Modem Card for the Rackmount Modem System User

Transcription

Modem Card for the Rackmount Modem System User
Data/Fax Rack Mounted
Modem Card
MT5600BR-V92
Configuration Guide
Copyright and Technical Support
Data/Fax Rack Mounted Modem Card
MT5600BR-V.92
S000392F Revision F
Copyright
This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an
executive officer of Multi-Tech Systems, Inc. All rights reserved. Copyright © 2013 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content,
information, material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any
particular purpose and non-infringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof
without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Revision History
Revision
Date
Description
B
C
D
04/19/07
06/01/09
01/12/12
E
F
04/26/12
12/16/13
Updated Technical Support information
Updated switch settings for firmware release 7.02o and Technical Support information
Removed CD references. Added Multi-Tech Installation Resources site information. Removed rack
installation instructions and added reference to CC1600 documentation for rack installation.
Updated regulatory information.
Added UL translations.
Trademarks
Multi-Tech and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. All other trademarks are owned by their respective
companies.
Patents
This device is covered by one or more of the following patents: 6,031,867; 6,012,113; 6,009,082; 5,905,794; 5,864,560; 5,815,567;
5,815,503; 5,812,534; 5,809,068; 5,790,532; 5,764,628; 5,764,627; 5,754,589; 5,724,356; 5,673,268; 5,673,257; 5,644,594; 5,628,030;
5,619,508; 5,617,423; 5,600,649; 5,592,586; 5,577,041; 5,574,725; 5,559,793; 5,546,448; 5,546,395; 5,535,204; 5,500,859; 5,471,470;
5,463,616; 5,453,986; 5,452,289; 5,450,425; 5,355,365; 5,309,562; 5,301,274. Other patents pending.
Contacting Multi-Tech
Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all Multi-Tech products. Visit
http://www.multitech.com/kb.go.
Installation Resources
To download manuals, firmware, and software, visit http://www.multitech.com/setup/product.go.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com
Technical Support
Business Hours: M-F, 9am to 5pm CT
Country
Europe, Middle East, Africa:
U.S., Canada, all others:
By Email
[email protected]
[email protected]
By Phone
+(44) 118 959 7774
(800) 972-2439 or (763) 717-5863
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive
Mounds View, Minnesota 55112
Phone: 763-785-3500 or 800-328-9717
Fax: 763-785-9874
Warranty
To read the warranty statement for your product, please visit: http://www.multitech.com/warranty.go
2
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 1 – Description and Specifications .....................................................................................................5
Overview .................................................................................................................................................5
Product Documentation ...........................................................................................................................5
Telecom Safety Warnings .........................................................................................................................5
Technical Specifications ...........................................................................................................................6
Chapter 2 – Hardware Settings .......................................................................................................................7
Setting DIP Switches ................................................................................................................................7
DIP Switches 1-12 ..........................................................................................................................................7
DIP Switches 13-16 ........................................................................................................................................8
OOS (Busy Out) Toggle Switch ..................................................................................................................8
Out of Service Test Jumper .......................................................................................................................8
LED Indicators ..........................................................................................................................................9
Chapter 3 – Software Configuration .............................................................................................................. 10
Configuring Communications Software ................................................................................................... 10
PC Initialization Strings ............................................................................................................................... 10
Changing Default Parameters..................................................................................................................... 11
Macintosh Initialization Strings .................................................................................................................. 11
Configuring the Modem for Your Country or Region................................................................................ 11
Using the Global Wizard ............................................................................................................................. 11
Installing the Global Wizard ....................................................................................................................... 11
Selecting the Country through the Global Wizard ..................................................................................... 12
Using AT Commands to set Country or Region .......................................................................................... 12
Appendix A - Regulatory Compliance ............................................................................................................ 13
47 CFR Part 68 Telecom .......................................................................................................................... 13
47 CFR Part 15 Regulation ...................................................................................................................... 14
Fax Branding Statement ......................................................................................................................... 15
Canadian Limitations Notice ................................................................................................................... 15
Industry Canada ..................................................................................................................................... 15
New Zealand Telecom Warning Notice ................................................................................................... 16
South African Statement ........................................................................................................................ 17
International Modem Restrictions .......................................................................................................... 17
Other ..................................................................................................................................................... 17
Appendix B – Upgrading Firmware ............................................................................................................... 18
Data/Fax Rack Mounted Modem Card Configuration Guide
3
Contents
Checking the Modem Firmware Version ................................................................................................. 18
Checking the Current Firmware Version .................................................................................................. 18
Downloading and Installing the Flash Wizard .......................................................................................... 19
Extracting the Upgrade Files ................................................................................................................... 19
Clearing Your Stored Parameters ............................................................................................................ 19
Upgrading the Modem’s Firmware ......................................................................................................... 19
Restoring Your Parameters..................................................................................................................... 20
Appendix C – ASCII Conversion Table ............................................................................................................ 21
Index ........................................................................................................................................................... 23
4
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 1 – Description and Specifications
Overview
The MT5600BR-V92 modem card was designed for the CC1600 Series card cage. It uses ITU-T V.92 protocol to
provide quick connections, capable of downstream transmissions at speeds up to 56K bps*, and upstream
transmissions at speeds up to 48K bps when connected to V.92-compatible Internet service providers.
