Data Sheets - North American Sensors
Transcription
Data Sheets - North American Sensors
Optima 360 Series Hydrostatic level transmitter. The 'Optima' series uses the established measurement principle of pressure sensitive diaphragm and LVDT. Our unparalleled experience in the use of this technology over many thousands of applications results in a transmitter capable of performing accurately and reliably in the most demanding and arduous duties. Diaphragms are provided in a choice of corrosion resistant alloys and are offered in a number of “nominal” ranges, each engineered for optimum performance on it’s measurement span. Diaphragm travel is limited by mechanical design, providing unmatched tolerance to high overload and shock conditions. Production employs TIG fusion technology and Mass Spectrometry analysis to ensure complete integrity of all welded joints. A process of thermal ‘ageing’ is used for stress relief and to ensure long-term stability in service. Submersible construction is standard and the sensor may be free standing , suspended, clamped or pole mounting within the vessel. For external mounting, any standard flange or thread may · · · · · Submersible construction Where the application demands, automatic EEXia IIC T5 certified option compensation for both process and ambient Complies with RFI / EMC Standards temperature fluctuations can be built in. Fully Welded Construction For enhanced reliability and stability, all active Superior Low Range Sensitivity / electronics are remotely sited in a weatherproof Accuracy · Unrivalled Overload Tolerance · Applications in oils, chemicals, effluent, viscous fluids, sludges, Water, open channel flow, etc. enclosure, which, for ease of adjustment, contains all calibration controls. This electronics module meets current IEC standards for RFI/EMC immunity, and is available certified I.S. STANDARD SPECIFICATIONS Calibrated Spans: From 300mm to 32mH2O Sensor cable: Heavy duty TPE vented Range adjustment: 30 to 100% of nominal diaphragm range Electronics housing: Zero adjustment: +/- 10% of span Sensor operating temp.: Overload: Minimum 5 x nominal range Output signal: 4 to 20 mA dc 2 wire Electronics operating temp.: Electronics min survival: IP65 GRP (NEMA 4) with internal RFI screen (IP67 optional) -25 to +95oC (optional -80/+150oC) -40 to +55oC Power requirement: 12 to 30Vdc (loop powered) Temperature effect: Maximum output load: 1000 ohms @ 30V Accuracy: Less than 0.05% / oC range and zero (0.02% / oC optional) Better than 0.25% FRO Sensor body: 316L st stl Diaphragm: Hastelloy C276 standard -50 oC 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 Optima 360 Series Hydrostatic level transmitter. Sample of the fitting options available F1 Basic submersible sensor F15 F2 DN25 PN16flange mounting F16 F3 Tank fixing clamp F17 Welded pole assembly 1 metre of pole included Running nut connection 3/4" BSP female with NRVU plunger DN40 PN16 flange mounting F4 Pole adaptor fitting threaded 1/2" BSP female Threaded process connection 1/2" BSP male 1" ANSI 150lb flange mounting to BS1560 F18 DN50 PN16 flange mounting F19 Tank fixing clamp & Pole adaptor F21 Body with slip flange location F22 F8 Threaded process connection 1/2" NPT male Running nut connection 3/4" BSP female F9 Free Standing F24 Threaded process connection 1” BSP female. Threaded adaptor to allow fitting int existing series 200 DN40 flange Threaded adaptor to allow fitting int existing series 200 DN50 flange .2” BSP parallel thread for fixing to a standard 25mm depth socket F5 F6 F7 F10 Free standing with Pole adaptor fitting threaded 1/2" BSP fem F23 F25 plus others....please refer if your requirement is not listed Typical Outline dimensions 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 400 Series Liquid level and pressure transmitter. · Chemicals & Oils · Water & Effluents · Food & Beverage · Pharmaceutical · Marine / Shipboard · Gauge and Absolute · DIN electrical connector with submersible option A compact and mass optimized design with a choice of corrosion resistant materials together with a wide choice of standard process connection options, make the series 400 range of 2 wire transmitters the ideal choice for simple application in many industries. · · · · The integral amplifier provides a direct 4 - 20 Spans from 10 mbar to 400 bar Rugged reliable construction High shock & overload tolerance flanged, threaded and sanitary fittings mA output and features full zero and span user calibration facility. A unique sensor technology incorporates a precision diaphragm with nesting backplate affording exceptional STANDARD SPECIFICATIONS Body: 316 stainless steel Diaphragm: Supply: Hastelloy C276 or 17-4PH st. steel or inconel X750 Electron Beam and Pulsed Arc Tig Fusion 2 wire 9 to 32V DC Signal Output: 4 - 20 mA DC Load: LW =(Supply volts - 9) / 0.02 Connection: Standard Din plug, optional sealed cable for submersible applications ±10% of nominal Assembly: Zero adjustment: Span adjustment: Protection: 3 to 1 turndown of nominal Humidity: to IP65 / NEMA 4X ( with vented signal cable ) 0 - 100 % non condensing Process temp: -20 to 100°C / - 5 to 212°F Maximum error: Temp effect: ± 0.25% T.S.L Overload: less than 0.02% FS / °C 0.011 % FS / °F Min. 10x nominal up to 50m Min. 5x nominal up to 30Bar Min. 2x nominal above 30Bar 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 400 Series Liquid level and pressure transmitter. 