Broadband Catalog 2012

Transcription

Broadband Catalog 2012
> Broadband
Power
Total Power Solutions by ALPHA Technologies
The Alpha Group - Total Power Solutions
>Alpha Power
Alpha pioneered the concept of reliable uninterruptible power for communications networks, and in the process has set a
35-year precedent for visionary, market-driven power solutions. Today, with millions of power systems installed worldwide, we
continue to focus on providing the most reliable, innovative and energy efficient powering solutions.
>Global Reach
With millions of powering systems installed, and sales, manufacturing and service facilities located worldwide, we are able to
help you in a language you’ll understand. This global reach gives us the expertise to provide your specific power solution.
>Our Goal: Reducing Your Total Cost of Ownership
>Reliability
We are engineering the next generation of
power technologies committed to reliability,
cost savings and best-in-class performance.
>Sustainability
Running a more efficient powering network
can reduce the resources consumed and
your operational expenses.
>Intelligence
Instead of giving you data, intelligent products
give you answers. We are working to provide
the answers to optimize system performance.
>Efficiency
Through proper load matching and power
supply sizing, tailored powering systems
can perform at up to 94 percent efficiency.
Table of Contents
>Total Power Solutions
5-11
>Generators51-55
System Solutions....................................................6
AlphaGen™ Curbside............................................52
Installation and Construction Services...................7
Portable AC and DC Generators..........................53
Preventative Maintenance......................................8
AlphaGen™ Portable Trailer..................................54
Repairs and Refurbishments................................ 10
Customer Service................................................. 11
>AlphaCell® Batteries
57-63
AlphaCell 3.5HP and 4.0HP.................................58
>CableUPS Power Supplies
13-23
AlphaCell HP Runtime..........................................59
XM3-HP................................................................ 14
AlphaCell GXL......................................................60
XM2-HP................................................................ 18
AlphaCell GXL Runtime........................................61
XM2...................................................................... 19
AlphaCell..............................................................62
XM2-300HP.........................................................20
AlphaGuard™........................................................63
APB...................................................................... 21
Battery Testing Equipment...................................63
®
Smart Pack........................................................... 21
APX.......................................................................22
APP.......................................................................23
>Fiber Power
65-69
FlexPoint 12Vdc, RFoG.......................................66
™
FlexPoint AX 12Vdc, PON.....................................67
>Status Monitoring
25-31
FlexNet™ 48Vdc 50W............................................68
AlphaNet™ DSM3 Family for XM2.........................26
FlexNet 48Vdc 150W............................................68
AlphaNet DSM3 Family for XM3-HP....................27
FlexNet 48Vdc 300W...........................................69
3
AlphaNet IDH4 for XM2........................................28
>Wireless and Fiber Backhaul
71-75
AlphaNet EDH4....................................................30
Flexible Backhaul Enclosure 2322.......................72
Continuity Software.............................................. 31
Flexible Backhaul Enclosure 2319........................73
Flexible Backhaul Enclosure 1417V......................73
>Enclosure Systems
33-49
Wireless Transport Enclosure............................... 74
MDU and Fiber Deep System..............................34
Tempest Te45 Backhaul Enclosure...................... 74
LPE Enclosure......................................................35
Tempest Te40 Backhaul Enclosure...................... 75
Node Power System............................................36
Tempest Te41 Backhaul Enclosure...................... 75
NPS Enclosure.....................................................37
PWE Enclosure.....................................................38
UPE and UPE-M Enclosures................................39
Extended Runtime Enclosures.............................40
Enclosure Accessories......................................... 41
Security Enclosure Accessories...........................42
HSHP Enclosure ..................................................43
Powernode Systems............................................44
Fibernode Power Enclosure.................................46
Surge Protection...................................................48
Precast Pads........................................................49
Pedestal Support Series......................................49
Table of Contents
AlphaNet IDH4 for XM3-HP..................................29
Total Power Solutions
>Complete System Solutions
Systems engineered to work together are more efficient and more reliable. Alpha provides you
complete systems to serve every point of your cable broadband network, as well as options for
integrating renewable energy or Hybrid Power Systems into your operations. From power supplies and
batteries to solar modules and turn-key buildings, our powering systems are fully integrated for
maximum reliability and carefully engineered to minimize your total cost of ownership.
>Installation and Construction Services
With a national network of contractors, project managers and Alpha technicians, we can provide
turn-key solutions for outside plant, headend, telecommunications, industrial and renewable energy
applications. We work to combine your small-, medium- and large-scale projects with the necessary
installation resources. Our complete installation and facility construction services include structure
engineering, right-of-way and easement procurement, site preparation, equipment installation, utility
hook-up coordination, system turn-up and system testing.
>Preventative Maintenance
An on-going Preventative Maintenance program helps ensure optimum system reliability and
equipment life. Alpha's service plan options include performing routine scheduled maintenance, testing
of local and remote alarm operations and analyzing local data for Outside Plant, Headend
and Critical Facility Operations.
>Repairs, Refurbishments and Factory Upgrades
5
Featuring an on-site CableUPS® inverter module exchange, our goal is to maintain network uptime to
provide access to quick and stress-free system repairs and refurbishment options for all network
and improvement of all Alpha and third-party equipment including cable power supplies, RF line gear,
Headend, fiber and test equipment.
>On-Site Service
Alpha's state-of-the-art repair depots are strategically located across North America, and provide
convenient pick-up and drop-off services. In addition to regularly scheduled driving routes, we offer
preventative maintenance programs and emergency response capabilities where trained Alpha field
technicians can be dispatched 24 hours a day in specially equipped and service vehicles.
>Technical Support and Customer Service
Communication networks are operate 24 hours a day, so we offer around-the-clock telephone
technical support and web-based tools to generate RMAs and track open repairs, history and billing.
>Our ISO 14001:2004 Environmental Management System
Alpha strives to continually improve our Environmental Management System by benchmarking
opportunities for improving our performance and demonstrating conformity to system requirements.
We are committed to being industry and community leaders for sustainable business processes by
meeting legal/other requirements, communicating with internal/external customers and protecting our
environment through the implementation of sustainable business processes and preventing pollution
from occurring through our product design and daily practices.
Total Power Solutions
equipment. Our repair and development laboratories are designed for product repair, refurbishment
System Solutions
>Fully integrated powering systems to protect your network
>Next generation power solutions for emerging topologies
>Power conditioning and back-up from Headend to home
>Complete line of system accessories to maximize
reliability, efficiency and system runtime
We specialize in engineering complete network power
systems committed to reliability, OpEx savings and
environmental sustainability.
Total Power Solutions
6
We understand that systems engineered to work together are
more efficient and more reliable. As a result, we provide complete
systems serving every point of the cable broadband network, as
well as options for integrating renewable energy or hybrid power
systems into your operations. From power supplies and batteries
to solar modules and turn-key buildings, Alpha's powering
systems are fully integrated for maximum reliability and carefully
engineered to minimize total cost of ownership.
We are proud to have served the telecommunications industry
for more than 35 years, and we invite you to learn how we
can strengthen your entire network with Alpha Power.
High performance outside plant systems include multiple power supply, enclosure
and battery options, as well as a full line of system accessories for climate-specific
applications to provide extended runtimes and protect your powering investments.
Our RFoG and GPON Fiber Power Systems provide the same reliability as our HFC systems with
added features including outdoor access to batteries and multiple configuration options.
Heavy-duty reinforced concrete equipment structures can be outfitted to your custom
need, including back-up power, power conditioning, climate control, security and
communications, as well as on-site calibration and preventative maintenance programs.
Installation and Construction Services
>Complete design, engineering, permitting, construction and commissioning
>Headends, equipment shelters and other critical facilities
>Turn-key installation, turn-up and test services
>Grid-Tied and Off-Grid Renewable Energy Systems
7
Grid-Tied solar power can help minimize operating expenses and reduce your carbon footprint.
(153kW Grid-Tied system in Phoenix, AZ)
Off-Grid Solar and Hybrid Power Systems can provide the necessary redundancy for critical loads and
help extend network signal to remote areas. (11kW Off-Grid Hybrid Power System in Southwest Colorado)
Total Power Solutions
Alpha project managers will complete all site surveys, geological testing, engineering drawings and building permit applications.
Our nationwide network of contractors and project managers then coordinate the entire implementation on-site, from concept to commissioning.
Preventative Maintenance
>Develop historical data files for each
power system component
>Complete preventative maintenance checklists
>Perform mechanical maintenance
>Check accuracy of monitoring system
readouts and alarm set points
>Document routine service or call outs
Alpha’s field service technicians perform routine maintenance and emergency repair services for Outside Plant, Headend and Critical
Facility operations. Network hardware upgrades and critical plant hardening programs are also available.
Preventative Maintenance Services
An on-going Preventative Maintenance program helps ensure optimum system reliability and equipment life. Alpha’s service plan
options include performing routine scheduled maintenance, testing of local and remote alarm operations and analyzing local data.
Total Power Solutions
8
Preventative Maintenance
>Battery expansion cabinet installation
>Fixed and portable generator systems
>DOCSIS transponder installation
>Surge suppression & battery balancing
Plant Hardening Programs
With the necessary manpower and logistics to extend the life of your power networks, Alpha offers multiple plant hardening services for
Outside Plant, Headend and Critical Facilities operations.
9
Total Power Solutions
Repairs and Refurbishments
Full Service Repair for All Broadband Equipment
>40 Years experience in RF Line gear, Headend, Fiber and Test Equipment Repair
>All RF Repairs are certified using a fully loaded Digital QAM Spectrum
Power Supply Refurbishments and Factory Upgrades
>Immediate On-site Power Supply Inverter Module Exchange
>Refurbishment features include:
• Replacement of all Capacitors
• 2 or 3 year warranty of complete Power Supply
• Implementation of engineering changes to improve reliability
>Options to upgrade to embedded DOCSIS status monitoring
Total Power Solutions
10
Automated test equipment is used to efficiently verify all functions of refurbished power supplies.
Customer-requested and factory-recommended
improvements are implemented at time of service.
Refurbished equipment is put through a rigorous
burn-in cycle to identify marginal components.
Extensive experience repairing and refurbishing all telecommunications network equipment
including Cable Power Supplies, RF Line gear, Headend, Fiber and Test Equipment.
Customer Service
On-site Personal Service
>Free pick up and delivery on National Route Service
>Reduced freight costs for best overall service
Web Based Online Management Tools
>Create RMA requests
>Track open repairs, repair history and billing history
Track all aspects of your repairs online or call one of
our customer service representatives.
11
24/7 phone support available when you need it.
Burnaby, British Columbia
Mississauga, Ontario
Bellingham, Washington
Elk Grove Village, Illinois
Pennsauken, New Jersey
Aiken, South Carolina
Phoenix, Arizona
Dallas, Texas
Suwanee, Georgia
Jacksonville, Florida
Alpha Technologies Service Depot Locations across North America offer convenient pick-up and drop-off services.
Total Power Solutions
Routine maintenance programs ensure system reliability.
CableUPS® Power Supplies
Alpha has provided specialized uninterruptible power supplies (UPS) for more than 35 years.
With impressive backup power capabilities, integrated generators, dual power grid switching and
enhanced battery thermal management, an Alpha CableUPS ensures reliability and efficiency in
your broadband network.
>XM3-HP
Alpha’s XM3-HP CableUPS is the most innovative and intuitive solution to address the ever-increasing
power demands of today’s sophisticated communication networks. The XM3-HP features the highest
line mode and inverter efficiency with the tightest output voltage regulation, leading to decreased utility
power consumption and improved overall network performance. Advanced battery management
further optimizes battery life and reduces on-going operational costs by regulating current and charge.
The XM3-HP features embedded DOCSIS® Communications and Alpha Applications which provide
advanced intelligence diagnostics enabling remote management of the power network.
>XM2-HP
Alpha’s XM2-HP CableUPS is optimized to address the higher energy costs associated with running
today’s cable networks. The XM2-HP features a high efficiency transformer with lower power
consumption and lower life cycle costs. This “green” power supply can greatly reduce the carbon
footprint of the entire cable plant by running more efficiently 24/7. Additional features include an
enhanced Smart Display with improved menus and a dedicated Communications menu with DOCSIS
parameters. The XM2-HP is available in three convenient power ratings for load matching to operate
at optimal efficiency.
13
>XM2
it an ideal match for network architectures worldwide. Advanced product design features include
a hot-swappable modular inverter and Smart Display. Optional independent dual outputs and N+1
redundant capability provide additional protection and enhanced system reliability. AC or DC generator
compatibility, flexible system control and advanced status monitoring options support easy migration
to clustered or centralized powering.
>XM2-300HP
The XM2-300HP is the ideal CableUPS solution for rapidly expanding cable broadband networks
and services. When used in applications requiring less power than traditional outside plant powering,
you will experience increased efficiency and reduced operating costs. This 300 Watt power system
features a much smaller footprint and is engineered for use in multiple dwelling units (MDU), business
parks and node segmentations, as well as Fiber Deep, N+0 and N+1 plant extensions. Rated at
300 Watts, with a 12V inverter, this power supply features an XM2 Smart Display and an optional
DOCSIS-based status monitoring card.
>APX
Alpha’s APX is designed for communication networks that require compact, non-standby
power supplies. The APX’s ferroresonant design provides fully regulated output voltage, surge
and short-circuit protection. The APX can be easily upgraded by adding modular plug-in options
such as a Lightning Arrestor, Time Delay Relay, Ammeter, Status Indicator LED or AmpClamp™
Surge Suppressor.
>APP
The APP is a portable non-standby power supply used to provide conditioned AC power to
the load when the main power supply is being serviced. Used in conjunction with the "Alternate"
connector and the "ALT/ON" switch located on the enclosure's service power inserter, power can
be transferred from the main power module to the APP without interrupting the connected load.
Cable Power Supplies
Alpha’s XM2 CableUPS is the industry’s leading power technology. A variety of power ratings make
XM3-HP
CableUPS® Power Supply
Advanced Efficiency Technology
The Alpha XM3-HP triple efficiency ferro
technology optimizes the power supply’s
performance resulting in significantly reduced
utility power consumption and a direct savings
in network operating costs.
Exclusive, Patent-Protected Transformer Design.
>
Highest Line Mode Efficiency
The XM3-HP offers the highest line mode efficiency
available, requiring less AC utility power to support a load.
Utility
Power =
(kW)
Cable Power Supplies
14
(
P Network
Load
Cable Power Loss—I2R
+ ∑ [(
P @ Active
V @ Active
2
)
X
Ω
Feet
of cable
X
Feet
]
Distance
Power Supply Efficiency
> Tightest Output Voltage Regulation
Alpha’s XM3-HP provides the tightest output voltage regulation
ever offered to reduce I2R cable power losses.
>
Maximum Inverter Efficiency
Significant gains in inverter efficiency directly translates into increased battery runtimes,
further improving network performance and power outage recovery capabilities.
Available Models
Load Optimization: The XM3-HP is available in 8, 10, 15 and 18 Amp models to best match network load requirements.
ALPHA XM3-908HP
Guide for Optimal Efficiency
ALPHA XM3-910HP
ALPHA XM3-915HP
ALPHA XM3-918HP
0
2
4
6
8
10
AMPS
12
14
16
18
Maximum Efficiency
)
XM3-HP
CableUPS® Power Supply
Advanced Battery Management
The Alpha XM3-HP’s advanced battery management
optimizes battery life and contributes to both reducing
capital expenditures and on-going operating costs.
Embedded Battery Balancing
12.66Vdc
1200mA
1300mA
2500mA
>
14.00Vdc
13.87Vdc
The Alpha XM3-HP supports the embedded AlphaGuard uses advanced battery balancing technology to re-direct current
Optimal Float Voltage is 13.62Vdc at 25°C / 77°F
from overcharged batteries to the undercharged battery, optimizing battery service life.
-
Battery Charger
40.86Vdc
Float Voltage
AlphaGuard — Balancing
14.00Vdc
AlphaGuard — Balanced
1200mA
1300mA
2500mA
12.66Vdc
+
13.87Vdc
+
13.62Vdc
13.62Vdc
13.62Vdc
40.86Vdc
Float Voltage
300mA
>
300mA
300mA
300mA
13.62Vdc
13.62Vdc
Dynamic Multi-Stage Charging
The Alpha XM3-HP's dynamic 5-stage battery charging technology
13.62Vdc
provides system batteries with optimal charge management.
Batteries are balanced within ±0.1Vdc and the Float current
across each battery is equal. 13.62Vdc Float @ 25°C / 77°F
- Battery Charger +
Refresh • Bulk • Accept • Float • Rest
40.86Vdc
Float Voltage
>
Advanced AlphaCell® Battery Technology
Extended Runtime
The XM3-HP’s advanced battery management and increased inverter
efficiency maximizes battery runtime in the network.
XM3 AlphaCell® Typical Runtime (minutes)
6A
15
Cable Power Supplies
Battery Charger
40.86Vdc
Float Voltage
300mA
Batteries are balanced within ±0.1Vdc and the Float current
across each battery is equal. 13.62Vdc Float @ 25°C / 77°F
- Battery Charger +
Optimal Float Voltage is 13.62Vdc at 25°C / 77°F
-
300mA
90Vac @
4A
Model:
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
8A
4.0HP
3.5HP
10A
4.0HP
3.5HP
12A
4.0HP
3.5HP
14A
4.0HP
3.5HP
16A
3 Batteries:
540
588
358
394
263
295
204
234
165
193
137
164
116
142
6 Batteries:
1144
1264
771
841
574
624
450
491
368
404
308
342
264
295
Model:
195GXL
220GXL
195GXL 220GXL 195GXL
220GXL
195GXL
220GXL
195GXL
220GXL
195GXL
220GXL
195GXL
220GXL
3 Batteries:
476
550
313
363
229
265
177
205
142
164
118
136
99
115
6 Batteries:
1026
1177
685
789
506
585
396
458
322
373
269
311
229
266
4.0HP
XM3-HP
CableUPS® Power Supply
Advanced Intelligence Platform
The Alpha XM3-HP's internal intelligence provides
Network Operation Centers (NOC) with the critical
and highly relevant data necessary to reduce
operating expenses through remote management
of the power network.
>
Embedded DOCSIS® Communications.
The XM3's AlphaNet™ Integrated DOCSIS Communications Platform enables access to all of the XM3's advanced information
and diagnostics through a standard (SNMP) network interface.
DOCSIS® Communications Menu
COMM – GENERAL
CM MAC ADDRESS
COMM – GENERAL
CM IP ADDRESS
h
16
i
COMM – GENERAL
CM RECEIVE POWER
192.168.1.120
00:90:EA:00:36:EA
h
ESC
MAC Address
i
COMM – GENERAL
CM TRANSMIT POWER
9.8dBmV
ESC
h
i
IP Address
39.0dBmV
h
ESC
i
ESC
Receive and Transmit Power Levels
>
> 3 Hours
Embedded Alpha Applications.
2-3 Hours
1-2 hrs
< 1 Hr
Calculating
Not Available
Power reliability algorithms use real-time data to predict service intervals and battery replacements.
Enter Battery Date Code
& MHOs Reading
BATT
A1
hi
DATE
Battery Health
Battery Remaining Runtime
Battery Expected Life
Network Power Backup Capacity
1/10
ENTR
h
i
ESC
2-3 Hours
1-2 hrs
< 1 Hr
Calculating
Not Available
Battery Expected Life
Utility Performance Reports
Battery MHOs Trending
Utility Performance Reports
Total Power Supplies = 1600 • North American MSO
4.0%
> 3 Hours
< 1 Year
1-2 Years
2-3 Years
3-5 Years
> 5 Years
Adjust Value
ENTR to shift field
Site #028A1B1 Historical Conductance Analysis Report AlphaCell 195GXL < 1 Year
1-2 Years
2-3 Years
3-5 Years
> 5 Years
1400
3.5%
Freq Shifts
2.5%
Surges
1200
Sags
Battery A1
Battery A2
Battery A3
1000
Healthy
3.0%
Outages
1.6%
600
1.0%
400
0.5%
200
0.0%
January
February
March
April
May
June
0
PM Recommended
800
Replace
2.0%
MHOs
Precent of Power Supplies Affected
Cable Power Supplies
Network Power Backup Capacity
2012
2013
2014
2015
2016
2017
2018
XM3-HP
CableUPS® Power Supply
>Improved efficiency levels
>Optimized network performance
>Reduced operating costs and
total cost of ownership
XM3-HP CableUPS
XM3-HP
Models
908HP
910HP
915HP
918HP
Nominal AC Input Voltage:
120Vac
120Vac
120Vac, 240Vac
120Vac
Nominal Input Frequency:
60Hz
60Hz
60Hz
60Hz
Input Frequency Tolerance (%):
±3
±3
±3
±3
Input Voltage Operating
Range Tolerance (%):
-25 / +15
-25 / +15
-25 / +15
-25 / +15
Input Voltage Range (Vac):
90-138
90-138
90-138, 173-276
90-138
Output Voltage (Vac):
63 / 89
63 / 89
63 / 89
63 / 89
Output Voltage Regulation (%):
-2.5 / +1
-2.5 / +1
-2.5 / +1
-2.5 / +1
Maximum Rated
Output Current:
8 Amps
10 Amps
15 Amps
18 Amps
Maximum Output Power (VA):
720
900
1350
1620
Fine Mode Parameters
Standby Efficiency:
Up to 91%
Output Waveform:
Quasi-square wave
<150% of maximum current rating
Short Circuit Protection:
Uninterrupted output
Transfer Characteristics:
Battery Voltage (Vdc):
36
36
36
36
Battery Charger
Programmable (0 to 5mV/Cell/ºC)
Temperature Compensation:
10A
Bulk Charger Current:
Refresh, Bulk, Accept, Float, Rest
5 Stages:
Mechanical
Front plug in, Hot swappable inverter module
Inverter Module:
Dimensions
H x W x D (in/mm):
Weight (lb/kg):
Input Power Connector
(IEC 320/C20):
Battery Connector:
Remote Temp Sensor:
Display:
7.8 x 15 (16.7 w/handle) x 10 (10.7 w/handle) / 198.1 x 381 (424.18 w/handle) x 254 (271.8 w/handle)
48.5 / 22.0
NEMA 5-15P Plug
49 / 22.3
60 / 27.2
60.5 / 27.5
NEMA 5-15P Plug
NEMA 5-20P/
NEMA 6-15P Plug
NEMA 5-20P Plug
Anderson style 75A
Ring lug fastens to negative terminal on center battery
4 line by 20 character blue LCD with soft-key menu controls
Environment
Operating Temperature:
Humidity:
-40 to 60°C / -40 to 140°F (derate by 2ºC / 3.6°F per 1000 feet above 3000 feet)
0 to 95% non-condensing (relative)
Agency Compliance
Safety:
EMC:
CSA/UL 60950-1 (2nd), UL 1778 (4th) CSA No 107.3, C/US
FCC Part 15 Class A
Cable Power Supplies
Up to 94%
Line Mode Efficiency:
17
XM2-HP
CableUPS® Power Supply
>High efficiency transformer
>Features
Intelligent Inverter Module
>6, 18 and 24A models available
>Backwards compatible with XM2 CableUPS®
>Embedded and External DOCSIS® status monitoring
XM2-HP CableUPS
>Up to 15% more capacity than standard models
XM2-HP
Models
XM2-906HP
XM2-918HP
XM2-924HP
Input Voltage (Vac):
120/240
120/240
208/240
Input Voltage Window:
-30 to +20%
-20 to +15%
-20 to +15%
Input Frequency:
60Hz
60Hz
60Hz
Input Frequency Window:
±3Hz
±3Hz
±3Hz
Output Voltage (Vac):
63/87
63/75/87
63/75/87
Output Current (A):
8/6
22/18/18
22/22/24
Max Output Power (VA):
540
1620
Electrical
18
Voltage Regulation1:
Cable Power Supplies
2160
Quasi-square wave
Output Waveform:
Output
Frequency
Stability:
±5%
±5%
±5%
Line Mode
60Hz Nominal
Inverter Mode
60Hz, ±0.05%
<150% of maximum current rating
Short Circuit Protection:
Uninterrupted output
Transfer Characteristics:
Battery Voltage (Vdc):
36
36
48
Efficiency
(Typical Load Range)
Line Mode:
80-87%
90-92%
Standby Mode:
79-84%
84-86%
Battery Charger
Programmable (0 to 5mV/Cell/°C)
Temperature Compensation:
10A at 80% load and nominal input (bulk charge mode)
Charger Current:
Bulk, Accept, Float
Three Stage:
Mechanical
Status Display:
2 x 20 Blue LCD with backlight
Dimensions
H x W x D (in/mm):
8.8 x 15 x 13 / 222 x 381 x 330
Approx. Weight (lb/kg):
53 / 24
Finish:
72 / 32.7
95 / 42.9
Black, epoxy powdercoat
Environment
Operating Temperature:
Humidity:
Agency Compliance:
-40 to 55°C / -40 to 131°F
0 to 95% non-condensing
FCC Part 15 Class A, UL1778, CSA 22.2 No. 107.1
Optional Features
Standard Protective Interface Module (PIM/N+1): Provides two programmable outputs from a single XM2 CableUPS power supply for redundancy in critical applications.
