Screw Pumps Series SM - Colfax Fluid Handling

Transcription

Screw Pumps Series SM - Colfax Fluid Handling
ALLWEILER
Screw Pumps
Series SM
SMF
SMH
Application
For handling lubricating fluids. The fluids to be pumped must
not contain any abrasive substances nor chemically attack the
pump materials.
Main fields of application
Fuel oil firing/energy engineering:
For handling light and heavy fuel oils as well as residual and
waste oils, e.g. as fuel oil, transfer, fuelling, ring-conduit, burneroperation and injection pumps (gas turbines).
Hydraulics:
For booster and/or pumping hydraulic oils on mineral-oil basis
or hydraulic lubricating liquids; e.g. as hydraulic pumps for lifts,
elevating platforms, pusher centrifuges, hydraulic presses,
forging hammers, bale presses, chip-board presses, winches,
hoists, variable-pitch propeller and rudder adjusting units,
hatch hydraulics, rolling mill and machine tool hydraulics.
General industrial engineering/machine/heavy machine industry:
For handling lubricating, cooling, coolant, sealing, regulating
and hydraulic oils, light and heavy fuel oils, Diesel oils, fuels and
thermal oils (cold), e.g. for steam, gas and water turbines as
sealing, regulating oil and jacking oil pumps, for compressors
as sealing and coolant oil pumps, for Diesel engines as cooling
oil as well as fuel pumps, for rolling mills as hydraulic pumps etc.
Marine/Offshore engineering:
For handling lubricating, cooling and hydraulic oils, light and
heavy fuel oils, crude oils as well as fuels.
Machine-tool industry:
For handling cutting, grinding, deep-hole drilling oils and oil-inwater emulsions as well as hydraulic oils.
Tank farms:
For handling all lubricating fluids such as greases, oils, paints,
fuels, polyols, isocyanates; e.g. as loading or unloading pumps.
Printing industry:
For handling gravure inks.
Chemical and petro-chemical as well as processing industry:
For handling all lubricating fluids such as oils (including crude
oils), greases, paint, lacquers, ointments, pastes, polyols, isocyanates, tar, bitumen, glycerin, glues, adhesive substances,
resins, paraffins, waxes, water glass and also as pipeline
pumps.
Paint/Iacquer industry:
For handling paints, lacquers, resins, oil varnish and linseed oils.
Washing/cleansing agent industry:
For handling oils, greases, soaps and additives.
Paper/pulp industry
For handling viscose and pulp.
Food industry:
For handling molasses, glucose, sirup and vegetable oils.
SMS
Design
Self-priming three-screw pump.
The hardened and ground spindles run in a replaceable casing
insert.
The axial thrust acting on the flanks of the screw threads is compensated by balance pistons which - with all three spindles are arranged in the delivery chamber.
The idler spindles are turned hydraulically. The thread flanks
merely transmit the torque resulting from the liquid friction and
are consequently practically free of stress and not subject to
any wear.
A groove ball bearing lubricated by the fluid to be pumped (with
internal bearing design) respectively an external, grease lubricated groove ball bearing serves for fixing the driving spindle.
A stuffing box or two shaft sealing rings or a maintenance-free
unbalanced mechanical seal as required is used as shaft
sealing. By means of a return pipe, the sealing chamber is
connected with the suction chamber. Therefore, irrespectively
of the delivery pressure, only the suction/inlet pressure
always becomes effective at the shaft sealing.
Function
Owing to a special profiling of the flanks of the screw threads,
the three spindles form sealed chambers, the contents of which
are axially and completely continuously shifted from the suction to the delivery side of the pump. There is no turbulence
despite the rotational movement, and squeezing stresses are
avoided by the constant volume in the chambers.
Noise/pulsation
The structural design and mode of operation of the screw pump
ensure a very low noise level and a nearly pulsation-free delivery.
Performance data
A preliminary pump selection can be effected by means of the
Performance tables (pages 6 to 13) For the exact performance
data as a function of the viscosity of the fluid to be pumped and
the pump speed, please refer to the individual characteristics.
Speed of rotation
Based on the small dimensions of the rotating screw spindles
and according to pump size and design rotational speeds up to
11 000 1/min are possible. With very high speeds respectively
for determining the speed limit the suction/inlet pressure conditions, the design of the shaft sealing and of the bearing as well
as the running speed of the thread flanks have to be considered.
1
Series SM...ER..
ALLWEILER
Temperature and pressure limits
admissible temperature of fluid to be pumped
with stuffing box, design U2 and KA2
with shaft sealing rings, design U3 and U4
with mechanical seal, design U
design D
design E
200°C
80°C
150°C c
80°C
80-150°C c
admissible suction lift
see NPSH values, page 5
admissible pump outlet pressure c
with pump casing in c.i. (GG-25)
in s.g.c.i. (GGG-40)
in fabricated steel
55 bar
90/100 bar e
120 bar
admissible supply pressure
with stuffing box, design U2 and KA2
with shaft sealing rings, design U3 and U4
with unbalanced mechanical seal
design U…, D…and E…
3,0 bar f
1,5 bar f
7,0 bar f
c with higher temperatures inquiry of our works necessary
d for the attainable delivery pressure as a function of viscosity and
speed please refer to the individual characteristics
For delivery pressures up to 250 bar please refer to series VH
(pamphlet VM 537 GB/ )
e 90 bar with pump sizes 280 to 1300 100 bar with pump sizes 40 to 210
f with higher supply pressures inquiry at our works necessary
The pump sizes 1700 and 2200 as well as all pump sizes with
outlet pressure exceeding 90/100 bar will be supplied in fabricated steel design. Dimension and sectional drawings are not
included in this pamphlet and must be demanded separately.
An incorporated control valve serves for a slight excess pressure within the area of the shaft sealing As a result here of,
during suction operation, air intake through the shaft sealing is
avoided an dry operation of the shaft sealing prevented The
design KA2 has no control valve and therefore should not be
used for suction operation
j Special mechanical seals and/or other material designs upon inquiry
Bearing
In an internal groove ball bearing
Design U…:
the groove ball bearing is lubricated by the
fluid to be pumped
In an external, grease lubricated groove ball bearing
Design D, KA:
no grease nipple, groove ball bearing in closed design with lifetime grease filing
Design E…:
with grease nipple A grease volume control
(labyrinth ring) prevents overgreasing of the
bearing and thus excessive heating up to
the bearing
Branch position/flanges
SMH,SMF,SMS: suction and delivery branch arranged on
centerline of pump and opposed out-of-line
The sense of flow may be changed without
alteration of sense of rotation by turning the
pump casing by 180°
Flanges with all designs
Suction side:
PN 16 according to DIN EN 1092-2
Delivery side:
PN 100 according to DIN 2547
Shaft sealing
Pump size
Stuffing
box g
Shaft seal
rings h
with … bearing
internal external
U2
KA2
SM
40... 2200
X
X
2 pcs
U3
X
Mechanical
seal i
with … bearing
3 pcs inter
external
U4
U...
D...
E...
X
X
X
X
Heating
For heating of pump, for instance when pumping heavy fuel oil
or other pumping liquids which solidify when getting cool, the
following heating devices are available.
Series
electrical
g with graphite incorporated PTFE packing
h made of NBR (buna N) resp FPM (Viton) (Viton at surplus price)
i uncooled maintenance free mechanical seal of the unbalanced type
Materials… 12 .1 (BRVGG) j
Rotary seal ring:
Carbon, resin-impregnated
Stationary seal ring: Ni Resist
Auxiliary sealings:
FPM (Viton)
Spring:
CrNiMo steel
Metal parts:
CrNiMo steel
Material
Part-No
1
2
3
4
4
5
5
6
7
8
9
9
12
13
Heating
with steam or heat conveyor
heating
elements
heating
cover
X
X
X
X
X
SMH
SMF
SMS
heating
cartridges
jacketed
casing
X
X
X
X
k Pumps with jacketed casing can only be supplied in fabricated steel
design (special technical documentation)
For further details of pump heating please refer to page 26
Material design
Denomination
Pump casing
Pump casing insert
Pump cover, drive side
Pump cover, non-drive side
Round pump foot (only with series SMS)
Bearing housing (only with external bearing)
Shaft sealing housing (only with internal bearing)
Pump foot
Pump casing cover
Balance bush
Seal cover
Gland (only with design U2 and KA2)
Driving spindle
Idler spindle
W2
c.i. (GG-25)
silafont
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
silafont
c.i. (GG-25)
c.i. (GG-25)
nitride steel
nitride steel
W3
s.g.c.i. (GGG-40)
silafont
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
c.i. (GG-25)
silafont
c.i. (GG-25)
c.i. (GG-25)
nitride steel
nitride steel
W12 l
fabricated steel
silafont
c.i. (GG-25)
fabricated steel
fabricated steel
c.i. (GG-25)
c.i. (GG-25)
fabricated steel
c.i. (GG-25)
silafont
c.i. (GG-25)
c.i. (GG-25)
nitride steel
nitride steel
l For pumps in fabricated steel design (pump sizes 1700 and 2200 as well as pumps with outlet pressures exceeding 90/100 bar and/or
because of customers specific demands) separate technical documentation is available
2
VM 618 GB/02.00
Series SM...ER..
ALLWEILER
Pressure relief valves
All pumps can be supplied with built-on pressure relief valve
For allocation, dimensions and connections please refer to
page 27.
Valve characteristics and sectional drawings are not included
within this pamphlet and must be demanded separately.
In case pumps without built-on pressure relief valve are required, an overload protection must be provided in the control
System or as a pipeline pressure relief valve.
For allocation, dimensions and connections of pressure relief
valves for pipeline Installation please refer to page 28.
Shaft coupling and protection against accidental contact
Shaft coupling according to DIN 740.
A protection according to DIN 24295 against accidental contact also is supplied as soon as the scope of supply includes
pump, base plate and shaft coupling or when an intermediate
bracket, respectively bracket with feet is included in the delivery volume.
Drive
The pumps will be coupled either directly (Series SMH) or by
means of an intermediate bracket (Series SMS), respectively of
a bracket with feet for floor or wall mounting (Series SMF) with
electric motors of the most varied kinds or with other driving
engines.
In most cases, surface cooled, three phase AC Short Circuit
motors, construction B3 or V1 are provided, enclosure IP54
according to IEC Standard, class B insulation, motor windings
for 400 VA, 50 or 60 Hz.
3
Series SM...ER..
ALLWEILER
Unit-assembly principle
Three-screw pumps, SM series.
Same delivery elements with different types of casing construction.
Pump casing insert + Screw spindle set
c For series SMFBA refer to pamphlet VM 664 GB/
Performance survey
For nominal pump outputs not covered by the type SM further pump series of single entry three-screw pumps are available according to the following survey (stated performances refer to 50 Hz speeds).
4
VM 618 GB/02.00
Series SM...ER..
