pocket guide - AO Smith Water Heaters

Transcription

pocket guide - AO Smith Water Heaters
FULL PRODUCT LINE
POCKET GUIDE
RESIDENTIAL & COMMERCIAL
The story is all in the details. Every water heater that carries the
A. O. Smith name has a reputation to live up to, one that we’ve
earned through 140 years of innovation. As an industry leader, we
constantly look for new materials and develop new technologies that
can improve energy efficiency. So, when you choose an A. O. Smith
water heater, whether it’s gas, electric or hybrid you can be confident
that you are getting the best water heating solution regardless of
the application —for today and for years to come. Innovation has a
name... A. O. Smith.
All A. O. Smith residential water heaters meet the Federal Energy Efficiency Standards
effective April 16, 2015, according to the National Appliance Energy Conservation Act
(NAECA) of 1992 and meet the thermal efficiency and standby loss requirements of the
U. S. Department of Energy and current edition of ASHRAE/IESNA 90.1. They also comply
with the current edition of ICC Codes and the HUD Standards. Gas models meet American
National Standards Institute Standards (ANSI Z21.10.3 - CSA 4.1) governing storage-type
water heaters. Electric models are UL listed according to safety specifications outlined in
Underwriters Laboratories, Inc. Standards for Safety (UL 174).
RESIDENTIAL TABLE OF CONTENTS
COMMERCIAL TABLE OF CONTENTS
NAECA III Transition...........................................................................1
REMOTE MONITORING SYSTEM
Contractor Rewards Program™..........................................................2
iCOMM™ and iCOMM™ Elite......................................................62-63
Product Comparison Guide................................................................3
BUILDING MANAGEMENT SYSTEM
RESIDENTIAL GAS
BACnet and Modbus Interface....................................................64-65
Vertex™ High Efficiency Power Vent................................................4-5
COMMERCIAL GAS AND OIL FIRED
Vertex™ High Efficiency Power Direct Vent......................................6-7
Cyclone® HE BTX-80...................................................................66-67
Non-Condensing Power Vent..........................................................8-9
Cyclone® Xi BTX-100...................................................................68-69
Non-Condensing Power Direct Vent............................................10-11
Cyclone® Xi BTXL-100.................................................................70-71
ProMax® Direct Vent...................................................................12-13
Cyclone® MXi..............................................................................72-75
Effex High Efficiency Atmospheric Vent.....................................14-15
Master-Fit® BTR...........................................................................76-79
High Efficiency Non-Condensing Flue Damper............................16-17
Master-Fit® BTR Booster ............................................................80-81
®
ProMax Atmospheric Vent.........................................................18-21
Master-Fit® Ultra-Low NOx.........................................................82-85
ProMax® High Recovery Atmospheric Vent
Conservationist® BT....................................................................86-87
75 & 100 Gallon..........................................................................22-23
Induced Draft Low NOx BTN Power Vent....................................88-89
Energy Saver Atmospheric Vent...................................................24-25
Conservationist® Power Vent......................................................90-91
Energy Saver Direct Vent ............................................................26-27
Conservationist® Power Direct Vent............................................92-93
ProMax® Ultra-Low NOx.............................................................28-29
Conservationist® Ultra-Low NOx.................................................94-95
High Efficiency Non-Condensing
Power Burner Light-Duty.............................................................96-97
Ultra-Low NOx Power Vent.........................................................30-31
Low NOx Power Burner...............................................................98-99
ProMax® Ultra-Low NOx Direct Vent...........................................32-33
Conservationist® High Volume Power Burner..........................100-103
ProMax® Ultra-Low NOx High Recovery.....................................34-35
Conservationist® Duraclad Oil-Fired Tank-Type........................104-105
RESIDENTIAL TANKLESS
Custom Heavy-Duty Large Volume Oil-Fired............................106-109
Tankless Condensing High Efficiency..........................................36-37
COMMERCIAL TANKLESS
®
Tankless Condensing High Efficiency..........................................38-39
Tankless Non-Condensing.......................................................110-111
Tankless Non-Condensing...........................................................40-41
Tankless Non-Condensing Ultra-Low NOx..............................112-113
Tankless Non-Condensing Ultra-Low NOx..................................42-43
Tankless Condensing High Efficiency......................................114-115
RESIDENTIAL HYBRID ELECTRIC
Tankless Heavy-Duty...............................................................116-117
Voltex® Hybrid Electric Heat Pump - 10-Year Warranty...............44-45
COMMERCIAL ELECTRIC
Voltex® Legacy Hybrid Electric Heat Pump..................................46-47
DEN/DEL Electric Dura-Power™...............................................118-119
Voltex Hybrid Electric Heat Pump - 6-Year Warranty.................48-49
Gold Xi Series - DVE Electric...................................................120-121
RESIDENTIAL ELECTRIC
Gold Series - DRE Electric........................................................122-123
Conservationist Self-Cleaning.....................................................50-51
Heavy-Duty Custom Xi............................................................124-125
ProMax® Standard......................................................................52-53
Heavy-Duty CMC/SU Booster Electric Dura-Power™................126-127
ProMax® Mobile Home...............................................................54-55
Air-To-Water Electric Heat Pumps ..........................................128-129
ProMax® Specialty......................................................................56-57
Heavy-Duty Premium Electric DVE/DHE Dura-Power™ ............130-133
RESIDENTIAL PUMP AND EXPANSION TANKS
XP Domestic Water Heaters ...................................................134-137
®
Pump Tanks.................................................................................58-59
Expansion Tanks .........................................................................60-61
COMMERCIAL TABLE OF CONTENTS
COMMERCIAL WATER HEATERS
Burkay®Genesis® Domestic Water Heater...............................138-139
GUIDING YOU THROUGH
Variable Fire™ High Efficiency Water Heater...........................140-141
THE NAECA III TRANSITION
HOT WATER SUPPLY BOILERS
Burkay® Energy Saver Copper Heat Exchanger......................142-143
Burkay® HW Gas Domestic Water Heaters & Boiler................144-145
COMMERCIAL ELECTRIC BOILERS
Dura-Power™ NW Electric Boiler.............................................146-149
HOT WATER GENERATOR
Steam or Boiler Hot Water HWG Generator Systems .............150-151
COMMERCIAL STORAGE TANKS
Standard Jacketed Storage Tank.............................................152-153
Custom-Line Factory Jacketed
& Insulated Storage Tank.......................................................154-155
Uninsulated Standard Stock Bare Storage Tank.....................156-157
Heavy-Duty Large Volume Storage Tanks
Model HD Custom Built.........................................................158-161
COMMERCIAL WATER HEATERS
The U.S. Department of Energy (DOE) regulates minimum energy efficiency
requirements for all brands of water heaters. A new update to the rules
for increasing minimum energy efficiency is in effect as of April 16, 2015.
AT A. O. SMITH, WE’VE PREPARED OUR
LINE OF RESIDENTIAL WATER HEATERS TO
MEET THE STANDARDS. BUT AS SOMEONE
IN THE BUILDING COMMUNITY, YOU NEED
TO UNDERSTAND HOW THESE CHANGES
IMPACT YOU AS WELL.
These design changes require that most residential water heaters under 55
gallons of capacity produced after April 16, 2015 be larger in size. Therefore, they
will require more installation space in both single-family and multi-family housing.
Most water heaters under 55 gallons are 2˝ larger in height and diameter. Units
over 55 gallons will require even more drastic technology changes.
WATER HEATER REPLACEMENT ISSUES?
WE HAVE SOLUTIONS.
AC-U-Temp Complete Hot Water Systems.....................................162
OPTION 2: Upgrade to a smaller more efficient tankless unit.
THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS
CHANGED.
MORE
OPTION 1: Upgrade to one of A. O . Smith’s High Efficiency
THAN
Options such as tankless or Vertex®.
55
GALLON OPTION 2: Replace your obsolete model with 2 smaller gas
heaters. (Example: two 40-gallon gas units in the place of one
75-gallon gas unit).
ELECTRIC
Semi-Instantaneous HWI Water Heaters.......................................163
GAS
INSTANTANEOUS
WILL THE NEW LARGER DESIGN FIT? IF NOT, YOU
HAVE TWO OPTIONS.
LESS
OPTION 1: Use a smaller heater to match the current footprint of
THAN
your existing heater. You might consider adding a mixing valve on
55
GALLON the water heater to increase delivery capacity.
WILL THE NEW LARGER DESIGN FIT? IF NOT,SEE
LESS
BELOW.
THAN
OPTION 1: Use a smaller heater to match the current footprint
55
GALLON of your existing heater. You might consider adding a mixing valve
on the water heater to increase delivery capacity.
THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS
CHANGED.
MORE
OPTION 1: Upgrade to A. O. Smith’s Voltex® Hybrid Electric
THAN
Heat Pump water heater which is 2.5x more efficient as a standard
55
GALLON electric.
OPTION 2: Replace your obsolete model with 2 smaller electric
heaters (Example: Two 40-gallon electrics in the place of one
80-gallon electric).
TO LEARN MORE, VISIT HOTWATER.COM/NAECA
WHY PROFESSIONALS
A. O. SMITH WATER HEATERS
CHOOSE A. O. SMITH
Contractor
Rewards Program
Brand
Support
It’s free and easy to participate. Enroll
online at contractorrewards.com.
Eligible products will have a yellow
reward code label worth valuable
points. Two ways to enter the codes:
Profitable
Contractors
Contractor
Tools & Support
PREMIUM FEATURES.
NAECA III READY.
EARN POINTS BY
PURCHASING A. O.
SMITH WATER HEATERS
Contractor Locator
Breadth of
Product Line
1. Download the smart phone
app and scan the code.
2. Enter the code at
contractorrewards.com.
Redeem your points on
thousands of reward items.
Advertising
Resources
PROMAX PROMAX
®
®
CONSERVATIONIST
CONSERVATIONIST
CONSERVATIONIST
CONSERVATIONIST
PREFERREDPREFERRED
PROMAX
CONSERVATIONIST
CONSERVATIONIST PREFERRED
B E S TB E S T
®
®
®
®
G O O DG O O D
®
®
BETTE
BR
ETTER
GOOD
®
BETTER
BEST
OPERATING COST
CONSERVATIONALIST
CONSERVATIONALIST
CONSERVATIONIST
CONSERVATIONIST
PREFERREDPREFERRED
$$$$$
PROMAX
CONSERVATIONALIST
CONSERVATIONIST$
PREFERRED
PROMAX® PROMAX®
®
G O O D
G O O D
INSTALLATION SPACE REQUIRED n n
®
®
B E T TB
EE
RT T E R
G O O D
®
®
®
®
B E S TB E S T
B E T T E R
n to n n
B E S T
n to n n n
HOT WATER OUTPUT
®
®
CONSERVATIONALIST
CONSERVATIONALIST
®
CONSERVATIONALIST
CONSERVATIONALIST
®
P R E F E®PRRREEFDE R R E D CONSERVATIONALIST
CONSERVATIONALIST
PREFERRED
®
PROMAX® PROMAX®
PROMAX
PREMIUM FEATURES:
B E S TB E S T
Blue Diamond®
PROMAX PROMAX
Glass Coating**
•
®
WITH OVER 1,000,000 MERCHANDISE
ITEMS,YOUR REWARD CHOICES ARE ENDLESS.
Dynaclean™ Automatic
Sediment-Cleaning System**
A. O. SMITH PROVIDES 6 KEY THINGS
Heat Trap Nipples**
TO HELP GROW YOUR BUSINESS & BECOME MORE PROFITABLE
1. Contractor Locator
A new online locator that drives thousands of consumers from our website right
to our loyal contractors. Your company listing is free and generated for you when
you participate in our Contractor Rewards™ program.* Visit hotwater.com/
contractorlocator for more information.
2. Contractor Rewards Program
Our program rewards our loyal contractors for buying our products. Buy more and
get rewarded with prizes and higher status on our Contractor Locator.
3. Contractor Advertising Tools
Our Advertising Resource Center allows contractors to develop an easy, affordable
and custom advertising campaign to promote their business. Go to www.hotwater.
com/ads.
4. Breadth of Product Line
Residential or Commercial, we have the most complete line from Standard models
to the most innovative high efficiency water heaters available.
Self-Powered Electronic
Gas Valve*
Enhanced Flow Brass
Drain Valve**
Coregard™ Advanced
Anode Rod Protection**
Energy Saving
®
★ G O O ★DG★ O O D ★
•
B E T TBEERT T E R
B E S T
•
•
®
B E S TB E S T
B E T T E R
B E S T
•
•
®
®
CONSERVATIONALIST
CONSERVATIONALIST
®
CONSERVATIONALIST
CONSERVATIONALIST
P R E F E®PRRREEFDE R R E D CONSERVATIONALIST
PROMAX®
CONSERVATIONALIST
PREFERRED
★ B E T T★E
BR
E★T T E R ★
★G O O D★
®
★ B E S★TB★ E S T ★
★BETTER★
®
★B E S T★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Meets NAECA minimums Electronic User Interface
Condensing Combustion*
Continuous Flow*
Cutting Edge Technology
Industry Leading Efficiency
Applies to some products only
*These features apply to gas products only
**These features apply to tank-type products only
Hot Water Output, Cost of Operation, & Installation Space Required estimated based on typical
applications/installations. For a more custom analysis of unique installations, visit www.hotwater.com
and use our product selector tool.
5. Product Sales Tools
We provide contractors access to the sales tools needed to close more sales.
6. Brand Support
Marketing investment in our brands drive consumers to recognize our name, visit
our websites, locate local contractors and request products.
*To be listed on the Contractor Locator you must meet the minimum threshold of codes
entered at contractorrewards.com
2
Visit hotwater.com/contractor to learn more.
www.hotwater.com
3
RESIDENTIAL GAS
T & P VALVE
SIDE
OUTLET
H
VERTEX™ HIGH EFFICIENCY POWER VENT
ANODE
Power Vent Design for Installation
Versatility
• Modular blower, with 120 volt, 60Hz electrical
system (5 amps orA
less), 6-foot cord with standard
3-prong connector.
G
HOT
B
DIAMETER
• Combined horizontal and vertical vent runs
terminating through an outside wall, using Schedule
40 PVC pipe as follows:
SIDE INLET
K
COLD
J
C
TOP VIEW
• 2” pipe allows vent runs up to 25 equivalent feet.
• 3” pipe allows vent runs up toT65
equivalent feet.
HERMOSTAT
• 4” pipe allows vent runs up to 128 equivalent
feet.
* INSTALL IN ACCORDANCE WITH LOCAL CODES
DRAIN
VALVE
Side-Mounted Taps for Recirculating
F
Systems
• Hot and cold “side taps” allow Vertex Power Vent to
be used for “combination” systems for water heating
plus space heating, radiant floor heatingFRONT
or other VIEW
applications requiring a recirculating hot water loop.
D
OUTLET
INLET
E
SIDE
OUTLET
T & P VALVE
Intelli-vent™* Gas Control with Silicon
Nitride Hot Surface Ignitor
AN
• Premium-grade hot surface ignitor eliminates
standing pilot.
• Electronic circuitry provides superior system
diagnostics capabilities plus extremely precise
temperature control.
Blue Diamond® Glass Coating with Two
Heavy Duty Anode Rods
A
B
G
DIAMETER
• Provides superior corrosion resistance compared to
the industry-standard glass lining.
THERMOSTAT
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
Dynaclean™ Diffuser Dip Tube
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
4
*Intelli-Vent™ is a registered trademark of Emerson
Electric Company
D
E
FRONT VIEW
Maximum Hydrostatic Working
Pressure:150 PSI
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
* INSTALL
DRAIN
VALVE
F
CSA Certified and ASME Rated T&P Relief
Valve
• Meets UBC, CEC and ICC National Codes.
C
SIDE INLET
Green Choice® Gas Burner
Code Compliance
J
Model
Number
GPHE-50
Recovery @
BTU
First Hour
Gallon
90°F Rise Gallon
Input
Delivery
Capacity
Per Hour
Per Hour Gallons
50
92
76,000
Approx.
Shipping
Weight (lbs)
127
210
Dimensions in Inches
Model
Number
A
B
C
D
E
F
G
H
J
K
GPHE-50
71
68-5/8
52
21
9-1/8
12
22
8
15-3/4
27
Available in natural gas only.
Standard model certified for sea level to 5,300 ft. elevation. Order SMR K30 for elevations
to 10,100 ft.
Optional Condensate Neutralizer Kit available (Part Number 9007959005).
5
RESIDENTIAL GAS
VERTEX™ HIGH EFFICIENCY POWER
DIRECT VENT
ROUGH IN DIMENSIONS: 50 GALLON UNIT
Helical Internal Heat Exchanger
• Spiral heat exchanger keeps hot combustion gases in
the tank longer to lengthen the heat transfer cycle.
T&P
• Operates at 96% thermal efficiency, which saves
money on operating costs compared to a standard
80% efficient gas water heater.
ANODE
UPPER SIDE CONNECT
Power Direct Vent Design
• Combined vertical and horizontal runs terminating
through an outside wall. Vents using PVC, CPVC or
ABS pipe.
OUTLET
C
DIAMETER
• 2”pipe, vents up to 45 equivalent feet.
• 3”pipe, vents up to 128 equivalent feet.
LOWER SIDE CONNECT
• 96% efficient condensing design.
E
• Equipped with condensate drain tee.
• Allows Vertex to be installed as part of combination
space heating/water heating applications.
INLET
B
TOP VIEW
Condensing Design
Side-Mounted Hot and Cold Recirculating
Taps
F
A
*INSTALL IN ACCORDANCE
WITH LOCAL CODES.
D
DRAIN
FRONT VIEW
Figure 1: DIMENSIONS FOR 50 GALLON UNIT
ROUGH IN DIMENSIONS: 75 GALLON UNIT
Advanced Electronic Control
• Large LCD display.
• Precise temperature control.
F
• iCOMM™ compatible and can be monitored from
remote locations.
INLET
UPPER SIDE CONNECT
GDHE-75
• Call 1.888.WATER02 for more information.
Code Compliance
A
C
• Complies with SCAQMD Rule 1146.2 and other
air quality management districts with similar
requirements for Ultra-Low NOx emissions
requirements of 14 ng/J or 20 PPM.
• Meets the thermal efficiency and standby loss
requirements of the U. S. Department of Energy and
current edition of ASHRAE/IENSA 90.1.
Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
DIAMETER
E
DRAIN
ANODE
OUTLET
I
B
D
Figure 2: DIMENSIONS FOR 75 GALLON UNIT
Model
Number
GDHE-50
GDHE-75
Model
Number
GDHE-50
GDHE-75
6
LOWER SIDE
CONNECT
• Meets UBC, CEC and ICC National Codes.
GAS PIPING CONNECTIONS
T&P
• Advanced diagnostics.
Recovery @
Gallon
BTU Input
90°F Rise Gallon
Capacity
Per Hour
Per Hour
50
75
129
129
100,000
100,000
Vent
Size
Approx.
Shipping
Weight (lbs)
2 or 3
2 or 3
255
382
Dimensions in Inches
A
B
C
D
E
F
66-3/4
65-1/4
49-1/4
45-5/8
22
27-3/4
15-3/4
16
3
3-3/4
8
8
Available in Propane (LP) gas. Specify when ordering propane (LP) gas.
Models certified for sea level to 10,100 ft. elevation.
Optional Condensate Neutralizer Kit available (part number 9007959005).
7
RESIDENTIAL GAS
NON-CONDENSING
POWER VENT
ANODE
D
COLD
HOT
Versatile Power Vent Design
• All models feature an exclusive 3-position rotatable
blower outlet which adds flexibility.
• Combined horizontal and vertical vent runs up to
180 equivalent feet with 4” diameter venting (ABS,
PVC, CPVC and polypropylene).
• All models are equipped with a protected sensor
that detects the presence of flammable vapors and
automatically disables the burner to prevent ignition.
• Air intake snorkel elevates the inlet location of
combustion air to prevent flammable vapors from
entering the sealed combustion chamber.
Hot Surface Ignitor
Ø
• More robust and reliable than standing pilot, and
reduces energy consumption
Built-in Heat Traps on the Water Inlet and
Outlet Reduce the Amount of Heat Lost
Through Piping
2-inch, Thick, “Environmentally-Friendly”
Foam Insulation Reduces the Amount
of Heat Loss and Contributes to Overall
Energy Efficiency
User-Friendly
• State-of-the-art electronic gas control provides more
precise temperature control.
• LED control light displays operation status and
diagnostics information.
Enhanced-Flow Brass Drain Valve
Available in Natural Gas and Propane
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA)
as amended.
Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
8
Model
Number
GPVL-40
GPVT-40
GPVL-50
GPVT-50
GPVX-50L
†GPVX-75L
Model
Number
Series
200
200
200
200
200
210
40
40
50
50
50
75
0.70
0.70
0.70
0.70
0.70
N/A
44.7
55.9
44.7
55.9
69.3
80.4
40,000
50,000
40,000
50,000
62,000
76,000
73
90
90
96
110
N/A
174
176
198
192
212
277
Dimensions in Inches
A
59
GPVT-40
68-1/2
GPVL-50
60-1/8
GPVT-50
68-1/8
GPVX-50L
61-1/8
†GPVX-75L 70-5/8
GPVL-40
Recovery @ BTU
Approx.
Energy
First
Gallon
90°F Rise Input
Shipping
Factor
Hour
Capacity
Gallon Per Gallon
Weight
(EF)
Rating
Hour
Per Hour
(lbs)
B
C
D
E
F
G
H
49-5/8
59-1/4
50-3/4
58-3/4
52
61-1/4
22
20
24
22
24
26
29-1/8
27-1/8
31-1/8
29-1/8
31-1/8
33-1/8
11
11
11
11
11
11
13-1/4
13-1/4
13-1/4
13-1/4
13-1/4
13-1/4
42-1/2
53-1/8
43-3/4
51-3/4
44-1/2
53
15-1/4
15-1/4
15-1/4
15-1/4
15-1/4
15-1/4
Available in propane (LP) gas. Specify when ordering propane (LP) gas.
Side connections are standard on GPVX models.
Side connections available on GPVT models. Add “L” to the model number (example:
GPVT-40L).
All models are certified from sea level to 10,100 ft. elevation.
† GPVX-75L is not ENERGY STAR® Qualified.
9
RESIDENTIAL GAS
NON-CONDENSING
POWER DIRECT VENT
D
Power Direct Vent Design
• Combined horizontal and vertical vent runs up to
180 equivalent feet with 4” diameter venting (ABS,
PVC, CPVC and polypropylene).
• Two-pipe sealed combustion system uses outside air,
eliminating problems caused by insufficient indoor
ventilation.
Green Choice® Gas Burner
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
Hot Surface Ignitor
• More robust and reliable than standing pilot, and
reduces energy consumption.
C
Dynaclean™ Diffuser Dip Tube
A
B
User-Friendly
G
• State-of-the-art electronic gas control provides more
precise temperature control.
• LED control light displays operation status and
diagnostics information.
Enhanced-Flow Brass Drain Valve
F
H
E
CSA Certified and ASME Rated T&P Relief
Valve
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA)
as amended.
Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
10
Model
Number
Series
200
200
GPDX 50L
200
† GPDX 75L 210
GPDL 40
GPDT 50
Model
Number
Input
BTU/h
40
50
50
75
40,000
45,000
62,000**
76,000
0.71
0.70
0.71
N/A
71
93
115
N/A
45.2
50.3
72.6
82.4
174
192
200
277
Dimensions in Inches
A
58-1/4
GPDT 50
67-1/2
GPDX 50L
69
† GPDX 75L 70-5/8
GPDL 40
First Recovery @ Approx.
Energy Hour
90°F Rise Shipping
Factor Rating Gallon Per Weight
Gallon
Hour
(lb)
Gallon
Capacity
B
C
D
E
49-5/8
58-3/4
60-1/4
61-1/2
22
22
22
26
29-7/8
29-7/8
29-7/8
33-7/8
11
11
11
11
F
G
H
13-1/4 42-1/2 15-1/4
13-1/4 51-3/4 15-1/4
13-1/4 52-3/4 15-1/4
13-1/4
53
15-1/4
**Propane model has input of 58,000 BTU/hr.
Available in propane (LP) gas. Specify when ordering propane (LP) gas.
Side connections are standard on GPDX-50L and GPDX-75L.
Side connections available on GPDL-40 and GPDT-50. Add “L” to the model number
(example: GDPT-50L).
All models are certified from sea level to 10,100 ft. elevation.
† GPVX-75 is not ENERGY STAR® Qualified.
11
RESIDENTIAL GAS
PROMAX® DIRECT VENT
Direct Vent Design
• One-pipe, dual-channel closed system draws all
make-up air from outside the home, eliminating
problems caused by insufficient indoor ventilation
and is FVIR compliant.
• Horizontal air intake and venting on all models up
to 80 inches from outside wall with no electrical
power needed.
MINIMUM VENT
17”
MAXIMUM VENT
80”
21º
6” DIA. ON 40 & 50 GAL. MODELS
Intelligent Control Logic
Green Choice® Gas Burner
3/4” MALE NPT
OUTLET & INLET
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
Dynaclean™ Diffuser Dip Tube
EXTERIOR
WALL
SIDE TAP AND T&P
Coregard™ Andode Rod
A
FRONT
Push Button Piezo Ignitor
Heat Trap Nipples
Code Compliance
E
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure. Listed according to ANSI
Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model
Gallon
Number Capacity
GDV-40
GDV-50
GDVT-50
Model
Number
GDV-40
GDV-50
GDVT-50
First
Hour
Rating
Gallon
40
50
50
Recovery
Input
Energy
9OºF Rise Vent
BTU Per
Factor
Gallon Per Outlet
Hour
Hour
72
91
92
0.63
0.62
0.61
38,000
40,000
47,000
41
43
51
Co-Axial
Co-Axial
Co-Axial
Approx.
Shipping
Weight
(lbs)
178
200
215
Dimensions in Inches
A
B
C
64
73
74
49-3/4
59
60
22
22
22
D
E
F
13-1/4 15-1/4 42-1/2
13-1/4 15-1/4 51-3/4
13-1/4 15-1/4 52-3/4
*G
H
29
29
29
15-1/4
15-1/4
15-1/4
Dual-channel system has 3” vent pipe inside 6” air intake pipe, for the 40 and 50-gallon
models.
All models have 2” foam cavity.
Water connection is 3/4” male on all models.
40 and 50 gallon models are 8” on center.
*Allow 29-1/2” for front to back dimension for gas control and air intake pipe at the rear
of the heater.
All models are available in propane (LP) gas (series 301).
All models are certified from sea level to 7,700 ft. elevation.
All models available with side connections. Add “L” to the model number, example GDV-40L.
12
13
A
C
F
B
Pressurized Combustion System
Installation Friendly
ANODE ROD
G
RESIDENTIAL GAS
EFFEX® HIGH EFFICIENCY
ATMOSPHERIC VENT
GAS VALVE
H
ON/OFF SWITCH
HOT
CONNECTION
DRAIN VALVE
COLD CONNECTION
• Allows for easy replacement of standard atmospheric
vent heaters.
D
E
• Easily connects to existing B-vent.
TOP VIEW
Fan-Assisted, Category 1 Appliance
• Plugs into standard 110/120V outlet (10 foot power
FRONT VIEW
cord included).
1/2”
24V Electronic Controls
DRAFT HOOD
Electronic Ignition
T&P VALVE
LCD User Interface
• Easy-to-read, eye level display.
• Simple temperature settings and adjustments.
C
• Service diagnostics are in plain text.
Powered Anode Rod
Enhanced-Flow Brass Drain Valve
A
F
B
GAS VALVE
Dynaclean™ Diffuser Dip Tube
H
ON/OFF SWITCH
DRAIN VALVE
Green Choice® Gas Burner
• Patented eco-friendly gas burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less then 40 ng/J.
CON
D
Code Compliance
• Meets UBC, CEC and HUD National Codes.
FRONT VIEW
• Meets the thermal efficiency and standby loss
requirements of the U. S. Department of Energy and
current edition of ASHRAE/IENSA90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act, (EPCA),
as amended.
Model
Number
Gallon
Capacity
First
Hour
Rating
Gallons
Energy
Factor
(EF)
BTU Input
Gallon Per
Hour
GAHH-40
40
50
70
81
0.70
0.70
40,000
40,000
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure. Listed according to ANSI
Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
GAHH-50
Model
Number
GAHH-40
GAHH-50
14
Recovery
Approx.
@ 90°F
Shipping
Rise
Weight
Gallon Per
(lbs)
Hour
43
43
157
171
Dimensions in Inches
Foam
Thickness
2
2
A
B
C
D
E
F
G
H
Draft
Hood
61-3/4 58 20 13-1/4 8 51-1/2 23-1/4 25 3 or 4
60-5/8 57-1/8 22 13-1/4 8 50-1/2 25-1/4 27 3 or 4
Available in natural gas only.
Water connection is ¾” on all models.
All models are certified from sea level to 10,100 ft. elevation.
Requires 120 VAC power supply.
15
RESIDENTIAL GAS
HIGH EFFICIENCY NON-CONDENSING
FLUE DAMPER
ANODE ROD*
HOT
CONNECTION
Automatic Flue Damper
COLD
CONNECTION
• Increases efficiency as it automatically opens and
closes to reduce heat loss in the standby mode.
E
C
Electronic Gas Control
Diagnostics
Electronic Ignition
Dynaclean™ Diffuser Dip Tube
Green Choice® Gas Burner
T&P VALVE
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
1/2" GAS
CONNECTION
F
Coregard™ Anode Rod
A
B
Enhanced-Flow Brass Drain Valve
Blue Diamond® Glass Coating
D
CSA Certified And ASME RATED T&P
Relief Valve
* Location for optional top-mounted T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IENSA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act, (EPCA),
as amended.
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1 - CSA 4.1
standards governing storage tank-type water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model
Number
First
Recovery @
Energy
Gallon Hour
90°F Rise
Factor
Capacity Rating
Gallon Per
(EF)
Gallons
Hour
BTU Input
Gallon
Per Hour
Natural*
Approx.
Shipping
Weight
(lbs)
Tall Models
GCF-40
GCF-50
40
50
67
81
0.67
0.67
42
42
40,000
40,000
152
167
40
50
67
88
0.67
0.67
42
42
40,000
40,000
149
175
Short Models
GCFL-40
*GCFL-50
Dimensions in Inches
Model
Number
Foam
Thickness
A
B
C
D
E
F
Draft
Hood
Outlet
2
2
64-1/4
63-1/2
58-1/4
57-1/4
20
22
13
13
8
8
51-3/4
50-1/4
3 or 4
3 or 4
2
2
54
55-3/4
47-3/4
49-1/2
22
13
8
24 13-1/4 8
41
42-1/2
3 or 4
3 or 4
Tall Models
GCF-40
GCF-50
Short Models
GCFL-40
*GCFL-50
16
Requires 120 VAC power supply.
