 800 879 6000 Steve Gerrard (x6309), Jerry Metcalf (x6704)
Abbreviations used:
N/E = None Established. N/A = Not Applicable. N/Av = Not Available. H = Hours. HMIS:
Hazardous Materials Identification System
Emergency phone number:
1 800 424 9300
The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or
warranty of any kind expressed or implied is made with respect to the information provided.
MSDS 267C, Page 2 of 2
ENCORE LEED
ENCORE LEED is a fast grabbing, ultra-high solids, heavy commercial carpet adhesive designed for hard to
hold direct glue and double stick installations for carpet to pad. ENCORE LEED commercial carpet adhesive
contains 20% Post Consumer content, is packaged in a 75% resin (recycled) pail and exceeds California
SCAQMD Rule #1168 low VOC criteria. ENCORE LEED qualifies for LEED rating credits, for low emitting
materials and for Post Consumer Content requirements.
The installation site must be acclimated with HVAC in operation. The floor and room temperature, as well as
flooring materials and adhesive, must be maintained at 65°- 95° F, and the humidity below 65% for 48 hours
prior to, during, and after the testing and installation. Follow floorinstructions and proper adhesive application rate.
Concrete substrates must be tested for moisture vapor emissions rate (MVER) per Calcium Chloride Test
Method ASTM F1869, or for in-situ Relative Humidity per ASTM F2170. The surface pH must not exceed 9.0.
MVER of concrete substrates must be below 5.0 lbs., or with in-situ Relative Humidity below 80% per ASTM
F2170. Site conditions, floor preparations, and moisture and alkalinity must comply with those specified by the
Carpet & Rug Institute (CRI 104 or 105). Do not use on substrates that have been chemically cleaned.
Advantages
Low Odor
Water and alkali resistant
Good rebonding characteristics
Easy to trowel
CRI Green Label Plus Approved
20% Post Consumer Content
Contributes to LEED Credits
Open Time
Approximately 20-30 minutes (high humidity and low temperatures will affect drying time)
Trowel Recommendations
Floor Covering
Smooth back carpets
Most commercial backings
Rough back carpets and double stick
Trowel Recommendation
-Notch
-Notch
-Notch
Coverage
10 15 square yards/gallon
8 10 square yards/gallon
5 8 square yards/gallon
Shelf Life
One year from date of manufacture in an unopened container
Use With:
Carpet: Barrier Back, Polypropylene (ActionBac® ), Enhancer / Enhancer Plus Series, Axminster, Wilton, Needle
Punched, Latex Unitary Back, Attached Polyurethane Backed Carpet, Woven, Rubber and Foam Backs. Not to
be used with vinyl backed floorings of any kind.
This adhesive is tested by the Carpet & Rug Institute and carries the CRI Green Label. This product is not
photochemically reactive as defined by California rules 102 and 443. VOC content is below that established by
California SCAQMD Rule 1168. 04/23/2009
XL Brands
4284 South Dixie Hwy
Resaca, GA 30735 - 800.367.4583
Material Safety Data Sheet
Encore LEED
Revised: 04/23/2009
Prepared by: J. Long
Title: Technical Director
XL Brands
4284 South Dixie Hwy; Resaca, GA 30735
Telephone No.: 800-367-4583
24-hour Emergency:
Chemtrec 1-800-424-9300
Product Identification:
Product Class:
Aqueous Adhesive
Product Name: Ultra Premium Carpet
Adhesive
Trade Name:
Encore LEED
Hazardous Ingredients: None known.
*All components of this product appear on the Inventory
of Chemical Substances published by the U.S.
Environmental Protection Agency (EPA) under the
authority of the Toxic Substances Control Act (TSCA).
Physical Data:
Boiling Point:
212 F
Vapor Density:
Same as water.
Evaporation Rate:
Same as water.
Appearance and Odor: Tan paste, low odor
Weight per Gallon:
9.5 lbs.
Percent Volatile by Weight: 24-26% (as water)
Solubility in Water:
Dispersible
V.O.C. (Calculated):
"zero" grams/liter
Fire and Explosion Hazard Data:
Flammable Limits:
No flashing
Flash Point:
> 212 deg. F.
Flammability Classification:
OSHA: None
DOT: None
Extinguishing Media:
CO2, chemical foam,
water fog
Special Fire Fighting Features: Wear selfcontained breathing gear when in confined
area.
Health Hazard Data:
Threshold Limit Value: Not established
Effects of Overexposure: No known chronic
overexposure effects.
Emergency and First Aid Procedure: Eye
contact may cause irritation. In case of eye
contact, flush with water for 10-15 minutes. If
irritation persists, consult a physician. Skin
Contact: prolonged contact may cause slight
irritation of the skin. Wash with soap and
water. If swallowed, consult a physician.
Inhalation: if symptomatic, move to fresh air.
Get medical attention if symptoms occur.
Reactivity Data:
Conditions to avoid: Excessive heat or cold.
Stability: Stable.
Incompatibility: None known.
Hazardous Decomposition Products: None
known; Normal (CO 2, CO).
Hazardous Polymerization: Will not occur.
Precautions for Handling and Use:
Ventilation:
Local ventilation.
Protective Gloves: Recommended.
Eye Protection:
Safety glasses.
Hygienic Practices:
Wash with soap and
water after exposure.
Respiratory Protection: Not required with
adequate ventilation.
Other Protective Equipment: None.
Spills: Cover small spills with inert absorbent,
then sweep up and place in waste disposal
container. Dispose of in accordance with
Federal, State and Local regulations.
Special Precautions/Other Comments:
Precautions to be taken in handling and
storing: Store inside at a temperature of
60° - 100° F. Do not allow product to freeze.
Other precautions: None
Transportation Data:
D.O.T. Hazard Class: Unregulated
Safecoat®
Penetrating WaterStop
Interior/Exterior
DESCRIPTION: Safecoat Penetrating WaterStop is a zero
voc, non-film forming sealer designed to improve water
resistance and repellency in a wide variety of surfaces,
including brick walls, concrete foundations, stucco, stone
and most unglazed tile. It is not toxic and low odor,
making it non-offensive to installer and occupant. It can
be used indoors instead of a typical high solvent content
sealer and is durable enough for use outdoors.
USE ON: Porous, mineral containing surfaces such as
brick, pavers, concrete block and other cementitious
materials, stone and stucco. Not suitable for wood.
PRODUCT NUMBER AND CONTAINER SIZE:
31106 (gallon) and 31306 (five gallon).
ADVANTAGES / SIGNIFICANT BENEFITS:
 Good water resistance for up to five years when
properly applied.
 Low odor, non-offensive to installer and occupant.
 Safely used by and for the chemically sensitive.
 Fights indoor air pollution
 Zero VOC content, meets or exceeds all federal and
state air quality regulations, including California.
 Contains no formaldehyde.
SURFACE PREPARATION: All surfaces must be clean,
dry, free from dirt, dust, efflorescence, grease, wax, oil,
silicone, tsp/soap, mill scale, oxidation, loose peeling paint
or varnish, or any foreign matter/contaminants. Remove
all mildew before coating any surface.
APPLICATION: Always have adequate ventilation. Apply
Safecoat Penetrating WaterStop with a brush or spray
equipment in an even and uniform manner. Do not use a
roller. For vertical surfaces start at the top and work
down. Keep a wet edge. Always test a sample for
suitability prior to full use. Avoid puddling on horizontal
surfaces. Apply one coat only. Do not dilute. Note: these
instructions are intended to be general only and not
exhaustive.
The applicator should determine which
preparation and techniques are best suited to the specific
surface.
CLEAN-UP: Clean tools and equipment while still wet with
a solution of SafeChoice Super Clean and warm water.
DRYING/CURING TIME: 24 hours full cure in moderate
humidity and heat.
