Energy Management
Transcription
Energy Management
Energy Management Energy Meter Type EM10 DIN • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Energy meter • Energy readout: 5+1 DGT • Energy measurements: total kWh • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply • Dimensions: 1-DIN module • Protection degree (front): IP40 • 1 pulse output on request • Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003), see option “P” below • Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003), see option “PF” below. Product Description How to order EM10 DIN AV8 1 X O1 P One-phase energy meter with LCD data displaying; indicated for active energy metering. Housing for DINrail mounting, IP40 (front) protection degree. Direct connection up to 32A. Moreover the meter can be provided with pulse output proportional to the active energy being measured. Model Range code System Power supply Output Option Range code System Power supply Option AV7: 1: X: P: Type Selection AV8: 120VLN AC - 5(32)A (**) (direct connection) 230VLN AC - 5(32)A (*) (direct connection) (*) as standard. (**) on request, the range is available but not in compliance with the MID 1-phase Output O1: Pulse type (open collector output) (*) Self power supply (from 48 to 62Hz). The instrument works on the range from -20% to +20% of the measuring nominal input voltage. Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003) (*) PF: Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003) (**) X(**): AV7 range is not in compliance with the MID directive Input specifications Rated inputs Current range (by shunt) Voltage range System: 1 AV7 and AV8: 5(32)A AV7: 120 VLN AC (The option “P” is not available) AV8: 230 VLL AC Accuracy (Display) (@25°C ±5°C, R.H. ≤60%, 48 to 62Hz) Ib: 5A, Imax: 32A; AV7 model Un: 120VLN (-20% +20%) AV8 model Ib: 5A, Imax: 32A; Un: 230VLN (-20% +20%) Specifications are subject to change without notice Active energy Reference values Start up current: Energy additional errors Influence quantities Temperature drift Sampling rate EM10DIN DS 280409 Class 1 according to EN62053-21 and Class B according to EN50470-3. MID (Annex MI-003) Class B. Ib: 5A, Imax: 32A, 0.1 Ib: 0.5A 20mA According to EN62053-21, ≤200ppm/°C 4096 samples/s @ 50Hz 4096 samples/s @ 60Hz 1 EM10 DIN Wiring diagram and open collector output (O1) 1-phase connection Fig. 1 Fig. 2 1 open collector output VDC VDC EM10-DIN VDC Reference NOTE: The 3 and 4 terminals, in the instrument, are wired together GND Reference The load resistances (RC) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. Frontal panel description and tamper proof 3 4 1 2 4 3 1. Display LCD-type with energy indication. 2. LED Red LED to show the consumed energy. 3. Tamper proof The instrument can be sealed in two points: upper cover and lower cover. 4. Protection covers for tamper proof The “tamper proof” kit is available with the “P” option. Dimensions and panel cut-out 45.5mm 45mm 90mm 18mm 44mm 67.5mm 4 17.5 +0.5/-0mm Specifications are subject to change without notice EM10DIN DS 280409 Energy Management Energy Analyzer Type EM11 DIN • Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003), see option “PF” below. • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy analyzer • Instantaneous variables readout: 4 DGT • Energies readout: 5+1 DGT • Instantaneous variables: V, A, W, Wdmd, Wdmd max, var, PF, Hz • Single phase variables: VLL, VLN, A, VA, W, var, PF • Energy measurements: total kWh and kvarh • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply • Dimensions: 1-DIN module • Protection degree (front): IP40 • 1 pulse output on request • 1 alarm output on request • Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003), see option “P” below. Product Description How to order EM11 DIN AV8 1 X O1 X One-phase energy analyzer with built-in configuration push button and LCD data displaying; particularly indicated for active and reactive energy metering and for cost allocation. Housing for DIN-rail mounting, IP40 (front) protection degree. Direct connection up to 32A. Moreover the meter can be provided with either pulse output proportional to the active energy being measured or alarm control on the available instantaneous variables. Model Range code System Power supply Output Option Range code System Power supply Output AV7: 1: X: XX: O1: Type Selection AV8: 120VLN AC - 5(32)A (***) (direct connection) 230VLN AC - 5(32)A (*) (direct connection) (*) as standard. (**) on request. The meter is supplied without front pushbutton, the scrolling of the variables is made automatically. 1-phase Option X(***): AV7 range is not in compliance with the MID directive P: Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003) (**) PF: Certified according to MID Directive, Annex "B" + Anex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003) (**) Specifications are subject to change without notice Self power supply (from 48 to 62Hz). The instrument works on the range from -20% to +20% of the measuring input nominal voltage. EM11DIN DS ENG 280409 R1: None (**) Pulse type (open collector output) (*) Alarm type (relay out-put) (*) Output not available in case of “P” option 1 EM11 DIN Wiring diagrams and open collector output (O1) 1-phase connection Fig. 1 1 open collector output VDC Fig. 2 VDC VDC Reference NOTE: The 3 and 4 terminals, in the instrument, are wired together GND Reference The load resistances (RC) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. Frontal panel description 3 2 1 1. Push button To program the configuration parameters and the display of the variables. Not available in case of “P” option. 2. LED Red LED to show the consumed energy. 3. Display LCD-type with alphanumeric indication to: - display configuration parameters; - display all the measured variables. Dimensions and panel cut-out 45.5mm 45mm 90mm 18mm 44mm 67.5mm 6 17.5 +0.5/-0mm Specifications are subject to change without notice EM11DIN DS ENG 280409 Energy Management Energy Meter Type EM23 DIN • Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003), see option “PF” below. • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy meter • Instantaneous variables readout: 3 DGT • Energies readout: 6+1 DGT • System variables: W, var, Phase-sequence. • Single phase variables: A • Energy measurements: total kWh and kvarh • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply • 1 pulsating output • Dimensions: 4-DIN modules • Protection degree (front): IP50 • Easy connections management • Certified according to MID Directive, “Annex B”. “Type Examination” relevant to active electrical energy meters (see Annex MI-003), see option “P” below Product Description How to order EM23 DIN AV9 3 X O1 P Three-phase energy meter with built-in configuration joystick and LCD data displaying; particularly indicated for active and reactive energy metering and for cost allocation. Housing for DINrail mounting with IP50 (front) protection degree. Direct connection up to 65A. Moreover the meter is provided with one pulsating output proportional to the active energy being measured. Model Range code System Power supply Output Option Range codes System Output AV2: 3: O1: Type Selection AV9: 400VLLAC 10(65)A (direct connection) (**) VLN : 113V to 265VLN VLL : 196V to 460VLL 400VLL AC - 10(65)A (direct connection) (*) VLN : 184V to 276VLN VLL : 318V to 480VLL Balanced and unbalanced load: 3-phase, 4-wire; 3-phase, 3-wire; PF: Specifications are subject to change without notice Open collector type (single pulse output) X: Self power supply -15% +20% of the rated measuring input voltage, 45 to 65 Hz Options X: P: (*) as standard. (**) on request. Power supply none Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003) (*) Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003) (**) EM23DIN DS ENG 280509 1 EM23 DIN Open collector output wiring diagrams Open Collector Open Collector VDC VDC GND reference The load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. VDC reference Front panel description 1 3 2 1. Joystick To scroll the variables on the display. 2. LED Red LED blinking proportional to the energy being measured. 3. Display LCD-type with alphanumeric indications to display all the measured variables. 4. Connections Screw terminal blocks for instrument wiring. 