Product Documentation
This document is a configuration guide for the MT5600BR-V92. To download these documents, go to
http://www.multitech.com/setup/product.go and select your model from the Product drop down list.
●
CC1600 Series Card Cage User Guide (S000325) - Provides rack installation instructions.
●
MultiModem II AT Command Reference Guide (S000373)
●
Fax Service Class 1 and 1.0 Developer’s Guide (S000262)
●
Fax Service Class 2, 2.0, and 2.1 Developer’s Guide (S000239)
Telecom Safety Warnings
Before servicing, disconnect this product from its power source and telephone network. Also:
●
●
●
●
●
●
●
Never install telephone wiring during a lightning storm.
Never install a telephone jack in wet locations unless the jack is specifically designed for wet locations.
Use this product with UL and cUL listed computers only.
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at
the network interface.
Use caution when installing or modifying telephone lines.
Avoid using a telephone during an electrical storm. There may be a remote risk of electrical shock from
lightning.
Do not use a telephone in the vicinity of a gas leak.
CAUTION:
To reduce the risk of fire, use only 26 AWG or larger UL Listed or CSA Certified telecommunication
line cord.
Avertissements de sécurité télécom
Avant de l'entretien, débrancher ce produit de son réseau d'alimentation et de téléphone. également:
●
●
●
●
●
Ne jamais installer du câblage téléphonique pendant un orage électrique.
Ne jamais installer de prises téléphoniques à des endroits mouillés à moins que la prise ne soit conçue pour
de tels emplacements.
Utilisez ce produit avec UL et cUL ordinateurs répertoriés seulement.
Ne jamais toucher fils ou des bornes téléphoniques non isolés à moins que la ligne téléphonique n'ait été
déconnectée au niveau de l'interface réseau.
Faire preuve de prudence au moment d'installer ou de modifier des lignes téléphoniques.
Data/Fax Rack Mounted Modem Card Configuration Guide
5
Chapter 1 — Product Description and Specifications
●
●
Éviter d'utiliser le téléphone pendant un orage électrique. Il peut y avoir un risque de choc électrique causé
par la foudre.
N'utilisez pas un téléphone à proximité d'une fuite de gaz.
ATTENTION: Pour réduire les risques d’incendie, utiliser uniquement des conducteurs de télécommunications
26 AWG au de section supérleure.
Technical Specifications
Your MT5600BR-V92 data/fax modem meets the specifications listed below:
Category
Description
Server-to-Client Data
Rates
Client-to-Server Data
Rates
V.90 speeds when accessing a V.90 or V.92 server (actual speed depends on
server capabilities and line conditions)1
Up to 50Kbps when accessing a V.92 server (actual speed depends on server
capabilities and line conditions); otherwise, the same as client-to-client data
lines.
Client-to-Client Data
33600,31200, 28800, 26400, 24000, 21600, 19200, 16800,
Rates
14400, 12000, 9600, 7200, 4800, 2400, 1200, 0-300 bps
Fax Data Rates
14400, 12000, 9600, 7200, 4800, 2400, 1200, 0-300 bps
Data Format
Serial, binary, asynchronous, synchronous
Fax Compatibility
T.4, T30, V.21, V.27terV.29, V.34, V.17; TIA/EIA 578 Class 1, 1.0, 2TR29.2
Video Compatibility
ITU-T V.80 for H.34 video conferencing
Error Correction
ITU-T V.42 (LAP-M or MNP 4)
Data Compression
ITU-T V.44 (6:1 throughput), V.42bis (4:1 throughput), MNP 5 (2:1
throughput)
Speed Detection
Automatic speed detection and switching between available speeds
Speed Conversion
Serial port data rates adjustable to 300; 1200; 2400; 4800; 9600; 19,200;
38,400; 57,600; 115,200 bps
Mode of Operation
Full duplex data over dial-up line, 2-wire and 4-wire lease line; automatic or
manual dialing, automatic or manual answer
Flow Control
XON/XOFF (software), RTS/CTS (hardware)
Command Buffer
60 Characters
Transmission Level
-11 dBm (dial-up), -15dBm (lease line); dBm level selectable with DIP-Switch
#3 in lease line setting
Frequency Stability
±0.01%
Receiver Sensitivity
-43 dBm under worst-case conditions
AGC Dynamic Range
43 dB
Interface
EIA RS232C/ITU-TSS V.24
Diagnostics
Power-on Self Test and Local analog loop
Environmental
Temperature range 0°–50°C (32°–120°F); humidity range 20–90% (noncondensing)
Storage Temperature
-10° to +85°C (14°- 185° F)
Dimensions
10½ wide x 5½ long
Weight
8 oz
1 Although this modem is capable of 56K bps download performance, line impairments, phone infrastructure,
and other external factors may prevent maximum 56K bps connections.