LIMITATIONS: Unlike conventional sealers, Safecoat
sealers are made without formaldehyde preservatives or
toxic mildewcides or fungicides. Do not contaminate.
Store in airtight containers. Do not use when indoor or
surface temperature is below 55°F. Do not freeze. Do not
apply where product will be immersed in water, such as
fountains, pools or below ground area.
HEALTH PRECAUTIONS: As with all coatings and
sealers, keep container tightly closed and out of the reach
of children. Do not take internally. Always use adequate
ventilation. If you are chemically sensitive, always test for
personal tolerance.
LIMITED LIABILITY: Safecoat® products are guaranteed
not to be defective when properly applied. Liability express
or implied is limited to replacement of product or refund of
purchase price and does not include liability for labor costs
or consequential damages. Variable factors out of
manufacturer’s control, such as environmental conditions,
application techniques, and surface conditions are critical
to results obtained. Users are expected to exercise
reasonable care to determine suitability of the product for
each application. This limited warranty may not be
modified or extended by manufacturer’s representatives,
distributors or dealers of AFM products. Always test in
small, inconspicuous areas before application to the
entire surface.
COVERAGE: Most surfaces, 200-300 square feet per
gallon. Natural limestone, 300-500 square feet per gallon.
AMERICAN FORMULATING AND MANUFACTURING
3251 Third Avenue, San Diego, CA 92103 • Tel: 619-239-0321 Fax: 619-239-0565
MATERIAL SAFETY DATA SHEET
Prepared according to 29 CFR 1910.1200
N/A = Not applicable
Revised 9/30/08
SECTION 1 - PRODUCT IDENTIFICATION
Trade Name: Safecoat Penetrating WaterStop
Product I.D.# & Color: 3106 Clear
Product Class: Waterborne Sealer
Supplier's Name: American Formulating & Manufacturing
Telephone #: (619) 239-0321
Fax # 619-239-0565
Address: 3251 Third Avenue, San Diego, CA 92103
Emergency Phone (MSDS Information): (619) 239-0321 or (562) 693-0872
D.O.T. Emergency Phone Number: (562) 693-0872
US DOT Hazard Shipping Class: Not regulated - aqueous
D.O.T. Labels/Placards Required: No
OSHA Class: 29CFR 1910.1200 Non-hazardous
SARA TITLE III Emergency & Community Right to Know:
Section 311/312 Categorizations (40 CFR 370): Not a hazardous chemical
Section 313 Information (40 CFR 372): This product does not contain a chemical
which is listed in Section 313 above de minimis concentrations.
SECTION 2 – INGREDIENTS
Water
CAS #: 7732-18-5
Silicone Solution
CAS #: Mixture
Exposure limits: >200 @ 68degF
Potassium Hydroxide
CAS #: 13100-58-3
ACGIH TLV & OSHA PEL 2 mg/m3 (ceiling)
Weight Percent: 85–90
Weight Percent: 9–10
Weight Percent: 1-2
Suspected Cancer Agents: Federal OSHA: No NTP: NO IARC: No
known.
HMIS Codes: H-1 F-0 R-0 P-B
None
SECTION 3 - PHYSICAL DATA
Boiling Point: ........................................................................100 C/212 F
Melting Point: .......................................................................N/A
Vapor Density:......................................................................Heavier than air
% Volatile by Volume: ..........................................................96.19%
LBS/GAL Theoretical: ..........................................................8.56+or- .15
Solubility in Water: ...............................................................Dilutable
Vapor Pressure, mmHg @ 20degC: ....................................N/A
Evaporation Rate:.................................................................Slower than ether
% Volatile by Weight............................................................96.55%
Specific Gravity (Water=1):..................................................1.03
VOC Material:.......................................................................0 g/l, 0.00 lb./gal
VOC Material less H20: ......................................................0 g/l, 0.00 lb./gal
pH………………………………………………………………..11 – 13 dilute solution
SECTION 4 - FIRE & EXPLOSION HAZARD DATA
Flash Point: N/A non-combustible
Flammable limits in air, volume % - lower LEL: N/A Upper UEL: N/A
Fire Extinguishing Media: Water, carbon dioxide, dry chemical
Personal Protective Equipment: Self-contained breathing apparatus (pressuredemand MSHA/NIOSH approved or equivalent) and full protective gear may be
worn if desired, but not necessary for normal use.
Autoignition Temp.: N/A
Special Fire Fighting Procedures: Use water (fog) to cool closed containers.
Wear self contained breathing apparatus.
Unusual Fire & Explosion Hazards: Closed containers may explode due to the
build up of steam pressure when exposed to extreme heat. Material can splatter
above 100°C/212°F. Polymer film can burn.
SECTION 5 - HEALTH HAZARD INFORMATION & FIRST AID
Threshold Limit Value: See Section 2 for hazardous ingredient information
Symptoms of Overexposure
Symptoms and Effects of Short Term Exposure: Acute. Primary route of
entry:
Swallowing: May cause gastrointestinal irritation, nausea, vomiting
and diarrhea.
Inhalation: Inhalation-spray mists may cause mild respiratory
irritation.
Eye Contact: Liquid splashed into the eye may cause transient eye
irritation.
Skin Absorption: None known.
Symptoms and Effects of Repeated Overexposure: Chronic - None known.
Medical Conditions Generally Aggravated by Exposure: None known.
Emergency & First Aid Procedures:
Inhalation: Remove from exposure. Provide plenty of fresh air.
Splash (eyes): Flush immediately with large amounts of water for at least 15
minutes, lifting upper and lower eyelids occasionally. Take to a physician for
medical treatment.
Splash (skin): Remove with soap and water. Remove contaminated clothing.
Supply copious amounts of fresh water to the skin areas to rinse material away.
Ingestion (Swallowing): Consult with physician, hospital emergency room, or
poison control center immediately. Only if conscious, give 2 glasses of water to
drink.
Notes to Physician: Any treatment that might be required for overexposure
should be directed at the control of symptoms and the clinical conditions.
SECTION 6 - REACTIVITY DATA
Stability: Stable, however avoid temperatures above 177°C/350°F, the onset of
polymer decomposition.
Incompatibility (materials to avoid): Avoid materials that are water reactive,
highly alkaline or highly acidic.
Hazardous Decomposition by-products: CO, CO2 on combustion
Hazardous Polymerization: Will not occur.
Conditions to Avoid: Excess heat may cause containers to rupture. Avoid
temperatures below 45°F or freezing conditions.
SECTION 7 - SPILL, DISPOSAL PROCEDURES; ENVIRONMENTAL DATA
Steps to be taken in case material is released or spilled: Confine in small
area; contain and remove with inert absorbent (sand, earth, etc.). Place in proper
container for proper disposal. CAUTION - Keep out of waterways, drains, sewers
by diking. Keep spectators away. Floor may be slippery. Use care to avoid
falling.
Waste Disposal Method: Place contaminated material in suitable sealed metal
containers for disposal. Do not incinerate closed containers. Use non leaking
containers, seal tightly and label properly. Do not pour contaminated paint back
into unused paint. Do not throw liquid paint into the trash. Where allowed by
local laws (check with local regulatory agencies) allow liquid waste materials to
dry out before disposing into trash containers. Take all liquid unused paint that
cannot be used to approved recycling centers, paint roundups, or county facilities
that are approved to take unused paint at collection sites. Contact state, county,
city health services or fire departments to find nearest collection centers. Do not
dispose of waste into water streams or storm water sewers. Do not mix with
other kinds of waste. Dispose all waste in accordance with local, state and
federal regulations.
RCRA Classification: As produced, this product is not a waste. If discarded as
is, it is not classified a “Hazardous” waste under RCRA. This product is not
ignitable, corrosive, reactive, or toxic; therefore is not defined as hazardous by the
EPA.
Environmental Hazards: None known.