ALLWEILER
NPSH req. (m)
The values as indicated apply to airless fluids to be pumped (a safety allowances of 0.5 m is already included) In case of fluids to be
pumped with air pockets (unsolved air), either the pump must be adapted or allowances on the stated NPSH values are necessary
For these purposes, by all means inquire at our works.
For exact NPSH values in dependence of the viscosity (also for other viscosities than those mentioned below) and of the pump
rotational speed (also for other speeds of rotation than those mentioned below), please refer to the individual NPSH graphs
Pump
size
Kinematic viscosity v
2
40 mm2/s
6 mm /s
Speed n [1/min]
SM...
380 mm2/s
Speed n [1/min]
Speed n [1/min]
1450
1750
2900
3500
1450
1750
2900
3500
1450
1750
2900
3500
m
m
m
m
m
m
m
m
m
m
m
m
40-38
40-46
80-36
80-42
80-46
120-42
120-46
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,5
3,3
4,5
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,3
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,1
3,8
3,0
3,0
3,0
3,0
3,0
3,0
3,1
3,8
4,6
3,7
4,8
6,3
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,8
3,0
3,0
3,0
3,0
3,0
3,4
3,6
4,5
3,0
3,0
3,0
3,0
4,4
5,4
5,8
7,6
210-40
210-46
3,0
3,0
3,0
3,0
3,0
3,8
3,6
5,0
3,0
3,0
3,0
3,0
3,2
4,5
4,2
6,0
3,0
3,0
3,0
3,5
5,2
7,5
7,0
c
280-43
280-46
3,0
3,0
3,0
3,0
3,7
4,5
4,8
6,1
3,0
3,0
3,0
3,0
4,3
5,3
5,8
7,5
3,0
3,3
3,6
4,1
7,3
c
c
c
440-40
440-46
3,0
3,0
3,0
3,0
3,8
5,7
5,2
8,1
3,0
3,0
3,0
3,2
4,6
6,9
6,4
c
3,1
3,8
3,8
5,0
7,8
c
c
c
660-40
660-46
3,0
3,0
3,0
3,4
5,1
7,5
7,2
-
3,0
3,1
3,0
3,9
6,1
c
8,7
-
3,6
4,6
4,7
6,5
c
c
c
-
940-42
940-46
3,0
3,0
3,1
3,4
6,8
c
-
3,0
3,5
3,6
4,6
8,0
c
-
4,4
5,6
5,8
7,9
c
c
-
1300-42
1300-46
3,0
3,4
3,6
4,6
8,3
-
-
3,3
4,0
4,2
5,4
c
-
-
5,2
7,6
7,2
c
c
-
-
1700-42
1700-46
3,2
3,4
4,3
5,4
-
-
3,8
4,6
5,0
6,6
-
-
6,1
7,9
8,5
c
-
-
2200-42
2200-46
3,7
4,2
4,9
6,3
-
-
4,4
5,3
6,0
7,6
-
-
7,3
c
c
c
-
-
c Inlet pressure necessary
5
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
l/min
P
kW
Q
l/min
P
kW
Q
l/min
P
kW
Q
l/min
P
kW
40-38
20
30
40
50
60
70
80
90
100
110
120
24,50
21,50
18,60
15,80
13,10
-
1,27
1,81
2,34
2,87
3,40
-
28,70
27,40
26,10
24,90
23,70
22,50
21,40
20,30
19,20
18,10
-
1,27
1,81
2,34
2,87
3,40
3,94
4,47
5,00
5,53
6,06
-
56,50
53,40
50,50
47,80
45,10
42,40
39,80
-
2,34
3,40
4,47
5,53
6,60
7,66
8,72
-
60,60
59,30
58,00
56,80
55,60
54,40
53,30
52,20
51,10
50,00
49,00
2,34
3,40
4,47
5,53
6,60
7,66
8,72
9,79
10,90
11,90
13,00
40-46
20
30
40
50
60
70
80
90
100
110
120
33,60
29,80
26,30
-
1,63
2,34
3,05
-
38,60
37,00
35,40
33,90
32,50
31,10
29,70
-
1,63
2,34
3,05
3,76
4,47
5,18
5,89
-
76,10
72,40
68,90
65,50
62,20
-
3,68
5,10
6,52
7,94
9,35
-
81,20
79,50
78,00
76,50
75,10
73,60
72,30
70,90
69,60
68,30
67,00
3,68
5,10
6,52
7,94
9,35
10,80
12,20
13,60
15,00
16,40
17,90
80-36
20
30
40
50
60
70
80
90
100
110
120
46,10
41,20
36,40
31,90
27,50
-
2,27
3,24
4,21
5,18
6,15
-
53,00
50,80
48,80
46,80
44,90
43,00
41,20
39,40
37,70
35,90
34,20
2,27
3,24
4,21
5,18
6,15
7,12
8,09
9,06
10,00
11,00
12,00
104,00
99,40
94,60
90,10
85,70
81,40
77,20
73,00
-
5,20
7,14
9,08
11,00
13,00
14,90
16,80
18,80
-
111,00
109,00
107,00
105,00
103,00
101,00
99,40
97,60
95,90
94,10
92,40
5,20
7,14
9,08
11,00
13,00
14,90
16,80
18,80
20,70
22,70
24,60
80-42
20
30
40
50
60
70
80
90
100
110
120
55,90
49,80
44,00
38,50
-
2,69
3,86
5,04
6,22
-
64,20
61,50
59,00
56,50
54,20
51,90
49,60
47,40
45,20
-
2,69
3,86
5,04
6,22
7,40
8,58
9,75
10,90
12,10
-
127,00
120,00
115,00
109,00
104,00
98,50
-
6,03
8,39
10,70
13,10
15,50
17,80
-
135,00
132,00
130,00
127,00
125,00
123,00
120,00
118,00
116,00
114,00
112,00
6,03
8,39
10,70
13,10
15,50
17,80
20,20
22,50
24,90
27,20
29,60
80-46
20
30
40
50
60
70
80
90
100
110
120
68,40
62,30
56,50
-
3,10
4,49
5,87
-
76,70
74,00
71,50
69,00
66,60
64,30
62,10
-
3,10
4,49
5,87
7,26
8,65
10,00
11,40
-
152,00
145,00
140,00
134,00
129,00
-
6,86
9,64
12,40
15,20
18,00
-
160,00
157,00
155,00
152,00
150,00
147,00
145,00
143,00
141,00
139,00
137,00
6,86
9,64
12,40
15,20
18,00
20,70
23,50
26,30
29,00
31,80
34,60
120-42
20
30
40
50
60
70
80
90
100
110
120
80,90
73,00
65,50
58,30
-
3,85
5,52
7,18
8,85
-
91,70
88,30
85,00
81,90
78,90
75,90
73,00
70,20
67,40
-
181,00
173,00
166,00
158,00
151,00
145,00
-
8,74
12,10
15,40
18,70
22,10
25,40
-
192,00
188,00
185,00
182,00
179,00
176,00
173,00
170,00
167,00
165,00
162,00
8,74
12,10
15,40
18,70
22,10
25,40
28,70
32,10
35,40
38,70
42,10
120-46
20
30
40
50
60
70
80
90
100
110
120
99,30
91,40
84,00
-
4,47
6,44
8,41
-
110,00
107,00
103,00
100,00
97,30
94,30
91,50
-
3,85
5,52
7,18
8,85
10,50
12,20
13,80
15,50
17,20
4,47
6,44
8,41
10,40
12,40
14,30
16,30
-
218,00
210,00
202,00
195,00
188,00
-
9,97
13,90
17,90
21,80
25,80
-
228,00
225,00
222,00
219,00
216,00
213,00
210,00
207,00
204,00
201,00
199,00
9,97
13,90
17,90
21,80
25,80
29,70
33,70
37,60
41,50
45,50
49,40
n = 1450 1/mm
2
v = 6 mm /s
n = 2900 1/min
2
v = 40 mm /s
2
v = 6 mm /s
2
v = 40 mm /s
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities than
those mentioned above) and the pump speed, please refer to the individual characteristics.
6
VM 618 GB/3.96 4000
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
1/min
P
kW
Q
1/min
P
kW
Q
l/min
P
kW
Q
l/min
P
kW
210-40
20
30
40
50
60
70
80
90
100
110
120
145,00
135,00
125,00
116,00
-
6,51
9,33
12,10
15,00
-
158,00
154,00
150,00
146,00
142,00
138,00
134,00
131,00
127,00
-
6,51
9,33
12,10
15,00
17,80
20,60
23,40
26,20
29,00
-
314,00
304,00
294,00
285,00
276,00
267,00
259,00
-
14,80
20,40
26,10
31,70
37,30
43,00
48,60
-
327,00
323,00
319,00
315,00
311,00
307,00
303,00
300,00
296,00
293,00
289,00
14,80
20,40
26,10
31,70
37,30
43,00
48,60
54,20
59,90
65,50
71,10
210-46
20
30
40
50
60
70
80
90
100
110
120
183,00
170,00
159,00
-
7,95
11,50
15,00
-
199,00
194,00
189,00
184,00
179,00
175,00
170,00
-
7,95
11,50
15,00
18,60
22,10
25,60
29,20
-
395,00
383,00
371,00
360,00
349,00
-
17,70
24,70
31,80
38,90
46,00
-
411,00
406,00
401,00
396,00
391,00
387,00
382,00
378,00
373,00
369,00
365,00
17,70
24,70
31,80
38,90
46,00
53,00
60,10
67,20
74,30
81,30
88,40
280-43
20
30
40
50
60
70
80
90
100
110
120
212,00
198,00
184,00
170,00
-
9,73
13,90
18,00
22,10
-
232,00
226,00
220,00
214,00
208,00
202,00
197,00
192,00
-
9,73
13,90
18,00
22,10
26,30
30,40
34,50
38,70
-
460,00
445,00
431,00
418,00
405,00
392,00
-
480,00
474,00
468,00
462,00
456,00
450,00
445,00
439,00
434,00
429,00
424,00
22,40
30,70
38,90
47,20
55,50
63,70
72,00
80,20
88,50
96,80
105,00
280-46
20
30
40
50
60
70
80
90
100
110
120
245,00
230,00
216,00
-
10,80
15,50
20,20
-
265,00
258,00
252,00
246,00
241,00
235,00
230,00
-
10,80
15,50
20,20
24,90
29,50
34,20
38,90
-
526,00
511,00
497,00
483,00
470,00
-
22,40
30,70
38,90
47,20
55,50
63,70
24,60
33,90
43,30
52,70
62,00
-
546,00
539,00
533,00
527,00
521,00
516,00
510,00
505,00
500,00
494,00
489,00
24,60
33,90
43,30
52,70
62,00
71,40
80,70
90,10
99,40
109,00
118,00
440-40
20
30
40
50
60
70
80
90
100
110
120
309,00
292,00
276,00
261,00
-
14,00
19,80
25,60
31,50
-
332,00
325,00
318,00
311,00
305,00
298,00
292,00
286,00
280,00
-
14,00
19,80
25,60
31,50
37,30
43,10
49,00
54,80
60,60
-
659,00
642,00
626,00
611,00
596,00
581,00
567,00
-
32,50
44,10
55,80
67,50
79,10
90,80
102,00
-
682,00
675,00
668,00
661,00
655,00
649,00
642,00
636.00
630 00
624,00
618,00
32,50
44,10
55,80
67,50
79,10
90,80
102,00
114,00
126,00
138,00
149,00
440-46
20
30
40
50
60
70
80
90
100
110
120
396,00
375,00
356,00
-
17,10
24,60
32,00
-
424,00
415,00
406,00
398,00
390,00
382,00
375,00
-
17,10
24,60
32,00
39,40
46,80
54,30
61,70
-
841,00
821,00
801,00
782,00
764,00
-
38,80
53,70
68,50
83,40
98,20
-
869,00
860,00
852,00
844,00
836,00
828,00
820,00
813,00
806,00
798,00
791,00
38,80
53,70
68,50
83,40
98,20
113,00
128,00
143,00
158,00
173,00
187,00
n = 1450 1/min
v = 6 mm2/s
n = 2900 1/min
v = 40 mm2/s
v = 6 mm2/s
v = 40 mm2/s
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities than those
mentioned above) and the pump speed, please refer to the individual characterstics.