Note:
6
Transmissions between the MT5600BR-V92 and other modems are limited to 33.6K bps, as are
upstream transmissions to non-V.92-compatible ISPs and downstream transmissions that are
converted more than once on the telephone network.
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 – Hardware Settings
Setting DIP Switches
The MT5600-V92 modem card contains sixteen DIP switches. How a switch operates depends on whether the
modem is in synchronous or asynchronous mode (DIP switch #12).
Factory defaults are set to use the MT5600BR-V92 to dial up a remote installation where the call is answered
automatically. Your communications software may require different settings. For the correct DIP switch settings,
check your software’s documentation.
Before you install modem cards in the card cage, verify that the DIP switch settings are correct for your
application (dial-up or lease line).
DIP Switches 1-12
*Factory default setting
Switch
Function
1
DTR Forced/DTR from Interface*
2
Flow Control &E4*
(Async/Dial-Up/Leased Line)
SDLC*/BSC (Sync)
3
4
5
6
7
8
9
Result Codes Enabled*
(Async Dial-up)
DbM Transmit -15dB/-11dB*
(Async/Sync/Leased Line)
Read switches in ASYNC*
Ignores switches in ASYNC
Read switches in SYNC*
(Sync Dial-Up/Leased Line)
Auto-Answer Enabled*
(Async/Sync/Dial-Up)
Answer/Originate*
(Async/Sync/Leased Line)
Max-Throughput Enabled*
Max - Throughput Disabled
Slave Clock Disabled*
(Sync/Dial-Up/Leased)
RTS/Normal/Forced*
(Sync/Async/Dial/Leased)
Command Mode Enabled*
(Sync/Async/Dial/Leased)
No affect
Data/Fax Rack Mounted Modem Card Configuration Guide
Position
Up*
Down
Up*
Down
Up*
Down
Up
Down*
Up
Down*
Up*
Down
Up*
Down
Up*
Down
Up*
Down
Up*
Down
Up*
Down
Up
Down*
Up
Down
Effect
DTR forced ON at all times
DTR dependent on interface
Hardware flow control
Software flow control
SDLC mode
BSC mode
Q1 Disable Responses
Q0 Enable Responses
Lease Line
Transmits at -11dB
Follows DIP-Switch 6 settings
Uses stored parameters.
Bypasses DIP-Switch 6 settings
AS/400 Mode OFF
AS/400 Mode ON
Enable Auto Answer
Disable Auto Answer
Answer Mode
Originate Mode
Compression with error correction
No compression or error correction
Slave Clocking OFF
Slave Clocking ON
RTS dependent on interface
RTS forced ON
Disable Command Mode
Enabled Command Mode
7
Chapter 2 — Hardware Settings
Switch
Function
10
Dial-Up*/Leased-Line
11
No affect in async
External Clocking (Sync)
Internal Clocking*(Sync)
Sync Mode
Async Mode*
12
Position
Effect
Up*
Down
Dial-Up Operation
Lease Line Operation
Up
Down *
Up
Down *
External Clock
Internal Clock
Synchronous Operation
Asynchronous Operation
DIP Switches 13-16
*Factory default setting
Switch
13/14
15
16
Position
Up/Up*
Down/UP
Up/Down
Down/Down
Up*
Down
Up
Down
Effect
D Read from stored parameters for speed (Default V.92)
V.34 Operation
V.32b Operation
V.22b Operation
CD/DSR from Interface
CD/DSR Forced On
2-Wire Operation
4-Wire Operation
OOS (Busy Out) Toggle Switch
The front panel has a two-position out of service (OOS) switch. Use this switch to take the modem off-hook,
which creates a busy condition for the modem.
●
Move the OOS toggle switch to BUSY to take the modem out of service. The OOS and OH LEDs light and
incoming calls get a busy signal.
If you suspect a modem is not working, use BUSY to have an optional device, such as a hunt group, roll the call to
the next available modem while you check the busy modem.