Water connection is ¾” on all models.
Specify when ordering Top T&P.
All models are certified from sea level to 10,100 ft. elevation.
*GCFL-50 available in natural gas only. All other models available in propane (LP) gas.
17
RESIDENTIAL GAS
PROMAX®
ATMOSPHERIC VENT
Intelligent Control Logic*
• *Not available on 60,000 BTU input models (GCRX50 and GCRX-55).
Dynaclean™ Diffuser Dip Tube
Coregard Anode Rod
™
Push-Button Piezo Ignitor
Enhanced-Flow Brass Drain Valve
Heat Trap Nipple
Blue Diamond® Glass Coating
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Design-Certified By CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type gas water
heaters.
Model
Number
First
BTU
BTU
Recovery Approx.
Gallon Hour Energy Input
Input 90°F Rise Shipping
Capacity Rating Factor Natural Propane Gallon Per Weight
Gallon
Gas
Gas
Hour
(lbs)
Tall Models
†GCB-30
GCR-30
‡GCRH-40
†GCB-40
GCR-40*
GCG-50*
GCR-50*
GCRT-50*
†GCRX-50*
Short Models
†GCBL-30
GCRL-30
†GCBL-40
GCRL-40
GCRL-50
30
30
40
40
40
50
50
50
50
64
67
67
70
70
88
88
92
98
0.63
0.63
0.62
0.62
0.62
0.60
0.62
0.60
0.60
35,500
35,500
35,500
40,000
40,000
40,000
40,000
50,000
60,000
32,000
32,000
N/A
36,000
36,000
37,000
37,000
45,000
54,000
37
37
38
42
42
41
43
54
65
123
132
138
130
138
148
165
165
190
30
30
40
40
50
56
62
67
68
93
0.63
0.63
0.62
0.62
0.60
35,500
35,500
40,000
40,000
40,000
32,000
32,000
36,000
36,000
40,000
37
37
41
41
43
110
118
134
135
177
Water connection is ¾” on all models.
For 10-year tank and 6-year parts warranty, change “G” to “X” in model number (example:
XCR-30).
All models approved for installation from sea level to 10,100 ft. elevation.
† Models ship with supplied insulation blanket
Specify when ordering propane (LP) gas.
‡ LP models not available on GCRH-40
*For optional side-mounted recirculating taps, add "L" to the suffix in the model number.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Line drawings and dimensions on the following page.
18
19
RESIDENTIAL GAS
PROMAX®
ATMOSPHERIC VENT (CONTINUED)
ANODE ROD
(OPTIONAL T&P
ANODE
ROD
LOCATION)
(OPTIONAL T&P
LOCATION)
HOT
CONNECTION
HOT
(ANODE OUTLET
CONNECTION
ON T&P
MODELS)
(ANODE OUTLET
ON T&P MODELS)
E
C
E
C
COLD
CONNECTION
COLD
CONNECTION
T&P VALVE
T&P VALVE
1/2" GAS
CONNECTION
1/2" GAS
CONNECTION
F
F
H
H
B
B
A
A
D
G
D
G
Maximum Hydrostatic Working Pressure: 150 PSI
Maximum Hydrostatic Working Pressure: 150 PSI
Model
Number
Tall Models
†GCB-30
GCR-30
‡GCRH-40
†GCB-40
GCR-40*
GCG-50*
GCR-50*
GCRT-50*
†GCRX-50*
Short Models
†GCBL-30
GCRL-30
†GCBL-40
GCRL-40
GCRL-50
Model
Number
Tall Models
†GCB-30
GCR-30
‡GCRH-40
†GCB-40
GCR-40*
GCG-50*
GCR-50*
GCRT-50*
†GCRX-50*
Short Models
†GCBL-30
GCRL-30
†GCBL-40
GCRL-40
GCRL-50
Dimensions in Inches
C
A
B
61-1/2
61-1/2
61-3/4
61-3/4
61-3/4
60-3/4
60-3/4
60-3/4
65-1/2
58
58
58-1/4
58-1/4
58-1/4
57-1/4
57-1/4
57-1/4
61
50
50
51-1/2
51-1/2
53-1/4
46-1/2
46-1/2
48
48
49-3/4
F
D
E
16
18
20
18
20
21
22
22
22
12-1/4
12-1/4
12-1/4
12-1/4
12-1/4
12-1/4
12-1/4
12-1/4
13-1/2
8
8
8
8
8
8
8
8
8
18
20
20
22
24
12
12
12
12
12
8
8
8
8
8
Dimensions in Inches
*G
*H
Draft Hood
51-3/4
51-3/4
52
52
52
50 1/2
50-1/2
50-1/2
54-1/4
N/A
N/A
N/A
N/A
14-1/4
14-1/4
14-1/4
14-1/4
14-1/4
N/A
N/A
N/A
N/A
51-3/4
50-1/2
50-1/2
50-1/2
50-1/4
3 or 4
3 or 4
3 or 4
3 or 4
3 or 4
3 or 4
3 or 4
4
4
40
40
41-1/4
41-1/4
41-3/8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3 or 4
3 or 4
3 or 4
3 or 4
3 or 4
Water connection is ¾” on all models.
For 10-year tank and 6-year parts warranty, change “G” to “X” in model number (example:
XCR-30).
All models approved for installation from sea level to 10,100 ft. elevation.
† Models ship with supplied insulation blanket
Specify when ordering propane (LP) gas.
‡ LP models not available on GCRH-40
*For optional side-mounted recirculating taps, add "L" to the suffix in the model number.
20
21
RESIDENTIAL GAS
HOT WATER
INLET
PROMAX HIGH RECOVERY
ATMOSPHERIC VENT 75 & 100 GALLON
®
TOP VIEW
COLD WATER
INLET
E
T&P
TEMPERATURE
AND PRESSURE
RELIEF VALVE
Highest Recoveries
DRAIN
• Capacity/input combinations
up to 98
VALVE
gallons/75,100 BTU’s to produce recoveries up toC81
gallons per hour.
COLD
HOT
Fully Automatic ControlsF with Safety
Shutoff
B
H
A
HOT WATER
INLET
• Requires no electrical connections.
• Fixed automatic gas shutoff device for added safety.
GAS INLET
Green Choice® Gas Burner
D design reduces NOx
• Patented eco-friendly burner
emissions up to 33% and complies with Low-NOx
emission requirements of 40 ng/J.
T&P
G
DRAIN
VALVE
Dynaclean™ Diffuser Dip Tube
Coregard Anode Rod
™
COLD WATER
INLET
DRAIN VALVE
C
FRONT VIEW
F
Push-Button Piezo Ignitor
B
H
A
Blue Diamond® Glass Coating
Enhanced-Flow Brass Drain Valve
D
Code Compliance
G
• Meets UBC, CEC and ICC National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
FRONT VIEW
CSA Certified and ASME Rated T&P Relief
Valve
Model Number
Maximum Hydrostatic Working Pressure
150 psi
FCG-100
FCG-75
Gallon
Capacity
BTU Input
Natural Gas
Recovery @
90°F Rise Gallon
Per Hour
74
98
75,100
75,100
81
81
Design-Certified By CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type gas water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model Number
FCG-75
FCG-100
Model Number
FCG-75
FCG-100
22
Approx.
Shipping
Weight (lbs)
275
350
Dimensions in Inches
A
B
C
D
E
61
68-1/2
58-1/2
66-1/2
26-1/2
27-3/4
15-3/16
15-3/16
16
16
Dimensions in Inches
F
G
H
Draft Hood
50-1/4
57-3/8
15-1/2
N/A
50-1/4
N/A
4
4
Water connections are 1” male NPT on FCG-75 and 1-1/4” on FCG-100.
For 10-year tank and 6-year parts limited warranty, change “F” to “P” in model number
(example: PCG-75).
For optional side-mounted recirculating taps, add “L” to the suffix of the model number
(example: FCG-75L).
Specify when ordering propane (LP) gas.
All models are certified from sea level to 7,700 ft. elevation.
23
RESIDENTIAL GAS
ENERGY SAVER
ATMOSPHERIC VENT
Complies with HUD Standards for
Manufactured Housing Installation
ANODE ROD
HOT WATER OUTLET
CONNECTION 3/4˝
NIPPLE SUPPLIED
Gas Control Convertible for Natural and
Propane Gas
• For flexibility to meet the varying needs of
manufactured housing installations.
Side-Mounted 3/4” Cold Water Inlets
T&P VALVE
• For flexibility to meet the varying needs of
manufactured housing installations.
• Top-mounted 3/4” hot water outlet.
Green Choice® Gas Burner
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
A
Coregard™ Anode Rod
B
C
F
COLD WATER INLET
CONNECTION,
3/4˝ NIPPLE SUPPLIED
Blue Diamond® Glass Coating
Enhanced-Flow Brass Drain Valve
Code Compliance
• Meets UBC, CEC and HUD National Codes.
E
D
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
GAS CONNECTOR
1/2˝ FEMALE
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type gas water
heaters.
CSA Certified and ASME Rated T&P Relief
Valve
Model
Number
FMHR-30
FMHR-40
Recovery
First
BTU Input BTU Input
Approx.
@ 90°F
Gallon Hour Energy Per Hour Per Hour
Shipping
Rise
Capacity Rating Factor Natural
Propane
Weight
Gallon
Gallon
Gas
Gas
(lbs)
Per Hour
30
40
55
62
6-Year Limited Tank and 2-Year Limited
Tank Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
0.63
0.62
35,500
35,500
32,000
32,000
36
36
129
153
Dimensions in Inches
Model
Number
FMHR-30
FMHR-40
Insulation
2
2
A
B
C
D
E
F
61-1/2
58
18 13 14-1/4
52
61-3/4 58-1/4 20 13 14-1/4 51-3/4
Draft
Hood
Outlet
3 or 4
3 or 4
All models ship from factory for use with natural gas. A complete propane (LP) burner is
supplied for converting to propane gas.
No option available for top T&P.
Certified from sea level to 10,100 ft. elevation.
24
25
RESIDENTIAL GAS
ENERGY SAVER DIRECT VENT
Complies With HUD Standards For
Manufactured Housing Installation
ANODE ROD
HOT WATER OUTLET
CONNECTION 3/4˝
NIPPLE SUPPLIED
Gas Control Convertible for Natural and
Propane Gas
• For flexibility to meet the varying needs of
manufactured housing installations.
Direct Vent Models Package with Bottom
Intake Air Vent
T&P VALVE
• To draw all combustion make-up air from outside
the structure.
Optional Ducted Air Inlet Kit for Direct
Vent Models
• For use when water heater is installed over a
basement.
A
• Provision for horizontal air inlet ducting.
Side-Mounted 3/4” Cold Water Inlets
B
C
F
COLD WATER INLET
CONNECTION,
3/4˝ NIPPLE SUPPLIED
Green Choice® Gas Burner
• Patented eco-friendly burner design reduces NOx
emissions by up to 33% and complies with Low-NOx
emission requirements of less than 40 ng/J.
E
Dynaclean™ Diffuser Dip Tube
D
Coregard™ Anode Rod
Enhanced-Flow Brass Drain Valve
GAS CONNECTOR
1/2˝ FEMALE
Blue Diamond Glass Coating
®
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type gas water
heaters.
CSA Certified and ASME Rated T&P Relief
Valve
6-Year Limited Tank and 2-Year Limited
Parts Warranty
26
• For complete information, consult written warranty
or go to hotwater.com.
Btu
Recovery
First
Btu
Approx.
Input
@ 90°F
Model Gallon Hour Energy
Input
Vent Shipping
Per Hour
Rise
Number Capacity Rating Factor
Per Hour
Outlet Weight
Natural
Gallon
Gallon
Propane
(lbs)
Gas
Per Hour
FMDV-30
FMDV-40
FMDV-50
Model
Number
FMDV-30
FMDV-40
FMDV-50
30
40
50
49
61
77
0.63 30,000 29,000
0.62 32,000 29,000
0.60 40,000 37,000
31
33
39
3
3
3
129
153
168
Dimensions in Inches
Insulation
2
2
2
A
B
61
58
61-3/4 58-3/4
60
57
C
D
E
F
18
20
22
13
13
13
14-1/4
14-1/4
14-1/4
52-1/2
52-1/4
50
All models ship from the factory for use with natural gas, a complete propane burner is
supplied for converting to propane gas.
No option available for top T&P.
Water connections-3/4” on all models.
All models are certified for installation from sea level to 5,400 ft. elevation.
27
RESIDENTIAL GAS
PROMAX® ULTRA-LOW NOx
ANODE ROD
(OPTIONAL T&P
LOCATION)
HOT
CONNECTION
(ANODE OUTLETON
TOP T&P MODELS)
Intelligent Control Logic
COLD
CONNECTION
High Energy Factors
E
• Eco-Friendly non-CFC foam insulation, external heat
traps and specially designed combustion chamber
combine to produce a high Energy Factor for
maximum savings on operating costs.
Green Choice® Gas Burner
• Enhanced Ultra-Low NOx burner complies
with SCAQMD Rule 1121 and other air quality
management districts with similar requirements for
NOx emissions of less than 10 ng/J.
T&P VALVE
C
F
Dynaclean Diffuser Dip Tube
1/2" GAS
CONNECTION
Coregard™ Anode Rod
Push-Button Piezo Ignitor
B
H
™
A
G
D
Heat Trap Nipples
Maximum Hydrostatic Working Pressure: 150 PSI
Blue Diamond® Glass Coating
Enhanced-Flow Brass Drain Valve
Code Compliance
• Meets UBC, CEC and HUD National Codes.
Model
Gallon
Number Capacity
Tall Models
GUC-30
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
GUC-40
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
GUC-50
CSA Certified by CSA International
Design-Certified by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure. Listed according to ANSI
Z21.10.1-CSA 4.1 standards governing storage tanktype gas water heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Recovery @
First Hour
BTU Input
Approx.
Energy
90°F Rise
Rating
Natural
Shipping
Factor
Gallon Per
Gallon
Gas
Weight (lbs)
Hour
GUR-40
GUR-50
GURT-50L*
30
40
40
50
50
50
55
71
71
91
91
98
0.63
0.62
0.63
0.60
0.62
0.60
33,000
40,000
40,000
40,000
40,000
50,000
34
41
41
42
42
51
126
125
125
148
148
177
40
69
0.62
40,000
41
138
Short Models
GURL-40
Dimensions in Inches
Model
Number
A
B
C
58
D
E
F
G*
H*
Draft
Hood
Tall Models
GUC-30
61-3/4
16
12
8
51-3/4
N/A
N/A
3 or 4
GUC-40
62
58-1/4 18
12
8
52
N/A
N/A
3 or 4
GUR-40
62
58-1/4 20
12
8
52
N/A
N/A
3 or 4
GUC-50
60-3/4 57-1/4 20
12
8
50-1/2
N/A
N/A
3 or 4
GUR-50
60-3/4 57-1/4 22
GURT-50L*
61
57-1/2 22
12
8
50-1/2
N/A
N/A
3 or 4
12-1/4
8
50-1/2
12-1/4
50-1/2
4
12
8
41-1/4
N/A
N/A
3 or 4
Short Models
GURL-40
51-1/2 47-3/4 22
All models may be ordered from the factory with top T&P.
Side loop connections are standard on model (GURT-50L).
Most models approved for installation from sea level to 7,700 ft. elevation (except on
GURT-50L which isapproved to 5,400 ft.).
28
29
RESIDENTIAL GAS
BLOWER
HIGH EFFICIENCY NONCONDENSING ULTRA-LOW NOx
POWER VENT
Power Venting Made Simple
• Thru-the-wall or thru-the-roof power venting using
either 2” or 3” PVC. ABS or CPVC vent pipe.
Intelli-Vent™ Gas Control
• Advanced electronics for more precise control of
water temperature and easy to understand system
diagnostics.
40-GAL. = 25"
50-GAL. = 27"
EXHAUST
OUTLET
Combination Thermostat/ECO
• Utilizes an intermittent ignition gas valve (no
standing pilot) with thermistor temperature sensor
and built-in high temperature cut off.
E
Quiet and Efficient
Blower
BLOWER
• Factory-installed 6-foot power cord with standard
3-prong male connector provided. Electrical
requirements; 110/120 VAC power source less than
5 amp draw.
Dynaclean™ Diffuser Dip Tube
• Reduces lime and sediment buildup and maximizes
hot water output. Made from long-lasting PEX crosslinked polymer.
Coregard™ Anode Rod
Green Choice® Gas Burner
• Complies with SCAQMD Rule 1121 and other
air quality management districts with similar
requirements for NOx emissions of less than 10 ng/J.
Enhanced-Flow Brass Drain Valve
Code Compliance
E
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U. S. Department of Energy and
current edition of ASHRAE/IENSA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act, (EPCA),
as amended.
Design-Certified by CSA-International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10.1-CSA 4.1
standards governing storage tank-type gas water
heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com
Model
Number
Gallon
Capacity
First Hour
Rating
Gallon Per
Hour
GPNH-40
40
50
69
81
GPNH-50
Model
Number
GPNH-40
GPNH-50
Recovery
BTU
Approx.
@ 90°F
Energy
Input
Shipping
Rise
Factor
Gallon
Weight
Gallon Per
Per Hour
(lbs)
Hour
0.68
0.68
42.6
42.6
42,000
42,000
Dimensions in Inches
170
207
A
B
C
D
E
Draft
Hood
20
22
66-7/8
66-5/8
58-5/8
57-7/16
51-1/2
51
12-1/4
12-1/4
2 or 3
2 or 3
No option available for top T&P valve.
30
31
RESIDENTIAL GAS
PROMAX® ULTRA-LOW NOx
DIRECT VENT
Flammable Vapor Resistant/Direct Vent
Sealed Combustion System
Durable, Ultra-Low NOx Burner
Construction
TOP VIEW
5˝
HOT OUTLET
17˝/22˝ MIN.
80˝ MAX. HORIZONTAL VENT
E
COLD INLET
Non-CFC Foam Insulation
• The tank is surrounded by a thick coat of non-CFC
polyurethane foam to trap heat inside the tank,
saving energy.
MAX. HEIGHT IS
68˝ ABOVE
TOP OF HEATER
THRU-THE-WALL
INSTALLATION
¾” Top Water Connections and Side
Space Heating Connections
½” Gas Connection
Coregard™ Anode Rod
Blue Diamond® Glass Coating
Enhanced-Flow Brass Drain Valve
Green Choice® Gas Burner
• Complies with SCAQMD Rule 1121 and other
air quality management districts with similar
requirements for NOx emissions of less than 10
ng/J.
OUTLET
C
T&P
VALVE
T&P
VALVE
A
B
F H
GAS
VALVE
D
INLET
G
SIDE VIEW
FRONT VIEW
Code Compliance
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act
(EPCA), as amended.
CSA Certified And ASME Rated T&P
Valve.
Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to ANSI Z21.10-1- CSA 4.1
standards governing storage tank-type gas water
heaters.
CSA Certified and ASME Rated T&P
Relief Valve
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
32
Gallon
Model Number
Capacity
GDNL-40L-100
GDNT-50L-100
Recovery
@ 90°F
Energy
Rise
Factor
Gallon Per
Hour
First
Hour
Rating
Gallon
40
50
59
81
0.62
0.62
39
41
BTU
Input
Per
Hour
Approx.
Shipping
Weight
(lbs)
36,000
38,000
179
193
Model Number
Concentric
Vent
Connection
A
B
C
D
GDNL-40L-100
3 or 5
65-1/4
50-1/2
22
13-1/2
GDNT-50L-100
3 or 5
73-1/2
58-1/2
22
13-1/2
Model Number
GDNL-40L-100
GDNT-50L-100
Dimensions in Inches
Dimensions in Inches
E
F
G
H
30
30
43-7/8
52-1/4
15
15
45
53
No option available for top T&P valve.
All models have ¾” top water connections and comes standard with side loop fittings.
All models certified from sea level to 7,700 ft. elevation.
33
K
HOT WATER
RESIDENTIAL GAS
OUTLET
®
PROMAX ULTRA-LOW NOx
HIGH RECOVERY
J
TOP VIEW
K
COLD WATER
INLET
F
H
TEMPERATURE
AND PRESSURE
RELIEF VALVE
Fully Automatic Controls with Safety
DRAIN
Shutoff
VALVE
Heavy Gauge Steel Jacket
D
Blue Diamond® Glass Coating
Foam Insulation
C
COLD
HOT
G
B
A
DRAIN VALVE
Ultra-Low NOx Emissions
• Complies with SCAQMD Rule 1146.2 and other
Air Quality Management Districts with similar
E
requirements of 14 ng/J or 20 ppm.
Easy-To-Install
K
HOT WATER
OUTLET
L
GAS INLET
M
K
COLD WATER
INLET
F
J
• Completely factory-assembled. Only gas, water and
vent connections need to be made. All connections
are located in front and top of heaters for ease-ofinstallation and service.
DRAIN
VALVE
Coregard Anode Rod
™
D
• Our anode rods have a stainless steel core that
extends the life of the anode rod allowing superior
tank protection far longer than standard anode rods.
B
Maximum Working Pressure
A
• 150 psi.
Maximum Gas Inlet Pressure
• 14” W.C.
E
Code Compliance
M
• The Ultra-Low NOx atmospheric vent residential
gas water heater meets the thermal efficiency and
standby loss requirements of the U. S. Department of
Energy and Current Edition ASHRAE/IESNA 90.1.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model
Number
Gallon
Recovery @ 90°F
Capacity Rise Gallon Per Hour
BTU Input
Per Hour
Approx.
Shipping Weight
75,100
75,100
285 lbs
350 lbs
GCN-100
74
98
Model
A
B
C
D
E
F
GCN-100
62-1/16
70-1/2
58
66-1/2
29-1/2
30-15/16
25-1/4
27-3/4
15-7/8
15-3/16
4
4
Model
G
H
J
K
L
M
15-1/4
15-3/4
16
16
2
1-1/4
1
1-1/4
1/2
1/2
12-1/2
11-15/16
† GCN-75
81
82
Dimensions in Inches
GCN-75
Dimensions in Inches
GCN-75
GCN-100
34
*Recover rating based on 81% thermal efficiency.
**Recover rating based on 80% thermal efficiency.
†The GCN-75 comes standard with side loop fittings for use with hydronic heating
applications.
35
RESIDENTIAL GAS
TANKLESS CONDENSING
HIGH EFFICIENCY
INDOORMODEL
MODEL
INDOOR
Front view
Side view
13-7/8" (352mm)
10" (254mm)
6-1/4" (158.5mm)
4" (102mm)
4" (102mm)
10-13/16" (274.6mm)
10-5/16" (262.2mm)
6" (152.1mm)
2-9/16" (64.8mm)
2-3/4" (70.2mm)
ENERGY STAR® Qualified
58.4
24" (609.4mm)
Ultra-Low NOx Emissions
• Complies with SCAQMD 1146.2 NOx emission
requirements of 14 ng/J or 20 PPM.
22-7/8 (580mm)
Condensing Technology Provides 0.93
Energy Factor (EF)
Copper Primary Heat Exchanger
• 25x better heat transfer than stainless steel thus
stabilizing outgoing water temperature quicker and
reducing pressure drop across the heat exchanger.
Hot 4-3/4" (121.1mm)
Condensate drain port
5-1/16" (129.1mm)
1" (25.5mm)
Condensate drain port 3-1/4" (82.1mm)
Gas 4-1/8" (105.4mm)
Hot 6-1/2" (164.6mm)
Cold 7" (178.5mm)
120VAC 7-3/4" (196.5mm)
Cold 1/2" (13.3mm)
120VAC 3-1/16" (77mm)
5-3/8" (137mm)
7-1/16" (180mm)
Gas 4/1/2" (113.7mm)
Secondary Heat Exchanger
MODEL
OUTDOOR
MODELTop view
• Marine-Grade 316L stainless steel to protect against
corrosion.
Bo om OUTDOOR
view
13-5/16" (338.1mm)
22-7/8 (580mm)
Factory-Installed Power Cord Included for
Indoor Models
6" (152.1mm)
COLD 7-1/16" (179.2mm)
1/2" (13.3mm)
4-3/4" (121.1mm)
3-1/16" (77mm)
5-1/16" (129.1mm) 3"4-1/2"
(113.7mm)
(75.5mm)
8" (203mm)
Side view
120VAC 7-3/4" (197.2mm)
• Include a wall mount temperature remote
controller and advanced diagnostics to simplify
troubleshooting.
13-7/8" (352mm)
10" (254mm)
7-1/16" (180mm)
5-3/8" (137mm)
2-9/16" (65.8mm)
1-11/16" (42.5mm)
GAS 4-3/16" (106.1mm)
Outdoor Models
Condensate drain port
HOT 6-1/2" (165.3mm)
• Include a built-in temperature controller and
advanced diagnostics to simplify troubleshooting.
Front view
3-1/4" (82.8mm)
Indoor Models
10-3/4" (272.4mm)
10-5/16" (262.2mm)
2-5/16" (58.4mm)
6-1/4" (158.5mm)
Electronic Ignition - No Pilot Light
Safety Features:
• Air-Fuel Ratio (AFR) Sensor.
Condensate drain port
5-1/16" (129.1mm)
CSA 4.3
• 15-year limited warranty on heat exchanger in
residential applications.
• 10-year limited warranty on heat exchanger in
commercial applications.
• 5-year limited warranty on all parts.
Model
Number*
Condensate drain port
3-1/4" (82.8mm)
ANSI Z21.10.3
Hot 6-1/2" (164.6mm)
Top view
Bo om view
HOT 6-1/2" (165.3mm)
Warranty
Gas 4/1/2" (113.7mm)
Cold 7" (178.5mm)
Internal Freeze Protection System
Power Vent or Power Direct Vent Design
1" (25.5mm)
Condensate drain port 3-1/4" (82.1mm)
120VAC 3-13/16" (96.1mm)
Gas 4-1/8" (105.4mm)
Cold 1/2" (13.3mm)
120VAC 1-7/16" (36.8mm)
Type
13-5/16" (338.1mm)
Maximum Inlet Gas Pressure Energy
Hot/Cold
Gas
Input
Minimum Maximum Factor
Connections Connection
(BTU/H)
(EF)
in. W.C. in. W.C.
Indoor Models
ATI-140H-N
Natural
120,000
5.0
10.5
1/2" (13.3mm)
4-3/4" (121.1mm)
1-7/16"Sizing
(36.8mm)Chart
5-1/16" (129.1mm)
4-1/2" (113.7mm)
Model
Number*
Type
Cold
Climate**
Indoor Models
ATI-140H-N
Natural
1.5
0.93
3/4” NPT
1/2” NPT
Clearance (Inches)
(Number of Showers)
GAS
4-3/16" (106.1mm)
• Overheat Cut-Off Fuse.
5-3/8" (137mm)
7-1/16" (180mm)
COLD
7-1/16" (179.2mm)
• Exhaust & Water Temperature Safety Control.
Hot 4-3/4" (121.1mm)
Warm
Climate***
Top
Bottom
2
12
12
Side Front
2
4
Back
0.5
*For propane models, change “N” to “P” in the model number (example: ATI-140H-P)
For outdoor models change “I” to “O” in the model number (example: ATO-140H-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
36
37
INDOOR
MODEL
INDOOR MODEL
4" (102 mm)
Female
ENERGY STAR® Qualified
6-1/4" (159mm)
22-1/2" (570 mm)
24-7/8" (631 mm)
Ultra-Low NOx Emissions
5-3/4" (147 mm)
23-5/8" (600 mm)
Condensing Technology Provides 0.95
Energy Factor
11-1/4" (285 mm)
4" (101 mm)
4" (102 mm)
Female
10-3/4" (272mm)
• Complies with SCAQMD 1146.2 NOx emission
requirements of 14 ng/J or 20 PPM.
HOT 4-3/4" (120 mm)
Drain port
6-3/4" (170 mm)
Heat Exchanger
• Include integrated temperature controls and
advanced diagnostics to simplify troubleshooting.
• Include factory-installed power cords
11" (281
mm)(448 mm)
17-5/8"
22-1/2" (570 mm)
5-3/4" (147 mm)
Indoor Models
11-1/4" (285 mm)
4-1/2" (114 mm)
GAS 5-1/8" (131 mm)
3-5/8" (92 mm)
COLD 6-3/4"
(172 mm)
1-1/2"
(37 mm)
• Secondary heat exchanger is made of marinegrade 316L stainless steel to protect against
corrosion.
OUTDOOR
MODEL
OUTDOOR MODEL
Condens ate drain port
7-1/2" (189 mm)
HOT 4-3/4" (120 mm)
GAS 5-7/8" (147 mm)
17-3/4" (450 mm)
120 VAC 3" (77 mm)
7" (180 mm)
24-7/8" (631 mm)
HOT 5-1/2" (140 mm)
23-5/8" (600 mm)
120 VAC 6-7/8" (174 mm)
• Primary heat exchanger of the ATI/ATO-540 is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperature quicker and reducing
pressure drop across the heat exchanger.
1/2 (13 mm)
GAS 5-1/8" (131 mm)
HOT 5-1/2" (140 mm)
Drain port 6" (152 mm)
COLD 6-3/4" (172 mm)
120 VAC 6-7/8" (174 mm)
Condens ate drain port
7-7/8" (199 mm)
COLD 5/8" (17 mm)
120 VAC 3" (77 mm)
GAS 5-3/4" (147 mm)
Condens ate drain port
7-1/2" (189 mm)
Condensate drain port
7-7/8" (199 mm)
Maximum Flow Rates up to 10.0 GPM
COLD 5/8" (17 mm)
6-1/4" (159 mm)
Outdoor Models
• Include a wall mount temperature remote
controller and advanced diagnostics to simplify
troubleshooting.
10-3/4" (272 mm)
HOT 4-3/4" (120 mm)
120 VAC 6-1/4" (159 mm)
Drain port
6-3/4" (170 mm)
1/2" (13 mm)
120 VAC 3" (77 mm)
GAS (131 mm)
HOT (140 mm)
Drain port 6" (152 mm)
COLD 5/8" (17 mm)
GAS 5-3/4" (147 mm)
Condens ate drain port
7-1/2" (189 mm)
Common Vent Indoor Models up to 8
Units
COLD 6-3/4" (172 mm)
Condens ate drain port
7-7/8" (199 mm)
540H
ANSI Z21.10.3
CSA 4.3
• Exhaust & Water Temperature Safety Control.