4 Dimensions 6 Specifications are subject to change without notice EM23DIN DS ENG 280509 Energy Management Energy Analyzer Type EM24 DIN • Dupline communication capability (DP option) • Application adaptable display and programming procedure (Easyprog function) • Easy connections management • Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003), see option “P” below • Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003), see option “PF” below. • Class 1 (kWh) according to EN62053-21 • Class B (kWh) according to EN50470-3 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy analyzer • Instantaneous variables readout: 4 DGT • Energies/gas/water readout: 7+1 DGT • System variables: VLL, VLN, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence. • Single phase variables: VLL, VLN, A, VA, W, var, PF • Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs; single phase measurements • Gas, cold water, hot water, kWh remote heating measurements • Hour counter (6+2 DGT) • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply (AV0-AV2-AV9 inputs) • Auxiliary power supply (AV5-AV6 inputs) • 3 digital inputs for tariff selection, DMD synch or gas/ water (hot-cold) and remote heating metering (on request) • 2 digital outputs for pulses or for alarms or as a mix of them (on request) • Dimensions: 4-DIN modules • Protection degree (front): IP50 • RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility Product Description How to order EM24 DIN AV5 3 X O2 X Three-phase energy analyzer with built-in configuration joystick and LCD data displaying; particularly indicated for active and reactive energy metering and for cost allocation. Housing for DIN-rail mounting with IP50 (front) protection degree. Direct connection up to 65A and by means of external current and potential transformers. Moreover the meter can be provided with digital outputs that can be either for pulse proportional to the active and reactive energy being measured or for alarm outputs. In alternative the RS485 communication port and 3 digital inputs or Dupline port and 3 digital inputs are available as an option. Model Range code System Power supply Inputs/Outputs Option Range codes System Inputs/Outputs Power supply AV5: 1: XX: O2: X: Type Selection AV6: AV0: AV2: AV9: 400VLL AC - 1/5 (10)A (CT connection) (*) VLN : 160 V to 480VLN VLL : 277 V to 830VLL 208VLL AC - 1/5(10)A (VT/PT and CT connections) (*) VLN : 40V to 144VLN VLL : 70V to 250VLL 208VLL AC -10(65)A (direct connection) (**) VLN : 96V to 144VLN VLL : 166V to 250VLL 400VLLAC 10(65)A (direct connection) (**) VLN : 113V to 265VLN VLL : 196V to 460VLL 400VLL AC - 10(65)A (direct connection) (*) VLN : 184V to 276VLN VLL : 318V to 480VLL 3: 1-phase, 2-wire; 3-phase, 3-wire, 3-phase, 4-wire balanced load (**) balanced and unbalanced load: 3-phase, 4-wire; 3-phase, 3-wire; 2-phase, 3-wire; 1-phase, 2-wire (*) R2: XS: IS: Options DP: P: PF: X: Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003) (*) Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003) (**) none Specifications are subject to change without notice none (*) dual open collector type (dual pulse or one pulse + one alarm or dual alarm) (*) dual relay type (functions as per “O2”) (**)(°) RS485 port (**) 3 digital inputs for tariff selection or Gas/ water/ remote heating metering plus RS485 port (*) Dupline port plus 3 digital inputs for Gas / water / remote heating metering (°°) Self power supply (See “Power supply specifications”) (*) L: 18 to 60VAC/DC (48 to 62Hz) (**) D: 115/230 VAC (48 to 62Hz) (*) Note: “L” and “D” power supplies only for AV5 and AV6 inputs; “X” power supply only for AV0, AV2 and AV9 inputs. (*) as standard. (**) on request. (°) not available if the range code is “AV2”. (°°) available if the range code is either “AV2” or “AV5”. EM24 DIN DS 280409 1 EM24 DIN Digitala inputs, RS485 and Dupline ports wiring diagrams Digital Inputs and RS485 RS485 port Digital Inputs and Dupline Dupline port Front panel description 1 3 2 4 5 1. Joystick To program the configuration parameters and scroll the variables on the display. 2. LED Red LED blinking proportional to the energy being measured. 3. Display LCD-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 4. Selector To select the desired display pages and to lock the programming. 5. Connections Screw terminal blocks for instrument wiring. Dimensions 14 Specifications are subject to change without notice EM24 DIN DS 280409 Energy Management Energy Meter Type EM21 72D • Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003), see option “P” below • Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003), see option “PF” below. • Class B (kWh) according to EN50470-3 • Class 1 (kWh) according to EN62053-21 • Class 2 (kvarh) according to EN62053-23 • Accuracy ±0.5 RDG (current/voltage) • Energy meter • Instantaneous variables readout: 3 DGT • Energies readout: 6+1 DGT • System variables: W, var, PF, Hz, Phase-sequence. • Single phase variables: VLL, VLN, A, PF • Energy measurements: total kWh and kvarh • TRMS measurements of distorted sine waves (voltages/currents) • Self power supply • Dimensions: 4-DIN modules and 72x72mm • Protection degree (front): IP50 • Application adaptable display and programming procedure (Easyprog function) • Easy connections management • Detachable display • Multi-use housing: for both DIN-rail and panel mounting applications Product Description How to order EM21 72D AV5 3 X O X X Three-phase energy meter with removable front LCD display unit. The same unit can be used either as a DIN-rail mounting or a panel mounting energy meter. This general purpose threephase energy meter is suitable for both active and reactive energy metering for cost allocation but also for main electrical parameter measurement and retransmission (transducer function). Housing for DINrail mounting with IP50 (front) protection degree. Current measurements carried out by means of external current transformers and voltage measurements carried out either by means of direct connection or by means of potential transformers. EM21-72D is provided, as standard, with a pulsating output for active energy retransmission. In addition a 2-wire RS485 communication port is available as an option. Model Range code System Power supply Output 1 Output 2 Option Range codes System Power supply Options AV5 (*): 400VLL AC, 5(6)A or 1(6)A (***) (CT connection) AV6 (**):120VLN/230VLL AC 5(6)A or 1(6)A (***) (VT/PT and CT connections) 3 (*): X (*): Self power supply from 18V to 260VAC VLN, 45 to 65 Hz (connection VL1-N) X (*): P: Type Selection balanced and unbalanced load: 3-phase, 4-wire; 3-phase, 3-wire; 2-phase, 3-wire; 1-phase, 2-wire PF: Output 2 Output 1 X (*): None S (**): RS485 port O (*): Single static output (opto-mosfet) Specifications are subject to change without notice (*) as standard. (**) on request. (***) the range 1(6)A is available but not in compliance with the EN50470-3 standard. EM2172D DS ENG 120509 None Certified according to MID Directive, Annex "B" "Type examination" relevant to active electrical energy meters (see Annex MI-003) (*) Certified according to MID Directive, Annex "B" + Annex "F" for legal metrology relevant to active electrical energy meters (see Annex MI-003) (**) 1 EM21 72D Front panel description 5 4 1 2 3 1 4 1. Keypad To program the configuration parameters and scroll the variables on the display. 2. Pulse output LED Red LED blinking proportional to the energy being measured. 3. Display LCD-type with alphanumeric indications to display all the measured variables. 4. Connections Screw terminal blocks for instrument wiring. 5. Green LED Lit when power supply is available Dimensions (DIN configuration) Dimensions and panel cut out (72x72 panel mounting configuration) 68x68mm -0 +0.7mm 10 Specifications are subject to change without notice EM2172D DS ENG 120509 Energy Management Power Analyzer Type WM14-96 “Basic Version” • Optional dual pulse output • Alarms (visual only) VLN, An • Optional galvanically insulated measuring inputs • Class 1 (active energy) • Class 2 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) • Power analyzer • Display of instantaneous variables: 3x3 digit • Display of energies: 8+1 digit • System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz • Amax, Admd max, Wdmd max indication • Energy measurements: kWh and kvarh • Hour counter (5+2 DGT) • TRMS meas. of distorted sine waves (voltages/currents) • Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC • Protection degree (front): IP65 • Front dimensions: 96x96mm • Optional RS422/485 serial port Product Description How to order 3-phase power analyzer with built-in programming keypad. Particularly recommended for displaying the main electrical variables. Housing for panel mounting, Model Range code System Power supply Option (front) protection degree IP65, and optional RS485 serial port or dual pulse output. Parameters programmable by means of CptBSoft. How to order CptBSoft CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables. Type Selection Range codes System Power supply AV5: 3: A: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A WM14-96 AV5 3 D PGX 1-2-3-phase, balanced/unbalanced load,with or without neutral B: C: D: 3: 24VAC -15+10%, 50-60Hz 48VAC -15+10%, 50-60Hz 115VAC -15+10%, 50-60Hz 230VAC -15+10%, 50-60Hz 18 to 60VDC (not available in case of SG or PG options) Options X: S: SG: PG: None RS485 port RS485+galvanic insulated measurig inputs Dual pulse output + galvanically insulated measuring inputs. Input specifications Rated inputs Current “X-S options” Current “SG-PG options” Voltage Accuracy (display, RS485) (@25°C ±5°C, R.H. ≤60%) Current Neutral current Phase-phase voltage Phase-neutral voltage Active and Apparent power, Reactive power 3 (non insulated each other) 3 (insulated each other) 4 with CT=1 and VT=1 AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL 0.25 to 6A: ±(0.5% FS +1DGT) 0.03A to 0.25A: ±(0.5%FS+7DGT) 0.25 to 6A: ±(1.5% FS +1DGT) 0.09A to 0.25A: ±(0.5%FS+7DGT) ±(1.5% FS +1 DGT) ±(0.5% FS + 1 DGT) 0.25 to 6A: ±(1% FS +1DGT); 0.03A to 0.25A: ±(1% FS +5DGT) 0.25 to 6A: ±(2% FS +1DGT); Specifications are subject to change without notice Active energy “X-S option” Reactive energy “X-S option” Active energy “SG-PG opt.” Reactive energy “SG-PG opt.” Frequency Additional errors Humidity Temperature drift Sampling rate Display refresh time Display Type Read-out for instant. var. Read-out for energies WM14 96 DS ENG 200508 0.03A to 0.25A: ±(2% FS +5DGT) Class 2 (start up “I”: 30mA) Class 3 (start up “I”: 30mA) Class 1 (start up “I”: 30mA) Class 2 (start up “I”: 30mA) ±0.1Hz (48 to 62Hz) ≤0.3% FS, 60% to 90% RH ≤ 200ppm/°C 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 14mm 3x3 DGT 3+3+3 DGT (Max indication: 999 999 99.9) 1 WM14-96 RS485 port connections [c] GND 9 T 10 T 10 RS485 RS232 RX+ 11 RX+ 11 TX+ RX- 12 RX- 12 TX- TX+ 13 TX+ 13 RX+ TX- 14 TX- 14 RX- [a] GND [b] 9 Fig. 8 GND PC Pulse 2 9 Pulse 1 [b] [a] GND Dual pulse output connections 4-wire connection [c] GND 9 1 GND T 10 T 10 RS485 RS232 RX+ 11 RX+ 11 TX+ RX- 12 RX- 12 TX- TX+ 13 TX+ 13 RX+ TX- 14 TX- 14 RX- 1 PC 2-wire connection N + L - 3 3 11 6 12 7 1314 8 9 Fig. 7: a-Last instrument; b-1...n Instrument c-RS485/232 serial converter Front Panel Description 1. Key-pad To program the configuration parameters and the display of the variables. 