Out of Service Test Jumper
When the MT5600BR-V92 is out of service, it is busy to incoming calls. In the Test (default) setting, the modem
drives pin 25 high when the modem is in Test mode. The OOS (optional) setting forces pin 25 high and puts the
modem in a busy condition.
Note:
Jumper (shorting) plugs do not shipped with the MT5600BR-V92, but Multi-Tech Technical Support
will provide jumper plugs on request.
Test Setting (Factory Default)
8
OOS Setting (Optional)
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 — Hardware Settings
LED Indicators
The MT5600BR-V92 has ten LED diagnostic indicators.
LED
RCV
XMT
CO
56
33.6
14.4
OH
Description
Blinks while receiving data. The RCV LED state matches that of the RCV circuit on Pin 3 of the
RS232C/V.24 interface.
Blinks while transmitting data. The XMT LED state matches that of the XMT circuit on Pin 2
of the RS232C/V.24 interface.
Lights when a valid carrier tone has been detected.
Lights when the modem connects using V.92 protocol. Actual connection speed depends on
ISP server capabilities and line conditions.
Lights when the modem connects at 33,600 bps.1
Lights when the modem connects at 14,400 bps. 1
Lights when the phone line is off-hook. This occurs when the modem is dialing, on line,
answering a call, or when the OOS toggle is set to BUSY.
This LED flashes when the modem is pulse dialing in the Command Mode.
When the DTR LED is lit, the modem is permitted to answer an incoming call. When the DTR
LED is off, if the modem is dependent on DTR, it disconnects. The state of this DTR LED
matches that of the DTR circuit on Pin 20 of the RS232C/V.24 interface.
RI
Lights during the ringing interval when incoming call is received.
OOS
When the OOC LED is on, the modem is in an out of service (OOS) state. When the modem is
out of service, it is busy to incoming calls.
1 If both the 33.6 and 14.4 LEDs are lit, the modem is operating in the 16,800 to 33,600bps mode.
DTR
Data/Fax Rack Mounted Modem Card Configuration Guide
9
Chapter 3 — Software Configuration
Chapter 3 – Software Configuration
Configuring Communications Software
Configure your communications software to work with your modem, your computer, and the remote system it
calls. Most communications programs provide a default initialization string and default settings for other
parameters.
To configure you communications software to work with the MT5600BR-V92 modem:
●
Set the modem initialization string.
This is a command sequence that the software uses to configure the modem when loading communications
software or beginning a session.
●
Always begin the initialization string with AT.
●
Follow the AT with the modem reset command, &F, to ensure that you are starting with a known state.
●
Additional commands depend on the modem’s capabilities and what you want it to do.
●
Newer communications programs provide initialization strings when you select your model from a list. If
the MT5600BR-V92 is not listed, select MultiModemII.
Note:
Modem capabilities and command implementations vary from modem to modem. If you use an
initialization string intended for another modem, particularly one from another manufacturer, you
might not have access to some modem features.
PC Initialization Strings
We recommend the following initialization string for a MT5600BR-V92 connected to a PC-compatible computer:
AT &F X4 S0=0 ^M
This string:
●
Resets the MT5600BR-V92 to the factory default settings
●
Selects extended result codes with NO DIAL TONE and BUSY, and turns off auto-answer.
Notes:
If you send commands through communications software, you must end every string with ^M. This is
the ASCII code for the Return key on most keyboards, the default code for carriage return in the
MT5600BR-V92, and most communications programs.
If you send commands to the modem in terminal mode, you must press Return (<CR>) to end every
string.
In the MT5600BR-V92, the carriage return character is defined in S-register S3. If you change it, also
change the carriage return character code used in your communications software.
10
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 — Hardware Settings
Changing Default Parameters
The default values for the other parameters in modem configuration menus rarely need changing. They typically
include the dialing prefix (ATDT for touch-tone service and ATDP for rotary service), the dialing suffix (^M), the
hang-up string (+++) Response then (ATH0^M), and response messages (RING, NO CARRIER, BUSY, etc.).
Communications software with a host mode might include an auto-answer string (AT S0=1^M).
Macintosh Initialization Strings
●
To use RTS/CTS hardware flow control with a Macintosh computer, you must use serial cable wired for
hardware control.
●
Macintosh 128 and 512 models cannot use RTS/CTS flow control at all. For these models, use the following
string to turn off the default RTS/CTS hardware flow control, turn on XON/XOFF flow control, and ignore
DTR: AT &F X4 &k4 &D0 ^M
●
For hardware flow control, use the following initialization string AT &F X4 &K3 &D0 ^M
●
Add S0=0 to both strings to disable auto-answer if the MT5600BR-V92 is on a voice line.