The PIM protects system components and provides isolation between distribution legs by shutting down the individual load during over-current conditions.
Note:
1
Voltage regulation is maintained over both line and load ranges
XM2
CableUPS® Power Supply
>Proven CableUPS® uninterruptible power supply
>Features
Intelligent Inverter Module
>10, 15 and 22A models available
>Modular design with hot-swappable inverter
>Programmable, temperature-compensated battery charger
XM2 CableUPS
>Embedded and External DOCSIS status monitoring
®
XM2
Models
XM2-910
XM2-1350-48
XM2-915
XM2-915HV
XM2-922
XM2-922HV
Input Voltage (Vac):
120/240
120/240
120/240
120/240
208/240
240
Input Voltage Window:
-20 to +15%
-20 to +15%
-20 to +15%
-30 to +15%
-20 to +15%
-30 to +15%
Input Frequency:
60Hz
60Hz
60Hz
60Hz
60Hz
60Hz
Input Frequency Window:
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
±3Hz
Output Voltage (Vac):
63/75/87
63/75/87
63/75/87
63/75/89
63/75/87
63/75/89
Output Current (A):
10/10/10
22/15/15
15/15/15
20/17.5/15
22/22/22
22/22/22
Max Output Power (VA):
900
1350
1350
1350
2025
2025
±5%
±5%
48
48
Electrical
Quasi-square wave
Output Waveform:
Voltage Regulation:
±5%
±5%
±5%
±5%
Line Mode
60Hz Nominal
Inverter Mode
60Hz, ±0.05%
<150% of maximum current rating
Short Circuit Current:
Uninterrupted output
Transfer Characteristics:
Battery Voltage (Vdc):
36
48
36
36
Efficiency
(Typical Load Range)
Line Mode:
86-90%
Standby Mode:
82-85%
Battery Charger
Programmable (0 to 5mV/Cell/°C)
Temperature Compensation:
10A at 80% load and nominal input (bulk charge mode)
Charger Current:
Bulk, Accept, Float
Three Stage:
Mechanical
Status Display:
2 x 20 Blue LCD with backlight
Dimensions
H x W x D (in/mm):
8.8 x 15 x 13 / 222 x 381 x 330
Approx. Weight (lb/kg):
62 / 28.1
Finish:
70 / 31.8
70 / 31.8
72 / 32.7
92 / 41.7
96 / 43.5
Black, epoxy powdercoat
Environment
Operating Temperature:
Humidity:
Agency Compliance:
-40 to 55°C / -40 to 131°F
0 to 95% non-condensing
FCC Part 15 Class A, UL1778, CSA 22.2 No. 107.1
Optional Features
Standard Protective Interface Module (PIM/N+1): Provides two programmable outputs from a single XM2 CableUPS power supply for redundancy in critical applications.
The PIM protects system components and provides isolation between distribution legs by shutting down the individual load during over-current conditions.
Note:
1
Voltage regulation is maintained over both line and load ranges
Cable Power Supplies
Output
Frequency
Stability:
19
XM2-300HP
High Efficiency CableUPS®
>High efficiency 300W power supply
>XM2 programmable LCD Smart Display
>New predictive preventative maintenance features
>Small footprint and lightweight
>Ideal for RFoG, MDU and N+0 applications
>Embedded DOCSIS® status monitoring
XM2-300HP CableUPS
XM2-300HP
Model
XM2-300HP
Electrical
Cable Power Supplies
20
Input Voltage (Vac):
120
Input Voltage Window:
-15 to +10%
Input Frequency:
60Hz
Input Frequency Window:
±3Hz
Output Voltage (Vac):
60/87
Output Current (A):
5/3.5
Max Output Power (VA):
300
Output Waveform:
Sine wave
Voltage Regulation:
±5%
Output
Frequency
Stability:
Line Mode
60Hz Nominal
Inverter Mode
60Hz, ±0.05%
Short Circuit Protection:
150% for 10 seconds
Transfer Characteristics:
≤4ms
Battery Voltage (Vdc):
12
Efficiency
(Typical Load Range)
Line Mode:
93-94%
Standby Mode:
82-86%
Battery Charger
Temperature Compensation:
Programmable (0 to 5mV/Cell/°C)
Charger Current:
6A minimum - 10A maximum
Three Stage:
Bulk/Accept/Float
Mechanical
Status Display:
Blue smart display 2 x 20 LCD with backlight
Dimensions
H x W x D (in/mm):
8.5 x 9.75 x 8 / 216 x 248 x 203
Approx. Weight (lb/kg):
23 / 10.4
Finish:
Black, epoxy powdercoat
Environment
Operating Temperature:
-40 to 55°C / -40 to 131°F
Humidity:
0 to 95% non-condensing
Agency Compliance:
FCC Part 15 Class A, UL / CSA 60950-1, UL1778, UL1012 CSA C22.2 No. 107
Advanced Diagnostics
Advanced Analytics:
Onboard battery algorithm for predictive service required, Onboard inverter algorithm for predictive service required
User Inputs:
Power supply install and battery manufacturing dates, Power supply priority level, Siemens values during battery preventative maintenance cycles,
Battery out-of-date period, Battery heater mat installed (Yes/No), Technician code/ID
APB
APB HFC Voltage Booster
>Configurable for 90 or 60Vac output voltage
>High-efficiency auto transformation
>Intelligent overload protection
>Water-tight enclosure; wall or standard mounted
>Reverse connection protection
>Input surge protection
>Automatic bypass in the event of downstream network failure
Alpha Power Booster
APB
Specifications
Mechanical
Electrical
Dimensions H x L x D (in/mm):
9.13 x 14 x 6.75 / 232 x 356 x 171
Input Voltage:
45 to 65Vac 60Hz / 65 to 90Vac 60Hz
Weight (lb/kg):
21.4 / 9.7
Input Current:
10 Amps RMS (max.)
Environmental
Output Voltage:
36Vac 60Hz / 87Vac 60Hz
Output Current:
<8 Amps RMS (max.)
Output Rating:
Operating Temperature:
-40 to 65°C / -40 to 149°F
Storage Temperature:
-50 to 70°C / -58 to 158°F
650VA (max.)
Outdoor Rating:
Type 4 enclosure
Overload Protections*:
115% of max input current for 27 minutes*
Standard Compliance
Short Curcuit:
Bypass mode, automatic recovery
Overload Recovery:
Automatic
Surge Resistance:
6kV / 3000A (IEEE C61.45 part 15)
Efficiency:
>96% at 25 to 100% load
RF Freq Range:
5 to 1000MHz
RF Insertion Loss Maximum:
1.2dB (5 to 50MHz), 1.2dB (50 to 870MHz),
1.6dB (870 to 1000MHz)
Flatness:
±0.25dB (5 to 50MHz), ±0.35dB (50 to 870MHz),
±0.50dB (870 to 1000MHz)
RF Slope Maximum:
0.80dB (5 to 50MHz), -1.0dB (50 to 870MHz),
-1.25dB (870 to 1000MHz)
Hum Modulation:
<-68dB (5 to 1000MHz), (<-82dB freq. domain)
Return Loss Minimum:
17dB (5 to 1000MHz)
Electrical Egress:
<-120dBm (45 to 870MHz)
Isolation:
Neutral carries through
Safety:
CSA (C/US)
CAN/CSA C22.2 No. 60950-1-07
UL 60950-1, 2nd Edition
Note: * The APB is designed to open up an output relay and discontinue output during
extended periods of overload to protect vital components. Once this relay is open, the unit
will periodically attempt to close the relay to determine if the overload condition has ceased.
Dual Inverter Module Case
>Durable and lightweight case
>Antistatic cushioning to protect Inverter Modules
>Fits any combination of XM2 I2M or XM3 Inverters
>Discounted pricing when purchasing
case with Inverter Modules
>Extra space to store spare components
Smart Pack
Mechanical
9.6 x 21.3 x 14.3 / 243 x 541 x 363
Weight (lbs/kg):
Empty IM Case:
6.2 / 2.8
Case with Two I M:
20.8 / 9.5
2
Case with Two IM3:
17.4 / 7.9
Case with I2M and IM3:
19.2 / 8.7
Smart Pack Case
1: Spare component case, 2: Status monitors
Cable Power Supplies
High-efficiency autotransformer
Intelligent overload protection
Water-tight enclosure; wall or strand mounted
LED function indicator light on PCB for troubleshooting
Smart Pack
Dimensions
H x L x D (in/mm):
21
Standard Features
APX
Non-Standby Power Supply
>Complete line conditioning
>Modular transformer design
>Flexible mounting options
>Current limited output and short circuit protection
APX Series
APX
Models:
22
Input
Voltage (Vac)
Input
Frequency (Hz)
Output
Voltage (Vac)
Output
Current (A)
Max. Output
Power (VA)
Input Protection
(breaker)
Output
Protection (fuse)
Weight
(lb/kg)
APX 6008:
120
60
63
8
480
8A
10A
21 / 9.5
APX 6014:
120
60
63
14
840
12A
15A
30 / 13.6
APX 9015-120:
120
60
63/75/87
15
1350
12A
20A
47.5 / 21.6
APX 9015-240:
240
60
63/75/87
15
1350
12A
20A
47.5 / 21.6
APX 9015-120 HV:
120
60
63/75/89
15
1350
12A
20A
51 / 23
APX 9015-240 HV:
240
60
63/75/89
15
1350
12A
20A
51 / 23
APX 6008 RM:
120
60
63
8
480
8A
10A
22 / 10
APX 6014 RM:
120
60
63
14
840
12A
15A
31 / 14
Note: Other voltages and configurations may be available. For more information, contact your local Alpha sales representative.
Cable Power Supplies
Input
Mounting Options
Power Factor:
>0.90 at full load
Voltage Tolerance:
±15%
Voltage (APX 9015 HV):
-25 to 15%
Frequency:
±3%
Output
Waveform:
Quasi-square wave
Regulation:
±5%
Efficiency:
90% or better
Pole Mount (PM): Built of durable, weather-resistant, powdercoated aluminum to
withstand the harshest environments. This enclosure also includes brackets that
provide for easy bolted, or banded Pole Mounting.
Wall Mount (WM): Allows the module to be mounted on a flat, vertical surface.
Shelf Mount (SM): Allows the module to be mounted on flat, horizontal
surfaces such as the PWE or UPE enclosures. An extended input power
cable is also included.
Pedestal Mount (PED): Ideal for ground mount applications, and provides
weather-resistant, steel construction. The APX PED is available in either
concrete or soil mount versions (please specify at time of order).
Rack Mount (RM): Ideal for mounting the power supply in a standard 19" rack.
Mechanical
Dimensions H x W x D (in/mm)
APX 6008, 6014:
11.75 x 7.5 x 10.5 / 298 x 190 x 267
APX 9015:
15.5 x 8.5 x 11 / 394 x 216 x 279
Finish:
Gray, epoxy powdercoat
Enclosure Material:
Aluminum
Environment
Operating Temperature:
-40 to 55°C / -40 to 131°F
Agency Compliance:
UL1012/CSA C22.2 No. 107.1-M95
Optional Features
SIL-C:
Long life LED pilot light
LA-M:
Plug-In lightning arrestor (120V)
AMM-C:
Easy reading panel ammeter
TDR-M:
Time delay relay (10 to 60sec variable)
ACAT-3P:
Plug-In Amp Clamp™
GLK:
Enclosure security lock (PM)
APX - Cover removed
APP
Service Power Supply
>Portable service power supply
>Time proven ferroresonant technology
>Selectable input and output voltages
>15A and 22A versions available
APP9022S
APP
APP9015S
APP9022S
Input Voltage (Vac):
120/240 ±15%
120/240 ±15%
Input Current (A):
12
16/12 max.
Input Frequency:
60Hz
60Hz
Output Voltage (Vac):
60/75/87 ±5%
60/75/87 ±5%
Output Current (A):
15
17 (22 at 240Vac Input)
Output Power (VA)
(Continuous):
1350
1350/1650/2000
Output Current Limit:
150% of output rating
150% of output rating
Efficiency:
90% typical @ rated load
90% typical @ rated load
Agency Compliance:
—
CSA
Finish:
Black, epoxy powdercoat
Black, epoxy powdercoat
Operating Temperature:
-40 to 50°C / -40 to 122°F
-40 to 50°C / -40 to 122°F
Dimensions H x W x D (in/mm):
9 x 9.5 x 13.75 / 229 x 241 x 349
9 x 9.5 x 14.75 / 229 x 241 x 375
Weight (lb/kg):
47 / 21
60 / 27
23
Cable Power Supplies
Models:
APP Kits:
APP-9015S Kit Includes:
874-726-20 — Line Cord Assy, 120Vac, 5-20P, APP-9015S
874-727-20 — Line Cord Assy, 240Vac, 6-15P, APP-9015S
874-728-20 — Output Cable Assy, Jones Connector, APP-9015S
874-712-20 — WR KT, ADPTR, SPS JONES to SPI 25XM
APP-9022S Kit Includes:
874-935-20 — Line Cord Assy, 120Vac, 5-20P, APP-9022S
874-935-21 — Line Cord Assy, 240Vac, 6-15P, APP-9022S
All output cables for the APP-9022S are to be ordered as separate line items. One standard output cable kit (745-223-20) is included in the price of the APP-9022S.
Additional output cables or 30ft cable kits can be ordered (additional cost) as needed.
745-223-20 Kit Includes:
874-949-20 — Y-Cables, 25A Connectors, 6', APP-9022S
874-949-21 — Y-Cables, Jones, 6', APP-9022S
875-173-20 — Lectro Adapter, Lectro to APP-9022S
Cables:
874-726-20 (5-20 plug)
Power cord with 5-20P
plug (120Vac)
874-727-20 (6-15 plug)
Power cord with 6-15P
plug (240Vac)
874-728-20
Output cable, single Jones
875-173-20
25A Lectro Adapter
874-935-20 (5-20 plug)
Power cord with 5-50P
plug (120Vac)
874-935-21 (6-15 plug)
Power cord with 6-15P
plug (240Vac)
874-935-22
Optional 10-Ft cord with
30A connector and
Twist Lock Plug (125Vac)
874-949-20
Y cable with
25A connectors
874-949-21
Y cable with
Jones connectors
874-949-32
30-Ft cable
874-949-33
Y cable adapter for
25A connector
874-949-34
Y cable adaptor for
Jones connector
Status Monitoring
Monitoring, measuring and managing power supplies, batteries and generators are not easy tasks.
However, in order to maintain customer satisfaction, reduce operating costs and meet regulatory
requirements, you need specific information from your systems. Alpha’s status monitoring solutions
use state-of-the-art communications technology to transmit critical network performance data to the
headend or network management center. This allows you to be proactive and take corrective action
before serious problems occur. Whether you are extending the life of your network backup power
through battery balancing, managing QoS for VoIP services or monitoring for trouble areas during an
AC power outage, the AlphaNet™ series of products provides the tools to manage today’s network
power requirements with the ability to upgrade for tomorrow’s needs.
>AlphaNet DSM Series
The AlphaNet family of networking products, including the 3rd generation DOCSIS® Status Monitoring
broadband power communication card, enables Alpha’s XM3-HP, XM2-HP, XM2, XM2-300HP
and GMX CableUPS® to connect directly to an HFC network through an embedded DOCSIS
cable modem.
Through a Simple Network Management Protocol (SNMP) interface, standard MIBs are used for
quick, efficient network status and diagnostics. A Web interface enables any authorized personnel
direct access to powerful, advanced diagnostics using a common web browser. No proprietary
software is required. A single DSM installed in an Alpha CableUPS supports communications and
system control for multiple Alpha power supplies and an AlphaGen™ generator system.
>AlphaNet IDH Series
25
Alpha's IDH transponders from Cheetah Technologies combine the latest monitoring capabilities with
advanced features available through the Cheetah XD management platform.
Alpha's EDH4 by Cheetah Technologies enables legacy power supplies to be monitored using the
latest DOCSIS transponders.
>Continuity DOCSIS Power Supply Monitoring
Continuity-SPS (Standby Power Supply) is a flexible standby power supply status monitoring solution.
Based on HMS and DOCSIS standards, Continuity supports any standards-based transponder,
providing you with a centralized, feature-rich, web-enabled tool to monitor all the standby power
supplies in your network.
Status Monitoring
>AlphaNet External Transponders
AlphaNet™ DSM3 Family
DOCSIS® Status Monitor for XM2 Family, GMX and VMX
>Embedded network management for
Alpha broadband power supplies
>Battery and power supply advanced
diagnostics reduces truck rolls and overall
operating expense of maintaining a network
AlphaNet DSM3
>Three models available: DSM3 (standard),
DSM3x (advanced) and DPM (XM2-300HP)
AlphaNet DSM3x
AlphaNet DPM
AlphaNet DSM3 Family for XM2 Family, GMX and VMX
Power Supply Monitored Parameters
Specifications
26
Power Supply
Models Supported:
DSM3x and DSM3: XM2-HP, XM2-300HP, XM2, GMX, VMX
DPM: XM2-300HP
Major Alarm:
Battery Monitoring:
DSM3x: Up to four strings of 36 or 48V batteries, DSM3: Up
to two strings of 36 or 48V batteries, DPM: One 12V battery
Minor Alarm:
Power System Management
(DSM3x Only):
Up to five power supplies and an AlphaGen generator are
managed from a single DSM3x including coordinated battery
charging, system test and aggregated alarm
Management Protocol:
Standard ANSI/SCTE HMS MIBs support basic power supply
monitoring. Advanced diagnostics with battery and power
module analytics available via secure SNMP
Advanced Diagnostics
Status Monitoring
Intelligent Power
Supply Interface:
Power supply user interface displays advanced diagnostics
including: DOCSIS modem upstream and downstream RF
levels, IP address assigned by network DHCP server, MAC
address and firmware levels, individual battery voltages to
verify correct wire harness installation
Hardware
Aggregate alarm consisting of: test fail, battery fail, line
isolation alarm, output overload, inverter, over-temperature,
N+1 active, fuse fail
Aggregate alarm consisting of: temperature probe error, AC
line loss, N+1 error
Input Voltage:
Reported from power supply V(in) measurement
Output Voltage:
Reported from power supply V(out) measurement
Output Current:
DSM3x and DSM3: 0 to 25A standard on port 1. Ports 2-4
require power supply option. DPM: Dual outputs do not exceed
300 Watts combined 3.5 Amps at 90 Vac output voltage, 5
Amps at 60 Vac output voltage
Output Power:
Calculated, reported in AC Watts
UPS Status:
AC Line, Standby, Test in process, Test alarm
Enclosure Door:
Open or Closed
Battery Voltage:
DSM3x: Individual battery voltage, up to four strings of 3 or
4 batteries (maximum 16 batteries), ±100mV per battery.