• Overheat Cut-off Fuse.
Internal Freeze Protection System
Power Vent or Power Direct Vent Design
Warranty
• 15-year limited warranty on heat exchanger in
residential applications.
• 10-year limited warranty on heat exchanger in
commercial applications.
38
• 5-year limited warranty on all parts.
Natural
160,000
Natural
180,000
ATI-540H-N
Natural
199,000
120 VAC
6-1/4" (159 mm)
Model
Number*
COLD 6-3/4" (172 mm)
ATI-240H-N
ATI-340H-N
5.0
5.0
5.0
Condensate drain port
7-7/8" (199 mm)
• Air-Fuel Ration (AFR) Sensor.
17-5/8" (448 mm)
GAS 5-1/8" (131 mm)
• Multi-link up to 20 heaters.
Safety Features
Inlet Gas Pressure Energy
Maximum
Hot/Cold
Gas
Condens ate drain port
7-1/2" (189 mm)Minimum Maximum Factor
BTU/H
Connections Connection
(EF)
in. W.C. in. W.C.
Indoor Models
HOT 5-1/2" (140 mm)
• Easy-link up to 4 heaters.
Model
HOT 4-3/4" (120 mm)
Type
Number*
120 VAC 3" (77 mm)
• Can be used in residential and commercial
applications
Intake
2-5/8" (68 mm)
17-3/4" (450 mm)
7" (180 mm)
Exhaust
2-5/8" (65 mm)
RESIDENTIAL GAS
TANKLESS CONDENSING
HIGH EFFICIENCY
10.5
0.95
3/4” NPT
3/4” NPT
10.5
0.95
3/4” NPT
3/4” NPT
10.5
0.95
3/4” NPT
3/4” NPT
COLD 5/8" (17 mm)
Sizing Chart (Number of
Type
Clearance (Inches)
Showers)
Cold
Climate**
Warm
Climate***
Top
Bottom Side Front Back
Indoor Models
ATI-240H-N
ATI-340H-N
ATI-540H-N
Natural
Natural
Natural
2
3
12
12
2
4
2.5
3.5
12
12
2
4
0.5
3
4
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example:ATI-240H-P)
For outdoor models change “I” to “O” in the model number (example: ATO-240-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
0.5
39
INDOOR MODEL
13-3/4" (350mm)
10" (254mm)
4" (101 mm)
13-3/4" (350mm)
10" (254mm)
1-3/4"
(45mm)
1-3/4" (45mm)
4-3/8" (113mm)
1-3/4" (45mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
1-5/8" (43mm)
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
• *Easy-Link up to 4 units
19-3/8" (493mm)
OUTDOOR MODEL
13-3/4" (350mm)
13-3/4" (350mm)
10" (254mm)10" (254mm)
7-7/8" (203mm)
7-7/8" (203mm)
1-3/4" (45mm)
1-3/4" (45mm)
1-3/4" (45mm)
1-3/4" (45mm)
5" (128mm) 5" (128mm)
Low NOx Emissions
ATI-510 & ATO-510 Can Be Used In Both
Residential and Commercial Applications
1" (26mm)
COLD 2-7/8" (71mm)
1" (26mm)
120VAC 3-7/8" (99mm)
COLD 2-7/8" (71mm)
GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm)
HOT 6-1/2" (164mm)
GAS 5-1/4" (135mm)
9-1/2" (241mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
4-3/8" (113mm)
4-3/8" (113mm)
19-3/8" (493mm)
Factory-Installed Power Cord Included For
Indoor Models
HOT 5-1/4" (133mm)
1-7/8" (47mm) 120V 1-3/8" (36mm)
COLD 3-1/4" (84mm) GAS 4-7/8" (124mm)
19-3/8" (493mm)
• Includes a wall mount temperature remote
controller and advanced diagnostics to simplify
troubleshooting
19-3/8" (493mm)
1-7/8" (47mm)
COLD 3-1/4" (84mm)
Indoor/Outdoor Models
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
1-3/8" (36mm)
21-3/8" (544mm)
• Primary heat exchanger of the ATI/ATO-510 is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperatures quicker and reducing
pressure drop across the heat exchanger
1-5/8" (43mm)
1-3/8" (36mm)
Maximum Flow Rates up to 10.0 GPM
Copper Primary Heat Exchanger
4-3/8" (113mm)
4" (101 mm)
1-3/4" (45mm)
1-5/8" (43mm)
RESIDENTIAL GAS
TANKLESS NON-CONDENSING
Safety Features
• Air-Fuel Ratio (AFR) Sensor
1" (26mm) 1" (26mm)
2-7/8" (71mm)
COLD 2-7/8"COLD
(71mm)
120VAC
3-7/8" (99mm)
120VAC 3-7/8"
(99mm)
GAS
5-1/4" (135mm)
GAS 5-1/4" (135mm)
120V
1-3/8"
(36mm)
120V 1-3/8" (36mm)
HOT 6-1/2" (164mm)
HOT 6-1/2" (164mm)
GAS 4-7/8" (124mm)
9-1/2" (241mm)
GAS 4-7/8" (124mm)
9-1/2" (241mm)
• Exhaust & Water Temperature Safety Control
• Overheat cut-off fuse
1-7/8" (47mm)
1-7/8" (47mm)
3-1/4" (84mm)
COLD 3-1/4"COLD
(84mm)
HOT 5-1/4" (133mm)
HOT 5-1/4" (133mm)
Internal Freeze Protection
Power Vent or Power Direct Vent Design
Warranty
510 Models
ANSI Z21.10.3
CSA 4.3
• 15-year limited warranty on heat exchanger in
residential applications.
• 10-year limited warranty on heat exchanger in
commercial applications.
Model
Number*
Type
Inlet Gas Pressure
Maximum
Minimum Maximum
BTU/H
in. W.C.
in.W.C.
Energy
Hot/Cold
Gas
Factor
Connections Connection
(EF)
Indoor Models
ATI-110-N
Natural 140,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
ATI-310-N
Natural 190,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
ATI-510-N
Natural 199,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
• 5-year warranty on all parts.
Model
Number*
Type
Sizing Chart
(Number of Showers)
Clearance (Inches)
Cold
Warm
Top Bottom Side Front Back
Climate** Climate***
Indoor Models
ATI-110-N
Natural
1.5
2
12
12
2
4
0.5
ATI-310-N
Natural
2
3
12
12
2
4
0.5
ATI-510-N
Natural
2.5
3.5
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example:ATI-110-P)
For outdoor models change “I” to “O” in the model number (example: ATO-110-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
40
41
INDOOR MODEL
∅4 (101 mm)
Ultra-Low NOx Emissions
Maximum Flow Rates Up To 10.0 GPM
1-3/8" (36 mm)
20-1/4" (520mm)
• Complies with SCAQMD 1146.2 NOx emission
requirements of 14 ng/J or 20 PPM.
4-3/8" (113 mm)
19-3/8" (493 mm)
3-5/8" (94 mm)
13-3/4" (350 mm)
10" (254 mm)
7" (180 mm)
2-1/4" (58 mm)
RESIDENTIAL GAS
TANKLESS NON-CONDENSING
ULTRA-LOW NOx
Copper Primary Heat Exchanger
1-7/8" (47 mm)
HOT 4-5/8" (116 mm)
OUTDOOR MODEL
13-3/4" (350 mm)
5" (128 mm)
120 VAC 1-1/2" (37 mm)
• Easy-Link Up To 4 Units.
• Multi-Link Up to 20 Units.
Safety Features
13-1/8" (334 mm)
5-1/8" (130 mm)
19-3/8" (493 mm)
ATI-510U / ATO-510U Can be Used
in Both Residential and Commercial
Applications
COLD 4-7/8"3-5/8"
(124 (94
mm)
mm)
GAS7"1-1/2"
(38 mm)
(203 mm)
4-3/8" (113 mm)
• Include a Wall Mount Temperature Remote
Controller and Advanced Diagnostics to Simplify
Troubleshooting.
10" (254 mm)
7" (180 mm)
20-1/4" (520 mm)HOT 5" (127 mm)
HOT 4-5/8" (119 mm)
Indoor/Outdoor Models
1" (26 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
COLD 6" (153 mm)
HOT 6" (153 mm)
9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
120 VAC 1-7/8" (49 mm)
1-5/8" (43 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
• Primary heat exchange of the ATI/ATO-510U is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperatures quicker and reducing
pressure drop across the heat exchanger indoor and
outdoor models available.
1" (26 mm)
120 VAC 3" (75 mm)
GAS 5-1/4" (135 mm)
COLD 6" (153 mm)
HOT 6" (153 mm)
9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm)
COLD 1-5/8" (41 mm)
GAS 5" (127 mm)
1-7/8" (47 mm)
HOT 4-5/8" (116 mm)
• Air-fuel ratio (AFR) Sensor.
• Exhaust & Water Temperature Safety Control.
Internal Freeze Protection
13-1/8" (334 mm)
Inlet Gas Pressure
Type
Energy
Maximum
Hot/Cold
Gas
Minimum Maximum Factor
BTU/H
Connections Connection
(EF)
in.W.C.
in. W.C.
Power Vent or Power Direct Vent Design
Indoor Models
Warranty
5.0
10.5
0.82
3/4” NPT
3/4” NPT
ATI-310U-N
Natural 190,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
ATI-510U-N
Natural 199,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
• 15-year limited warranty on heat exchanger in
residential applications.
• 5-year limited warranty on heat exchanger in
commercial applications.
• 5-year limited warranty on all parts.
ANSI Z21.10.3
Model
Number*
COLD 4-7/8" (124 mm)
GAS 1-1/2" (38 mm)
ATI-110U-N
Natural 140,000
120 VAC 1-7/8" (49 mm)
GAS 4-1/4" (109 mm)
COLD 5" (127 mm)
510U Models
HOT 4-5/8" (119 mm)
HOT 5" (127 mm)
• Overheat cut-off fuse.
120 VAC 1-1/2" (37 mm)
Model
Number*
Type
Sizing Chart
(Number of Showers)
Clearance (Inches)
Cold
Climate**
Warm
Climate***
Top
Bottom Side
Front
Back
Indoor Models
ATI-110U-N
Natural
1.5
2
12
12
2
4
0.5
ATI-310U-N
Natural
2
3
12
12
2
4
0.5
ATI-510U-N
Natural
2.5
3.5
12
12
2
4
0.5
*Available in Natural Gas only
For outdoor models change “I” to “O” in the model number (example: ATO-110U-N)
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
42
43
RESIDENTIAL ELECTRIC
VOLTEX® HYBRID ELECTRIC
HEAT PUMP
Increased Energy Efficiency
• Improved efficiency designed in, to ensure available
hot water at the lowest possible cost.
• Up to a 3.24 Energy Factor (EF) Rating conserves
energy and meets ENERGY STAR® qualifications.
Dual Voltage Capable
• 208/240 VAC 60Hz capable for use in almost any
residential installation.
Choice of Operating Modes
• Select from Efficiency, Hybrid, or Electric modes
to match heating requirements to environmental
conditions and hot water demand. Hybrid mode
automatically adjusts between compressor and
element, depending upon heat requirements.
• Vacation mode reduces operating costs and provides
freeze protection during extended absence.
A
B
C
E
Backup Electric Elements
• Long-lasting 4500W backup heating elements help
heat water according to environmental conditions,
demand, and the chosen operating mode.
Dry Fire Protection
• Control system checks to ensure the tank is full
of water during start up to prevent dry firing the
heating elements.
D
Electronic User Interface
• User-friendly electronic interface allows easy control
of temperature setting, operating mode, and
communicates diagnostics.
• Easy to read temperature display shows temperature
in °F or °C.
• Advanced diagnostics convey error messages for
service purposes. The last four error messages are
saved in the control system memory.
Other Features
• Ideal for basements or garage installations; the
compressor transfers heat to the water while
dehumidifying and cooling the ambient air.
• Washable air filter is easily removed for routine
cleaning.
10-Year Limited Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model
Number
HPTU-50
HPTU-66
HPTU-80
Model
Number
HPTU-50
HPTU-66
HPTU-80
Gallon
Capacity
50
66
80
1st Hour Rating (Gal)
By Mode
Energy Factor by Mode
Efficiency Hybrid Electric Efficiency Hybrid Electric
3.61
3.44
3.27
3.24
3.17
3.06
0.93
0.92
0.92
44.4
62.5
76.3
70
80
95
Dimensions in Inches
57.3
78.6
90.1
A
B
C
D
E
Approx.
Shipping
Weight (lbs)
63
61
69
22
27
27
40-5/8
38
46
3-3/4
4
4
40-1/2
38
46
196
289
307
Requires 30 amp breaker.
Top T&P option not available on this model.
44
45
RESIDENTIAL ELECTRIC
VOLTEX® LEGACY HYBRID ELECTRIC
HEAT PUMP
Increased Storage
• High capacity storage tank enables the heat pump
to operate more frequently than backup heating
elements. This improves energy efficiency and lowers
operating costs, saving more money than lower
capacity unit.
• High capacity storage tank provides more hot water
for peak demand periods.
Energy Efficiency
• Up to a 2.33 Energy Factor (EF) Rating conserves
energy and meets ENERGY STAR® qualifications.
A
Choice of Operating Modes
• Select from efficiency, hybrid, or electric modes
to match heating requirements to environmental
conditions and hot water demand. Hybrid mode
automatically adjusts between compressor and
element, depending upon heat requirements.
Vacation mode reduces operating costs and provides
freeze protection during extended absence.
E
C
Backup Electric Elements
• Long-lasting,240VAC incoloy heating elements,
2000W lower and 4500W upper, help heat water
when in conventional Electric or Hybrid modes.
D
Dry Fire Protection
• Control system ensures the tank is full of water
during start up, to prevent dry firing the heating
elements.
Electronic User Interface
• User-friendly LCD touch-pad control, with plain
English text and intuitive status icons provides easy
interaction.
• Large LCD temperature display (see back) shows
temperature in °F or °C.
• 3 line, 13 character back-lit LCD display
communicates current set point, status and
operational information.
Energy Factor by Mode
Model
Number
Gallon
Capacity
Efficiency*
Hybrid
Electric
Approx. Shipping
Weight (lbs)
• Advanced diagnostics convey error messages in plain
English. The last four error messages are saved in the
control system memory.
HHPT-80
80
2.30
2.33
0.85
340
• Child resistant safety lock deters unwanted access to
temperature and operational settings.
Model
Number
Accessory Inlet/Outlet Duct Kits with
Booster Fan (Part Numbers: 9910005000,
9910006000, & 9910057000)
HHPT-80
1st Hour Rating (Gal) By
Mode
Efficiency Hybrid Electric
70
84
76
Dimensions in Inches
A
B
82-1/2 24-1/2
C
55
D
E
4-1/4 56-1/3
Requires 30 amp breaker.
Top T&P option not available on this model.
6-Year Limited Warranty
46
• For complete information, consult written warranty
go to hotwater.com
47
RESIDENTIAL ELECTRIC
VOLTEX® HYBRID ELECTRIC
HEAT PUMP
Increased Energy Efficiency
• Improved efficiency designed in, to ensure available
hot water at the lowest possible cost.
• Up to a 2.75 Energy Factor (EF) Rating conserves
energy and meets ENERGY STAR® qualifications.
Choice of Operating Modes
• Select from Efficiency, Hybrid, or Electric modes
to match heating requirements to environmental
conditions and hot water demand. Hybrid mode
automatically adjusts between compressor and
element, depending upon heat requirements.
• Vacation mode reduces operating costs and provides
freeze protection during extended absence.
A
Backup Electric Elements
• Long-lasting 4500W backup heating elements help
heat water according to environmental conditions,
demand, and the chosen operating mode.
B
C
E
Dry Fire Protection
• Control system checks to ensure the tank is full
of water during start up to prevent dry firing the
heating elements.
Electronic User Interface
• User-friendly electronic interface allows easy control
of temperature setting, operating mode, and
communicates diagnostics.
D
• Easy to read temperature display (see back) shows
temperature in °F or °C.
• Advanced diagnostics convey error messages for
service purposes. The last four error messages are
saved in the control system memory.
Other Features
• Ideal for basements or garage installations; the
compressor transfers heat to the water while
dehumidifying and cooling the ambient air.
• Washable air filter is easily removed for routine
cleaning.
Model Gallon
Number Capacity
Efficiency Hybrid
FHPT-80
2.78
2.71
2.71
Model
Number
A
B
C
D
E
Approx.
Shipping
Weight (lbs.)
63
61
69
22
27
27
40-5/8
38
46
3-3/4
4
4
40-1/2
38
46
196
285
302
FHPT-66
FHPT-50
FHPT-66
FHPT-80
2.75
2.74
2.72
Electric Efficiency Hybrid Electric
50
66
80
FHPT-50
6-Year Limited Warranty
• For complete information, consult written warranty
or go to hotwater.com.
1st Hour Rating (Gal)
by Mode
Energy Factor by Mode
0.89
0.91
0.92
42.1
59.7
71
67.5
81
90
Dimensions in Inches
59.1
79
88
Requires 30 amp breaker.
Top T&P option not available on this model.
48
49
INTERFACE
RESIDENTIAL ELECTRIC
CONSERVATIONIST
ACCESS
SELF-CLEANING
ANODE
SMART PORT
MODULE
CONNECTION
PANEL
Electronic User Interface
• Touchscreen display.
DRAIN
VALVE
T&P VALVE
• Multiple operating modes help save money.
• Energy Saver and vacation modes available.
• Diagnostic feedback.
JUNCTION BOX
• Dry fire protection.
• Grid management ready.
T&P VALVE
• CEA-2045 Bridge module compatible.
Enhanced Heating Elements
ACCESS
PANEL &
USER
INTERFACE
• Dual 5500 watt elements for the fastest recovery
and reliable operation.
• Incoloy stainless steel elements last longer than
standard copper elements.
ENERGY
SMART
S TANDARD
VAC ATION
GRID
ENABLED
F
°F/°C
Enhanced-Flow Brass Drain Valve
Code Compliance
ACCESS
PANEL
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
DRAIN
VALVE
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Approved for Manufactured Housing
• All residential electric water heaters are compliant
with HUD standards for mobile homes/manufactured
housing.
Design-Listed by Underwriters
Laboratories
Model
Number
Gallon
Capacity
First Hour
Rating Gallon
Energy
Factor
Recovery
@ 90˚F Rise
Gallon Per
Hour
Approx.
Shipping
Weight (lbs)
40
50
55
61
79
79
0.95
0.95
0.94
25
25
25
118
134
145
40
50
56
58
0.95
0.95
25
25
109
161
Tall Models
PXNT-40
PXNT-50
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
PXNT-55
• Listed according to UL 174 standards governing
storage tank-type electric water heaters.
PXNS-40
Short Models
PXNS-50
10-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model
Number
Element Wattage 240V
Dimensions in Inches
Standard
Maximum
A
B
C
5500
5500
5500
6000
6000
6000
60-1/4
60-1/2
56-1/2
53-1/4
51-1/4
48-1/2
20
22
24
5500
5500
6000
6000
50
49-3/4
40-3/4
40-1/4
22
24
Tall Models
PXNT-40
PXNT-50
PXNT-55
Short Models
PXNS-40
PXNS-50
50
Only available for 240V or 208V applications.
Equipped as dual element only; no single element configurations available.
Top T&P option not available on these models.
¾” water connections on 8” center.
51
RESIDENTIAL ELECTRIC
PROMAX® STANDARD
Model
Number
Enhanced Heating Elements
• Dual 4500 watt elements for the fastest recovery
and reliable operation.
• Incoloy stainless steel lower element lasts longer
than standard copper elements.
High Energy Factors
Dynaclean™ Diffuser Dip Tube
Recovery @ 90°F
Approx.
Gallon
First Hour
Energy
Rise Gallon Per
Shipping
Capacity Rating Gallon Factor
Hour
Weight (lbs)
Tall Models
ENT-30†
ENT-40†
ENTB-50*
ENT-50†
ENT-55†
30
40
50
50
55
47
51
70
71
76
0.95
0.95
0.95
0.95
0.94
21
21
21
21
21
95
118
131
134
145
30
30
40
50
48
49
55
62
0.95
0.95
0.95
0.95
21
21
21
21
95
94
109
161
N/A
0.95
0.95
0.95
0.95
21
21
21
21
21
65
96
115
118
118
Short Models
ENSB-30*
ENS-30†
ENS-40†
ENS-50†
Coregard Anode Rod
™
Code Compliance
• Meets UBC, CEC and HUD National Codes.
Lowboy Top Connect Models
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
ENL-20
ENLB-30*
ENL-30†
ENLB-40*
ENL-40†+
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Approved for Manufactured Housing
• All residential electric water heaters are compliant
with HUD standards for mobile homes/manufactured
housing.
Model
Number
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to UL 174 standards governing
storage tank-type electric water heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
N/A
40
43
46
44
Element Wattage 240V
Dimensions in Inches
Standard
Maximum
A
B
C
4500
4500
4500
4500
4500
6000
6000
6000
6000
6000
46-1/2
60-1/4
60-1/4
60-1/2
56-1/2
39-1/2
53-1/4
51-1/4
51-1/4
48-1/2
19
20
21
22
24
4500
4500
4500
4500
6000
6000
6000
6000
39
39-3/4
50
49-3/4
30-1/2
30-1/2
40-3/4
40-3/8
20
22
22
24
N/A
6000
6000
6000
6000
30
30
31-1/4
31-3/4
33-1/2
21-1/4
21-3/4
21-3/4
24
24
20
22
24
24
26
Tall Models
ENT-30†
ENT-40†
Design-Listed by Underwriters
Laboratories
19.5
28
28
38
38
ENTB-50*
ENT-50†
ENT-55†
Short Models
ENSB-30*
ENS-30†
ENS-40†
ENS-50†
Lowboy Top Connect Models
ENL-20
ENLB-30*
ENL-30†
ENLB-40*
ENL-40†+
T&P
VALVE
T&PVALVE
ACCESS
ACCESS
PANEL
PANEL
ANODE
ANODE
JUNCTION
JUNCTION
BOX
BOX
ACCESS
ACCESS
PANEL
PANEL
DRAIN
DRAIN
VALVE
VALVE
52
4500
4500
4500
4500
4500
* Models ship with supplied insulation blanket.
† For 10-year tank and 6-year parts warranty, change "E" to "P" in the model number
(example: ENT-30 becomes PNT).
+ Top T&P option not available on this model.
¾” water connections on 8” center.
ENL-20 is a single element configuration only
T&P
T&PVALVE
VALVE
53
RESIDENTIAL ELECTRIC
PROMAX® MOBILE HOME
Approved for Manufactured Housing
• All residential electric water heaters are compliant
with HUD standards for mobile homes/manufactured
housing.
ANODE
C
JUNCTION
BOX
Side Water Connections
T&P VALVE
• For ease of installation in mobile home applications.
Coregard Anode Rod
™
WATER CONNECTIONS
• Our anode rods have a stainless steel core that
extends the life of the anode rod allowing superior
tank protection far longer than standard anode rods.
Long-Lasting Heating Elements
T&P VALVE
• Screw-in, direct immersion, 3500W/240V or
3000W/120V heating elements for maximum
efficiency.
OUTLET
Blue Diamond® Glass Coating
Enhanced-Flow Brass Drain Valve
• Our residential water heaters have a solid brass,
tamper resistant, enhanced-flow, ball type, drain
valve.
C
E
• Uses a standard female hose fitting that allows for
fast and easy draining during maintenance.
CSA Certified and ASME Rated T&P Relief
Valve
INLET
• Meets UBC, CEC and HUD National Codes.
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
• Complies with the Federal Energy Conservation
Standards effective April 16, 2015, in accordance
with the Energy Policy and Conservation Act (EPCA),
as amended.
Design-Listed by Underwriters
Laboratories
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
• Listed according to UL 174 standards governing
storage tank-type electric water heaters.
6-Year Limited Tank and Parts Warranty
• For complete information, consult written warranty
or go to hotwater.com.
Model Number
MHE6-30H-030D
MHE6-30H-035D
MHE6-40R-030D
MHE6-40R-035D
MHE6-30L-030D*
MHE6-30L-035D*
MHE6-30H-030D
MHE6-30H-035D
MHE6-40R-030D
MHE6-40R-035D
MHE6-30L-030D*
MHE6-30L-035D*
54
First
Gallon Hour
Capacity Rating
Gallon
30
30
40
40
28
28
42
42
51
51
40
40
Recovery
Approx.
Energy @ 90˚F Rise
Shipping
Voltage
Factor Gallon Per
Weight
Hour
(lbs)
0.95
0.95
0.95
0.95
0.95
0.95
Wattage
Model Number
A
DRAIN
VALVE
D
Code Compliance
B
Upper Lower
Element Element
3000
3500
3000
3500
3000
3500
14
16
14
16
14
16
120
240
120
240
120
240
98
98
109
109
96
96
Dimensions in Inches
A
B
3000 46-3/4 39-1/2
3500 46-3/4 39-1/2
3000
50 40-3/4
3500
50 40-3/4
3000
30 21-3/4
3500
30 21-3/4
C
D
E
19
19
22
22
22
22
3-7/8
3-7/8
4-3/8
4-3/8
4-1/2
4-1/2
39-5/8
39-5/8
41
41
22
22
* Models ship with supplied insulation blanket.
MHE6 models may have limited element options due to element size or other restrictions.
Available with side T&P only.
¾” water connections.
55
RESIDENTIAL ELECTRIC
PROMAX® SPECIALTY
ELECTRIC
Approved For Manufactured Housing
• All residential electric water heaters are
compliant with HUD standards for mobile
homes/manufactured housing.
Table-Top
• Features a convenient flat porcelain surface at
36" height, providing extra "counter space"
wherever installed. All plumbing and electrical
connections are made through the back of
the water heater. This heater is equipped with
a PEX cross-linked polymer dip tube.
Point-of-Use
• Designed for low-demand, such as office
lavatories or buildings with remote rest
rooms.
LOWBOY
Compact
• Side-mounted plumbing and electrical
connections (optional top-mounted water
connections for field conversion). Designed
for installation under a counter, in a crawl
space or in other tight spaces.
Code Compliance
TABLE TOP
EJC-10
EJCS-20
EJCT-20
• Meets the thermal efficiency and standby
loss requirements of the U.S. Department
of Energy and current edition of ASHRAE/
IESNA 90.1.
• Listed according to UL 174 standards
governing storage tank-type electric water
heaters.
6-Year Limited Tank And Parts
Warranty
• For complete information, consult written
warranty or go to hotwater.com.
Energy
Factor
Element Wattage
Standard
ENJB-40*
ENJ-40
240V
3000
6000
6000
6000
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1650
1650
2500
2500
28
28
38
38
39
39
47
44
0.95
0.95
0.95
0.95
4500
4500
4500
4500
38
45
0.88
4500
240V
Table Top Model
ESTT-40
Model
Number
6000
6000
6000
6000
240V
Point-Of-Use-Models
5500
120V
2.5
EJC-2
Maximum
120V
Lowboy Side-Connect Model
ENJ-30
• Certified at 300 PSI test pressure and 150 PSI
working pressure.
First Hour Rating
Gallon
6
10
19
19.9
EJC-6
• Meets UBC, CEC and HUD National Codes.
• Complies with the Federal Energy
Conservation Standards effective April 16,
2015, in accordance with the Energy Policy
and Conservation Act (EPCA), as amended.
Gallon
Capacity
Compact Models
ENJB-30*
Design-Listed By Underwriters
Laboratories
COMPACT
Model
Number
N/A
Recovery @ 90˚F
Rise Gallons Per
Hour
N/A
1500 @ 120V
Dimensions in Inches
A
B
C
Approx.
Shipping
Weight (lbs)
15-1/4
18-1/4
24-3/4
31-5/8
10-3/4
12-1/4
18-5/8
25-3/4
14-1/4
16
18
16
35
41
68
68
21
21
21
21
30
31-1/4
31-3/4
33-1/2
21-3/4
21-3/4
24
24
22
24
24
26
101
115
118
118
21
36
24
25
150
7
13-3/4
11
13-3/4
20
Compact Models
EJC-6
EJC-10
EJCS-20
EJCT-20
8
8
11
11
Lowboy Side-Connect Model
ENJB-30*
ENJ-30
ENJB-40*
ENJ-40
Table Top Model
POINT-OF-USE
ESTT-40
Point-Of-Use-Models
EJC-2
56
*Models ship with supplied insulation blanket.
57
RESIDENTIAL
PUMP TANKS
Dimensions in Inches
Certified to NSF/ANSI
61-G and 372
ultiple Head Construction Adds Structural Strength and More
M
Capacity within the Same Diameters
• Interior powder coating is permanently bonded to the tank shell for ultimate protection
on the water side of the tank.
• Butyl rubber parabolic diaphragm.
• Positive lock retention system controls compression in the diaphragm connection,
eliminating air loss or water leaks in tank.
• Electrostatically applied powder-coated exterior for maximum sunlight (UV) resistance
with zinc phosphate undercoat for highest corrosion resistance.
Model
Number
PMI-2
PMI-5
PMI-7
PMI-14
PM-14
PM-20
PM-26
• PM-32
• 5-year limited warranty.
Overall
Height -A
Weight
To Center
of Water Diameter-B (lbs.)
Inlet
PMI (Inline) and PM (Free-Standing) Series
• Corrosion-resistant metal air valve.