VM 618 GB/3.96
4001
7
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [l/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
l/min
P
kW
Q
l/mm
P
kW
Q
l/min
P
kW
Q
l/min
P
kW
660-40
20
30
40
50
60
70
80
90
100
110
120
485,00
463,00
441,00
421,00
-
21,30
30,30
39,30
48,30
-
516,00
507,00
497,00
488,00
479,00
471,00
463,00
454,00
-
21,30
30,30
39,30
48,30
57,30
66,30
75,30
84,30
-
1026,00
1003,00
982,00
961,00
941,00
921,00
-
49,00
67,00
85,00
103,00
121,00
139,00
-
1057,00
1047,00
1038,00
1029,00
1020,00
1011,00
1003,00
995,00
987,00
979,00
971,00
49,00
67,00
85,00
103,00
121,00
139,00
157,00
175,00
193,00
211,00
229,00
660-46
20
30
40
50
60
70
80
90
100
110
120
598,00
571,00
545,00
-
25,40
36,50
47,60
-
636,00
624,00
613,00
602,00
591,00
580,00
-
25,40
36,50
47,60
58,70
69,80
80,80
-
1264,00
1236,00
1210,00
1185,00
1160,00
-
57,30
79,50
102,00
124,00
146,00
-
1301,00
1289,00
1278,00
1267,00
1256,00
1246,00
1236,00
1226,00
1216,00
1206,00
-
57,30
79,50
102,00
124,00
146,00
168,00
190,00
213,00
235,00
257,00
-
940-42
20
30
40
50
60
70
80
90
100
110
120
703,00
667,00
633,00
-
30,70
43,90
57,00
-
752,00
736,00
721,00
707,00
693,00
680,00
667,00
654,00
-
30,70
43,90
57,00
70,20
83,30
96,50
110,00
123,00
-
1492,00
1456,00
1423,00
1390,00
1358,00
1328,00
-
70,30
96,60
123,00
149,00
176,00
202,00
-
1541,00
1525,00
1511,00
1496,00
1483,00
1469,00
1456,00
1443,00
1431,00
1418,00
1406,00
70,30
96,60
123,00
149,00
176,00
202,00
228,00
254,00
281,00
307,00
333,00
940-46
20
30
40
50
60
70
80
90
100
110
120
861,00
825,00
791,00
-
36,00
51,80
67,60
-
909,00
894,00
879,00
865,00
851,00
838,00
-
36,00
51,80
67,60
83,30
99,10
115,00
-
1808,00
1772,00
1738,00
1706,00
1674,00
-
80,80
112,00
144,00
176,00
207,00
-
1857,00
1841,00
1826,00
1812,00
1798,00
1785,00
1772,00
1759,00
1746,00
1734,00
-
80,80
112,00
144,00
176,00
207,00
239,00
270,00
302,00
333,00
365,00
-
1300-42
20
30
40
50
60
70
80
90
100
110
120
1009,00
964,00
921,00
-
42,90
61,50
80,20
-
1070,00
1050,00
1032,00
1014,00
997,00
980,00
963,00
947,00
-
42,90
61,50
80,20
98,80
117,00
136,00
155,00
173,00
-
2126,00
2081,00
2039,00
1998,00
1958,00
1919,00
-
97,20
134,00
172,00
209,00
246,00
283,00
-
2187,00
2168,00
2149,00
2131,00
2114,00
2097,00
2081,00
2064,00
2048,00
2033,00
2017,00
97,20
134,00
172,00
209,00
246,00
283,00
321,00
358,00
395,00
432,00
470,00
1300-46
20
30
40
50
60
70
80
90
100
110
120
1191,00
1146,00
1103,00
-
49,00
70,60
92,30
-
1252,00
1232,00
1214,00
1196,00
1179,00
1162,00
-
49,00
70,60
92,30
114,00
136,00
157,00
-
n = 14501/min
v = 6 mm2/s
n = 2900 1/min
v = 40 mm2/s
v = 6 mm2/s
v = 40 mm2/s
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other
viscosities than those mentioned above) and the pump speed, please refer to the individual characteristics.
8
VM 618 GB/3.96
4002
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [l/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
n = 1450 1/min
2
v = 6 mm /s
n = 2900 1/min
2
v = 40 mm /s
1700-42
c
20
30
40
50
60
70
80
90
100
110
120
Q
l/min
1360,00
1304,00
1252,00
-
P
kW
57,10
82,00
107,00
-
Q
l/min
1435,00
1411,00
1388,00
1366,00
1345,00
1324,00
1304,00
1284,00
-
P
kW
57,10
82,00
107,00
132,00
1 57,00
1 82,00
206,00
231,00
-
1700-46
c
20
30
40
50
60
70
80
90
100
110
120
1595,00
1540,00
1488,00
-
65,00
93,80
123,00
-
1671,00
1647,00
1624,00
1602,00
1581,00
1560,00
-
65,00
93,80
1 23,00
151,00
180,00
209,00
-
2200-42
c
20
30
40
50
60
70
80
90
100
110
120
1784,00
1717,00
1654,00
-
74,40
107,00
139,00
-
1875,00
1846,00
1818,00
1792,00
1766,00
1741,00
1716,00
1692,00
-
74,40
107,00
1 39,00
1 72,00
204,00
237,00
269,00
301,00
-
2200-46
c
20
30
40
50
60
70
80
90
100
110
120
2083,00
2017,00
1953,00
-
84,40
122,00
159,00
-
2174,00
2145,00
2118,00
2091,00
2065,00
2040,00
-
84,40
122,00
1 59,00
197,00
234,00
271,00
-
2
2
v = 6 mm /s
Q
l/min
v = 40 mm /s
P
kW
Q
l/min
P
kW
e These pump sizes are only available in fabricated steel design (please see also remarks under temperature and pressure limits, page 2)
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other
viscosities than those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 618 GB/3.96
4003
9
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
20
30
40
50
60
70
80
90
100
110
120
Q
l/min
31,10
28,10
25,20
22,40
19,70
-
40-46
20
30
40
50
60
70
80
90
100
110
120
n = 1750 1/min
2
n = 3500 1/min
2
2
v = 6 mm /s
2
P
kW
1,49
2,14
2,78
3,42
44,06
-
v = 40 mm /s
Q
P
l/min
kW
35,30
1,49
34,00
2,14
32,70
2,78
31,50
3,42
30,30
4,06
29,10
4,71
28,00
5,35
26,90
5,99
25,80
6,63
24,70
7,27
23,70
7,92
Q
l/min
69,70
66,60
63,80
61,00
58,30
55,60
53,10
50,50
-
P
kW
2,78
4,06
5,35
6,63
7,92
9,20
10,50
11,80
-
Q
l/min
73,80
72,50
71,20
70,00
68,80
67,70
66,50
65,40
64,30
63,30
62,20
P
kW
2,78
4,06
5,35
6,63
7,92
9,20
10,50
11,80
13,10
14,30
15,60
42,40
38,70
35,10
31,70
-
2,02
2,87
3,73
4,59
-
47,40
45,80
44,20
42,70
41,30
39,90
38,50
37,10
-
2,02
2,87
3,73
4,59
5,44
6,30
7,16
8,01
-
93,70
90,00
86,50
83,10
79,80
76,60
-
4,65
6,36
8,07
9,79
11,50
13,20
-
98,80
97,20
95,60
94,10
92,70
91,30
89,90
88,50
87,20
85,90
84,60
4,65
6,36
8,07
9,79
11,50
13,20
14,90
16,60
18,30
20,10
21,80
80-36
20
30
40
50
60
70
80
90
100
110
120
58,20
53,20
48,50
43,90
39,50
35,20
-
2,82
3,99
5,16
6,33
7,50
8,68
-
65,00
62,90
60,80
58,90
56,90
55,10
53,30
51,50
49,70
48,00
46,30
2,82
3,99
5,16
6,33
7,50
8,68
9,85
11,00
12,20
13,40
14,50
128,00
123,00
119,00
114,00
110,00
105,00
101,00
97,10
-
6,61
8,95
11,30
13,60
16,00
18,30
20,70
23,00
-
135,00
133,00
131,00
129,00
127,00
125,00
123,00
122,00
120,00
118,00
117,00
6,61
8,95
11,30
13,60
16,00
18,30
20,70
23,00
25,30
27,70
30,00
80-42
20
30
40
50
60
70
80
90
100
110
120
70,50
64,40
58,70
53,10
47,70
-
3,32
4,75
6,17
7,59
9,01
-
78,80
76,10
73,60
71,20
68,80
66,50
64,20
62,00
59,80
57,70
-
3,32
4,75
6,17
7,59
9,01
10,40
11,90
13,30
14,70
16,10
-
156,00
150,00
144,00
138,00
133,00
128,00
123,00
-
7,61
10,50
13,30
16,10
19,00
21,80
24,70
-
164,00
161,00
159,00
156,00
154,00
152,00
150,00
147,00
145,00
143,00
141,00
7,61
10,50
13,30
16,10
19,00
21,80
24,70
27,50
30,40
33,20
36,00
80-46
20
30
40
50
60
70
80
90
100
110
120
85,60
79,50
73,70
68,10
-
3,83
5,50
7,17
8,84
-
93,90
91,20
88,70
86,20
83,80
81,50
79,30
77,10
-
3,83
5,50
7,17
8,84
10,50
12,20
13,90
15,50
-
186,00
180,00
174,00
169,00
163,00
158,00
-
8,61
12,00
15,30
18,60
22,00
25,30
-
194,00
192,00
189,00
187,00
184,00
182,00
180,00
177,00
175,00
173,00
171,00
8,61
12,00
15,30
18,60
22,00
25,30
28,70
32,00
35,40
38,70
42,10
120-42
20
30
40
50
60
70
80
90
100
110
120
102,00
93,70
86,20
79,00
72,00
-
4,78
6,79
8,80
10,80
12,80
-
112,00
109,00
106,00
103,00
99,60
96,60
93,70
90,90
88,10
85,30
-
4,78
6,79
8,80
10,80
12,80
14,80
16,80
18,90
20,90
22,90
-
222,00
214,00
207,00
200,00
193,00
186,00
179,00
-
11,10
15,10
19,10
23,10
27,20
31,20
35,20
-
233,00
230,00
226,00
223,00
220,00
217,00
214,00
212,00
209,00
206,00
203,00
11,10
15,10
19,10
23,10
27,20
31,20
35,20
39,20
43,20
47,30
51,30