DSM3: Individual battery voltage, up to two strings of 3 or 4
batteries (maximum 8 batteries), ±100mV per battery. DPM:
Individual battery voltage
Battery Temperature:
Reported from power supply battery Remote Temperature
Sensor (RTS)
Remote Test Control:
Start/Stop power supply test cycle
RF Cable Interface:
F-connector, female, 75 Ohm, connector angle accommodates
coax bend radius when installed in some enclosures
Local Interface:
RJ-45, Ethernet, multi-mode operation
Generator Monitored Parameters (DSM3x Only)
LED Indicators:
Ready/Alarm, Upstream registration, Downstream lock,
AlphaBus, RF level, Link, CPE traffic, Battery harness correct
Status:
Generator Off, Running, Alarm
I/O Control (DSM3x Only):
6-pin Molex: Digital input, Digital output, 5V, Common
Generator Alarm:
AlphaBus:
RJ-11 offset tab: Multi-power supply and AlphaGen
communications
Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel,
water intrusion, pad shear, gas hazard, test fail
Gas Hazard:
OK, Alarm
Battery Monitoring:
DSM3x: 8-pin Molex battery string A/B, 8-pin Molex battery
string C/D. DSM3: 8-pin Molex battery string A/B
Water Intrusion:
OK, Alarm
Pad Shear:
OK, Alarm
Tamper:
NO or NC, software configurable, reads enclosure door
magnetic switch
Enclosure Door:
Open, Alarm
Ignition Battery Voltage:
±100mV
Enclosure Temperature:
±2°C
Environment
Operating Temperature:
-40 to 65°C / -40 to 149°F
Low Fuel:
OK, Alarm
Storage Temperature:
-40 to 85°C / -40 to 185°F
Remote Test Control:
Start / Stop generator test cycle
Humidity:
10 to 90% non-condensing
Cable Modem
Compliance:
DOCSIS 1.1 and 2.0
EuroDOCSIS 2.0
Transmit Frequency Range:
5 to 42Mhz
5 to 65Mhz
Regulatory Compliance:
FCC Part 15 Class A
EN 50083-2:2006 EMC requirements for CATV equipment
EN 62040-2:2006 Uninterruptible power supply
EMC requirements, Category C2
Surge: IEEE 587, Category B3
RoHS: Directive 2002/95/EC
Receive Center Frequency Range:
91 to 857Mhz
112 to 858Mhz
Output Power Range:
TDMA:
+8 to +54dBmV (32QAM, 64QAM)
+8 to +55dBmV (8QAM, 16QAM)
+8 to +58dBmV (QPSK)
S-CDMA:
+8 to +53dBmV
(All modulations of S-CDMA)
TDMA:
+68 to +114dBuV (32QAM, 64QAM)
+68 to +115dBuV (8QAM, 16QAM)
+68 to +118dBuV (QPSK)
S-CDMA:
+68 to +113dBuV
(All modulations of S-CDMA)
Input Signal Range:
-15 to 15dBmV
64QAM: 43 to 73dBuV
256QAM: 47 to 77dBuV
Channel Bandwidth:
6Mhz
8Mhz
Network Communications
DOCSIS (RF) Port Protocols:
IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP
Ethernet Port:
Local Mode: HTTP web interface for local on-site diagnosis
CPE Mode: DOCSIS Cable modem Ethernet CPE functionality
MIBs:
Power supply (ANSI/SCTE 38-4)
Other SCTE HMS MIBs as defined by the SCTE for power
supply and generator status monitoring
Alpha proprietary advanced UPS diagnostics
Additional Equipment
XP-BSC-3-6:
Wire Kit, Battery Sense, 1x36V, 6'
XP-BSC-6-6:
Wire Kit, Battery Sense, 2x36V, 6'
XP-BSC-4-6:
Wire Kit, Battery Sense, 1x48V, 6'
Surge Arrestor
(Alpha P/N 162-028-10):
Female/Female connector configuration, "F"-type connector
with integral ground block required for all installations
AlphaNet™ DSM3 Family
DOCSIS ® Status Monitor for XM3-HP Series
>Embedded network management for
Alpha broadband power supplies
>Three models available: DSM3 (standard),
DSM3x (advanced) and DPM (used
with Smart AlphaGuard option)
AlphaNet DSM3
AlphaNet DSM3x
AlphaNet DPM
AlphaNet DSM3 Family for XM3-HP Series
Power Supply Monitored Parameters
Specifications
Power Supply Models Supported:
DSM3, DSM3x and DPM: XM3-HP Series
Major Alarm:
Battery Monitoring:
DSM3: Up to two strings of 36V batteries, DSM3x: Up to
four strings of 36V batteries, DPM: Up to four strings of 36V
batteries with Smart AlphaGuard Option (SAG)
Aggregate alarm consisting of: test fail, battery fail, line isolation,
output failure, output overload, output tripped, charger failure,
inverter temperature, configuration error, inverter failure, no
batteries, battery failure
Power System Management
(DSM3x Only):
Up to five power supplies and an AlphaGen generator are
managed from a single DSM3x including coordinated battery
charging, system test and aggregated alarm
Minor Alarm:
Aggregate alarm consisting of: AC line loss, input over current/
input current limit, surge MOV failure, inverter enable, option
board failure, battery temperature probe
Input Voltage:
Reported from power supply V(in) measurement
Output Voltage:
Reported from power supply V(out) measurement
Management Protocol:
Standard ANSI/SCTE HMS MIBs support basic power supply
monitoring. Advanced diagnostics with battery and power
module analytics available via secure SNMP
Output Current:
0 to 25A standard on port 1, port 2 requires power supply option
Output Power:
Calculated, reported in AC Watts
Input Current:
Reported in Amps
Input Power:
Reported in AC Watts
UPS Status:
AC Line, Standby, Test in process, Test alarm
Charger Current:
Reported in Amps
Battery Discharge Current:
Reported in Amps
Battery Voltage:
DSM3x: Individual battery voltage, up to two strings of 3 or 4
batteries (maximum 8 batteries), ±100mV per battery. DSM3:
Individual battery voltage, up to four strings of 3 or 4 batteries
(maximum 16 batteries), ±100mV per battery. DPM: Individual
battery voltage, up to two strings of 3 or 4 batteries (maximum 8
batteries), ±100mV per battery. Requires SAG option
Battery Temperature:
Reported from power supply battery Remote Temperature
Sensor (RTS)
Remote Test Control:
Start/Stop power supply test cycle
Enclosure Door:
Open or Closed
Advanced Diagnostics
Intelligent Power
Supply Interface:
Power supply user interface displays advanced diagnostics
including: DOCSIS modem upstream and downstream RF
levels, IP address assigned by network DHCP server, MAC
address and firmware levels
Power supply internal analytic dignostics report when batteries
should be serviced.
• Battery String Runtime Remaining
• Battery Life Remaining
Utility Status and Events
(Requires AlphaApps Option):
AC Line Status:
• Utility Performance Status (outages, sags, surges, frequency)
• Utility Events (24-hour and lifetime number of events)
History Log Reports:
• Power Supply Event Log
(events of daily power supply operation)
• Power Supply Configuration Log
(events that occur infrequently)
• Battery Event Log (battery conductance measurements
and battery manufactured dates)
Hardware
Generator Monitored Parameters (DSM3x Only)
Status:
Generator Off, Running, Alarm
Generator Alarm:
Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel,
water intrusion, pad shear, gas hazard, test fail
RF Cable Interface:
F-connector, female, 75 Ohm, connector angle accommodates
coax bend radius when installed in some enclosures
Gas Hazard:
OK, Alarm
Local Interface:
RJ-45, Ethernet, multi-mode operation
Water Intrusion:
OK, Alarm
LED Indicators:
Ready/Alarm, Upstream registration, Downstream lock,
AlphaBus, RF level, Link, CPE traffic, Battery harness correct
Pad Shear:
OK, Alarm
Enclosure Door:
Open, Alarm
I/O Control (DSM3x Only):
6-pin Molex: Digital input, Digital output, 5V, Common
Ignition Battery Voltage:
±100mV
AlphaBus:
RJ-11 offset tab: Multi-power supply and
AlphaGen communications
Enclosure Temperature:
±2°C
DSM3x: 8-pin Molex battery string A/B, DSM3: 8-pin Molex
battery string A/B and 8-pin Molex battery string C/D
Low Fuel:
OK, Alarm
Remote Test Control:
Start / Stop generator test cycle
Battery Monitoring:
Tamper:
NO or NC, software configurable, reads enclosure door
magnetic switch
Environment
Operating Temperature:
-40 to 65°C / -40 to 149°F
Storage Temperature:
-40 to 85°C / -40 to 185°F
Humidity:
10 to 90% non-condensing
Regulatory Compliance:
FCC Part 15 Class A
EN 50083-2:2006 EMC requirements for CATV equipment
EN 62040-2:2006 Uninterruptible power supply
EMC requirements, Category C2
Surge: IEEE 587, Category B3
RoHS: Directive 2002/95/EC
Network Communications
DOCSIS (RF) Port Protocols:
IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP
Ethernet Port:
Local Mode: HTTP web interface for local on-site diagnosis
CPE Mode: DOCSIS Cable modem Ethernet CPE functionality
MIBs:
Power supply (ANSI/SCTE 38-4)
Other SCTE HMS MIBs as defined by the SCTE for power
supply and generator status monitoring
Alpha proprietary advanced UPS diagnostics
Cable Modem
Compliance:
DOCSIS 1.1 and 2.0
EuroDOCSIS 2.0
Transmit Frequency Range:
5 to 42Mhz
5 to 65Mhz
Receive Center Frequency Range:
91 to 857Mhz
112 to 858Mhz
Output Power Range:
TDMA:
+8 to +54dBmV
(32QAM, 64QAM)
+8 to +55dBmV
(8QAM, 16QAM)
+8 to +58dBmV (QPSK)
S-CDMA:
+8 to +53dBmV
(All modulations of S-CDMA)
TDMA:
+68 to +114dBuV
(32QAM, 64QAM)
+68 to +115dBuV
(8QAM, 16QAM)
+68 to +118dBuV (QPSK)
S-CDMA:
+68 to +113dBuV
(All modulations of S-CDMA)
Input Signal Range:
-15 to 15dBmV
64QAM: +43 to +73dBuV
256QAM: +47 to +77dBuV
Channel Bandwidth:
6Mhz
8Mhz
Additional Equipment
XP-BSC-3-6:
Wire Kit, Battery Sense, 1x36V, 6'
XP-BSC-6-6:
Wire Kit, Battery Sense, 2x36V, 6'
XP-BSC-4-6:
Wire Kit, Battery Sense, 1x48V, 6'
Surge Arrestor
(Alpha P/N 162-028-10):
Female/Female connector configuration, "F"-type connector
with integral ground block required for all installations
Status Monitoring
Battery State of Health
(Requires AlphaApps Option):
27
AlphaNet™ IDH4
DOCSIS® Status Monitor for XM2 Family, GMX & VMX
>Embedded network management for Alpha
brodband power supplies
>Standard network interface Web access and
SNMP ANSI/SCTE HMS MIBs
>Integrated network diagnostics tools
>Three models available: IDH4 (standard),
IDH4x (advanced) and IDH4L (XM2-300HP)
AlphaNet IDH4
AlphaNet IDH4x
AlphaNet IDH4L
AlphaNet IDH4 for XM2 Family, GXM & VMX
Power Supply Monitored Parameters
Specifications
Power Supply
Models Supported:
IDH4: XM2-HP, XM2, GXM, VMX, IDH4x: XM2-HP, XM2, GXM,
VMX, IDH4L: XM2-300HP
Battery Monitoring:
IDH4: Up to two strings of 36 or 48V batteries (6V batteries
configurable up to two strings), IDH4x: Up to four strings of 36
or 48V batteries (6V batteries configurable up to four strings),
IDH4L: One 12V battery (or two if AlphaCell Batteries)
Power System Management:
IDH4: N/A, IDH4x: Up to five power supplies and an AlphaGen
generator are managed from a single IDH4x including
coordinated battery charging, system test and aggregated
alarms, IDH4L: N/A
Advanced Diagnostics
28
Intelligent Power
Supply Interface:
Power supply user interface displays advanced diagnostics
including: DOCSIS modem upstream and downstream RF
levels, IP address assigned by network DHCP server, MAC
address and firmware levels, individual battery voltages to verify
correct wire harness installation
Power Inverter State of Health:
Power Supply internal diagnostics report if the power inverter
requires service. Reported Values: Inverter OK, Replace Inverter
Major Alarm:
Aggregate alarm consisting of: test fail, battery fail, line isolation
alarm, output overload, inverter, over-temperature, N+1 active,
fuse fail
Minor Alarm:
Aggregate alarm consisting of: temperature probe error, AC line
loss, N+1 error
Input Voltage:
Reported from power supply V(in) measurement
Output Voltage:
Reported from power supply V(out) measurement
Output Current:
IDH4 and IDH4x: 0 to 25A standard on port 1, Port 2-4
requires power supply option, IDH4L: Dual outputs not to
exceed 300 Watts; combined 3.5 Amps at 90Vac output
voltage, 5 Amps at 60Vac output voltage
Output Power:
Calculated, reported in AC Watts
UPS Status:
AC Line, Standby, Test in progress, Test alarm
Battery Voltage:
IDH4: Individual battery voltage, up to two strings of 3 or 4
batteries (maximum 8 batteries), ±100mV per battery, IDH4x:
Individual battery voltage, up to four strings of 3 or 4 batteries
(maximum 16 batteries), ±100mV per battery, IDH4L: Individual
battery voltage
Battery Temperature:
Reported from power supply battery Remote Temperature
Sensor (RTS)
Enclosure Door:
Open or Closed
Status Monitoring
Hardware
RF Cable Interface:
F-connector, female, 75 Ohm, connector angle accommodates
coax bend radius when installed in some enclosures
Local Interface:
RJ-45, Ethernet,10/100Mbps
LED Indicators:
Ready/Alarm, Upstream registration, Downstream lock,
AlphaBus activity, RF level, Ethernet Link, CPE traffic, Battery
Sense harness correctly connected
I/O Control (IDH4x and IDH4L Only):
6-pin Molex: Digital input, Digital output, 5V, Common
AlphaBus:
RJ-11 offset tab: Multi-power supply and
AlphaGen communications
Battery Monitoring:
IDH4: 8-pin Molex battery string A/B, IDH4x: 8-pin Molex battery
string A/B and 8-pin Molex battery string C/D, IDH4L: N/A
Tamper:
NO or NC, software configurable, reads enclosure door
magnetic switch
Environment
Operating Temperature:
-40 to 65°C / -40 to 149°F
Storage Temperature:
-40 to 85°C / -40 to 185°F
Humidity:
10 to 90% non-condensing
Regulatory Compliance:
FCC Part 15 Class A
EN 50083-2:2006 EMC requirements for CATV equipment
EN 62040-2:2006 Uninterruptible power supply EMC
requirements, Category C2
Surge: IEEE 587, Category B3
RoHS: Directive 2002/95/EC
Generator Monitored Parameters (IDH4x Only)
Status:
Generator Off, Running, Alarm
Generator Alarm:
Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel,
water intrusion, pad shear, gas hazard, test fail
Gas Hazard:
OK, Alarm
Water Intrusion:
OK, Alarm
Pad Shear:
OK, Alarm
Enclosure Door:
Open, Alarm
Ignition Battery Voltage:
±100mV
Enclosure Temperature:
±2°C
Low Fuel:
OK, Alarm
Remote Test Control:
Start / Stop generator test cycle
Cable Modem for DOCSIS 1.1 and 2.0
Transmit Frequency Range:
5 to 42Mhz
Receive Center Frequency Range:
91 to 857Mhz
Output Power Range:
TDMA:
+8 to +54dBmV (32QAM, 64QAM)
+8 to +55dBmV (8QAM, 16QAM)
+8 to +58dBmV (QPSK)
S-CDMA:
+8 to +53dBmV (All modulations of S-CDMA)
Network Communications
DOCSIS (RF) Port Protocols:
IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP, SNTP
Ethernet Port:
Local Mode: HTTP web interface for local on-site diagnosis
CPE Mode: DOCSIS Cable modem Ethernet CPE functionality
Input Signal Range:
-15 to 15dBmV
Channel Bandwidth:
6Mhz
Additional Equipment
MIBs:
Power supply (ANSI/SCTE 38-4)
Other SCTE HMS MIBs as defined by the SCTE for power
supply and generator status monitoring
Alpha proprietary advanced UPS diagnostics
874-842-21 (P/N):
Wire Kit, Battery Sense, 1x36V, 6'
874-842-20 (P/N):
Wire Kit, Battery Sense, 2x36V, 6'
874-841-21 (P/N):
Wire Kit, Battery Sense, 1x48V, 6'
874-841-20 (P/N):
Wire Kit, Battery Sense, 2x48V, 6'
162-028-10 (P/N):
Surge Protector: Female/Female conector configuration, "F"
type connector with integralf ground block required for all
installations
AlphaNet™ IDH4
DOCSIS® Status Monitor for XM3-HP
>Embedded network management for Alpha
brodband power supplies
>Standard network interface Web access and
SNMP ANSI/SCTE HMS MIBs
>Integrated network diagnostics tools
>Three models available: IDH4 (standard), IDH4x
(advanced) and IDH4L (used with AlphaGuard option)
AlphaNet IDH4
AlphaNet IDH4x
AlphaNet IDH4L
AlphaNet IDH4 for XM3-HP
Power Supply Monitored Parameters
Specifications
Power Supply Models Supported:
XM3-HP
Battery Monitoring:
IDH4: Up to two strings of 36 or 48V batteries (6V batteries
configurable up to two strings), IDH4x: Up to four strings of 36
or 48V batteries (6V batteries configurable up to four strings),
IDH4L: N/A
Power System Management:
IDH4: N/A, IDH4x: Up to five power supplies and an AlphaGen
generator are managed from a single IDH4x including
coordinated battery charging, system test and aggregated
alarms, IDH4L: N/A
Management Protocol:
Standard ANSI/SCTE-HMS MIBs support basic power supply
monitoring. Advanced diagnostics with battery and power
module analytics available via secure SNMP
Advanced Diagnostics
Major Alarm:
Aggregate alarm consisting of: test fail, line isolation alarm,
output failure, output overload, output tripped, charger failure,
inverter temperature, configuration error, inverter failure, no
batteries, battery failure
Minor Alarm:
Aggregate alarm consisting of: AC line loss, input over current/
input current limit, surge MOV failure, inverter enable, charger
enable, option board failure, battery temperature probe
Input Voltage:
Reported from power supply V(in) measurement
Output Voltage:
Reported from power supply V(out) measurement
Input Current:
Reported in Amps
Output Current:
0 to 25A standard on port 1, Port requires power supply option
Input Power:
Reported in AC Watts
Output Power:
Calculated, reported in AC Watts
UPS Status:
AC Line, Standby, Test in progress, Test alarm
Charger Current:
Reported in Amps
Battery Discharge Current:
Reported in Amps
Battery State of Health
(Requires AlphaApps Option):
Power Supply internal analytic diagnostics report when batteries
should be serviced.