To store the initialization string in nonvolatile memory:
1.
With your communications software open and connected to the modem’s COM port, type the initialization
string in the terminal window, substituting a carriage return for ^M.
2.
Enter AT &W0 <CR>.
When the initialization string is stored, you can use the following string to initialize your modem:
AT Z ^M
Configuring the Modem for Your Country or Region
Different countries have different requirements for how modems must function. Before using your modem,
configure it for country/region in which you are using it. You can use either the Global Wizard or AT Commands
to configure the modem for your country.
Using the Global Wizard
If using your modem with a Windows operating system, use the Global Wizard software to set the country. This
is available through the Multi-Tech Installation Resources site.
Installing the Global Wizard
1.
Go to http://www.multitech.com/setup/product.go and select your model from the Product drop down list.
2.
Click Software.
3.
Click Global Wizard link.
4.
Click Run twice. The Global Wizard installer launches.
5.
Click Next.
6.
Click Yes.
7.
Click Next.
8.
Click Finish. This completes the Global Wizard installation.
Data/Fax Rack Mounted Modem Card Configuration Guide
11
Chapter 3 — Software Configuration
Selecting the Country through the Global Wizard
1.
Click Start | All Programs |Global Wizard and select Global Wizard. The Global Wizard opens.
2.
Click Next. The Global Wizard searches for your modems and identifies them.
3.
Click Next. Select a modem to configure.
4.
Click Next.
5.
Select the country in which the modem will be used and click Next.
6.
Review your choice of country. If it is correct, click Next to configure the modem.
7.
When Global Wizard announces that the parameters have been set, click Finish to exit.
Using AT Commands to set Country or Region
Non-Windows users can configure the modem using AT commands. You must enter these commands in your
communication program’s terminal window. To configure the country/region code, the initialization string must
contain the AT command for your specific country or region.
1.
Run a communications program, such as HyperTerminal.
2.
Type AT%T19,0,nn, where nn is the country/region code in hexadecimal notation.
3.
Click Enter. The message OK displays.
4.
To verify that the correct country/region has been configured, type: ATI9 and click Enter.
The country/region code displays, for example:
Country/Region
AT Command (hexadecimal)
Result code (decimal)
Euro/NAM
AT%T19,0,34 (default)
52
A list of country/region codes can be found on the Multi-Tech Web site at
http://www.multitech.com/global/approvals.go.
12
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 — Hardware Settings
Appendix A - Regulatory Compliance
47 CFR Part 68 Telecom
1.
This equipment complies with Part 68 of the 47 CFR rules and the requirements adopted by the ACTA.
Located on this equipment is a label that contains, among other information, the registration number and
Ringer Equivalence Number (REN) for this equipment or a product identifier in the format:
For current products: US:AAAEQ##Txxxx.
For legacy products: AU7USA-xxxxx-xx-x.
If requested, this number must be provided to the telephone company.
2.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply
with the applicable 47 CFR Part 68 rules and requirements adopted by the ACTA. It’s designed to be
connected to a compatible modular jack that is also compliant.
3.
The ringer equivalence number (REN) is used to determine the number of devices that may be connected to
a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an
incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the
number of devices that may be connected to a line, as determined by the total RENs, contact the local
telephone company. For products approved after July 23, 2001, the REN for this product is part of the
product identifier that has the format US:AAAEQ##Txxxx. The digits represented by ## are the REN without
a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.
4.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required. But if advance notice isn't practical, the
telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file
a complaint with the FCC if you believe it is necessary.
5.
The telephone company may make changes in its facilities, equipment, operations or procedures that could
affect the operation of the equipment. If this happens, the telephone company will provide advance notice
in order for you to make necessary modifications to maintain uninterrupted service.
6.
If trouble is experienced with this equipment, please contact Multi-Tech Systems, Inc. at the address shown
below for details of how to have the repairs made. If the equipment is causing harm to the telephone
network, the telephone company may request that you disconnect the equipment until the problem is
resolved.
7.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public
service commission or corporation commission for information.
8.
No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees.
Unauthorized repairs void registration and warranty.
9.
If your home has specially wired alarm equipment connected to the telephone line, ensure the installation
of this equipment does not disable your alarm equipment.
If you have questions about what will disable alarm equipment, consult your telephone company or a
qualified installer.
10.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public
service commission or corporation commission for information.
Data/Fax Rack Mounted Modem Card Configuration Guide
13
Chapter 3 — Software Configuration
11.
If so required, this equipment is hearing-aid compatible.
12.