SECTION 8 - SPECIAL PROTECTION INFORMATION
Respiratory Protection: If applied by spraying, use an appropriate, properly
fitted NIOSH/MSHA approved respirator to remove spray mist. Good room
(mechanical) ventilation should be sufficient protection against vapors from
product. If further protection is desired or if persons are sensitive to vapors, use
a respirator with a NIOSH/MSHA approval number TC-23C-860 or TC-23C-87 or
an equivalent. Refer to OSHA 29 CFR 1910.134, “Respiratory Protection”.
Ventilation:
General (mechanical) room ventilation is expected to be
satisfactory.
Protective Gloves: None required under most conditions. If protection is
desired, plastic, nitrile or latex rubber will provide adequate protection.
Eye Protection: Safety glasses or goggles with side shields if splashing may
occur. Use goggles when spraying, ANSI Z87.1 or approved equivalent.
Other Protection: Eye wash or copious amounts of water as a precautionary
measure is suggested. Other equipment not likely to be needed.
SECTION 9 - STORAGE & SPECIAL HANDLING
Storage Temperature: Min. 45degF - Max. 120degF/Indoor and outdoor = OK
This product should be stored at room temperature to prolong shelf life. Keep
containers in a cool, dry place. Avoid subjecting this product to extreme
temperature variations and freezing. Adverse conditions can cause emulsion
coagulation.
KEEP CONTAINER CLOSED. KEEP OUT OF REACH OF CHILDREN. DO
NOT TAKE INTERNALLY. DO NOT GET IN EYES. IF PRODUCT IS
SPRAYED, PREVENT PROLONGED OR REPEATED BREATHING OF SPRAY
MIST. USE ADEQUATE VENTILATION WHEN USING THIS PRODUCT. USE
GOOD HYGIENE PRACTICES AND WASH AFTER USING PRODUCT.
NOTICE: The data and recommendations presented herein are based upon our
research and the research of others, and are believed to be accurate. No
guarantee of their accuracy is made, however, and the product discussed is
distributed without warranty, expressed or implied, and the person receiving such
product shall make his own determination of the suitability thereof for his
particular purpose. The use of this information and the conditions and use of this
product are controlled by the user, and it is the responsibility and obligation of the
user to determine the conditions of safe use of this product. If persons using this
product are chemically sensitive, a test for personal tolerance is recommended.
August 29, 2005
Attention:
Dow Corning Customer
Reference:
LEEDs® Credit Contribution of Dow Corning ® Silicone Sealants
Thank you for your inquiry concerning LEEDs® (Leadership in Energy and Environmental Design)
credits for Dow Corning® Silicone Sealants. There are three credits for LEED® rating system that
apply to our sealants and are listed below. These credits are Credit 5.1 of section MR, Credit 4.1 of
section EQ, and Credit 4.2 of section EQ. There is one specific credit listed below, Credit 4.1 of
section MR, that cannot be taken, but questions have come up in the past concerning this credit. Refer
to the specific LEED® literature for details concerning credits and when they can be taken.
Section MR (Materials and Resources), Credit 5.1 This credit relates to products manufactured within
500 miles of the building site location. The manufacturing site for the majority of our sealants is
located in Elizabethtown, Kentucky, zip code 42701. Refer to the LEED® literature and this specific
credit for details and confirm your site is within 500 miles of our manufacturing location.
Section EQ (Indoor Environmental Quality), Credit 4.1 Dow Corning® Silicone Sealant VOC values
fall below the applicable VOC limit listed within this credit. This limit is 250 g/l (grams/liter) and is
set by the South Coast Air Quality Management District (SCAQMD) Rule #1168 requirements and the
Bay Area Air Quality Management District Regulation 9 (BAAQMD), Rule 51 requirements. The
sealant primer limitations set forth by the SCAQMD are 250 g/L on non-porous substrates and 775 g/L
for porous substrates. Here is a listing of several of the Dow Corning® Silicone Sealants and Primers
and their VOC values. As you can see from the primer information, Dow Corning® P5200 Adhesion
Promoter credit can be taken for any substrate while Dow Corning® 1200 Prime Coat credit can only
be used for porous substrate applications. Please contact Dow Corning if a VOC value is needed for a
product not listed below.
Dow Corning Corporation
Midland, Michigan 48686-0994
Phone: (989) 496-4000
www.dowcorning.com
V.O.C. Content
< 50 g/L (gram per liter)
< 80 g/L
< 40 g/L
< 90 g/L
Sealant Products (All colors)
Dow Corning® 790 Silicone Building Sealant
Dow Corning® 791 Silicone Weatherproofing Sealant
Dow Corning® 795 Silicone Building Sealant
Dow Corning® 756 SMS Building Sealant
Dow Corning® 983 Silicone Structural Adhesive (2 part)
White Base
Black Curing Agent
After Mixing Base and Curing Agent
Dow Corning® 995 Silicone Structural Glazing Sealant
Dow Corning® Contractors Weatherproofing Sealant
Dow Corning® Contractors Concrete Sealant
< 10 g/L
< 160 g/L
< 40 g/L
< 50 g/L
< 45 g/L
< 55 g/L
Primers (All colors)
Dow Corning® 1200 Prime Coat
Dow Corning® 1205 Prime Coat
Dow Corning® P5200 Adhesion Promoter
Dow Corning® Primer C
Dow Corning® Construction Primer P
V.O.C. Content
< 775 g/L
< 870 g/L
< 95 g/L
< 860 g/L
< 865 g/L
Section EQ (Indoor Environmental Quality), Credit 4.2 This credit also relates to the VOC content of
paints and coatings like Dow Corning® AllGuard Silicone Elastomeric Coating. However, this credit
relates to indoor applications and Dow Corning® AllGuard Silicone Elastomeric Coating is typically
an exterior coating. If needed, the VOC value is listed below. Refer to this specific LEED® literature
for details concerning credits and when they can be taken.
Dow Corning® AllGuard Silicone Elastomeric Coating
< 55 g/L
Section MR (Materials and Resources), Credit 4.1 This credit relates to recycle content of materials.
In the past, customers have asked about recycle content, but you will not be able to take any credits.
The Post-Consumer Recycled Content and the Post-Industrial Recycled Content is 0%.
Further LEED® information is available on the U.S. Green Building Council web site at
www.usgbc.org
Thank you for your continued interest in Dow Corning Products. Feel free to contact me if you have
any questions.
Sincerely,
DOW CORNING CORPORATION
Thomas J. Jackson
Dow Corning Corporation
Technical Service Engineer
Ph: 989-496-8150
Fax: 989-496-4374
[email protected]
Trademark
LEED® is a registered trademark of the U.S. Green Building Council.
Dow Corning Corporation
Midland, Michigan 48686-0994
Phone: (989) 496-4000
www.dowcorning.com
Revision: November 3, 2008
Supersedes: NEW
Ref: W565N
G/L #: sP20092
TECHNICAL DATA SHEET
Henkel Corporation
Professional and Consumer Adhesives
Avon, OH 44011
Phone 1-800-321-0253
Fax (440) 937-7067
www.henkel.com www.stickwithpl.com
PL® 400 VOC Compliant
Subfloor & Construction Adhesive
DESCRIPTION:
OSI® PL® 400 VOC Compliant Subfloor & Construction Adhesive provides a powerful, permanent
bond and is formulated for all heavy duty interior or exterior construction. Cold weather formula for
easier extrusion and excellent adhesion in all weather conditions. Bonds dry, wet, frozen and treated
lumber to most building materials. Offers fast set and superior strength and development. Low VOC
formulation meets stringent State and Federal VOC regulations.