• Battery String Runtime Remaining
• Battery Life Remaining
Battery Voltage:
IDH4: Individual battery voltage, up to two strings of 3 or 4
batteries (maximum 8 batteries), ±100mV per battery, IDH4x:
Individual battery voltage, up to four strings of 3 or 4 batteries
(maximum 16 batteries), ±100mV per battery, IDH4L: Individual
battery voltage, up to four strings of 3 or 4 batteries (maximum
16 batteries), ±100mV per battery. Requires SAG option
Utility Status and Events
(Reuires AlphaApps Option):
AC Line Status:
• Utility Performance Status (outages, sags, surges, frequency)
• Utility Events (24-hour and lifetime number of events)
Battery Temperature:
Reported from power supply battery Remote Temperature
Sensor (RTS)
Remote Test Control:
Start/Stop power supply test cycle
History Log Reports:
• Power Supply Event Log (events of daily power supply operation)
• Power Supply Configuration Log (events that occur infrequently)
• Battery Event Log (battery conductance measurement and
battery manufacture dates
Enclosure Door:
Open or Closed
Generator Monitored Parameters (IDH4x Only)
Status:
Generator Off, Running, Alarm
Hardware
RF Cable Interface:
F-connector, female, 75 Ohm, connector angle accommodates
coax bend radius when installed in some enclosures
Generator Alarm:
Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel,
water intrusion, pad shear, gas hazard, test fail
Local Interface:
RJ-45, Ethernet,10/100Mbps
Gas Hazard:
OK, Alarm
Water Intrusion:
OK, Alarm
LED Indicators:
Ready/Alarm, Upstream registration, Downstream lock,
AlphaBus activity, RF level, Ethernet Link, CPE traffic, Battery
Sense harness correctly connected
Pad Shear:
OK, Alarm
Enclosure Door:
Open, Alarm
I/O Control (IDH4x and IDH4L Only):
6-pin Molex: Digital input, Digital output, 5V, Common
Ignition Battery Voltage:
±100mV
AlphaBus:
RJ-11 offset tab: Multi-power supply and
AlphaGen communications
Enclosure Temperature:
±2°C
Low Fuel:
OK, Alarm
Battery Monitoring:
IDH4: 8-pin Molex battery string A/B, IDH4x: 8-pin Molex battery
string A/B and 8-pin Molex battery string C/D, IDH4L: Requires
SAG Option
Remote Test Control:
Start / Stop generator test cycle
Tamper:
NO or NC, software configurable, reads enclosure door
magnetic switch
Transmit Frequency Range:
Cable Modem for DOCSIS 1.1 and 2.0
91 to 857Mhz
Output Power Range:
TDMA:
+8 to +54dBmV (32QAM, 64QAM)
+8 to +55dBmV (8QAM, 16QAM)
+8 to +58dBmV (QPSK)
S-CDMA:
+8 to +53dBmV (All modulations of S-CDMA)
Input Signal Range:
-15 to 15dBmV
Channel Bandwidth:
6Mhz
Environment
Operating Temperature:
-40 to 65°C / -40 to 149°F
Storage Temperature:
-40 to 85°C / -40 to 185°F
Humidity:
10 to 90% non-condensing
Regulatory Compliance:
FCC Part 15 Class A
EN 50083-2:2006 EMC requirements for CATV equipment
EN 62040-2:2006 Uninterruptible power supply EMC
requirements, Category C2
Surge: IEEE 587, Category B3
RoHS: Directive 2002/95/EC
Network Communications
DOCSIS (RF) Port Protocols:
IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP, SNTP
Ethernet Port:
Local Mode: HTTP web interface for local on-site diagnosis
CPE Mode: DOCSIS Cable modem Ethernet CPE functionality
MIBs:
Power supply (ANSI/SCTE 38-4)
Other SCTE HMS MIBs as defined by the SCTE for power
supply and generator status monitoring
Alpha proprietary advanced UPS diagnostics
5 to 42Mhz
Receive Center Frequency Range:
Additional Equipment
874-842-21 (P/N):
Wire Kit, Battery Sense, 1x36V, 6'
874-842-20 (P/N):
Wire Kit, Battery Sense, 2x36V, 6'
874-841-21 (P/N):
Wire Kit, Battery Sense, 1x48V, 6'
874-841-20 (P/N):
Wire Kit, Battery Sense, 2x48V, 6'
162-028-10 (P/N):
Surge Protector: Female/Female conector configuration,
"F" type connector with integralf ground block required for
all installations
29
Status Monitoring
Intelligent Power
Supply Interface:
Power supply user interface displays advanced diagnostics
including: DOCSIS modem upstream and downstream RF
levels, IP address assigned by network DHCP server, MAC
address and firmware levels, individual battery voltages to verify
correct wire harness installation
AlphaNet™ EDH4
External DOCSIS® Transponder
>Add DOCSIS Status Monitoring capability
to existing power supplies
AlphaNet EDH4
>Supports standard networking interfaces including
SNMP, Web access and ANSI/SCTE MIBs
>Multiple power supply models supported
>Embedded Web server for remote diagnostics
>Optional VoIP testing features
AlphaNet EDH4
Hardware
Specifications
Power Supplies Supported:
XM2-HP, XM2 (requires USM2 or USM2.5)
XM (requires APM/USM)
Lectro ZTT, ZTT+ AM (requires RPM card)
Dimensions
H x W x D (in/mm):
1.3 x 8.6 x 5.2 / 33 x 218 x 132
RF Cable Interface:
F-connector, female, 75Ohm impedance
DOCSIS Compatibility:
DOCSIS 1.1, 2.0
Local/Craft Interface:
RJ45 Ethernet
Monitoring Protocol:
SNMP v1, v2, v3
Devices Monitored:
Power supplies, batteries, generators1
Environment
Notes: 1 Reported as per ANSI/SCTE 25-3 2002 (HMS-022)
Status Monitoring
30
RF Transmit/Receive
Tx Frequency Range:
5 to 42MHz
Output Power:
8 to 58dBmV
Channel Bandwidth:
6MHz
Receive Center Freq Range:
91 to 857MHz (Standard, HRC, IRC channels)
Input Level:
-15 to 15dBmV
Operating Temperature:
-40 to 65°C / -40 to 149°F
Humidity:
10 to 90% non-condensing
Emissions:
EN55022 Class A and FCC Part 15 Class A
(Installed in power supply enclosure system)
Warranty:
2 years
Management
NMS/EMS:
Standard SNMP Management Tools
HMS MIBs:
In addition to the standard DOCSIS MIBs, the
transponder supports the following HMS MIBs:
• SCTE 25-3 (HMS-022): - Interface
• SCTE 36 (HMS-050): - Root
• MIB SCTE 37 (HMS-072): - Tree
• MIB SCTE 38-1 (HMS-026): - Property
• MIB SCTE 38-2 (HMS-023): - Alarm MIB
• SCTE 38-3 (HMS-024): - Common
• MIB SCTE 38-4 (HMS-027): - Power Supply
• MIB SCTE 38-6 (HMS-033): - Generator
• MIB SCTE 38-7 (HMS-050): - TIB MIB
Monitored Parameters
Power Supply Data
Model:
XM2-HP /
XM2
XM
AM
ZTT
Series
Major Alarm:
Minor Alarm:
Input Line Voltage:
1
1
1
Output Voltage:
1
Battery Voltage:
Output Current:
1
Standby/AC Line Fail:
-
Equipment/Test Fail:
Enclosure Door Status:
Remote Test Control:
Notes: 1 Requires optional cable assembly
Number of Battery Strings:
Up to four 36V or 48V strings
Battery Data:
Individual battery voltages
Battery compartment temperature
Continuity Software
DOCSIS® Power Supply Monitoring
>Enterprise-class, web-enabled
and standard-based
>Centralized transponder
provisioning and inventory
>Scheduled standby tests for
preventative maintenance
>Standby event dashboards
> Enterprise-class Software
> Scheduled Standby Tests Allow for
Web-enabled and standard-based Continuity-SPS (Standby
Preventative Maintenance
Power Supply) is a flexible, standby power supply status
Continuity-SPS allows you to proactively schedule standby
monitoring solution. Based on HMS and DOCSIS standards,
tests, which will alarm on risk areas on the network. A
Continuity-SPS supports any standards-based transponder,
dashboard graphically updates individual battery voltages
providing cable operators with an enterprise-class,
from standby tests every minute, making it easy to identify
centralized, feature-rich, web-enabled tool to monitor all the
questionable batteries. These batteries can be replaced
standby power supplies in the network.
during scheduled maintenance visits before they turn the
next standby event into an outage.
> Centralized Transponder Provisioning and Inventory
31
> Standby Event Dashboard
Continuity-SPS shows all current, standby events in an
provision all transponders from one central location.
easy-to-read dashboard. For each event, the standby event
Continuity-SPS also includes an up-to-date inventory of all
dashboard displays summaries of past standby events and
transponders that can be exported into Excel or CSV.
shows real-time battery voltages. The standby event
dashboard provides a powerful view into the network
during a power outage.
Status Monitoring
With Continuity-SPS you can automatically discover and
Enclosure Systems
A solid enclosure is an essential element of the power system for any outside plant installation.
With one of Alpha’s agency-certified enclosures, your power systems are protected from changes
in the climate, weather or theft.
>LPE Enclosure
The LPE is an ideal solution for cable network power when traditional equipment is too large or
bulky. Designed for multiple dwelling units and Fiber Deep applications, the LPE is more than 40
percent smaller than a standard PWE-3 enclosure. Engineered to work with the XM2-300HP
power supply, the LPE enclosure offers a low-profile solution to keep your customer’s
communication networks alive.
>NPS Enclosure
The NPS enclosure is optimal for use in business park, node segmentation and plant extension
applications. It is specifically designed for indoor and outdoor installations requiring lower power, a
smaller footprint and embedded DOCSIS® or proprietary status monitoring capability. The NPS
features equipment rack, wall, pole, floor or pedestal mounting options.
>Pole Mount Enclosures
Alpha’s Pole Mount enclosures are the most durable broadband power supply enclosures in the
industry. Each enclosure features a removable door and lid. Standard features include high magnetic
circuit breaker, duplex AC receptacle and service power inserter. Options include battery integration
tray, surge protector, battery heater mat, storm hood and battery expansion cabinets.
>Ground Mount Enclosures
>Extended Runtime Add-on Enclosures
Alpha’s battery expansion cabinet options include top and bottom mount cabinets for most
standard Alpha enclosures, as well as stand alone options to work with any broadband enclosure.
>Enclosure Accessories
Extend battery runtime and protect your power system investment. Security add-ons help prevent
theft of valuable equipment, while accessories like battery heater mat and battery spacers help get
the best performance from your batteries in any climate or condition.
>Powernode Systems
Alpha’s Powernode (PN) Series enclosures offer flexibility and modular expandability for broadband
power applications. Supporting centralized or distributed power architectures, PN Series enclosures
accommodate multiple power supplies, battery strings and natural gas or propane generators.
>Fibernode Power Enclosure
Designed for collocated power and fibernode configurations, the FPE enclosure provides a rugged
outdoor solution for multiple outside plant and fiber deep applications. With easy front, rear and top
access, and a universal node mounting bracket and wire management, the FPE provides a complete
system solution for expanding HFC networks.
>Surge Protection
Alpha’s surge protection devices provide reliable protection of power supplies and related
equipment from the damaging powerline disturbances common to cable broadband applications.
>Precast Pads for Enclosures
Alpha offers a full line of precast, polymer concrete pads for most Alpha enclosures systems.
>Pedestal Support Series
Alpha provides two pedestal support systems for the UPE Series ground mount enclosures.
33
Enclosure Systems
Alpha’s Ground Mount enclosures can be seen installed all over the world. Each enclosure features
a removable door and lid. Standard features include high magnetic circuit breaker, duplex AC
receptacle and service power inserter. Optional features include a battery integration tray, surge
protector, battery heater mat, storm hood, battery expansion cabinets and meter enclosure models.
MDU and Fiber Deep System
Pole, Wall or Ground Mount Options
>XM2-300HP 300 Watt Intelligent CableUPS® up
to 94% efficient with a small carbon footprint
>Smart DOCSIS transponder for
advanced status monitoring
>Advanced inverter and battery diagnostics
>Dual temperature probe for advanced
battery management
As we transition from traditional HFC to Fiber Deep topologies,
sometimes the right power is less power. Alpha’s new
XM2-300HP/LPE powering system incorporates DOCSIS®
communications to provide an efficient and economical
outside plant solution. The 300W output offers maximum
reliability to support low power applications in expanding
broadband networks.
Enclosure Systems
34
XM2-300HP CableUPS®
SPI-RF
High efficiency 300W power supply
Ideal for RFoG, MDU and N+1/N+0 applications
Small footprint and lightweight
Integrated DOCSIS® status monitoring
New predictive preventative maintenance
features
Programmable LCD Smart Display
Single network interconnect for power and
DOCSIS RF monitoring
RF attenuation control with SXP Pad
-110 dBC EMI shielded cast aluminum package
AC test points
“ALT/ON” switch for Service Power Supply
24 month warranty
DPM
Dual Temperature Probe
Ambient
Temperature
DOCSIS® based status monitoring card
Advanced battery monitoring capability
Detailed RF level indicators
LAP-SM Surge Protector
Pass through status monitoring
Critical protection from voltage transients
LA Series features piggyback plug to
optimize receptacle use
Battery
Temperature
A single cable monitors dual ambient
temperature for the battery negative
terminal and enclosure
Advanced battery management
AlphaCell™ 4.0HP Battery
Pure lead technology provides up to 20%
increased life expectancy
3 to 5 times longer shelf life vs. standard VRLA
Up to 5-year full warranty
Non-spillable UN2800 rating for ease
of transportation
Provides up to 50% increased runtime in
coldest climates
4.0HP offering 240 cable runtime minutes
LPE Enclosure
Indoor/Outdoor Enclosure
>Wall mount, pole mount and ground mounting options
>40% smaller than industry standard PWE-3 system
>Innovative thermal management airflow system
LPE Enclosure
LPE Enclosure
Mechanical
Innovative Convective Airflow System
Dimensions
H x W x D (in/mm):
26 x 16.5 x 12 / 661 x 420 x 305
Weight (lb/kg):
25 / 11.3
Material:
Exterior powdercoated aluminum
Battery:
220GXL or two 70HPL-FTs
Door and Lid Seal:
Poron gasketing
Color:
Gray (custom colors available)
Lid:
Removable
Door:
Hinged, removable
Slanted lid
draws heat
up and out
“Chimney effect”
provides active
convection cooling
35
Options
Pole mount bracket, wall mount bracket,
ground mount bracket
Battery Heater Mat:
Used in cold-climate applications
Battery Retaining Bar (BRB):
Secures batteries within enclosure
Coax Connection:
SPI or SPI-RF
Door Locks:
Optional GEM lock
Lightning Arrester:
LA-P+ 120V, LA-P-120T,
Surge Arrester Kit
Service Entrance:
70A available
Status Indicators:
Local/Remote Indicator (LRI)
Coax Surge Protection:
75 Ω Coax, MF
75 Ω Coax, FF w/Gnd
75 Ω Coax, FF
Hotter
Extreme weather
resistant louver
free design
Cool air intake
through bottom
of enclosure
Cooler
Other Cost Effective Indoor Wall Mount Options
Smallest Available Footprint
Volume = 10.8ft3
Volume = 7.2ft3
Volume = 2.8ft3
Wall Mount Shelf with
SPI mount bracket
UPE-6 – ground mount ­
PWE-6 – pole mount ­
LPE – pole mount /
wall mount shown­
Wall Mount Rack (WMR)
Enclosure Systems
Mounting Hardware:
Node Power System
Rack, Pole, Wall or Floor Mount Options
>For low power applications including
Fiber Deep up to Node + 6 actives
>Optional AlphaGuard™ battery balancer
and SPI-RF service power inserter
>Multiple battery configurations
for extended runtime
The Node Power Supply (NPS) enclosure is an integrated
CableUPS® system for use in Multi Dwelling Units (MDU),
business parks, node segmentation and plant extension
applications. The NPS is specifically designed for indoor or
outdoor installations requiring lower power, a smaller footprint
and embedded DOCSIS® or proprietary status monitoring
capability. The NPS can be conveniently mounted in an
equipment rack, a wall, pole, or to a floor pedestal using the
36
appropriate installation kit. The NPS is an ideal solution for
back-up power where traditional equipment is too large
Enclosure Systems
and bulky.
CableUPS®
Enclosure fits XM2-906HP and XM2-300HP
Industry leading highest efficiency for lower
operating costs
Featuring i2M™ Intelligent Inverter Module for
XM2-HP and XM2 Platforms
Displays Critical Smart DOCSIS® parameters
and individual battery voltages
Sharper easy-to-read blue LCD Smart Display
SPI-RF
Single network interconnect carrying system
power and DOCSIS® RF monitoring signals
RF level control with SXP PAD
FRT shielded cast aluminum package
Enclosure Cooling Fan (ECF) Systems
Enclosure Cooling Fan enhances air circulation
in an enclosure's battery compartment
Air flow eliminates “hotspot” premature battery
failures in hotter climates
Significantly reduces the power supply
compartment temperature
AlphaGuard™
Extends battery life
Spreads charge voltage equally across batteries
Compensates for battery differences as they age
Identify and replace single suspect batteries,
not the entire string
Single battery connections for charge
management and status monitoring
Batteries
Deliver 100% “out-of-box” capacity — no
cycling required
Premium Gel model offers 50% longer life than
traditional gel batteries
Silver Alloy minimizes grid corrosion
Maintenance-free threaded inserts; no
periodic retorquing
Front terminal design with protective covers
High cyclic life capability
Flame retardant case and cover (to UL94VO)
3-step terminal seal design ensures
leak-free operation
Integral handles (115HPL-FT, 220HPL-FT)
for ease of handling
NPS Enclosure
Indoor/Outdoor Enclosure
>Engineered for broadband powering applications
>22% smaller than industry standard PWE-3 system
>Convenient pole, wall, ground and rack mount options
>Aluminum-welded construction and
durable powdercoated exterior
>Multiple enclosure accessories and options available
NPS Enclosure (Rack mount option)
NPS Enclosure (For use with XM2-906HP and XM2-300HP)
Models:
NPS-R
NPS-W1
NPS-W2
NPS-F
NPS-P
Installation:
Indoor
Indoor
Outdoor
Indoor
Outdoor
Description:
19" and 23" rack mount
Wall mount
Wall mount
Floor mount
Pole mount
Dimensions
H x W x D (in/mm):
22.75 x 19 x 14.14 /
578 x 432 x 359
22.75 x 17 x 14.14 /
578 x 432 x 359
22.75 x 17 x 14.14 /
578 x 432 x 359
22.75 x 17 x 14.14 /
578 x 432 x 359
22.75 x 17 x 14.14 /
578 x 432 x 359
Weight (lb/kg):
39 / 17.7
39 / 17.7
39 / 17.7
39 / 17.7
39 / 17.7
Configurations
Mechanical
37
Node Power
Supply Enclosure
Configurations:
Shown with 115 HPL Batteries
Specifications
Material:
Exterior powdercoated aluminum
Door:
Hinged removable
Door and Lid Seal:
Poron gasketing
Tamper Switch:
Optional
Color:
Gray (custom colors available)
Battery Side Tray:
Optional
Lid:
Removable
Smallest Available Footprint
Volume = 3.54ft3
Volume = 4.8ft3
PWE-3 – pole mount ­
NPS – rack mount
Enclosure Systems
Shown with GXL Batteries
PWE Enclosure
Outdoor Pole Mount Enclosures
>Engineered for broadband powering applications
>Aluminum welded construction and durable powdercoated exterior
>Agency certified to meet applicable industry standards
>Internal or external SUSE rated service entrance options
>Optional Battery Integration Tray (BIT)
PWE-3
>Portable generator cabling access door
>Optional Northern Enclosure available for colder climates
PWE Enclosures
PWE-3
PWE-3
Northern Enclosure
PWE-4
PWE-6
PWE-6
Northern Enclosure
Dimensions
H x W x D (in/mm):
24.5 x 24.3 x 14 /
622 x 615 x 355
25.4 x 24.8 x 14.1 /
645 x 628 x 359
24.8 x 30.3 x 16 /
629 x 768 x 406
36.8 x 24.3 x 14 /
933 x 615 x 355
37.7 x 24.8 x 14.1 /
958 x 628 x 359
Weight (lb/kg):
39 / 18
(without batteries)
42 / 19.1
(without batteries)
57 / 26
(without batteries)
68 / 31
(without batteries)
73 / 33.1
(without batteries)
PWE-6FT
PWE-8
PWE-9
PWE-D36
Dimensions
H x W x D (in/mm):
27.5 x 29.3 x 17.5 /
698 x 753 x 445
36.9 x 30.3 x 16 /
937 x 768 x 406
47 x 24.3 x 14 /
1194 x 615 x 355
47 x 24.3 x 14 /
1194 x 615 x 355
Weight (lb/kg):
57 / 26
(without batteries)
121 / 55
(without batteries)
85 / 38.5
(without batteries)
75 / 34
(without batteries)
Models:
Mechanical
Enclosure Systems
38
PWE Enclosure
Configurations
PWE Enclosures (cont.)
Models:
Mechanical
PWE Enclosure
Configurations
Specifications
Northern Enclosure Hood and Door for Colder Climates
Material:
Exterior powdercoated aluminum
Door and Lid Seal:
Poron gasketing
Color:
Gray (custom colors available)
Lid:
Removable
Door:
Hinged removable
Pole Mount:
Galvanized steel brackets for wood and concrete
pole mount and wall mount
Tamper Switch:
Optional
Battery Side Tray:
Optional
Northern Enclosures feature Z-bracket, vented hood and doors with
no batting required.
UPE and UPE-M Enclosures
Outdoor Ground Mount Enclosures
>Engineered to accommodate broadband powering applications
>Internal or external SUSE rated service entrance options available
>Enclosures are CSA/UL certified to meet applicable industry standards
>Aluminum-welded construction and durable powdercoated exterior
>Portable generator cabling access door
>Multiple enclosure accessories and options available
UPE-6
UPE - Ground Mount Enclosures
Models:
UPE-3
UPE-4
UPE-6
UPE-6L
UPE-8
Dimensions
H x W x D (in/mm):
33.5 x 26 x 15 /
851 x 660 x 381
35 x 34.5 x 15 /
889 x 876 x 381
48 x 26 x 15 /
1219 x 660 x 381
36 x 26 x 15 /
914 x 882 x 381
45.5 x 34.5 x 15 /
1136 x 882 x 381
Weight (lb/kg):
61 / 28
(without batteries)
72 / 32
(without batteries)
75 / 34
(without batteries)
68 / 30
(without batteries)
121 / 55
(without batteries)
Mechanical
39
UPE Configurations:
Models:
UPE-M3
UPE-M6
UPE-M8
Dimensions H x W x D (in/mm):
45 x 26 x 19.7 / 1143 x 660 x 482
57.3 x 26 x 19.7 / 1455 x 660 x 482
50 x 32 x 20.5 / 1270 x 813 x 521
Weight (lb/kg):
100 / 44 (without batteries)
130 / 59 (without batteries)
140 / 64 (without batteries)
Mechanical
UPE-M Configurations:
Specifications
Material:
Exterior powdercoated aluminum
Door and Lid Seal:
Poron gasketing
Color:
Gray (custom colors available)
Lid:
Removable
Door:
Removable/lockable
Ground Mount:
Precast polymer concrete pad (optional)
Tamper Switch:
Optional
Battery Side Tray:
Optional
Enclosure Systems
UPE - Metered Ground Mount Enclosures
Extended Runtime Enclosures
>Upgrade existing Alpha enclosures
>Extend existing runtimes by up to 300%
>Plant hardening option for voice and
data broadband networks
>Generator options available
BE-PWE mounted on PWE-3
BE-PWE
Adds battery capacity to the PWE-3 Enclosure
Installs onto top of PWE-3
Kit Includes enclosure with sliding battery tray,
door, battery cabling and pole mount bracket
Compatible with AlphaCell® 165, 195 and
220 Batteries
UBE-PWE
Enclosure Options
40
Adds battery capacity to the PWE-3 Enclosure
Installs onto bottom of PWE-3
Kit Includes enclosure with sliding battery tray,
door, battery cabling and pole mount bracket
Compatible with AlphaCell 165, 195 and
220 Batteries
BE-UPE
LBE-3
Adds battery capacity to Lectro 3 battery pole
mount enclosure
Installs onto bottom of Lectro Enclosure
Kit Includes enclosure with sliding battery tray,
door, battery cabling and pole mount bracket
Compatible with AlphaCell 165, 195 and
220 Batteries
Underground Battery Vaults
Thermally stable underground environment helps
promote maximum battery life and performance
Reduces visual impact with below-grade
battery installation
Durable, maintenance-free, long-lasting, utility
approved and non-combustible material
Large battery capacity houses up to eight
batteries for extended backup time
Flexible enclosure options for both pole and
ground mount systems
PWE Generator Expansion Module
Adds battery capacity to the UPE-3 Enclosure
Kit Includes enclosure and battery cabling
Compatible with AlphaCell 165, 195 and
220 Batteries
PWE-SG
Adds battery capacity to any OEM pole
mount enclosure
Installs underneath of existing pole
mount enclosure
Kit includes conduit kit, battery cabling and
pole mount bracket
Accommodates 3 or 4 AlphaCell 165, 195
or 220 Batteries
Provides an easy means to pole mount the
AlphaGen™ EU2000
Protects generator from inclement weather
Prevents theft of valuable portable generators
Field installable using two rails attached to the
bottom of the PWE
Backwards compatible with existing enclosure
Accommodates Line Transfer Switch (LTS)
Can be easily removed after extended outage
or left in place
Designed to provide four to ten hours of
additional runtime
Universal Generator Expansion Module
Add an AlphaGen EU2000 to an Alpha PWE
or UPE Enclosure
Protects generator from inclement weather
Prevents theft of valuable portable generators
Backwards compatible with existing enclosure
Can be easily removed after extended outage
or left in place
Designed to provide four to ten hours of
additional runtime
Enclosure Accessories
>Retrofit existing enclosures
>Easy installation and maintenance
>Cooling options extend battery and power supply life
>Heating options for maximum protection
Enclosure Cooling Fan (ECF) Systems
PWE/UPE series
The Enclosure Cooling Fan enhances air
circulation in an enclosure's battery compartment
Air flow eliminates “hotspot” premature battery
failures in hotter climates
Significantly reduces the power supply
compartment temperature
Calculated Mean Time Between Failure (MTBF)
studies indicate this will extend power supply
life by two years
PowerNode series
Battery Spacer Clip (BSC)
Battery Retaining Bar
Provides added security against the
batteries from falling out or being thrown
from an enclosure
Easily snaps into place
Prevents power supply from sliding off the shelf
or being thrown from an PWE enclosure
Bolted to enclosure and clips to handle of supply
Constructed of braided steel cable and
carabiner style clips
Battery Integration Tray (BIT)
Factory installed option in any new PWE-3/6
and UPE-3/6 enclosures
Eliminates battery cable kits and slide trays
Greatly reduces battery preventative maintenance
Pre-wired voltage sense leads for transponder
and AlphaGuard
Allows for the direct connection of generator
41
Battery Heater Mat
Consumes 30% less power than
previous designs
Durable polyester construction and
insulated design
Sealed on-mat electronics for
maximum protection
On-mat thermal switch and thermal fuse
for redundant safety
Piggyback plug standard on 120V models
Ladder Bracket
Provides safe access for servicing power
supplies and batteries without a bucket truck
Attaches to PWE enclosures; does not require
a pole attachment point
Heavy-duty galvanized steel construction
Includes a safety belt attachment location
accepting strand hook ladders less
than 20" in width
Enclosure Options
Designed for use with most group
27 or 31 VRLA batteries
Easy installation - clips to the top of the battery
Increases battery life expectancy by
providing critical battery spacing
required for proper ventilation
Accurately positions and secures the
Remote Temperature Sensor (RTS)
Strongly recommended for hot climates
Designed to last over 30 years or lifetime
of the equipment
Module Retaining Cable
Security Enclosure Accessories
>External security options available to prevent
unauthorized entry and serve as theft deterrent
>Internal security solutions to protect
costly power system components
>Multiple security options available to
maximize power system investment
PWE High Security Device
High visibility theft deterrent
Stainless steel construction - corrosion resistant
Locking system prevents access to padlock
shackle (to prevent cutting of lock)
Ground Mount Security Bar For UPE / UPE-M / PN Enclosures
42
High visibility theft deterrent
Powdercoated-corrosion resistant
Locking system prevents access to padlock
shackle (to prevent cutting of lock)
Enclosure Options
AlphaCell® Anti-Theft Label
Destructible vinyl - made to fracture if tampered
with. Will not easily peel off
Temperature and chemical resistant
Large, identifiable size (4x6)
Customizable with logo
PWE High Security Device
Battery Security Device
This custom-fitted framework secures the
batteries in the equipment enclosure. A hinged,
double-wall reinforced cross beam with enclosed
padlock housing locks the batteries in place,
while still allowing access by service personnel
for maintenance. Heavy-duty design and powdercoated steel construction provide the appropriate
level of security to system batteries.