No-weld steel base
Volume Connecting
(Gallons) NPT Size
PM-45
PM-65
PM-85
PM-86
PM-119
2.0
4.6
7.3
13.9
13.9
19.9
25.9
31.8
45.2
65.1
84.9
83.5
115.9
3/4 (M)
3/4 (M)
3/4 (M)
1 (M)
1 (F)
1 (F)
1 (F)
1 (F)
1-1/4 (F)
1-1/4 (F)
1-1/4 (F)
1-1/4 (F)
1-1/4 (F)
Horizontal Series
PMH-7
PMH-14
PMH-20
7.3
13.9
19.9
10-3/16
14-3/4
21-1/16
21-1/16
24-15/16
32-3/8
39-9/16
47-1/4
36-9/16
48-5/8
60-11/16
46
61-5/16
2
2
2
2
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
Length-A
3/4 (M)
1 (M)
1 (M)
12-7/8
18-1/4
18-1/4
8-1/4
11
11
15-3/8
15-3/8
15-3/8
15-3/8
15-3/8
22
22
22
26
26
5
9
14
24
24
34
43
52
65
90
114
116
161
Diameter-B
-
11
15-3/8
15-3/8
16
25
36
NOTE: M-Male connection
F-Female connection
All models 38 PSI pre-charge
58
59
RESIDENTIAL
EXPANSION TANKS
Model
Number
Maximum (PSIG)
Working Pressure
Tank
Volume
(Gallons)
Maximum Accepted Volume
(Gallons)
20 PSI
40 PSI
60 PSI
PMC-Series (Potable Expansion Tanks - 5-Year Limited Warranty)
PMC-2
PMC-5
PMC-10
150
150
150
1.96
4.55
9.25
1.53
3.75
7.80
1.27
3.05
6.55
1.03
2.19
5.25
TW-Series (Potable Expansion Tanks - 1-Year Limited Warranty)
Certified to NSF/ANSI
61-G and 372
When used in
potable applications
TW-5
TW-12
2.10
4.40
1.53
3.75
1.27
3.05
1.03
2.19
PMET-Series (Hydronic Expansion Tanks - 1-Year Limited Warranty)
PMET-2
Interior Powder Coating is Permanently Bonded to the Tank Shell for
Ultimate Protection on the Inside of the Tank
150
150
PMET-5
PMET-7
PMET-14
100
100
100
100
1.96
4.55
7.30
14.6
1.53
3.75
4.60
10.5
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Butyl Rubber Parabolic Diaphragm
Positive Lock Retention System Controls Compression in the
Diaphragm Connection, Eliminating Air Loss or Water Leaks in Tank
Model
Number
PMC-5
PMC-10
5-Year Limited Warranty on PMC Expansion Tanks
Diameter - B
Weight
(lbs)
3/4
3/4
3/4
10-3/16
14-3/4
15-1/2
8-1/4
11
15-3/8
5
9
18
TW-Series (Potable Expansion Tanks - 1-Year Limited Warranty)
TW-5
1-Year Limited Warranty on TW Series Expansion Tanks
Dimensions in Inches
Overall Height - A
PMC-Series (Potable Expansion Tanks - 5-Year Limited Warranty)
PMC-2
Projection Welded Air Valve
Connection
NPT Size
TW-12
3/4
3/4
10-3/16
14-3/4
8-1/4
11
5
9
PMET-Series (Hydronic Expansion Tanks - 1-Year Limited Warranty)
1-Year Limited Warranty on Hydronic Expansion Tanks
PMET-2
PMET-5
PMET-7
PMET-14
60
1/2
1/2
1/2
1/2
10-3/16
14-3/4
21-1/16
23-1/2
All PMC and TW Series models 38 PSI pre-charge.
All PMET models 12 PSI pre-charge.
8-1/4
11
11
15-3/8
5
9
14
25
61
COMMERCIAL WATER SYSTEMS
iCOMM™ REMOTE MONITORING
SYSTEM
iCOMM Requirements
•Facility must have “always on” internet (wired or wireless)
•iCOMM compatible water heaters (see next page for compatible models)
What is iCOMM™ Elite?
iCOMM™ Elite utilizes the latest technology in commercial water heating to
allow us to interact with, pro-actively manage and monitor your A. O. Smith
water heaters from anywhere in the world via the Internet. With this newly
redesigned industry-exclusive service, A. O. Smith can monitor your water
heaters around the clock, alert you instantly in case of a problem, and begin
fixing any potential problems immediately. How is that for ultimate peace of
mind? (Must be ordered within 90 day or water heater installation.)
•*Annual iCOMM subscription
Who is iCOMM Elite Designed For?
•For information and ordering call 1-888-WATER02 or visit www.
aosmithconnect.com
Any commercial water heater customers, ranging from small businesses with
one water heater to national chain operations with thousands of locations.
iCOMM Features
Elite Compatible Units Include:
•Provides remote monitoring via www.aosmithconnect.com
•Cyclone® Mxi (BTH models)
•E-mail and text messaging of fault conditions
•Custom Xi (DSE models)
•Graphs unit performance and operational history
•Gold Xi (DVE models)
•BACnet compatibility with building management systems
Valet Service on Any Warranty Claim!
Compatible Products Include:
•Cyclone® Xi (Mxi, Xi and BTX(L)100 models)
•Custom® Xi (DVE-DHE models)
•Gold Xi (DVE models)
•Genesis® Domestic Water Heaters and Boilers manufactured between July
2009 and January 2014 (GB/GW models, 100-599 series)
•VF™ Variable Fire Domestic Water Heaters and Boilers manufactured between
July 2009 and January 2014 (VB/VW models, 100-299 series)
Should you experience problems with any products that are still under
warranty–it’s time for the VIP treatment. We will do everything to get you
back on track, and we mean everything. Our complete valet service includes
a call before the service, handling all the logistics, repairing the product, and
of course, superior service throughout the process.
COMPLETE COVERAGE,TOTAL PEACE OF MIND
GET iCOMM™ ELITE IN 3 EASY STEPS:
1.Confirm you have a compatible unit.
2.Verify that you have an internet
connection in the same room as the
water heater(s).
3.Call 1-888-WATER02 to purchase and
arrange installation.
HARDWARE
Model
Number
ICMA
IDMA
62
IABA
ICMA
Item
Description
iCOMM
Main communications board
Communications required for any iCOMM
installation.
Module
IMDA
iCOMM
Multi-Device
Adapter
IABA
iCOMM
Alarm Box
Needed if more than
one water heater will be
connected to the control
module. Order 1 MDA for
each water heater installed.
Accessory alarm box that
includes an audible alarm and
alarm light.
iCOMM™ Subscription (Required) Per iCOMM
Communication Module for Elite services
*iCOMM subscription is required to use the “iCOMM Elite service”. End user responsible for
paying and maintaining annual subscription. Installation and subscription service fees are
net prices paid directly by the end user. No distributor discounts are applicable.
For information and ordering call 1.888.WATER02
63
or visit www.aosmithconnect.com
COMMERCIAL WATER SYSTEMS
BUILDING MANAGEMENT SYSTEM
BACnet & MODBUS INTERFACE
INTRODUCING THE BMS
GATEWAY FOR CONTROL OF
A. O. SMITH WATER HEATERS
Connect Your A. O. Smith Water Heater to your
Building Management System Using the New
Millennium Control from ICC* (Industrial Control
Communications, Inc.)
• Works
with Cyclone, McBee DVE, Renton DSE/DVE/
DHE (Except BTX-80)
• Use the ICC Control to enable/disable the water
heater
• Change Temperature Set points and differentials
• Two models with four different configurations to
connect to BACnet and Modbus
• Ethernet and Serial RS-485 versions available
• 2 wire or 4 wire RS-485 Network
• Power can be supplied via the USB cable, as a 7-24
VDC input on the main terminal Block, or via IEEE
802.3af Power over Ethernet (PoE on ETH-1000
only)
• Configure protocols, network characteristics, and
client/server object definitions
• Graphically interact with the internal database in
real-time via USB connection
• Automatically discover and configure IP settings
Ethernet gateways connected to the current subnet
• Update Firmware
MODELS:
ETH-1000
Ethernet Connection
(Shown)
XLTR-1000
Serial RS-485 Connection
ICC Energy Management Interfaces
Protocol
Part Number
991009300
BACnet
991009400
Connection
Type
Serial
(RS485)
Application
Commercial Gas - Cyclone®
BTH and BTX (L)-100
Commercial Electric DSE,
DVE, DHE
Commercial Gas - Cyclone®
BTH and BTX (L)-100
Ethernet (IP)
Commercial Electric DSE,
9910100000
DVE, DHE
Commercial Gas - Cyclone®
9910096000
BTH and BTX (L)-100
Serial
(RS485)
Commercial Electric DSE,
9910097000
DVE, DHE
991009900
Modbus
991010200
Ethernet (IP)
9910103000
Commercial Gas - Cyclone®
BTH and BTX (L)-100
Commercial Electric DSE,
DVE, DHE
• Heater connection wiring supplied with unit
• For questions on this product Call 888-928-3702 Opt 1
• RTU and serial connect via RS-485
• Ethernet and IP connect via RJ-45
64
65
T & P VALVE
COMMERCIAL GAS
CYCLONE® HE
SIDE
OUTLET
H
ANODE
Power Vent Design A
for Installation
Versatility
HOT
B
G
DIAMETER
• Modular blower, with 120 volt, 60Hz electrical
system (5 amps or less), 6-foot cord with standard
SIDE INLET
3-prong connector
J
C
TOP VIEW
• Combined vertical and horizontal runs terminating
THERMOSTAT
through an outside wall, using Schedule
40 PVC,
DRAIN
CPVC or ABS or polypropylene pipe: Canadian
VALVE
installations require ULC S636 approved pipe for
venting
• 2” pipe allows ventF
runs up to 25
equivalent feet
K
COLD
* INSTALL IN ACCORDANCE WITH LOCAL CODES
D
OUTLET
INLET
E
• 3” pipe allows vent runs up to 65FRONT VIEW
equivalent feet
SIDE
OUTLET
T & P VALVE
• 4” pipe allows vent runs up to 128
equivalent feet
ANOD
High Output with Small Footprint
• 22” diameter, combined with 90% efficiency,
50-gallon tank and 76,000 BTU input means
Cyclone® HE can be installed in less space than
a larger 75-gallon unit, with equal or better
performance.
A
B
G
DIAMETER
Side-Mounted Hot and Cold
Recirculating Taps
J
C
SIDE INLET
Two Heavy-Duty Anode Rods
THERMOSTAT
3-Year Limited Tank and 1-Year Limited
Parts Warranty
F
• For complete warranty information, consult written
warranty or go to hotwater.com.
* INSTALL IN
DRAIN
VALVE
D
E
FRONT VIEW
Model
Number
BTX-80
Recovery Capacity
GPH @ 100°F Rise
BTU Input
Per Hour
Approx.
Shipping Weight
(lbs)
50
92
76,000
210
Dimensions in Inches
Model
Number
A
B
C
D
E
BTX-80
71
68-5/8
52
21
9-1/8
F
G
H
J
K
12
22
8
15-3/4
27
Model
Number
BTX-80
66
Gallon
Capacity
Dimensions in Inches
Available in Natural Gas only.
Standard model certified from sea level to 5,300 ft. elevation. Order SMR S54 for elevations
to 10,100 ft.
Optional Condensate Neutralization Kits available (Part Number 9007959005).
67
COMMERCIAL GAS
CYCLONE® Xi
Helical Internal Heat Exchanger
• Spiral heat exchanger keeps hot combustion gases in
the tank longer to lengthen the heat transfer cycle
ANODE
• Positioned in the center of the tank for more even
heat distribution
F
• Operates at 96% thermal efficiency, which saves
money on operating costs compared to a standard
80% efficient gas water heater
BTX-100
AN
Power Direct Vent Design
OUTLET
• Combined vertical and horizontal runs terminating
through an outside wall. Vents using PVC, CPVC,
ABS or polypropylene piping. Canadian installations
require ULC S636 approved pipe for venting.
INLET
TOP VIEW
INSTALL IN ACCORDANCE WITH LOCAL CODES.
3” DIAMETER
VENT/EXHAUST
• 2” pipe, vents up to 45 equivalent feet
• 3” pipe, vents up to 128 equivalent feet
OUTLET
Condensing Design
• 96% efficient condensing design
1 3/ 16 ”
• Equipped with condensate drain tee
4 1/2” DI AMET ER
INSTALL IN AC
1 1/2”
21 1/8”
3-Year Limited Tank and 1-Year Limited
Parts Warranty
3” DIAMETER
VENT/EXHAUST
N AI R
39”
3” DIAMETER PVC
INTAKE/COMBUSTIO
• For complete warranty information, consult written
warranty or go to hotwater.com.
OPTIONAL CONCENTRIC VENT KI
T
13
1 1/2”
3” DI
INTAK
FRONT VIEW
Model
Number
BTX-100
Model
Number
BTX-100
OPTIO
Capacity
Gallons
Recovery Capacity
GPH @ 100°F Rise
BTU Input
Per Hour
Approx.
Shipping Weight
(lbs)
50
129
100,000
255
Dimensions in Inches
A
B
C
D
E
F
66-3/4
49-1/4
22
15-3/4
3
8
Standard model certified from sea level to 10,100 ft. elevation.
Optional Concentric Vent Kits (9006328005) and Condensate Neutralization Kits
(9007959005).
Specify when ordering propane (LP) gas.
68
69
COMMERCIAL GAS
CYCLONE® Xi
Helical Internal Heat Exchanger
• Spiral heat exchanger keeps hot combustion gases in
ANODE
the tank longer to lengthen the heat transfer cycle
• Positioned in the center of the tank for more even
heat distribution
F
BTXL-100
• Operates
at 96% thermal efficiency, which saves
BTX-100
money on operating costs compared to a standard
80% efficient gas water heater
ANODE
OUTLET
Power Direct Vent Design
INLET
TOP VIEW
F
• Combined vertical and horizontal runs terminating
ACCORDANCE WITH LOCAL CODES.
through an outside wall. Vents usingINSTALL
PVC<INCPVC,
ABS or polypropylene piping.
Canadian installations
3” DIAMETER
VENT/EXHAUST
require ULC S636 approved
pipe for venting.
OUTLET
• 2” pipe, vents up to 45 equivalent feet
INLET
TOP VIEW
• 3” pipe, vents up to 128 equivalent feet
1 3/ 16 ”
Condensing Design
1 1/2”
• 96% efficient condensing design
4 1/2” DI AMET ER
INSTALL IN ACCORDANCE WITH LOCAL CODES.
21 1/8”
3” DIAMETER PVC
INTAKE/COMBUSTIO
• Equipped with condensate drain tee
3” DIAMETER
VENT/EXHAUST
N AI R
39”
OPTIONAL CONCENTRIC VENT KI
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com.
FRONT VIEW
TOP VIEW
T
4 1/2” DI AMET ER
1 3/ 16 ”
1 1/2”
21 1/8”
3” DIAMETER PVC
INTAKE/COMBUSTIO
N AI R
39”
OPTIONAL CONCENTRIC VENT KIFRONT
T
Model
Number
BTXL-100
Model
Number
BTXL-100
VIEW
Capacity
Gallons
Recovery Capacity
GPH @ 100°F Rise
BTU Input
Per Hour
Approx.
Shipping
Weight (lbs)
75
129
100,000
382
Dimensions in Inches
A
B
C
D
E
F
65-1/4
45-5/8
27-3/4
16
3-3/4
8
Standard model certified from sea level to 10,100 ft. elevation.
Optional Concentric Vent Kits (9006328005) and Condensate Neutralization Kits
(9007959005).
Specify when ordering propane (LP) gas.
70
71
COMMERCIAL GAS
CYCLONE® MXi
Up to 98% Efficient
Intelligent Control System with LCD
Display
• Exclusive A. O. Smith designed control system
• Provides detailed water heater status information
• Precise temperature control adjustable from 90 to
180 degrees
• Built-in diagnostics
• Run history information
• Cyclone water heaters are compatible with
the iCOMM™ remote monitoring system. Call
1.888.928.3702 for more information.
Submerged Combustion Chamber, with
Helical Heat Exchanger Coil
Model
Number
Gallon
Capacity
Input
BTU/HR
BTH-120(A)
60
100
100
100
119
119
119
120,000
150,000
199,900
250,000
119,000
119,000
119,000
BTH-150(A)
BTH-199(A)
BTH-250(A)
BTH-300(A)
BTH-400(A)
BTH-500(A)
Approx.
Approx.
Shipping Weight Shipping Weight
(lbs) Std
(lbs) ASME
460
523
523
523
855
855
855
490
553
553
553
855
855
855
Optional Concentric Vent Kits 9006328005 (BTH-120 through BTH-250 models).
9008841005 (BTH-300 through BTH-500 models).
Electrical characteristics- 120V-60 Hz A.C., 5.0A.
“A” in the model number represents ASME construction.
Models are certified from sea level to 10,100 ft. elevation.
• Positioned in center of tank, surrounded by water
to virtually eliminate radiant heat loss from
chamber
• Direct spark ignition
• Spiral heat exchanger keeps hot burner gases
swirling, uses centrifugal force to maximize
efficiency of heat transfer to water in tank
• Spiral heat exchanger reduces lime scale from
forming on water-side surfaces, which maintains
energy efficiency over time
Power Anodes Standard on All Models
(For 300, 400
& 500 Models)
(For 120-150
Models)
• Provides long-lasting tank protection in varying
water conditions
• Powered anodes are non-sacrificial
• Automatically adjusts output needed to properly
protect the tank
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com
Line drawings and dimensions on the following page.
72
73
FRONT
T
T&
PV
AL
VE
C
LE
AN
US
HA
EX
IN
DRA E
VALV
O
U
T
COMMERCIAL GAS
CYCLONE® MXi (CONTINUED)
18°
42°
30°
45°
* Center line of water outlet on top of the water heaters is
approximately 7 inches from the front edge of the water heater.
T&P
FRONT
ALL MODELS
S
E
1 1/2” NPT
WATER
INLET
AIR
AK
INT
26°
3/4” NPT
DRAIN
C
A
J
G
3/4" NPT RECIRC
RETURN
4" EXHAUST VENT
CONNECTION
C
1 1/2" SUPPLY
GAS CONNECTION
1 1/2" NPT
WATER
OUTLET
4" PVC AIR INTAKE
GAS CONNECTION
U
T
WATER
OUTLET HEIGHT
T
O
AN
T&
PV
AL
VE
C
LE
US
HA
EX
N
DRAI E
VALV
WATER
OUTLET
HEIGHT
18°
45°
BACK
T & P VALVE
D
B
LOWER
TEMPERATURE
PROBE
CLEANOUT
E
3/4” NPT
RECIRCULATION
RETURN
VENT
CONNECTION
3 INCH PVC
(exhaust elbow)
1 1/2” NPT
WATER
INLET
3/4” NPT
DRAIN
C
J
G
BTH-250(A)
A
Dimensions in Inches
INTAKE AIR
CONNECTION
3 INCH PVC
B
3
3
3
3
27.75
27.75
27.75
27.75
SUPPLY GAS
CONNECTION
C
D
6.3
6.3
6.3
6.3
35
56.38
BACK
56.38
56.38
I
Model
Number
BTH-120(A)
BTH-150(A)
BTH-199(A)
BTH-250(A)
E
WATER
OUTLET
HEIGHT
55.5
76
76
E 76
F
H
Dimensions in Inches
Model
Number
BTH-300(A)
BTH-400(A)
BTH-500(A)
Model
Number
F
G
H
I
J
BTH-300(A)
53.5
75.75
75.75
75.75
11.25
11.25
11.25
11.25
42.25
64
64
64
48.5
70
70
70
18.25
18.25
18.25
18.25
BTH-400(A)
Optional Concentric Vent kit 9008841005 (BTH-300 through BTH-500 models).
Electrical characteristics- 120V-60 Hz A.C., 5.0A.
“A” in the model number represents ASME construction.
Models are certified from sea level to 10,100 ft. elevation.
74
I
FRONT
F
A
H
B
E
H
42°
FRONT
45°
* Center line of water outlet on top of the water heaters is
approximately 7 inches from the front edge of the water heater.
F
BTH-199(A)
18°
30°
42°
30°
BACK
BTH-150(A)
TOP
T
US
HA
EX
FRONT
INTAKE AIR
CONNECTION
3 INCH PVC
BTH-120(A)
INT
AKE
1½" NPT WATER
OUTLET
SUPPLY GAS
CONNECTION
Model
Number
J
G
1 1/2" NPT
WATER INLET
A
I
20°
70°
3/4" NPT DRAIN
90°
GA
CLEANOUT
VENT
CONNECTION
3 INCH PVC
(exhaust elbow)
CLEANOUT
D
TOP VIEW
GAS
LOWER
TEMPERATURE
PROBE
E
DRA
IN
B
3/4” NPT
RECIRCULATION
RETURN
CL
EA
NO
UT
D
FRONT
E
T&
P
T & P VALVE
BTH-500(A)
Dimensions in Inches
A
B
C
D
E
4.75
4.75
4.75
33.12
33.12
33.12
4.75
4.75
4.75
52
52
52
75.75
75.75
75.75
Dimensions in Inches
F
G
H
I
J
73.75
73.75
73.75
12.75
12.75
12.75
63.13
63.13
63.13
69.25
69.25
69.25
23
23
23
Optional Concentric Vent kit 9008841005 (BTH-300 through BTH-500 models).
Electrical characteristics- 120V-60 Hz A.C., 5.0A.
“A” in the model number represents ASME construction.
Models are certified from sea level to 10,100 ft. elevation.
75
COMMERCIAL GAS
MASTER-FIT® BTR
The Eliminator™ Self-Cleaning System
• Designed to significantly reduce or eliminate
sediment build-up inside the tank
• Reduced sediment build-up maintains rated
thermal efficiency and reduces water heating
costs
• Self-cleaning system maximizes tank life
Factory-Installed Draft Diverter and
Automatic Flue Damper (BTR-120-400
Models)
• BTR-500 Model features induced draft design
and no damper
Model Number
BTR-120*
BTR-154
BTR-180
BTR-197
BTR-198
BTR-199
BTR-200 (A)
BTR-250* (A)
BTR-251* (A)
BTR-275* (A)
• Low-profile draft diverter helps for installation in
tight spaces
BTR-305 (A)
• Automatic motorized flue damper helps minimize
standby heat loss
BTR-400 (A)
Three Water Connection Options for
Added Flexibility
• Hot and cold water connections can be made
through front, top or rear of unit
• Eliminator™ system operates when cold water is
connected through front
BTR-365 (A)
BTR-500 (A)
Gallon
Capacity
Input BTU/HR
Natural Gas
Recovery Capacity
GPH @ 100°F Rise
71
81
81
100
100
81
100
100
65
100
65
85
100
85
120,000
154,000
180,000
199,000
199,000
199,000
199,000
250,000
251,000
275,000
305,000
365,000
390,000
500,000
116
149
175
193
193
193
193
242
243
267
296
354
378
485
Specify when ordering propane (LP) gas.
*Model BTR 120 is shipped with 6” x 5” flue outlet adapter. Models BTR 250, 251 and
275 are shipped with a 8” x 6” flue outlet adapter.
Standard models certified from sea level to 2,000 ft. elevation. Order SMR S54 for
elevations up to 8,000 ft.
BTR-500 model features induced draft design and no damper.
3-Year Limited Tank and 1-Year
Warranty
• For complete warranty information, consult
written warranty or go to hotwater.com
Line drawings and dimensions on the following page.
76
77
COMMERCIAL GAS
MASTER-FIT® BTR (CONTINUED)
Master-Fit BTR 120-400
INDUCED DRAFT MOTOR
I
1˝ NPT
RELIEF
VALVE
OPENING
I
Model
Number
Dimensions in Inches
A
B
C
D
E
F
69-3/4
4-1/4
59-1/2
50-7/8
19-11/16
19
73
BTR-180
67-1/2
BTR-197
75
BTR-198
75
BTR-199
67-1/2
BTR-200(A)
72
BTR-250*(A)
72
BTR-251*(A)
75
BTR-275*(A)
72
BTR-305 (A)
75
BTR-365 (A) MODEL
79-1/2
BTR-400 (A)BTR-500
75-1/2
BTR-500 (A)
81-1/2
4-1/4
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
17-1/2
66-1/2
62
70
70
62
65-1/8
65-1/8
65-3/4
65-1/8
65-3/4
70-1/4
67-1/2
77-1/4
57-7/8
53-5/8
61-5/8
61-5/8
53-5/8
55-7/8
55-7/8
57-1/4
55-7/8
57-1/4
62-1/2
58-1/4
67-1/2
19-11/16
20-1/2
20-1/2
20-1/2
20-1/2
19-3/4
19-3/4
20
19-3/4
20
22-1/2
26-3/4
27
19
21
21
21
21
23
23
N/A
23
N/A
23
23
21
BTR-120*
BTR-154
OUTLET
C
H
D
INLET
J
E
B
A
G
1˝ CLEARANCE
GAS CONNECTION
MODEL
BTR-120-400
TOP
INLET
TOP
OUTLET
Model
Number
F
Master-Fit BTR 500
G
H
I
J
Standard
ASME
BTR-120*
1/2
51-7/8
6
27-3/4
400
-
BTR-154
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
3/4
1
59
54-5/8
62-5/8
61-1/2
54-5/8
56-3/8
56-3/8
58-3/4
56-3/8
58-3/4
63
59
67-1/2
6
6
6
6
6
8
8
8
8
8
8
8
8
27-3/4
27-3/4
27-3/4
27-3/4
27-3/4
30-1/4
30-1/4
27-3/4
30-1/4
27-3/4
27-3/4
30-1/4
27-3/4
470
470
603
603
470
630
630
750
630
750
725
760
812
725
725
862
725
862
833
874
857
BTR-180
INDUCED DRAFT MOTOR
BTR-197
I
BTR-198
BTR-199
BTR-200(A)
BTR-250*(A)
BTR-251*(A)
BTR-275*(A)
A
BTR-305 (A)
BTR-365 (A)
BTR-400 (A)
BTR-500 (A)
MODEL
R-120-400
78
MODEL
BTR-500
Approx. Shipping
Weight (lbs)
Dimensions in Inches
Specify when ordering propane (LP) gas.
*Model BTR 120 is shipped with 6” x 5” flue outlet adapter. Models BTR 250, 251 and
275 are shipped with a 8” x 6” flue outlet adapter.
Standard models certified from sea level to 2,000 ft. elevation. Order SMR S54 for
elevations up to 8,000 ft.
BTR-500 model features induced draft design and no damper.
79
COMMERCIAL GAS
MASTER-FIT® BTR BOOSTER
THE ELIMINATOR™ Self-Cleaning
System
1-1/2" NPI
OUTLET
1" NPI RELIEF
VALVE OPENING
H
15.2cm
• Designed to significantly reduce or eliminate
buildup of lime, sand and other sediment inside
the tank
• Reduced sediment buildup helps Master-Fit water
heaters maintain their rated energy efficiency and
reduce water heating costs
• Self-cleaning system also helps prolong tank life
Built-in Induced Draft Blower
• Produces power-induced draft of makeup air prior
to burner ignition
• Provides more efficient control of heat through
the flue collector
• No draft hood or barometric damper required
A
B
D
C
E
G
F
Rated as a Category 1 Appliance
• Can be commonly vented with other Category 1
appliances, using standard metal type “B” vent
Three-Year Limited Warranty
• For complete warranty information go to
hotwater.com
1.5
3.8cm
1-1/2" NPI
INLET
Model
Number
CLEARANCE
Gallon Capacity
BTU Input Per
Hour
Recovery Capacity
GPH @ 100°F Rise
BTR-151
32
150,000
145
BTR-201
32
199,900
194
Dimensions in Inches
Model
Number
BTR-151*
& BTR-201
A
B
C
D
E
F
G
45
40 27-3/4 32-1/4 15-3/4 5 6-1/2
H
6
Approx.
Shipping
Weight (lbs)
STD/ASME
440/460
Specify when ordering propane (LP) gas.
A 6” x 8” vent reducer is provided with each unit. Certified for 6” or 8” venting. See local
codes.
*Booster models are induced draft with no damper. Height is to the top of the blower motor.
Electrical characteristics- 120V-60 Hz A.C., 5.0A.
“A” after the model numbder designates ASME construction.
Leg Kits for UL Sanitation to meet NSF-5. Part # 9003425205
Uses standard metal single wall or double wall type B vent.
80
81
COMMERCIAL GAS
MASTER-FIT® ULTRA-LOW NOx
80% Thermal Efficiency means Lower
Operating Costs
Fan Assisted Combustion
• The blower is built into the low NOx burner
assembly
• Complies with California SCAQMD Rule 1146.2
and other Air Quality Management Districts with
similar NOx emission requirements of 14 ng/J or
20 ppm
Air-Flapper
• A stainless steel air flapper is used inside the
premix system to replace externally mounted flue
damper to minimize the standby heat loss and to
minimize the overall heater height
Metal Venting
• Rated Category I Appliance. Uses standard double
wall type “B” vent.
• Can be commonly vented with other Category I
appliances
• Vent connects directly to the vent connector outlet
• An excellent choice for retrofit and upgrade
installations
3-Year Limited Tank/1-Year Limited Parts
Warranty
Model Number
BTL-120
BTL-154
BTL-180
BTL-198
BTL-199
BTL-250
BTL-275
BTL-310
BTL-366
BTL-400
BTL-250A
BTL-275A
BTL-310A
BTL-366A
BTL-400A
Gallon
Capacity
Input BTU/HR
Recovery Capacity
GPH @ 100°F Rise
81
81
81
81
100
100
100
86
86
86
100
100
86
86
86
120,000
154,000
180,000
199,000
199,000
250,000
275,000
310,000
366,000
390,000
250,000
275,000
310,000
366,0000
390,000
115
148
173
191
191
240
264
298
352
375
240
264
298
352
375
Electrical characteristics—120V-60 Hz A. C., 5.0A.
(A) after model number designates ASME construction.
LEG KITS FOR UL SANITATION TO MEET NSF-5 (increases overall height by 4”).
BTL models not available in LP gas.
BTL models for sale in California only.
• For complete warranty information, consult written
warranty or go to hotwater.com.
Line drawings and dimensions on the following page.
82
83
COMMERCIAL GAS
MASTER-FIT® BTL ULTRA-LOW NOx
(CONTINUED)
ROUGH
IN DIMENSIONS: MASTER-FIT BTL 199 ULN
BTL-120, 154, 180,
198
K
Letter
F
BTL-199, 250(A),
275(A)
BTL-310(A), 366(A),
400(A)
Dimensions in Inches
TOP OUTLET
1 1/2 NPT
63-3/4
37
65
52-3/4
20-3/4
21
A
TOP INLET
1 1/2 NPT
B
C
AC
D
B
H
DH
LE
F
71-3/4
37
73
60-3/4
20-1/2
21
3/4 NPT
61
6
27-3/4
1-1/2 NPT
1-1/2 NPT
G
53
6
27-3/4
H
I
E
J
TOP VIEW
K
DIMENSIONS: MASTER-FIT BTL 199
ROUGH
ULN IN DIMENSIONS: MASTER-FIT BTL 199 ULN
BACK VIEW
I
F
F
OP OUTLET
1 1/2 NPT
TOP INLET
1 1/2 NPT
ASME
TOP OUTLET
1 1/2 NPT
TOP INLET
1 1/2 NPT
G
L
B
61
6
27-3/4
BTL-120, 154,
180, 198
BTL-199, 250(A),
275(A)
BTL-310(A), 366(A),
400(A)
650
N/A
750
800
810
860
K
Electrical characteristics—120V-60 Hz A. C., 5.0A.
(A) after model number designates ASME construction.
