NEVOswitch 5x
Transcription
NEVOswitch 5x
NEVOswitch 5x ES EN Hoja Técnica Data Sheet w w w. t e l e v e s . c o m NEVOswitch 5x 2 MSW 5x MSW 5x QUAD EN New range of input/multiple output switches, (from 4 to 32, according to reference). It can be used as a cascade element since it has 5 outputs to connect to other switches and increase the number of users. It has the following powering options: - Through the Power DC Jack (12 Vdc) - Through the V-Low input (12 Vdc). - Through the TERR input or output. - Applying 12 /18V at any user output. 12V DC passes through the Terr and V-LOW input/output to power pre-amplifiers, BOSS antennas, LNB or other elements (cascade). The switch can generate the required voltage or voltage + tone (QUAD references) so it’s compatible with any QUAD LNB. ES SAT para hacerlo compatible con LNB QUAD. Nueva gama de conmutadores de 5 entradas y múltiples salidas de usuario, (4…32 según ref. ). Dispone de otras 5 salidas de paso que permiten encadenar varios elementos ampliando el número de usuarios finales de la instalación (cascada). En el caso de la entrada/salida Ter se puede seleccionar el sentido de paso de la corriente mediante el switch 1. Dispone de las siguientes opciones de alimentación: - A través del jack de Power DC (12V) - A través de la línea V-Low (12VDC) - A través de la entrada o salida de la señal TERR. - Aplicando entre 12 y 18V en los conectores de salida de usuario. El paso de alimentación 12 Vdc es hacia las entradas/salidas Ter, V-Low, para la alimentación de preamplificadores, antenas BOSS, LNB ú otros elementos encadenados (cascada). En las referencias QUAD, el multiswitch genera las diferentes combinaciones de tensión y tono hacia la entradas Esta gama incorporá el sistema ECO por el cual el consumo de la instalación se reduce a medida que disminuye el número de usuarios conectados. Incluso el consumo es 0 A, si no se utiliza alimentación local y no hay ningún usuario conectado. En este caso para poder ver la señal Terrestre sería necesario que al menos un usuario estuviera alimentando la instalación. Para un funcionamiento correcto de la instalación es necesario cargar el paso de las señales con 75 ohmios, para ello se debe configurar el switch 2 en la posición en el último modulo de la cascada. Permite regular el nivel de salida de cada usuario de manera individual (opción no disponible en la gama QUAD). The user can select the direction of the current/voltage through the TERR input/output using the Switch No. 1. This range of products has been designed with the ECO system: as the number of users decreases, the power consumption of the system will decrease as well. When no users are connected and there’s no local mains, the consumption will go down to 0A. In this case scenario, to see the DTT signal at least one user must be connected to the system to power it. Any signal must balanced to 75 ohms (Switch No. 2) in the last element of the chain for the proper operation of the system. This range allow to control the output signal level of every user individually. (Not available for the QUAD range). 