Security Bar Kit
Alpha’s Enclosure Security Bar prevents
unauthorized access to pole-mount power
system enclosures. It also helps secure enclosure
contents during unforeseen emergency or
natural disaster situations. Heavy-duty reinforced
steel construction and swing-away hinged
design strike the right balance between
protection and serviceability. An enclosed
padlock housing further protects the enclosure
from unauthorized access.
DeWalt MobileLock
Nationwide GPS Locator with Anti-Theft controls
Customizable alarm sensors
(vibration, tamper, temperature)
Long life battery (up to 1 month)
Mobile alert via email or cell phone
Tamper Switch
This magnetic door switch provides an intrusion
alarm through remote status monitoring and
may be ordered with normally-closed or normallyopen contacts.
Power Supply Hold-Down Bracket
This security device consists of a metal
framework wrap that secures the power supply
in place, guarding against theft, vandalism and
movement during natural disasters or other
extreme conditions such as traffic accidents.
Safety Padlock
This hardened steel, corrosion-resistant, thinprofile padlock is a critical element in preventing
unauthorized access while still allowing keyed
entry to secured areas. Additionally, restricted
keyways, customer-specific key codes and
exclusive key blanks allow operators to
establish a comprehensive keying strategy. It
is an excellent addition to other Alpha Security
Accessories as its size and thin-profile design fit
within the enclosed padlock housings.
HSHP Enclosure
High Security High Performance Enclosure
>All-in-one maximum security enclosure
>Internal and external security provisions
to prevent against unauthorized entry
>Flush surface design and concealed
hinges limit pry points
>Added security options for exclusive
senior management dual-key access
Internal Battery Security Bar
HSHP Enclosure
Weldable Tabs
Internal Security Bar locks the batteries inside the
enclosure. Exclusive Alpha security screws are
required to attached the bar to the shelf and the
bottom hooks into the internal base plate.
Concealed Hinges
Optional tabs can be added to the top and
bottom of the door which can be welded closed.
A grinder is required to remove the tabs.
Enclosure features concealed hinges prohibiting
any external access. The internal hinges are
equipped with a release pin to remove the door
when servicing.
43
High Security Latch Key Locks
The enclosure's constructed with a recessed
door to limit prying points. Attempts to pry will
cause the until to lock up the door frame.
Equipped with internal lock latches that hook
directly into the enclosure to protect from access
to prying.
Custom Keyed Security Bolt
An Alpha exclusive security screw is provided
to lock the power supply directly to the cabinet
itself. This feature adds senior management
dual-key access.
Optional Mul-T-Locks
Optional 3-in-1 changeable combination cylinder
for maximum protection
Reinforced Door Design
The enclosure door is reinforced with an internal
U-Channel frame around the entire perimeter
of the door. When door is closed, the internal
U-Channel is locked between the enclosure and
the door.
Enhanced Lid:
The lid is security bolted to the enclosure and
nested to the enclosure to enhance overall
strength of the enclosure and limit pry points.
Enclosure Options
Recessed Door Design
Powernode Systems
Extended Runtime Powering
>Supports centralized or distributed powering architectures
>Compatible with AlphaGen™ generator systems or
multiple battery strings for extended runtime solutions
PN-3 with AlphaGen
CESC
Specifications
Enclosure Systems
44
CESC
Dimensions
H x W x D (in/mm):
44 x 15 x 24 /
1118 x 381 x 610
Weight (lb/kg):
51 / 23.13
Power Supply Capacity:
One power supply
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
Sidecar
1 Power Supply,
1 Battery String
PN-3
Specifications
Dimensions
H x W x D (in/mm):
44 x 26 x 24 /
1118 x 660 x 610
Weight (lb/kg):
115 / 52 (without trays)
Power Supply Capacity:
Up to two power supplies
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
Single PN-3
Dual PN-3
PN-3/CE-3X2
1 Power Supply
2 Battery Strings
2 Power Supplies
4 Battery Strings
2 Power Supplies
1 Battery String
AlphaGen™ Generator
The PN-3 enclosure can accommodate a maximum combination of three equipment or battery trays.
PN-3-HS (High Security)
Specifications
Dimensions
H x W x D (in/mm):
44 x 26 x 24 /
1118 x 660 x 610
Weight (lb/kg):
115 / 52 (without trays)
Power Supply Capacity:
Up to two power supplies
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
PN-3-HS
PN-3/SC-HS
PN-3/SC-HS
Battery Cabinet
3 Battery Strings
Sidecar and Battery Cabinet
1 Power Supply
4 Battery Strings
High Security Locks
The PN-3/SC-HS system has recessed star bolt security locks to prevent unauthorized entry. Reinforced door
frames. Doors reinforced with welded channel for strength.
Powernode Systems
Extended Runtime Powering
>SUSE and EUSERC rated options available
>CSA/UL certified to meet applicable industry standards
>High security options
PN-4 with AlphaGen
CESC-3x2
Specifications
CESC-3x2
Dimensions
H x W x D (in/mm):
44 x 41 x 24 /
1118 x 1041 x 610
Weight (lb/kg):
428 / 194.1 (without trays)
Power Supply Capacity:
One power supply
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
1 Power Supply
1 Battery String
AlphaGen™ Generator
45
The most compact, cost effective “allin-one” power system. The CESC-3x
provides for a single power module,
batteries, and generator in a low
profile, minimum footprint design.
Specifications
Dimensions
H x W x D (in/mm):
52 x 26 x 24 /
1320 x 660 x 610
Weight (lb/kg):
145 / 66 (without trays)
Power Supply Capacity:
Up to three power supplies
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
Single PN-4
Dual PN-4
PN-4/CE-9X2
2 Power Supplies
2 Battery Strings
3 Power Supplies
4 Battery Strings
2 Power Supplies
2 Battery Strings
AlphaGen Generator
The PN-4 enclosure can accommodate a maximum combination of four trays. A maximum of either three power
modules or three battery trays can be installed.
PN-6
Specifications
Dimensions
H x W x D (in/mm):
39 x 52 x 24 /
990 x 1321 x 610
Weight (lb/kg):
250 / 113 (without trays)
Power Supply Capacity:
Up to three power supplies
Color:
Seafoam Green,
optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
PN-6
PN-6
PN-6 and PN-6X
3 Power Modules
2 48V Battery strings
Optional Battery Drawer
3 Power Modules
4 48V Battery strings
3 Power Modules
2 48V Battery strings
Optional Battery Drawer
AlphaGen Generator
The PN-6 offers a low profile design that accommodates up to three power modules. An optional Battery Drawer
(BD-8) fits under the PN-6 to provide easy access storage for up to eight batteries.
Note: PN-6 with PN-6x dimensions are (in/mm) 57H x 91W x 24D / 1448H x 2311W x 610D with BD-8 and generator
pedestal. PN-6 with PN-6x dimensions are (in/mm) 39H x 91W x 24D / 991H x 2311W x 610D without BD-8
and generator pedestal
Enclosure Systems
PN-4
Fibernode Power Enclosure
>Designed for collocated power and fiber node configurations
>Thermally optimized for todays fiber nodes
>Flexible configurations to accommodate
multiple fiber deep applications
Fibernode Power Enclosure (Front)
Architecture — N+1 (Approximately 6 Actives)
XM2-906HP, 3 or 6 AlphaCell® Batteries and a DCX3000 Portable Generator
XM2-906HP Runtime (Hrs)
3 Batt
Load
195 GXL
6 Batt
4.0HP
195 GXL
DCX-3000
4.0HP
Max.
Runtime**
2
14.1
17.3
29.9
37.4
20.0
57.4
3
10.1
12.4
21.6
26.7
19.9
46.6
4
7.7
9.5
16.6
20.5
19.8
40.3
4.6*
6.7
8.3
14.5
17.9
19.8
37.7
5
6.2
7.7
13.4
16.5
19.7
36.2
* 4.6A = 417W @ 90V ** Max. Runtime with 4.0HP and DCX-3000
Node Plus 1 Architecture*
46
.55 A
1.3 A
.55 A
.55 A
.55 A
Enclosure Systems
.55 A
Example = 417 Watts @ 90 VAC
.55 A
1
x 1.3 AMP = 120 Watts @ 90 VAC
6
x .55 AMP = 3.3 AMP = 297 Watts @ 90 VAC
Architecture — N+2 (Approximately 20 Actives)
XM2-918HP, 3 or 6 AlphaCell Batteries and a DCX3000 Portable Generator
XM2-918HP Runtime (Hrs)
3 Batt
6 Batt
DCX-3000
Max.
Runtime**
13.4
19.5
32.9
10.1
18.5
28.6
6.4
8.0
17.0
25.0
3.1
5.2
6.6
15.0
21.6
2.2
3.1
5.1
6.4
14.8
21.1
14
1.9
2.7
4.3
5.5
13.5
19.0
16
1.6
2.3
3.7
4.7
12.0
16.7
Load
195 GXL
4.0HP
195 GXL
4.0HP
6
5.0
6.3
10.9
8
3.7
4.8
8.2
10
2.9
3.8
12
2.3
12.3*
* 12.3A = 1110W @ 90V ** Max. Runtime with 4.0HP and DCX-3000
Node Plus 2 Architecture*
.55 A
.55 A
.55 A
.55 A
.55 A
1.3 A
.55 A
.55 A
.55 A
.55 A
.55 A
.55 A
.55 A
.55 A
.55 A
Example = 1110 Watts @ 90 VAC
.55 A
.55 A
1
x 1.3 AMP = 120 Watts @ 90 VAC
20
x .55 AMP = 11 AMP = 990 Watts @ 90 VAC
.55 A
.55 A
Fibernode Power Enclosure
>Universal node mounting bracket provides easy installations
>36" width allows for horizontal node mounting
>High security option available
>Easy front and rear access
Fibernode Power Enclosure (Rear)
Architecture — N+0
XM2-300HP, 1 AlphaCell Battery and 2-Battery Back-up Pack
XM2-300HP Runtime (Hrs)
1 Batt
Back-up Pack**
4.0HP
4.0HP
0.5
28.0
60.1
88.1
1.0
14.0
30.1
44.1
Load
Max. Runtime w/
4.0HP and B/U Pack
1.3*
10.5
22.7
33.3
1.5
9.1
19.6
28.7
20.8
2.0
6.6
14.1
2.5
5.1
10.9
16.0
3.0
4.2
8.8
13.0
* 120W Node or 1.3A @ 90V
** Additional runtime back-up pack of 2 AlphaCell 4.0HP batteries
47
Fibernode Power Enclosure
Specifications
45 x 36 x 32 / 1143 x 914.4 x 812.8
Weight (lb/kg):
145 / 66 (without trays)
Power Supply Capacity:
Up to two power supplies
Color:
Seafoam Green, optional colors available
Standard Features:
Removable/lockable doors
Finish:
Durable powdercoat exterior
Material:
Aluminum
Architecture — 8N+2 (8 Nodes with 1-2 Actives Each)
XM2-924HP, 4 or 8 AlphaCell Batteries and a DCX3000 Portable Generator
XM2-924HP Runtime (Hrs)
Load
4 Batt
8 Batt
4.0HP
4.0HP
Max. Runtime w/
4.0HP and DCX
DCX-3000
14
3.6
7.6
13.5
21.1
16
3.1
6.6
12.0
18.6
17*
3.0
6.2
11.5
17.7
18
2.8
5.8
11.0
16.8
20
2.5
5.1
9.5
14.7
22
2.2
4.6
9.0
13.6
* 17A = 1530W @ 90V
8 Nodes Plus 1 Architecture
.55 A
1.3 A
1.3 A
.55 A
.55 A
.55 A
8 Fiber Nodes
with 1-2 Actives
Fed by One
XM2-924HP
1.3 A
.55 A
1.3 A
1.3 A
.55 A
Example = 1530 Watts @ 90 VAC = 17A @ 90 VAC
1.3 A
.55 A
.55 A
8 x 1.3 AMP = 10.4 AMP = 940 Watts @ 90 VAC
.55 A
12 x .55 AMP = 6.6 AMP = 594 Watts @ 90 VAC
.55 A
.55 A
.55 A
1.3 A
1.3 A
Enclosure Systems
Dimensions
H x W x D (in/mm):
Surge Protection
>UL 1449 3rd Edition Approved
>Critical protection from voltage transients
LA-P+
LA-P-120T
ISA-120/240
>Plug-in or hardwired solution utilizing
Metal Oxide Varistor (MOV) protection
>VSS 120/VSS 240 Series provides
downed power line protection
VSS 120/VSS 240
Surge Protection
Operating Voltage:
120V Models
Model Selection
Good
Better
Best
Series Model:
LA-P+ 120
LA-P-120T
VSS 120-15
/ NO
Outlet Type / Pass Thru:
Enclosure Options
48
/ YES
240V Model
2
120/240V Models
Best
Best
Good
Best
VSS-120-202
ISA 120/2401
LA-P+240
VSS2402
/ YES
/ Yes
Hardwired / NA
/ NO
/ YES
Protection:
L / N /G
L/N/G
L/N/G
L/N/G
L/N/G
L1 / L2 / G
L1 / L2 / G
Operating Temperature:
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
-40 to 55°C /
-40 to 131˚F
LED Indicator:
Yes
Yes
Yes
Yes
Yes
Yes
Yes
UL 1449 3rd Edition Specifications
Voltage Let Through
Protection Rating:
700Vp
500Vp
500Vp
500Vp
700Vp / 1200Vp
1200Vp
500Vp
Nominal Discharge
Current Rating
3kA
3kA
20kA
20kA
10kA
3kA
20kA
Maximum Continuous
Operating Voltage (MCOV):
150Vac
130Vac
275Vac
275Vac
150Vac / 300Vac
320Vac
275Vac
Notes:
1
The ISA surge protection devices are factory wired on the load side of the service entrance and available for field replacement. These arrestors should be installed by a licensed electrician.
2
UL1449 3rd edition not required
COAX Protectors
COAX Protector Specifications
Ideally suited to protect costly status-monitoring transponders, digital set top
boxes, cable modems and satellite receivers in the headend as well as high-end
HDTV sets from potentially damaging surges. The patented coaxial gas tube surge
protector is equipped with an integral fail-safe mechanism. Listed to UL 497, CSA
Listed Certified and complies with 1999 national Electric Code.
Part Number:
• Patented In-Line® Coaxial gas tube surge protection
• Provide lightning and surge protection for distribution, customer premises
and headend equipment
• Improves broadband network reliability and reduces service outages
• Power passing
• Listed to UL 497, CSA Listed Certified & complies with NEC
Part Number
Description
162-029-10:
Female/Female connector configuration, “F” type connector
162-027-10:
Male/Female connector configuration, “F” type connector
162-028-10:
Female/Female connector configuration, “F” type
connector with integral ground block
162-029-10/162-027-10
162-028-10
RF Performance
Frequency Range:
DC – 1.0 GHz
1.0 GHz to 1.5 GHz
Characteristic Impedance:
75 Ohms
75 Ohms
Insertion Loss (includes flatness):
<0.3dB / 0.2dB typical
<0.3dB
Return Loss:
>30dB
> 20dB
Protection
DC Breakdown @ 2000V/s:
150V to 300V
Impulse Breakdown @ 100V/µs:
< 450V
Insulation Resistance:
> 100 MegOhms
Surge Life*
10A, 10/1000µs:
>1500 Surges
100A, 10/1000µs:
>100 Surges
1000A, 10/1000µs:
>10 Surges
5000A, 8/20µs:
>10 Surges
AC Life
5A, 1000Vac, 1s:
>5 Operations
1A, 1000Vac, 1s:
>60 Operations
Failshort
COAX Protectors
30A, 1000Vac:
>15min
Operating Temperature:
-40 to 65°C / -40 to 149°F
*
All specifications for service life only
Precast Pads
For Alpha Enclosures
>Polymer concrete pads are reinforced
with mineral aggregates
>Precast concrete pads are made from highstrength fiber-cement and lightweight concrete
>Includes 3/8" mounting hardware
Polymer Concrete (PCC)
Models:
Enclosure
PCC-3:
PN-3 or PN-4
PCC-3-3X:
PN-3 + PN-3 or
PN-4 + PN-4
PN-3 + CE-3X2 or
PN-4 + CE-9X2
PCC-3X:
CE-3X2 or CE-9X2
PCC-3X-3G:
CE3X2 + CE3G or
CE-9X2 + CE3G
PCC-3-3:
Precast Concrete (PCD)
7.5K
PCC-A-PN6:
PN-6 (Part 1 of 2)
PCC-B-PN6X:
7.5K (Part 2 of 2)
PCC-PN6:
PN-6
PCC-RMB:
RMB
PCC-SC:
CESC
PCC-SC-3X:
CESC + CE-3X2 or
CESC + CE-9X2
PCC-SCFN:
SCFN
PCC-SC-RMB:
SC + RMB
PCC-UPE:
PCC-UPEM:
UPE-3, UPE-4,
UPE-6 or UPE-8
UPE-M3, UPE-M6
or UPE-M8
Weight
(lb/kg)
Models:
Enclosure
36 x 38 x 3 /
914 x 965 x 76
36 x 65 x 3 /
914 x 1651 x 76
36 x 65 x 3 /
914 x 1651 x 76
36 x 38 x 3 /
914 x 965 x 76
36 x 64 x 3 /
914 x 1626 x 76
51 x 36 x 3 /
1295 x 914 x 76
29 x 58 x 3 /
736 x 1473 x 76
29 x 42 x 3 /
736 x 1066 x 76
36 x 64 x 3 /
914 x 1626 x 76
44 x 42 x 3 /
1117 x 1066 x 76
27 x 36 x 3 /
685 x 914 x 76
36 x 54 x 3 /
914 x 1372 x 76
27 x 36 x 3 /
685 x 914 x 76
44 x 54 x 3 /
1117 x 1371 x 76
28 x 45 x 3 /
711 x 1143 x 76
40 x 40 x 3 /
1016 x 1016 x 76
120 / 54.4
PCD-3:
PN-3 or PN-4
195 / 88.4
PCD-3-3:
200 / 90.7
PCD-3-3X:
120 / 54.4
PCD-3-3X-3G:
PN-3 + PN-3 or
PN-4 + PN-4
PN-3 + CE-3X2 or
PN-4 + CE-9X2
PN-3 + CE-3X2 + CE-G or
PN-4 + CE-9X2 + CE-G
190 / 86.1
PCD-3X:
CE-3X2 or CE-9X2
190 / 86.1
PCD-3X-3G:
CE-3X2 + CE-3G or
CE-9X2 + CE-9G
232 / 106.5
PCD-A-PN6:
PN-6 (Part 1 of 2)
125 / 56.6
PCD-B-PN6X:
7.5K (Part 2 of 2)
180 / 78.5
PCD-D36:
PWE-D36 or PWE-9
180 / 81.6
PCD-SC:
CESC
85 / 38.5
PCD-SC-3X:
CESC + CE-3X2 or
CESC + CE-9X2
170 / 77.1
PCD-SC-3X-3G:
CESC + CE-3X2 + CE-G
85 / 38.5
PCD-UPE3:
UPE-3 or UPE-6
230 / 104.3
PCD-UPE4:
UPE-4 or UPE-8
Dimensions
H x W x D (in/mm)
Weight
(lb/kg)
36 x 38 x 3 /
914 x 965 x 76
36 x 64 x 3 /
914 x 1625 x 76
36 x 65 x 3 /
914 x 1625 x 76
36 x 90 x 3 /
914 x 2286 x 76
36 x 38 x 3 /
914 x 965 x 76
36 x 65 x 3 /
914 x 1625 x 76
29 x 58 x 3 /
736 x 1473 x 76
29 x 42 x 3 /
736 x 1066 x 76
27 x 44 x 3 /
685 x 1117 x 76
27 x 38 x 3 /
685 x 914 x 76
36 x 53 x 3 /
914 x 1346 x 76
36 x 79 x 3 /
914 x 2006 x 76
27 x 44 x 3 /
685 x 1117 x 76
27 x 44 x 3 /
685 x 1117 x 76
154 / 69.9
264 / 11.8
264 / 119.8
366 / 166
154 / 69.9
260 / 117.9
196 / 88.9
142 / 64.4
134 / 60.8
114 / 51.7
220 / 99.8
325 / 147.4
134 / 60.8
134 / 60.8
190 / 86.1
144 / 65
Pedestal Support Series
Pedestal Support for UPE Enclosures
>Three pedestal support systems for all UPE series applications
>Universal cover is easily field-configured
>Vaults for greater stability and cable slack storage
>Provides space for sweeps to enter the enclosure
Structural Foam Precast Enclosure Pedestals
Models:
PS-1:
PS-2-ECR:
PS-6:
PS-6XL:
UPE-3
UPE-4
UPE-6 UPE-6L
UPE-8
-
-
-
-
UPE-M3
UPE-M6
UPE-M8
-
-
-
Note: Meter load center and ECR through hole in PS6 cover is easily drilled through as required.