LEG KITS FOR UL SANITATION TO MEET NSF-5 (increases overall height by 4”).
BTL models not available in LP gas.
BTL models for sale in California only.
L
E
TOP VIEW
J
FRONT VIEW
84
H
DH
Approx.
Shipping
Weight
(lbs)
Standard
K
AC
B
L
71-3/4
37
73
60-3/4
20-1/2
21
TOP VIEW
BACK VIEW
BACK VIEW
85
T&P
VALVE
COMMERCIAL GAS
CONSERVATIONIST® BT
E
*TEMPERATURE
AND PRESSURE
RELIEF VALVE
C
COLD
HOT
H
G
Glasslined Tank
J
DRAIN
VALVE
• Maximizes tank life.
B
DRAIN VALVE
ANODE ROD
L
GAS INLET
• Fully Automatic Controls with Safety Shutoff
A
• Accurate, dependable control system requires no
electric connections. Fixed automatic gas shutoff
device for added safety. Not recommended for C
L
180°F sanitizing.
C
Heavy Gauge Steel Jacket
*INSTALL IN
ACCORDANCE
WITH LOCAL
CODES.
F
K
K
HOT WATER OUTLET
L
D
COLD WATER INLET
T&P
VALVE
• Finished with baked enamel over bonderized
M
undercoat.
Foam Insulation
*TEMPERATU
AND PRESSU
RELIEF VALV
• Saves fuel, helps reduce standby heat loss.
• Low NOx
C
Complies with Texas and other Districts
Requirements for NOx Emissions Less
than 40 ng/j
G
J
DRAIN VALV
A
• Completely factory-assembled. Only gas, water and
vent connections need be made. All connections
are located in front and top of heaters for ease of
installation and service.
CL
CL
3-Year Limited Tank / 1-Year Limited
Parts Warranty
D
M
• For complete warranty information, consult written
warranty or go to hotwater.com.
Gallon
Capacity
Input Rating
BTU/HR
Recovery Capacity
GPH @ 100°F Rise
Approx.
Shipping
Weight (lbs)
BT-100
74
98
75,100
75,100
73
73
275
350
Model
Number
A
B
C
D
E
F
61-1/8
68-5/8
58-1/2
66-1/2
26-1/2
27-3/4
15-3/16
15-3/16
16
16
4
4
G
H
J
K
L
M
14-1/2
15-3/4
29-11/16
30-15/16
54-1/4
54-1/4
1
1
1/2
1/2
11-15/16
11-15/16
Model
Number
BT-80
BT-80
BT-100
Model
Number
BT-80
BT-100
86
B
DRAIN
VALVE
Easy-to-Install
Dimensions in Inches
Dimensions in Inches
NSF leg kit 9006645005.
Specify when ordering (LP) gas.
87
COMMERCIAL GAS
INDUCED DRAFT LOW NOx BTN
POWER VENT
ROUGH-IN DIMENSIONS
SIDE VIEW OF BTN
Models 120-400
TOP VIEW OF BTN
Induced Draft Built-in Blower
• The blower is built into the top cover, factory
mounted and wired. Ideal for installations where
negative pressure is present in the building.
• Blower proves draft prior to ignition.
• No draft hood or barometric damper required.
Rated Category I Appliance.
• Uses standard metal single wall or double wall
type “B” vent. Can be commonly vented with other
Category I appliances. Vent connects directly to
the blower outlet. Perfect choice for retrofit and
upgrade installations.
Water Connections
• For ease of installation, all BTNs feature water
connections on the top, front, and rear.
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information consult written
warranty or go to hotwater.com.
Model
Number
BTN-120+
BTN-154
BTN-180
BTN-199
BTN-200 (A)
BTN-250 (A)
BTN-275 (A)
BTN-310 (A)
BTN-366 (A)
BTN-400 (A)
88
Gallon
Capacity
71
81
100
100
100
100
100
85
85
85
Recovery
Capacity
GPH @ 100°F
Rise
Input BTU/HR
Natural Gas
115
148
173
191
191
240
264
297
351
374
120,000
154,000
180,000
199,000
199,000
250,000
275,000
310,000
366,000
390,000
Approx. Shipping
Weight (lbs)
520
550
550
550
660
660
660
720
830
830
Dimensions in Inches
Model
Number
A
B
C
D
E
BTN-120+
63
4-1/4
59-1/2
50-7/8
19-5/8
BTN-154
TOP VIEW OF BTN
68
4-1/2
62
53-5/8
20-1/2
BTN-180
72
4-1/2
70
61-5/8
20-1/2
BTN-199
72
4-1/2
70
61-5/8
20-1/2
BTN-200 (A)
72
4-1/2
70
61-5/8
20-1/2
BTN-250 (A)
72
4-1/2
70
61-5/8
20-1/2
BTN-275 (A)
72
4-1/2
70
61-5/8
20-1/2
BTN-310 (A)
73
4-1/2
72
62-1/2
22-1/2
BTN-366 (A)
73
4-1/2
72
62-1/2
22-1/2
BTN-400 (A)
73
4-1/2
72
62-1/2
22-1/2
Model
Number
F
G
H
I
J
BTN-120+
19
3/4
51-7/8
6
27-3/4
BTN-154
21
3/4
54-5/8
6
27-3/4
BTN-180
21
3/4
61
6
27-3/4
BTN-199
21
3/4
61
6
27-3/4
BTN-200 (A)
21
3/4
61
6
27-3/4
BTN-250 (A)
21
3/4
61
6
27-3/4
BTN-275 (A)
21
3/4
61
6
27-3/4
BTN-310 (A)
21
3/4
63
6
27-3/4
BTN-366 (A)
21
1
63
6
27-3/4
BTN-400 (A)
21
1
63
6
27-3/4
Dimensions in Inches
Electrical characteristics-120V-60 Hz A.C., 5.0A.
“A” after model number designates ASME construction.
Leg Kits for UL Sanitation meet NSF-5.
Not available in propane (LP) gas.
+BTN-120 is approved for 5” vent using a 6” x 5” reducer.
Leg Kit for BTN-120 through 400 Part No. 9003425205.
Standard models certified from sea level to 2,000 ft. elevations.
Order SMR S54 for elevations up to 8,000 ft.
89
COMMERCIAL GAS
CONSERVATIONIST® POWER VENT
Approval Rating and Certification
• All models comply with ANSI Z21.10.3/CSA 4.3 and
ASHRAE/IES 90.1-2004
• Meets Texas and other low NOx areas requiring
40 ng/J
ANODE
D
• All models are approved for use in combined
appliance applications.
COLD
HOT
CFC Free Foam Insulation
• Minimize radiant heat loss
Dip Tube
• Carries inlet water deep into the tank
Hot Surface Ignition
• Has a solid state ignition surface that does not
flutter or blow out
• Provides increased reliability and efficiency over
spark ignition systems. Eliminates the pilot and saves
energy
User-Friendly
• State-of-art electronic gas control provides more
precise temperature control.
Ø
• LED control light displays operation status and
diagnostics
3-Year Limited Tank/1-Year Limited Parts
Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com.
Model Number
Approx. Gallon
Capacity
Btuh Input
Approx. Shipping
Weight
BTF-80
75
76,000
277 lbs
Model Number
BTF-80
Model Number
BTF-80
90
Dimensions in inches
A
B
C
D
70-5/8
61-1/4
26
33-1/8
Dimensions in inches
E
F
G
H
11
13-1/4
53
15-1/4
Recovery capacity based on 81% thermal efficiency.
Available in LP (Propane) gas.
Can be installed up to 10,100 feet without alteration.
91
COMMERCIAL GAS
CONSERVATIONIST® POWER
DIRECT VENT
DynaClean™ Diffuser Dip Tube
• Helps reduce lime and sediment buildup and
maximizes hot water output. Made from long-lasting
PEX cross-linked polymer
Blue Diamond® Glass Coating
• Provides superior corrosion
resistance compared to
C
the industry-standard glasslining.
D
A
Hot Surface Ignition
B
• Has a solid state ignition surface that does not
flutter or blow out
G
• Provides increased reliability and efficiency over
spark ignition systems. Eliminates the pilot and saves
energy.
Standards
• Design-certified by CSA International, according
to ANSI Z21.10.3-CSA 4.3 standards governing
F
storage-type water heaters.
E
H
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1.
3-Year Limited Tank/1-Year Limited Parts
Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com
C
A
B
®
G
F
Model
Number
E
Approx. Gallon Capacity
Btuh Input
Approx. Shipping
Weight (lbs)
75
76,000
277
BPD-80
Model
Number
BPD-80
92
H
Dimensions in Inches
A
B
70-5/8 61-1/4
C
D
E
F
G
H
26
33-1/8
11
13-1/4
53
15-1/4
Specify when ordering propane (LP) gas.
Can be installed up to 10,100 feet without alteration.
Recovery capacity based on 81% thermal efficiency.
93
K
HOT WATER
OUTLET
COMMERCIAL GAS
F
®
CONSERVATIONIST ULTRA-LOW NOx
K
COLD WATER
INLET
TOP VIEW
H
J
TEMPERATURE
AND PRESSURE
RELIEF VALVE
DRAIN
Code Compliance
VALVE
• The Ultra-Low NOx atmospheric vent commercial D
gas water heater which meets the thermal
efficiency and standby loss requirements of the
U.S. Department of Energy and Current Edition
ASHRAE/IESNA 90.1. A
Fully Automatic Controls with Safety
Shutoff
C
COLD
HOT
G
B
DRAIN VALVE
K
HOT WATER
OUTLET
L
GAS INLET
• Accurate, dependable control system requires no
E
electric connections. Fixed automatic
gas shutoff
M
device for added safety. Not recommended
for
180˚ F sanitizing.
K
COLD WATER
INLET
F
J
Heavy Gauge Steel Jacket
FRONT VIEW
• Finished with baked enamel over bonderized
undercoat
DRAIN
VALVE
Foam Insulation
D
• Saves fuel, helps reduce standby heat loss.
Ultra-Low NOx Emissions
B
• Complies with SCAQMD Rule 1146.2 and other
Air Quality Management Districts with similar
requirements of 14 ng/J or 20 ppm.
A
Easy-to-Install
• Completely factory-assembled. Only gas, water
and vent connections need to be made. All
connections are located in front and top of
heaters for ease-of-installation and service.
E
M
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information, consult
written warranty or go to hotwater.com
FRONT VIEW
Gallon
Capacity
Input BTU/hr
Recovery Capacity
GPH @ 100°F Rise
Approx.
Shipping
Weight (lbs)
BL-80 **
74
75,100
73
285
BL-100*
98
75,100
74
350
Model
Number
Dimensions in Inches
Model
Number
BL-80 **
BL-100*
A
B
C
D
E
62-1/16
70-1/2
58
66-1/2
29-1/2
30-15/16
25-1/4
27-3/4
15-7/8
15-3/16
Dimensions in Inches
Model
Number
BL-80 **
BL-100*
94
F
G
H
J
K
L
M
4
4
15-1/4
15-3/4
16
16
2
1-1/4
1
1-1/4
1/2
1/2
12-1/2
11-15/16
Natural gas only.
*Recovery rating based on 81% thermal efficiency
**Recovery rating based on 80% thermal efficiency
95
COMMERCIAL GAS
POWER BURNER LIGHT DUTY
D
19.00
Power Gas Burner
H
• Electronic flame safeguard control with direct
spark ignition
• Redundant gas valves for added safety
• Power gas burner requires 120V, 60Hz service
ROUGH IN DIMENSIONS - Models BTP-139(A) Thru BTP-370(A)
64.93"
• Non-forced-draft burner; negative draft required
in vent piping
BAROMETRIC DRAFT
CONTROL ASSEMBLY
Fully Automatic Controls with Safety
Shutoff
• High temperature limit control (manual reset)
INLET &
DIP TUBE
OUTLET
• Dual thermostats for accurate temperature control
Glass Coating
HI T’STAT
OUTLET
• Exclusive process provides superior protection
against corrosion
T&P
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com
G
J
A
LO’ TSTAT
INLET
B
CLEANOUT
34.75"
INSPECTION
POWER BURNER
ASSEMBLY
C
24.75"
E
Model
Number
BTU Input Per
Hour
Tank
Size
GPH
BTP-139(A)
140,000
199,000
270,000
370,000
81
81
81
81
GPH
GPH
GPH
GPH
BTP-199(A)
BTP-270(A)
BTP-370(A)
Recovery
Gallons Per Hour
Temperature Rise
100°
Maximum
Amperes
120V, 60
Hz, 1
136
193
262
359
5
5
5
5
Model
Number
BTP-139(A)
BTP-199(A)
BTP-270(A)
BTP-370(A)
Model
Number
BTP-139(A)
BTP-199(A)
BTP-270(A)
BTP-370(A)
96
Dimensions in Inches
A
B
C
D
E
74-3/4
74-3/4
74-3/4
74-3/4
65
65
65
65
26-3/4
26-3/4
26-3/4
26-3/4
6
6
6
6
21-3/8
21-3/8
21-3/8
21-3/8
Dimensions in Inches
Approx. Shipping Weight
G
H
J
Standard
ASME
27-3/4
27-3/4
27-3/4
27-3/4
38
38
38
38
85-1/4
85-1/4
85-1/4
85-1/4
556 lbs
545 lbs
547 lbs
547 lbs
658 lbs
635 lbs
632 lbs
632 lbs
97
COMMERCIAL GAS
LOW NOx POWER BURNER
Venting Options
1-1/2" INLET
& DIP TUBE
1-1/2"
OUTLET
• BTP models designed for conventional
atmospheric vertical venting. Barometric draft
regulating damper provided. Order Vent Kit Part
#9500007350.
I
• BTPV models designed for horizontal atmospheric
sidewall venting or direct venting.
D
1-1/2" NPT OUTLET
OPENING
(FRONT & BACK)
• For sidewall venting order Vent Kit Part
#950007229.
1" NPT T&P
VALVE OPENING
• For direct venting order Vent Kit Part
#9910001005.
Low NOx Power Gas Burner (Natural
Gas Only)
• Pre-mix design with internal Flue Gas Recirculation
(FGR)
• Safety features include internal blocked flue sensor,
separate pilot system, internal thermal cutoff and
anti-flashback barrier.
G
1-1/2" NPT
INLET
OPENING
(FRONT &
BACK)
E
I
H
A
B
FLUE REDUCER
SHIPPED W/VENT HOOD
CLEANOUT
OPENING
1-1/2" NPT
OUTLET OPENING
(FRONT & BACK)
1" NPT T&P
VALVE OPENING
C
F
Fully Automatic Controls
1-1/2" NPT
INLET
OPENING
(FRONT &
BACK)
• Including safety shut-off, high-temperature limit
control
H
A
• Dual thermostat, adjust from 120˚F to 180˚F
B
3-Year Limited Tank and 1-Year Limited
Parts Warranty
CLEANOUT
OPENING
Model Number
BTP(V)-540A
BTP(V)-650A
BTP(V)-740A
Gallon Input/BTU/HR
Capacity Natural Gas
85
85
85
540,000
650,000
740,000
Recovery Capacity
GPH @ 100°F Rise
523
630
718
Approx.
Shipping
Weight (lbs)
950
950
950
Not available in propane (LP).
Vent Kit included in unit price.
Authorizes start-up service included- required to activate warranty. Consult local factory
representative (Continental U.S. only)
C
F
• For complete warranty information, consult written
warranty or go to hotwater.com
Model Number
BTP(V)-540A
BTP(V)-650A
BTP(V)-740A
Model Number
BTP(V)-540A
BTP(V)-650A
BTP(V)-740A
Dimensions in Inches
A
B
C
D
E
80-3/4
80-3/4
80-3/4
73
73
73
32-1/4
32-1/4
32-1/4
9
9
9
26-1/2
26-1/2
26-1/2
Dimensions in Inches
F
G
H
I
26-1/2
26-1/2
26-1/2
93
93
93
29-1/2
29-1/2
29-1/2
48-1/2
48-1/2
48-1/2
Not available in propane (LP).
Vent Kit included in unit price.
Authorizes start-up service included- required to activate warranty. Consult local factory
representative (Continental U.S. only)
98
99
COMMERCIAL GAS
CONSERVATIONIST® HIGH VOLUME
POWER BURNER
Power Gas Burner
• Suitable for natural or propane gas
• Electronic flame safeguard control with
intermittent spark ignition
Model Number
• Main and pilot automatic gas valves with gas
pressure regulators
BTP-150-140
• Diaphragm air switch for proof of blower operation
BTP-150-255
• Flame inspection port
BTP-150-270
BTP-150-199
Fully Automatic Controls with Safety
Shutoff
BTP-150-400
• High-temperature limit control (manual reset)
BTP-150-720
• CSA certified and ASME rated T&P relief valve
BTP-200-300
• Hinged-door control compartment for accurate
temperature control
BTP-200-600
• Standard control is for 120o-180oF water service
BTP-200-1000
• Factory-installed low-water cutoff
BTP-200-1250
Blue Diamond® Glass Coating
• Provides superior corrosion resistance compared to
the industry-standard glasslining.
Codes and Standards
• Design-certified by UL (Underwriters Laboratories),
according to ANSI Z21. 10.3-4.3 CSA Standards
• Meets the thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA 90.1
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• -For complete warranty information, consult written
warranty or go to hotwater.com
BTP-150-540
BTP-200-800
BTP-200-1500
BTP-300-300
BTP-300-600
BTP-300-800
BTP-300-1000
BTP-300-1250
BTP-300-1500
BTP-400-600
BTP-400-800
BTP-400-1000
BTP-400-1250
BTP-400-1500
BTP-400-1750
BTP-400-2000
BTP-600-720
BTP-600-1000
BTP-600-1250
BTP-600-1500
BTP-600-1750
BTP-600-2000
BTP-600-2250
BTP-600-2500
Gallon
Capacity
Recovery Capacity
GPH @ 100°F Rise
Input BTU/
HR *Natural
Gas
Approx.
Shipping
Weight
(lbs)
163
163
163
163
151
151
145
221
221
221
221
210
201
300
300
411
411
411
411
411
411
411
411
411
404
397
594
594
594
594
594
594
585
575
136
193
247
262
387
524
698
291
582
776
970
1212
1454
291
582
776
970
1212
1454
582
776
970
1212
1455
1697
1939
698
970
1212
1454
1697
1939
2182
2424
140,000
199,000
255,000
270,000
400,000
540,000
720,000
300,000
600,000
800,000
1,000,000
1,250,000
1,500,000
300,000
600,000
800,000
1,000,000
1,250,000
1,500,000
600,000
800,000
1,000,000
1,250,000
1,500,000
1,750,000
2,000,000
720,000
1,000,000
1,250,000
1,500,000
1,750,000
2,000,000
2,250,000
2,500,000
1292
1292
1292
1397
1397
1505
1510
2098
2098
2103
2103
2467
2757
2150
2150
2308
2308
2584
2774
3207
3212
3212
3212
3402
3528
3669
3667
3667
3667
3837
3837
3837
4477
4619
†Models with an (N) are available in low NOx (include the “N” in the model number when
ordering)
Specify when ordering propane (LP) gas.
Authorized start-up service included-required to activate warranty. Consult local factory
representative (Continental U.S. Only).
Line drawings and dimensions on the following page.
100
101
COMMERCIAL GAS
CONSERVATIONIST® HIGH VOLUME
POWER BURNER (CONTINUED)
Model Number
Dimensions in Inches
A
B
C
G
H
J
BTP-150-140
82-1/4 13-1/2
1/2
29-1/4 1-1/4 36-1/2
D
E
F
5
47
73-1/2
BTP-150-199
82-1/4 13-1/2
1/2
29-1/4 1-1/4 36-1/2
6
47
73-1/2
BTP-150-255
82-1/4 13-1/2
1/2
29-1/4 1-1/4 36-1/2
6
47
73-1/2
BTP-150-270
82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
6
57-1/2 73-1/2
BTP-150-400
82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
7
57-1/2 73-1/2
BTP-150-540
82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
8
57-1/2 73-1/2
BTP-150-720
82-1/4 13-1/2 1-1/4 29-1/4 1-1/4 36-1/2 10
57-1/2 73-1/2
BTP-200-300
84-1/2 17-1/2
1
34-3/4 1-1/2 44-3/4
6
66-1/2 74-3/4
BTP-200-600
84-1/2 17-1/2
1
34-3/4 1-1/2 44-3/4
8
66-1/2 74-3/4
BTP-200-800
84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10
66-1/2 74-3/4
BTP-200-1000
84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10
66-1/2 74-3/4
BTP-200-1250
84-3/4 13-1/2 1-1/4 29-1/2 1-1/2 44-3/4 12
66-1/2
75
BTP-200-1500
84-3/4 13-1/2 1-1/2 29-1/2 1-1/2 44-3/4 12
81-1/2
75
BTP-300-300
92
14
1
29-1/4 1-1/2 44-3/4
6
66-1/2 82-1/2
BTP-300-600
92
14
BTP-300-800
92
14
1
29-1/4 1-1/2 44-3/4
8
66-1/2 81-1/2
1-1/4 29-1/4 1-1/2 44-3/4 10
BTP-300-1000
92
14
1-1/4 29-1/4 1-1/2 44-3/4 10
66-1/2 81-1/2
66-1/2 81-1/2
BTP-300-1250
92
14
1-1/4 29-1/4 1-1/2 44-3/4 12
66-1/2 81-1/2
BTP-300-1500
92
14
1-1/2 29-1/4 1-1/2 44-3/4 12
81-1/2 81-1/2
BTP-400-600
89
17-1/2
33-1/4
2
55
8
76-1/2 78-3/4
BTP-400-800
89
17-1/2 1-1/4 33-1/4
2
55
10
76-1/2 78-3/4
BTP-400-1000
89
17-1/2 1-1/4 33-1/4
2
55
10
76-1/2 78-3/4
BTP-400-1250
89
17-1/2 1-1/4 33-1/4
2
55
12
76-1/2 78-3/4
BTP-400-1500
89
17-1/2 1-1/2 33-1/4
2
55
12
91-1/2 78-3/4
BTP-400-1750
89
17-1/2
2
33-1/4
2
55
14
91-1/2 78-3/4
96-1/4 17-1/2
2
1
33-1/4
2
55
14
91-1/2 86-1/2
BTP-600-720
114
17-1/2 1-1/4 33-1/4
2
55
10
76-1/2
105
BTP-600-1000
114
17-1/2 1-1/4 33-1/4
2
55
10
76-1/2
105
BTP-600-1250
114
17-1/2 1-1/4 33-1/4
2
55
12
76-1/2
105
BTP-600-1500
114
17-1/2 1-1/2 33-1/4
2
55
12
91-1/2
105
BTP-600-1750
114
17-1/2
2
33-1/4
2
55
14
91-1/2
105
BTP-600-2000
114
17-1/2
2
33-1/4
2
55
14
91-1/2
105
BTP-600-2250
114
17-1/2
2
33-1/4
2
55
16
91-1/2
105
BTP-600-2500
114
17-1/2
2
33-1/4
2
55
14
91-1/2
105
BTP-400-2000
†Models with an (N) are available in low NOx (include the “N” in the model number when
ordering)
Specify when ordering propane (LP) gas.
Authorized start-up service included-required to activate warranty. Consult local factory
representative (Continental U.S. Only).
102
103
COMMERCIAL GAS
CONSERVATIONIST® DURACLAD
OIL-FIRED TANK-TYPE
Efficient Combustion Chamber
• Precast, high temperature combustion
chamber made of alumina silica ceramic fiber.
Engineered for maximum insulation and heat
reflection. Unique design assures more complete
combustion by stabilizing flame pattern.
Interrupted Ignition
• Reduces electrical consumption
Two Hand-hole Cleanouts
• Allows easy cleaning on standard models COF385 and larger and ASME models
Easy-to-Install Burner
• Three bolt mounting of burner assures easy
installations.
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information consult
written warranty or go to hotwater.com
Dimensions in Inches
Model Number
A
B
C
D
E
F
COF-199
74-1/2
36-3/4
27-3/4
2
3/4 NPT
8
COF-245
74-1/2
36-3/4
27-3/4
2
3/4 NPT
8
COF-315 (A)
74-1/2
73-3/4
73-3/4
73-3/4
36-3/4
36-3/4
36-3/4
36-3/4
27-3/4
27-3/4
27-3/4
27-3/4
2
2
2
2
3/4 NPT
3/4 NPT
3/4 NPT
3/4 NPT
8
8
8
8
G
H
J
K
L
COF-199
26-5/8
74-1/2
1-1/2 NPT
1-1/2 NPT
22-3/4
COF-245
26-5/8
74-1/2
1-1/2 NPT
1-1/2 NPT
22-3/4
26-5/8
COF-385 (A) 24-3/4
COF-455 (A) 24-3/4
COF-700 (A) 30-3/16
74-1/2
73-3/4
73-3/4
79-3/16
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
1-1/2 NPT
22-3/4
23-7/16
23-7/16
28-7/8
COF-385 (A)
COF-455 (A)
COF-700 (A)
Available on
COF-315 and higher
Model
Number
COF-199
COF-245
COF-315 (A)
COF-385 (A)
COF-455 (A)
COF-700 (A)
104
Model
Number
Recovery
Approx. Shipping
Gallon Input BTU/ Capacity Motor
Weight (lbs)
Capacity
HR
GPH @ 100°F HP
Standard
ASME
Rise
86
86
84
75
75
69
199,000
245,000
315,000
385,000
455,000
700,000
191
235
302
369
436
671
1/8
1/8
1/8
1/8
1/8
1/8
553
554
554
624
700
739
N/A
N/A
657
742
747
822
COF-315 (A)
Dimensions in Inches
*Based on No. 2 fuel oil. All models have 1/8 HP motor.
Add “S” to the end of the model number for standard (COF-199S) and “A” to the end of
the model number for ASME (COF-700A) tanks..
105
COMMERCIAL GAS
CUSTOM HEAVY-DUTY LARGE
VOLUME OIL-FIRED
Model Number
Fully Automatic Controls with Safety
Shutoff
• High temperature limit control (manual reset).
CSA Certified and ASME rated temperature and
pressure relief valve.
163
140,000
136
163
199,000
193
COF-150-255
163
163
150
151
151
145
221
221
221
201
201
201
300
300
300
300
300
300
411
411
411
411
397
397
397
594
594
594
594
594
594
575
575
255,000
270,000
350,000
400,000
540,000
720,000
300,000
600,000
800,000
1,000,000
1,250,000
1,500,000
300,000
600,000
800,000
1,000,000
1,250,000
1,500,000
600,000
800,000
1,000,000
1,250,000
1,500,000
1,750,000
2,000,000
720,000
1,000,000
1,250,000
1,500,000
1,750,000
2,000,000
2,250,000
2,500,000
247
262
339
387
524
698
291
582
776
970
1212
1455
291
582
776
970
1212
1455
582
776
970
1212
1455
1697
1939
698
970
1212
1455
1697
1939
2182
2424
COF-150-270
• Two thermostats, upper and lower, for accurate
temperature control.
COF/COBT-150-540
COF/COBT-150-400
COF/COBT-150-720
• Heavy gauge steel jacket with baked powder coat
finish.
COF/COBT-200-300**
• Insulated with high-density foam insulation that
meets or exceed all required standards.
COF/COBT-200-800
• Meets or exceeds the thermal efficiency and/or
standby loss requirements of the U.S.
COF/COBT-200-1250
• Department of Energy and current edition ASHRAE/
IESNA 90.1.
COF/COBT-300-300**
• -For complete warranty information consult written
warranty or go to hotwater.com
Recovery Capacity
GPH @ 100°F Rise
COF-150-140
COBT-150-350
3-Year Limited Tank and 1-Year Limited
Parts Warranty
Input Rating
BTU/HR
COF-150-199
• Hinged door control compartment with key lock for
ease of access.
Jacket and Insulation
Gallon
Capacity
COF/COBT-200-600
COF/COBT-200-1000
COF/COBT-200-1500
COF/COBT-300-600
COF/COBT-300-800
COF/COBT-300-1000
COF/COBT-300-1250
COF/COBT-300-1500
COF/COBT-400-600
COF/COBT-400-800
COF/COBT-400-1000
COF/COBT-400-1250
COF/COBT-400-1500
COF/COBT-400-1750
COF/COBT-400-2000
COF/COBT-600-720
COF/COBT-600-1000
COF/COBT-600-1250
COF/COBT-600-1500
COF/COBT-600-1750
COF/COBT-600-2000
COF/COBT-600-2250
COF/COBT-600-2500
*COBT models are 350,000 BTU Natural Gas.
Authorized start-up service included-required to activate warranty.
Consult local factory representative. (Continental U. S. Only).
Specify when ordering propane (LP) gas.
Line drawings and dimensions on the following page.
