Optima 360 Series Hydrostatic level transmitter.
The 'Optima' series uses the established measurement principle of pressure sensitive
diaphragm and LVDT. Our unparalleled experience in the use of this technology over
many thousands of applications results in a transmitter capable of performing accurately
and reliably in the most demanding and arduous duties.
Diaphragms are provided in a choice of corrosion resistant alloys and are offered in a
number of “nominal” ranges, each engineered for optimum performance on it’s
measurement span. Diaphragm travel is limited by mechanical design, providing
unmatched tolerance to high overload and shock conditions.
Production employs TIG fusion technology and Mass Spectrometry analysis to ensure
complete integrity of all welded joints. A process of thermal ‘ageing’ is used for stress
relief and to ensure long-term stability in service.
Submersible construction is standard and the sensor may be free standing , suspended,
clamped or pole mounting within the vessel. For external mounting, any standard flange or thread may
·
·
·
·
·
Submersible construction
Where the application demands, automatic
EEXia IIC T5 certified option
compensation for both process and ambient
Complies with RFI / EMC Standards
temperature fluctuations can be built in.
Fully Welded Construction
For enhanced reliability and stability, all active
Superior Low Range Sensitivity /
electronics are remotely sited in a weatherproof
Accuracy
· Unrivalled Overload Tolerance
· Applications in oils, chemicals,
effluent, viscous fluids, sludges,
Water, open channel flow, etc.
enclosure, which, for ease of adjustment, contains all
calibration controls.
This electronics module meets current IEC standards
for RFI/EMC immunity, and is available certified I.S.
STANDARD SPECIFICATIONS
Calibrated Spans:
From 300mm to 32mH2O
Sensor cable:
Heavy duty TPE vented
Range adjustment:
30 to 100% of nominal
diaphragm range
Electronics housing:
Zero adjustment:
+/- 10% of span
Sensor operating temp.:
Overload:
Minimum 5 x nominal range
Output signal:
4 to 20 mA dc 2 wire
Electronics operating
temp.:
Electronics min survival:
IP65 GRP (NEMA 4) with
internal RFI screen
(IP67 optional)
-25 to +95oC
(optional -80/+150oC)
-40 to +55oC
Power requirement:
12 to 30Vdc (loop powered)
Temperature effect:
Maximum output load:
1000 ohms @ 30V
Accuracy:
Less than 0.05% / oC range
and zero
(0.02% / oC optional)
Better than 0.25% FRO
Sensor body:
316L st stl
Diaphragm:
Hastelloy C276 standard
-50 oC
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
Optima 360 Series Hydrostatic level transmitter.
Sample of the fitting options available
F1
Basic submersible sensor
F15
F2
DN25 PN16flange mounting
F16
F3
Tank fixing clamp
F17
Welded pole assembly 1 metre of pole
included
Running nut connection 3/4" BSP female
with NRVU plunger
DN40 PN16 flange mounting
F4
Pole adaptor fitting threaded 1/2" BSP
female
Threaded process connection 1/2" BSP
male
1" ANSI 150lb flange mounting to BS1560
F18
DN50 PN16 flange mounting
F19
Tank fixing clamp & Pole adaptor
F21
Body with slip flange location
F22
F8
Threaded process connection 1/2" NPT
male
Running nut connection 3/4" BSP female
F9
Free Standing
F24
Threaded process connection 1” BSP
female.
Threaded adaptor to allow fitting int
existing series 200 DN40 flange
Threaded adaptor to allow fitting int
existing series 200 DN50 flange
.2” BSP parallel thread for fixing to a
standard 25mm depth socket
F5
F6
F7
F10 Free standing with Pole adaptor fitting
threaded 1/2" BSP fem
F23
F25
plus others....please refer if your requirement is not listed
Typical Outline dimensions
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
400 Series Liquid level and pressure transmitter.
· Chemicals & Oils
· Water & Effluents
· Food & Beverage
· Pharmaceutical
· Marine / Shipboard
· Gauge and Absolute
· DIN electrical connector
with submersible option
A compact and mass optimized design with a choice of corrosion resistant materials together with a wide choice of
standard process connection options, make the
series 400 range of 2 wire transmitters the
ideal choice for simple application in many
industries.