400G 400A 400GS 400AS Gauge Pressure Transmitter 316 St. Stl. body with integral amplifier Absolute Pressure Transmitter 316 St. Stl. body with integral amplifier Gauge transmitter,316 St. Stl. body with integral amplifier & liquid tight cable exit Absolute transmitter, 326 St. Stl. body with integral amplifier & liquid tight cable exit T2 T3 T5 T6 T7 T11 T12 T13 T14 T18 T22 DN25 PN16 flange mounting Tank fixing clamp SG - & SA models only Threaded process connection 1/2” BSP male 1” ANSI 150lb flange mounting to BS1560 Threaded process connection 1/2” NPT male Hygienic 2” IDF Hygienic 2” RJT Hygienic 2” Triclover Hygienic 2” SMS DN50 PN16 flange mounting 1” BSP female H S 0.5m H2O (1.5 ft WC) 1m H2O (3 ft WC) 2m H2O (6 ft WC) 4m H2O (12 ft WC) 8m H2O (26 ft WC) 16m H2O (52 ft WC) 32m H2O (105 ft WC) 50m H2O (164 ft WC) — H Hygienic DIN 50mm to 11851 1/2” BSP female 1/4” BSP female 1/4” NPT female 1/2” NPT female 3/4” NPT female 1” NPT female 1/4” NPT male 1/4” BSP male 3/4” BSP female 2” ANSI 150lb flange Hastelloy C Diaphragm - Ranges 0.5 m Wg to 50 m Wg PH15/7 Stainless Steel Diaphragm- Ranges 10 bar to 400 bar G Note : 10 bar & 20 bar diaphragms are convoluted , above 20 bar a flat plate machined 0.5 1 2 4 8 16 32 50 400A / T5 / T31 T32 T33 T36 T38 T39 T40 T41 T42 T43 T44 10b 20b 40b 100b 200b 300b 400b 10 bar G (145 psig) 20 bar G (290 psig) 40 bar G (580 psig) 100 bar G (1450 psig) 200 bar G (2900 psig) 300 bar G (4350 psig) 400 bar G (5800 psig) Specify set range in Metres H20 100b / 0 to 75 Bar General outline 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 460 series liquid level transmitters for the marine industry With many thousands of transmitters installed on all classes of Ships from Military vessels to Tankers, the design of the ‘Tankstar’ series draws on over 20 years successful application experience. Fully compliant with the latest IEC and Marine Industry standards, its rugged construction provides reliable and accurate monitoring of liquid levels in the harsh environments of shipboard tanks and draught applications, where conditions of high overload, shock, vibration, and temperature variation are common. The measuring principle of pressure sensitive diaphragm & L.V.D.T combines excellent sensitivity and long term stability The ‘Tankstar’ has the sensitivity needed to accurately measure shallow tanks but will sustain a 50 times overload without damage.The all welded sensor is manufactured from high grade alloys selected for their stability & corrosion resistance. A wide choice of fittings and the remotely mounted amplifier maximises installation flexibility and serviceability. · Sealed & submersible sensor construction · meets RFI/EMC standards · Marine classification “Type Approved” · Seawater, Oils & corrosive / hazardous duties · Versatile installation · Gauge or absolute versions · EExia IIC T5 intrinsically safe option Sensors are maintenance free and contain no active electronic components. A factory sealed cable is supplied to the required length for direct connection to the amplifier. The standard sensor cable has a heavy duty outer sheath of cross linked polymers which are suitable for continuous immersion in both sea water, fuels and hydrocarbons. An optional performance cable permits use of sensor in extreme temperature limits of -50°C to +150°C . STANDARD SPECIFICATIONS Calibrated spans: From 0 - 300mm H2 O to 0 - 100m H2 O 3:1 turndown of normal range ± 10% of calibrated span Diaphragms: Hastelloy C276 Sensor cable: Electronics housing: Operating temperature: Signal output: Power supply: Maximum load: Minimum of 50 metres or 5 x nominal range 1, 2, 4, 8, 16, 32, 50, 100 metres H2 O 4 -20mA DC 2 wire 12 - 30V DC 1000 ohms at 30V Heavy duty TPE vented IP65 GRP (NEMA 4) with internal RFI screen (IP67 optional) -25°C to +95°C (option: -80 to 150°C) -40 to +55°C Sensor body: 316L stainless steel Range adjustment: Zero adjustment: Overload: Nominal ranges: Electronics op.temp: Minimum survival: Accuracy: Temp. coefficient: -50°C Better than ±0.25% FRO Less than 0.02% per °C shift zero and range 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 460 series liquid level transmitters for the marine industry 460 Hydrostatic Sensor in 