106
107
COMMERCIAL GAS
CUSTOM HEAVY-DUTY LARGE
VOLUME OIL-FIRED (CONTINUED)
Model Number
Dimensions in Inches
A
B
C
G
H
J
COF-150-140
82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2
D
E
F
5
47
73-1/2
COF-150-199
82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2
6
47
73-1/2
COF-150-255
82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2
6
47
73-1/2
COF-150-270
82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
6
57-1/2 73-1/2
COBT-150-350
82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
7
57-1/2 73-1/2
COF/COBT-150-400 82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
7
57-1/2 73-1/2
COF/COBT-150-540 82-1/4 13-1/2
1
29-1/4 1-1/4 36-1/2
8
57-1/2 73-1/2
COF/COBT-150-720 82-1/4 13-1/2 1-1/4 29-1/4 1-1/4 36-1/2 10 57-1/2 73-1/2
COF/COBT-200-300 84-1/2 17-1/2
1
34-3/4 1-1/2 44-3/4
6
66-1/2 74-3/4
COF/COBT-200-600 84-1/2 17-1/2
1
34-3/4 1-1/2 44-3/4
8
66-1/2 74-3/4
COF/COBT-200-800 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4
COF/COBT-200-1000 84-1/2 17-1/2 1-1/4 34-3/4 1-1/2 44-3/4 10 66-1/2 74-3/4
COF/COBT-200-1250 84-3/4 13-1/2 1-1/4 29-1/2 1-1/2 44-3/4 12 66-1/2
75
COF/COBT-200-1500 84-3/4 13-1/1 1-1/4 29-1/2 1-1/2 44-3/4 12 81-1/2
75
COF/COBT-300-300
92
14
COF/COBT-300-600
92
14
COF/COBT-300-800
92
14
1-1/4 29-1/4 1-1/2 44-3/4 10 66-1/2 81-1/2
COF/COBT-300-1000
92
14
1-1/4 29-1/4 1-1/2 44-3/4 10 66-1/2 81-1/2
COF/COBT-300-1250
92
14
1-1/4 29-1/4 1-1/2 44-3/4 12 66-1/2 81-1/2
COF/COBT-300-1500
92
14
1-1/4 29-1/4 1-1/2 44-3/4 12 81-1/2 81-1/2
COF/COBT-400-600
89
17-1/2
33-1/4
2
55
8
COF/COBT-400-800
89
17-1/2 1-1/4 33-1/4
2
55
10 76-1/2 78-3/4
COF/COBT-400-1000
89
17-1/2 1-1/4 33-1/4
2
55
10 76-1/2 78-3/4
COF/COBT-400-1250
89
17-1/2 1-1/4 33-1/4
2
55
12 76-1/2 78-3/4
COF/COBT-400-1500
89
17-1/2 1-1/4 33-1/4
2
55
12 91-1/2 78-3/4
COF/COBT-400-1750
89
17-1/2
2
33-1/4
2
55
14 91-1/2 78-3/4
COF/COBT-400-2000 96-1/4 17-1/2
2
33-1/4
2
55
14 91-1/2 86-1/2
114
17-1/2 1-1/4 33-1/4
2
55
10 76-1/2
108
COF/COBT-600-1000 114
17-1/2 1-1/4 33-1/4
2
55
10 76-1/2
105
COF/COBT-600-1250 114
17-1/2 1-1/4 33-1/4
2
55
12 76-1/2
105
COF/COBT-600-1500 114
17-1/2 1-1/2 33-1/4
2
55
12 91-1/2
105
COF/COBT-600-1750 114
17-1/2
2
33-1/4
2
55
14 91-1/2
105
COF/COBT-600-2000 114
17-1/2
2
33-1/4
2
55
14 91-1/2
105
COF/COBT-600-2250 114
17-1/2
2
33-1/4
2
55
16 91-1/2
105
COF/COBT-600-2500 114
17-1/2
2
33-1/4
2
55
16 91-1/2
105
COF/COBT-600-720
1
29-1/4 1-1/2 44-3/4
6
66-1/2 81-1/2
1
29-1/4 1-1/2 44-3/4
8
66-1/2 81-1/2
1
76-1/2 78-3/4
*COBT models are 350,000 BTU Natural Gas.
Authorized start-up service included-required to activate warranty.
Consult local factory representative. (Continental U. S. Only).
Specify when ordering propane (LP) gas.
108
109
COMMERCIAL GAS
TANKLESS NON-CONDENSING
INDOOR MODEL
13-3/4" (350mm)
10" (254mm)
4" (101 mm)
13-3/4" (350mm)
10" (254mm)
1-3/4"
(45mm)
1-3/4" (45mm)
4-3/8" (113mm)
1-3/4" (45mm)
Maximum Flow Rates up to 10.0 GPM
1-7/8" (47mm)
HOT 5-1/4" (133mm)
1-7/8" (47mm) 120V 1-3/8" (36mm)
COLD 3-1/4" (84mm) GAS 4-7/8" (124mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
• Includes a wall mount temperature remote
controller and advanced diagnostics to simplify
troubleshooting
1-5/8" (43mm)
20-1/4" (520mm)
• Air-Fuel Ratio (AFR) Sensor
21-3/8" (544mm)
Safety Features
20-1/4" (520mm)
• Easy-Link up to 4 units
21-3/8" (544mm)
ATI-510 & ATO-510 Can Be Used In Both
Residential and Commercial Applications
1-5/8" (43mm)
4-3/8" (113mm)
4-3/8" (113mm)
19-3/8" (493mm)
Low NOx Emissions
OUTDOOR MODEL
13-3/4" (350mm)
13-3/4" (350mm)
10" (254mm)10" (254mm)
7-7/8" (203mm)
7-7/8" (203mm)
1-3/4" (45mm)
1-3/4"
(45mm)
1-3/4" (45mm)
1-3/4" (45mm)
5" (128mm) 5" (128mm)
1-5/8" (43mm)
Factory-Installed Power Cord Included
For Indoor Models
1" (26mm)
COLD 2-7/8" (71mm)
1" (26mm)
120VAC 3-7/8" (99mm)
COLD 2-7/8" (71mm)
GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm)
HOT 6-1/2" (164mm)
GAS 5-1/4" (135mm)
9-1/2" (241mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
19-3/8" (493mm)
Indoor/Outdoor Models
COLD 3-1/4" (84mm)
19-3/8" (493mm)
20-1/4" (520mm)
21-3/8" (544mm)
19-3/8" (493mm)
1-3/8" (36mm)
20-1/4" (520mm)
• Primary heat exchanger of the ATI/ATO-510 is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperatures quicker and reducing
pressure drop across the heat exchanger
1-3/8" (36mm)
21-3/8" (544mm)
Copper Primary Heat Exchanger
4-3/8" (113mm)
4" (101 mm)
1-3/4" (45mm)
• Exhaust & Water Temperature Safety Control
• Overheat cut-off fuse
Internal Freeze Protection
Power Vent or Power Direct Vent Design
1" (26mm) 1" (26mm)
2-7/8" (71mm)
COLD 2-7/8"COLD
(71mm)
120VAC
3-7/8" (99mm)
120VAC 3-7/8"
(99mm)
GAS 5-1/4" (135mm)
GAS 5-1/4" (135mm)
1-3/8" (36mm)
120V 1-3/8" 120V
(36mm)
HOT 6-1/2" (164mm)
HOT 6-1/2" (164mm)
GAS 4-7/8" (124mm)
9-1/2" (241mm)
GAS 4-7/8" (124mm)
9-1/2" (241mm)
1-7/8" (47mm)
1-7/8" (47mm)
3-1/4" (84mm)
COLD 3-1/4"COLD
(84mm)
HOT 5-1/4" (133mm)
HOT 5-1/4" (133mm)
Warranty
510 Models
• 15-year limited warranty on heat exchanger in
residential applications.
• 10-year limited warranty on heat exchanger in
commercial applications.
ANSI Z21.10.3
CSA 4.3
• 5-year warranty on all parts.
Model
Number*
Type
Inlet Gas Pressure
Maximum
Minimum Maximum
BTU/H
in. W.C.
in.W.C.
Energy
Factor
(EF)
Hot/Cold
Gas
Connections Connection
Indoor Models
ATI-510-N
Natural 199,000
Model
Type
Number*
5.0
10.5
0.82
Sizing Chart
(Number of Showers)
3/4” NPT
3/4” NPT
Clearance (Inches)
Cold Climate**
Warm
Climate***
Top
2.5
3.5
12
Bottom Side Front Back
Indoor Models
ATI-510-N
110
Natural
12
2
4
*For propane models, change “N” to “P” in the model number (example:ATI-510-P)
For outdoor models change “I” to “O” in the model number (example: ATO-510-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
0.5
111
COMMERCIAL GAS
TANKLESS NON-CONDENSING
ULTRA-LOW NOx
INDOOR MODEL
13-3/4" (350mm)
10" (254mm)
1-3/4" (45mm)
4" (101 mm)
13-3/4" (350mm)
10" (254mm)
1-3/4"
(45mm)
4-3/8" (113mm)
4" (101 mm)
4-3/8" (113mm)
1-3/4" (45mm)
1-3/4" (45mm)
1-3/8" (36mm)
19-3/8" (493mm)
19-3/8" (493mm)
Maximum Flow Rates Up To 10.0 GPM
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
• Complies with SCAQMD 1146.2 NOx emission
requirements of 14 ng/J or 20 PPM.
1-5/8" (43mm)
1-3/8" (36mm)
Ultra-Low NOx Emissions
Copper Primary Heat Exchanger
HOT 5-1/4" (133mm)
1-7/8" (47mm) 120V 1-3/8" (36mm)
COLD 3-1/4" (84mm) GAS 4-7/8" (124mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
OUTDOOR MODEL
Safety Features
• Air-fuel ratio (AFR) Sensor.
4-3/8" (113mm)
7-7/8" (203mm)
1-3/4" (45mm)
5" (128mm)
4-3/8" (113mm)
1-7/8" (47mm)
COLD 3-1/4" (84mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
19-3/8" (493mm)
1-5/8" (43mm)
7-7/8" (203mm)
1-3/4" (45mm)
5" (128mm)
20-1/4" (520mm)
21-3/8" (544mm)
• Multi-Link Up to 20 Units.
20-1/4" (520mm)
• Easy-Link Up To 4 Units.
13-3/4" (350mm)
10" (254mm)
1-3/4" (45mm)
21-3/8" (544mm)
ATI-510U / ATO-510U Can be Used
in Both Residential and Commercial
Applications
13-3/4" (350mm)
10" (254mm)
1-3/4" (45mm)
19-3/8" (493mm)
Indoor/Outdoor Models
• Include a Wall Mount Temperature Remote
Controller and Advanced Diagnostics to Simplify
Troubleshooting.
1" (26mm)
COLD 2-7/8" (71mm)
1" (26mm)
120VAC 3-7/8" (99mm)
COLD 2-7/8" (71mm)
GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm)
HOT 6-1/2" (164mm)
GAS 5-1/4" (135mm)
9-1/2" (241mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
1-7/8" (47mm)
COLD 3-1/4" (84mm)
1-5/8" (43mm)
• Primary heat exchange of the ATI/ATO-510U is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperatures quicker and reducing
pressure drop across the heat exchanger indoor
and outdoor models available.
1" (26mm)
COLD 2-7/8" (71mm)
120VAC 3-7/8" (99mm)
GAS 5-1/4" (135mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
1" (26mm)
COLD 2-7/8" (71mm)
120VAC 3-7/8" (99mm)
GAS 5-1/4" (135mm)
HOT 6-1/2" (164mm)
9-1/2" (241mm)
• Exhaust & Water Temperature Safety Control.
• Overheat cut-off fuse.
1-7/8" (47mm)
COLD 3-1/4" (84mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
Internal Freeze Protection
Power Vent or Power Direct Vent Design
Warranty
• 15-year limited warranty on heat exchanger in
residential applications.
• 5-year limited warranty on heat exchanger in
commercial applications.
ANSI Z21.10.3
CSA 4.3
Model
Number*
Type
Inlet Gas Pressure
Maximum
Minimum Maximum
BTU/hr
in. W.C.
in.W.C.
Energy
Hot/Cold
Gas
Factor
Connections Connection
(EF)
Indoor Models
ATI-510U-N Natural 199,000
• 5-year limited warranty on all parts.
Model
Number*
Type
5.0
10.5
Sizing Chart
(Number of Showers)
0.82
3/4” NPT
3/4” NPT
Clearance (Inches)
Cold
Climate**
Warm
Climate***
Top
Bottom
2.5
3.5
12
12
Side Front Back
Indoor Models
ATI-510U-N Natural
112
2
4
*For propane models, change “N” to “P” in the model number (example:ATI-510-P)
For outdoor models change “I” to “O” in the model number (example: ATO-510-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
0.5
113
COMMERCIAL GAS
TANKLESS CONDENSING
HIGH EFFICIENCY
Maximum Flow Rates up to 10.0 GPM
Indoor Models
• Include integrated temperature controls and
advanced diagnostics to simplify troubleshooting.
• Include factory-installed power cords
Outdoor Models
• Include a wall mount temperature remote
controller and advanced diagnostics to simplify
troubleshooting.
Common Vent Indoor Models up to 8
Units
22-1/2" (570 mm)
1/2 (13 mm)
GAS 5-1/8" (131 mm)
HOT 5-1/2" (140 mm)
Drain port 6" (152 mm)
COLD 6-3/4" (172 mm)
120 VAC 6-7/8" (174 mm)
Condens ate drain port
7-7/8" (199 mm)
COLD 5/8" (17 mm)
120 VAC 3" (77 mm)
GAS 5-3/4" (147 mm)
Condens ate drain port
7-1/2" (189 mm)
OUTDOOR MODEL
Condens ate drain port
7-1/2" (189 mm)
GAS 5-7/8" (147 mm)
120 VAC 3" (77 mm)
OUTDOOR MODEL
HOT 4-3/4" (120 mm)
17-5/8" (448 mm)
17-3/4" (450 mm)
7" (180 mm)
11-1/4" (285 mm)
4-1/2" (114 mm)
11" (281 mm)
6-1/4" (159 mm)
COLD 5/8" (17 mm)
10-3/4" (272 mm)
HOT 4-3/4" (120 mm)
120 VAC 6-1/4" (159 mm)
Drain port
6-3/4" (170 mm)
1/2" (13 mm)
120 VAC 3" (77 mm)
GAS (131 mm)
HOT (140 mm)
Drain port 6" (152 mm)
COLD 5/8" (17 mm)
GAS 5-3/4" (147 mm)
Condens ate drain port
7-1/2" (189 mm)
COLD 6-3/4" (172 mm)
Condens ate drain port
7-7/8" (199 mm)
Can be used in both Residential and
Commercial Applications
• Exhaust & Water Temperature Safety Control.
• Overheat Cut-off Fuse.
Internal Freeze Protection System
Power Vent or Power Direct Vent Design
Warranty
• 15-year limited warranty on heat exchanger in
residential applications.
• 10-year limited warranty on heat exchanger in
commercial applications.
114
• 5-year limited warranty on all parts.
Inlet Gas Pressure Energy
Maximum
Hot/Cold
Gas
17-5/8"
(448 mm)
Minimum Maximum Factor
BTU/H
Connections Connection
(EF)
in. W.C. in. W.C.
Indoor Models
ATI-540H-N
Natural
120 VAC
6-1/4" (159 mm)
Model
Number*
Type
199,000
COLD 6-3/4" (172 mm)
• Air-Fuel Ration (AFR) Sensor.
Type
5.0
Condensate drain port
7-7/8" (199 mm)
CSA 4.3
Model
Number*
Condens ate drain port
7-1/2" (189 mm)
GAS 5-1/8" (131 mm)
ANSI Z21.10.3
Safety Features
HOT 4-3/4" (120 mm)
120 VAC 3" (77 mm)
• Multi-Link up to 20 units.
HOT 5-1/2" (140 mm)
• Easy-Link up to 4 units.
Intake
2-5/8" (68 mm)
Exhaust
2-5/8" (65 mm)
24-7/8" (631 mm)
23-5/8" (600 mm)
HOT 4-3/4" (120 mm)
Drain port
6-3/4" (170 mm)
5-3/4" (147 mm)
• Secondary heat exchanger is made of marinegrade 316L stainless steel to protect against
corrosion.
10-3/4" (272mm)
22-1/2" (570 mm)
• Primary heat exchanger of the ATI/ATO-540 is
constructed of a commercial-grade copper that is
more resilient to erosion. Copper is 25x better at
heat transfer than stainless steel thus stabilizing
outgoing water temperature quicker and reducing
pressure drop across the heat exchanger.
5-3/4" (147 mm)
GAS 5-1/8" (131 mm)
3-5/8" (92 mm)
COLD 6-3/4" (172 mm)
1-1/2" (37 mm)
Condensate drain port
7-7/8" (199 mm)
Heat Exchanger
4" (102 mm)
Female
120 VAC 6-7/8" (174 mm)
• Complies with SCAQMD 1146.2 NOx emission
requirements of 14 ng/J or 20 PPM.
11-1/4" (285 mm)
4" (101 mm)
6-1/4" (159mm)
HOT 5-1/2" (140 mm)
Ultra-Low NOx Emissions
17-3/4" (450 mm)
7" (180 mm)
4" (102 mm)
Female
24-7/8" (631 mm)
Condensing Technology Provides 0.95
Energy Factor
INDOOR MODEL
23-5/8" (600 mm)
ENERGY STAR Qualified
®
INDOOR MODEL
10.5
0.95
Sizing
Chart
COLD 5/8"
(17 mm)
(Number of Showers)
3/4” NPT
3/4” NPT
Clearance (Inches)
Cold
Warm Climate*** Top
Climate**
Bottom Side Front Back
Indoor Models
ATI-540H-N Natural
2.5
4
12
12
2
4
*For propane models, change “N” to “P” in the model number (example:ATI-540H-P)
For outdoor models change “I” to “O” in the model number (example: ATO-540-N).
**Cold climate represents 70°F temperature rise
***Warm climate represents 50°F temperature rise
0.5
115
COMMERCIAL GAS
TANKLESS HEAVY-DUTY
24-7/8" (632.9mm)
12-1/4" (311.5mm)
15" (381mm)
8" (203mm)
1/2" (11.9mm)
5" (127mm)
2-1/2" (62.1mm)
ASME Models Available
25-1/4" (642mm)
5” Category III Stainless Steel Venting
Vertical or Horizontal Venting
Installation
28-7/8" (734mm)
Commercial-Grade Copper Heat
Exchanger (Non-ASME Models)
4-7/8" (122.9mm)
Power Vent Design
1/2" (12.5mm)
Electronic Ignition
4-3/8" (110.8mm) GAS
-3/8" (137.3mm) HOT
®
Low NOx Emissions
4" (100mm) 120V
1-5/8" (40mm) COLD
6-3/4" (171.3mm) 120V
7-3/8" (186mm)GAS
5-7/8" (150mm) HOT
7-5/8" (194.3mm) COLD
Combined Indoor/Outdoor Models
Easy-Link up to 4 Units
Multi-Link up to 10 Units
10-Year Limited Warranty on Heat
Exchanger / 5-Year Limited Parts
Warranty
Model Number** Fuel Type
Gas Consumption
Input
Min.
BTU/H
Max.
BTU/H
Thermal
Efficiency
Inlet Gas
Pressure
Min.
W. C.
Max.
W. C.
GPM***
ATIO-910-N
Natural
15,000 380,000
80%
5
10.4
ATIO-910-P
Propane
15,000 380,000
82%
8
14
0.5-14.5
0.5-14.5
ATIO-910-AN*
Natural
15,000 380,000
80%
5
10.4
0.5-14.5
ATIO-910-AP*
Propane
15,000 380,000
82%
8
14
0.5-14.5
Dimensions in Inches
Model
Number**
ATIO-910-N
ATIO-910-P
ATIO-910-AN*
ATIO-910-AP*
Model
Number**
ATIO-910-N
ATIO-910-P
ATIO-910-AN*
ATIO-910-AP*
Height
Width
Depth
25-1/4
25-1/4
25-1/4
25-1/4
24-7/8
24-7/8
24-7/8
24-7/8
12-1/4
12-1/4
12-1/4
12-1/4
Volt
AMP
120
120
120
120
1.48
1.48
1.48
1.48
Flue
Intake
Hot/Cold Gas
Conn.
Approx. Shipping
Weight (lbs)
5” O.D.
5” O.D.
5” O.D.
5” O.D.
5” O.D.
5” O.D.
5” O.D.
5” O.D.
1” NPT
1” NPT
1” NPT
1” NPT
113
113
113
113
* ASME Models
**Outdoor installations require vent cap.
***Current numbers based on factory testing; 0.5 GPM required for activation; 0.4 GPM
required for continuous fire after initial ignition.
116
117
COMMERCIAL ELECTRIC
DEN/DEL ELECTRIC DURA-POWER™
TOP VIEW
DEL 6/10/15/20
OUTLET
3/4” (FEMALE)
NPT
HOT WATER OUTLET DEL-6
Glasslined Tank
3/4” NPT
RELIEF VALVE
OPENING
• Thirteen sizes, 6 thru 119 gallon capacity. Tank
interior is coated with glass specially designed by A.
O. Smith for water heater use.
“B”
ELECTRICAL
CONNECTION
Elements
• Zinc plated copper sheaths for longer life.
OUTLET
3/4” (FEMALE)
OUTLET
NPT
3/4” (FEMALE)
NPT
3/4” NPT
RELIEF VALVE
OPENING
“B”
Standard Voltages
ELECTRICAL
2 1/2”
CONNECTION
(63.5 mm)
• 120, 277 single phase and 208, 240 and 480V
unbalanced three-phase delta; easily converted to
single-phase at terminal block (except 208V with
6000 watt elements). Single element heater, singlephase only.
INLET
JUNCTION
3/4” (FEMALE)
BOX
NPT
“C”
U. S. Gallons/Hr at Temperature Rise Indicated
F°
100
/1500
GPH
6
/2000
GPH
8
/2500
GPH
GPH
GPH
GPH
GPH
GPH
10
12
16
18
20
24
GPH
GPH
GPH
GPH
GPH
24
32
36
41
49
“D”
“A”
BRASS
DRAIN
VALVE
JUNCTION
BOX
“C”
TOP VIEW
2 1/2”
DEN 30 - 120 (63.5 mm)
“B”
“A”
“A”
DRAIN
VALVE
3 3/4” (95.25 mm)
3 3/4” (95.25 mm)
FRONT VIEW
DEL 30/40/50
FRONT VIEW
DEN 30-120
Dimensions in Inches
Model
Number
Gallon
Capacity
A
B
C
D
Non-Simultaneous Operation
3000/3000
4000/4000
4500/4500
5000/5000
6000/6000
Simultaneous Operation
3000/3000
4000/4000
4500/4500
5000/5000
6000/6000
6 gallon model not available above 3.0 kW
6/10/15/20 gallon model all A6 circuit (2 wire) only
t = Non simultaneous circuit only
( ) = Simultaneous only in 3 Ph
118
INLET
3/4” (FEMALE)
NPT
3/4” NPT
RELIEF VALVE
OPENING
TOP VIEW
DEL 30/40/50
3 3/4” NPT
RELIEF VALVE
OPENING
• Factory-installed. Just bring the service to heater
and connect to block. Terminal block not supplied
on 120V & 277 volt models. (No junction box on
DEL6-20)
Element Wattage (Upper/Lower)
INLET
OUTLET
3/4” (FEMALE) 3/4” (FEMALE)
NPT
NPT
“B”VIEW
FRONT
DEL 6/10/15/20
*(NO SIDE OUTLET AVAILABLE FOR DEL-6 MODELS)
Terminal Block
“A”
FRONT VIEW
DEL 6/10/15/20
*(NO SIDE OUTLET AVAILABLE FOR DEL-6 MODELS)
ALTERNATE OUTLET
3/4” (FEMALE) NPT
“D”
“C”
INLET
3/4” (FEMALE)
NPT
TOP VIEW
DEL 6/10/15/20
• Medium watt density means lower surface
temperature to minimize scale build-up and more
surface to heat water. Element sizes from 1.5 to 6
KW. Maximum input 12 KW
ALTERNATE OUTLET
3/4” (FEMALE) NPT
Approx.
Shipping
Weight
(lbs.)
Compact Models
DEL-6S
6
15-1/2
14-1/4
11
N/A
35
DEL-10S
10
18-1/4
18
12-1/2
N/A
54
DEL-15S
15
20
26
22-1/4
18
21-3/4
20-1/2
15-3/8
N/A
N/A
58
73
30
40
50
30-7/8
32-1/4
32-1/4
21-3/4 24-1/8
24
25-9/16
26-1/2 25-1/8
8
8
8
100
125
166
30
40
50
66
80
119
34-1/2
45-1/8
54-7/8
60-3/4
59-3/8
62-7/16
20-1/2
20-1/2
20-1/2
21-3/4
24
29-3/8
8
8
8
8
8
8
98
113
131
176
211
326
DEL-20S
Lowboy Models
DEL-30D
DEL-40D
DEL-50D
Tall Models
DEN-30D
DEN-40D
DEN-52D
DEN-66D
DEN-80D
DEN-120D
N/A
N/A
N/A
N/A
N/A
N/A
S= Single Element D= Dual Elements
Dual element models wired for 3-phase 208/240/480 volt. Field convertible to 1-phase.
119
COMMERCIAL ELECTRIC
GOLD Xi SERIES
WATER
OUTLET
Advanced Electronic Control
• Plain English Text and Animated Icons Display
Diagnostics
C
iCOMM™ Compatible and Can be
Monitored from Remote Locations. Call
1.888.WATER02 for More Information.
CONDUIT
OPENING
Economy Mode Operation - Lowers
the Operating Set Point and Reduces
Operating Costs
Thermostatic Linear Sequencing Control
Helps Reduce Current Surges and
Provides Accurate Control of Water
Temperature
3/4” NPT
OPENING
Goldenrod Elements
DISPLAY FOR
ELECTRONIC
CONTROL
MODELS ONLY
• All DVE models ship standard with patented
Goldenrod 24K gold plated elements. Goldenrod
elements provide long life with superior scaling
resistance.
ASME/CRN
(optional)
Listed
3-Year Limited Tank and 1-Year Limited
Parts Warranty
A
• For complete warranty information, consult written
warranty or go to hotwater.com
INLET
OPENING
DRAIN
VALVE
5.25
B
Model
Number
DVE-52*
DVE-80
DVE-120
Dimensions in Inches
Gallon
Capacity
A
B
C
Approx. Shipping
Weight (lbs)
50
80
119
55-3/4
60-1/4
62-1/4
21-3/4
25-1/2
29-1/2
27
31
35
265
280
390
*DVE-52 is maximum 36kW
See specification sheets or contact your local rep for optional kW’s available
120
121
COMMERCIAL ELECTRIC
GOLD SERIES
WATER
OUTLET
Gold Elements
C
• DRE models ship with the Goldenrod 24K gold
plated elements (see element availability chart
on back).
• Patented Goldenrod elements provide long life and
superior scaling resistance.
CONDUIT
OPENING
• Low watt density means lower surface temperature
to minimize scale buildup and more surface to
heat water. Goldenrod elements carry a one-year
warranty against failure due to lime scale build-up.
Fusing
3/4” NPT
OPENING
• Protects all elements, thermostats, and internal
wiring circuits against excess current flow. Meets
National Electrical Code requirements that
non-ASME tanks must have internal fusing when
current draw exceeds 48 amps. Available as an
option on Canadian built heaters
Meets the Standby Loss Requirements
of the U. S. Department of Energy and
Current Edition of AHRAE/IESNA 90.1.
A
3-Year Limited Tank and 1-Year Limited
Parts Warranty
• For complete warranty information, consult written
warranty or go to hotwater.com
INLET
OPENING
DRAIN
VALVE
5.25
B
Model
Number
DRE-52
DRE-80
DRE-120
Dimensions in Inches
Gallon
Capacity
A
B
C
Approx. Shipping
Weight (lbs)
50
80
119
55-3/4
60-1/4
62-1/4
21-3/4
25-1/2
29-1/2
27
31
35
265
280
390
* DRE-52 is maximum 36kW
See specification sheets or contact your local rep for optional kW’s available
122
123
COMMERCIAL ELECTRIC
HEAVY-DUTY CUSTOM Xi
Advanced Electronic Control
• Provides Precise Temperature Control and
Plain English Text with Animated Icons Display
iCOMM™ Compatible and Can be
Monitored from Remote Locations.
Call 1.888.WATER02 for More
Information.
Low-Water Cutoff—Remote
Electronic Immersion-Type Probe to
Prevent Energizing of the Elements,
Eliminating Accidental Dry Firing
Incoloy-Sheath Heating Elements
Standard
Factory-Wired, 120V Circuit Controls
Power-Circuit Fusing for System
Protection
Glass-Lined Tank, with ASME
Construction
SA Certified and ASME Rated T&P
C
Relief Valve
BACnet and Modbus Compatible
with ICC Interface
3-Year Limited Tank and 1-Year
Limited Parts Warranty
• For complete warranty information, consult
written warranty or go to hotwater.com
Dimensions in Inches
Model
Gallon Maximum
Number Capacity kW Input
A
B
C
D
5
10
20
30
40
50
65
80
100
120
20-1/4
26-1/4
27-1/4
35-3/4
45-3/4
54-3/4
50-1/2
49-1/4
58-1/4
63-1/4
16-1/4
18-3/4
20-1/2
20-1/2
20-1/2
20-1/2
26-1/2
28
28
30
22-1/2
25
26-1/2
26-1/2
26-1/2
26-1/2
33-1/2
35
35
37
5-1/4
5-1/4
5-3/4
5-3/4
5-3/4
5-3/4
7
7
7
7-1/2
DSE-5
DSE-10
DSE-20
DSE-30
DSE-40
DSE-50
DSE-65
DSE-80
DSE-100
DSE-120
124
3
6
18
24
36
90
90
90
90
90
Approx.
Shipping
Weight
(lbs)
82
106
130
150
190
221
267
285
354
420
125
COMMERCIAL ELECTRIC
SU MODELS
HEAVY-DUTY CMC/SU BOOSTER
ELECTRIC DURA-POWER™
CMC MODELS
Incoloy-Sheath Heating Elements Standard
A. O. Smith Goldenrod® Elements Optional
Standard Voltages for Easy Installation
Immersion Thermostat for Efficient Control
Power-Circuit Fusing for System Protection
Heavy-Duty Magnetic Contactors
Factory-Wired 120V Circuit Controls
Dimensions in Inches
C
Inlet/
Outlet
Approx.
Shipping
Weight
(lbs)
13
23.5
3/4
80
12
18
23.5
3/4
96
25
22.25
23
3/4
200
Gallon
Capacity
A
B
CMC-6 through
CMC-18
5
13.75
CMC-20 through
CMC-54
5
SU-6 through SU-54
20
Model Number
3-Year Limited Warranty
SU MODELS
*CMC-6 and SU-54 have three dimension heaters.
126
127
COMMERCIAL ELECTRIC
AIR-TO-WATER ELECTRIC HEAT-PUMPS
Air-to-water heat pump water heaters remove unwanted
heat and humidity from the surrounding air and use it to
heat water. The refrigeration-based system produces cool,
dehumidified air for spot cooling or to reduce the load on air
conditioning systems.
High Efficiency Water Heating
“Environmentally-Friendly” Green Technology uses Non-Ozone
Depleting R-134a Refrigerant
Model
Number
Simplified Installation
Efficient Scroll Compressor
Sanitary Hot Water for Commercial or Industrial use
Coefficient Performance (COP) Between 3.9 and 4.2 for Water
Heating
Standard 208/230 VAC, Tri-Phase Power (Optional 460 VAC, Triphase)
Maximum 140°F Final Tank Temperature at Common Indoor Temps
Accessories Include:
• Digital temp controller with tank probe
AWH-35
AWH-55
AWH-75
AWH-100
AWH-115
AWH-140
AWH-170
Water
Heating
Capacity
Dimensions in Inches
Btu/hr*
Inlet/
Outlet
Water
A
B
C
Approx.
Shipping
Weight
(lbs)
35,500
58,000
76,000
98,000
113,000
142,000
171,000
1
1
1.5
1.5
1.5
2
2
40
47
57
63
63
63
75
26
32
32
38
38
38
46
24.75
28.50
28.50
42.50
42.50
42.50
42.50
315
405
485
660
665
725
880
*Performance rating at 75º F, 55% Relative Humidity and 100ºF incoming water
temperature
**Blower design at 0.35” external static pressure
C.O.P. coefficient of performance
All models standard 208/230V, Tri-phase, 60 Hz.