3 MSW 5x Splitter MSW 5x Tap MSW 5x Amplifier ES Estos dispositivos complementan la gama anterior de MSW de forma que se consigue ampliar la instalación a un mayor número de usuarios optimizando la señal que le llegaría a cada uno. Nota / Note: Switch 1 En los amplificadores mediante el switch , podemos activar/desactivar el paso de corriente para la alimentación de preamplificadores, antenas BOSS,… T EN This range of products has been designed as a complement to the former MSW range, so any facility can be easily extended to more users, optimizing every output signal. The voltage/current can be activated/deactivated in the MSW amplifiers to power pre-amplifiers, BOSS antennas, etc.. Switch 2 NEVOswitch 5x 4 Especif. técnicas Technical specifications Tipo Type Margen frec. Frequency range Nivel de salida Max output level Ganancia máxima Max gain Ecualizador Equaliser Pérdidas de paso Through losses Pérdidas deriv. Tap losses (adjustable -12dB) Aislamiento IN-OUT Isolation IN-OUT Paso corriente LNB control signals Alimentación Powering Paso DC DC pass SAT MHz TER SAT dBμV TER 714503 714504 714505 MS56C MS58C MS512C MS516C 5x5x4 5x5x6 5x5x8 950-2400 47-862 109 105 5x5x12 5x5x16 EN50083-3 IM35dBc DIN 45004-B - TER SAT TER dB SAT -4±2 TER -3±1 -5±2 -5±5* - 10 ± 5 * SAT Max Min -5±5* -8±5* TER Max -3±5* -5±5 mA A Vdc LNB/TER -8±2 -3±5* SAT >30 / Input max. Total 250 1 12 In-Out / Out-In ** Max. consumption mA Rango de temperatura Temperatura Range ºC Indice de protección Protection level IP Peso Dimensiones Weight Dimensions * 714502 MS54C SAT Consumo máx. ( ) Ajustable -12dB / Adjustable -12dB 714501 Power Supply 12Vdc (PWR) Receiver (12/18V) g mm ( 65 ± 5 **) Bidireccional / Bidirectional 105 ± 10 130 ± 10 765 800 33 *** –5….+45 ºC IP20 365 400 140x120x30 ( ***) 33 x nº users + PWR if PSU is not used 140x255x30 5 714506 714507 714402 714403 714404 714405 714901 714902 714903 714904 714905 714509 MS524C MS532C MS56NCQ MS58NCQ MS512NCQ MS516NCQ AZ512G AZ515G AZ520G AZ525G SAV525G MS530VGQ 5x5x24 5x5x32 5x5x6 QUAD 5x5x5 5x5x5 5x5x5 5x5x5 5x5x5 5x5 5x5x8 QUAD 5x5x12 QUAD 5x5x16 QUAD 950-2400 47-862 109 105 - 10 ± 5 - 12 ± 5 -4±2 - 115 - - 25 ± 4 - 27 ± 2 - 7 -5±5 -8±4 6 -1,5 ±0,5 -4±1 11 -1,5 ±0,5 -4±1 17 - -7±3 - 10 ± 3 -3±1 -5±2 -5±5* -9±5* -5±5* - 12 ± 3 * -5±5 -8±5 -5±5 - 10 ± 5 - 15 ± 3 - 17 ± 3 - 21 ± 3 - 26 ± 3 - -5±5* -8±5* -3±5 -3±5 - 12 ± 1 - 15 ± 1 - 20 ± 1 - 25 ± 1 - >30 >25 250 1 12 In-Out / Out-In ** 200 ± 15 235 ± 25 500 250 - 250 1 12 In-Out / Out-In - - - 400 140x120x 30 330 140x120x30 In-Out / Out-In 65 ± 5 105 ± 10 In-Out / Out-In** 130 ± 10 33 *** >25 - –5….