316 St. Stl. c/w 3 metres of cable RT168A 4 to 20 mA amplifier F47 F2 F3 F4 F5 F6 Basic submersible sensor with drain wire adaptor DN25 PN16 flange mounting Tank fixing clamp Pole adaptor fitting threaded 1/2” BSP female Threaded process connection 1/2” BSP male 1” ANSI 150lb flange mounting to BS1560 F7 F8 F15 F16 F17 F18 F19 1/2” NPT male 3.4” BSP female Welded pole assembly 3.4” BSP female with NRVU plunger DN40 PN16 flange mounting DN50 PN16 flange mounting 1/2” BSP female Hastelloy Diaphragm H 2D 4D 8D 16D 32D 50D 100D 200D 2m H2 O 4m H2 O 8m H2 O 16m H2 O 32m H2 O 50m H2 O 100m H2 O 200m H2 O Nominal range in metres H2O Hytrel TPE heavy duty vented cable P Cable length in metres Drain wire length in metres (F47 model only) -DW- - -- Transmitter set range in metres H2 O IS Intrinsically safe certified Intrinsically safety not required Other options include: B-High temperature sensor(up to 120o C submersible versions, 145o C external versions) G-IP67 Amplifier enclosure K-Absolute pressure version LG-Bulkhead fitting in CS (B211B) LGS-Bulkhead fitting in SS(B211A) 9-PG9 gland for signal cable (Standard) 13-PG13.5 16-PG16 191mm 76mm OPTIONAL POLE & TOP FLANGE ASSEMBLY 75mm REMOTE MOUNTED AMPLIFIER IP65 / 1P67 OPTIONAL BULKHEAD PENETRATION GLAND PG9 SENSOR CABLE GLAND SENSOR DRAIN WIRE PG9 SINTERED BREATHER GLAND SIGNAL CABLE GLAND PG9, 11, 13.5. PVDF PIPE 50/75mm ID 4-20mA 2 WIRE OUTPUT OPTIONALLY USED FOR PIPING TO VENTED AREA STRAPPING CABLE CLIPPED TO TANK OR RUN IN CONDUIT CABLE SUSPENDED SENSOR. F47 END STOP THREADED SENSORS. F5, F7, F8, F16, F19. POLE MOUNTING SENSOR. F4, F15. TANK FIXING CLAMP ISOLATION VALVE (OPTIONAL) FLANGE MOUNTED SENSORS. F2, F6, F17, F18. ISOLATION VALVE (OPTIONAL) 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 Series 290 Density Transmitter Features ! ! ! ! ! ! ! ! Basic design is readily adapted to suit each application Submersible or external tank mounting Stainless steel body and Hastelloy diaphragms permit application on many aggressive chemicals 2 wire 4 to 20 mA output from remote weatherproof amplfier module Intrinsically safe versions available Suitable for Densities in the range 0.5 to 3.00 and may be calibrated with offset zero Optional temperature compensation for applications where ambient shift is significant Protected against conditions of asymetric overload NASC 290 Series transmitters measure density as a function of differential pressure. Each unit has two pressure sensitive diaphragms, each of which are located at a known elevation in the tank. Under normal operation both diaphragms will be submerged, and since the distance between them is fixed, any variation in the pressure differential between them must be a function of the liquid density. Within the sensor construction the diaphragms are hydraulically linked, the lower diaphragm is “rated” to suit the density span while the upper is compliant and provides a pressure transfer, via the hydraulic fill, to the rear of the rated diaphragm. Actual displacement of the lower diaphragm is measured using the proven LVDT principle. An amplifier module receives the LVDT’s output signal and conditions it to provide a 4 to 20 mA output over the required span. For convenience this amplifier may be sited up to 100 Meters away from the sensor. NASC’s unrivaled experience in the design and application of pressure sensitive diaphragms and a versatile approach to unit construction, ensures optimum performance on all applications. Examples of previous successes include duties as diverse as Beer fermentation vessels, where very small changes in density must be resolved and hygienic construction is needed, and Drilling Mud storage vessels where mechanical protection and rugged construction are essential. Units can be manufactured to suit either external flanged, threaded, or hygienic fittings, or as a completely submersible unit suitable for pole suspension or clamping in place. 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420 Series 290 Density Transmitter SENSOR Construction Fluid fill Operating temperature: Temperature compensation: Body assembly 316L stainless Steel Diaphragms Hastelloy C276 External flanged or threaded, or internal submersed Density span 0.5 to 3.00 with zero offset to suit application Silicon or Mineral oil. -10 to +80° C As required by application AMPLIFIER MODULE Construction Enclosure rating: Power supply: Signal output: Wall mount GRP enclosure IP65 (IP67 option) / NEMA 4X 12 to 30 Vdc 4 to 20 mA dc, 2 wire. Mounting Range: PERFORMANCE Accuracy: Temperature coefficient OPTIONS Intrinsically safe unit available +/-0.25% of set span +/- 0.01% set span/°C range & zero (compensated unit) To EEx ia IIC T6 Typical Construction The 290 is a registered design. All rights reserved 1998 1-800-259-6874 23400 Hwy. 435 Abita Springs, LA. 70420