2 S Key to enter programming and confirm selections; ▲ ▲ Keys to: - programme values; - select functions; - display measuring pages. 2. Display LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 1 96mm 96mm Dimensions and Panel Cut-out 91mm 96mm 61.4mm Specifications are subject to change without notice 15.4mm WM14 96 DS ENG 200508 7 Energy Management Multifunction meter Type WM10 DIN • Accuracy ±0.5% RDG (current/voltage) • Multifunction meter • Instantaneous variables readout: 3 DGT • System variables: W, var, PF, Hz and phase-sequence. • Single phase variables: A, VL-N, VL-L, W, var • TRMS measurements of distorted sine waves (voltages/currents) • Direct connection up to 65A • Self power supply • Dimensions: 4-DIN modules • Protection degree (front): IP50 • Easy installation: no parameters programming needed. Product Description How to order WM10 DIN AV9 3 X XX X Three-phase multifunction meter with built-in joystick and LCD data displaying. Housing for DIN-rail mount- ing with IP50 (front) protection degree. Direct connection up to 65A. No set-up needed. Model Range code System Power supply Output Option Range codes System Output AV9: 3: XX: Type Selection 400VLL AC - 10(65)A (Direct connection) balanced and unbalanced load: 3-phase, 4-wire; 3-phase, 4-wire Power supply none X: Self power supply -15% +20% of the rated measuring input voltage, 45 to 65 Hz Options X: none Specifications are subject to change without notice WM10DINDS 061207 1 WM10 DIN Wiring diagrams 3-ph, 4-wire, unbal./bal. load Fig.1 3-ph, 3-wire, unbal./bal. load Fig. 2 65A inputs self power supply Front panel description 3 1 2 1. Joystick To scroll the variables on the display. 2. Display LCD-type with alphanumeric indications to display all the measured variables. 3. Connections Screw terminal blocks for instrument wiring. 3 Dimensions Specifications are subject to change without notice WM10DINDS 061207 5 Energy Management Multifunction indicator Type WM12-96 • Accuracy ±0.5 F.S. (current/voltage) • Multifunction indicator • Display of instantaneous variables: 3x3 digit • Variable system and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Hz • Amax, Wdmd max indication • TRMS meas. of distorted sine waves (voltages/currents) • Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC • Protection degree (front): IP65 • Front dimensions: 96x96mm • Optional RS422/485 serial output • Alarms (visual only) VLN, An Product Description How to order 3-phase multifunction power indicator with built-in programming key-pad. Particularly recommended for displaying the main electrical variables. Housing for panel mounting, (front) protection degree IP65 as standard, and optional RS485 serial output. Model Range code System Power supply Option Range codes System Power supply Options AV5: 3: A: X: S: WM12-96 AV5 3 D XX Type Selection 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A 1-2-3-phase, unbalanced load, with or without neutral B: C: D: 3: 24VAC -15+10%, 50-60Hz 48VAC -15+10%, 50-60Hz 115VAC -15+10%, 50-60Hz 230VAC -15+10%, 50-60Hz 18 to 60VDC None RS485 output Input specifications Rated inputs Current Voltage Accuracy (display, RS485) (@25°C ±5°C, R.H. ≤60%) Current Neutral current Phase-phase voltage Phase-neutral voltage Active and Apparent power, Power factor Reactive power Frequency Additional errors Humidity Temperature drift Sampling rate 3 (shunt) 4 with CT=1 and VT=1 AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL 0.25 to 6A: ±(0.5% FS +1DGT) 0.03A to 0.25A: ±7DGT 0.25 to 6A: ±(1.5% FS +1DGT) 0.09A to 0.25A: ±7DGT ±(1.5% FS +1 DGT) ±(0.5% FS + 1 DGT) 0.25 to 6A: ±(1% FS +1DGT); 0.03A to 0.25A: ±(1% FS +5DGT) 0.25 to 6A: ±(2% FS +1DGT); 0.03A to 0.25A: ±(2% FS +5DGT) ±0.1%Hz (48 to 62Hz) Display refresh time Display Type Read-out for the instant. var. Measurements Coupling type Crest factor Input impedance 380/660VL-L (AV5) 120/208VL-L (AV6) Current Frequency Overload protection Continuous voltage/current For 500ms: voltage/current 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 14mm 3x3 DGT Current, voltage, power, power factor, frequency TRMS measurement of distorted waves. Direct < 3, max 10A peak 1 MΩ ±5% 453 KΩ ±5% ≤ 0.02Ω 48 to 62 Hz 1.2 F.S. 2 Un/36A ≤0.3% FS, 60% to 90% RH ≤ 200ppm/°C Specifications are subject to change without notice WM12-96 DS061107 1 WM12-96 Front Panel Description 1. Key-pad To program the configuration parameters and the display of the variables. 2 S Key to enter programming and confirm selections; ▲ ▲ Keys to: - programme values; - select functions; - display measuring pages. 1 2. Display LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 96mm 96mm Dimensions and Panel Cut-out 15.4mm 96mm 61.4mm 91mm Specifications are subject to change without notice WM12-96 DS061107 5 Accessories AC Current Transformer (max 23mm φ cable) Type CTD-1X • Cable and bus-bar type current transformer • 0.5 class, currents from 50 to 300 A • Removable DIN-rail mounting holder • Removable panel fixing clips • 2 cable/bus-bar isolated fixing screws • Double screw terminals (up to 8-wire connections) • Sealable terminal block covers Product Description Ordering Key CTD-1X 100 5A XXX Cable/Bus-bar type current transformer with DIN-rail/busbar and panel mounting facility. Model Primary current Secondary current Option Rated primary currents from 50 A to 300 A. Optional fixing kit: CTD-kit Type Selection Primary current Secondary current Option From 50 to 300A (Refer to Range Table) 1A 5A XXX: XTX: none tropicalization Input Specifications Operating frequency Max. system voltage Rated insulation level Insulation class Short-time current rating Ith Idyn Extended current rating Security factor (FS) 48 to 62 Hz 0.72 kV 3 kV/1 min. @ 50 Hz E (max 75°C) Typical 100 In /1 s 2.5 Ith The short-time thermal current Ith is anyway limited by the cable/bus-bar size 120% ≤ 5 (Class: 0.5, 1 and 3) Special features Working temperature Storage temperature Approvals Connection Cable cross section area General Specifications Standards Housing Mounting Standard accessories Optional accessories According to EN60044-1 ABS, self-extinguishing: UL 94 V-0 DIN-rail bus-bar and panel mounting Two terminal block screws. Two sealable terminal block covers. Two panel mounting fixing clips. One DIN rail adapter. Extended fixing kit CTD-kit: Six cable/bus-bar fixing screws. Six plastic caps for cable/bus-bar fixing screws. Specifications are subject to change without notice Protection degree Cable diameter Bus-bar size Weight Two panel mounting fixing clips. 1 A secondary current, Tropicalization -25°C to +60°C (-13°F to 140°F) (R.H. < 90% non condensing @ 40°C) -30°C to +70°C (-22°F to 158°F) (R.H. < 90% non condensing @ 40°C) CE Screw type From 1.5 to 6 mm2 Min/Max screws tightening torque relevant to terminal block screws: From 1 to 2 Nm Max screws tightening torque relevant to the cable/bus-bar fixing screws: 0,3 Nm IP00 IP20 (with sealable terminal block covers + wire termi nals) Max. 23 mm Max. 20x5 mm From 150 to 200 g Output Specifications Rated secondary current CTD-1X DS ENG 020708 5 A or 1 A 1 CTD-1X Range Table Model CTD-1X from 50A to 100A Primary Current A 50 60 70 75 80 100 Model CTD-1X from 120A to 300A Primary Current A 120 125 150 160 200 250 300 Burden (VA) CL 0.5 CL 1 1 1 1.5 1.25 1.5 1.75 1 1.25 1.5 CL 3 1.25 1.25 1.75 1.75 2 2.25 Burden (VA) CL 0.5 1.75 2 2.25 2.5 3 4.5 5 CL 1 2 2.25 2.5 2.75 3.25 4.75 5.5 CL 3 2.5 2.75 3 3.25 3.75 5.25 6 Benefits 1 2 3 4 5 6 7 8 9 10 Dimensions (mm) 44 30 3,3 27 Wiring Diagram S1 83,6 φ2 65,2 • Easy and quick mounting either on a panel or on a DIN-rail (see figure 1-2). • Protection of screw terminals using specific sealable covers to assure always the best safety (see figure 3). • Bridging of current transformer output without changing the connection of the secondary, so to avoid any output overvoltage during either the maintenance or the installation procedure (see figure 4). • Easy output and earth connection (see fig. 5). • Screw terminals compatible with any kind of wire terminals (see figure 6-7-8-9). • Multiple screws provided with insulation caps to grant a strong and reliable fixing of the current transformer to the bus-bar (see figure 10). S2 22 44 L P1 P2 69,2 46 N 2 Specifications are subject to change without notice CTD-1X DS ENG 020708 Accessories AC Split-Core Current Transformer Type CTD-5S ( max 26x32 mm) • Bus-bar type split core current transformer • Class 1 accuracy • Currents from 100 A to 400 A • Up to 6 Bus-bar isolated fixing screws • Double screw terminals (up to 8-wire connections) • Sealable terminal block covers • Sealable fixing split-core screws Product Description Ordering Key CTD-5S 400 5A XXX Split-core current transformer with bus-bar mountng facility. Model Primary current Secondary current Option Rated primary currents from 100 A to 400 A. Type Selection Primary current Secondary current Option From 100A to 400A (Refer to the Range Table) 1A (on request) 5A XXX: XTX: none tropicalization (on request) Input Specifications Operating frequency Max. system voltage Rated insulation level Insulation class Short-time current rating Ith Idyn Extended current rating Security factor (FS) 48 to 62 Hz 0.72 kV 3 kV/1 min. @ 50 Hz E (max 75°C) Typical 100 In /1 s 2.5 Ith The short-time thermal current Ith is anyway limited by the cable/bus-bar size 120% ≤ 5 (Class: 1 and 3) General Specifications Standards Housing Mounting Standard accessories Special features Storage temperature Approvals Connection Cable cross section area Protection degree According to EN60044-1 ABS, self-extinguishing: UL 94 V-0 Bus-bar mounting Two terminal block screws. Six cable/bus-bar fixing screws. Six plastic caps for cable/bus-bar fixing screws. Two sealable terminal block covers. 