Optional 460v Tri-phase 60Hz
Optional 240v Single Phase 60Hz (available on AHW-35 and AHW-55 only)
• Metal mesh cleanable filter
• Corrosive duty package; 316 stainless steel cabinet, polyurethane coated evaporator coil
and blower housing. Recommended for coastal areas.
5-Year Compressor Limited Warranty/1-Year Parts Limited Warranty
• For complete warranty information, consult written warranty or go to hotwater.com
128
129
COMMERCIAL ELECTRIC
HEAVY-DUTY PREMIUM ELECTRIC
DVE/DHE DURA-POWER™
Advanced Electronic Control A. O.
Smith’s New Propriety Electronic
Water Heater Control, Provides
Precise + or - 1ºF Temperature
Control, that is Ideal for Industrial
and Food Service Applications where
Exact Temperatures of Hot Water are
Needed.
iCOMM™ Compatible and Can be
Monitored from Remote Locations.
Call 1.888.WATER02 for More
Information.
Recovery
Standard Number of
Capacity
BTU Input
kW
Immersion
GPH @
and Output
Ratings Heaters
100°F
Rise
Recovery
Standard Number of BTU
Capacity
kW Immersion Input and GPH @
Ratings Heaters Output
100°F
Rise
Solid State Step Control
XI On/Off
180
12-15kW
614,340
738
15
210
14-15kW
716,730
861
XI Progressive
240
16-15kW
819,120
987
24
2-12kW
81,912
98
270
18-15kW
921,510
1,107
30
2-15kW 102,390
123
300
20-15kW 1,023,900
1,230
36
3-12kW 122,868
147
330
22-15kW 1,126,290
1,353
45
3-15kW 153,585
184
360
24-15kW 1,228,680
1,476
60
4-15kW 204,720
246
390
26-15kW 1,331,070
1,599
75
5-15kW 255,975
307
420
28-15kW 1,433,460
1,722
90
6-15kW 307,170
369
105
7-15kW 358,365
430
120
8-15kW 409,560
492
150
10-15kW 511,950
615
450
30-15kW 1,535,850
1,845
480
32-15kW 1,638,240
1,968
510
34-15kW 1,740,630
2,091
540
36-15kW 1,843,020
2,214
570
38-15kW 1,945,410
2,337
600
40-15kW 2,047,800
2,460
630
42-15kW 2,150,190
2,583
660
44-15kW 2,252,580
2,706
690
46-15kW 2,345,970
2,829
720
48-15kW 2,457,360
2,952
810
54-15kW 2,764,530
3,321
900
60-15kW 3,071,700
3,690
Heavy-Duty Magnetic Contactors
990
66-15kW 3,378,870
4,059
1080
72-15kW 3,686,040
4,428
Factory-wired, 120V Circuit Controls
1170
78-15kW 3,993,210
4,797
1260
84-15kW 4,300,380
5,166
1350
90-15kW 4,607,550
5,535
Low-Water Cutoff
1440
96-15kW 4,914,720
5,904
1530
102-15kW 5,221,890
6,273
Glass-Lined Tank (Standard)
1620
108-15kW 5,529,060
6,642
1800
120-15kW 6,141,600
7,380
1980
132-15kW 6,757,740
8,118
2040
136-15kW 6,962,520
8,364
2220
148-15kW 7,576,860
9,102
2250
150-15kW 7,679,250
9,225
2400
160-15kW 8,188,800
9,840
2540
176-15kW 9,010,320 10,824
2820
188-15kW 9,624,660 11,562
3000
200-15kW 10,236,000 12,300
Progressive Modulating- Sizes the
Input of Available Elements to Match
Current Load Conditions. Rotates and
Lead Lags Element Loads to Provide
Long Life and Equal Wear.
Heavy-Duty Incoloy-Sheath Heating
Elements
240V, 480V and 600V
Factory-Installed Terminal Block
Power-Circuit Fusing
Handhole Clean-Out(s)
Color-Coded Circuitry
CSA Certified and ASME Rated T&P
Relief Valve
1-15kW
51,195
61
Complete model number includes the desired kw at the end, minimum installation
Clearances required: 30˝ from front, 12˝ from top and 24˝ from right side
BACnet and Modbus connectivity available with the ICC Gateway device on models with
150 kW or less
130
131
COMMERCIAL ELECTRIC
HEAVY-DUTY PREMIUM ELECTRIC
DVE/DHE DURA-POWER™ (CONTINUED)
Model
Number
Nominal
Gallon
Capacity
Dimensions in Inches
A
B
C
D
E
77
91
81
93
100
94
109
121
111
111
138
150
177
211
296
317
345
36
36
42
42
42
48
48
48
54
60
60
60
66
72
78
90
102
10-1/2 17-1/2
10-1/2
24
8-1/4
17
8-1/4
23
8-1/4 26-1/2
14
24
14
32
14
38
16-1/2
32
16-1/2 29-1/2
16-1/2
43
16-1/2
50
20
60
20
72-1/2
20-1/2 113-1/2
20-1/2
121
22
132
30
30
36
36
36
42
42
42
48
48
48
56
60
60
60
66
72
78
90
102
37
37
43
43
43
49
49
49
55
55
55
61
67
67
67
73
79
85
97
109
16
16
17-1/2
17-1/2
17-1/2
19
19
19
21
21
21
23
24-1/2
24-1/2
24-1/2
25
27-1/2
30
30
30
F
Horizontal Electric Storage Heater
DHE-200
DHE-250
DHE-300
DHE-350
DHE-400
DHE-500
DHE-600
DHE-700
DHE-800
DHE-1,000
DHE-1,250
DHE-1,500
DHE-2,000
DHE-3,000
DHE-5,000
DHE-7,500
DHE-10,000
200
250
300
350
400
500
600
700
800
1,000
1,250
1,500
2,000
3,000
5,000
7,500
10,000
38-1/2
38-1/2
44-1/2
44-1/2
44-1/2
51
51
51
57
61
61
61
70
76
82
94
106
31
48
36
48
55
48
64
76
64
59
86
98
120
131
195
218
220
Vertical Electric Storage Heater
DVE-140
DVE-150
DVE-150L
DVE-200
DVE-250
DVE-300
DVE-350
DVE-400
DVE-500
DVE-600
DVE-700
DVE-800
DVE-1000
DVE-1250
DVE-1500
DVE-2000
DVE-3000
DVE-5000
DVE-7500
DVE-10,000
132
140
150
150
200
250
300
350
400
500
600
700
800
1,000
1,250
1,500
2,000
3,000
5,000
7,500
10,000
83-1/2
83-1/2
59-1/2
79-1/2
93
83-1/2
95-1/2
102-1/2
97
112
124
116
116
143
155
183
217
309
330
358
6
6
6
6
6
6
6
6
6
6
6
8
10
10
10
12
14
14
14
14
17
17
21
21
21
25-1/2
25-1/2
25-1/2
30
30
30
34
38
38
38
42-1/2
47
51
59-1/2
68
Complete model number includes the desired kW at the end (example: DVE-140-120)
Minimum installation clearances required: 30˝ from front, 12˝ from top and 24˝ from right
side
150 gallon available in both tall (T) and short (S) models
BACnet and Modbus connectivity available with the ICC Gateway device on models with
150 kW or less
133
COMMERCIAL
XP DOMESTIC WATER HEATERS
Up to 99% in Low Temperature
Applications
Super Alloy Metal Fiber Burners
20:1 Turndown Models 2 Million BTUH
and up, 10:1 Turndown Models 1.7
Million BTUH and Down
Recovery Capacities
ASME Rated Relief Valve
160 lb. ASME Working Pressure
Factory-Installed Bronze Circulating
Pump
Adjustable Pump Delay
Honeywell Sola Control with Color Touch
Screen LCD Display
Multi-Burner Sequencing Models 2
Million BTUH and up Have 4 Burners;
Models 1.7 Million BTUH and Down
Have 2 Burners
Redundant Flow and Low Water
Protection-Factory Installed LWCO and
Flow Switch(s)
®
Manual Reset High Limit
CRN
316L Stainless steel Heat Exchanger(s)
Professional Start-Up Included Required for Activating Warranty
and Assuring Maximum Operating
Performance
Meets the requirements of South
Coast Air Quality Management
District in Southern California and the
requirements of Texas Commission on
Environmental Qualities.
5-year Heat Exchanger and 1-Year Parts
Limited Warranty
Model Number
XWH-1000
XWH-1300
XWH-1700
XWH-2000
XWH-2600
XWH-3400
BTU/HR Natural Gas
Input
Water
Flow
920,000
1,300,000
1,700,000
2,000,000
2,600,000
3,400,000
GPH
GPH
GPH
GPH
GPH
GPH
Temperature Rise °F
100
1,065
1,497
1,962
2,317
3,000
3,956
Simple Heat Exchanger Model Dimensions
Models
XWH-1000
XWH-1300
XWH-1700
Dimensions in Inches
Flue Outlet
Diameter
6
8
8
Air Intake
Diameter
6
6
8
49
68
29
38
23
9
34
45
6
11
11
2-1/2 inch NPT
2-1/2 inch NPT
2 inch NPT
57
76
29
37
24
9
34
45
6
11
12
2 inch NPT
2 inch NPT
2 inch NPT
Wat Inlet
Water Outlet
Gas Inlet
A
B
C
D
E
F
G
H
J
K
L
47
67
29
37
23
9
34
44
6
11
12
• For complete warranty information consult written
warranty or go to hotwater.com
134
135
COMMERCIAL
XP DOMESTIC WATER HEATERS
(CONTINUED)
Recovery Capacities
Model Number
BTU/HR Natural
Gas Input
Recovery Capacity
GPH @ 100°F Rise
Approx.
Shipping
Weight (lbs)
920,000
1,300,000
1,700,000
2,000,000
2,600,000
3,400,000
1,065
1,497
1,962
2,317
3,000
3,956
865
1065
1140
1485
1830
2175
XWH-1000
XWH-1300
XWH-1700
XWH-2000
XWH-2600
XWH-3400
Double Heat Exchanger Model Dimensions
Models
XWH-2000
XWH-3400
Flue Outlet
Diameter
8
8
10
Air Intake
Diameter
8
8
10
49
80
37
22
41
6
10
4
19
12
4 inch NPT
4 inch NPT
3 inch NPT
57
91
37
22
41
6
10
4
19
13
3 inch NPT
3 inch NPT
2 inch NPT
Wat Inlet
Water Outlet
Gas Inlet
A
B
C
D
E
F
G
H
J
K
136
XWH-2600
Dimensions in Inches
47
78
36
22
40
7
10
4
20
12
137
COMMERCIAL WATER HEATER
BURKAY® GENESIS® DOMESTIC
WATER HEATER
B
F
AIR
INLET
GAS
CO NN ECTION
G
F
EXHAUST
VENT
EXHAUST
VENT
G
GAS
CO NN ECTION
INLET
INLET
OUTLET
85% Thermal Efficiency
OUTLET
A
Stage Gas Firing System - Prevents
Short Cycling and Ensures Smooth
Operation, Saves Fuel and Extends
Product Life
H
H
E lectronic Control with Precise
Temperature Management
E
E
C
D
DR AIN
DR AIN
J
SIDE VIEW
J
K
K
L
L
GWH-400 THRU GWH-750
GWH-1000 THRU GWH-2100
Low NOx Operation
F
AIR
INLET
B
GAS
CO NN ECTION
G
INLET
Copper Finned-Tube Heat Exchanger
OUTLET
Space-Saving Design-Optional Stack
Rack Allows One Unit to be Stacked
on Top of Another, Doubling Output
within the Footprint of a Single Unit
®
SIDE VIEW
A
E
C
Meets ASHRAE/IESNA 90.1-2004
D
DR AIN
K
L
Multiple Venting Options
Factory Start-up Included
5-Year Heat Exchanger and 1-Year
Parts Limited Warranty
• For complete warranty information, consult
written warranty or go to hotwater.com.
Model
Number
GWH-400N
GWH-500N
GWH-650N
GWH-750N
GWH-1000N
GWH-1250N
Model
Number
GWH-400N
GWH-500N
GWH-650N
GWH-750N
GWH-1000N
GWH-1250N
GWH-1450N
GWH-1800N
GWH-2100N
Input MBH
Recovery Capacity GPH @
100°F Rise
Approx. Shipping
Weight (lbs)
399
500
650
750
990
1,260
1,440
1,800
2,070
412
515
670
773
1,020
1,298
1,484
1,855
2,133
454
467
551
611
843
939
1,035
1,168
1,285
When ordering propane change “N” to “P” in the model number (example GWH-750P)
J
SIDE VIEW
GWH-1450N
GWH-1800N
GWH-2100N
Model
Number
GWH-400N
GWH-500N
GWH-650N
GWH-750N
GWH-1000N
GWH-1250N
GWH-1450N
GWH-1800N
GWH-2100N
GWH-400 THRU GWH
Dimensions in Inches
A
B
C
D
E
F
31-1/2
31-1/2
31-1/2
31-1/2
36
36
36
36
36
7
7
8-1/2
8-1/2
8-3/4
9-3/4
10-1/2
11
11
37-5/8
45-3/8
56-3/4
64
48-1/2
58-3/4
68-7/8
82-3/8
92-5/8
8-7/8
8-7/8
8-7/8
8-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
12-1/2
12-1/2
12-1/2
12-1/2
15-7/8
15-7/8
15-7/8
15-7/8
15-7/8
7
7
8-1/2
8-1/2
22-1/2
22-1/2
22-1/2
22-1/2
22-1/2
Dimensions in Inches
G
H
J
K
L
3-1/4
3-1/4
3-1/4
3-1/4
8-1/2
9-3/4
10-1/4
10-7/8
10-7/8
29-3/4
29-3/4
29-3/4
29-3/4
33-3/4
33-3/4
33-3/4
33-3/4
33-3/4
6-3/8
6-3/8
6-3/8
6-3/8
8-3/4
8-3/4
8-3/4
8-3/4
8-3/4
12-5/8
12-5/8
12-5/8
12-5/8
19-7/8
19-7/8
19-7/8
19-7/8
19-7/8
22-1/4
22-1/4
22-1/4
22-1/4
33
33
33
33
33
When ordering propane change “N” to “P” in the model number (example GWH-750P)
138
139
COMMERCIAL WATER HEATER
VARIABLE FIRE™ HIGH-EFFICIENCY
WATER HEATERS
FF
FF
GAS
GAS
CO
CONN
NNECTION
ECTION
GG
GAS
GAS
CO
CONN
NNECTION
ECTION
AIR
AIR
INLET
INLET
GG
AIR
AIR
INLET
INLET
INLET
INLET
Up to 87% Thermal Efficiency
HH
HH
INLET
INLET
OUTLET
OUTLET
OUTLET
OUTLET
Advanced Modulating Control with
Venturi-Mixing Gas/Air Ratio System
AA
EXHAUST
EXHAUST
VENT
VENT
EE
EE
Small Footprints, Zero Clearance to
Combustibles on Sides of Unit
Category II and IV listed - Requires
the use of AL29-4C a vent material
that resists the effects of corrosive
condensates
JJ
BB
SIDE
SIDEVIEW
VIEW
Complies with SCAQMD Rule 1146.2 and
Other Air Quality Management Districts
with Similar Requirements for Low NOx
emissions
D1
D1
D2
D2
PP
PP
• For complete warranty information, consult written
warranty or go to hotwater.com.
F
VWH1500N
VWH2000N
H
OU
140
EXH
VEN
A
E
K
J
B
L
DR AINS
(3/4 " NPT)
C
M
N
D1
D2
SIDE VIEW
P
REAR VIEW
REAR
VIEW
(VWH0500N-VWH1000N)
*Pump shipped loose
Model
Number
Dimensions in Inches
A
B
VWH0500N 44-1/2 30-3/8
VWH0750N 52-1/8 30-3/8
VWH1000N 59-1/4 30-3/8
BTU/Hr Input
Recovery Capacity
GPH @ 100°F Rise
Approx. Shipping
Weight (lbs)
Model
Number
500,000
750,000
999,999
1,500,000
2,000,000
527
791
1054
1582
2109
573
622
662
1,118
1,187
VWH0500N
Change “N” to “P” when ordering propane (LP) gas (Example: VWH-750-P).
AIR
INL
G
INLET
VWH2000N 76-5/8 31-5/8
VWH1000N
REAR
REARVIEW
VIEW
(VWH1500N-VWH2000N)
(VWH1500N-VWH2000N)
GAS
CO NN ECTION
VWH1500N 65-3/8 31-5/8
VWH0750N
REAR
REARVIEW
VIEW
REAR
REARVIEW
VIEW
REAR
REAR
VIEW
VIEW
(VWH0500N-VWH1000N)
(VWH0500N-VWH1000N)
*Pump
*Pumpshipped
shippedloose
loose
EXHAUST
EXHAUST
VENT
VENT
LL
MM
NN
Professional Start-Up Included - Required
for Activating Warranty and Assuring
Maximum Operating Performance
5-Year Heat Exchanger and 1-Year Parts
Limited Warranty
VWH0500N
DR
DRAINS
AINS
(3/4"
(3/4"NPT)
NPT)
MM
NN
Meets Thermal Efficiency and Standby
Loss Requirements of the U.S. Department
of Energy and Current Edition of ASHRAE/
IESNA 90.1
Model Number
JJ
LL
DR
DRAINS
AINS
(3/4
(3/4""NPT)
NPT)
CC
Capable of Firing from 100% to 25% (or
a 4:1 Turndown Ratio) of the Rated Input,
Based on the Current System Demand
®
KK
KK
VWH0750N
VWH1000N
VWH1500N
VWH2000N
C
D1
D2
E
F
G
6
6
6
8
8
12-1/2
12-1/2
12-1/2
16-1/2
16-1/2
15-1/8
15-1/8
15-1/8
19-3/8
19-3/8
34-1/8
41-3/4
48-7/8
58-3/4
70
19-5/8
19-5/8
19-5/8
21-1/8
21-1/8
7-3/4
7-3/4
7-3/4
9-1/2
9-1/2
Dimensions in Inches
H
J
K
L
M
N
P
7-3/8
7-3/8
7-3/8
9-1/2
9-1/2
11-3/8
11-3/8
11-3/8
22
27-3/8
23
30-1/2
37-5/8
43-1/4
54-3/8
6-1/2
6-1/2
6-1/2
5-3/4
5-3/4
11-1/2
11-1/2
11-1/2
13-1/2
13-1/2
17-1/2
17-1/2
17-1/2
21-3/8
21-3/8
23-1/8
23-1/8
23-1/8
27-1/8
27-1/8
Authorized start-up service included-required to activate warranty.
Consult your local factory representative (Continental U.S. Only).
Change “N” to “P” when ordering propane (LP) gas (Example: VWH-750-P).
141
COMMERCIAL WATER HEATER
BURKAY® ENERGY SAVER COPPER
HEAT EXCHANGER
H
L
WATER
OUTLET
All Non-Ferrous Waterways
• Rustproof because water comes in contact with
nothing but copper, brass or bronze
A
• Copper transfers heat eight times faster than
ferrous metals yet offer remarkable structural
strength without excessive weight
• Free from the effects of thermal shock
C
Efficiency Copper Coil Combustion
Chamber
• Continuous coils of tightly wound copper tubing
form a unique combustion chamber
B
D
M
WATER
INLET
F
E
W
• Water circulating thru the coils, around the flame,
captures radiant heat which may otherwise be
lost
J
High Efficiency Stainless Steel Burner
• Developed especially for A. O. Smith water
heaters using the very latest burner principles
G
Forced Water Cirrculation Improves
System Efficiency
K
• Water moving at 2 to 4 feet per second helps to
prevent lime buildup and also scrubs extra heat
from the copper coil combustion chamber
M WATER INLET
Model
Input Rating BTU/Hr.
Natural & Propane Gas
Temperature
Rise-100°F
Gallons Per
Hour
Models
HWH-120
A
49-3/8
30-3/8
23-5/8
20-3/4
5-1/2
10
11-13/16
6
26-11/16
20-3/4
1-1/4 NPT
1 NPT
1/2 NPT
1-3/4
120 lbs.
160,000
154
HW-200M
199,000
195
C
217
D
225,000 Nat. Gas Only
B
E
F
G
H
J
K
L
M
N
W
Approx.
Shipping
Weight
142
HWH-160
HWH-200
HWH-225
50-1/8
30-3/8
23-5/8
20-3/4
5-1/2
10
11-13/16
7
26-11/16
20-3/4
1-1/4 NPT
1 NPT
1/2 NPT
1-3/4
53-1/4
33-1/8
27-1/8
20-3/4
5-1/2
10
11-13/16
7
26-11/16
20-3/4
1-1/4 NPT
1 NPT
1/2 NPT
1-3/4
60
33-1/8
27-1/8
20-3/4
5-1/2
10
11-13/16
7
26-11/16
20-3/4
1-1/4 NPT
1 NPT
1/2 NPT
1-3/4
155 lbs.
165 lbs.
175 lbs.
Dimensions in Inches
HW-160M
HW-225M
N
GAS
L
INLET
WATER
OUTLET
143
E
HOT WATER SUPPLY BOILERS
BURKAY® HW GAS DOMESTIC
WATER HEATERS & BOILERS
F
EXTRA OPENING
FOR THERMOMETER
AND PRESSURE
RELIEF VALVE
HW-520 AND
H
HW-670
HW-300
All Non-Ferrous Waterways
• All water tubes are made from copper
• Brazed joints or flare union construction make
the boiler immune to the effects of thermal shock
and thermal cycling
L INLET
NPT
E
• The combustion chamber is a heat exchanger
formed from a two passage coil of tightly wound
continuous copper tube
G
J
EXTRA OPENING
FOR THERMOMETER
AND PRESSURE
Dimensions
in Inches T
RELIEF
VALVE
HW-520 AND
H
HW-670
A
B
®
Models
HW-300
HW-399
HW-420
HW-520
65
57-1/8
57-1/8
68-5/16 68-5/16
45-1/8
45-1/8
56-1/4
56-1/4
38-3/4
38-3/4
46
46
Overall height
S
Height to Top of
Jacket
P
43-1/4
HW-300
HW-399
HW-420
HW-520
HW-670 Nat.
HW-670 Prop
144
Recovery Capacity
GPH @ 100°F Rise
Approx.
Shipping
Weight (lbs)
300,000
399,000
420,000
520,000
660,000
670,000
298
392
417
516
656
656
255
301
301
381
381
381
HW-670
K
C
Floor to Center
Line Water Outlet
D
Diameter of
Jacket OF
25-1/4
LOCATION
MANUAL
27
27
27
27
E
Floor to Center
OUTSIDE JACKET WHEN
12
12
Line WaterCODE
Inlet REQUIRE
(NOT SUPPLIED)
12
12
12
36
MAIN SHUTOFF VALVE
Input Rating BTU/HR
Natural & Propane
(LP) Gas
LOCATION OF MANUAL
MAIN SHUTOFF VALVE
OUTSIDE JACKET WHEN
CODE REQUIRE
(NOT SUPPLIED)
B
N
GAS INLET
(MALE) NPT
Efficiency Copper Coil Combustion
Chamber
• A wrap of insulation on the outside of the coil
retains the heat captured by the circulating water
K
A
D
C
• Water circulating through this coil surrounds the
main burner and captures the radiant heat
S
M
OUTLET
NPT
• A great boiler for domestic hot water supply
T
P
F
• All castings are made of bronze or brass
Model Number
G
J
F
Draft Diverter
Outlet Diameter
8
10
10
10
12
G
Floor to Center
Line Gas Inlet
16-1/2
16-3/4
16-3/4
8
8
29-5/8
9
31-1/2
9
31-1/2
9
36-1/2
9
36-1/2
9
H
Overall Depth
J
Support Height
K
Width of Control
String (approx.)
14
14
14
11
11
L
Pipe Size of Water
Inlet (NPT)
1-1/4
1-1/2
1-1/2
2
2
M
Pipe Size of Water
Outlet (NPT)
1-1/4
1-1/2
1-1/2
2
2
N
Pipe Size of Gas
Inlet (NPT)
3/4
3/4
1
1
1
P
Control String Plus
1/2 Jacket Diameter (approx.)
26-5/8
27-1/2
27-1/2
24-1/2
24-1/2
S
Horizontal Length
between Water
Inlet & Outlet
5-3/8
5-1/2
5-1/2
5-3/4
5-3/4
T
Control String from
Jacket
5
5
5
7
7
145
COMMERCIAL ELECTRIC BOILERS
DURA-POWER™ NW ELECTRIC BOILERS
UL MINIMUM CLEARANCE REQUIRMENTS:
24” ALL SIDES, 12” TOP
NOTE: ALLOW 30” CLEARANCE FOR HINGED CONTROL
COMPARTMENT DOORS.
ELEMENTS CAN BE CHANGED WITH 24” CLEARANCE.
AN ADDITIONAL CONTROL PANEL IS REQUIRED ON
UNITS ABOVE 500kW RATED AT 208 OR 240 VOLTS.
MODELS: NW-37, NW-60, NW-96 AND NW-150
ASME Code Construction
Incoloy Immersion Heaters
Control and Power Circuit Fusing
Pilot Switch and Light
Heavy-Duty UL-Rated Magnetic Contactors Rated for 100,000
Low-Water Cutoff
120V Control Circuit
Modulating Step Control
1-Year Limited Tank Warranty
• For complete warranty information, consult written warranty or go to hotwater.com.
Model
Number
NW-37
NW-60
NW-96
NW-150
NW-220
NW-334
NW-400
NW-500
NW-570
Nominal
Maximum
Gallon
kW Input
Capacity
37
60
96
150
220
334
400
500
670
180
300
480
720
1140
1740
2100
2580
3300
Dimensions in Inches
A**
B
C
D
E
F
42
57
69-1/2
69-1/2
71
99
90-1/2
90-1/2
96-1/2
32
32
36
54
60
60
66
72
78
30
30
38
44
50
50
56
62
68
12-1/2
12-1/2
17
20
21
25
25-1/2
26-1/2
30-1/2
12
12
16
19
25
25
28
31
34
20
20
24
27
30
30
33
36
39
G
H
4
4
5
17
5-1/2 20
5-1/2 25-1/2
7-1/4 25-1/2
7-3/4 30
7-3/4 34
7-3/4 38
See heater specification sheet for additional features and options.
More information on the following page.
146
147
COMMERCIAL ELECTRIC BOILERS
DURA-POWER™ NW ELECTRIC BOILERS
(CONTINUED)
NW-37-60-K
NW-37-75-K
NW-37-90-K
NW-37-105-K
NW-37-120-K
NW-37-150-K
NW-37-180-K
NW-60-210-K
NW-60-240-K
NW-60-270-K
NW-60-300-K
NW-96-330-K
NW-96-360-K
NW-96-390-K
NW-96-420-K
NW-96-450-K
NW-96-480-K
NW-150-540-K
NW-150-600-K
NW-150-660-K
NW-150-720-K
NW-220-780-K
NW-220-840-K
NW-220-900-K
NW-220-960-K
NW-220-1020-K
NW-220-1080-K
NW-220-1140-K
NW-334-1200-K
NW-334-1260-K
NW-334-1380-K
NW-334-1500-K
NW-334-1620-K
NW-334-1740-K
NW-400-1800-K
NW-400-1860-K
NW-400-1980-K
NW-400-2100-K
NW-500-2220-K
NW-500-2340-K
NW-500-2460-K
NW-500-2580-K
NW-670-2700-K
NW-670-2820-K
NW-670-2940-K
NW-670-3060-K
NW-670-3180-K
NW-670-3300-K
148
Standard
Wattage
kW
37
37
37
37
37
37
37
37
60
60
60
60
96
96
96
96
96
96
150
150
150
150
220
220
220
220
220
220
220
334
334
334
334
334
334
400
400
400
400
500
500
500
500
670
670
670
670
670
670
45
60
75
90
105
120
150
180
210
240
270
300
330
360
390
420
450
480
540
600
660
720
780
840
900
960
1,020
1,080
1,140
1,200
1,260
1,380
1,500
1,620
1,740
1,800
1,860
1,980
2,100
2220
2340
2460
2580
2700
2820
2940
3060
3180
3300
Recovery
BTU Output Capacity GPH @
100°F Rise
153,585
204,720
255,975
307,170
358,365
409,560
511,950
614,340
716,730
819,120
921,510
1,023,900
1,126,290
1,228,680
1,331,070
1,433,460
1,535,850
1,638,240
1,843,020
2,047,800
2,252,580
2,457,360
2,662,140
2,866,920
3,071,700
3,276,480
3,481,260
3,636,040
3,890,820
4,095,600
4,300,380
4,709,940
5,119,500
5,529,060
5,938,630
6,143,400
6,348,180
6,757,740
7,167,300
7,576,860
7,986,420
8,395,980
8,805,540
9,315,100
9,624,660
10,034,220
10,443,780
10,853,340
11,262,900
180
240
300
369
430
492
615
736
861
984
1,107
1,230
1,353
1,476
1,599
1,722
1,845
1,968
2,214
2,460
2,706
2,952
3,198
3,444
3,690
3,936
4,182
4,428
4,674
4,920
5,166
5,658
6,150
6,642
7,134
7,380
7,626
8,118
8,610
9,102
9,594
10,080
10,578
11,070
11,562
12,054
12,546
13,038
13,530
Number of
Immersion
Heaters
3
4
5
6
7
8
10
12
14
16
18
20
22
24
26
28
30
32
36
40
44
48
52
56
60
64
68
72
76
80
84
92
100
108
116
120
124
132
140
148
156
164
172
180
188
196
204
212
220
Model Number
Steps
Standard Number and
(Standard)
kW of Steps
NW-37-45-K
NW-37-60-K
NW-37-75-K
NW-37-90-K
NW-37-105-K
NW-37-120-K
NW-37-150-K
NW-37-180-K
NW-60-210-K
NW-60-240-K
NW-60-270-K
NW-60-300-K
NW-96-330-K
NW-96-360-K
NW-96-390-K
NW-96-420-K
NW-96-450-K
NW-96-480-K
NW-150-540-K
NW-150-600-K
NW-150-660-K
NW-150-720-K
NW-220-780-K
NW-220-840-K
NW-220-900-K
NW-220-960-K
NW-220-1020-K
NW-220-1080-K
NW-220-1140-K
NW-334-1200-K
NW-334-1260-K
NW-334-1380-K
NW-334-1500-K
NW-334-1620-K
NW-334-1740-K
NW-400-1800-K
NW-400-1860-K
NW-400-1980-K
NW-400-2100-K
NW-500-2220-K
NW-500-2340-K
NW-500-2460-K
NW-500-2580-K
1
1
1
3
4
4
5
5
5
5
5
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
18
18
18
NW-670-2700-K
19
NW-670-2820-K
NW-670-2940-K
NW-670-3060-K
NW-670-3180-K
18
18
18
18
NW-670-3300-K
18
1 @ 45
1@ 60
1 @ 75
3 @ 30
3 @ 30 +1 @15
4 @ 30
5 @ 30
4 @ 30 + 1@ 60
3 @ 30 + 2 @ 60
2 @ 30 + 3 @ 60
1 @ 30 + 4 @ 60
5 @ 60
9 @ 30 + 1 @ 60
8 @ 30 + 2 @ 60
7 @ 30 +3 @60
6 @ 30 + 4 @ 60
5 @ 30 + 5 @ 60
4 @ 30 + 6 @ 60
2 @ 30 + 8 @ 60
10 @ 60
8 @ 60 + 2 @ 90
6 @ 60 + 4 @90
4 @ 60 + 6 @ 90
9 @ 90 + 1 @ 30
10 @ 90
8 @ 90 + 2 @ 120
6 @ 90 + 4 @ 120
4 @ 90 + 6 @ 120
2 @ 90 + 8 @ 120
10 @ 120
8 @ 120 + 2 @ 150
4 @ 120 + 6 @ 150
10 @ 150
6 @ 90 + 9 @120
2 @ 90 + 13 @ 150
15 @ 120
13 @ 120 + 2 @ 150
9 @ 120 + 6 @ 150
5 @ 120 + 10 @ 150
1 @ 120 + 14 @ 150
18 @ 120 + 2 @ 90
18 @ 120 + 2 @ 150
14 @ 120 + 6 @ 150
10 @ 120 + 10 @
150
6 @ 120 + 14 @ 150
2 @ 120 + 18 @ 150
18 @ 150 + 2 @ 180
14 @ 150 + 6 @ 180
10 @ 150 + 10 @
180
208V
Amperage 3 Phase
240V
480V
575V
128
171
213
250
292
334
417
500
584
668
751
834
917
1001
1084
1168
1251
1334
150
1668
108
144
180
217
253
289
361
433
505
577
650
722
794
866
938
1010
1083
1155
1299
1443
NOT RECOMMENDED
NW-37-45-K
Gallon
Capacity
NOT RECOMMENDED
Model Number
55
73
90
108
126
144
180
216
252
288
324
360
396
432
468
504
540
576
648
720
792
864
936
1008
1080
1152
1224
1296
1368
1440
1512
1656
1800
1944
2068
2160
2232
2376
2520
2664
2808
2952
3096
45
60
75
90
105
121
151
181
211
241
271
301
331
362
392
422
452
487
542
602
663
723
783
843
904
964
1024
1084
1145
1205
1265
1386
1506
1627
1747
1807
1868
1988
2109
2229
2350
2470
2590
3240
2711
3384
3528
3672
3816
2832
2952
3073
3193
3960
3313
149
HOT WATER GENERATOR
STEAM OR BOILER HOT WATER
HWG GENERATOR SYSTEMS
All HWG Systems are Fiberglass
Insulated and Jacketed
Integral Bronze Circulator Pump
oth Steam and Boiler Water Units
B
are Custom Built to Meet Your
Specifications and are Completely
Assembled with Components Sized,
Piped, and Checked Before Shipping
ASME Rated
Cathodic Protection
Custom Sizes Available up to 12,000
Gallons
Available in Vertical or Horizontal
Models
5 -Year Limited Tank Warranty and
1-Year Limited Coil Warranty
OPTIONAL
Table
HWG-2
• For complete warranty information, consult
written warranty or go to hotwater.com.