RECOMMENDED FOR:
PL® 400 VOC can be used in most interior and exterior construction projects either on the job or the
production line. It bonds all wood to wood assemblies dry, wet or frozen. Primarily designed for onsite bonding of sub-floor and plywood decking to joists during cold weather. PL® 400 VOC is suitable
for use in drywall, plaster, metal, masonry, concre te, brick, ceramic tile, slate, treated lumber and most
other projects requiring an adhesive. Ideal for use in prefab or modular construction.
.
NOT RECOMMENDED FOR:
Polyethylene (PE), polypropylene (PP), polytetrafluoroethylene (PTFE) and acrylic
Unlined expanded or extruded polystyrene plastic foams
Permanent water immersion
Applications requiring temperature resistance greater than 150°F or below -20°F
Mirrors, tub and shower surrounds
FEATURES & BENEFITS:
Feature
Item #
Package
Size
828444
Paper
Cartridge
10.2 fl. oz.
828447
Paper
Cartridge
28 fl. oz.
Benefits
Waterproof and Weather Resistant…………………. Great for indoor or outdoor projects
Cold weather gunnable…………………………………Eliminates “roll-up” on frozen lumber
Meets and exceeds APA AFG-01 specs…………… Can be applied directly to dry, wet or frozen
lumber
Bonds to most building materials…………………… Provides a strong, durable bond to multiple
surfaces
Gap filling…………………….………………………… Will bridge minor gaps when bonding irregular
surfaces; Reduces squeaking and splitting
High Grab……………………………………………… Reduces the use of fasteners
COVERAGE:
For a 10.2 fl. oz. cartridge:
A !” (6 mm) bead extrudes approximately 32 ft (9.5 m).
A 3/8” (9.5 mm) bead extrudes approximately 14 ft. (4.26 m).
For a 28 fl. oz. cartridge:
A !” (6 mm) bead extrudes approximately 85.8 ft (26.1 m).
A 3/8” (9.5 mm) bead extrudes approximately 38.1 ft (11.6 m).
OSI® PL® 400 VOC
Subfloor & Construction Adhesive
Page 1 of 3
Revision: November 3, 2008
Supersedes: NEW
Ref: W565N
G/L #: sP20092
TECHNICAL DATA:
Typical Uncured Physical Properties
Color:
White
Appearance:
Thick paste
Base:
Synthetic rubbe r and resins
Odor:
Solvent
Specific Gravity:
1.22
Flash Point:
9°F (-12.78 °C)
VOC Content:
3% by weight (50 g/L)
Typical Application Properties
Application Temperature:
Apply and cure between 10°F (-12°C) and 100°F
(38°C)
Repositioning Time:
15 minutes
Full Cure Time:
2 to 7 days
Cure time depends upon temper ature, humidity,
porosity of substrate and amount of adhesive
used.
Typical Cured Performance Properties
Color:
White
Cured Form:
Non-flammable solid
Service Temperature:
-20 F (-29°C) to 150 F (66 C)
Water Resistance:
Yes
Specifications:
Tested and approved for HUD-FHA application per UMB No. 60
Exceeds American Plywood Association specifications AFG-01
ASTM D 3498-93
Meets all California state CARB, OTC States and Federal VOC regulations
OSI® PL® 400 VOC
Subfloor & Construction Adhesive
Page 3 of 3
Product Specification
960 Cove Base Adhesive
PROPRIETARY PRODUCT/MANUFACTURER
1.
1.1
Proprietary Product: #960 Acrylic Cove Base Adhesive
1.2
Manufacturer:
Johnsonite, Inc.,
16910 Munn Road
Chagrin Falls, Ohio 44023
Phone: (800) 899-8916
(440) 543-8916
Fax: (440) 543-8920
Tech: Ext 297
Samples: Ext 299
Web: www.johnsonite.com
E-mail: [email protected]
1.3
Proprietary Product Description:
Construction: Johnsonite #960 Acrylic Cove Base Adhesive
is a solvent-free, nonflammable, acrylic, water-based adhesive for
the installation of Johnsonite rubber and vinyl wall base products
to most clean, dry, porous interior wall surfaces where
environmental and health concerns require an adhesive with
environmentally sensitive characteristics. The wall surfaces may
be interior plaster, gypsum wall board, unpainted concrete,
masonry, mineral-reinforced cement board or similar porous
surfaces. Johnsonite #960 Acrylic Cove Base Adhesive is not
recommended for use over vinyl wall covering, epoxy painted wall
surfaces, or similar nonporous surfaces, including sheet metal,
fiberglass, and ceramic tile. This non-flammable adhesive meets
all requirements for a Class "A" flame spread per ASTM E-84. This
adhesive is solvent-free and contains no hazardous or
carcinogenic ingredients as defined by OSHA, Federal, or State
agencies. This adhesive is not photochemical sensitive as defined
by California Rules 102 and 443.
1.3.1
1.3.2
Physical Characteristics:
Base - Acrylic Latex (water containing)
Color - Off White
Weight per Gallon, lbs. - 11.5
Consistency - Medium Paste
Open Time - Approximately 25 to 35 minutes depending on
temperature and humidity
Shelf Life - 1 year at 700 F. in unopened container
Application - 1/8" square notched trowel
Coverage per gallon - 250 - 300 linear feet of 4" wall base
Solvent - Water
Freeze/Thaw Stable - Yes
Packaging: 1 quart (12/ctn), 1 gallon (4/ctn), 3-1/2 gallon
(1/ctn), and 30 oz. cartridges (12/ctn)
3.
INSTALLATION
The installation of Johnsonite #960 Acrylic Cove Base
Adhesive and wall base materials should not begin until the work
of all other trades has been completed, especially overhead
trades. Areas to receive products shall be clean, fully enclosed,
weathertight, and maintained at a uniform temperature of at least
700 F for 24 hours before, during, and after the installation is
completed. The wall base and adhesive shall be conditioned in
the same manner. The floor and wall surfaces shall be smooth,
flat, level, permanently dry, clean and free of all foreign material,
such as dust, paint, grease, oils, solvents, curing and hardening
compounds, sealers, asphalt, and old adhesive residue. Do not
install on exterior surfaces subject to weather. Allow coiled wall
base to lay flat for 24 hours prior to installation. Apply adhesive
with an 1/8" square notched trowel on the back of the wall base
covering a minimum of 80% of the surface. Position wall base on
wall surface and hand roll utilizing a J-roller. Always roll back
towards previously installed piece or starting point. Wet adhesive
can be removed with a clean water dampened cloth. If the
adhesive has dried, use a clean cloth dampened with mineral
spirits. Do not allow solvent to penetrate seams, this can destroy
the adhesive bond.
3.1
Installation Manual: Refer to Johnsonite Wall Base Installation
Instructions for complete product installation. Adhesive container
label also provides complete installation details for this adhesive.
4.
AVAILABILITY AND COST
Available
nationwide.
4.1
5.
through
authorized
Johnsonite
distributors
WARRANTY
Limited 1 year warranty. For complete details, contact
Johnsonite or an authorized Johnsonite distributor.
5.1
6.
6.1
7.
MAINTENANCE
Not applicable
TECHNICAL SERVICES
Samples: Submittal samples for verification and approval
available upon request from Johnsonite. Samples shall be
submitted in compliance with the requirements of the Contract
Documents. Accepted and approved samples shall constitute the
standard materials which represent materials installed on the
project.
7.1
For current Installation and Maintenance Instructions, Product
Specifications, and other technical data, visit us on the web at
www.johnsonite.com or contact Johnsonite at 1-800-899-8916.
7.2
2. PRODUCT PERFORMANCE AND TECHNICAL DATA
2.1
ASTM E 84/NFPA 255 (Steiner Tunnel Test) - Class A
960 PS 040906
2006 Johnsonite, Inc. A Tarkett Company.
Product Specification
960 Cove Base Adhesive
1.
PROPRIETARY PRODUCT/MANUFACTURER
1.1.