+45 ºC IP20 1200 1600 140x383x30 140x510x30 400 140x120x30 765 800 140x255x30 NEVOswitch 5x 6 Modo de instalación / Installation mode Ejemplo de aplicación 1 / Example of implementation 1 1 747202 SPU44EN 2 MADE IN SPAIN T TERR. H-LOW V-LOW 12V V-HIGH H-HIGH 1 5 2 3 6 SAT STB SATELLITE MULTISWITCH MULTISCHALTER 3 714503 Art.Nr MS58C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 4 TERR. 12V V-LOW 12V 7 5x5x8 H-LOW 8 x 47 - 2400 MHz 8 V-HIGH H-HIGH POWER 12V 732210 714501- MS54C 714502 - MS56C 714503 - MS58C 714504 - MS512C 714505 - MS516C 714506 - MS524C 714507 - MS532C 7 Ejemplo de aplicación 2 / Example of implementation 2 Ejemplo de aplicación 3 /Example of implementation 3 747202 SPU44EN 747202 SPU44EN MADE IN SPAIN MADE IN SPAIN T TERR. H-LOW V-LOW 12V V-HIGH T H-HIGH TERR. V-LOW 12V H-LOW 17V V-HIGH 12V 22KHz H-HIGH 17V 22KHz 1 1 5 2 6 5 2 SAT STB SATELLITE MULTISWITCH MULTISCHALTER 3 714503 5x5x8 SAT STB 714403 Art.Nr MS58C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 4 6 SATELLITE MULTISWITCH QUAD QUAD MULTISCHALTER 3 7 V-LOW 12V H-LOW Art.Nr MS58NCQ 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 8 x 47 - 2400 MHz 4 8 x 47 - 2400 MHz 8 8 TERR. 12V TERR. 12V 7 5x5x8 V-HIGH V-LOW 12V H-LOW V-HIGH H-HIGH POWER 12V H-HIGH POWER 12V 732210 714501- MS54C 714502 - MS56C 714503 - MS58C 714504 - MS512C 714505 - MS516C 714402 - MS56NCQ 714403 - MS58NCQ 714404 - MS12NCQ 714405 - MS16NCQ NEVOswitch 5x 8 Ejemplo de aplicación 4 / Example of implementation 4 747202 SPU44EN 714509 MSV530VGQ MADE IN SPAIN TERR. H-LOW V-LOW V-HIGH H-HIGH V-LOW TAP-20 TERR. TAP-20 714903 - AZ520G MADE IN SPAIN TERR. H-LOW V-LOW V-HIGH 732210 H-HIGH GAIN ADJUST SLOPE ADJUST 5x5 AMPLIFIER VERSTÄRKER 714509 H-LOW TAP-20 4 x 950 - 2400 MHz 1 x 5 - 862 MHz Art.Nr MS530VGQ TERR. H-LOW V-LOW H-HIGH V-HIGH POWER 12V VDE V-HIGH TAP-20 TAP SYSTEMABZWEIGER 714903 5x Art.Nr AZ520G 4x 950 - 2400MHz H-HIGH TAP-20 1x 47 - 862MHz Tap loss 20dB I MAX 0,3A/ 714501 MS54C V-LOW TERR. H-LOW V-HIGH H-HIGH MADE IN SPAIN TERR. H-LOW V-LOW 12V V-HIGH H-HIGH 1 714901 - AZ512G 2 SATELLITE MULTISWITCH MULTISCHALTER 3 714501 4 5x5x4 MADE IN SPAIN Art.Nr MS54C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz TERR. H-LOW V-LOW V-HIGH H-HIGH TERR. 4 x 47 - 2400 MHz V-LOW H-LOW V-LOW V-HIGH H-HIGH TERR. V-LOW TAP-12 TERR. 12V V-LOW 12V H-LOW V-HIGH TERR. TAP-12 H-HIGH H-LOW POWER 12V H-LOW TAP-12 SPLITTER MULTISWICH MULTISCHALTER V-HIGH Ref.714905 5x5x5 V-HIGH TAP-12 Art.Nr SAV525G TAP SYSTEMABZWEIGER 714901 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 5x Art.Nr AZ512G H-HIGH I TERR. V-LOW H-LOW MAX 0,3A/ V-HIGH 4x 950 - 2400MHz H-HIGH TAP-12 714905 - SAV525G H-HIGH 1x 47 - 862MHz Tap loss 12dB I MAX 0,3A/ TERR. V-LOW H-LOW V-HIGH H-HIGH MADE IN SPAIN TERR. MADE IN SPAIN TERR. H-LOW V-LOW V-HIGH H-HIGH V-LOW TAP-20 TERR. TAP-20 714903 - AZ520G MADE IN SPAIN TERR. H-LOW V-LOW V-HIGH H-HIGH H-LOW TAP-20 V-LOW TAP-20 V-HIGH TAP-20 TAP SYSTEMABZWEIGER 714903 V-LOW TERR. H-HIGH 5 6 3 7 4 8 9 13 10 14 TERR. TAP-20 H-LOW TAP-20 1x 47 - 862MHz V-HIGH TAP-20 Tap loss 20dB I MAX 0,3A/ 714503 MS58C 714903 - AZ520G V-HIGH Art.Nr AZ520G 4x 950 - 2400MHz H-HIGH TAP-20 5x H-LOW V-LOW 12V 1 2 H-LOW V-HIGH TAP SYSTEMABZWEIGER 714903 H-HIGH 4x 950 - 2400MHz H-HIGH TAP-20 5x Art.Nr AZ520G 1x 47 - 862MHz Tap loss 20dB I MAX 0,3A/ MADE IN SPAIN TERR. TERR. H-LOW V-LOW 12V V-HIGH V-LOW H-LOW V-HIGH H-HIGH H-HIGH 1 5 2 6 MADE IN SPAIN TERR. H-LOW