Features
Polyethylene Construction:
Large Body Design:
Flush Mount Enclosure Surface:
Mounting Hardware:
Eliminates the need for costly and time consuming concrete work
Provides convenient working space for connections
No enclosure distortion due to uneven concrete installations
Included
49
Enclosure Options
PCC-7K5:
Dimensions
H x W x D (in/mm)
Generators
Adding a generator to any type of power system provides additional peace of mind. For outside
plant communication networks, a generator serves as assurance that even in severe conditions,
you will be able to keep your system up and functioning. All AlphaGen™ systems are engineered
to have significantly reduced noise levels, high power density and status monitoring.
>AlphaGen Curbside Generator
The AlphaGen curbside generator system is specifically designed for outside plant communication
networks. Every AlphaGen system incorporates industry leading power technology, including:
automated operation of natural gas or propane powered engine generators, exclusive audible
noise baffling, remote status monitoring features and durable weather resistant enclosures. Alpha
offers a full line of AlphaGen systems specifically designed for easy integration into various power
supply designs.
>AlphaGen DCX 3000 Portable Generator
The Alpha generator family includes a portable 3.0kW DC generator. The compact, lightweight
AlphaGen generator is designed specifically for powering cable television, telecommunications
and other broadband applications that do not have integrated generators as a primary component
of the power system. The portable generator incorporates several technological advantages
including: ultra quiet operation, 36 or 48V selectable dual voltage output based on Permanent
Magnet Generator (PMG) technology, 3000W of power and oversized fuel tank for up to 20 hours
of runtime at 25% load or 7.2 hours at 100% load. Additional features include a convenient front
51
panel with a keyed on/off switch, output connector, output indicators, voltmeter, fuel valve and
engine choke.
>AlphaGen EU 2000 Portable Generator
specially qualified for use in the GEM system. The EU 2000 can be quickly installed or removed
from GEM enclosures, allowing for dynamic and flexible responses to power outages.
>AlphaGen Portable Generator Trailer
The AlphaGen Portable Generator Trailer, is a custom-designed trailer to store, transport and
deploy 28 AlphaGen generators and accessories. The trailer is 16ft long, has a 10,000lb GVWR
and is completely enclosed. For nighttime emergencies, the trailer includes battery-operated
interior lighting. The battery is always fully charged by a maintenance free solar panel charger. The
trailer sits on a 6 x 2 inch tubular steel frame and the trailer’s contents are protected with a
patented corrosion protection system. The rugged, industrial-grade running gear includes dual
Torflex rubber torsion axles with 16 inch radial tires, electric brakes, LED stop/tail/turn/marker
lights and a 7-pin electrical connector. An adjustable height hitch includes DOT chains and choice
of ball or pintle coupler.
Generators
The AlphaGen EU 2000 is a single cylinder, 4-stroke OHC, gasoline, portable AC generator
AlphaGen™ Curbside
Broadband Generator Systems
>Cost-effective extended runtime solution
for broadband powering applications
>Quiet operation, small size and low profile
allow for easy installation in populated areas
>Eliminates the large quantities of batteries
otherwise required for extended runtime
AlphaGen CE3x2-3G
AlphaGen Curbside
Output Rating:
3.5kW
5.0kW
7.5kW
39V ±0.5V @ no load 36V configuration
39V ±0.5V @ no load 36V configuration
52V ±0.5V @ no load 48V configuration
52V ±0.5V @ no load 48V configuration
52 ±0.5V @ no load 48V configuration
104V ±0.5V @ no load 96V configuration
DC Output Load Regulation:
0.5V
0.5V
0.5V
Output Current:
39V @ 90A max. / 52V @ 67A max.
39V @ 128A max. / 52V @ 96A max.
52V @ 144A max. / 104V @ 72A max.
DC Output Voltage:
398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel)
Engine:
2800 to 3600RPM
RPM (Variable Speed):
2800 to 3600RPM
2800 to 3600RPM
Acoustical Noise
Generators
52
dBA 10' @ 100% Rated Load:
68.7
68.5
70.3
dBA 20' @ 100% Rated Load:
63
62.5
64.3
dBA 10' @ 70% Rated Load:
68.3
66.9
66.4
dBA 20' @ 70% Rated Load:
62.6
60.9
60.4
Models:
CE-3x2
CE-9x2
CE-3x2
CE-9x2
PN-6x
Dimensions
H x W x D (in/mm):
44 x 26 x 24 /
1117.6 x 660.4 x
609.6
52 x 26 x 24 /
1320.8 x 660.4 x
609.6
44 x 26 x 24 /
1117.6 x 660.4 x
609.6
52 x 26 x 24 /
1320.8 x 660.4 x
609.6
39 x 39.3 x 24 / 914 x 998.2 x 609.6
(57 x 39.3 x 24 / 1447.8 x 998.2 x 609.6
with optional pedestal)
Weight (lb/kg):
383 / 174
413 / 187
383 / 174
413 / 187
338 / 174 (370 / 168 with optional pedestal)
APU Fuel Consumption
Natural Gas (1000BTU/Ft.3):
60ft3/hr
80ft3/hr
Propane Gas (2520BTU/Ft. ):
0.82gal/hr - 30ft /hr - 3.46lb/hr
1.10gal/hr - 40ft /hr - 4.62lb/hr
3
3
3
150ft3/hr
1.48gal/hr - 50ft3/hr - 6.24lb/hr
65°C / 149°F max (meets requirements of UL/CSA)
Exterior Surface Temperature:
All Models
AlphaGen Configuration Options
Gas Inlet Pressure:
0.5 to 2 PSI Inlet Pressure (Contact Alpha
Engineering for additional supply resources)
Ign Charger Voltage:
13.5Vdc
Ign Charger Current:
6A max.
Remote Interface Length:
75ft typical, distance depends upon installation,
de-rating and wire gauge.
Agency Compliance:
UL1778, UL2200, NFPA 37/54/58 and 70, CSA
C22.2 No.107.1, EMC/FCC Part 15 Class A
Fuel System, Controls
and Monitoring:
The controls and fuel system meet applicable
sections of NFPA 37, 54 and 58 for automatic
unattended operation of remotely located
generators. Full system control and status
monitoring included.
Sensors:
Gas hazard, pad shear, water intrusion and tamper
Safety Shutdowns:
Low oil pressure, over temp, low fuel pressure
shutdown (propane only), water intrusion,
pad shear, gas hazard (propane or natural gas),
over-speed, over-crank
Optional Feature:
Cold Start Kit: provides additional starting
capability at temperatures below -18°C / 0°F
CE-3x2 3.5 or 5kW
CE-9x2 3.5 or 5kW
CE-3/9G Propane Storage for Generator
(For 3.5 and 5kW)
PN-6x 7.5kW
(PN-6x is not compatible with CE-3/9G)
Portable AC and DC Generators
For Disaster Recovery and Preparedness
>DC technology requires no Automatic
Transfer Switch (ATS)
>No need to disconnect or reconnect power supply
>Super quiet operation: only 58dBA at 22ft/7m
AlphaGen DCX 3000
>Completely enclosed, water resistant
>Oversized metal gas tank with fuel level gauge
for extended runtimes of up to 20 hours
AlphaGen EU 2000
AlphaGen™ DCX 3000
Part Number:
041-028-10
Optional Accessories
Engine:
Honda GX 200 6.5hp, air-cooled, OHV, single
cylinder, manual recoil starting, manual choke
DCX-PG-WK:
Portable Generator Wheel Kit (P/N 745-793-20)
DCX-PG-HANDLE:
Locking Handle (P/N 745-792-20)
Rated Power:
2800W continuous, 3000W max.
AG-PG-TOOL:
Punch Tool Kit for Enclosures (P/N 745-131-20)
Alternator:
Permanent magnet, brushless, bearingless
AG-PG-UK:
Enclosure Upgrade Kit (P/N 745-131-21)
AG-CAB-KIT:
Cable Bag With Cable and Key Lanyard
(P/N 745-764-21-001)
Dual Range Selector
36V:
39.5Vdc nominal at generator output connector
48V:
52.5Vdc nominal at generator output connector
Output Regulation:
1Vdc
Control Features:
Automatic voltage regulation, electronic governor
over current protection, analog voltmeter with
back light
Cable Interface:
Anderson type SBE-80 connector
Fuel Tank:
3.4g / 12.8ltr metal tank with level gauge
Runtime
20hrs / 10hrs / 7.2hrs
Noise:
Approx. 58dBA @ 7m under full load
Frame:
Fully enclosed
Dry Weight (lb/kg):
Less than 118 / 53.5
Dimensions H x W x D (in/mm):
22.4 x 18.9 x 25.8 / 569 x 480 x 655
Agency:
CSA C22.2 No. 100-95, 107.1-01, 107.2-M89,
0.4 FCC part 15B Class A
Required Accessories
Output Interface Cable (m/ft):
Available in 3 / 10, 9.1 / 30 or 15.2 / 50 lengths
Battery Interface Cable:
Choose Ring Lung, Heavy-Duty Alligator Clamp,
or Y-adapter*
AlphaGen EU 2000
Specifications
The AlphaGen EU 2000 is a single cylinder, 4-stroke OHC, gasoline, portable
AC generator specially qualified for use in the GEM system. The EU 2000 can
be quickly installed or removed from GEM enclosures, allowing for dynamic and
flexible responses to power outages.
Output Voltage:
120Vac
Peak Rated Output:
2000VA
Continuous Rated Output:
1600VA
Noise Level:
53 to 59dBA
Net Weight (lb/kg):
46.3 / 21
Runtime:
4 to 15hrs
AC Line Transfer Switch
(Optional):
Can be connected to power supply using a Line
Transfer Switch (LTS) to automatically switch
power supply to generator power during outages.
53
30' Output Interface
10' P/N 875-324-22
30' P/N 875-324-20
50' P/N 875-324-21
Ring Lug Battery Interface
P/N 874-946-21
Alligator Clamp Battery Interface
P/N 874-946-20
Y-Adaptor Battery
P/N 874-946-22
Generators
@ 25% / 80% / 100% Load:
Accessories
* Connects the power supply’s battery input directly to the generator
AlphaGen™ Portable Trailer
Emergency Response and Disaster Recovery
>Securely holds 28 AlphaGen
portable DC generators
>Designed for storage and transportation of
gasoline powered generators
>Generator hoist allows for single person
deployment and recovery
AlphaGen portable trailer
>Customized 10,000lb trailer
When an emergency arises, service operations need to
respond immediately and the Alpha generator trailer enables
them to do just that.
These custom designed trailers eliminate generator storage
and transportation issues, while increasing emergency
preparedness. Designed to house, transport and deploy up
to twenty-eight AlphaGen portable generators, these trailers
are a proactive measure to ensure the necessary equipment
54
can be deployed immediately. Having the AlphaGen portable
generators fueled and ready to transport at a moment's notice
greatly reduces the duration of system outages, a critical
Choice of towing coupler on adjustable-height mount - 3" Pintle Ring or 2-5/16" Ball
Generators
component of network reliability.
24” Aluminum tread plate stone guard with wrapped integrated corners
Rear swing down ramp door with spring assist and non-skid surface
AlphaGen™ Portable Trailer
Emergency Response and Disaster Recovery
>All welded steel construction with space for additional materials
>Complete aluminum interior and diamond tread floor
>Internal lighting for nighttime deployments
>Bay lights and hoist powered by internal battery
system with solar maintenance charger
55
Generators
Portable generator racks securely hold 28 AlphaGen DCX3000 DC generators in transit
All-welded steel construction with shelving for additional materials
Generator hoist to raise and lower second shelf generators
Heavy duty rails provide smooth movement of units through trailer
AlphaCell® Batteries
Ensure optimal performance for your outdoor broadband, cable television and telecommunications
applications by incorporating AlphaCell batteries. With Alpha’s standby batteries, you don’t have to
worry about leakage, frequent replacements or cycling to obtain 100% capacity. They come ready
to support your network runtime expectations right out of the box. Whether it is the industry-leading
warranty, increased runtimes or maintenance-free threaded inserts, expect optimum performance
from AlphaCell batteries.
>AlphaCell HP
The AlphaCell HP brings pure lead technology to broadband power. Providing extended runtime
and up to 20% extended life expectancy, AlphaCell HP is the premium choice for your network.
AlphaCell 4.0 HP also provides potential operating expenditure reduction by reducing battery
string counts in situational applications.
>AlphaCell GXL
Alpha’s standby battery offering incorporates true GelCell and Silver Alloy grid battery
technologies, ensuring optimal performance for your outdoor cable, traffic or Wi-Fi application.
AlphaCell batteries provide the ultimate warranty, longest runtimes and superior longevity in
today’s demanding outdoor non-temperature controlled cable power environments.
>AlphaCell AGM
The AlphaCell batteries provide the ultimate warranties, the longest runtimes and the best
longevity in today’s demanding outdoor non-temperature controlled environments. AlphaCell AGM
57
batteries are an economical option for broadband, traffic and other indoor/outdoor UPS
applications. With a flame-arresting, one-way pressure-relief vent for safety and long life, and a
classified as non-hazardous material and are not restricted for air, water or surface transport.
>AlphaCell HPL-FT
The AlphaCell HPL-FT series batteries are constructed from a high performance lead alloy with
front terminals for use with Fiber Deep XM2-300HP and XM2-906HP power supply systems.
These batteries include a central gassing system, snap-in front covers, integral flame arrestor and
low self-discharge rates.
>AlphaGuard™
The AlphaGuard monitors and protects your batteries by spreading the charge voltage equally
across all batteries in the string, ensuring that every battery is properly charged. With an ideal
voltage across each battery, life and runtime are optimized. Individual batteries in a string can be
replaced as they fail, allowing good batteries to be left in service longer. This stops the wasteful
and costly practice of replacing complete battery strings based on a single battery failure.
>Battery Testing Equipment
A fast, reliable and affordable testing process is now available with the development of conductance
based battery measurement technology. By coupling conductance testing with a simple system load
or voltage test, the system operator is armed with the quality of data necessary to know the status of
their installed standby batteries and budget replacements with confidence.
AlphaCell Batteries
thermally welded case-to-cover bond to ensure a leak-proof seal, Alpha’s AGM batteries are
AlphaCell® 3.5HP and 4.0HP
Pure Lead Batteries
>Pure lead technology provides up to 20%
increased life expectancy
>Up to 6-year full warranty with XM3-HP
>Non-spillable UN2800 rating for ease of transportation
>4.0HP offering 240 cable runtime minutes
>String Count Reduction to Reduce OpEx
AlphaCell 3.5 and 4.0HP
You can use fewer AlphaCell HP batteries compared to standard batteries, while maintaining network runtime reliability. For power
supply loads that are less than 8 Amps you can achieve a 4 hour runtime using a single string of 4.0HP batteries, compared to using
two strings of competitive batteries. Consult your Alpha sales engineer for a free network analysis on how to potentially reduce your
OpEx by up to 25 percent while increasing the reliability of the batteries in your network.
AlphaCell 3.5HP and 4.0HP
Models:
3.5HP
4.0HP
Specifications
1
AlphaCell Batteries
58
Warranty:
5 to 6 year full replacement
5 to 6 year full replacement
Service Life:
Extended
Extended
Typical Runtime (minutes)2:
210
240
Sealed VRLA:
Valve regulated lead acid
Valve regulated lead acid
Heat Resistant:
Extreme
Extreme
Hydrogen Emission:
Low
Low
Terminals:
Threaded insert 1/4" - 20 UNC
Threaded insert 1/4" - 20 UNC
Electrical
Cell per Unit:
6
6
Voltage per Unit:
12.8
12.8
Conductance Value:
1700
2100
Max. Discharge Current (A):
800
900
Short Circuit Current (A):
2800
3200
10 Second Volts @ 100A:
11.7
11.8
Ohms Impedance 60Hz:
2.7
2.2
BCI Group Size:
31
31
Mechanical
Dimensions H x W3 x D3 (in/mm):
8.5 x 13.4 x 6.8 / 223.5 x 337.8 x 172.7
8.5 x 13.4 x 6.8 / 223.5 x 337.8 x 172.7
Weight (lb/kg):
68 / 30.8
74 / 35.6
Discharge:
-40 to 60°C / -40 to 140°F
-40 to 60°C / -40 to 140°F
Charge (with Temp compensation):
-40 to 60°C / -40 to 140°F
-40 to 60°C / -40 to 140°F
Float Charging Voltage (Vdc):
13.5 to 13.8
13.5 to 13.8
Operating Temperature Range
0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk
AC Ripple Charge:
Notes: 1 See AlphaCell Users Guide for additional details
2
Runtimes calculated using a 25A DC constant current load to 1.75Vdc @ 25°C
3
Dimensions at top of battery
AlphaCell HP Current Discharge Ratings in Amps
Hours*
3.5HP
4.0HP
End Voltage 1.75VPC:
1
2
3
4
8
10
20
70.2
40.3
28.6
22.3
12.1
9.9
5.2
End Voltage 1.70VPC:
72.0
41.1
29.2
22.7
12.3
10.0
5.3
End Voltage 1.75VPC:
81.9
45.8
32.2
25.0
13.1
10.6
5.7
End Voltage 1.70VPC:
83.7
46.7
32.8
25.4
13.3
10.7
5.8
AlphaCell HP Amp Hour Ratings
Hours*
3.5HP
4.0HP
End Voltage 1.75VPC:
1
2
3
4
8
10
20
70.2
80.6
85.8
89.2
96.8
99.0
104.0
End Voltage 1.70VPC:
72.0
82.2
87.6
90.8
98.4
100.0
106.0
End Voltage 1.75VPC:
81.9
91.6
96.6
100.0
104.8
106.0
114.0
End Voltage 1.70VPC:
83.7
93.3
98.3
101.5
106.3
107.0
115.8
* Use hours column above which closest models your desired runtime
AlphaCell® HP Runtime
Pure Lead Batteries
>3 to 5 times longer shelf life vs. standard VRLA
>Provides up to 50% increased runtime in
coldest climatesEfficiency VS. Temperature
AlphaCell 3.5HP and 4.0HP
100%
2.16
OCV Per Cell
90%
2.14
85%
2.13
80%
2.12
75%
2.11
2.1
Percent State of Charge
95%
2.15
40°C /
104°F
0
3
6
30°C /
86°F
9
12
25°C /
77°F
15
18
21
20°C /
68°F 70%
24
100%
Percent Rated Capacity Available
2.17
80%
60%
3.5HP
40%
Typical Gel
20%
0%
Storage Time (Months)
4.0HP
-40°F/
-40°C
-22°F/
-30°C
-4°F/
-20°C
14°F/
-10°C
32F/
0°C
50°F/
10°C
68°F/
20°C
86°F/
30°C
104°F/
40°C
AlphaCell HP Runtime XM3-HP (minutes)
90Vac @
4A
Model:
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
540
588
358
394
263
295
204
234
1264
771
841
574
624
450
491
6 batteries:
1144
90Vac @
12A
6A
8A
14A
10A
16A
Model:
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
165
193
137
164
116
142
6 batteries:
368
404
308
342
264
295
59
AlphaCell HP Runtime XM2-915, XM2-922 and GMX Runtime (minutes)
4A
Model:
3.5HP
4.0HP
6A
3.5HP
4.0HP
8A
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
490
533
310
344
229
260
182
211
4 batteries:
672
732
429
469
320
353
255
286
6 batteries:
1041
1146
672
732
504
548
404
442
8 batteries:
1413
1576
917
1006
691
752
556
605
9 batteries:
1601
1795
1041
1146
785
875
632
688
90Vac @
12A
14A
10A
16A
18A
Model:
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
146
174
118
144
100
124
87
109
4 batteries:
206
236
167
195
142
170
123
150
6 batteries:
329
363
268
300
229
260
200
230
8 batteries:
454
495
372
408
320
353
279
311
9 batteries:
518
563
424
463
365
401
320
353
Above calculations based on an AC load with a .92 cable plant power factor
60Vac @
4A
Model:
3.5HP
4.0HP
6A
3.5HP
4.0HP
8A
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
746
833
490
533
365
401
291
324
4 batteries:
1041
1146
672
732
504
548
404
442
6 batteries:
1601
1795
1041
1146
785
857
632
688
8 batteries:
2165
2465
1413
1576
1069
1178
864
946
9 batteries:
2448
2806
1601
1795
1212
1343
981
1078
60Vac @
12A
14A
10A
16A
18A
Model:
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3.5HP
4.0HP
3 batteries:
236
267
192
221
164
192
142
170
4 batteries:
329
363
268
300
229
260
200
230
6 batteries:
518
563
424
463
365
401
320
353
8 batteries:
709
773
583
635
504
548
442
482
9 batteries:
806
881
664
723
573
624
504
548
Above calculations based on an AC load with a .92 cable plant power factor
AlphaCell Batteries
90Vac @
AlphaCell® GXL
GelCell Batteries
>True Gel Silver Alloy minimizes grid corrosion
>Maintenance-free threaded inserts — no periodic retorquing
>Full-replacement, non-prorated warranty
AlphaCell 195 and 220 GXL
AlphaCell Broadband Batteries
AlphaCell Batteries
60
Models:
220 GXL
195 GXL
165 GXL
85 GXL-HP
195 GXL-FT
Warranty:
4 years
4 years
4 to 5 years
5 years
2 to 3 years
Service Life:
Extended
Extended
Extended
Extended
Long
Runtime (minutes)1:
221
196
165
85
195
VRLA Battery Type:
Gel Silver Alloy
Gel Silver Alloy
Gel Silver Alloy
Gel Silver Alloy
Gel
Heat Resistant:
Extreme
Extreme
Extreme
Extreme
High
Hydrogen Emission:
Low
Low
Low
Low
Low
Terminals:
Threaded insert 1/4" - 20 UNC
Threaded insert 1/4" - 20 UNC
Threaded insert 1/4" - 20 UNC
Threaded insert 10 - 32 UNF
16mm insert M6 thread
Cells Per Unit:
6
6
6
6
6
Voltage Per Unit:
12.8
12.8
12.8
12.8
12.8
Max. Discharge Current (A):
900
900
800
600
400
Short Circuit Current (A):
2800
2600
2500
2200
3000
10 Second Volts @ 100A:
11.4
11.3
11.2
10.8
10.8
Ohms Impedance 60Hz:
0.0050
0.0050
0.0055
0.0065
.0041
BCI Group Size:
31
31
27
22
N/A
Weight (lb/kg):
73 / 33.2
67 / 30.5
63 / 28.6
39.6 / 18
76.3 / 34.5
Dimensions
H x W2 x D2 (in/mm):
8.5 x 13.4 x 6.8 /
215 x 341 x 173
8.5 x 13.4 x 6.8 /
215 x 341 x 173
8.1 x 12.5 x 6.8 /
205 x 318 x 173
8.1 x 9 x 5.5 /
206 x 228 x 139
11.2 x 4.3 x 15.6 /
285 x 110 x 395
Operating Temperature Range
Discharge:
-40 to 71°C / -40 to 160°F
-40 to 71°C / -40 to 160°F
-40 to 71°C / -40 to 160°F
-40 to 71°C / -40 to 160°F
-40 to 71°C / -40 to 160°F
Charge (w/ temp compensation):
Float Charging Voltage
@ 25°C / 77°F (Vdc):
AC Ripple Charge:
-23 to 60°C / -9.4 to 140°F
-23 to 60°C / -9.4 to 140°F
-23 to 60°C / -9.4 to 140°F
-23 to 60°C / -9.4 to 140°F
-20 to 50°C / -4 to 122°F
13.5 to 13.8
13.5 to 13.8
13.5 to 13.8
13.5 to 13.8
13.6 to 13.8
0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk
Notes:
1
Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25°C / 77°F. 195GXL-FT runtime at 25A to 1.75VPC @ 25°C / 77°F.