Manufacturing information:
Manufacturer:
Trade Name
Model Number:
FCC Registration No:
Ringer Equivalence No:
Modular Jack (USOC):
Service Center in USA:
Multi-Tech Systems, Inc.
MultiModem® II
MT5600BR-V92
AU7USA32234--M5-E
0.4B
RJ11C
Multi-Tech Systems, Inc.
2205 Woodale Drive
Mounds View, MN 55112
U.S.A.
47 CFR Part 15 Regulation
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
●
Reorient or relocate the receiving antenna.
●
Increase the separation between the equipment and receiver.
●
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
●
Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
14
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 — Hardware Settings
Fax Branding Statement
The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other
electronic device, including fax machines, to send any message unless such message clearly contains the
following information:
●
Date and time the message is sent
●
Identification of the business, other entity, or other individual sending the message
●
Telephone number of the sending machine or such business, other entity, or individual
This information is to appear in a margin at the top or bottom of each transmitted page or on the first page of
the transmission. This information in the margin is referred to as fax branding.
Any number of fax software packages can be used with this product. Refer to the fax software manual for setup
details. Typically, the fax branding information must be entered via the configuration menu of the software.
Canadian Limitations Notice
Notice: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This
is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that
registration was performed based on a Declaration of Conformity indicating that Industry Canada technical
specifications were met. It does not imply that Industry Canada approved the equipment.
Notice: The REN assigned to each terminal equipment provides an indication of the maximum number of
terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any
combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all
the devices does not exceed five.
Restrictions concernant le raccordement de matériel
Avis: Le présent matériel est conforme aux spécifications techniques d’Industrie Canada applicables au matériel
terminal. Cette conformité est confirmée par le numéro d'enregistrement. Le sigle IC, placé devant le numéro
d'enregistrement, signifie que l’enregistrement s’est effectué conformément à une déclaration de conformité et
indique que les spécifications techniques d'Industrie Canada ont été respectées. Il n’implique pas qu’Industrie
Canada a approuvé le matériel.
Avis: L'IES assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être
raccordés à une interface téléphonique. La terminaison d'une interface peut consister en une combinaison
quelconque de dispositifs, à la seule condition que la somme d'indices d'équivalence de la sonnerie de tous les
dispositifs n'excède pas 5.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Reglement Canadien sur le matériel
brouilleur.
Data/Fax Rack Mounted Modem Card Configuration Guide
15
Chapter 3 — Software Configuration
New Zealand Telecom Warning Notice
1.
The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that
the item complies with minimum conditions for connection to its network. It indicates no endorsement of
the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that
any item will work correctly in all respects with another item of Telepermitted equipment of a different
make or model, nor does it imply that any product is compatible with all of Telecom’s network services.
This equipment is not capable under all operating conditions of correct operating conditions of correct
operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections are likely to be
restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no
responsibility should difficulties arise in such circumstances.
2.
Immediately disconnect this equipment should it become physically damaged, and arrange for its disposal or
repair.
3.
This modem shall not be used in any manner which could constitute a nuisance to other Telecom customers.
4.
This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing. There is no
guarantee that Telecom lines will always continue to support pulse dialing.
Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise
to 'bell tinkle' or noise and may also cause a false answer condition. Should such problems occur, the user
should NOT contact the Telecom Faults Service.
The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is
readily available on almost all New Zealand telephone exchanges.
5.
Warning Notice: No '111' or other calls can be made from this device during a mains power failure.
6.
This equipment may not provide for the effective hand-over of a call to another device connected to the
same line.
7.
Some parameters required for compliance with Telecom’s Telepermit requirements are dependent on the
equipment (PC) associated with this device. The associated equipment shall be set to operate within the
following limits for compliance with Telecom’s Specifications:
For repeat calls to the same number:
●
There shall be no more than 10 call attempts to the same number within any 30 minute period for any
single manual call initiation, and
●
The equipment shall go on-hook for a period of not less than 30 seconds between the end of one
attempt and the beginning of the next attempt.
For automatic calls to different numbers:
●
8.
16
The equipment shall be set to ensure that automatic calls to different numbers are spaced such that
there is no less than 5 seconds between the end of one call attempt and the beginning of another.
For correct operation, total of the RN’s of all devices connected to a single line at any time should not
exceed 5.
Data/Fax Rack Mounted Modem Card Configuration Guide
Chapter 2 — Hardware Settings
South African Statement
This modem must be used in conjunction with an approved surge protection device.
International Modem Restrictions
Some dialing and answering defaults and restrictions may vary for international modems. Changing settings may
cause a modem to become non-compliant with national regulatory requirements in specific countries. Also note
that some software packages may have features or lack restrictions that may cause the modem to become noncompliant.