120-46
20
30
40
50
60
70
80
90
100
110
120
124,00
116,00
108,00
101,00
-
5,52
7,90
10,30
12,70
-
135,00
131,00
128,00
125,00
122,00
119,00
116,00
113,00
-
5,52
7,90
10,30
12,70
15,00
17,40
19,80
22,20
-
267,00
259,00
251,00
244,00
237,00
230,00
-
12,60
17,30
22,10
26,80
31,60
36,40
-
277,00
274,00
271,00
268,00
265,00
262,00
259,00
256,00
253,00
250,00
248,00
12,60
17,30
22,10
26,80
31,60
36,40
41,10
45,90
50,70
55,40
60,20
40-38
v = 6 mm /s
v = 40 mm /s
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
10
VM 618 GB/3.96
4004
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [l/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
1/min
P
kW
Q
1/min
P
kW
Q
1/min
P
kW
Q
1/min
P
kW
210-40
20
30
40
50
60
70
80
90
100
110
120
180,00
170,00
160,00
151,00
142,00
-
8,08
11,50
14,90
18,30
21,70
-
193,00
189,00
185,00
181,00
177,00
173,00
169,00
166,00
162,00
159,00
-
8,08
11,50
14,90
18,30
21,70
25,10
28,50
31,90
35,30
38,70
-
384,00
374,00
364,00
355,00
346,00
337,00
329,00
321,00
-
18,70
25,50
32,30
39,10
45,90
52,70
59,50
66,30
-
397,00
393,00
389,00
385,00
381,00
377,00
373,00
370,00
366,00
363,00
359,00
18,70
25,50
32,30
39,10
45,90
52,70
59,50
66,30
73,10
79,90
86,70
210-46
20
30
40
50
60
70
80
90
100
110
120
227,00
214,00
203,00
192,00
-
9,82
14,10
18,40
22,60
-
243,00
238,00
233,00
228,00
223,00
218,00
214,00
210,00
-
9,82
14,10
18,40
22,60
26,90
31,20
35,40
39,70
-
483,00
471,00
459,00
448,00
437,00
427,00
-
22,20
30,70
39,30
47,80
56,40
64,90
-
499,00
494,00
489,00
484,00
479,00
475,00
470,00
466,00
461.00
457,00
453,00
22,20
30,70
39,30
47,80
56,40
64,90
73,40
82,00
90 50
99,00
108,00
280-43
20
30
40
50
60
70
80
90
100
110
120
263,00
249,00
235,00
221,00
-
12,10
17,10
22,10
27,10
-
283,00
277,00
271,00
265,00
259,00
254,00
248,00
243,00
238,00
-
12,10
17,10
22,10
27,10
32,10
37,00
42,00
47,00
52,00
-
563,00
548,00
534,00
521,00
508,00
495,00
482,00
-
28,50
38,50
48,50
58,40
68,40
78,40
88,30
-
583,00
576,00
570,00
564,00
558,00
553,00
547,00
542,00
537,00
532,00
526,00
28,50
38,50
48,50
58,40
68,40
78,40
88,30
98,30
108,00
118,00
128,00
280-46
20
30
40
50
60
70
80
90
100
110
120
303,00
288,00
274,00
261,00
-
13,40
19,10
24,70
30,40
-
323,00
317,00
310,00
305,00
299,00
293,00
288,00
282,00
-
13,30
19,10
24,70
30,40
36,00
41,70
47,30
52,90
-
642,00
627,00
613,00
600,00
587,00
574,00
-
31,10
42,40
53,70
65,00
76,30
87,60
-
662,00
655,00
649,00
643,00
637,00
632,00
626,00
621,00
616,00
611,00
605,00
31,10
42,40
53,70
65,00
76,30
87,60
98,90
110,00
121,00
133,00
144,00
440-40
20
30
40
50
60
70
80
90
100
110
120
381,00
365,00
348,00
333,00
318,00
-
17,40
24,40
31,50
38,50
45,60
-
405,00
397,00
390,00
384,00
377,00
371,00
365,00
358,00
352,00
347,00
-
17,40
24,40
31,50
38,50
45,60
52,60
59,70
66,70
73,70
80,80
-
804,00
787,00
771,00
756,00
741,00
726,00
712,00
698,00
-
41,50
55,50
69,60
83,70
97,80
112,00
126,00
140,00
-
827,00
820,00
813,00
806,00
800,00
793,00
787,00
781,00
775,00
769,00
763,00
41,50
55,50
69,60
83,70
97,80
112,00
126,00
140,00
154,00
168,00
182,00
440-46
20
30
40
50
60
70
80
90
100
110
120
488,00
467,00
448,00
429,00
-
21,20
30,20
39,20
48,10
-
516,00
507,00
499,00
490,00
482,00
475,00
467,00
460,00
-
21,20
30,20
39,20
48,10
57,10
66,10
75,00
84,00
-
1026,00
1005,00
986,00
967,00
949,00
931,00
-
49,10
67,10
85,00
103,00
121,00
139,00
-
1054,00
1045,00
1036,00
1028,00
1020,00
1012,00
1005,00
997,00
990,00
983,00
976,00
49,10
67,10
85,00
103,00
121,00
139,00
157,00
175,00
193,00
210,00
228,00
n = 1750 1/mm
v = 6 mm 2/s
n = 3500 1/min
v = 40 mm 2/s
v= 6 mm 2 /s
v = 40 mm 2/s
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 618 GB/3.96
4005
11
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
1/min
P
kW
660-40
20
30
40
50
60
70
80
90
100
110
120
597,00
575,00
553,00
533,00
-
26,50
37,30
48,20
59,10
-
628,00
618,00
609,00
600,00
591,00
583,00
574,00
566,00
558,00
-
26,50
37,30
48,20
59,10
69,90
80,80
91,70
103,00
113,00
-
660-46
20
30
40
50
60
70
80
90
100
110
120
736,00
708,00
682,00
-
31,50
44,90
58,20
-
774,00
762,00
750,00
739,00
729,00
718,00
708,00
-
31,50
44,90
58,20
71,60
85,00
98,40
112,00
-
940-42
20
30
40
50
60
70
80
90
100
110
120
866,00
830,00
797,00
764,00
-
38,20
54,10
69,90
85,80
-
915,00
899,00
885,00
870,00
857,00
843,00
830,00
817,00
-
38,20
54,10
69,90
85,80
102,00
118,00
133,00
149,00
-
940-46
20
30
40
50
60
70
80
90
100
110
120
1057,00
1021,00
987,00
-
44,50
63,60
82,60
-
1105,00
1090,00
1075,00
1061,00
1047,00
1034,00
1021,00
-
44,50
63,60
82,60
102,00
121,00
140,00
159,00
-
1300-42
20
30
40
50
60
70
80
90
100
110
120
1240,00
1195,00
1153,00
1112,00
-
53,20
75,70
98,20
121,00
-
1301,00
1282,00
1263,00
1245,00
1228,00
1211,00
1194,00
1178,00
-
53,20
75,70
98,20
121,00
143,00
166,00
188,00
211,00
-
1300-46
20
30
40
50
60
70
80
90
100
110
120
1459,00
1415,00
1372,00
-
60,50
86,70
113,00
-
1521,00
1501,00
1483,00
1465,00
1447,00
1431,00
1414,00
-
60,50
86,70
113,00
139,00
165,00
191,00
217,00
-
n = 1750 1/min
2
n = 3500 1/min
2
v = 6 mm /s
v = 40 mm /s
Q
P
1/min
kW
2
2
v = 6 mm /s
Q
1/min
P
kW
1250,00
1227,00
1205,00
1185,00
1165,00
1145,00
1126,00
-
62,40
84,10
106,00
128,00
149,00
171,00
193,00
-
v = 40 mm /s
Q
P
1/min
kW
1281,00
1271,00
1261,00
1252,00
1244,00
1235,00
1227,00
1218,00
1210,00
1202,00
1195,00
62,40
84,10
106,00
128,00
149,00
171,00
193,00
215,00
236,00
258,00
280,00
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other
viscosities than those mentioned above) and the pump speed, please refer to the individual characteristics.
12
VM 618 GB/3.96
4006
Series SM...ER..
ALLWEILER
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size
Delivery
pressure
SM...
∆p
bar
Q
1/min
P
kW
Q
1/min
P
kW
1700-42
c
20
30
40
50
60
70
80
90
100
110
120
1668,00
1613,00
1561,00
1511,00
-
70,80
101,00
131,00
161,00
-
1744,00
1720,00
1697,00
1675,00
1654,00
1633,00
1613,00
1593,00
-
70,80
101,00
131,00
161,00
191,00
221,00
251,00
281,00
-
1700-46
c
20
30
40
50
60
70
80
90
100
110
120
1953,00
1898,00
1846 00
-
80,30
115,00
150,00
-
2029,00
2005,00
1982,00
1960,00
1938,00
1918,00
1897,00
-
80,30
115,00
150,00
185,00
219,00
254,00
289,00
-
2200-42
c
20
30
40
50
60
70
80
90
100
110
120
2186,00
2120,00
2056,00
1996,00
-
92,20
131,00
170,00
210,00
-
2278,00
2249,00
2221,00
2194,00
2168,00
2143,00
2119,00
2094,00
-
92,20
131,00
170,00
210,00
249,00
288,00
327,00
366,00
-
2200-46
c
20
30
40
50
60
70
80
90
100
110
120
2548,00
2481,00
2418,00
-
104,00
149,00
195,00
-
2639,00
2610,00
2582,00
2556,00
2530,00
2505,00
2480,00
-
104,00
149,00
195,00
240,00
285,00
330,00
375,00
-
n = 1750 1/min
v = 6 mm2/s
n = 3500 1/min
v = 40 mm2/s
v = 6 mm2/s
Q
1/min
v = 40 mm2/s
P
kW
Q
1/min
P
kW
c These pump sizes are only available in fabricated steel design (please see also remarks under temperature and pressure limits page 2)
The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other
viscosities than those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 618 GB/3.96
4007
13
Series SMH...ER..