V-LOW 12V V-HIGH H-HIGH 11 15 1 SATELLITE MULTISWITCH MULTISCHALTER 3 714503 8 x 47 - 2400 MHz 8 SATELLITE MULTISWITCH MULTISCHALTER 3 TERR. 12V V-LOW 12V H-LOW V-HIGH 16 2 Art.Nr MS58C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 4 12 7 5x5x8 714501 H-HIGH POWER 12V Art.Nr MS54C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 4 TERR. 12V V-LOW 12V 5x5x4 H-LOW 4 x 47 - 2400 MHz V-HIGH H-HIGH POWER 12V MADE IN SPAIN 714501 MS54C TERR. 714507 MADE IN SPAIN H-LOW V-LOW V-HIGH H-HIGH 714901 - AZ512G TERR. TAP-12 MADE IN SPAIN TERR. 17 21 18 22 19 23 20 24 H-LOW V-LOW V-HIGH H-HIGH 714902 - AZ515G H-LOW TAP-12 V-LOW TAP-15 V-HIGH TAP-12 TAP SYSTEMABZWEIGER 714901 5x 714505 MS516C V-LOW TERR. 25 1x 47 - 862MHz 29 26 V-HIGH TAP-15 Tap loss 12dB I MAX 0,3A/ TERR. TAP-15 H-LOW TAP-15 Art.Nr AZ512G 4x 950 - 2400MHz H-HIGH TAP-12 H-LOW V-HIGH TAP SYSTEMABZWEIGER 714902 H-HIGH 30 5x Art.Nr AZ515G 4x 950 - 2400MHz H-HIGH TAP-15 27 1x 47 - 862MHz 31 Tap loss 15dB I MAX 0,3A/ MADE IN SPAIN TERR. H-LOW V-LOW 12V V-HIGH TERR. H-HIGH 1 V-LOW H-LOW V-HIGH H-HIGH 28 32 TERR. 12V V-LOW 12V H-LOW V-HIGH H-HIGH POWER 12V 5 MADE IN SPAIN TERR. 2 6 3 V-LOW 12V H-LOW V-HIGH H-HIGH 1 5 2 6 3 7 7 4 8 4 SATELLITE MULTISWITCH MULTISCHALTER 714505 8 714507 MS532C 5x5x16 Art.Nr MS516C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 16 x 47 - 2400 MHz MADE IN SPAIN 9 13 10 14 11 15 TERR. V-LOW H-LOW V-HIGH H-HIGH GAIN ADJUST SLOPE ADJUST 714509 MSV530VGQ SATELLITE MULTISWITCH MULTISCHALTER 714504 5x5x12 Art.Nr MS512C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 12 x 47 - 2400 MHz 9 10 12 16 11 TERR. 12V V-LOW 12V H-LOW V-HIGH 5x5 AMPLIFIER VERSTÄRKER H-HIGH POWER 12V 714509 4 x 950 - 2400 MHz 1 x 5 - 862 MHz Art.Nr MS530VGQ 12 TERR. VDE V-LOW H-LOW V-HIGH H-HIGH POWER 12V TERR. 12V V-LOW 12V H-LOW V-HIGH H-HIGH POWER 12V 732210 714504 MS512C V-HIGH H-HIGH 714509 MSV530VGQ 32 x 47 - 2400 MHz 5x5 AMPLIFIER VERSTÄRKER TERR. VDE TERR. H-LOW SLOPE ADJUST 5x5x32 Art.Nr MS532C 4 x 950 - 2400 MHz 1 x 47 - 862 MHz 714509 V-LOW TAP-12 V-LOW GAIN ADJUST SATELLITE MULTISWITCH MULTISCHALTER 4 x 950 - 2400 MHz 1 x 5 - 862 MHz Art.Nr MS530VGQ V-LOW H-LOW V-HIGH H-HIGH POWER 12V 732210 9 Ref Art. Nr. RANGO DE PRODUCTOS PRODUCT RANGE Descripción Description 714501 MS54C Multiswitch 5x4 5x4 Multiswitch 714502 MS56C Multiswitch 5x6 5x6 Multiswitch 714503 MS58C Multiswitch 5x8 5x8 Multiswitch 714504 MS512C Multiswitch 5x12 5x12 Multiswitch 714505 MS516C Multiswitch 5x16 5x16 Multiswitch 714506 MS524C Multiswitch 5x24 5x24 Multiswitch 714507 MS532C Multiswitch 5x32 5x32 Multiswitch 714402 MS56NCQ Multiswitch 5x6 QUAD 5x6 Multiswitch QUAD 714403 MS58NCQ Multiswitch 5x8 QUAD 5x8 Multiswitch QUAD 714404 MS512NCQ Multiswitch 5x12 QUAD 5x12 Multiswitch QUAD 714405 MS516NCQ Multiswitch 5x16 QUAD 5x16 Multiswitch QUAD 714509 MS530VGQ Amplificador 5x5 5x5 Amplifier 714901 AZ512G Derivador 5x5x5 (12dB) 5x5x5 Tap (12dB) 714902 AZ515G Derivador 5x5x5 (15dB) 5x5x5 Tap (15dB) 714903 AZ520G Derivador 5x5x5 (20dB) 5x5x5 Tap (20dB) 714904 AZ525G