Other
The above country-specific examples do not cover all countries with specific regulations; they are included to
show you how each country may differ. If you have trouble determining your own country's requirements, check
with Multi-Tech's Technical Support for assistance.
Data/Fax Rack Mounted Modem Card Configuration Guide
17
Appendix B – Upgrading Firmware
Your modem is controlled by semi-permanent firmware, which is stored in flash memory. Multi-Tech's firmware
remains stored in memory when the modem is turned off and can be upgraded as new features are added.
Checking the Modem Firmware Version
Check the current firmware version to determine if an update is needed:
1.
Run a terminal program, such as HyperTerminal.
2.
In the terminal window, type AT&F. Even if you cannot see the AT&F command on your screen, be sure to
type it completely, and then press Enter. If the modem does not respond with OK, repeat the AT&F
command.
3.
Now type ATI3, press Enter and record your results. The firmware version should appear first in the
response, for example:
4.
ACF3_V1.702a_V90_P21_FSH
5.
The number after the V is the current version number.
Checking the Current Firmware Version
Identify the current version of the firmware at the Multi-Tech site. If your modem already has the current
firmware, there is no need to update it.
1.
Go to http://www.multitech.com/setup/product.go and select your model from the Product drop down list.
2.
Click Firmware. The firmware zip file name contains the version number. For example, hhgg702o.zip,
indicates version 702o.
3.
Compare the version number on the modem to the version on the site. If the versions match, there is no
need to update.
Make sure you compare any letters following the version number. If there was a minor release, the letter
may change instead of the number.
Warning: The first digit of the new firmware must match the first digit of the old firmware, or the modem may
not work properly; e.g., if your current firmware version is 4.16, replace it only with 4.xx firmware, not
6.xx firmware.
18
Data/Fax Rack Mounted Modem Card Configuration Guide
Appendix B — Upgrading Firmware
Downloading and Installing the Flash Wizard
1.
If you are not on the MT5600BR-V92 page, go to http://www.multitech.com/setup/product.go and select
the model from the Product drop down list.
2.
Click Software.
3.
Click the Flash Wizard utility link and click Open.
4.
Click Next to start through the Flash Wizard installation. Note the folder where the Flash Wizard will be
installed; you’ll need to extract the upgrade file to the same location.
5.
Click Next and then click Finish.
Extracting the Upgrade Files
1.
Click Firmware and then click the firmware upgrade link.
2.
Click Open and then click Extract.
3.
Select the folder where you installed the Flash Wizard and click Extract. The default folder is C:\Program
Files\Multi-Tech Systems\Flash Wizard.
Clearing Your Stored Parameters
Before you flash your modem, record the parameters that are currently stored in it, so you can reprogram it
after flashing. After you have recorded them, send the AT&F command to reset the modem to clear the stored parameters.
1.
Run your favorite terminal program, such as HyperTerminal.
2.
In the program’s terminal window, type AT&V and press Enter to list your modem’s current parameters.
3.
Record your parameters by saving the screens and sending them to your printer.
4.
Type AT&F and press Enter to clear your stored parameters and reset your modem to factory default.
5.
Close the terminal program.
Upgrading the Modem’s Firmware
Warning:
1.
Never install an older version of firmware over a newer version. This destroys the flash PROM! If
the flash PROM is destroyed, the modem must be sent in for repair.
Click Start | Programs | Flash Wizard to launch the Flash Wizard. The Identifying Devices dialog box is
displayed as Flash Wizard locates and identifies the devices connected to your system.
Note:
If the message ERROR: No valid devices detected is displayed, verify that the modem is turned on
and that all cables are correctly and securely attached.
2.
Select the modem to be upgraded, and then click Next.
3.
Select the port to be upgraded and the appropriate .HEX file, and then click Next.
Note:
Do not use FLASHLDR.HEX. This file is used internally by Flash Wizard.
Data/Fax Rack Mounted Modem Card Configuration Guide
19
Appendix B — Upgrading Firmware
Caution: If the upgrade is disrupted at this state, your modem may become inoperable. Wait for Next to
become active before proceeding.
Programming Complete appears and Next becomes active when the flash upgrade is complete.
4.
Click Next to continue.
5.
Click Finish to exit the Flash Wizard.
Restoring Your Parameters
Your modem has been updated. Open your terminal program to reprogram your modem parameters or to
confirm the update by typing ATI3 in the terminal window and pressing Enter.
20
Data/Fax Rack Mounted Modem Card Configuration Guide
Appendix C – ASCII Conversion Table
CTRL
CODE
HEX
DEC
CODE
HEX
DEC
CODE
HEX
DEC
CODE
HEX
DEC
@
NUL
00
0
SP
20
32
@
40
64
`
60
96
A
SOH
01
1
!