Proprietary Product: Johnsonite #960 Acrylic Cove Base
Adhesive specifically formulated for installing Johnsonite
Rubber and Vinyl Wall Base, Millwork Wall Base, Tightlock
and Perceptions Wall Base and Vent Cove Base.
1.2.
1.3.
Manufacturer:
Johnsonite, Inc.,
16910 Munn Road
Chagrin Falls, Ohio 44023
Web: www.johnsonite.com
E-mail: [email protected]
Phone:
Tech:
Samples:
Fax:
manner. Allow coiled wall base to lay flat for 24 hours prior to
installation. A minimum temperature of 55F (13C) must be
maintained after installation.
Wall shall be smooth, flat, permanently dry, clean and free of
all foreign material such as dust, paint, grease, oils, solvents,
sealers, and old adhesive residue.
(800) 899-8916
(440) 543-8916
Ext 9297
Ext 9299
(440) 632-8920
Do not install on exterior surfaces subject to weather.
Stir adhesive before use.
Apply adhesive using the recommended trowel on the back
of the wall base covering a minimum of 80% of the surface.
Position wall base on wall surface and hand roll utilizing a
hand roller. Always roll back towards previously installed
piece or starting point
Proprietary Product Description
Johnsonite #960 Cove Base Adhesive is a nonflammable,
solvent free, acrylic water-base adhesive.
For installations over dry porous interior wall surfaces.
Contains no hazardous or carcinogenic ingredients as
defined by OSHA chemicals and meets all federal, state and
local air quality regulations.
Contributes to LEED Certification (E.Q. 4.1: Low-Emitting
Materials: Adhesives and Sealants).
CRI Green Label Plus Certified
SCAQMD Rule 1168 – VOC compliant
SCAQMD Rule 443.1 –
Less than 1 gram VOC per liter of materials
Less than 1 gram VOC per liter of coating
3.2.
Installation Manual: Refer to Johnsonite’s Installation
Instruction for complete installation details
4.
AVAILABILITY and COST
Available through authorized Johnsonite distributors
nationwide.
Limited 1 year warranty. For complete details, contact
Johnsonite or an authorized Johnsonite distributor.
Use a clean white cloth dampened with water to remove wet
adhesive from flooring and tools.
Base – Acrylic Polymer
Color – Light Tan Paste
Open Time – Approximately 25 to 35 minutes, depending on
Dried adhesive may require the use of denatured alcohol
applied to a clean white cloth. (Follow manufacturer's
precautions when using denatured alcohol.)
temperature, relative humidity, and porosity of wall surface.
Shelf Life – 1 year at 70o F (21o C) when stored in unopened,
original container in a dry area.
Traffic:
Wait 72 hours after installation before performing initial
cleaning
A regular maintenance program must be started after the
initial cleaning.
6.1.
Freeze thaw up to 5 cycles at 20F (-6.7C)
2.1.
Application:
Porous Wall 1/8” x 1/8” x 1/8” 'Square' notch trowel
Coverage
2.5" 300-350 lin.f.t/gal.
4"
200-250 lin.ft./gal.
6"
100-150 lin.ft./gal
30 oz cartage
62 to 75 lin. ft.
7.
INSTALLATION
3.1.
General Installation Requirements:
TECHNICAL SERVICES
For current Installation and Maintenance Instructions,
Product Specifications, Material Safety Data Sheet and other
technical data, visit us on the web at www.johnsonite.com or
contact Johnsonite at (800) 899-8916.
Non-Porous Wall use Johnsonite #945 Contact Bond
3.
ADHESIVE CLEAN UP and MAINTENANCE
6.
PRODUCT PERFORMANCE and TECHNICAL DATA:
2.
WARRANTY
5.
The installation of Johnsonite wall base should not begin until
the work of all other trades has been completed, especially
overhead trades. Areas to receive wall base shall be clean,
fully enclosed, weathertight, and maintained at a temperature
between 70F to 85F (18C to 29C) for 24 hours before,
during, and after the installation is completed. The wall base
material and adhesives shall be conditioned in the same
Release September 2009
Page 1 of 1
960 Adhesive PS 091509
FIRE PROTECTION SYSTEMS
part of the
®
Company
PRODUCT DATA – for LEED Green Building Rating System®
Background:
A/D products can contribute towards 19 points under the LEED Green Building Rating System®.
The LEED Green Building Rating System® does not certify construction products or materials. Instead, entire
projects are certified on the basis of overall design and in consideration of the environmental impact of the
building materials employed. This data sheet provides environmental properties, so that A/D products can be
evaluated under the LEED Green Building Rating System®.
Table of Applicable LEED Points
LEED Points
1
10
3
2
2
1
LEED Requirements
Building materials manufactured within
500 miles of the project site.
Building achieves a high level of energy
performance.
Renovation projects maintain existing
building elements.
Building materials contain recycled
content.
Low Volatile Organic Compound (VOC)
content.
Raw materials supplied within 500 miles
of the manufacturing site.
Applicable A/D Product
All
LEED Guide Reference
MR Credit 5.1
A/D Type FP
A/D Type I
All
EA Credit 1
A/D Type FP
A/D Thermal Barrier
A/D FIREBARRER Mineral Wool
A/D FIREBARRIER Pillows
All
MR Credit 4.1 and 4.2
All
MR Credit 5.2
MR Credit 1.1, 1.2 and 1.3
EQ Credit 4.1 and 4.2
1 Points – LEED MR Credit 5.1.
Building materials manufactured within 500 miles of the project site.
A/D products are manufactured at either our Toronto, Ontario facility, or our Louisa, Virginia facility. Your A/D
Technical Sales Representative can determine which facility a product batch was manufactured.
500 mile radius from Toronto, Ontario
500 mile radius from Louisa, Virginia
10 Points – LEED EA Credit 1
Building achieves a high level of energy performance.
A/D Type FP sprayed fire resistive material and A/D Type I sprayed insulation can provide a thermal insulation
value of R4 per applied inch, which is greater than the R-value achieved by most other fireproofing products.
The use of A/D Type FP or A/D Type I can contribute towards the energy performance design of a building.
3 Points – LEED MR Credit 1.1, 1.2 and 1.3
Renovation Projects Maintain Existing Building Elements
A/D Fire Protection Systems products are ideal in fire performance retrofit/upgrade situations, where existing,
unrated building elements are required to be fire-rated under modern building codes. Wooden floor assemblies,
cast iron structural columns, and other existing building elements can be upgraded to meet modern fire rating,
firestopping and thermal insulation requirements, rather than being replaced during building renovation projects.
5 Points and 1 Prerequisite
The following table outlines product data required for the application of LEED Credits MR 4.1, MR 4.2, MR 5.2,
EQ 4.1, EQ 4.2, and EQ Prerequisite 1.
Table of Environmental Data – A/D Fire Protection Systems Products
Product
% Regionally
Supplied Raw
Materials (MR Credit
5.2)a
A/D Type FP and Thermal Barrier
A/D Type 5GP, 5MD and 5EF
A/D Type 7, 7HD and 7TB
A/D Type 1XR
®
A/D FIREFILM III
®
A/D FIREFILM -S
®
A/D COLORCOAT
A/D Type I
A/D FIREBARRIER Silicone
A/D FIREBARRIER Silicone SL
A/D FIREBARRIER Intumescent Caulk
A/D FIREBARRIER Seal
A/D FIREBARRIER Seal NS
A/D FIREBARRIER SprayMastic
A/D FIREBARRIER Mortar
A/D FIREBARRIER Pillows
A/D FIREBARRIER Wrap Strip
A/D FIREBARRIER Collars
A/D FIREBARRIER Mineral Wool
A/D FIREBARRIER Putty
A/D FIREBARRIER Putty Pads
A/D FIREBARRIER Inserts
% Recycled
Content (MR
Credits 4.1 and
4.2)b
100 %
99 %
92 %
99 %
53 %
15 %
2%
1%
0
0
49 %
100 %
100 %
88 %
88 %
98 %
99 %
95 %
0%
99 %
88 %
0%
95 %
100 %
0%
0%
0%
0
0
15 %
0
0
0
0
0
0
0
9%
0
0
21 %
0
0
0
VOC Content (EQ
Credits EQ 4.1,
EQ 4.2 and
Prerequisite 1).
lbs / gal US (g/L)c
None.