10 cycles required to obtain maximum runtime charge
2
Dimensions at top of battery except for 195GXL-FT dimensions at battery base
AlphaCell GXL Current Discharge Ratings in Amps (End Voltage 1.75VPC)
Hours*
1
2
3
4
8
10
20
220GXL:
66.1
39.6
28.5
22.4
12.3
10.0
5.4
195GXL:
61.2
35.2
25.2
19.7
10.8
8.9
5.0
165GXL:
55.9
32.8
23.5
18.4
10.0
8.2
4.3
85GXL:
33.2
18.8
13.3
10.4
5.7
4.6
2.5
AlphaCell GXL Amp Hour Ratings (End Voltage 1.75VPC)
Hours*
1
2
3
4
8
10
20
220GXL:
66.2
79.2
85.5
89.6
98.4
100.0
109.0
195GXL:
61.2
70.4
75.6
78.8
86.4
89.0
100.0
165GXL:
55.9
65.6
70.5
73.6
80.0
82.0
86.0
85GXL:
33.2
37.6
39.9
41.6
45.6
46.0
50.0
* Use hours column above which closest models your desired runtime.
AlphaCell® GXL Runtime
GelCell Batteries
>Provides maximum runtime over the
life expectancy of the battery
>100% out-of-box capacity — no cycling required
>Industry leading runtime for VOIP networks
AlphaCell 165 GXL
XM3-HP Runtime (minutes)
90Vac @
Model:
4A
195GXL
220GXL
6A
195GXL
220GXL
8A
195GXL
220GXL
10A
195GXL
220GXL
12A
195GXL
220GXL
14A
195GXL
220GXL
16A
195GXL
220GXL
3 batteries:
6 batteries:
476
1026
550
1177
313
685
363
789
229
506
265
585
177
396
205
458
142
322
164
373
118
269
136
311
99
229
115
266
XM2-915, XM2-922 and GMX Runtime (minutes)
90Vac @
Model:
4A
220
195
165
6A
220
195
165
8A
220
195
165
10A
220
195
165
3 batteries:
4 batteries:
6 batteries:
8 batteries:
9 batteries:
508
701
1091
1487
1686
453
625
978
1338
1519
396
546
853
1165
1322
320
444
701
960
1091
285
396
625
859
978
249
346
546
750
853
236
329
523
720
820
209
293
465
643
733
193
256
407
562
640
186
261
418
577
659
165
232
372
515
587
144
203
325
450
514
90Vac @
Model:
12A
220
195
165
14A
220
195
165
16A
220
195
165
18A
220
195
165
3 batteries:
4 batteries:
6 batteries:
8 batteries:
9 batteries:
149
210
339
478
538
132
187
301
419
479
115
163
264
367
419
119
169
275
385
440
106
151
245
341
391
92
132
214
299
342
101
144
236
329
377
89
128
209
293
335
77
112
183
256
294
87
124
204
288
329
78
111
182
255
293
66
96
159
223
256
61
Above calculations based on an AC load with a .92 cable plant power factor
4A
220
195
165
6A
220
195
165
8A
220
195
165
10A
220
195
165
3 batteries:
4 batteries:
6 batteries:
8 batteries:
9 batteries:
798
1091
1686
2288
2590
712
978
1519
2067
2345
622
853
1322
1798
2037
508
701
1091
1487
1686
453
625
978
1338
1519
396
546
853
1165
1322
377
523
820
1122
1273
335
465
733
1006
1143
294
407
640
877
997
300
418
659
904
1027
267
372
587
809
921
233
325
514
706
803
60Vac @
Model:
12A
220
195
165
14A
220
195
165
16A
220
195
165
18A
220
195
165
3 batteries:
4 batteries:
6 batteries:
8 batteries:
9 batteries:
242
339
538
741
843
215
301
479
660
753
188
264
419
577
658
196
275
440
607
692
174
245
391
541
617
151
214
340
470
538
166
236
377
523
597
148
209
335
465
531
125
182
290
402
462
144
204
329
458
523
128
182
293
407
465
107
155
252
351
402
AlphaCell Batteries
60Vac @
Model:
Above calculations based on an AC load with a .92 cable plant power factor
XM2-300HP Runtime (minutes)
XM2-906HP Runtime (minutes)
Estimated Runtime
1A
2A
3A
4A
5A
6A
7A
8A
XM2-300 @ 90V
1A
1.5A
2A
2.5A
3A
85 GXL, 60V Runtime:
948
576
444
342
264
222
186
162
AlphaCell 70 HPL-FT:
249
167
120
91
71
85 GXL, 90V Runtime:
600
366
276
216
168
138
-
-
AlphaCell 85 GXL:
332
212
150
113
89
70 HPL, 60V Runtime:
774
474
366
282
228
186
168
138
AlphaCell 195 GXL:
684
442
317
241
191
70 HPL, 90V Runtime:
498
300
228
180
138
114
-
-
AlphaCell 4.0HP:
840
547
398
308
251
Runtimes based on one battery
115 HPL, 60V Runtime:
1200
756
582
456
354
300
252
222
115 HPL, 90V Runtime:
762
486
366
288
222
186
-
-
With XM2-906 and three batteries installed,
* Note: Battery temperature = 25°C / 77°F, Load PF = 0.92, Accuracy: 0.25 hour
AlphaCell 195 GXL-FT Runtime Specifications (minutes)
AlphaCell 195 GXL-FT Runtime Specifications (minutes)
XM2 90Vac @
6A
8A
10A
12A
14A
16A
18A
20A
XM2 60Vac @
6A
8A
10A
12A
14A
16A
18A
20A
3 batteries:
283
195
153
123
100
85
76
67
3 batteries:
467
325
246
195
163
142
123
107
4 batteries:
404
280
211
170
145
123
105
91
4 batteries:
648
467
353
281
230
194
170
153
6 batteries:
662
467
353
281
230
194
170
153
6 batteries:
1077
789
576
461
386
325
280
245
8 batteries:
960
654
501
403
331
280
242
211
8 batteries:
1447
993
847
654
541
461
403
353
Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell
@ 25°C / 77°F
Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell
@ 25°C / 77°F
AlphaCell®
Specialty Batteries
>AGM runtimes up to 160 minutes in outdoor cable applications
>Absorbent Glass Mat (AGM) technology
for efficient gas recombination
>HPL-FT features front terminal design with protective covers
>Specifically designed for mission critical applications
AlphaCell 220HPL-FT
AlphaCell AGM Batteries
AlphaCell HPL-FT Batteries
Models:
135 AGM-P
170 XLT
Models:
70HPL-FT
115HPL-FT
220HPL-FT
Warranty1:
4 year full replacement
1 year full replacement
Standard Warranty1:
3 years
3 years
3 years
Service Life:
Long
Average
Service Life:
Long
Long
Long
Runtime (minutes)2:
135
170
Runtime (minutes)2:
70
115
220
VRLA Battery Type:
AGM
AGM
VRLA Battery Type:
Heat Resistant:
High to moderate
Moderate
Heat Resistant:
High
High
High
Hydrogen Emission:
Low
Low
Hydrogen Emission:
Low
Low
Low
Terminals:
AlphaCell Batteries
62
Threaded insert 1/4" - 20 UNC
High performance Lead Alloy
Terminals:
14mm Insert M8 x 1.25 thread
Cells Per Unit:
6
6
Terminal Torque:
8Nm
8Nm
8Nm
Voltage Per Unit:
12.8
12.8
Case Material:
VO
VO
VO
Max. Discharge Current (A):
800
800
Cells Per Unit:
6
6
6
Short Circuit Current (A):
3100
3300
12.8
12.8
12.8
10 Second Volts @ 100A:
11.5
11.6
Ohms Impedance 60Hz:
0.005
0.004
1000
1000
1000
Capacity at 20hrs (to 1.75VPC):
75Ah
88Ah
1400
2000
3500
BCI Group Size:
24
27
Weight (lb/kg):
54.8 / 24.9
62 / 28
Voltage Per Unit:
Max. Discharge
Current (A):
Short Circuit
Current (A):
10 Second Volts
@ 100A:
11.3
11.5
11.7
Ohms
Impedance 1kHz:
6.5mOhms
4.1mOhms
2.5mOhms
Capacity @ 20hrs
to 1.75VPC):
42Ah
62Ah
107Ah
Weight (lb/kg):
Dimensions
H x W3 x D3 (in/mm):
27.9 / 15.3
8.21 x 3.81 x 9.84 /
209 x 97 x 250
46.2 / 22.2
10.3 x 4.2 x 11.3 /
263 x 103 x 287
78.5 / 36
11.3 x 4.2 x 15.6 /
36 x 108 x 396
Dimensions
H x W3 x D3 (in/mm):
8.02 x 10.26 x 6.83 / 203.6 x 260.5 x 173.4
Operating Temperature Range
Discharge:
-40 to 71°C / -40 to 160°F
Charge (with temp
compensation):
-23 to 60°C / -9.4 to 140°F
Float Charging Voltage
@ 25°C / 77°F (Vdc):
AC Ripple Charger:
13.5 to 13.8
13.5 to 13.8
0.5% RMS or 1.5% of float charge
voltage recommended for best results.
Max. allowed = 4%V pk to pk
Operating Temperature Range
Discharge:
Charge (with temp
compensation):
Float Charging
Voltage @
25°C / 77°F (Vdc):
AC Ripple Charger:
-40 to 60°C / -40 to 140°F
-40 to 60°C / -40 to 140°F
13.5 to 13.6
13.5 to 13.6
13.5 to 13.6
0.5% RMS or 1.5% of float charge voltage recommended
for best results. Max. allowed = 4%V pk to pk
Notes:
1
Warranty varies by country and region. Consult your sales person for details
2
Runtimes calculated using a 25A DC constant current load with voltage discharge
to 1.75V/ cell @ 25°C / 77°F
3
Dimensions at top of battery
Notes:
1
Warranty varies by country and region. Consult your sales person for details
2
Runtimes calculated using a 25A DC constant current load with voltage discharge to
1.75V/ cell @ 25°C / 77°F
3
Dimensions at top of battery
AlphaGuard™
Battery Charge Management System
>Maximizes battery life
>Spreads charge voltage equally across batteries
>Compensates for battery differences as they age
AlphaGuard CMT-3
>Replace single batteries, not the entire string
>Single battery connections for charge management and status monitoring
>Safe unattended operation designed to CSA C22.2
No. 107.1 and UL 1778 Standards
>Optional potted AlphaGuard for underground battery vault applications
Potted AlphaGuard CMT-3
AlphaGuard
Models:
Electrical
Batteries:
Individual 12Vdc nominal batteries configured
into 36 or 48Vdc strings
AlphaGuard Charge Management SC, 48V
—including 48Vdc battery string interface cable
Circuit Protection:
Fast blow fuse, reverse polarity protected
Quiescent Current Draw:
1mA max. (Current consumed by AlphaGuard
after low voltage total shutdown)
One (1) AlphaGuard is required per battery string
Charge Management:
Most effective during float period of charge
With the battery string
Max. Current:
2A @ 25°C / 77°F
Quality of Final Balance:
±100mV max. between any two (2) batteries
Charging Efficiency:
80 to 90%
Charge Balance:
±100mV typical
Low Voltage Cutoff:
34.5Vdc/46Vdc ±5%
Communication to XM2:
AG-DSM cable supplies battery readings to a
DSM status monitoring card
±100mV
AG-CMT-3:
AlphaGuard Charge Management SC, 36V
—including 36Vdc battery string interface cable
AG-CMT-4:
Configuration
Quantity:
Service Location:
Mechanical
Housing Material:
High impact plastic
Dimensions H x W x D (in/mm):
1.4 x 4.8 x 4.3 / 36 x 122 x 108
Weight (lb/kg):
0.8 / .36
Environment
-40 to 55°C / -40 to 131°F
Voltage Sense Regulation:
Humidity
5 to 95% non-condensing
Cables
5 years
AG-DSM-S9-Cable, AG-DSM-D9-Cable, AG-DSM-D35-Cable,
AG-DSM-S35-Cable, Battery Cable 36V 6ft, Battery 48V 6ft
Warranty
Warranty:
Battery Accessories
Operating Temperature:
Battery Testing Equipment
AlphaCell® Battery Testing Equipment
>Complete battery life trending through conductance tests
>Non-intrusive conductance measurements do not reduce string life
>Quick, accurate measurements and data recording reduce on-site time
>Simple pinpoint testing requires only access to two battery posts or straps
>Enables early detection of questionable batteries in the network
Celltron Essential
CTE-1200AT
Battery Testing Equipment
Model:
Celltron Essential
Celltron Advanced™
Environment
Model Number:
CTE-1200AT
(w/temp. sensor)
CTA-4000 (kit)
CTA-2000 (analyzer only)
Operating Temperature:
0 to 40°C / 32 to 104°F
Humidity:
95% non-condensing
Tests 6 and 12V
batteries with data
retention
Tests individual lead acid
cells or monoblocs (up
to 16V) in any common
configurations
Applications:
Voltage:
1.5 to 20Vdc
1 to 20Vdc
Conductance:
100 to 9999 Siemens
100 to 19990 Siemens
Test Data Storage:
Up to 144 consecutive
tests can be stored
internally
16 string locations of
480 test results stored
internally
Accuracy:
+2% across test range
+2% across test range
Voltmeter Resolution:
10mVdc
5mVdc
63
Kit Contents
Celltron Essential CTE-1200AT
Celltron Advanced Kit CTA-4000AT
Contains:
CTE-1200AT tester
PowerSure Software
Infrared PC data cable
Contains:
Protective boot
Rechargeable battery pack
Infrared PC data receiver and software
Infrared printer
Infrared temperature sensor
Protective carrying case
Both clamp and probe cables
Spare fuses, printer paper, probe tips
12V FlexPoint AX Series
Indoor/Outdoor Hybrid Solution
12V FlexPoint AX Series
Full Outdoor Solution
Operator Accessible Battery
Operator Accessible
Utility Meter
and Meter Base
BBPS
Indoor
Home
Converter
10.5 to 14Vdc
5-24 Watts
Typical Output
AC to DC
Power Converter
BBPS
ONT
Power & Remote Alarms
10.5 to 14Vdc
5-24 Watts
Typical Output
Fiber
Voice, Video
and Data Enters
Through Wall
11.6 to 16Vdc
Three Conductor
Low Voltage DC
ONT
Power & Remote Alarms
Fiber
Voice, Video
and Data Enters
Through Wall
11.6 to 16Vdc
Three Conductor
Low Voltage DC
Ground Rod
Ground Rod
48V FlexNet FMPS Series
Indoor Solution
48V FlexNet MPS Series
Indoor Solution
Operator Accessible Battery
Indoor
MPS
42 to 56Vdc
50 Watts
Typical Output
Operator Accessible Battery
ONT
Power & Remote Alarms
90 to 132Vac
Fiber
Voice, Video
and Data
Indoor
ONT
Fiber
Voice, Video
and Data
Power &
Remote Alarms
90 to 320Vac
Ground Rod
FMPS
42 to 58Vdc
150 Watts
Typical Output
ONT
Fiber
Voice, Video
and Data
Ground Rod
Fiber Power
Alpha Technologies offers a complete portfolio of Fiber-To-The-Home powering options with the
FlexPoint™ line of 12Vdc single-family unit solutions (SFU), and the FlexNet™ line of 48Vdc multiple
dwelling unit (MDU) and small office home office (SOHO) power supplies. All of Alpha’s powering
solutions are engineered to perform reliably in the most demanding environmental conditions while
optimizing battery life and performance.
12Vdc Solutions
>FlexPoint 1207-F for RFoG Applications
The indoor FlexPoint 1207, 7 Watt, 12Vdc standby power supply is an environmentally-hardened
standby power supply intended to be placed indoor or outdoor in sheltered locations. Its compact size
allows placement in the most densely populated structured medial enclosures. The FP1207 includes a
unique emergency battery reserve function that provides greater lifeline service availability by
preserving 25% of the usable battery capacity for user initiated emergency telephone calls. User
interfaces include visual status indicators, audible alarms, silence alarm button and an auxiliary 12Vdc
power input port allowing additional battery capacity to be added for longer standby runtimes.
>Integrated Fiber Enclosure (IFE)
The FlexPoint IFE-A30-1 Integrated Fiber Enclosure from Alpha Technologies provides a reliable,
compact and cost-effective means to simplify RFoG deployment. The enclosure contains a fiber
management system, an 8-way coaxial splitter and a FlexPoint power supply with provisions for
installing RFoG devices. The door-mounted FlexPoint power supply provides 20 hours of battery
backup runtime. The enclosure is lockable, making this system a secure and convenient solution for
Micro Node management.
>FlexPoint AX Series for EPON/GPON and RFoG
48Vdc Solutions
>FlexNet MPS48-7 Series
Alpha extends its family of FlexNet element powering solutions to include the MPS48-7F and
MPS48-7T multipurpose power supplies. The MPS48-7F supports fiber-to-the-home applications
including MDU, MTU and SBU ONT products. The MPS48-7T supports critical network
communication loads. These units are indoor or outdoor, wall or pole mounted microprocessor
controlled UPS systems providing 50 Watts of 48Vdc. The input is powered from 120, 240 or higher
AC voltages with an optional step-down transformer. A 48Vdc string of standard 7.2Ah maintenance
free sealed lead acid batteries provide standby power.
>FlexNet FMPS
The FTTx Multipurpose Power Supply (FMPS) is an indoor/outdoor system providing 150W of 48Vdc
power to MDU and SOHO optical network terminals. The FlexNet FMPS is an environmentally
hardened wall mount enclosure system with dual ONT connections supported with one or two 48Vdc
strings of 7.2Ah batteries. The system includes one or two parallel outputs and alarm connections,
supporting distances of up to 100ft between the FMPS and ONT, allowing the FMPS to be located
close to existing power outlets.
>FlexNet FiberUPS®
The FlexNet FiberUPS is a 300W, 48Vdc battery backup power module supporting a variety of indoor
and outdoor applications. With pole, wall or ground mount enclosure options, the FlexNet FiberUPS will
keep field distributed electronics up and running during power disturbances and outages.
>PMR and GMR Series
The PMR and GMR series are comprised of two sizes of pole mount and two sizes of ground mount
factory configured and regulatory certified rainproof enclosure systems. PMR and GMR are highly
configurable systems including 19" adjustable or pullout swing racks, AC service entrance and
distribution, surge suppression, fiber management, power bypass cabling, FiberUPS DC power
supply, DC distribution and 50Ah AlphaCell® batteries.
65
Fiber Power Systems
The indoor/outdoor FlexPoint AX Series, 30 Watt, 12Vdc fiber-to-the-premises optical network terminal
(ONT) power supply system, provides network operators a highly reliable, scalable set of solutions
for full or partial outdoor RFoG and PON installations. This system provides service technicians 24/7
access to the power system. FlexPoint AX home converters and power ring converters provide
12Vdc support for indoor and outdoor applications not requiring standby power. As services expand
to include voice or critical data support, 7.2 or 17Ah battery backup power supplies (BBPS) can be
easily added.