1 A secondary current, Tropicalization Specifications are subject to change without notice Working temperature Cable diameter Bus-bar size Weight -25°C to +60°C (-13°F to 140°F) (R.H. < 90% non condensing @ 40°C) -30°C to +70°C (-22°F to 158°F) (R.H. < 90% non condensing @ 40°C) CE Screw type From 1.5 to 6 mm2 Min/Max screws tightening torque relevant to terminal block screws: From 1 to 2 Nm Max screws tightening torque relevant to the cable/bus-bar fixing screws: 0,3 Nm IP00 (without sealable terminal covers) IP20 (with sealable terminal block covers + wire terminals) Max. 26 mm Max. 26x32 mm From 450 to 700 g Output Specifications Rated secondary current CTD-5S DS ENG 241008 5 A or 1 A 1 CTD-5S Range Table Wiring Diagram Model CTD-5S from 100A to 400A Primary Burden (VA) Current A CL 1 CL 3 100 1.5 125 1.5 1.5 150 1.5 2.5 200 1.5 5 250 1.5 5 300 2.5 7.5 400 5 10 S1 S2 L P1 P2 N Benefits 1 5 6 • Easy way to open and close the CT core by the dedicate seleable screws (see figure 1). • Bridging of current transformer output without changing the connection of the secondary, so to avoid any output overvoltage during either the maintenance or the installation procedure (see figure 2). • Easy output and earth connection (see fig. 3). • Multiple screws provided with isolation cap screws to grant a strong and reliable fixing of the current transformer to the bus-bar (see figure 4). • Screw terminals compatible with any kind of wire terminals and protection of screw terminals using specific sealable covers to assure always the best safety (see figure 56-7-8). 2 2 3 7 8 4 Dimensions (mm) Specifications are subject to change without notice CTD-5S DS ENG 241008 Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X • Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit. VMU-E, DC energy analysis unit • Instantaneous variables: V, A, W • Instantaneous variables data format: 4-DGTs • Energy measurements: kWh • Energies data format: 6 DGT • Accuracy: class 1 (kWh), ±0.5 RDG (current/voltage) • Direct DC current measurement up to 20A • External shunt DC current measurement up to 1000A • Direct DC voltage measurement up to 400V • Auxiliary power supply from VMU-X unit • Dimensions: 1-DIN module • Protection degree (front): IP40 VMU-E Product Description How to order DC energy analyzer unit with built-in 6 digit display and programming push-button, particularly indicated for DC current, voltage, power and energy metering. Direct connection up to 20A and with external shunt up to 1000A. Moreover the unit is provid- ed with an auxiliary serial communication bus which is connected to the VMU-X unit so to provide an RS485 communication port. Housing for DIN-rail mounting, IP40 (front) protection degree. Model Range code Power supply Internal bus Option Range code Power supply Internal bus Option AV00: 400V DC - 20A (Direct connection) or external shunt input for currents up 1000A (*) XX: X: X: VMU-E AV00 XX X X Type Selection self-power supply from VMU-X unit internal bus compatible only to VMU-X module (*) none (*) as standard. Specifications are subject to change without notice VMU X E DS 250309 1 VMU-E, VMU-X VMU-X, universal power supply and RS485 communication unit or static digital output • Power supply module for VMU-E unit • RS485 communication port (Modbus) • One digital output for pulse retransmission proportional to the energy being measured or for alarm control • 38 to 265 VAC/DC power supply input • Dimensions: 1-DIN module • Protection degree (front): IP40 VMU-X Product Description How to order Universal power supply module suitable to be used in combination to VMU-E unit. In order to improve the communication capability of VMU-E unit, VMU-X can be Model Power supply Communication Option provided with either an RS485 communication port or with a static output. Housing for DIN-rail mounting, IP40 (front) protection degree. VMU-X U S1 X Type Selection Power supply Communication Option U: S1: D1: X: 2 from 38 to 265VAC/DC (*) RS485 Modbus (*) static digital output for pulse retransmission or alarm control (*) (*) as standard. none Specifications are subject to change without notice VMU X E DS 250309 VMU-E, VMU-X General specifications Operating temperature -25 to +55°C (-13°F to 131°F) (R.H. from 0 to 90% non-condensing @ 40°C) Immunity to conducted disturbances Storage temperature -30 to +70°C (-22°F to 158°F) (R.H. < 90% noncondensing @ 40°C) Surge Installation category Cat. III (IEC 60664, EN60664) EMC (Emission) Radio frequency suppression Insulation (for 1 minute) See table “Insulation between inputs and outputs” Standard compliance Safety Dielectric strength 4000 VAC RMS for 1 minute Approvals Noise rejection CMRR EMC (Immunity) Electrostatic discharges Immunity to irradiated Electromagnetic fields Immunity to Burst Housing Dimensions (WxHxD) Material >65 dB, 45 to 65 Hz According to EN61000-6-2 EN61000-4-2: 8kV air discharge, 4kV contact; EN61000-4-3: 10V/m from 80 to 3000MHz; EN61000-4-4: 4kV on power lines, 2kV on single lines; EN61000-4-6: 10V from 150KHz to 80MHz; EN61000-4-5: 2kV on power supply; 4kV on current inputs. According to EN61000-6-3 According to CISPR 22 IEC60664, IEC61010-1 EN60664, EN61010-1 CE 17.5 x 90 x 67 mm Noryl, self-extinguishing: UL 94 V-0 Mounting DIN-rail Protection degree Front Screw terminals IP40 IP20 VMU-E connections Connections Cable cross-section area Current, voltage Current shunt Screw terminal purposes 6/10 mm2 Screw-type Min. 2.5 mm2, max 6 mm2 in case of flexible wire, Max. 10 mm2 in case of rigid wire. Min./Max. screws tightening torque: 0.5 Nm / 1.1 Nm Max 1.5 mm2, Min./Max. screws tightening torque: 0.4 Nm / 0.8 Nm 1.5 mm2 Weight 4 screw terminals: 1 (+) for current input, 1 (+) for current output 2 (+) external shunt input 2 screw terminals: for negative connection Approx. 100 g (packing included) VMU-X connections Connections Cable cross-section area Screw terminal purposes 1.5 mm2 6 Screw-type 1.5 mm2 max. Min./Max. screws tightening torque: 0.4 Nm / 0.8 Nm nals used for static output, 2 screw terminals used for power supply Weight Approx. 100 g (packing included) 3 screw terminals used for RS485 port. 2 screw termi- Specifications are subject to change without notice VMU X E DS 250309 VMU-E, VMU-X VMU-E power supply specifications Power supply Self-power supplied through the VMU-X unit VMU-X power supply specifications Power supply 38 to 265 VAC/DC Power consumption 1.5W, 3VA (VMU-X + VMU-E) VMU-E set of variables No. 1 2 3 4 Variables V A kW kWh Display read-out 0.0 to 999.9 0.0 to 20.00 0.0 to 99.99 0.0 to 99999.9 Notes In case of external shunt input: 0.0 to 999.9 In case of external shunt input: 0.0 to 999.9 In case of external shunt input: 0.0 to 999999 List of the variables that can be displayed and connected to … • RS485 communication port • Alarms No Variable Display RS485 Alarm Reset 1 2 3 4 5 6 7 8 9 10 V V min V max A A min A max kW kW min kW max kWh Yes No No Yes No No Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes No No Yes No No No No Yes Yes No Yes Yes No Yes Yes Yes 11 Alarm No Yes Yes No Specifications are subject to change without notice VMU X E DS 250309 Notes The value is saved into E2PROM The value is saved into E2PROM The value is saved into E2PROM The value is saved into E2PROM The value is saved into E2PROM The value is saved into E2PROM The value is saved into E2PROM There is only one alarm which can be linked to the availale instantaneous variables 7 Energy Management Control solution for Solar PV applications Type Eos-Box • Fan-less embedded PC with Web-server capability • Windows XP embedded operating system • Managed information: V, A, kW, kWh, sun-irradiation, cell-temperature, air- temperature, wind speed on the DC part of the photovoltaic park and V, A, kW, kWh on the AC part and from both inverters and energy meters. • Efficiency calculation and control on three different levels: string, BOS and total • Variables shown as graphs and numbers in formatted tables • Alarms control and automatic e-mailing and SMS management in case of GPRS modem external connection • All data exports on XLS format • Data storage up to 15 years in a 8GB DOM Memory • Four RS485 communication ports (Modbus) • One Ethernet port • 100 to 240VAC power supply • Dimensions(WxHxD): 225 x 225 x 45 mm • Protection degree (front): IP20 Product description Eos-Box is a fan-less embedded PC with Web-server capability suitable to gather photovoltaic plant information from Eos-Array, inverters, energy meters and interface protection. Eos-Box provides information in a quick and automatic fashion via the internet using a standard browser, so the data is avail- How to order able wherever you are. EosBox shows information such as: V, A, kW, kWh, sun-irradiation, cell-temperature, airtemperature, wind speed on the DC part of the photovoltaic park and V, A, kW, kWh on the AC part coming from both inverters and energy meters. All data are available as graphs and numbers in for- Model Power supply Option Special features Option Special features matted tables. Eos-Box performs alarms control managing also automatic e-mailing and SMS when proper GPRS Eos-Box D XX X modem is connected. All available data can be exported as spread sheets for further