ALLWEILER
Sectional drawing
SMH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U... with mechanical seal
Part No. Denomination
1
2c
3
4
5
6
7
8c
9
12c
13c
19
20
21c
22c
23 c
24 c
25c
26c
27c
28c
29c
32c
34c
35
36
38
14
39
14
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
shaft sealing housing
pump foot
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
Part No. Denomination
40
41
42
44
46
47
48
49
51
52
53
54
55
56
57
79
80
81
83 c
107c
108
109
110
ball valve
key
straight pin
lock washer
screw plug
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spring dowel
hexagon screw
socket head cap screw
spacer ring
supporting washer
supporting ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw
Design U... with mechanical seal
at pump size 940 to 1300
c spare parts
VM 618 GB/3.96
1000
Series SMH...ER..
ALLWEILER
Sectional drawing
SMH... - horizontal foot mounted pump, external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Design D...
Part No. Denomination
1
2c
3
4
5
6
7
8c
9
10
12c
13c
16
19
20
21c
22c
23c
24 c
25c
26c
27c
28c
29c
32c
34c
35
36
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump foot
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
VM 618 GB/3.96
1001
Part No. Denomination
37
38
39
40
41
42
44
46
47
48
49
50
51
52
53
54
55
56
57
80
81
82
83c
circlip
Stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 1300)
hexagon nut
ball valve
key
straight pin
lock washer
screw plug
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spring dowel
hexagon screw
spacer ring
support ring
spring dowel
mechanical seal
c spare parts
15
Series SMF...ER..
ALLWEILER
Sectional drawing
SMF... -flange mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U... with mechanical seal
Part No. Denomination
1
2c
3
4
5
7
8c
9
12c
13c
19
20
21c
22c
23c
24c
25c
26c
27c
28c
29c
32c
34 c
35
36
38
39
40
16
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
shaft sealing housing
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
Part No. Denomination
41
42
46
47
48
49
51
52
53
54
55
79
80
81
83c
107c
108
109
110
key
straight pin
screw plug
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw
c spare parts
VM 618 GB/3.96
1002
Series SMF...ER..
ALLWEILER
Sectional drawing
SMF... -flange mounted pump, external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Design D...
Part No. Denomination
1
2c
3
4
5
7
8c
9
10
12c
13c
16
19
20
21c
22c
23c
24c
25c
26c
27c
28c
29c
32c
34c
35
36
37
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
circlip
VM 618 GB/3.96 1003
Part No. Denomination
38
39
40
41
42
46
47
48
49
50
51
52
53
54
55
80
81
82
83 c
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 1300)
hexagon nut
ball valve
key
straight pin
screw plug
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal
c spare parts
17
Series SMS...ER..
ALLWEILER
Sectional drawing
SMS... - vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Part No. Denomination
pump casing
1
pump casing insert
2c
pump cover, drive side
3
round pump foot
4
shaft sealing housing
5
pump casing cover
7
balance bush
8c
seal cover
9
gland (only with design U2)
12 c driving spindle
13c idler spindle
19
valve spring
20
balance pipe
21 c gasket
22c gasket
23c O-ring
24c gasket
25c joint washer
18
Part No. Denomination
26c joint washer
27c joint washer
28c joint washer
29c O-ring
32c gland packing ring
34c groove ball bearing
35
circlip
36
supporting washer
38
stud bolt
39
hexagon nut
40
ball valve
41
key
42
straight pin
45
lock washer
46
screw plug
47
screw plug
48
stop screw
screw plug (only with design U3)
Part No.
49
51
52
53
54
55
79
80
81
83c
107c
108
109
110
Denomination
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring
(only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw
c spare parts
VM 618 GB/3.96
1004
Series SMS...ER..
ALLWEILER
Sectional drawing
SMS... - vertical pedestal mounted pump, external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Part No.
1
2c
3
4
5
7
8c
9
10
12c
13c
16
19
20
21c
22c
23c
Denomination
pump casing
pump casing insert
pump cover, drive side
round pump foot
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design e)
valve spring
balance pipe
gasket
gasket
O-ring
VM 618 GB/3.96
1005
Part No. Denomination
24c
gasket
25c
joint washer
26c
joint washer
27c
joint washer
28c
joint washer
29c
O-ring
32c
gland packing ring
34c
groove ball bearing
35
circlip
36
supporting washer
37
circlip
38
Stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 1300)
39
hexagon nut
40
ball valve
41
key
42
straight pin
45
lock washer
Part No.
46
47
48
49
50
51
52
53
54
55
80
81
82
83c
Denomination
screw plug
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal
c spare parts
19
Series SME/SMEF... ER..
ALLWEILER
Sectional drawing
SME..., SMEF... - cartridge unit pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U... with mechanical seal
Part No. Denomination
Part No. Denomination
2c
3
5
8c
9
54
55
79
80
81
12c
13c
19
20
21c
22c
24 c
27c
28c
29c
32c
34c
35
36
38
39
40
41
42
48
49
51
20
pump casing insert
pump cover, drive side
shaft sealing housing
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
gasket
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
key
straight pin
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
83c
107c
108
109
110
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw
c spare parts
VM 618 GB/3.96 1006
Series SME/SMEF...ER..
ALLWEILER
Sectional drawing
SME..., SMEF... cartridge unit pump external ball bearing with mechanical seal, design D…and E…
external ball bearing with stuffing box, design KA2
Design D
Part No. Denomination
Part No. Denomination
2c
3
5
8c
9
10
12c
13c
16
48
49
50
51
54
55
80
81
82
83c
19
20
21c
22c
24c
27 c
28c
29c
32c
34c
35
36
37
38
39
40
41
42
pump casing insert
pump cover drive side
bearing housing
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
gasket
joint washer
joint washer
O-ring
gland packing ring
groove ball bearing
circlip
supporting washer
circlip
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 1300)
hexagon nut
ball valve
key
straight pin
VM 618 GB/3.96 1007
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal
c spare parts
21
Series SMH...ER..
ALLWEILER
Pump dimensions - not valid for fabricated design
SMH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E…
external ball bearing, with stuffing box, design KA2
z1/z2 = No of holes
pump dimensions
pump
size
40
80
120
210
280
440
660
940
1300
Sense of rotation
clockwise seen
from drive side
Valve dimensions and connections
with built-on pump type see dimension leaflet VM 618 GB/…2005, page 27
for pipeline installation see dimension leaflet VM 618 GB/…2006, page 28
Dimensions in mm
Alteration of dimensions reserved
foot dimensions
shaft end
h
k1
k2
c
n2
o
q1
q2
r
a
b
c
e
f
i
s
d
l
t
u
118
140
150
160
190
200
215
225
250
380
449
500
538
612
694
770
791
875
464
548
613
724
777
893
1025
1154
1230
175
192
202
212
247
256
307
317
387
204
248
268
288
334
354
384
404
462
315
419
460
508
552
657
720
761
795
250
289
360
388
402
457
550
531
555
130
156
185
205
220
245
270
294
316
140
140
140
140
205
205
205
205
310
180
190
190
190
300
300
300
300
350
15
18
18
18
30
30
30
30
35
190
210
210
210
280
280
280
280
400
210
225
225
225
350
350
350
350
410
215
274
325
363
370
452
528
549
520
14
18
18
18
18
18
18
18
23
19
19
24
28
32
38
42
48
48
34
45
54
60
60
72
95
105
105
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
6
6
8
8
10
10
12
14
14
c max dimension with by-pass valve, may be smaller each acc. to valve type. For return valves see dimension leaflet VM 618 GB/… 2005, page 27
pump
size
40
80
120
210
280
440
660
940
1300
22
suction flange
PN 16 DIN EN 1092-2, form B
nom. diam.
DNS
32
65
65
80
100
125
125
150
150
A
140
185
185
200
220
250
250
285
285
B
100
145
145
160
180
210
210
240
240
D
19
19
19
19
19
19
19
23
23
g1
110
125
140
155
195
200
200
220
240
delivery flange
PN 100 DIN 2547, form B
y1
18
20
20
22
24
26
26
26
26
z1
4
4
4
8
8
8
8
8
8
nom. diam
DNd
25
40
50
65
80
100
100
125
125
E
140
170
195
220
230
265
265
315
315
F
100
125
145
170
180
210
210
250
250
H
18
23
27
27
27
30
30
33
33
g2
110
125
140
155
195
200
200
220
240
drainage
y2
24
26
28
30
32
36
36
40
40
z2
4
4
4
8
8
8
8
8
8
B1/B2
G 1/4
G 1/4
G 3/8
G 1/2
G 3/4
G 3/4
G 3/4
G 3/4
G 3/4
connections
venting
pressure
gauge
E3/E4
G1/4
G1/4
G3/8
G 1/2
G3/4
G3/4
G3/4
G3/4
G3/4
VM 618 GB/02.00
M1/M2
G1/4
G1/4
G1/4
G1/4
G1/2
G1/2
G1/2
G1/2
G1/2
2000
Series SMF...ER..
ALLWEILER
Pump dimensions - not valid for fabricated design
SMF... - flange mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
z1/z2/z3 = No of holes
Valve dimensions and connections
with built-on pump type see dimension leaflet VM 618 GB/…2005, page 27
for pipeline installation see dimension leaflet VM 618 GB/…2006, page 28
pump
size
40
80
120
210
280
440
660
940
1300
pump dimensions
k2
464
548
613
724
777
893
1025
1154
1230
c
n2
175
192
202
212
247
256
307
317
387
o1
87
108
118
128
144
154
169
179
212
q1
315
419
460
508
552
657
720
761
795
q2
250
289
360
388
402
457
550
531
555
Sense of rotation
clockwise seen
from drive side
Dimensions in mm
Alteration of dimensions
reserved
flange cover
r
130
156
185
205
220
245
270
294
316
a1
190
230
260
290
310
360
380
400
410
b1
130
155
185
205
220
250
270
290
310
d
c1
130
153
163
172
175
208
227
241
259
d
c3
130
153
175
198
209
234
259
287
307
e1
160
190
220
250
260
310
320
350
360
d
f1
20
21
23
23
27
27
27
31
33
d
f2
95
92
113
120
134
136
143
145
161
shaft end
i1
130
138
168
181
195
209
239
251
267
s1
13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0
y3
20
20
22
24
27
30
30
30
32
y4
4,5
6,0
6,0
7,0
6,0
6,0
6,0
6,0
8,0
z3
4
4
4
4
4
4
4
8
8
d
19
19
24
28
32
38
42
48
48
l
34
45
54
60
60
72
95
105
105
t
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
u
6
6
8
8
10
10
12
14
14
c max dimension with by-pass valve, may be smaller each acc to valve type. For return valves see dimension leaflet VM 618 GB/… 2005, page 27
d Space to be kept free for assembling
pump
size
40
80
120
210
280
440
660
940
1300
suction flange
delivery flange
nom.
diam.