FlexPoint™ 12Vdc
RFoG Battery Back Up Power Supplies
>Supports expanding services
>Indoor and outdoor applications
>24-Hour operational access to outdoor solutions
>Safe, low-voltage distribution
AX HC/BBPS-F
1207-F 7W RFoG System with Primary and Standby Power
Specifications
FPR1207-F7.2 — Indoor 12V 7W Power System
Input:
85 to 264Vac (45-66Hz)
Output Voltage:
10.5 to 14.4Vdc
Output Power:
7 Watts
Number of Batteries:
One 7.2Ah battery
Battery Backup Runtime:
Approx. ~ 20hrs w/ 3.5W load,
Approx. ~ 12hrs w/ 7W load
Status Indicators:
Visual and audible
Dimensions H x W x D (in/mm):
Weight (lb/kg):
66
7.75 x 8.75 x 3 / 177 x 224 x 76.2
Unit
1.3 / 0.59
Battery
5.7 / 2.6
Backup Power for Business Service RFoG Deployment
Integrated Fiber Enclosure (IFE) — For RFoG Deployment
Fiber Power Systems
Specifications
Battery Backup Runtime:
Approx. ~ 20hrs w/ 3.5W load,
Approx. ~ 12hrs w/ 7W load
Coaxial Management:
8-Way Coax Splitter
Fiber Management:
Fiber wrap spool 12-fiber splice tray
Features:
Lockable, secure indoor enclosure
Dimensions H x W x D (in/mm):
12 x 12 x 8 / 304.8 x 304.8 x 203.2
Weight (lb/kg):
8 / 3.6
AX 30W RFoG System with Primary and Standby Power
AX HC/BBPS-F — Outdoor 12V 30W Power System
Specifications
Input:
85 to 132Vac
Output Voltage:
10.5 to 14.4 Vdc
Output Power:
30 Watts
Mounting:
Partial outdoor
BBPS-F Dimensions H x W x D (in/mm):
7.75 x 8.75 x 3 / 177 x 224 x 76.2
Weight (lb/kg):
3 / 1.4
Home Converter Dimensions
H x W x D (in/mm):
8.5 x 3 x 2 / 21.5 x 7.6 x 5
Home Converter Weight (lb/kg):
1 /.45
Home Converter
Application
AX RFoG Indoor Powering - UPS
Operational Temperature Indoor Range: -40 to 113°F (-40 to 45°C
Operational Temperature Outdoor Range: -40 to 113°F (-40 to 45°C)
RFoG Device
BBPS-F
FlexPoint™ AX 12Vdc
PON Battery Back Up Power Supplies
>Full or partial outdoor configurations
>Outdoor rated BBPS including
battery for 24/7 availability
>Utility meter base provides most reliable
source of AC power at home
FlexPoint AX Series
AX 30W EPON/GPON System with and without Standby Power
Specifications
AX PC/BBPS — Outdoor 12V 30W System
Input:
170 to 264Vac
Output Voltage:
10.5 to 14.4Vdc
Output Power:
30 Watts
Mounting:
Outdoor
BBPS Dimensions H x W x D (in/mm):
7.75 x 8.75 x 3 / 177 x 224 x 76.2
Weight (lb/kg):
3 / 1.4
Power-Ring Dimensions H x Dia (in/mm): 4.75 x 7 / 120 x 178
Power-Ring Weight (lb/kg);
1.5 / 0.68
Power Converter Dimensions
H x W x D (in/mm):
8 x 2 x 2 / 209 x 51 x 51
Power Converter Weight (lb/kg):
0.7 / 0.32
Power-Ring
Home Converter
BBPS
67
Applications
AX PON Outdoor Powering – Non-UPS
AX PON Outdoor Powering – UPS
Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F
AX 30W EPON/GPON System with and without Standby Power
Specifications
AX HC/BBPS — Indoor / Outdoor 12V 30W Power System
Input:
85 to 132Vac
Output Voltage:
10.5 to 14.4Vac
Output Power:
30 Watts
Mounting:
Partial outdoor
BBPS Dimensions H x W x D (in/mm):
7.75 x 8.75 x 3 / 177 x 224 x 76.2
Weight (lb/kg):
3 / 1.4
Home Converter Dimensions H x W x D (in/mm): 8.5 x 3 x 2 / 21.5 x 7.6 x 5
Home Converter Weight (lb/kg):
1 /.45
Home Converter
BBPS
Applications
AX PON Indoor Powering – Non-UPS
Operational Temperature Range: -40 to 45°C / -40 to 113°F
AX PON Indoor Powering – UPS
Operational Temperature Indoor Range: -40 to 45°C / -40 to 113°F
Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F
Fiber Power Systems
Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F
FlexNet™ 48Vdc 50W
Battery Back Up Power Supplies
>Rugged outdoor or indoor 48Vdc 50W wall or pole mount UPS
>Aesthetically pleasing, minimizes presence in public locations
>Optional compensated battery charging for optimum battery life
>Local and remote status monitoring and reporting
FlexNet MPS48-7 Series
FlexNet MPS48-7 Series
FN50-48-7F — With Output Interface Module-F
Specifications
Fiber Power Systems
68
Input:
90 to 132 or 180 to 264Vac
Output Voltage:
42 to 56Vdc
Output Power:
50 Watts continuous
Output Interface Module-F:
Packet Cable Alarms
Output Interface Module-T:
Dry Contact Alarms
Unit Dimensions
H x W x D (in/mm):
4.18 x 8.75 x 2.12 /
106.17 x 222.25 x 53.84
Weight (lb/kg):
1.5 / 0.68
System Dimensions
H x W x D (in/mm):
17.5 x 12.75 x 5.25 /
445 x 324 x 133
Weight (lb/kg):
11 / 4.9, 34.6 / 15.7 w/ batteries
Number of Batteries:
Four 7.2Ah Valve Regulated Lead
Acid (VRLA)
Runtime:
18 Hours @ 20W load,
8 Hours @ 40W load
FN50-48-7T — With Output Interface Module-T
FlexNet™ 48Vdc 150W
Battery Back Up Power Supplies
>FTTP outdoor UPS for Multiple Dwelling, Multiple
Tenant and Small Business Unit applications
>Battery management performs periodic battery capacity
testing and status reporting to the ONT and customer
>Battery heater option provides extended runtime for
applications in cold weather conditions
>Status indicators and audible alarm provide local reporting
FlexNet FMPS
FLexNet FMPS
Specifications
Input:
90 to 320Vac
Output Voltage:
42 to 58Vdc
Output Power:
150 Watts continuous
FMPS Dimensions
H x W x D (in/mm):
23.75 x 14 x 5.5 /
603.25 x 355.6 x 139.7
Weight (lb/kg):
25 / 11.3
Number of Batteries:
Four or eight 7.2Ah
Valve Regulated Lead Acid (VRLA)
FlexNet™ 48Vdc 300W
Battery Back Up Power Supplies
>300W 48Vdc UPS for outdoor or indoor applications
>Power modules can be used in a variety of Alpha enclosures
>Temperature compensated battery
charging for extended battery life
FlexNet ELPM-300
>Flexible cabinet mounting
>Visual and electrical indicators for on-site and remote reporting
FlexNet ELPM-300
Specifications
LPE and ELPM-300 — 300W for MDUs, Dark Spots and Business Parks
Input:
85 to 170 or 132 to 264Vac selectable
Frequency:
50 or 60Hz
Output Voltage:
42 to 54Vdc
Output Power:
300 Watts
Dimensions H x W x D (in/mm):
6 x 10.1 x 3.25 / 152 x 256.5 x 82.6
Weight (lb/kg):
10 / 4.5
Number of Batteries:
Four 12Vdc 50Ah (85GXL)
Approx. Backup Time:
8 Hours @ 275W load
LPE and FlexNet ELPM-300
Specifications
69
26 x 16.5 x 12 / 661 x 420 x 305
Enclosure Weight (lb/kg):
25 / 11.3
Material:
Exterior powdercoated aluminum
Number of Batteries:
Four 12Vdc 17Ah
Door and Lid Seal:
Poron gasketing
Approx. Backup Time:
4 Hours at 250W load
PMR and GMR Series
Specifications
PMR-S1 Dimensions H x W x D (in/mm):
32.2 x 26 x 19.25 / 818 x 660 x 489
Weight (lb/kg):
40 / 18
GMR-S1 Dimensions H x W x D (in/mm):
31 x 27.5 x 20 / 787 x 699 x 508
Weight (lb/kg):
49 / 22
PMR-S2 Dimensions H x W x D (in/mm):
37 x 30 x 19.25 / 940 x 762 x 489
Weight (lb/kg):
47 / 21
GMR-S2 Dimensions H x W x D (in/mm):
38 x 31 x 20 / 965 x 787 x 508
Weight (lb/kg):
63 / 29
Number of Batteries:
Four 12Vdc 50Ah (85GXL)
Approx. Backup Time:
8 Hours at 275W load
Enclosure Mounting and
Door - PMR Series:
Galvanized steel brackets for wood, and
concrete pole mount and wall mount
Enclosure Mounting and
Door - GMR Series:
Precast polymer concrete pad or
PS-6/PS-6XL pedestal systems
Fiber Strain Relief Tie Bar Optional:
19" mounting provides ability to strain
relief fiber cable plugged into the front
of communications equipment
Splice Tray:
Splice Tray Kit (12 count), includes
Splice tray with elastomer splice
block, felt tape, tie wraps, cover and
recording label
Fiber Management Panel:
Provides fiber slack storage and
secures a splice tray using a Velcro
strap. Tie wrap slots on sides permit
securing fiber cables to panel
PMR and GMR Series — 300W for field deployment of
TTx Optical Line Terminal (ONT)
Fiber Power Systems
Enclosure Dimensions H x W x D (in/mm):
Wireless and Fiber Backhaul
>5RU to 80RU enclosures available
>High efficiency AC/DC powering options
>Thermoelectric cooling, heat exchanger or air conditioning
>Reduce installation time with optional power and optical integration
>Turn-key installation and preventative maintenance services
To support the growing demand for wireless carrier backhaul services, Alpha offers a
comprehensive range of fully integrated backup powering solutions, including time-tested
enclosures and power supplies.
Designed to UL, NEMA or GR478 requirements, Alpha enclosures are an all-in-one solution to
your backhaul and powering needs. The modular design allows you to claim valuable real estate
now and expand your powering options in the future.
>Flexible Backhaul Enclosure
Alpha’s Flexible Backhaul Enclosure (FBE) is engineered to house optical fiber equipment to
support high speed cellular data backhaul. Built with eleven rack mount spaces, the Alpha
FBE is able to house fiber and powering gear including an Ethernet switch, power inverters,
rectifiers, fiber splice tray, GMT and additional controls. An optional configuration enabling the
addition of batteries, DC rectifiers and Service Utility Entrance is available. With Telecom-grade,
71
quarter-turn locks and key-operated Demark access, the FBE offers easy maintenance access
>Wireless Transport Enclosure
The Wireless Transport Enclosure (WTE) is ideal for Wireless Backhaul Business Services
applications. It offers a self-contained total power solution for a wide range of applications including
wireless outdoor base stations, wireless IP access and bulk power. With a compact 24” x 24”
footprint, the WTE features a standard 19” rack mount system with 17RU (front/rear) of rack space
and an internal Breaker Distribution Panel with GFCI and surge protection.
>Te4(x)
Alpha introduces its newest enclosure line, Te40, Te41 and Te45 Power Enclosures. Ranging
from 84-inches tall (Te40, Te41) to 72-inches tall (Te45), all are third-party agency certified to meet
GR-487 requirements (Zone 1 seismic and 70mph wind driven rain) and configurable to a range of
different power and installation scenarios.
Wireless and Fiber Backhaul
and complete security.
Flexible Backhaul Enclosure 2322
>Provides 15RU for 19" horizontal mounted equipment
or 10RU for vertical mounted equipment
>Front and side door access with removable lid
>Durable welded aluminum construction
>Wall, H-Frame, pole or ground mount options
>Multiple thermal management options
FBE2322-ENC
FBE2322-ENC
System Options
Specifications
Outer Dimensions
H x W x D (in/mm):
29.6 x 27 x 24 / 751.84 x 685.8 x 609.6
Equipment Space:
Front to back adjustable 19" 15RU horizontal
or 23" 10RU vertical
Access:
Front hinged door, left and right lift off doors,
removable lid
Mounting:
Wall, H-Frame, ground or precast mounting pad
Thermal:
Air conditioner with heater, heat exchanger, fan
cooled with variable speed-control
Emergency Ventilation
System:
Fan cooled with variable speed-control activated
with high temp or HVAC fail alarm
DC Power:
48Vdc Cordex HP 1.2kW rectifiers
70Amp 2 position or 100Amp 8 position
Door Latch / Hinge Type:
1/4 turn padlockable / reversible 2 position
lift off hinge
AC Services Entrances:
Generator:
External L14-30P generator plug
CSA/UL:
60950-22 ITE electrical enclosure
Alarm:
Alarm terminal block
NEMA Rating:
Type 3R
72
Wireless and Fiber Backhaul
Enclosure Options
FBE Modular Design
CordexHP 1.2kW
48Vdc Modular Switched Mode Rectifier
Multiple 48V configurations up to 125 Amps
for various 48Vdc applications
High Efficiency design for increased
OpEx savings
High Temperature rated fan-cooled design
for harsh outdoor installations
Cordex 4R/8D ADIO
1
Enclosure Lid
2
Auxiliary Equipment
Enclosure
3
Base Equipment
Enclosure
4
Battery Expansion
Enclosure
5
10” Plinth / Mounting
Options
6
Climate Control Options
CXC Smart Peripheral
Provides additional I/O expansion to existing
CXC site controller
Seamless expansion of four relay outputs
and eight digital inputs
Ideal for alternate device monitoring and
control such as HVAC and generators
1
2
3
Fuses Panels
Stand-Alone DC Distribution
19" and 23" rack mount models
12, 24 or 48V configurations
Designed for flexible and custom DC distribution
AlphaCell®
4
HPL-FT Batteries
AGM runtimes up to 160 minutes in
outdoor applications
Absorbent Glass Mat (AGM) technology
for efficient gas recombination
HPL-FT features front terminal design
with protective covers
Specifically designed for mission-critical applications
5
Flexible Backhaul Enclosure 2319
>Modular enclosure system, allows
for easy battery expansion
>Demark access door
>Front access for fan and filter maintenance
>24 or 48V configurations
FBE2319-ENC with Demark
access door and fan cool option
FBE2319-ENC
Specifications
Models:
FBE2319-ENC
FBE2319-ENC with
Battery Enclosure
Outer Dimensions
H x W x D (in/mm):
27 x 23 x 22.3 /
686 x 584 x 565
41 x 23 x 22.3 /
1041 x 584 x 565
Weight (lb/kg):
57 / 26
82 / 37.5
Equipment Space:
Front to back adjustable 19" 11RU
Access:
Front hinged door with demark access door
Door Latch / Hinge Type:
1/4 Turn padlockable / reversible 2 position lift off hinge
CSA/UL:
60950-22 ITE electrical enclosure
NEMA Rating:
Type 3R
System Options
Wall, H-Frame, Ground or Precast Mounting Pad
Thermal:
Heat exchanger, fan cooled with variable speed-control
DC Power:
48Vdc Cordex HP 1.2kW rectifiers
AC Services Entrances:
70Amp 2 position or 100Amp 8 position
Generator:
External L14-30P generator plug
Alarm:
Alarm terminal block
73
FBE2319-ENC with Heat Exchanger Door,
Battery Expansion and Ground Mount Option
Flexible Backhaul Enclosure 1417V
>Provides 7RU for 19" vertically mounted equipment in
smallest footprint possible
>Front and side access to installed equipment
>Wall or H-frame mount options
>Aluminum welded construction with durable powdercoated exterior
>Fan cooled with variable speed-control
FBE1417V-ENC
FBE1417V-ENC
Specifications
Outer Dimensions
H x W x D (in/mm):
24.6 x 18 x 19.5 / 625 x 452 x 495
Weight (lb/kg):
35 / 15.9
Equipment Space:
Vertical 19" 7RU
Access:
Front hinged door, left and right lift off doors
Door Latch / Hinge Type:
1/4 Turn padlockable / reversible 2 position lift off hinge
CSA/UL:
NEMA Rating:
60950-22 ITE electrical enclosure
Type 3R
System Options
Mounting:
Wall or H-Frame
Thermal:
Fan cooled with variable speed-control
1RU Option Panel:
Alarm terminal block, fiber management
FBE1417V-ENC
Wireless and Fiber Backhaul
Mounting:
Wireless Transport Enclosure
>Equipment mounting area is 17RU
>Equipment rails are front-to-back adjustable, suitable
for mounting 19 inch rack mount equipment
>Integrates Heat Exchanger and Thermoelectric Cooling System
>Equipment area is cooled by an air-to-air heat
exchanger with variable speed blower control
>Internal L14-30P generator inlet plug with
generator cord access through door
>Optional precast mounting pad
Wireless Transport Enclosure
Wireless Transport Enclosure
Specifications
Wireless and Fiber Backhaul
74
System Specifications (As Shown)
Outer Dimensions
H x W x D (in/mm):
70 x 24 x 29 / 1778 x 610 x 737
Weight (lb/kg):
330 / 150
Equipment Space:
Adjustable 19" 17RU plus 2 battery trays
Access:
Front hinged door and rear lift off door
Door Latch / Hinge Type:
1/4 turn padlockable / reversible 4 position
lift off hinge
CSA/UL:
60950-22 ITE electrical enclosure
NEMA Rating:
Type 3R
• Dual compartments
- Upper compartment - heat exchanger
- Lower compartment - thermoelectric cooling
• Two battery trays (Consult factory for battery specifications)
• Front to back adjustable 19" equipment mounting rails
• Internal AC panel
• Generator plug and transfer switch
• Alarm terminal block
• Ground bar
System Options:
Optional precast mounting pad
Consult factory for custom system solutions
Tempest Te45 Backhaul Enclosure
72" Single Compartment Power Enclosure
>Designed for single or multiple enclosure applications
>Durable welded aluminum construction
>Variety of configurations possible with 39RU of space
>Compact footprint and optional precast mounting pad
>GR-487 compliant
Tempest Te45 (open)
Tempest Te45 Backhaul Enclosure
Specifications
System Specifications (As Shown)
Dimensions H x W x D (in/mm):
72 x 30 x 30 / 1829 x 762 x 762
Weight (lb/kg):
600 / 273
Equipment Space:
23" 39RU
Access:
Removable rear panels and front hinged door
Door Latch / Hinge Type:
3 point latch / 4 position lift off hinges
Handle:
Padlockable
Battery Trays (Qty):
Configuration dependent - 8RU per front
terminal battery shelf
CSA/UL:
C22.2 No. 60950
NEMA Rating:
Type 3R (CSAC22.2 No 94-M91)
• 48Vdc Cordex 1.8kW rectifiers
• AC panel c/w generator panel and ATS (Automatic Transfer Switch)
• Air conditioner w/ heater
• EVS (Emergency Ventilation System)
• Alarm terminal block
• Ground bar
• Precast Mounting Pad available. See page 50
System Options:
Consult factory for custom system solutions
Tempest Te40 Backhaul Enclosure
84” Front Terminal Battery Enclosure
>10 Strings at 24Vdc, 5 strings at 48Vdc
>120Amp buss
>Designed for single or multiple enclosure applications
>Durable welded aluminum construction
>Compact footprint and optional precast mounting pad
Tempest Te40 Battery
Tempest Te40 Backhaul Enclosure
Specifications
System Specifications (As Shown)
Dimensions
H x W x D (in/mm):
84 x 30 x 30 / 2134 x 762 x 762
Weight (lb/kg):
1300 / 590
Equipment Space:
23" 44RU
• 5 battery shelves for GNB 155Ahr front terminal batteries
• Air conditioner w/heater
• Alarm terminal block
• Ground bar
• Precast Mounting Pad available. See page 50
Access:
Removable rear panels and front hinged door
System Options:
Door Latch / Hinge Type:
3 point latch / 5 position lift off hinges
Agency Standards:
C22.2 No. 60954
NEMA Rating:
Type 3R (CSAC22.2 No 94-M91)
Consult factory for custom system solutions
75
Wireless and Fiber Backhaul
Tempest Te41 Backhaul Enclosure
84" Dual Compartment Power Enclosure
>Designed for single or multiple enclosure applications
>Dual compartment system
>Durable welded aluminum construction
>Variety of configurations possible with 23RU of space
>Compact footprint and optional precast mounting pad
>Up to 39.6kW at 48Vdc or 34.1kW at 24Vdc
>Multiple point cable access
Tempest Te41 Power
Tempest Te41 Backhual Enclosure
Specifications
System Specifications (As Shown)
Dimensions
H x W x D (in/mm):
84 x 30 x 30 / 2134 x 762 x 762
Weight (lb/kg):
1300 / 590
Equipment Space:
23” 19RU (upper), 26RU (Lower)
Access:
Removable rear panels and front hinged door
Door Latch / Hinge Type:
2 point latch upper and lower compartments /
5 position lift off hinges
Agency Standards:
C22.2 No. 60953
• 48Vdc Cordex 3.6kW rectifiers (3.1kW Cordex system optional)
• Qty 48 DC breaker positions
• Qty 4 LVD disconnects for staged shutdown during power outage
• AC panel c/w generator panel and ATS (Automated Transfer Switch)
• Air conditioner w/ heater
• Fan/filter ambient cooled upper compartment
• Customer specific equipment layout
• Alarm terminal block
• Ground bar
• Precast Mounting Pad available. See page 50
NEMA Rating:
Type 3R (CSAC22.2 No 94-M91)
System Options:
Consult factory for custom system solutions
Alpha Technologies Inc.
3767 Alpha Way
Bellingham WA 98226
United States
Tel: +1 360 647 2360
Fax: +1 360 671 4936
VISIT US AT WWW.ALPHA.COM
Alpha Technologies
Due to continuing product development, Alpha reserves the right to change specifications without notice.
Copyright © 2011 Alpha Technologies Inc. All Rights Reserved.
Alpha is a registered trademark of Alpha Technologies. 049-360-10-A002 (09/2012)