analysis. Type Selection Power supply D: from 100 to 240VAC (*) XX: none (*) X: none (*) (*) as standard. Hardware Type Operating system Operation Processor Chipset Embedded PC Windows XP embedded Fan-less AMD LX800 500 MHz AMD LX+CS5536+ITE8888G BIOS Phoenix-Award 4Mbit with RPL/PXE LAN Boot ROM. SmartView and customer CMOS backup Memory DDR DOM Back-up Industrial CompactFlash™ Communication ports RS485 Ethernet Other ports USB 256MB SODIMM 8GB 3 ports for Eos-Array bus management 1 port for Inverter, Interface protection and Energy meters 1 for internet/LAN connection 1 for local access 3, for local access and service 8GB Type II (on request) Specifications are subject to change without notice Eos-Box DS 280909 1 Eos-Box Hardware (cont.) LED Status and colour Connections RS485 RJ-45 connector (10/100Base-T) High speed USB 2.0 Ethernet Green for power-on Orange for DOM memory access USB 3 pole detachable screw terminal block per port RS485 communications ports Type Connections Addresses Protocol Data (bidirectional) Data format Master function, Multidrop, bidirectional (static and dynamic variables) 2-wire. Max. distance 1000m 247 MODBUS/JBUS (RTU) All variables Selectable: 1 start bit, 7/8 data bit, no/odd/even/ Baud-rate Driver input capability Insulation mark/space parity,1/1.5/2 stop bit Selectable: 9600, 19200, 38400, 115200 bits/s 1/5 unit load. Maximum 160 transceivers on the same bus. See the table “Insulation between inputs and outputs” Example of communication architecture Remote reading of Solar plant Eos-Array A...C Eos-Array D...F RS485 Eos-Box Eos-Array G...I Eos-Array L...N RS485 Eos-Array O...Q Eos-Array R...T RS485 RS485 kWh meter Inverter group 1...5 Inverter group 10...15 Inverter group 6...10 2 Specifications are subject to change without notice Eos-Box DS 280909 ISMG Solar Inverter • High PV input voltage range (suitable for voltage between 100 VDC to 450VDC) and efficient MPP Tracking • Up to 2 / 3 independent MPP Tracking controlled by an exclusive Smart MPPT Technology • Transformerless (equipped with electronical RCMU device for galvanic insulation) • Integrated security and filtering system according to relevant EMC standards • RS232/RS485 serial communication for local/remote control • Integrated data display (2 x 16 LCD) and LEDs for monitoring of the operational status and signalling of failures • Active anti-islanding protection for grid monitoring able to ensure high safety level for qualified installers and end users • Integrated interface protection device for monitoring the grid according to the national standards • High reliability, light weight, easy to install and start up, large cost saving • IP 65 protection degree (can be installed outdoors or indoors) ISMG 1 60 General description The Onyx Solar ISMG PV solar inverter series converts direct current from the solar cells into alternating current. This enables you to feed your self-produced solar energy into the public grid. The integrated security and monitoring system guarantees an high disturbance immunity according to relevant electromagnetic compatibility standards and enable the highest levels of efficiency. Ordering key The exclusive Smart MPPT technology allows to control up to 2/3 independent strings of PV panels and it ensures the increase of energy up to 20%, thanks to the fully functional PV string control software. The maximum capacity utilization of the solar energy plant is guaranteed even in case of a misty and clouded over sky. The high input voltage range of the solar inverter enables to use ISMG 1 50 ES Model Grid connection Max. DC power Country PV modules from different manufacturers. Integrated data display ensures an immediate monitoring of the inverter operational status and failure messages. The internal temperature control protects the device against too high temperatures in the interior of the solar inverter. In case of high ambient temperatures, the external cooling fans switch them on. The solar inverter is functional in grid parallel operation exclusively. The automatically-acting isolation point, guarantees secure disconnection in case of circuit isolation or interruptions in power supply and it avoids isolated operation. Type selection Grid connection Single Phase Max. DC power 4.5kW 5.0kW 6.0kW Country ES IT DE 1 45 50 60 Spain Italy Germany Approvals RD 1663/2000 RD 661/2007 DK5940 1 2 Ed. 2.2 April 2007 VDE0126-1-1 Notes: (1) (2) (3) 1 3 Spanish Reccomandation Italian Reccomandation German Reccomandation Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 191208 ISMG Solar Inverter Photovoltaic DC input data Model Nominal DC power Max. DC power Max. recommended PV power Nominal voltage Max. DC voltage Min. DC voltage (Pnom) MPP voltage range Full MPP range Max. DC current per each string DC current range per each string Number of MPP trackers Max. No. of parallel strings for MPP Overvoltage protection Ground fault monitoring Polarity safeguard Surge absorption ISMG 1 45 3.48kW 4.0kW 4.5kW ISMG 1 50 4.0kW 4.64kW 5.0kW 450V 500V 150V 100...450V 300...400V 10A 0...10A 1~2 2 ISMG 1 60 4.85kW 5.38kW 6.0kW 1~3 3 Yes Yes Short circuit diode MOV varistor AC output data Model Nominal AC power Max. AC power Power factor Distortion factor (THD) Grid connection AC voltage range AC nominal current AC current range Frequency range Safety class All Pole sensitive RCMU ISMG 1 45 3.3kW 3.8kW ISMG 1 50 ISMG 1 60 3.8kW 4.6kW 4.4kW 5.1kW > 0.99 < 3% Single phase; True sine-wave Spain: 196...253V (VACnom.: 230V) - Italy: 184...276V (VACnom.: 230V) Germany: 184...264V (VACnom.: 230V) 14.34A 16.52A 20A 0...16.52A 0...19.13A 0...22A Spain: 49...51Hz (fnom.: 50Hz) - Italy: 49.7...50.3Hz (fnom.: 50Hz) - Germany: 47.5...50.2Hz (fnom.: 50Hz) I Yes General features Model Max. efficiency EU efficiency Stand-by consumption Night consumption Protection device Anti-islanding monitoring Grid monitoring ISMG 1 45 96.2% @ 350VDC 95.4% @ 350VDC ISMG 1 50 ISMG 1 60 96.3% @ 350VDC 95.1% @ 350VDC 95.4% @ 350VDC < 10W 0W Grid monitoring system Yes Integrated interface protection (Spain: according to RD 1663/2000; RD 661/2007) (Italy: according to DK5940 Ed. 2.2 April 2007) (Germany: according to VDE0126-1-1) ISMG 1 45 0°C...+60°C / 32°F...140°F without derating; Shut-down at 75°C/167°F ISMG 1 50 Environmental data Model Operating temperature @ 350VDC Max. acceptable temperature @ Pnom Storage temperature Humidity Temperature control Cooling Protection degree Installation location Noise level ISMG 1 60 0°C...+55°C / -32°F...131°F without derating; Shut-down at 75°C/167°F +55°C / 131°F -25°C...+80°C / -13°F...176°F 0...95% Automatic temperature control by software Forced ventilation (2 x IP54 external fans) IP 65 (according to DIN EN60529) Outdoor / Indoor < 40dB Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 191208 2 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Type DPC02 • TRMS 3-phase over and under voltage, over and under frequency, phase sequence and phase loss monitoring relay • Detect when all 3 phases are present and have the correct sequence • Detect if all the 3-phase-phase or phase-neutral voltages are within the set limits • Detect if the system frequency is between the set limits • Separately adjustable setpoints • Separately adjustable delay functions (0.1 to 30 s) • Output: 2 x 8 A relay SPDT • For mounting on DIN-rail in accordance with DIN/EN 50 022 • 45 mm Euronorm housing • LED indication for relays, alarm and power supply ON Product Description Ordering key 3-phase or 3-phase+neutral line voltage monitoring relays for phase sequence, phase loss, over and under voltage (separately adjustable set points), over and under frequency with built-in time delay function. Housing Function Type Item number Output Power Supply Supply ranges from 208 to 690 VAC covered by four multivoltage relays. The main application is for generator sets. DPC 02 D M48 Type Selection Mounting Output Supply: 208 to 240 VAC Supply: 380 to 415 VAC Supply: 440 to 480 VAC Supply: 600 to 690 VAC DIN-rail 2 x SPDT DPC 02 D M23 DPC 02 D M48 DPC 02 D M49 DPC 02 D M69 Input Specifications Input L1, L2, L3, N DPC02: Terminals L1, L2, L3, N Measure on own supply Note: Connect the neutral only if it is intrinsically at the star centre Measuring ranges (voltage) M23 177 to 275 ∆VAC M48 323 to 475 ∆VAC M49 374 to 552 ∆VAC M69 510 to 793 ∆VAC Measuring ranges (frequency) Upper level Lower level Selectable by DIP-switches 2 Hz range +0.2 to +2.2 Hz -2.2 to -0.2 Hz 50.2 to 52.2 Hz 47.8 to 49.8 Hz 50 Hz 60 Hz 60.2 to 62.2 Hz 57.8 to 59.8 Hz 15 Hz range +1.5 to +16.5 Hz -16.5 to -1.5 Hz 51.5 to 66.5 Hz 33.5 to 48.5 Hz 50 Hz 61.5 to 76.5 Hz 43.5 to 58.5 Hz 60 Hz Specifications are subject to change without notice (19.07.06) Ranges Upper voltage level Lower voltage level Frequency window Hysteresis (frequency) 2 Hz range 15 Hz range +2 to +22% of the nominal voltage -22 to -2% of the nominal voltage 10 to 110% of the selected range ~ 0.05 Hz ~ 0.25 Hz Note: The input voltage must not exceed the maximum rated voltage or drop below the minumum rated voltage reported above. 