None.
None.
None.
0.17 (20)
2.82 (338)
2.69 (323)
None.
0.69 (83)
0.5 (60)
0.4 (42)
0.22 (26)
1.71 (205)
None.
None.
None.
None.
None.
None.
None.
None.
None.
a
Regionally supplied raw material status is based on a 500 mile radius criteria, measured from A/D Fire
Protection Systems’ manufacturing facility. Suppliers may purchase or extract raw materials from outside this
radius. Percentages are by mass.
b
Recycled content is based on the definition of “recycled”, included in US Federal Trade Commission
document, Guides for the Use of Environmental Marketing Claims, 16 CFR 260.7 (e). This does not include
water. Recycled content is 100% post-industrial. Percentages are by mass.
c
VOC testing has been conducted in accordance with ASTM D 3960.
A/D FIRE PROTECTION SYSTEMS
420 Tapscott Rd., Scarborough, Ontario M1B 1Y4
Tel: (800) 263-4087 or (416) 292-2361 Fax: (416) 298-5887
www.adfire.com
AK, AR, AZ, CA, CO, HI, ID, LA, MT, NM, NV, OK, OR, TX, WA, WY, UT:
Tel: (888) 323-3473, Fax: (949) 458-9220
AL, CT, DC, DE, FL, GA, IA, IL, IN, KS, KY, MA, MD, ME, MI, MN, MO, MS, NC, ND, NE, NH, NJ, NY,
OH, PA, RI, SC, SD, TN, VA, VT, WI, WV: Tel: (800) 650-0881, Fax: (613) 841-7768
NB, NF, NS, PE, QC: Tel: (800) 914-6506, Fax: (450) 661-8776
AB, BC, MB, NT, NU, ON, SK, YT: Tel: (800) 263-4087, Fax: (416) 263-5887
January 25, 2006
,$.(6*-'16&&"-+#
IPS CORPORATION
EFF
™
&.D'0.*',0*').&0"#-'*"C"#-
!"#"$%&'(")*$+,-+.#/
WELD-ON® 711™ is a gray, low VOC emission, heavy bodied, medium setting, high strength PVC solvent cement for all classes and
schedules of pipe and fittings with interference fit through 12 inch (315 mm) diameter, including Schedule 80. It has good gap filling
properties and its medium set allows more working time in warm weather.
%,,&+*%-+.#/
WELD-ON 711 is for use on all types of PVC plastic pipe applications, Type I and Type II. It is suitable for use with potable water
pressure systems, irrigation, turf, conduit, sewer, drain, waste and vent systems. Ideal for use on industrial piping systems.
Detailed directions on making solvent cemented joints are printed on the container label. An installation DVD/CD covering solvent
cementing is available. It not only describes the basic principles of solvent cementing, but also covers the handling, storage and
use of our products. It is highly recommended that the installer review the instructions supplied by the pipe and fitting manufacturer.
#.-"/ WELD-ON solvent cements must never be used in a PVC system using or being tested by compressed air or gases; including air-over-water booster.
%0%+&%1+&+-2/
This product is available in ! pint (237 ml), pint (473 ml), quart (946 ml) and gallon (3.785 l) metal cans. For detailed information on
containers and applicators, see our current Price List.
)-%#(%$()'%#('*"$-+3+*%-+.#'&+)-+#!)/
UP
C
US
C
®
PW / DWV / SW
! Meets ASTM D 2564 Standard
! Meets SCAQMD Rule 1168/316A
! Compliant with LEED® (Leadership in Energy and Environmental Design). When using this WELD-ON Low
VOC product, credit can be claimed for LEED Green Building Rating System - Indoor Environmental Quality.
! Listed by NSF International for compliance with ASTM D 2564, NSF/ANSI Standard 14 and NSF/ANSI Stan-
dard 61 for use in potable water, drain, waste, vent and sewer applications.
! Meets CSA standards B137.3 and B181.2 for use in pressure and non-pressure potable water, drain, waste,
and vent applications.
! Listed by IAPMO for compliance with ASTM D 2564 and applicable sections of the latest edition of the Uniform
Plumbing Code®
),"*+3+*%-+.#)/
COLOR:
RESIN:
SPECIFIC GRAVITY:
BROOKFIELD VISCOSITY:
Gray
PVC
0.966 ± 0.04
Minimum 1,600 cP @ 73° ± 2°F (23° ± 1°C)
)4"&3'&+3"/
3 years in tightly sealed containers. The date code of manufacture is stamped on the bottom of the container. Stability of the product
is limited by the evaporation of the solvent when the container is opened. Evaporation of solvent will cause the cement to thicken
and reduce its effectiveness. Adding of thinners to change viscosity is not recommended and may significantly change the properties of the cement.
56%&+-2'%))6$%#*"/
WELD-ON 711 is carefully evaluated to assure that consistent high quality is maintained. Fourier transform infrared spectroscopy,
gas chromatography, and additional in depth testing ensures each batch is manufactured to exacting standards. A batch identification
code is stamped on each can and assures traceability of all materials and processes used in manufacturing this solvent cement.
)4+,,+#!/
378'.9:'&;<:8'=9>'%?7@:
Proper Shipping Name: Adhesive
Hazard Class: 3
Identification Number: UN 1133
Packing Group: II
Label Required: Flammable Liquid
378'&:AA'<B=9'.9:'&;<:8'
Proper Shipping Name: Consumer Commodity
Hazard Class: ORM-D
)%3"-2'%#('"#0+$.#C"#-%&',$"*%6-+.#)/
This product is flammable and considered a hazardous material. In conformance with the Federal Hazardous Substances Labeling
Act, the following hazards and precautions are given. Purchasers who repackage this product must also conform to all local,
state and federal labeling, safety and other regulations. VOC emissions do not exceed 510 grams per liter.
Copyright © 2009 by IPS Corporation
711-04-2009
!"#$%&'(%)*&%+%,-(.,"++"/,%0(1"23&(4"&+.5,0((
+"-(/%(4"&+.5,(6.(78",,38%!0(+"-(6&&6*"*%(796#(3&(%-%70
Keep out of reach of children. Do not take internally. Keep away from heat, spark, open flame and other sources of ignition. Vapors may ignite
explosively. Solvent cement vapors are heavier than air and may travel to source(s) of ignition at or near ground or lower level(s) and flash
back. Keep container closed when not in use. Store between 40°F (5°C) and 110°F (44°C). Avoid breathing of vapors. Use only in well-ventilated area. If confined or partially enclosed, use forced ventilation. When necessary, use local exhaust ventilation to remove harmful airborne
contaminants from employee breathing zone and to keep contaminates below 25 ppm TWA. Atmospheric levels must be maintained below
established exposure limits contained in Section II of the Material Safety Data Sheet (MSDS). If airborne concentrations exceed those limits,
use of a NIOSH approved organic vapor cartridge respirator with full face-piece is recommended. The effectiveness of an air-purifying respirator is limited. Use it only for a single short-term exposure. For emergency and other conditions where short-term exposure guidelines may be
exceeded, use an approved positive pressure self-contained breathing apparatus. Do not smoke, eat or drink while working with this product.
Avoid contact with skin, eyes and clothing. May cause eye injury. Protective equipment such as gloves, goggles and impervious apron should
be used. Carefully read Material Safety Data Sheet and follow all precautions. Do not use this product for other than intended use.