·
·
·
·
The integral amplifier provides a direct 4 - 20
Spans from 10 mbar to 400 bar
Rugged reliable construction
High shock & overload tolerance
flanged, threaded and sanitary
fittings
mA output and features full zero and span user
calibration facility.
A unique sensor technology incorporates a precision diaphragm with nesting backplate affording exceptional
STANDARD SPECIFICATIONS
Body:
316 stainless steel
Diaphragm:
Supply:
Hastelloy C276 or 17-4PH st.
steel or inconel X750
Electron Beam and Pulsed
Arc Tig Fusion
2 wire 9 to 32V DC
Signal Output:
4 - 20 mA DC
Load:
LW =(Supply volts - 9) / 0.02
Connection:
Standard Din plug, optional
sealed cable for submersible
applications
±10% of nominal
Assembly:
Zero adjustment:
Span
adjustment:
Protection:
3 to 1 turndown of nominal
Humidity:
to IP65 / NEMA 4X ( with vented
signal cable )
0 - 100 % non condensing
Process temp:
-20 to 100°C / - 5 to 212°F
Maximum
error:
Temp effect:
± 0.25% T.S.L
Overload:
less than 0.02% FS / °C 0.011 %
FS / °F
Min. 10x nominal up to 50m
Min. 5x nominal up to 30Bar
Min. 2x nominal above 30Bar
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
400 Series Liquid level and pressure transmitter.
400G
400A
400GS
400AS
Gauge Pressure Transmitter 316 St. Stl. body with integral amplifier
Absolute Pressure Transmitter 316 St. Stl. body with integral amplifier
Gauge transmitter,316 St. Stl. body with integral amplifier & liquid tight cable exit
Absolute transmitter, 326 St. Stl. body with integral amplifier & liquid tight cable exit
T2
T3
T5
T6
T7
T11
T12
T13
T14
T18
T22
DN25 PN16 flange mounting
Tank fixing clamp SG
- & SA models only
Threaded process connection
1/2” BSP male
1” ANSI 150lb flange
mounting to BS1560
Threaded process connection
1/2” NPT male
Hygienic 2” IDF
Hygienic 2” RJT
Hygienic 2” Triclover
Hygienic 2”
SMS
DN50 PN16 flange
mounting
1” BSP female
H
S
0.5m H2O (1.5 ft WC)
1m H2O (3 ft WC)
2m H2O (6 ft WC)
4m H2O (12 ft WC)
8m H2O (26 ft WC)
16m H2O (52 ft WC)
32m H2O (105 ft WC)
50m H2O (164 ft WC)
—
H
Hygienic DIN 50mm to 11851
1/2” BSP female
1/4” BSP female
1/4” NPT female
1/2” NPT female
3/4” NPT female
1” NPT female
1/4” NPT male
1/4” BSP male
3/4” BSP female
2” ANSI 150lb flange
Hastelloy C Diaphragm - Ranges 0.5 m Wg to 50 m Wg
PH15/7 Stainless Steel Diaphragm- Ranges 10 bar to 400 bar G
Note : 10 bar & 20 bar diaphragms are convoluted , above 20 bar a flat plate machined
0.5
1
2
4
8
16
32
50
400A / T5 /
T31
T32
T33
T36
T38
T39
T40
T41
T42
T43
T44
10b
20b
40b
100b
200b
300b
400b
10 bar G (145 psig)
20 bar G (290 psig)
40 bar G (580 psig)
100 bar G (1450 psig)
200 bar G (2900 psig)
300 bar G (4350 psig)
400 bar G (5800 psig)
Specify set range in Metres H20
100b / 0 to 75 Bar
General outline
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
460 series liquid level transmitters for the marine industry
With many thousands of transmitters installed on all classes of
Ships from Military vessels to Tankers, the design of the
‘Tankstar’ series draws on over 20 years successful application
experience. Fully compliant with the latest IEC and Marine Industry
standards, its rugged construction provides reliable and accurate
monitoring of liquid levels in the harsh environments of shipboard
tanks and draught applications, where conditions of high overload,
shock, vibration, and temperature variation are common.