DNS
A
B
D
g1
y1
32
65
65
80
100
125
125
150
150
140
185
185
200
220
250
250
285
285
100
145
145
160
180
210
210
240
240
19
19
19
19
19
19
19
23
23
110
125
140
155
195
200
200
220
240
18
20
20
22
24
26
26
26
26
VM 618 GB/02.00
connections
venting
pressure
gauge
z1
E
F
H
g2
y2
z2
B1/B2
E3/E4
M1/M2
4
4
4
8
8
8
8
8
8
25
40
50
65
80
100
100
125
125
140
170
195
220
230
265
265
315
315
100
125
145
170
180
210
210
250
250
18
23
27
27
27
30
30
33
33
110
125
140
155
195
200
200
220
240
24
26
28
30
32
36
36
40
40
4
4
4
8
8
8
8
8
8
G1/4
G1/4
G3/8
G1/2
G3/4
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G3/8
G1/2
G3/4
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G1/4
G1/4
G 1/2
G 1/2
G 1/2
G 1/2
G 1/2
PN16DIN EN 1092-2, form B
2001
drainage
nom
diam.
DNd
PN 100 DIN 2547, form B
23
Series SMS...ER..
ALLWEILER
Pump dimensions - not valid for fabricated design
SMS... - Vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Standard motors
IEC k5
IEC
k5
size appr size appr.
71 240 180 M 650
80 275 180 L 690
90 S 305 200 L 735
90 L 330 225 S 810
100 L 365 225 M 835
112 M 380 250 M 940
132 S 445 280 S 1000
132 M 485 280 M 1050
160 M 585 315 S 1140
160 L 630 315 M 1200
pump dimensions
c
pump
size
k6
q4
c1
c3
y4
z3
s2
z4
d
l
t
u
4
4
4
250 22 220 14
280 23 240 18
320 25 280 18
4
6
6
19
19
24
34
45
54
21,5
21,5
27,0
6
6
8
210
280
440
727,0h 212 128 218,5h 338,5h 290 205 172 198 250 23 120 181 17,5 24
485,5 310 220 175 209 260 27 134 195 22,0 27
887,5 247 144 335,5
510,0 360 250 208 234 310 27 136 209 26,0 30
967,0 256 154 310,0
7,0
6,0
6,0
4
4
4
340 25 300 18
400 30 360 18
420 35 380 18
6
8
8
28
32
38
60
60
72
31,0
35,0
41,0
8
10
10
6,0
6,0
8,0
4
8
8
480 35 440 18
510 40 460 18
560 35 500 23
8
8
8
42
48
48
95 45,0
105 51,5
105 51,5
12
14
14
515,0
662,0
729,0
c max. dimension with by-pass valve, may
be smaller each according to valve type.
For return valves see dimension leaflet
VM 618 GB/...2005, page 27
d Space to be kept free for assembling
24
e1
f1
f2
i1
s1
380 270 227 259 320 27 143 239 26,0 30
400 290 241 287 350 31 145 251 22,0 30
410 310 259 307 360 33 161 267 22,0 32
a2
c2
e2
e at SMS 40 with valve DVI 38 dimension k 6 = 546,5, q 3 = 231,5 and q 4 = 296,5; screw arrangement at foot = I
f at SMS 80 with valve DVI 38 dimension k 6 = 631,5, q 3 = 212,5 and q 4 = 342,5; screw arrangement at foot = IV
g at SMS 120 with valve DVI 38 dimension k 6 = 718,5, q3 = 258,5 and q4 = 358,5; screw arrangement at foot = IV
j at SMS 210 with valve DVI 38 dimension k 6 = 795,5, q3 = 287,0 and q4 = 407,0; screw arrangement at foot = IV
The deviating dimensions as well as the screws of foot are caused by the necessary intermediary
delivery flange
PN 100 DIN 2547, form B
suction flange
PN16DIN EN 1092-2, form B
pump
size
40
80
120
210
280
440
660
940
1300
b1
shaft end
4,5
6,0
6,0
345,0
432,0
489,0
a1
foot dimensions
y3
307 169
317 179
387 212
q3
flange cover
d d
486,0e 175 87 171,0e 236,0e 190 130 130 130 160 20 95 130 13,5 20
576,0f 192 108 157,0f 287,0f 230 155 153 153 190 21 92 138 17,5 20
632,0g 202 118 172,0g 272,0g 260 185 163 175 220 23 113 168 17,5 22
1065
1193
1284
o1
d
40
80
120
660
940
1300
n2
d
nom. diam.
DNS
A
B
D
g1
y1
32
65
65
80
100
125
125
150
150
140
185
185
200
220
250
250
285
285
100
145
145
160
180
210
210
240
240
19
19
19
19
19
19
19
23
23
110
125
140
155
195
200
200
220
240
18
20
20
22
24
26
26
26
26
drainage
connections
venting pressure
gauge
leakage
oil
z1
nom. diam.
DNd
E
F
H
g2
y2
z2
B1/B3
E2/E4
M1/M2
T
4
4
4
8
8
8
8
8
8
25
40
50
65
80
100
100
125
125
140
170
195
220
230
265
265
315
315
100
125
145
170
180
210
210
250
250
18
23
27
27
27
30
30
33
33
110
125
140
155
195
200
200
220
240
24
26
28
30
32
36
36
40
40
4
4
4
8
8
8
8
8
8
G1/4
G1/4
G3/8
G1/2
G3/4
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G3/8
G1/2
G3/4
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G1/4
G1/4
G1/2
G1/2
G1/2
G1/2
G1/2
G1/4
G1/4
G3/8
G3/8
G1/2
G1/2
G1/2
G1/2
G1/2
VM 618 GB/02.00
2002
Series SME/SMEF...ER..
ALLWEILER
Pump dimensions
SME..., SMEF... - cartridge unit pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E…
external ball bearing, with stuffing box, design KA2
pump
size
40
80
120
210
280
440
660
940
1300
pump dimensions
mounting flange
i2
k
r1
r2
r3
v
y6
y7
a3
e3
s3
s4
yc
z5
150,5
169,0
195,5
213,5
229,5
257,0
294,0
310,0
318,0
445
508
579
670
732
835
959
1064
1154
82
100
112
128
138
156
180
200
216
85
105
120
140
147
171
191
214
235
86
106
121
141
148
172
192
215
236
116
163
177
197
209
258
289
292
305
18
20
23
25
28
30
35
35
40
12
16
20
21
23
25
30
30
34
128
152
182
203
217
243
266
290
310
105
130
152
175
180
205
230
250
272
12,0
12,0
14,5
14,5
18,5
18,5
18,5
24,0
24,0
M 10
M 10
M 12
M 12
M 16
M 16
M 16
M 20
M 20
14,0
16,5
19,0
21,0
22,5
25,0
28,0
31,0
34,0
6
6
6
6
6
8
8
8
8
c stated dimensions without gasket
pump
size
40
80
120
210
280
440
660
940
1300
a1
b1
d
c1
190
230
260
290
310
360
380
400
410
130
155
185
205
220
250
270
290
310
130
153
163
172
175
208
227
241
259
d
c3
130
153
175
198
209
234
259
287
307
flange cover (only with series SMEF)
d
d
e1
f1
f2
l1
s1
160
190
220
250
260
310
320
350
360
20
21
23
23
27
27
27
31
33
95
92
113
120
134
136
143
145
161
130
138
168
181
195
209
239
251
267
13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0
shaft end
y
y3
y4
z3
d
l
t
u
24,5
36,5
34,0
39,0
39,5
53,0
60,0
69,0
58,0
20
20
22
24
27
30
30
30
32
4,5
6,0
6,0
7,0
6,0
6,0
6,0
6,0
8,0
4
4
4
4
4
4
4
8
8
19
19
24
28
32
38
42
48
48
34
45
54
60
60
72
95
105
105
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
6
6
8
8
10
10
12
14
14
d Space to be kept free for assembling
VM 618 GB/3.96
2003
25
Series SM...ER..
ALLWEILER
Heating - not valid for fabricated design
Series SMH, SMF, SMS, design ...E = with heating elements for electrical heating
design ...P = with heating cartridges for steam or heat conveyors
design ...X = with heating cover for steam or heat conveyors
Design...E (with 2 heating elements, electrical)
Design...X (with heating cover)
Design...P (with 2 heating cartridges, steam/heat conveyor)
Dimensions in mm
Alteration of dimensions reserved
pump
size
40
80
120
210
280
440
660
940
1300
heating
steam/heat
conveyor
pump dimensions f
k7
k8
k9
p4
p5
q8
u1
546,5
631,5
718,5
795,5
978,5
1028
1141
1279
1380
524,5
603,5
699,5
792,5
868,0
954,0
1101
1240
1326
484
567
631
748
800
921
1050
1176
1260
274,5
314,5
339,5
404,5
466,0
497,0
551,0
709,0
771,0
234
278
271
360
398
464
500
645
705
296,5
342,5
358,5
407,0
576,5
571,0
591,0
748,0
825,0
100
120
145
170
175
200
225
244
265
H1/H2
G 1/4
G 1/4
G 1/4
G 1/4
G3/8
G3/8
G3/8
G3/8
G1/2
pipe
d1/d2
18
18
18
18
18
18
22
22
22
heating (electrical)
heating elements 230 V, 50 Hz
total
heat capacity
connec- key
(2 elements)
length
Ø
tion
width
W
240
260
300
420
460
460
680
880
1000
130
150
170
190
210
210
240
250
280
20
20
20
25
25
25
32
40
40
G3/4
G3/4
G3/4
G1
G1
G1
G11/4
G11/2
G11/2
32
32
32
41
41
41
60
60
60
heating up time of pump
in minutes at ∆t =
25°C 50°C 75°C 100°C
60
120
240
320
f Further pump dimensions see dimension leaflet VM 618 GB/ .2000 for SMH, VM 618 GB/...2001 for SMF, VM 618 GB/...2002 for SMS.
26
VM 618 GB/3.96
2004
Series SM...ER..
ALLWEILER
Valve dimensions and connections - not valid for fabricated design
Pressure relief valves built-on pumps of series SMH, SMF, SMS
Valve construction in GG (c.i.) and GGG (s.g.c.i.)