“SARA Title III Section 313 Supplier Notification”: This product contains toxic chemicals subject to the reporting requirements of Section 313
of the Emergency Planning and Community Right-to-Know Act (EPCRA) of 1986 and of 40CFR372. This information must be included in all
MSDS that are copied and distributed for this material.
!"#$%&'"()
Inhalation:
If overcome with vapors, remove to fresh air. If not breathing, give artificial respiration.
If breathing is difficult, give oxygen. Call physician.
Eye Contact:
Flush with plenty of water for 15 minutes and call a physician.
Skin Contact:
Wash skin with plenty of soap and water for at least 15 minutes.
If irritation develops, get medical attention.
Ingestion:
If swallowed, give 1 or 2 glasses of water or milk. Do not induce vomiting.
Contact physician or poison control center immediately.
$*+,"'-&*#+,'.%"/0)
Do not use a dry granular calcium hypochlorite as a disinfecting material for water purification in potable water piping systems. The introduction of granules or pellets of calcium hypochlorite with PVC and CPVC solvent cements and primers (including their vapors) may result in a
violent chemical reaction if a water solution is not used. It is advisable to purify lines by pumping chlorinated water into the piping system – this
solution will be nonvolatile. Furthermore, dry granular calcium hypochlorite should not be stored or used near solvent cements and primers.
"1*/#%'0%&0/%+)
This product is intended for use by skilled individuals at their own risk. These suggestions and data are based on information we believe to
be reliable. Installers should verify for themselves that they can make satisfactory joints under varying conditions. Toward this end, it is highly
desirable that they receive personal instruction from trained instructors or competent, experienced installers. Contact IPS® Corporation or
your supplier for additional information or instructions.
2'##'0%3)
IPS® Corporation (“IPS Corp.”) warrants that all new IPS Corp. products shall be of good quality and free from defects in material and workmanship for the shelf life as indicated on the product. If any IPS Corp. product becomes defective, or fails to conform to our written limited
warranty under normal use and storage conditions, then IPS Corp. will, without charge, replace the nonconforming product. However, this
limited warranty shall not extend to, nor shall IPS Corp. be responsible for, damages or loss resulting from accident, misuse, negligent use,
improper application, or incorporation of IPS Corp. products into other products. In addition, any repackaging of IPS Corp. products also shall
void the limited warranty. IPS Corp. shall not be responsible for, nor does this limited warranty extend to, consequential damage, or incidental
damage or expense, including without limitation, injury to persons or property or loss of use. Please refer to our standard IPS Corp. Limited
Warranty for additional provisions.
455 W. Victoria Street
Compton, CA 90220 U.S.A.
Tel: 310.898.3300
Fax: 310.898.3392
Customer Service: 800.888.8312
44456789:;759:<
500 Distribution Parkway
Collierville, TN 38017 U.S.A.
Tel: 901.853.5001
Fax: 901.853.5008
GHS SAFETY DATA SHEET
Date Revised: FEB 2010
WELD-ON® 711™ Low VOC PVC Plastic Pipe Cements
Supersedes:
SEP 2009
SECTION I - PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME:
WELD-ON® 711™ Low VOC PVC Plastic Pipe Cements
PRODUCT USE:
Low VOC Solvent Cement for PVC Plastic Pipe
MANUFACTURER:
SUPPLIER:
EMERGENCY: Transportation: Tel. 800.424.9300, 703.527.3887 CHEMTREC (International)
IPS Corporation
17109 South Main Street, Carson, CA 90248-3127
P.O. Box 379, Gardena, CA 90247-0379
Tel. 1-310-898-3300
Medical: Tel. 800.451.8346, 760.602.8703 3E Company (International)
SECTION 2 - HAZARDS IDENTIFICATION
GHS CLASSIFICATION:
Health
Acute Toxicity:
Category 4
Skin Irritation:
Category 3
Skin Sensitization:
NO
Eye:
Category 2B
Acute Toxicity:
Chronic Toxicity:
Physical
Environmental
None Known
None Known
GHS LABEL:
Flammable Liquid
Signal Word:
Danger
OR
WHMIS CLASSIFICATION:
Hazard Statements
Category 2
CLASS B, DIVISION 2
Precautionary Statements
H225: Highly flammable liquid and vapor
P210: Keep away from heat/sparks/open flames/hot surfaces – No smoking
H319: Causes serious eye irritation
P261: Avoid breathing dust/fume/gas/mist/vapors/spray
H332: Harmful if inhaled
P280: Wear protective gloves/protective clothing/eye protection/face protection
H335: May cause respiratory irritation
P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing
H336: May cause drowsiness or dizziness
P403+P233: Store in a well ventilated place. Keep container tightly closed
EUH019: May form explosive peroxides
P501: Dispose of contents/container in accordance with local regulation
SECTION 3 - COMPOSITION/INFORMATION ON INGREDIENTS
CAS#
Tetrahydrofuran (THF)
Methyl Ethyl Ketone (MEK)
Cyclohexanone
Acetone
EINECS #
109-99-9
78-93-3
108-94-1
67-64-1
203-726-8
201-159-0
203-631-1
200-662-2
REACH
Pre-registration Number
CONCENTRATION
% by Weight
05-2116297729-22-0000
05-2116297728-24-0000
05-2116297718-25-0000
05-2116297713-35-0000
40 - 50
5 - 15
9 - 18
3 - 11
All of the constituents of this adhesive product are listed on the TSCA inventory of chemical substances maintained by the US EPA, or are exempt from that listing.
* Indicates this chemical is subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right-to-Know Act of 1986 (40CFR372).
SECTION 4 - FIRST AID MEASURES
Contact with eyes:
Skin contact:
Inhalation:
Ingestion:
Flush eyes immediately with plenty of water for 15 minutes and seek medical advice immediately.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water. If irritation develops, seek medical advice.
Remove to fresh air. If breathing is stopped, give artificial respiration. If breathing is difficult, give oxygen. Seek medical advice.
Rinse mouth with water. Give 1 or 2 glasses of water or milk to dilute. Do not induce vomiting. Seek medical advice immediately.
SECTION 5 - FIREFIGHTING MEASURES
Suitable Extinguishing Media:
Unsuitable Extinguishing Media:
Exposure Hazards:
Combustion Products:
Protection for Firefighters:
Dry chemical powder, carbon dioxide gas, foam, Halon, water fog.
Water spray or stream.
Health
Inhalation and dermal contact
Flammability
Oxides of carbon, hydrogen chloride and smoke
Reactivity
Self-contained breathing apparatus or full-face positive pressure airline masks.
HMIS
2
3
0
NFPA
2
3
0
0-Minimal
1-Slight
2-Moderate
3-Serious
4-Severe
SECTION 6 - ACCIDENTAL RELEASE MEASURES
Personal precautions:
Keep away from heat, sparks and open flame.
Provide sufficient ventilation, use explosion-proof exhaust ventilation equipment or wear suitable respiratory protective equipment.
Prevent contact with skin or eyes (see section 8).
Environmental Precautions:
Prevent product or liquids contaminated with product from entering sewers, drains, soil or open water course.
Methods for Cleaning up:
Clean up with sand or other inert absorbent material. Transfer to a closable steel vessel.
Materials not to be used for clean up:
Aluminum or plastic containers
SECTION 7 - HANDLING AND STORAGE
Handling: Avoid breathing of vapor, avoid contact with eyes, skin and clothing.
Keep away from ignition sources, use only electrically grounded handling equipment and ensure adequate ventilation/fume exhaust hoods.
Do not eat, drink or smoke while handling.
Storage: Store in ventilated room or shade below 44°C (110°F) and away from direct sunlight.
Keep away from ignition sources and incompatible materials: caustics, ammonia, inorganic acids, chlorinated compounds, strong oxidizers and isocyanates.