The measuring principle of pressure sensitive diaphragm &
L.V.D.T combines excellent sensitivity and long term stability The
‘Tankstar’ has the sensitivity needed to accurately measure
shallow tanks but will sustain a 50 times overload without damage.The all welded sensor is
manufactured from high grade alloys selected for their stability & corrosion resistance. A wide choice
of fittings and the remotely mounted amplifier maximises installation flexibility and serviceability.
· Sealed & submersible sensor
construction
· meets RFI/EMC standards
· Marine classification “Type Approved”
· Seawater, Oils & corrosive / hazardous
duties
· Versatile installation
· Gauge or absolute versions
· EExia IIC T5 intrinsically safe option
Sensors are maintenance free and contain no active
electronic components. A factory sealed cable is supplied
to the required length for direct connection to the amplifier.
The standard sensor cable has a heavy duty outer sheath
of cross linked polymers which are suitable for continuous
immersion in both sea water, fuels and hydrocarbons. An
optional performance cable permits use of sensor in
extreme temperature limits of -50°C to +150°C .
STANDARD SPECIFICATIONS
Calibrated spans:
From 0 - 300mm H2 O
to 0 - 100m H2 O
3:1 turndown of normal range
± 10% of calibrated span
Diaphragms:
Hastelloy C276
Sensor cable:
Electronics housing:
Operating temperature:
Signal output:
Power supply:
Maximum load:
Minimum of 50 metres or 5 x
nominal range
1, 2, 4, 8, 16, 32, 50, 100
metres H2 O
4 -20mA DC 2 wire
12 - 30V DC
1000 ohms at 30V
Heavy duty TPE vented
IP65 GRP (NEMA 4) with
internal RFI screen
(IP67 optional)
-25°C to +95°C
(option: -80 to 150°C)
-40 to +55°C
Sensor body:
316L stainless steel
Range adjustment:
Zero adjustment:
Overload:
Nominal ranges:
Electronics op.temp:
Minimum survival:
Accuracy:
Temp. coefficient:
-50°C
Better than ±0.25% FRO
Less than 0.02% per °C shift
zero and range
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
460 series liquid level transmitters for the marine industry
460
Hydrostatic Sensor in 316 St. Stl. c/w 3 metres of cable RT168A 4 to 20 mA amplifier
F47
F2
F3
F4
F5
F6
Basic submersible sensor with drain wire adaptor
DN25 PN16 flange mounting
Tank fixing clamp
Pole adaptor fitting threaded 1/2” BSP female
Threaded process connection 1/2” BSP male
1” ANSI 150lb flange mounting to BS1560
F7
F8
F15
F16
F17
F18
F19
1/2” NPT male
3.4” BSP female
Welded pole assembly
3.4” BSP female with NRVU plunger
DN40 PN16 flange mounting
DN50 PN16 flange mounting
1/2” BSP female
Hastelloy Diaphragm
H
2D
4D
8D
16D
32D
50D
100D
200D
2m H2 O
4m H2 O
8m H2 O
16m H2 O
32m H2 O
50m H2 O
100m H2 O
200m H2 O
Nominal
range in
metres H2O
Hytrel TPE heavy duty vented cable
P
Cable length in metres
Drain wire length in metres (F47 model only)
-DW- -
--
Transmitter set range in metres H2 O
IS
Intrinsically safe certified
Intrinsically safety not required
Other options include:
B-High temperature sensor(up to 120o C submersible versions, 145o C external versions) G-IP67 Amplifier enclosure
K-Absolute pressure version LG-Bulkhead fitting in CS (B211B) LGS-Bulkhead fitting in SS(B211A)
9-PG9 gland for signal cable (Standard) 13-PG13.5 16-PG16
191mm
76mm
OPTIONAL POLE
& TOP FLANGE ASSEMBLY
75mm
REMOTE MOUNTED
AMPLIFIER
IP65 / 1P67
OPTIONAL BULKHEAD
PENETRATION GLAND
PG9 SENSOR
CABLE GLAND
SENSOR
DRAIN WIRE
PG9 SINTERED
BREATHER
GLAND
SIGNAL CABLE GLAND
PG9, 11, 13.5.