Dimensions in mm
Alteration of dimensions reserved
pump
size
SM..
max. permissible
550
210
80
550
210
120
550
210
210
280
550
0-38
0-44
0-98
0-38
0-44
0-98
0-38
0-44
0-98
0-38
0-44
0-98
0-13,5
13,5-38
900
0-98
0-13,5
13,5-38
440
900
0-98
0-13,5
13,5-38
900
0-98
660
0-18
1800
0-98
0-13,5
13,5-38
900
0-98
940
0-18
1800
0-98
0-16
1300
valve
discharge working
flowpressure
through
e
l/min
bar
210
40
2500
0-98
VM 618 GB/02.00
z 4 = No of
holes
type
c
DS 41
DS 38
DVI 38g
DS 41
DS 38
DVI 38g
DS 41
DS 38
DVI 38g
DS 41
DS 38
DVI 38g
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 47
DV 47
DVI 47
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 47
DV 47
DVI 47
DS 50
DV 50
DVI 50
DVS 50
2005
valve dimensions
bypass
design
d
k3
k4
p
v1
v2
n2
245
292
340
245
292
340
245
292
340
245
292
340
410
450
55
45
76
153
ABCD
198
261
300
198
261
300
198
261
300
198
261
300
362
402
384
384
362
402
384
384
362
402
384
384
400
-B-D
400
468
ABCD
362
402
384
384
400
410
450
f
f
360
468
-B-D
400
468
ABCD
550
620
-B-D
470
470
-
f
f
530
ABCD
ABCD
ABCD
ABCD
ABCD
ABCD
ABCD
ABCD
ABCD
-B-D
ABCD
-B-D
ABCD
-B-D
ABCD
-B-D
f
360
410
450
f
f
360
410
450
f
f
360
468
additional dimensions at.
back piping connections
pipe thread
PN 16
DIN EN 1092-2
n1
R
n3
DNr
146
G1
-
-
1
G1 /2
-
-
79
45
86
175
168
75
25
56
170
163
G1
-
-
99
25
66
192
185
G11/2
-
-
55
45
76
180
173
G1
-
-
79
45
86
202
195
G11/2
-
-
65
35
65
190
183
G1
-
-
1
89
35
76
212
205
G1 /2
-
-
135
50
98
247
-
-
270
65
135
50
50
-
f
f
55
247
-
-
270
65
162
23
71
256
-
-
279
65
162
23
23
-
f
f
28
256
-
-
279
65
272
-
-
295
65
272
-
-
295
65
307
-
-
350
80
145
40
88
145
40
40
45
f
f
45
113
145
45
113
307
-
-
350
80
185
0
48
282
-
-
305
65
f
f
5
73
282
-
-
305
65
185
0
0
5
317
-
-
360
80
185
5
73
317
-
-
360
80
220
60
130
387
-
-
390
100
60
60
f
f
150
387
-
-
390
100
145
185
220
flange dimensions
(back piping connection)
PN16 DIN EN 1092-2, form C
DNr M
P
f4
y5
z4
65 185 145 122 19
80 200 160 138 19
100 220 180 158 19
N
L
3
3
3
18
22
22
4
8
8
c DS = Pressure relief valve
with coil spring,
directly operated
DT = Pressure relief valve
with disc Springs,
directly operated
DV = Pressure relief valve
directly pilot-operated
DVI = Pressure relief valve
indirectly pilot-operated
DVS = Pressure relief valve
directly pilot-operated,
marine design for
vertical pumps
dA
B
C
D
= by-pass relief valve
= by-pass relief valve
with manual control
= return relief valve
= return relief valve
with manual control
e In the case of differential
pressure over 40 bars return
valves (type C and D )
should generally be employed
f No dimension because of
lateral adjusting screw
g With the pump types SMS 40,
80, 120 and 210 the valve
type DVI 38 only with intermediary (between pump casing
and round pump foot) possible
27
Series SM...ER..
ALLWEILER
Valve dimensions and connections - not valid for fabricated design
Pressure relief valves for pipe line Installation
valve size 44 to 56
valve size 44
valve size 23 to 38
Dimensions in mm Alteration of dimensions reserved
z4/z6 = No of holes
discharge
flow-through
from
to
l/min
5
l/min
35
20
160
50
300
100
660
200
400
600
1300
2200
3600
max
perm
working
pressure
bar
0-38
0-38
38-58
0-44
0-58
0-98
0-13,5
13,5-38
0-38
0-98
valve
type
design
c
DS23
DS29
DT29
DS38
DVI38
DVI38
DS44
DT44
DV44, DVI44
DV44, DVI44
d
EF
EF
EF
EF
E
E
EF
EF
F
F
0-18
DS47
EF
0-38
DV47, DVI47
F
0-98
DV47, DVI47
F
0-16
DS50
0-38
DV50, DVI50
0-98
0-9
0-38
0-98
DV50, DVI50
DS56
DV56
DV56
EF
F
F
EF
F
F
valve dimensions
GG, GGG, St
GG, GGG, St
GG, GGG, St
GG, GGG, St
GG, GGG, St
GGG, St
GG, GGG, GS
GG, GGG, GS
GG, GGG, GS
St
GG, GGG
St
GG, GGG
St
St
GG
St
GG
St
St
St
St
St
outlet (return)
pipe
nominal
thread diam press
l1
110
160
160
230
292
292
255
300
275
325
355
380
335
360
360
406
468
320
380
380
500
400
395
l2
115
190
190
260
280
325
e
e
380
410
e
e
e
440
500
e
e
e
520
e
e
c DS = Pressure relief valve with coil spring, directly operated
DT = Pressure relief valve with disc Springs, directly operated
DV = Pressure relief valve directly pilot operated
DVI = Pressure relief valve indirectly pilot-operated
28
connections
inlet (feeding)
material
of casing
n4
40
62
62
88
88
88
78
78
78
132
140
160
140
160
160
150
200
150
200
220
220
220
240
n5
35
50
50
57
57
57
70
70
70
112
130
160
130
160
160
140
180
140
180
180
200
200
200
DNV
V
G 3/8
G1
G1
G11/2
G11/2
G11/2
50
50
50
50
65
65
65
65
65
80
80
80
80
80
100
100
100
PN
40
40
40
100
40
40
40
40
100
40
40
40
40
100
40
40
100
nominal
diam press
Q
165
165
165
195
185
185
185
185
220
200
200
200
200
230
235
235
265
S
125
125
125
145
145
145
145
145
170
160
160
160
160
180
190
190
210
W
18
18
18
27
18
18
18
18
27
18
18
18
18
27
23
23
30
Y8 z6
22 4
22 4
22 4
28 4
24 8
22 8
24 8
22 8
30 8
26 8
24 8
26 8
24 8
32 8
24 8
24 8
36 8
R
G 3/8
G1
G1
G11/2
G11/2
G11/2
G2
G2
G2
-
DNr
50
80
80
80
80
80
100
100
100
100
100
125
125
125
PN
16
16
16
16
16
16
16
16
16
16
16
16
16
16
M
165
200
200
200
200
200
220
220
220
220
220
250
250
250
N
125
160
160
160
160
160
180
180
180
180
180
210
210
210
P
18
18
18
18
18
18
18
18
18
18
18
18
18
18
y5
18
24
20
24
20
20
24
20
24
20
20
22
22
22
z4
4
8
8
8
8
8
8
8
8
8
8
8
8
8
d E = pipe line relief valve without manual control
F = pipe line relief valve with manual control
e No dimension because of lateral adjusting screw
VM 618 GB/3.96
2006
Series SMF...ER..
ALLWEILER
Unit dimensions - not valid for fabricated design
SMF... - flange mounted pump, internal ball bearing, with mechanical seal, design U .
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D.. and E...
external ball bearing, with stuffing box, design KA2
Branch position
Suction and delivery branch
opposed out-of-line on
centerline of pump
The sense of flow may be
changed without alteration
of sense of rotation by
turning the pump casing
by 180°
Dimensions in mm
Alteration of
dimensions reserved
Sense of rotation:
clockwise seen
from drive side
Valve dimensions and connections
with built-on pump type see dimension leaflet VM 618 GB/ 2005, page 27
for pipeline installation see dimension leaflet VM 618 GB/ 2006 page 28
Additional dimensions in case of heating see dimension leaflet
VM 618 GB/ 2004 page 26
z1/ z 2 = No of holes
pump-/unit dimensions c
d
pump
size
Standard motors c
IEC
k5
IEC
k5
size appr. size
appr
71
240 180 M 650
80
275 180 L 690
90 S 305 200 L 735
90 L 330 225 S 810
100 L 365 225 M 835
112 M 380 250 M 940
132 S 445 280 S 1000
132 M 485 280 M 1050
160 M 585 315 S 1140
160 L 630 315 M 1200
foot dimensions
x1
x2
shaft end
a1
h
l1
k0
k2
n2
o1
q1
q2
r
a
b
c
f
m
s
d
l
t
u
40
80
120
190
230
260
180
180
195
130
138
168
530,5
611,0
668,0
464
548
613
175
192
202
87
108
118
315
419
460
250
289
360
130
156
185
213,0 148,0
312,0 182,0
325,0 225,0
140
140
160
170
250
250
33
40
40
207
315
315
57
60
60
11
18
18
19
19
24
34
45
54
21,5
21,5
27,0
6
6
8
210
280
440
290
310
360
210
280
280
181
195
209
777,0
842,0
955,5
724
777
893
212
247
256
128
144
154
508
552
657
388
402
457
205
220
245
351,0 231,0
397,0 247,0
489,5 289,5
180
180
190
250
355
355
40
40
40
315
410
410
60
80
80
18
23
23
28
32
38
60
60
72
31,0
35,0
41,0
8
10
10
660
940
1300
380
400
410
290
310
310
239 1090,0 1025
251 1221,0 1154
267 1280,5 1230
307
317
387
169
179
212
720
761
795
550
531
555
270
294
316
525,0 355,0
553,0 323,0
570,5 330,5
220
235
235
355
355
355
40
40
40
410
410
410
80
80
80
23
23
23
42
48
48
95
105
105
45,0
51,5
51,5
12
14
14
c Only valid for three phase A C Standard motors with enclosure
higher than IP23 In case of three-phase A C Standard motors
with enclosure IP23 and for D C motors dimensions upon request
d max dimension with by-pass valve may be smaller each
according to valve type For return valves see dimension
leaflet VM 618 GB/ 2005, page 27
pump
size
suction flange
delivery flange
PN 16 DIN EN 1092-2, form B
PN 100 DIN 2547, form B
nom. diam.
DNs
A
B
D
g1
y1
40
80
120
210
280
440
660
940
32
65
65
80
100
125
125
150
140
185
185
200
220
250
250
285
100
145
145
160
180
210
210
240
19
19
19
19
19
19
19
23
110
125
140
155
195
200
200
220
18
20
20
22
24
26
26
26
1300
150
285
240
23
240
26
VM 618 GB/02.00 3000
connections
z1
nom. diam.
DNd
E
F
H
g2
y2
4
4
4
8
8
8
8
8
25
40
50
65
80
100
100
125
140
170
195
220
230
265
265
315
100
125
145
170
180
210
210
250
18
23
27
27
27
30
30
33
110
125
140
155
195
200
200
220
24
26
28
30
32
36
36
40
8
125
315
250
33
240
40
drainage
venting
pressure
gauge
z2
B1/B2
E3/E4
M1/M2
T
4
4
4
8
8
8
8
8
G1/4
G1/4
G 3/ 8
G 1/ 2
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G 3/ 8
G 1/ 2
G3/4
G3/4
G3/4
G3/4
G1/4
G1/4
G1/4
G1/4
G1/2
G1/2
G1/2
G1/2
G1/4
G1/4
G 3/ 8
G 3/ 8
G1/2
G1/2
G1/2
G1/2
8
G3/4
G3/4
G1/2
G1/2
leakage
oil
29
Series SMH...ER..