1 DPC02 Operation Diagrams (cont.) L1 or L1-L2 Upper voltage Hysteresis L2 or L2-L3 Hysteresis Lower voltage L3 or L3-L1 Relay 1 Voltage Red LED ON Power ON T1 T1 T1 T1 T1 Power ON Relay 2 Frequency Relays (DPDT NE) T2 Power ON Power ON T2 T1 Frequency (+) Hysteresis Nominal Frequency Hysteresis Frequency (-) Wiring Diagrams Ex.1 4 Ex.2 Specifications are subject to change without notice (19.07.06) Monitoring Relays Frequency Monitoring Types DFB01, PFB01 DFB01 • Over/under frequency monitoring relays • Measuring if power supply frequency is within set limits • Measure on own power supply • Measuring ranges Voltage: 24 to 240 VAC Frequency: 50 - 60 Hz • Separately adjustable upper/lower level on relative scale • Adjustable delay on alarm or on recovery (0.1 to 30 s) • Programmable latching or inhibit at set level • Output: 8 A SPDT relay N.D. or N.E. selectable • For mounting on DIN-rail in accordance with DIN/EN 50 022 (DFB01) or plug-in module (PFB01) • 22.5 mm Euronorm housing (DFB01) or 36 mm plug-in module (PFB01) • LED indication for relay, alarm and power supply ON PFB01 Product Description Ordering key DFB01 and PFB01 are precise frequency monitoring relays. The relays monitor their own power supply from 24 to 240 VAC. The advantage of using the latch function is that the relay can be kept energized Housing Function Type Item number Output Power Supply even after the end of the alarm condition. Inhibit function can be used to avoid relay operation when not desired (maintenance, transitions). The LED's indicate the state of the alarm and the output relay. DFB 01 C M24 Type Selection Mounting Output Measuring range Supply: 24 to 240 VAC DIN-rail Plug-in SPDT SPDT 50-60 Hz 50-60 Hz DFB 01 C M24 PFB 01 C M24 Input Specifications Output Specifications Input Own power supply DFB01: PFB01: Measuring ranges Selectable by DIP-switches 2 Hz range 50 Hz 60 Hz 10 Hz range 50 Hz 60 Hz Contact input DFB02 PFB02 Disabled Enabled Pulse width Hysteresis 2 Hz range 10 Hz range Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life A1, A2 (24 to 240 VAC) 2, 10 (24 to 240 VAC) Upper level Lower level -0.2 to +2 Hz 49.8 to 52 Hz 59.8 to 62 Hz -1 to +10 Hz 49 to 60 Hz 59 to 70 Hz -2 to +0.2 Hz 48 to 50.2 Hz 58 to 60.2 Hz -10 to +1 Hz 40 to 51 Hz 50 to 61 Hz Terminals Z1, Z2 Terminals 8, 9 > 10 kΩ < 500 Ω > 500 ms SPDT relay 250 VAC µ 8A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 8 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h Operating frequency Dielectric strength Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs) ~ 0.05 Hz ~ 0.25 Hz Specifications are subject to change without notice (18.01.07) 1 DFB01, PFB01 Operation Diagrams Normally energized relay - Latch function Wiring Diagrams PFB01 DFB01 Dimensions DIN-rail Plug-in 94 90 63 28.5 Specifications are subject to change without notice (18.01.07) 80 36 63 99.5 83.5 80 22.5 28.5 3 Monitoring Relays 1-Phase Voltage selection Type DUA55 • Detects if voltage is at the desired level (± 10% or ±15%) • Measures own power supply • Wide power supply range: 208 to 480 VAC (±15%) • Output: 5 A SPDT relay normally energized • For mounting on DIN-rail in accordance with DIN/EN 50 022 • 17.5 mm DIN-rail housing (DIN 43880) • LED indication for relay and power supply ON Product Description Ordering Key 1-Phase relay for detection of incorrect mains voltage. This unit allows to stop incorrect power supply voltage when different from the desired one. Power supply range from Housing Function Type Item number Output Power supply 208 to 480 VAC plus selection of the different possible nominal voltages. For mounting on DIN-rail. Housing 17.5 mm wide suitable both for back and front panel mounting. DUA 55 C M44 Type Selection Mounting Output Supply: 208 to 480 VAC DIN-rail SPDT DUA 55 C M44 Output Specifications Input Specifications Input L, N Measuring range Terminals A1, A2 Measures on own supply 177 to 550 VAC Supply Specifications Power supply Rated operational voltage through terminals: A1, A2 Rated operational power Overvoltage cat. II (IEC 60664, IEC 60038) 208 to 480 VAC ± 15%, 45 to 65 Hz 6 VA @ 230 VAC, 50 Hz Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life SPDT relay, N.E. 250 VAC µ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 8 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h Operating frequency Dielectric strength Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs) General Specifications Reaction time Alarm ON delay Alarm OFF delay Accuracy Temperature drift Repeatability Indication for Power supply ON Relay ON < 100 ms < 300 ms (15 min warm-up time) ± 1000 ppm/°C ± 0.5% on full scale LED, green LED, yellow Specifications are subject to change without notice (07.07.06) Environment Degree of protection Pollution degree Operating temperature @ Max. voltage, 50 Hz @ Max. voltage, 60 Hz Storage temperature Housing Dimensions Material Weight IP 20 2 -20 to +60°C, R.H. < 95% -20 to +50°C, R.H. < 95% -30 to +80°C, R.H. < 95% 17.5 x 81 x 67.2 mm PA66 Approx. 80 g 1 DUA55 General Specifications (cont.) Mode of Operation Screw terminals Tightening torque DUA55 monitors its own 1- phase power supply. The relay operates when the monitored voltage is within the desired tolerance (± 10% or ± 15%). Max. 0.5 Nm acc. to IEC 60947 UL, CSA Yes Electromagnetic Compatibility According to EN 61000-6-2 According to EN 61000-6-3 Approvals CE Marking EMC Immunity Emission Example The relay monitors that the power supply is the correct one for the required equipment. Range setting Select the proper nominal voltage level using DIPswitches as shown below. Voltage window ON: ± 15 % OFF: ± 10 % Measuring range SW2 OFF OFF OFF OFF 208 VAC 220 VAC 230 VAC 240 VAC SW3 OFF OFF ON ON SW4 OFF ON OFF ON Operation Diagram Set level Voltage window Power supply Relay ON Dimensions Wiring Diagram 17.5 67.2 18.7 m U 11 2 A2 45 14 12 81 A1 2 Specifications are subject to change without notice (07.07.06) Monitoring Relays Surge Arresters for AC and DC systems Types DSA A, DSA P, DSA D • Type 2 (class C) according to EN61643-11 (VDE 0675, part 6-11) • Suitable for TN-S and TT systems • Plug-in cartridges • Optical indication of the correct working of the cartridge (green/red window) • Voltage-free contact, for remote function monitoring • Including thermal and dynamic separating device • Assembled unit ready for mounting • Marked connections • For DIN-rail mounting Product Description Ordering Key DSA A, DSA P and DSA D are Type 2 (Class C) surge arresters according to EN 61643-11 (VDE 0675, part 6-11) suitable for protecting low voltage systems from transient overvoltage due to both indirect atmospheric discharges and switching actions. DSA for AC systems (range 280N) has a gas tube between N and PE: therefore it is universally suitable for the TN-S, and TT power supply systems (mounting upstream the differential relay), preventing impermissible, high contact voltages. The DC models are available both in 2-pole or 3-pole configurations, allowing both differential and common mode protection. Description Mounting DIN-rail The control windows (green/red indication) and the contact allow both a local and a remote monitoring of the status of the plugin cartridges, warning the operator about the need to promptly replace the cartridges themselves. In buildings without external LPS (Lightning Protection System), DSA can be used in industrial and residential applications, AC and DC side of photovoltaic generation plants and can be installed on a DIN-rail in every commercially available distribution box. DSA 52 C A 280N Code D Function Surge arresters S Type Type 2 (class C) A Cartridge dimensions 17.5 mm 5 Configuration 2-pole 3-pole 4-pole 2 3 4 Contact None 1 (relay) X C Network 1-phase AC 3-phase AC DC A P D Range 585 VDC 585 745 VDC 745 1000 VDC 1000 280 VAC with NPE 280N Type Selection Code Description DSA52CD585 DSA53CD585 DSA52CD745 DSA53CD745 DSA53CD1000 DSA53XD1000 2-pole surge arrester for P.V. installations 3-pole (∆) surge arrester for P.V. installations 2-pole surge arrester for P.V. installations 3-pole (∆) surge arrester for P.V. installations 3-pole (Y) surge arrester for P.V. installations 3-pole (Y) surge arrester for P.V. installations 1-phase surge arrester (1+1) for TN and TT systems 3-phase surge arrester (3+1) for TN and TT systems DSA52CA280N DSA54CP280N Specifications are subject to change without notice (25.08.09) Max. cont. Output relay operating voltage 585 VDC SPST 585 VDC SPDT 745 VDC SPST 745 VDC SPDT 1000 VDC SPDT 1000 VDC No 280 VAC (L-N) SPST 280 VAC (L-N) SPST Cartridge 2x DS0440 3x DS0440 2x DS0550 3x DS0550 3x DS0440 3x DS0440 1x DS0280 1x DS255N 3x DS0280 1x DS255N 1 DSA Wiring Diagrams Type AC Type AC Type DC Type DC Type DC Type DC Specifications are subject to change without notice (25.08.09) 3 Monitoring Relays Surge Arresters for communication systems Type DSA S • Universal surge arrester for 2-wire communication bus • Basic, medium and fine protection • High transfer frequency • Screwless connection • DIN-rail mounting Product Description Ordering Key DSA S is a surge protection for electronic measuring, controlling and regulating systems. It is suitable for protecting from overvoltages devices like inverters, energy meters, interface protections (coupling devices), control and acquisitions systems in photovoltaic installations. Model DSA51XXS has been developed for 2-wire com- Mounting Function Type Item number Output Network Range munication buses (e.g. Modbus RTU, Dupline), can be used in industrial and residential applications, in the communication system of photovoltaic generation plants, etc., and can be installed on a DIN-rail in every commercially available distribution box. DSA 51 X X S Type Selection Code Description DSA51XXS Surge arrester for 2-wire communication bus Nominal voltage of Output relay the system 24 V No Cartridge - General Specifications Nominal voltage Max. continuous operating voltage AC Max. continuous operating voltage DC LPZ Transmission frequency Pulsed current (10/350) Nominal discharge surge current (8/20) Un 24 V Uc AC 19.7 VAC Uc DC 28 VDC 0 --> 3 0 to 100 MHz Iimp 6 kA In 20 kA Specifications are subject to change without notice (21.05.09) Nominal load current Protection level wire/wire Protection level wire/earth Series resistance Response time Protection distance Temperature range Screw terminals Cable cross-section area Protection degree Dimensions CE Marking IL 0.45 A < 40 V < 500 V 2.2 Ohm < 1 ns 10 m (suggested value) -40 to +80 °C Screwless 0.14 to 2.5 mm2 IP 20 17.5 x 90 x 62 mm Yes 1 Temperature probe TEMPSOL • Self-adhesive probe • Pt100 or Pt1000 sensor type • Encapsulate aluminium enclosure TEMPSOL1000 Product Description Ordering Key Temperature probe with Pt100 or Pt1000 sensor encapsulated in an aluminium body. Easy installation by a self- Model Sensor Type adhesive surface. Special design to measure the temperature of plane surface (like the solar panel). General Data 1000 = Pt1000 0100 = Pt100 Option Mechanical Data Sensor Pt100 and Pt1000 Tolerance Accuracy Dimension TEMPSOL 1000 -30°C...