PVDF PIPE
50/75mm ID
4-20mA
2 WIRE OUTPUT
OPTIONALLY USED
FOR PIPING TO
VENTED AREA
STRAPPING
CABLE CLIPPED
TO TANK
OR RUN IN
CONDUIT
CABLE SUSPENDED
SENSOR. F47
END STOP
THREADED SENSORS.
F5, F7, F8, F16, F19.
POLE MOUNTING
SENSOR.
F4, F15.
TANK FIXING CLAMP
ISOLATION VALVE
(OPTIONAL)
FLANGE MOUNTED
SENSORS.
F2, F6, F17, F18.
ISOLATION VALVE
(OPTIONAL)
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
Series 290 Density Transmitter
Features
!
!
!
!
!
!
!
!
Basic design is readily adapted to suit each
application
Submersible or external tank mounting
Stainless steel body and Hastelloy diaphragms
permit application on many aggressive chemicals
2 wire 4 to 20 mA output from remote
weatherproof amplfier module
Intrinsically safe versions available
Suitable for Densities in the range 0.5 to 3.00 and
may be calibrated with offset zero
Optional temperature compensation for
applications where ambient shift is significant
Protected against conditions of asymetric
overload
NASC 290 Series transmitters measure density as a function of differential pressure. Each
unit has two pressure sensitive diaphragms, each of which are located at a known elevation
in the tank. Under normal operation both diaphragms will be submerged, and since the
distance between them is fixed, any variation in the pressure differential between them
must be a function of the liquid density.
Within the sensor construction the diaphragms are hydraulically linked, the lower
diaphragm is “rated” to suit the density span while the upper is compliant and provides a
pressure transfer, via the hydraulic fill, to the rear of the rated diaphragm. Actual
displacement of the lower diaphragm is measured using the proven LVDT principle. An
amplifier module receives the LVDT’s output signal and conditions it to provide a 4 to 20
mA output over the required span. For convenience this amplifier may be sited up to 100
Meters away from the sensor. NASC’s unrivaled experience in the design and application of
pressure sensitive diaphragms and a versatile approach to unit construction, ensures
optimum performance on all applications. Examples of previous successes include duties as
diverse as Beer fermentation vessels, where very small changes in density must be resolved
and hygienic construction is needed, and Drilling Mud storage vessels where mechanical
protection and rugged construction are essential.
Units can be manufactured to suit either external flanged, threaded, or hygienic fittings, or
as a completely submersible unit suitable for pole suspension or clamping in place.
1-800-259-6874
23400 Hwy. 435 Abita Springs, LA. 70420
Series 290 Density Transmitter
SENSOR
Construction
Fluid fill
Operating temperature:
Temperature compensation:
Body assembly 316L stainless Steel
Diaphragms Hastelloy C276
External flanged or threaded, or internal
submersed
Density span 0.5 to 3.00
with zero offset to suit application
Silicon or Mineral oil.
-10 to +80° C
As required by application
AMPLIFIER MODULE
Construction
Enclosure rating:
Power supply:
Signal output:
Wall mount GRP enclosure
IP65 (IP67 option) / NEMA 4X
12 to 30 Vdc
4 to 20 mA dc, 2 wire.
Mounting
Range:
PERFORMANCE
Accuracy:
Temperature coefficient
OPTIONS
Intrinsically safe unit available
+/-0.25% of set span
+/- 0.01% set span/°C range & zero
(compensated unit)
To EEx ia IIC T6
Typical Construction
The 290 is a registered design. All rights reserved 1998