21
33
A
41
65
a
61
97
B
STX
02
2
"
22
34
B
42
66
b
62
98
C
ETX
03
3
#
23
35
C
43
67
c
63
99
D
EOT
04
4
$
24
36
D
44
68
d
64
100
E
ENQ
05
5
%
25
37
E
45
69
e
65
101
F
ACK
06
6
&
26
38
F
46
70
f
66
102
G
BEL
07
7
’
27
39
G
47
71
g
67
103
H
BS
08
8
(
28
40
H
48
72
h
68
104
I
HT
09
9
)
29
41
I
49
73
i
69
105
J
LF
0A
10
*
2A
42
J
4A
74
j
6A
106
K
VT
0B
11
+
2B
43
K
4B
75
k
6B
107
L
FF
0C
12
,
2C
44
L
4C
76
l
6C
108
M
CR
0D
13
-
2D
45
M
4D
77
m
6D
109
N
SO
0E
14
.
2E
46
N
4E
78
n
6E
110
O
SI
0F
15
/
2F
47
O
4F
79
o
6F
111
P
DLE
10
16
0
30
48
P
50
80
p
70
112
Q
DC1
11
17
1
31
49
Q
51
81
q
71
113
R
DC2
12
18
2
32
50
R
52
82
r
72
114
S
DC3
13
19
3
33
51
S
53
83
s
73
115
T
DC4
14
20
4
34
52
T
54
84
t
74
116
U
NAK
15
21
5
35
53
U
55
85
u
75
117
V
SYN
16
22
6
36
54
V
56
86
v
76
118
W
ETB
17
23
7
37
55
W
57
87
w
77
119
X
CAN
18
24
8
38
56
X
58
88
x
78
120
Y
EM
19
25
9
39
57
Y
59
89
y
79
121
Z
SUB
1A
26
:
3A
58
Z
5A
90
z
7A
122
[
ESC
1B
27
;
3B
59
[
5B
91
{
7B
123
\
FS
1C
28
<
3C
60
\
5C
92
|
7C
124
]
GS
1D
29
=
3D
61
]
5D
93
}
7D
125
^
RS
1E
30
>
3E
62
^
5E
94
~
7E
126
_
US
1F
31
?
3F
63
_
5F
95
DEL
7F
127
21
Data/Fax Rack Mounted Modem Card Configuration Guide
Appendix C— ASCII Conversion Table
NUkL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
22
Null, or all zeros
Start of Header
Start of Text
End of Text
End of
Transmission
Enquiry
Acknowledge
Bell or Alarm
Backspace
Horizontal Tab
Line Feed
VT
FF
CR
SO
SI
Vertical Tab
Form Feed
Carriage Return
Shift Out
Shift In
SYN
ETB
CAN
EM
SUB
Sync
End Transmission Block
Cancel
End of Medium
Substitute
DLE
DC1
DC2
DC3
DC4
NAK
Data Link Escape
Device Control 1
Device Control 2
Device Control 3
Device Control 4
Negative Acknowledge
ESC
S
GS
RS
US
DEL
Escape
File Separator
Group Separator
Record Separator
Unit Separator
Delete
Data/Fax Rack Mounted Modem Card Configuration Guide
Appendix C — ASCII Conversion Table
Index
A
ASCII conversion table ............................................ 21
asynchronous ........................................................... 7
auto-answer...................................................... 10, 11
B
berg jumper .............................................................. 8
busy .......................................................................... 8
C
carriage return ........................................................ 10
configuration .......................................................... 10
configure modem
AT commands ...................................................... 12
Global Wizard ...................................................... 11
country ................................................................... 11
D
G
Global Wizard ........................................................ 11
I
Industry Canada ..................................................... 15
initialization string ................................................. 10
international modem restrictions.......................... 17
N
New Zealand Telecom warning notice .................. 16
O
operating system compatibility ................................6
out of service toggle .................................................8
P
parameters ............................................................ 11
data rates.................................................................. 6
DIP switches.............................................................. 7
DTR signal ............................................................... 11
result codes............................................................ 10
E
S
EMC requirements
United States ....................................................... 14
servicing your modem ........................................... 14
South African Statement ....................................... 17
S-registers
S3 ........................................................................ 10
synchronous..............................................................7
F
factory default settings............................................. 7
fax branding statement .......................................... 15
FCC .......................................................................... 14
Flash Wizard ........................................................... 19
flow control ........................................................ 6, 11
Data/Fax Rack Mounted Modem Card Configuration Guide
R
X
XON/XOFF .............................................................. 11
23