+150°C (200°C max.) -22°F...+302°F (392°F max.) 0°C ±0.3°C 32°F ±0.3°F Class B according to EN60751/DIN43760 Sensor type Mounting Housing Dimensions (mm/inches) Connection Type Diameter Length (m/ft) Insulating material Thermoresistance Pt100 ro Pt1000 Selfadhesive 30x10mm Encapsulate aluminium 10x30x5 / 0.39x1.18x0.19” 2 wires 26AWG 2 / 6.56 White Twisted Teflon (mm/inches) 2000/78.74 10/0.39 30/1.18 5/0.19 2x26AWG Selfadhesive 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 280809 Irradiation Sensor Model CELLSOL 200 • • • • Solar irradiation measure Output ~75mV @ 1000W/m2 Light and strong device with an easy installation Two wire cable, UV proof, length 3m CELLSOL 200 Product Description CELLSOL 200 is a silicon sensor for the measurement of the solar irradiation. The device provides a voltage output in mV, proportional to the standard irradiation of 1000W/m2. Every sensor brings in plate the value calibrated in mV related to the full scale. Normally used for controlling the efficiency of the photovoltaic plants. General Specification Range Accuracy Output from 0 to 1500W/m2 ±5%, annual average Approx. 75mV @ 1000W/m2 Ordering Key CELLSOL 200 Model Sensor Characteristics Sensor type Mounting Cell dimension Mono-crystalline cell Novaflon and EVA sheet 6 x 33mm (true value is reported on the label) Mechanical Specification Fixing Weight Warranty Anodized aluminium 110 x 40 x 40mm UV proof 3m 1 hole Ø6mm ~200g (with cable) 2 years 45mm 45mm Main structure Cable dimension Dimensions 40mm 70mm 33mm Ø6mm 16mm 40mm 1 15mm Specifications are subject to change without notice. Pictures are just an example. For special features and/or custumization, please ask to our sales network. 220808 Cup Anemometer PVC Housing, Rotor of black painted Stainless Steel Type DWS-V-DAC13 • Anemometer with opto-electronic detection • Measuring range: 2 to 30 m/s • PNP and NPN open collector outputs in the same unit • Current source outputs • 10 to 28 VDC supply voltage • All inputs and outputs are protected against reverse polarity and transients • High ESD protection • Built-in heater • Dust sealing Product Description DWS-V-DAC13 is a cup anemometer designed for measuring air speed in a wide variety of applications, including wind turbines, buildings, cranes, weather stations, green-houses, etc. The product contains both PNP- and NPN open collector outputs, in which a fixed current is switched proportionally to the air speed at the rate of 10 pulses per m/s. A built-in self-regulated heater reduces the risk of glazing. The heater is supplied separately, which makes it possible to control the heating. The DWS-V-DAC13 is equipped with a specially designed protection mechanism, which protects the bearings and the electronic parts against dirt and humidity. The body of the sensor is made of black PVC, and the rotor is produced in stainless steel. Specifications Rated operational voltage UB UC Supply current (without heater) off) Measuring range Accuracy Ordering Key DWS-V-DAC13 Type Air velocity Digital output (Future subtypes) Cable Version Standard cable length in full metres*) *) can be specified by customer General Specifications 12 to 24 VDC 10 to 28 VDC Approx. 20 mA (all outputs 1.5 to 30 m/s ≤ 3 m/s: ±0.5 m/s ≥ 3 m/s: ±10% Dimensions Rotor diameter Thread Materials Body Rotor 145 mm External thread: M28 x 2 with one nut Black PVC Stainless steel (AISI 303), black painted Instrument ball bearings, Bearings stainless steel Output Specifications Signal output NPN Open Collector constant current sink PNP Open Collector constant current source Output frequency Output power Load supply voltage Voltage drop Square wave 12.5 mA ± 2mA Square wave 12.5 mA ± 2mA 10 Hz per m/s ≤ 250 mW Min. 10 VDC Max. 28 VDC Typ. 4.9 VDC Specifications are subject to change without notice (15.12.05) Cable Rotor/housing tightening Environment Degree of protection Ambient humidity Climatic protection and dust Ambient temperature Operating temperature Storage temperature Heating system Heater Supply voltage 13 m shielded grey PVC, 6 x 0.25 mm2 Dust labyrinth IP54 0 to 100% RH Against high humidity, salt -20 to 60°C (-4 to +140°F) -20 to 60°C (-4 to +140°F) > -20°C (> -4°F) PTC-element 12 to 24 VAC/DC on separate wires 1 DWS-V-DAC13 General Specifications (cont.) Inrush current Power consumption 1.5 A @ -20°C (-4°F): app. 10 W @ +20°C (+68°F): app. 5 W @ +60°C (+140°F): app. 1.5 W EMC IEC 61000-4-2 Contact discharge ± 4 kV Air discharge ± 8 kV IEC 61000-4-3 Radiated radio-frequency 15 V/m Electromagnetic fields IEC 61000-4-4 Fast transients/burst Power port, performance B± 2 kV Signal port, performance B ± 1 kV Dimensions IEC 61000-4-5 Surge 1.2/50 µs Power port, Ri = 2 Ω Signal port, Ri = 47 Ω IEC 61000-4-6 Conducted disturbances induced by radio-frequency fields Mounting position Weight packaging 500 V 2000 V 12 Vrms Vertical with M28 thread 1.1 kg incl. 13 m cable and Wiring Diagram 145 Brown (+) Current Generator PNP O.C. Beige Current Generator NPN O.C. Black 183 137 Sensor Blue (-) Green M28 X 2 Heater Yellow All dimensions in mm Shield PV output versus wind speed Frequency [Hz] 300 250 Frequency Hz 200 150 100 50 0 0,00 2 5,00 10,00 15,00 20,00 25,00 30,00 Wind speed [m/sec] Specifications are subject to change without notice (15.12.05) Digital Indicator DPY30 • Visibility >30m • Serial connection to Carlo Gavazzi meters for power and energy control • Serial communication RS485 2 wires, MODBus-RTU protocol (Max. distance ≤1200m) • Automatic brightness adjustment DPY307050HX General Description Ordering key Digital indicator for renewable energy plants. Suitable for indoor and outdoor environments (semiexposed). Large display with Model Series Dimensions Option (HX= standard; HP= custom) 3-lines for visualization of differents instantaneous process values. Customizable front design and dimensions. DPY307050HX Approvals General Data Display Data Connection type Power supply RS232 / RS485 COM port 230VAC @ 50Hz Mechanical Data Housing material Frontal screen Frontal layout Fixing devices Nuts/screws material Weight Dimensions (LxHxD) Installation location Protection degree 1 Aluminium Anti mirror screen Standard or custom (vinyl with 4 colours) Wall mounting brackets Stainless Steel 10kg 700x500x70mm Indoor/outdoor IP40 Number of lines Number of digit per line Digit dimension (LxH) Pixel type Pixel colour Number of pixel Step Brightness regulation 3 5+6+6 50x70mm 1 high brightness LED 1 (red or yellow) 714 10mm Automatic by crepuscular sensor Display Information Instant Power Number of digit Managed by Total Energy Number of digit Managed by Saved Emissions Number of digit Managed by 5 EM24DIN energy meter 6 EM24DIN energy meter 6 Automatic (CPU display) Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 080908 SunBright Solar Battery Charger • • • • • • 12VDC, 24VDC system voltage 6A, 10A, 20A and 30A battery current ratings 8 automatic charging programs (bulk, float, equal) Charge LED status Battery Temperature Sensor (BTS) Manual / Auto Equalization SBC 30A Product Description Ordering Key SunBright is a solar battery charger device with an advanced design using a microcontroller for digital accuracy and fully automatic operation. Each model unit can be used for 12V and 24V Serie Models system for solar battery charging. The PWM battery charging has been optimized for longer battery life. SBC 30A Approvals Type Selection Serie SBC Solar Battery Charger Models 6A 10A 20A 30A 6A Current rating battery charge 10A Current rating battery charge 20A Current rating battery charge 30A Current rating battery charge Electrical Data Model System voltage ratings Current ratings Battery Charge Control Accuracy Min. / Max operating voltage Max. solar array Voc Current consumption SBC 6A 12VDC SBC 10A SBC 20A 12, 24VDC SBC 30A 6A 10A 20A 30A High temperature shutdown N/A ±60mV 6V/16V 30V 6mA 12/24V: 0.1% ± 50mV 9V/34V 50V 9mA 90ºC disconnect solar 70ºC reconnect solar Battery Charging/Built-in BTS Data Model Charge algorithm Temp comp. coefficient Temp comp. range Temp comp. setpoints SBC 6A SBC 10A SBC 20A PWM (Pulse Width Modulation), constant voltage -5mV/ºC / cell 12V: -5mV/ºC / cell (25ºC ref) (25ºC ref) 24V: -10mV/ºC / cell (25ºC ref) 0ºC to +50ºC PWM setpoint: 14.1V PWM, float, equalize (with BTS) SBC 30A Environmental Data Model Ambient temperature Storage temperature Humidity Enclosure SBC 6A SBC 10A SBC 20A -40 to +45ºC -55 to +85ºC 100% (Non Condensing) Indoor and vented (power coated steel) Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 300709 SBC 30A 1 SunBright Solar Battery Charger Mechanical Data Model Weight Enclosure Optional remote panel SBC 6A 0.2kg General Overview SBC 10A SBC 20A SBC 30A 0.3kg 0.4kg Indoor & natural air convection, (powder coated steel) Not available Optional LCD display Minimum Clearance Dip Switches Charge status LED 5cm/1.97” 5cm/1.97” 5cm/1.97” 5cm/1.97” Battery Neg.