Follow all precautionary information on container label, product bulletins and solvent cementing literature.
SECTION 8 - PRECAUTIONS TO CONTROL EXPOSURE / PERSONAL PROTECTION
EXPOSURE LIMITS:
Component
Tetrahydrofuran (THF)
Methyl Ethyl Ketone (MEK)
Cyclohexanone
Acetone
ACGIH TLV
ACGIH STEL
50 ppm
200 ppm
20 ppm
500 ppm
100 ppm
300 ppm
50 ppm
750 ppm
OSHA PEL OSHA STEL:
200 ppm
200 ppm
50 ppm
1000 ppm
Engineering Controls: Use local exhaust as needed.
Monitoring:
Maintain breathing zone airborne concentrations below exposure limits.
Personal Protective Equipment (PPE):
Eye Protection:
Avoid contact with eyes, wear splash-proof chemical goggles, face shield, safety glasses (spectacles) with brow guards and side shields,
etc. as may be appropriate for the exposure.
Skin Protection:
Prevent contact with the skin as much as possible. Butyl rubber gloves should be used for frequent immersion.
Use of solvent-resistant gloves or solvent-resistant barrier cream should provide adequate protection when normal adhesive application
practices and procedures are used for making structural bonds.
Respiratory Protection: Prevent inhalation of the solvents. Use in a well-ventilated room. Open doors and/or windows to ensure airflow and air changes. Use local
exhaust ventilation to remove airborne contaminants from employee breathing zone and to keep contaminants below levels listed above.
With normal use, the Exposure Limit Value will not usually be reached. When limits approached, use respiratory protection equipment.
Filename: W-O711LoVoc_2-10.xls
Page 1 of 2
2/23/2010 3:29 PM
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES
Appearance:
Gray, heavy syrupy liquid
Odor:
Ketone
Odor Threshold:
0.88 ppm (Cyclohexanone)
pH:
Not Applicable
Melting/Freezing Point:
-108.5°C (-163.3°F) Based on first melting component: THF
Boiling Range:
56°C (133°F) to 156°C (313°F)
Boiling Point:
56°C (133°F) Based on first boiling component: Acetone
Evaporation Rate:
> 1.0 (BUAC = 1)
Flash Point:
-20°C (-4°F) TCC based on Acetone
Flammability:
Category 2
Specific Gravity:
0.966 @23°C ( 73°F)
Flammability Limits:
LEL: 1.1% based on Cyclohexanone
Solubility:
Solvent portion soluble in water. Resin portion separates out.
UEL: 12.8% based on Acetone
Partition Coefficient n-octanol/water:
Not Available
Vapor Pressure:
190 mm Hg @ 20°C (68°F) Acetone
Auto-ignition Temperature:
321°C (610°F) based on THF
Vapor Density:
>2.0 (Air = 1)
Decomposition Temperature:
Not Applicable
Other Data: Viscosity:
Heavy bodied
When applied as directed, per SCAQMD Rule 1168, Test Method 316A,VOC content is: < 510 g/l.
VOC Content:
SECTION 10 - STABILITY AND REACTIVITY
Stability:
Hazardous decomposition products:
Conditions to avoid:
Incompatible Materials:
Stable
None in normal use. When forced to burn, this product gives off oxides of carbon, hydrogen chloride and smoke.
Keep away from heat, sparks, open flame and other ignition sources.
Oxidizers, strong acids and bases, amines, ammonia
SECTION 11 - TOXICOLOGICAL INFORMATION
Likely Routes of Exposure:
Inhalation, Eye and Skin Contact
Acute symptoms and effects:
Inhalation:
Severe overexposure may result in nausea, dizziness, headache. Can cause drowsiness, irritation of eyes and nasal passages.
Eye Contact:
Vapors slightly uncomfortable. Overexposure may result in severe eye injury with corneal or conjunctival inflammation on contact with the liquid.
Skin Contact:
Liquid contact may remove natural skin oils resulting in skin irritation. Dermatitis may occur with prolonged contact.
Ingestion:
May cause nausea, vomiting, diarrhea and mental sluggishness.
Chronic (long-term) effects:
None known to humans
LD50
LC50
Toxicity:
Inhalation 3 hrs. 21,000 mg/m3 (rat)
Tetrahydrofuran (THF)
Oral: 2842 mg/kg (rat)
Inhalation 8 hrs. 23,500 mg/m3 (rat)
Methyl Ethyl Ketone (MEK)
Oral: 2737 mg/kg (rat), Dermal: 6480 mg/kg (rabbit)
Cyclohexanone
Oral: 1535 mg/kg (rat), Dermal: 948 mg/kg (rabbit)
Inhalation 4 hrs. 8,000 PPM (rat)
Inhalation 50,100 mg/m3 (rat)
Acetone
Oral: 5800 mg/kg (rat)
Reproductive Effects
Not Established
Teratogenicity
Not Established
Mutagenicity
Not Established
Embryotoxicity
Not Established
Sensitization to Product
Not Established
Synergistic Products
Not Established
SECTION 12 - ECOLOGICAL INFORMATION
Ecotoxicity:
Mobility:
Degradability:
Bioaccumulation:
None Known
In normal use, emission of volatile organic compounds (VOC's) to the air takes place, typically at a rate of < 510 g/l.
Biodegradable
Minimal to none.
SECTION 13 - WASTE DISPOSAL CONSIDERATIONS
Follow local and national regulations. Consult disposal expert.
SECTION 14 - TRANSPORT INFORMATION
Proper Shipping Name:
Hazard Class:
Secondary Risk:
Identification Number:
Packing Group:
Label Required:
Marine Pollutant:
Adhesives
3
EXCEPTION for Ground Shipping
None
DOT Limited Quantity: Up to 5L per inner packaging, 30 kg gross weight per package.
UN 1133
Consumer Commodity: Depending on packaging, these quantities may qualify under DOT as "ORM-D" .
PG II
Class 3 Flammable Liquid
TDG INFORMATION
NO
TDG CLASS:
FLAMMABLE LIQUID 3
SHIPPING NAME:
ADHESIVES
UN NUMBER/PACKING GROUP:
UN 1133, PG II
SECTION 15 - REGULATORY INFORMATION
Precautionary Label Information: Highly Flammable, Irritant
Symbols:
F, Xi
Risk Phrases:
R11: Highly flammable.
R20-Harmful by inhalation.
R36/37: Irritating to eyes and respiratory system.
Safety Phrases:
S9: Keep container in a well-ventilated place.
S16: Keep away from sources of ignition - No smoking.
S25: Avoid contact with eyes.
Ingredient Listings: USA TSCA, Europe EINECS, Canada DSL, Australia
AICS, Korea ECL/TCCL, Japan MITI (ENCS)
R66: Repeated exposure may cause skin dryness or cracking
R67: Vapors may cause drowsiness and dizziness
S26: In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
S33: Take precautionary measures against static discharges.
S46: If swallowed, seek medical advise immediately and show this container or label.
SECTION 16 - OTHER INFORMATION
Specification Information:
Department issuing data sheet:
E-mail address:
IPS, Safety Health & Environmental Affairs
<[email protected]>
Training necessary:
Reissue date / reason for reissue:
Intended Use of Product:
Yes, training in practices and procedures contained in product literature.
2/23/10 / Updated GHS Standard Format
Solvent Cement for PVC Plastic Pipe
All ingredients are compliant with the requirements of the European
Directive on RoHS (Restriction of Hazardous Substances).
This product is intended for use by skilled individuals at their own risk. The information contained herein is based on data considered accurate based on current state of
knowledge and experience. However, no warranty is expressed or implied regarding the accuracy of this data or the results to be obtained from the use thereof.
Filename: W-O711LoVoc_2-10.xls
Page 2 of 2
2/23/2010 3:29 PM