ALLWEILER
Installation plan - not valid for fabricated design
SMH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U…
internal ball bearing, with stuffing box, design U2…
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D… and E…
external ball bearing, with stuffing box, design KA2
c Allocation of foundation screws to the base plate sizes
see dimension table of the base plates
d Leakage drain on base plate upon request only
e h3 = h or h4 (use max dimension) + h1
f h4 = size of motor, e g 180 M = 180 mm
Branch position
Suction and delivery
branch opposed
out of line on
centerline of pump
The sense of flow may
be changed without
alteration of sense of
rotation by turning the
pump casing by 180°
Valve dimensions and connections
with built on pump type see dimension leaflet VM 618 GB/ 2005 page 27
for pipeline Installation see dimension leaflet VM 618 GB/ 2006 page 28
Additional dimensions in case of heating see dimension leaflet VM 618 GB/ 2004
page 26
Dimensions in mm
Alteration of dimensions reserved
pump
size
pump
size
SMH
B1/B2 E3/E4 M1/M2
G 1/4
G 1/4
G3/8
G 1/2
G3/4
G3/4
G3/4
G3/4
G3/4
40
80
120
210
280
440
660
940
1300
Sense of rotation
clockwise seen
from drive side
connections
presventsure
ing
gauge
drainage
G 1/4
G 1/4
G3/8
G 1/2
G3/4
G3/4
G3/4
G3/4
G3/4
G 1/4
G 1/4
G 1/4
G 1/4
G1/2
G1/2
G1/2
G1/2
G1/2
z1/z2 = No of holes
delivery flange
PN 100 DIN 2547 form B
suction flange
PN 16 DIN EN 1092-2, form B
pump dimensions
h
k2
g
n2
o
p2
w
nom
diam
DNS
A
B
D
g1
y1
z1
nom
diam
DNd
E
F
H
g2
y2
z2
40
80
120
118
140
150
464
548
613
175
192
202
204
248
268
65
130
100
32
65
65
140
185
185
100
145
145
19
19
19
110
125
140
18
20
20
4
4
4
25
40
50
140
170
195
100
125
145
18
23
27
110
125
140
24
26
28
210
280
440
160
190
200
724
777
893
212
247
256
288
334
354
214
259
253
336
375
436
120
150
200
80
100
125
200
220
250
160
180
210
19
19
19
155
195
200
22
24
26
8
8
8
65
80
100
220
230
265
170
180
210
27
27
30
155
195
200
30
32
36
4
4
4
8
8
8
660
940
1300
215
225
250
1025
1154
1230
307
317
387
384
404
462
475
623
675
170
230
240
125
150
150
250
285
285
210
240
240
19
23
23
200
220
240
26
26
26
8
8
8
100
125
125
265
315
315
210
250
250
30
33
33
200
220
240
36
40
40
8
8
8
c max dimension with by pass valve may be smaller each acc. to valve type. For return valves see dimension leaflet VM 618 GB/… 2005 page 27.
30
VM 618 GB/02.00
3001/3002
Series SMH...ER..
ALLWEILER
base plate dimensions
base
plate
size
Gr
b2
b3
d1
d2
5
6
7.1
8.1
9.1
335
375
320
400
445
379
419
350
430
485
18,5
18,5
14,5
14,5
18,5
G 3/8
G 3/8
G 1/2
G 1/2
G 1/2
foundation screws
allocation
d
h1
h2
I1
50 30 725
50 30 815
70 6 900
72 6 900
87 7 1000
I2
I5
ea
dimension
500
560
630
630
710
112
127
135
135
145
4
4
4
4
4
M 16 x 160
M 16 x 160
M 12 x 160
M 12 x 160
M 16 x 250
base plate dimensions
base
plate
size
Gr
b2
b3
d1
d2
h1
h2
I1
10.1
11.1
11.4
12.1
12.3
13.1
14.1
16.3
470
520
595
575
645
575
675
675
510
560
635
615
685
615
715
715
18,5
18,5
18,5
18,5
18,5
18,5
18,5
18,5
G 1/2
G 1/2
G 1/2
G 3/4
G3 /4
G 3/4
G 3/4
G 3/4
87
90
90
115
115
115
115
115
7
7
7
8
8
8
8
8
1120
1250
1250
1400
1400
1600
1600
1800
foundation screws
allocation
d
I2
I3
I4
I5
900 450 - 110
1190 595 - 30
1190 595 - 30
1340 - 440 30
1340 - 440 30
1540 - 500 30
1540 - 500 30
1740 - 580 30
ea
dimension
6
6
6
8
8
8
8
8
M 16 x 250
M 16 x 250
M 16 x 250
M 16 x 250
M 16 x 250
M 16 x 250
M 16 x 250
M 16 x 250
d leakage drain on base plate upon request only
motor size h
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L
k5 approx.
310
335
385
415
475
515
625
670
0,75
1,1
1,5
1,1
1,5
2,2
0,75/1,1
1,5
2,2/3,0
3,0
1,5
2,2
4,0
4,0
2,2
3,0
5,5
5,5/7,5
3,0
4,0/5,5
7,5
-
4,0/5,5
7,5
11,0
11,0/15,0
7,5
11,0
15,0
18,5
750 1/min
kW 1000 1/min
at = 1500 1/min
3000 1/min
pump size
SMH
SMH
SMH
SMH
SMH
SMH
40
80
120
210
280
440
required base plate and coupling/dimension xv
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
25 V
-
5
-
28
-
25 V
-
5
-
28
-
25 V
50 V
-
5
7.1
-
28
28
-
25 V
50 V
10 V
15 V
-
5
7.1
7.1
7.1
-
28
28
28
28
-
10 V
50 V
10 V
10 V
-
6
7.1
8.1
9.1
-
38
38
38
38
-
10 V
50 V
10 V
10 V
-
6
7.1
8.1
9.1
-
38 40 V
38 25 V
38 40 V
38 50 V
- 100 V
- 240 V
motor size h
180 M
180 L
200 L
225 S
225 M
700
730
790
830
875
18,5
22,0
11,0
15,0
22,0
-
15,0
18,5/22,0
30,0
30,0/37,0
18,5
37,0
-
k5 approx.
750 1/min
kW 1000 1/min
at = 1500 1/min
3000 1/min
pump size
SMH
40
SMH
80
SMH 120
SMH 210
SMH 280
SMH 440
SMH 660
SMH 940
SMH 1300
Ku
xv
42 40 V
42 25 V
42 40 V
42 50 V
42 100 V
42 240 V
Gr
Ku
9.1
9.1
10.1
10.1
10.1
11.1
42
42
42
42
42
42
250 M
960
22,0
30,0
45,0
-
30,0
37,0
55 0
-
45,0
55,0
required base plate and coupling/dimension xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
xv
Gr
Ku
30 V
60 V
40 V
50 V
230 V
210 V
240 V
270 V
-
9.1
10.1
10.1
10.1
11.1
11.1
12.1
12.1
-
48
48
48
48
48
48
48
48
-
60 V
40 V
50 V
230 V
210 V
240 V
270 V
-
10.1
10.1
10.1
11.1
11.1
12.1
12.1
-
48
48
48
48
48
48
48
-
100 V
190 V
190 V
210 V
280 V
220 V
250 V
360 V
10.1
11.1
11.1
11.1
12.1
12.1
12.1
13.1
55
55
55
55
55
55
55
55
170 V
290 V
260 V
290 V
330 V
330 V
11.1
12.1
12.1
13.1
13.1
13.1
60
60
60
60
60
60
170 V
290 V
260 V
290 V
330 V
330 V
11.1
12.1
12.1
13.1
13.1
13.1
60
60
60
60
60
60
140 V
170 V
290 V
260 V
190 V
330 V
330 V
11.1
11.1
12.1
12.1
12.1
13.1
13.1
55
55
55
55
55
55
55
230 V
215 V
260 V
300 V
300 V
12.1
12.1
13.1
13.1
13.1
65
65
65
65
65
140 V
180 V
230 V
215 V
260 V
300 V
300 V
11.4
12.1
12.1
12.1
13.1
13.1
13.1
60
60
60
60
60
60
60
750 1/min
kW 1000 1/min
at= 1500 1/min
3000 1/min
SMH 210
SMH 280
SMH 440
SMH 660
SMH 940
SMH 1300
Gr
9.1
9.1
10.1
10.1
10.1
11.1
xv
motor size h
k5 approx.
pump size
xv
280 S
280 M
315 S
1020
1064
1130
37,0
45,0
75,0
-
45,0
55,0
90,0
-
75,0
1200
55,0
75,0
110,0
-
90,0
315 M
75,0
90,0
132,0
-
110,0
132,0
required base plate and coupling/dimension xv
xv
290 V
200 V
240 V
350 V
Gr
14.1
14.1
14.1
16.3
Ku
xv
Gr
Ku
75
75
75
75
150 V
330 V
290 V
200 V
240 V
350 V
12.3
14.1
14.1
14.1
14.1
16.3
65
65
65
65
65
65
Gr = base plate size up to 6 of cast iron,
from 7 1 onwards of fabricated steel
Ku = coupling size Polynorm A
xv
290 V
200 V
240 V
350 V
Gr
14.1
14.1
14.1
16.3
Ku
xv
Gr
75
75
75
75
150 V
290 V
290 V
200 V
240 V
350 V
12.3
14.1
14.1
14.1
14.1
16.3
Ku
xv
Gr
Ku
xv
65
75
- 230 V
65
- 230 V
65 290 V 16.3 85 290 V
65 300 V 16.3 85 300 V
65 295 V 16.3 85 295 V
Gr
14.1
14.1
16.3
16.3
16.3
Ku
xv
Gr
Ku
xv
65
- 230 V
65
65 290 V 16.3 85 290 V
65 300 V 16.3 85 300 V
65 295 V 16.3 85 295 V
Gr
Ku
14.1
16.3
16.3
16.3
75
65
65
65
i Three phase A C Standard motors construction IM B3 and enclosure higher than IP23
In case of three phase A C Standard motors with enclosure I P 2 3 as well as motor sizes
above 315 M and D C motors dimensions of base plate and coupling upon request
j upon request
31
Series SM ... ER ..
ALLWEILER
Subject to technical alterations
The mentioned performance data are to be considered as a product and per
formance abstract only. The particular operating limits can be taken from the
quotation or order acknowledgement.
ALLWEILER AG
Postfach 1140 ‚ 78301 Radolfzell
Allweilerstr. 1 ‚ 78315 Radolfzell
Germany
Tel. +49 (0)7732 86-0
Fax. + 49 (0)7732 86-436
E-mail: [email protected]
Internet: http://www.allweiler.com
VM 618 GB/08.06-Ident No 795 684