- PV+ Reset/Stop equalization PV- BTS Battery Pos.+ Remote Panel Install the device vertically and leave at least 5cm all around in order to improve cooling. Wiring Diagram 1st Connect the Battery 2nd Connect the Photovoltaic panel (PV array) + - + + 2nd 1st - Note: • The device prevents reverse current leakage at night, so a blocking diode is not required in the system. • The terminals will accept a maximum wire size of AWG#10 (up to 5.2mm2). (Some #10 spade connectors may not fit in this terminal.) • Tighten each terminal screw maximum to 2.26Nm (20inch-pounds) of torque. • It is designed to regulate power from a PV array. However other generators can be connected directly to the battery, with no effect on this device. • A battery below 10V may not start the microcontroller properly. Make sure the battery is charged before installing the system. • Reverse polarity: verify the polarity (+ and -) before applying power. Dimensions (mm) SBC 10A - SBC 20A 2 168 100 161 65 107 35 35 65 SBC 6A Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 300709 SunBright Solar Battery Charger with Load Control • • • • • • • • • 12VDC, 24VDC, 48VDC system voltage 10A, 20A and 30A battery current ratings 8 automatic charging programs (bulk, float, equal) Charge LED status Load LED status Light / Load control Lighting set-up mode Battery Temperature Sensor (BTS) Manual / Auto Equalization SBCLC 10A Product Description Ordering Key SunBright is a solar battery charger and a load/light control device with an advanced design using a microcontroller for digital accuracy and fully automatic operation. Each model unit can be used for 12V, 24V and 48V system and can be operated at three major functions including solar charging, load control and lighting control. Serie Models The PWM battery charging has been optimized for longer battery life and the state-ofthe-art auto detector of day and night has been precisely applied to log the different length of night hours for lighting control no matter where and when (the North or the South, winter or summer) SunBright is installed. SBCLC 10A Approvals Type Selection Serie SBCLC Solar Battery Charger and Load/Light Control Models 10A 20A 30A 10A Current rating battery charge 20A Current rating battery charge 30A Current rating battery charge Electrical Data Model System voltage ratings Current ratings Battery Charge Control Current ratings Load Control/Lighting Control Accuracy Min. / Max operating voltage Max. solar array Voc Current consumption SBCLC 10A SBCLC 20A 12, 24, 48VDC SBCLC 30A 10A 20A 30A 10A 20A 30A High temp shutdown LVD (Low Voltage Disconnection) LVR (Low Voltage Reconnection) 11.1V 22.2V 44.4V 12.6V 25.2V 50.4V (default), (default), (default), (default), (default), (default), Overload Capacity 12/24V: 0.1% ± 50mV - 48V: 0.1% ± 100mV 9V / 68V 140V -25mA, (idle -3mA) 90ºC disconnect solar 90ºC disconnect load / diversion load 70ºC reconnect solar / load / diversion load 10.5V, 11.3V, 11.5V, 11.7V, 11.9V, 12.1V, 12.3V for 12V system 20.1V, 22.6V, 23.0V, 23.4V, 23.8V, 24.2V, 24.6V for 24V system 42.0V, 45.2V, 46.0V, 46.8V, 47.6V, 48.4V, 49.2V for 48V system 12.0, 12.8V, 13.0V, 13.2V, 13.4V, 13.6V, 13.8V for 12V system 24.0, 25.6V, 26.0V, 26.4V, 26.8V, 27.2V, 27.6V for 24V system 48.0, 51.2V, 52.0V, 52.8V, 53.6V, 54.4V, 55.2V for 48V system 150% of rated current for transient surge Battery Charging/Built-in BTS Data Model Charge algorithm Temp comp. coefficient Temp comp. range Temp comp. setpoints SBCLC 10A SBCLC 20A SBCLC 30A PWM (Pulse Width Modulation), constant voltage -5mV/ºC / cell (25ºC ref) 0ºC to +50ºC PWM, float, equalize (with BTS) Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 090409 1 SunBright Solar Battery Charger Environmental Data Model Ambient temperature Storage temperature Humidity SBCLC 10A SBCLC 20A -40 to +45ºC -55 to +85ºC 100% (Non Condensing) SBCLC 30A Mechanical Data Model Weight Enclosure Optional remote panel SBCLC 10A SBCLC 20A SBCLC 30A 0.3kg 0.4kg Indoor & natural air convection, (powder coated steel) Not available Optional LCD display General Overview Minimum Clearance Dip Switches Load status LED Charge status LED Lighting Set-up 5cm/1.97” 5cm/1.97” 5cm/1.97” 5cm/1.97” Battery Load+ Pos.+ Light+ PV+ PV- Manual EQU/LVR Battery LoadNeg.- Light- Light test BVS +- Remote Panel BTS Install the device vertically and leave at least 5cm all around in order to improve cooling. Wiring Diagram 1st Connect the Battery 2nd Connect the Photovoltaic panel (PV array) 3rd Connect the load/light + - + + + 2nd 2 1st Note: • The device prevents reverse current leakage at night, so a blocking diode is not required in the system. • The terminals will accept a maximum wire size of AWG#10 (up to 5.2mm2). (Some #10 spade connectors may not fit in this terminal.) • Tighten each terminal screw maximum to 20x0.1130Nm (20inch-pounds) of torque. • It is designed to regulate power from a PV array. However - other generators can be connected directly to the battery, with no effect on this device. rd • A battery below 10V may not start the microcontroller properly. Make sure the battery is charged before installing the system. 3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 090409 PSI series Pure Sinusoidal Inverter • • • • Load sense Low battery cut-off Great overload performance Do not effect other equipment like TV, radio, microwave ovens, etc... • High efficiency • Aluminium chassis for harsh environments • 89/336/EEC, 92/31/EEC and 93/68/EEC PSI Product Description Ordering Key These pure sinusoidal wave inverter series is especially designed to fulfil the needs of applications where it is necessary to adapt several parameters of inverters to Serie Output Power Socket type Input type Output type the loads. It includes a low frequancy transformer (toroidal transformer) to isolate the DC circuit (input) from the AC circuit (output). PSI 1500 U 12 1 Approvals Output Power 0150 0300 0600 1000 1500 3000 Socket Type 150W 300W 600W 1000W 1500W 3000W Input Type 12 24 48 E U European Universal Output Type 12VDC 24VDC 48VDC 1 2 115VAC / 60Hz 230VAC / 50Hz Electrical Data PSI 0150 12 x x PSI 0300 12 x x PSI 0600 12 x x PSI 1000 12 x x PSI 1500 12 x x PSI 3000 12 x x PSI 0150 24 x x PSI 0300 24 x x PSI 0600 24 x x PSI 1000 24 x x PSI 1500 24 x x PSI 3000 24 x x 150W 300W 600W 1000W 1500W 3000W Continous output power 250W 450W 900W 1500W 2000W 4000W Output power surge 100~120V ±2% - 200~240V ±2% adjustable AC output voltage -4%~+4% -1.5%~+1.5% all models Output voltage regulation 60Hz ±0.5% / 50Hz ±0.5% Output frequency Pure sine wave <4%THD Pure sine wave <2%THD Output wave form 88% 89% 88% 87% 88% 87% Efficiency (full load) <5W <4W (in power saving status) No load power consumption 10~16VDC / 20~32VDC Input voltage range <10W in stand-by mode; >10W working mode Auto load detector ≤10.5VDC Disconnection ≥12VDC Reconnection Disconnection if DC input voltage is 16VDC Anti-surge protection Over / under input voltage, over temperature and reverse input polarity (fuse). Protection feature Over load, short circuit, shutdown, restart. Models Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 090709 1 PSI series Pure Sinusoidal Inverter General Data PSI 0150 12 x x PSI 0300 12 x x PSI 0600 12 x x PSI 1000 12 x x PSI 1500 12 x x PSI 3000 12 x x PSI 0150 24 x x PSI 0300 24 x x PSI 0600 24 x x PSI 1000 24 x x PSI 1500 24 x x PSI 3000 24 x x N/A 1 second Power saving recovery time Power ON/OFF, RUN/STAND-BY, High/Low battery shutdown, RUN, TRIP, LED All-in-one. LED status indication Over temperature shutdown and Over load shutdown. Models N/A Remote controller Operation temperature range Storage temperature range Power output ON/OFF, RUN, TRIP LED All-in-one -20°...+50°C / -4°...+122°F -30°...+70°C / -22°...+158°F Dimensions H W L Models Dimensions (LxWxH) mm PSI 0150 12 x x PSI 0300 12 x x PSI 0600 12 x x PSI 1000 12 x x PSI 1500 12 x x PSI 3000 12 x x PSI 0150 24 x x PSI 0300 24 x x PSI 0600 24 x x PSI 1000 24 x x PSI 1500 24 x x PSI 3000 24 x x 220x130x90 240x285x120 350x285x120 450x285x120 380x285x185 510x285x185 Features Over voltage LED Over temp LED The over voltage indicator indicates that the power inverter has shut itself down because its input voltage higher than the detect voltage (12V/24V/48VDC versions.) The over temp indicator indicates that the power inverter has shut down because it has become overheated. The power inverter may overheat because it has been operated at power levels above its rating, or because it has been installed in a location which does not allow it to dissipate heat properly. The power inverter will restart automatically once it has cooled off. Under voltage LED Overload LED The under voltage indicator indicates that the power inverter has shut itself down because its input voltage has been lower than detect voltage (12V/24V/48VDC versions.) The overload indicator indicates that the power inverter has shut itself down because its output circuit has been short circuited or drastically overloaded. Switch the ON/OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON. Power Saving Adjustment Automatic load-sensing, which allows the inverter to wait in Standby mode until an AC load is switched ON. When an AC load appears, the inverter will immediately start. This feature conserves valuable battery energy as the inverter uses only about 10% of normal power when in standby mode (standby is indicated by flashing green lamp). The amount of AC power is required to start the inverter can be adjusted. 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales 090709.