Gals./Hr Recovery (Based on Circulating Tank)
Steam Press
in Coil (PSIG)
180°F Boiler Water
Minimum GPM Required
212°F Boiler Water
Minimum GPM Required
Dimensions in Inches
Coil Sizes (Diameter - Length)
Model
Gal
A
B
C
D
E
HWG48-1000V
140
200
350
400
500
750
1000
89
85
102
107
86
118
150
30
36
42
42
54
54
54
22
24
25-1/2
25-1/2
30
30
30
11-1/4
15-1/2
19
19
25-1/2
25-1/2
25-1/2
2-1/2
2-1/2
2-1/2
2-1/2
3
3
3
Model
Gal
A
B
C
D
E
F
200
350
400
500
750
1000
77
93
99
79
111
143
41
47
47
59
59
59
16
16
17
23
23
23
26
30
30
42
42
42
2-1/2
2-1/2
2-1/2
3
3
3
36
42
42
54
54
54
4-18
4-36
6-24
6-36
6-54
HWG24-140V
45
4
69
6
87
7
135
12
149
13
230
20
223
19
346
29
335
28
518
43
HWG30-200V
HWG36-350V
HWG36-400V
HWG48-500V
HWG48-750V
Table
HWG-2
Gals./Hr Recovery (Based on Circulating Tank)
Steam Press in
Coil (PSIG)
8-42
180°F Boiler Water
Minimum GPM Required
212°F Boiler Water
Minimum GPM Required
Coil Sizes (Diameter - Length)
8-60 10-42 10-48 12-36 12-48 14-42
502 707 949 1079 1135 1544 1823
42
59
79
90
95
129 152
778 1094 1469 1670 1757 2390 2822
65
91
122 140 146 200 235
Dimensions in Inches
HWG30-200H
HWG36-350H
HWG36-400H
HWG48-500H
HWG48-750H
HWG48-1000H
150
151
COMMERCIAL STORAGE TANKS
STANDARD JACKETED STORAGE
TANKS
TJ-80A
TJ-80A
3/4" NPT
(ANODE )
3/4" NPT
(ANODE )
1" NPT
TJ-80A
2" NPT
2" ASME INSPECTION
OPENING (PLUGGED)
26 1/2"
Horizontal or Vertical Mounting
Options Available
2" NPT
FRONT & REAR
2" NPT
FRONT & REAR
2" NPT
FRONT & REAR
ASME PLATE
UNDER COVE R
ASME PLATE
UNDER COVE R
54 7/8"
54 7/8"
42 3/4"
3/4" NPT
REAR
32 1/4"
54 7/8"
42 3/4"
32 1/4"
Cement or Epoxy Linings Available
ASME Construction
3/4" NPT
REAR
TJV-120M
2" NPT
FRONT & REAR
2" NPT
FRONT & REAR
1" NPT
FRONT
2" NPT
3/4" NPT
(ANODE )
3/4" NPT
(ANODE )
TJ-80A
42 1/4"
15"
2" NPT
FRONT
1" NPT
FRONT
1" NPT
FRONT
2" NPT
FRONT
2" NPT
FRONT
2" NPT
FRONT
42 1/4"
4 1/8"
4 1/8"
54 7/8"
26 1/2"
3/4" NPT 19 1/2"
(ANODES)
3/4" NPT
11" 9 3/4"
FRONT
21 1/4"
2" NPT
9 3/4"
FRONT & REAR
2" ASME INSPECTION
2" NPT
OPENING (PLUGGED)
64"
3/4" NPT
TJV120M Jacketed-Vertical Only**
TJ80A Jacketed-Vertical Only***
TJV-120A***
TJV-200M (ASME)**
63
62
54-7/8
61-3/4
77
25-1/4
29-3/8
26-1/2
28
32
236
320
369
411
560
Plant of Manufacture:
*Renton, Washington only
**McBee, South Carolina only
***Both McBee, South Carolina and Renton, Washington
51 1/4"
7/8"
21
17 3/4"
47"
109 3/4"
3/4"
2" ASME INSPECTION
OPENING (PLUGGED)
16"
7"
2" NPT
2" ASME INSPECTION
2" ASME INSPECTION
OPENING (PLUGGED)
32 "
OPENING
(PLUGGED)
3 3/4"
1" NPT
3/4" NPT
3/4" NPT
)
77(ANODE
"
64"
80
119
80
119
175
63"
TJ
TJV-200M
2" NPT
77 "
Approx.
Shipping
Weight (lbs)
44 1/2"
17 3/4"
10 3/4"
TJV-120M
1" NPT
Diameter
(Inches)
2" NPT FRONT
3/4" NPT
50 1/2"
2" NPT FRONT
& REAR
44 1/2"
61 3/4"
3/4" NPT
LOCA TED UNDER
50 1/2"
COVE
R
1" NPT
2" NPT
32 "
Overall
Length
(Inches)
2" ASME INSPECTION
OPENING (PLUGGED)
61 ASME
3/4" PLATE
2" NPT FRONT
3/4" NPT
FRONT
REAR
2" ASME INSPECTION
OPENING (PLUGGED)
ASME PLATE
LOCA TED UNDER
COVE R
3/4" NPT
21 1/4"
2" NPT FRONT
(ANODES)
& REAR
9 3/4"
(ANODES)
NPT
323/4"
"
2" ASME INSPECTION
OPENING (PLUGGED)
28"
1" NPT
1" NPT
TJV-200M
3/4" NPT
REAR
3/4" NPT
2" NPT
FRONT & REAR
3/4" NPT
FRONT
Nominal
Gallon
Capacity
2
1-1/4" NPT
(ANODE )
1" NPT
28"
ASME PLATE
UNDER COVE R
3/4" NPT
50 1/2"
44 1/2"
2" ASME INSPECTION
OPENING (PLUGGED)
OPTIONAL
TJV-120A
2" ASME INSPECTION
28"
OPENING
(PLUGGED)
61 3/4"
4 1/8"
42 3/4"
FRONT & REAR 32 1/4"
3 1/2"
3/4" NPT
FRONT
2" NPT
FRONT & REAR
1" NPT
2" NPT
2" NPT
FRONT
11"
TJV-200M
2" NPT
3 1/2"
11"
• For complete warranty information, consult
3 1/2"
written warranty or go to hotwater.com.
15"
11"
3/4" NPT
REAR
1-1/4" NPT
(ANODE )
1" NPT
2" NPT
FRONT & REAR
54 1/4"
15"
3 3/4"
3/4" NPT
REAR
2" NPT
2" NPT
TJV-200M
54 1/4"
3 3/4"
TJV-120A
1" NPT
62"
5-Year Heat Exchanger and 1-Year Parts
Limited Warranty
7"
3/4" NPT
REAR
62"
42 1/4"
2" NPT
FRONT & REAR
16"
7"
29 3/8"
29 3/8"
54 1/4"
3/4" NPT
FRONT
47"
TJV-120A
2" NPT
3/4" NPT
(ANODE )
62"
47"
TJV-120M
29 3/8"
2" NPT
FRONT
51 7/8"
16"
16"
2" ASME INSPECTION
2" ASME INSPECTION
3/4" NPT 7"
OPENING (PLUGGED)
OPENING (PLUGGED)
REAR
3/4" NPT
(ANODE )
Meets R12.5 Minimum Thermal
Insulation Requirements of the U.S.
Department of Energy and Current
Edition of ASHRAE/IESNA 90.1
63"
3/4" NPT
FRONT
51 7/8"
3 3/4"
TJV-120M
lack Steel, Stainless and SiliconB
Bronze Tank Constructions Available
TJ80S Jacketed-Vertical Only**
3/4" NPT
REAR
3/4" NPT
REAR
63"
3/4" NPT
FRONT
3/4" NPT
REAR
2" NPT
Model Number
2" NPT
FRONT & REAR
3/4" NPT 51 7/8"
47"
FRONT
2" ASME INSPECTION
OPENING (PLUGGED)
25 1/4"
2" NPT
FRONT & REAR
3/4" NPT
REAR
19 1/2"
11" 9 3/4"
2" NPT
FRONT & REAR
2" NPT
FRONT & REAR
25 1/4"
3/4" NPT
REAR
63"
32 1/4"
19 1/2"
11" 9 3/4"
3/4" NPT
FRONT
19 1/2"
11" 9 3/4"
42 3/4"
3/4" NPT
(ANODE )
3/4" NPT
(ANODE )
2" ASME INSPECTION
OPENING (PLUGGED)
25 1/4"
ASME PLATE
UNDER COVE R
High-Density, Fiberglass Insulated
Jackets or Bare Steel Tanks
Anodic Protection
2" NPT
2" ASME INSPECTION
26 1/2"
OPENING (PLUGGED)
26 1/2"
TJ-80S
2" NPT
2" NPT
1" NPT
2" NPT
Glasslined per ASME, HLW Procedures
TJ-80S
TJ-80S
3/4" NPT1" NPT
(ANODE )
3/4" NPT
3/4" NPT
(ANODES)
2" NPT
2" NPT
ASME RATING PLATE AND
HAND HOLE LOCATED
UNDER COVER
ASME RATING PLATE AND
HAND HOLE LOCATED
UNDER COVER
1" NPT
2" NPT
77 "
2" ASME INSPECTION 17 1/4"
17 1/4" 17 1/4"
12 12
1/4"
12 1/4"
1/4" OPENING (PLUGGED)
17 1/4" 29 3/8"
64"
ASME RATING PLATE AND
12 1/4"
HAND HOLE LOCATED
UNDER COVER
17 1/4"
12 1/4"
17 1/4"
12 1/4"
1" NPT
FRONT
2" NPT
32 "
2" NPT
FRONT
1" NPT
62"
54 1/4"
2" NPT
FRONT
42 1/4"
77 "
3/4" NPT
61 3/4"
3/4" NPT
2" NPT
50 1/2"
44 1/2"
ASME RATING PLATE AND
HAND HOLE LOCATED
UNDER COVER
21 1/4"
TJV-200M
64"
15"
11"
3/4" NPT
(ANODES)
4 1/8"
3 1/2"
9 3/4"
2" NPT
FRONT & REAR
17 1/4"
12 1/4"
17 1/4"
12 1/4"
3/4" NPT
FRONT
2" ASME INSPECTION
OPENING (PLUGGED)
2" NPT
32 "
1" NPT
3/4" NPT
2" NPT
77 "
64"
152
17 1/4"
12 1/4"
ASME RATING PLATE AND
HAND HOLE LOCATED
UNDER COVER
17 1/4"
12 1/4"
153
COMMERCIAL STORAGE TANKS
CUSTOM-LINE FACTORY JACKETED
& INSULATED STORAGE TANKS
Glasslined per ASME, HLW Procedures
Horizontal or Vertical Mounting
Options Available
G
G
I*
E
High-Density, Fiberglass Insulated
Jackets or Bare Steel Tanks
I
D
A
3/4"
Cement or Epoxy Linings Available
1"
ASME Construction
G
G
Anodic Protection
B
C
F
lack Steel, Stainless and SiliconB
Bronze Tank Constructions Available
H
*Note: These connections are not for piping connections.
They are the anode locations and also serve as the required
ASME 2” inspection openings.
H
STORAGE TANK SELECTION
Meets R12.5 Minimum Thermal
Insulation Requirements of the U.S.
Department of Energy and Current
Edition of ASHRAE/IESNA 90.1
OPTIONAL
G
I*
E-NPT
E-NPT
I*
I*
1" NPT
3/4" NPT
D
B
D
I
E-NPT
E-NPT
5-Year Limited Tank Warranty
E-NPT
A
• For complete warranty information, consult
written warranty or go to hotwater.com.
3/4" NPT
F
J
2"
PLUG
E
H
*Note: These connections are not for piping
connections. They are the anode locations and also
serve as the required ASME 2” inspection openings.
H
C
Model
Number
& Gallon
Capacity
TJV-140
TJV-200
TJV-250
TJV-350
TJV-400
TJVT-500
TJV-500
TJV-750
TJV-1000
154
Dimensions in Inches
A
B
87
83
96
97
105
100
84
116
150
30
36
36
42
42
48
54
54
54
C
D
E
F
21-1/2 51
8 1-1/2
22
45 10 1-1/2
22
58 10 1-1/2
24-1/2 54 14 1-1/2
24-1/2 61 14 1-1/2
27
52 16 1-1/2
27-3/4 33-1/4 18 1-1/2
27-3/4 65-1/2 18 1-1/2
27-3/4 97-1/2 18 1-1/2
G
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
3
3
3
3
H
“I” ASME
Inspection
Openings
6-3/8
2
7-3/4
2
7-3/4
2
9-1/2
2
9-1/2
2
11-5/16 12 X 16
12-3/4 12 X 16
12-3/4 12 X 16
12-3/4 12 X 16
G
Model
Number
& Gallon
Capacity
Dimensions in Inches
A
B
41
41
TJH-350
47
TJH-400
47
TJHT-500 53
TJH-500
59
TJH-750
59
TJH-1000 59
36
36
42
42
48
54
54
54
TJH-200
TJH-250
C
D
77 16
90 15
93 17-1/2
99 17-1/2
94 21
79 22-3/4
111 22-3/4
143 22-3/4
E
F
2-1/2
2-1/2
2-1/2
2-1/2
3
3
3
3
11
11
10
10
11
12
12
11
G
H
“I” ASME
Inspection
Openings
J
23
16
2
1-1/2
23 22-1/2
2
1-1/2
26 22-1/2
2
1-1/2
26
26
2
1-1/2
29 19-1/2 12 X 16 1-1/2
32
11 12 X 16 1-1/2
32
27 12 X 16 1-1/2
32
43 12 X 16 1-1/2
155
COMMERCIAL STORAGE TANKS
UNINSULATED STANDARD STOCK
BARE STORAGE TANKS
Model Number
T-80 STD
T-120 STD
T-200 STD
Glasslined per ASME, HLW Procedures
T-350 STD
Horizontal or Vertical Mounting
Options Available
T-200 ASME
High-Density, Fiberglass Insulated
Jackets or Bare Steel Tanks
T-325 ASME
T-250 ASME
Cement or Epoxy Linings Available
OPTIONAL
T-140 ASME
T-350 ASME
T-400 ASME
TN-500 ASME
ASME Construction
T-500 ASME
Anodic Protection
T-1000 ASME
lack Steel, Stainless and SiliconB
Bronze Tank Constructions Available
Model Number
T-750 ASME
T-80 STD
Meets R12.5 Minimum Thermal
Insulation Requirements of the U.S.
Department of Energy and Current
Edition of ASHRAE/IESNA 90.1
T-120 STD
5-Year Limited Tank Warranty
T-200 ASME
• For complete warranty information, consult
written warranty or go to hotwater.com.
T-200 STD
T-350 STD
T-140 ASME
T-250 ASME
T-325 ASME
T-350 ASME
T-400 ASME
TN-500 ASME
T-500 ASME
T-750 ASME
T-1000 ASME
Model Number
T-80 STD
T-120 STD
T-200 STD
T-350 STD
2” ASME INSPECTION/ANODE OPENING
2” ASME
INSPECTION/ANODE OPENING
(ON 36” DIAMETER
AND BELOW)
(ON 36” DIAMETER AND BELOW)
12”x 16” ASME INSPECTION
OPENING (ON 42” DIAMETER
AND ABOVE)
12”x 16” ASME INSPECTION
OPENING (ON 42” DIAMETER
AND ABOVE)
T-140 ASME
T-200 ASME
T-250 ASME
T-325 ASME
T-350 ASME
T-400 ASME
TN-500 ASME
T-500 ASME
T-750 ASME
T-1000 ASME
156
Gallon
Capacity
Overall Dimensions in
Inches
Approx. Shipping
Weight (lbs)
80
119
200
350
140
200
250
325
350
400
500
500
750
1000
20 X 62-1/8
24-1/4 X 65
30 X 72
36 X 88
24 X 76-1/4
30 X 72
30 X 84
34 X 84
36 X 88
36 X 97
42 X 89
48 X 74
48 X 106
48 X 138
170
287
460
670
400
460
505
600
670
775
815
950
1290
1655
Dimensions in Inches
A
B
C
D
E
F
20
24-1/4
30
36
24
30
30
34
36
36
42
48
48
48
61-1/2
64-3/8
70-3/4
86
75
70-3/4
84
84
86
96
88
72-3/4
105
136
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
3
3
3
3
n/a
n/a
10
14
8
10
10
14
14
14
16
18
18
18
7
7
13
16
12
13
13-1/4
16
16
16
18
18
19-3/4
19-3/4
2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
2-1/2
3
3
3
3
G
H
J
K
N
P
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
46-1/4
34-1/2
28-1/2
31-1/2
27-1/2
28-1/2
28-1/2
28-3/4
31-1/2
31-1/2
33-1/2
32-3/4
32-3/4
32-3/4
16
15-1/2
19-1/2
20-1/4
18-1/2
19-1/2
19-1/2
19-3/4
20-1/4
20-1/4
24-1/2
26-3/4
26-3/4
26-3/4
3-1/2
10-1/2
13
16
12
13
13
13-3/4
16
16
18
19-3/4
19-3/4
19-3/4
3-1/4
3-1/2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4-1/8
4
4
4
4
4
5
4
4
5
6
6
6
Dimensions in Inches
157
COMMERCIAL STORAGE TANKS
HEAVY-DUTY LARGE VOLUME STORAGE
TANKS MODEL HD CUSTOM BUILT
Glasslined per ASME, HLW Procedures
Horizontal or Vertical Mounting Options
Available
High-Density, Fiberglass Insulated
Jackets or Bare Steel Tanks
Cement or Epoxy Linings Available
ASME Construction
Anodic Protection
lack Steel, Stainless and Silicon-Bronze
B
Tank Constructions Available
OPTIONAL
Model
Number
HD20-80
HD20-100
HD24-125
HD24-140
HD24-175
HD30-175
HD30-200
HD30-250
HD30-300
HD36-250
HD36-300
HD36-350
HD36-400
Meets R12.5 Minimum Thermal
Insulation Requirements of the U.S.
Department of Energy and Current
Edition of ASHRAE/IESNA 90.1
HD36-500
5-Year Limited Tank Warranty
HD42-600
• For complete warranty information, consult written
warranty or go to hotwater.com
HD42-375
HD42-450
HD42-500
HD42-700
HD42-800
HD48-500
HD48-600
HD48-700
HD48-750
HD48-900
HD48-1000
HD48-1250
HD48-1500
HD54-650
HD54-750
HD54-900
HD54-1000
HD54-1250
HD54-1500
HD54-1800
HD60-800
HD60-1000
HD60-1250
HD60-1500
HD60-1750
Shipping Weight (lbs.)
Nominal
Gallon
Capacity
Dimensions
Diameter x O.A.
Length (Inches)
Black
Steel
80
100
125
140
175
175
200
250
300
250
300
350
400
500
375
450
500
600
700
800
500
600
700
750
900
1,000
1,250
1,500
650
750
900
1,000
1,250
1,500
1,800
800
1,000
1,250
1,500
1,750
20 x 60
20 x 72
24 x 66
24 x 75
24 x 90
30 x 60
30 x 71
30 x 84
30 x 99
36 x 60
36 x 71
36 x 86
36 x 93
36 x 122
42 x 67
42 x 79
42 x 88
42 x 103
42 x 119
42 x 134
48 x 73
48 x 81
48 x 93
48 x 105
48 x 117
48 x 137
48 x 159
48 x 190
54 x 71
54 x 81
54 x 95
54 x 105
54 x 129
54 x 153
54 x 181
60 x 72
60 x 88
60 x 107
60 x 126
60 x 146
210
294
420
438
489
575
657
740
803
873
998
1,122
1,198
1,445
1,105
1,260
1,415
1,574
1,965
2,008
1,680
1,878
2,077
2,300
2,499
2,697
3,292
3,912
2,200
2,461
2,752
3,010
3,531
4,080
4,861
2,324
2,758
3,367
3,657
4,166
Glasslined
Cement
Epoxy
210
294
366
422
494
469
505
567
654
521
613
682
727
869
855
946
991
1,097
1,188
1,399
1,072
1,231
1,365
1,455
1,633
1,811
2,157
2,425
1,239
1,403
1,566
1,730
2,055
2,381
2,870
1,769
2,061
2,491
2,679
3,126
–
–
–
–
–
870
990
1,109
1,238
984
1,121
1,260
1,340
1,616
1,299
1,480
1,679
1,885
2,202
2,451
1,750
1,984
2,216
2,468
2,715
3,023
3,639
4,337
2,061
2,327
2,613
2,936
3,408
3,959
4,756
2,509
3,011
3,706
4,101
4,712
Line drawing and dimensions on the following page.
158
159
COMMERCIAL STORAGE TANKS
HEAVY-DUTY LARGE VOLUME STORAGE
TANKS MODEL HD CUSTOM BUILT
CUSTOM-LINE STORAGE TANKS (20” THRU 96” DIA. TANKS)
(CONTINUED)
OVERALL
A
B
E
THREADED LEG SOCKET
"C"
A
A
ASME PLATE
Model
Number
HD60-2000
HD66-1000
HD66-1500
HD66-2000
HD66-2500
HD72-2500
HD72-3000
HD72-3500
HD72-4000
HD84-4000
HD84-5000
HD84-6000
HD84-8000
HD96-7500
HD96-10000
HD96-12500
Nominal
Gallon
Capacity
2,000
1,000
1,500
2,000
2,500
2500
3,000
3,500
4,000
4,000
5,000
6,000
8,000
7,500
10,000
12,500
Dimensions
Diameter x OAL
(Inches)
60 x 165
66 x 75
66 x 107
66 x 139
66 x 171
72 x 147
72 x 174
72 x 201
72 x 228
84 x 173
84 x 212
84 x 252
84 x 330
96 x 244
96 x 319
96 x 395
A
Shipping Weight (lbs)
A
Black
Steel
Glasslined
Epoxy
Cement
4,844
2,760
3,886
5,010
6,101
6,224
7,116
8,493
9,831
9,508
11,865
13,599
17,737
15,843
20,628
24,590
3,505
1,929
2,675
3,422
4,170
4,126
4,669
5,212
6,027
6,348
7,871
9,012
11,674
11,711
15,261
18,303
5,432
2,808
4,011
5,184
6,388
5,800
6,653
7,943
9,238
9,093
11,354
13,063
17,070
16,090
20,950
24,892
A
A
A
B
B
A
A
A
A
NOTE:
1) 54” DIAMETER AND LARGER TANKS MUST BE ORDERED WITH ANGLE LEGS RATHER THAN THREADED LEG SOCKETS FOR VERTICAL INSTALLATIONS.
2) SPECIFY FOR HORIZONTAL OR VERTICAL INSTALLATION.
3) NO LEG SOCKETS PROVIDED ON HORIZONTAL TANKS.
2 each 2” ASME inspection openings are standard on tanks 36” diameter and below.
12”x16” ASME inspection openings are standard on tanks with 42” diameters and above.
CUSTOM-LINE STORAGE TANKS (20” THRU 96” DIA. TANKS)
OVERALL
A
1-1/4" CONTROL
OPENING
B
E
A
ASME PLATE
A
A
A
A
A
B
A
A
B
A
A
T&P VALVE
OPENING
A
A
B
NOTE:
1) ADD SUFFIX “ES” FOR SINGLE - WALL OR “ED” FOR DOUBLE - WALL TO MODEL NUMBER
WHEN EQUIPPED WITH A TUBE TANK HEATER (i.e.: HD-36-350ES).
2) SPECIFY FOR HORIZONTAL OR VERTICAL INSTALLATION.
3) NO LEG SOCKETS PROVIDED ON HORIZONTAL TANKS.
A
A
A
A
OVERALL
ASME PLATE
ALL DIMENSIONS IN INCHES
B
DIMENSION CHART
DIMENSION
A
B
C
D
E
E
20
2
3/4
1 1/2
6
3/4
24 THRU 36
2 1/2
3/4
2 1/2
8
1
42 AND 48
3
54 THRU 96
3
3/4
3/4
3
10
3
1
10
1
A
B
D
A
THREADED LEG SOCKET
"C"
Tank Saddles
A.O.Smith
Tank
A
Part Number Diameter
P2-2600-20
B
P2-2600-24
P2-2600-30
P2-2600-36
P2-2600-42
P2-2600-48
5’
(NOM.)
A
P2-2600-54
P2-2600-60
P2-2600-66
P2-2600-72
P2-2600-84
P2-2600-96
160
20
24
30
36
42
48
54
60
66
72
84
96
22
26
32
38
44
50
56
62
58
74
86
98
B
6
6
6
6
6
6
8
8
8
10
10
10
161
COMMERCIAL WATER HEATER
AC-U-TEMP COMPLETE HOT WATER
SYSTEMS
Standard Tank Sizes from 80 to
1000-Gallons
Ac-U-Temp System Eliminates
Costly Field Errors
Simplifies Installation
Standard Ac-U-Tanks are Factory
Jacketed and Insulated
All Systems are Built to Order
Multi-Heater Systems for 50%100%
Back-Up
Multi-Tank Systems Available
Superior I-Beam Skid
Factory Hydrostatic and Fire-Tested
Before Shipping
ASME Relief Valve 125#
Tank Temperature Sensor
Tank Thermometer
Isolation Valves
Custom Tank Sizes to 10,000
Gallons
5-Year Limited Heat Exchanger
Warranty and 5-Year Limited Tank
Warranty
• For complete warranty information, consult
written warranty or go to hotwater.com.
INSTANTANEOUS
SEMI-INSTANTANEOUS HWI
WATER HEATERS
A. O. Smith’s HWI Models are
Available for Operation with Steam
or Boiler Water as the Energy
Source. They are Factory Assembled
with Components Sized, Piped
and Checked at the Factory Before
Shipment. HWI Models are All
Space Saving Vertical Models.
Code Listing-the System Will
Employ an ASME ”U” Code Shell.
Fitted with an ASME “U” Code
3/4” Diameter Copper Tube Heat
Exchanger.
Integral Pump-the HWI System
Will Employ an Integral Bronze
Circulator Pump.
Steam Units - Steam Trim Consists
of Temperature Control Valve, Inlet
and Auxiliary Steam Traps, Inlet and
Auxiliary Strainers, Steam Pressure
Gauge with Siphon, Vacuum
Breaker and Air Vent.
oiler Units-Boiler Water Trim
B
Includes Temperature Control Valve
and Boiler Water Temperature
Gauge.
Control Features
• Single Point Wiring – Single 120V
Connection, Controls Including Integral
Circulation
• On/Off Switch-Allows Local On/Off for
Service
• Temperature Readout – LED readout of
water temperature
• PID Temperature Control – Modulates
electrical control valve
• High Temperature Limit – Closes main valve
under over temperature condition
• Remote Temperature Signal
• 2-Wire RS485 – Communication (MODBUS
or ASCII)
162
163
A. O. Smith | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
800.527.1953 | hotwater.com