Derivador 5x5x5 (25dB) 5x5x5 Tap (25dB) 714905 SAV525G Repartidor 5 x 5 x 5 5x5x5 Splitter NEVOswitch 5x ES 10 Descripción de Simbología de seguridad eléctrica How to use the equipment safely: Instrucciones de seguridad • Para evitar el riesgo de choque eléctrico no abrir el equipo. Condiciones generales de instalación: • Antes de manipular o conectar el equipo leer este manual. • Para reducir el riesgo de fuego o choque eléctrico, no exponer el equipo a la lluvia o a la humedad. • Deje un espacio libre alrededor del aparato para proporcionar una ventilación adecuada. • El aparato no debe ser expuesto a caídas o salpicaduras de agua. No situar objetos o recipientes llenos de agua sobre o cerca del aparato si no se tiene la sufi ciente protección. • No situar el equipo cerca de fuentes de calor o en ambientes de humedad elevada. • No situar el equipo donde pueda estar sometido a fuertes vibraciones o sacudidas. Operación segura del equipo: • La tensión de alimentación de éste producto se suministra a través de las fuentes de alimentación ref.7321 y 7328 (230V~ / 12V). • Si algún líquido u objeto se cayera dentro del equipo, por favor recurra al servicio técnico especializado. • Para desconectar el equipo de la red, tire del conector, nunca del cable de red. • No conectar el equipo hasta que todas las demás conexiones del equipo hayan sido efectuadas. • Do not place the equipment where it may be affected by strong vibrations or knocks. • Este símbolo indica que el equipo cumple los requerimientos de seguridad para equipos de clase II. • Este símbolo indica que el equipo cumple los requerimientos del marcado CE. EN Important safety instructions General installation conditions: • Before handling or connecting the equipment, please read this manual. • In order to reduce the risk of fi re or electric shock, do not expose the equipment to rain or moisture. • Please allow air circulation around the equipment. • The equipment must not come into contact with water or even be splashed by liquids. Do not place containers with water on or near the equipment if it is not adequately protected. • Do not place the equipment near sources of heat or in excessively moisture conditions. • The powering voltage for this product is provided by the PSUs ref.7321 and 7328 (230V ~ / 12V). • If any liquid or object falls inside the equipment, please contact a specialized technician. • To disconnect the equipment from the mains, pull from the connector, and never pull from the cable. • Do not connect the equipment to the mains until all the other connections have been made. Description of the electrical safety symbols • To avoid the risk of fire or electric shock, do not open the equipment. • This symbol indicates that the equipment complies with the safety requirements for class II equipment. • This symbol indicates that the equipment complies with the safety requirements for equipment of marked CE. DECLARACIÓN DE CONFORMIDAD DECLARATION OF CONFORMITY DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ www.televes.com 11 televes.com