dynascope - Fukuda Denshi

Transcription

dynascope - Fukuda Denshi
DD S - 7 0Y0 0 NS E R I AE S MSO N I TCO R I NOG S PY S T EEM
W M T S
T E L E M E T R Y
T R A N S M I T T E R
L X - 7 2 3 0 N
The LX-7230N is a state-of-the-art patient worn telemetry transmitter
featuring a "Quick View" LCD display screen that allows for immediate
"Point of Care" visual confirmation of everything from electrode status
to battery strength.
strength
Nellcor® Pulse Oximetry
Pacemaker Detection
ECG / SpO2 Waveforms & Numerics
Lightweight Design (7 oz)
Patient Event Button
2.5 Days of Continuous Operation
on Two AA Batteries
3, 4 or 5 Lead ECG Cables
IPX8 Waterproof
LX-7230N Specifications
Standard Specification
ECG
Size
72.0mm (W) x 98.0mm (H) x 24.8mm (D)
(2.8" (W) x 3.8" (H) x 1.0" (D))
Numbers of
Lead Electrode
3 / 4 / 5-electrode
Weight
APX. 190 grams (6.7 oz)
Numbers of
Input Channel
1 CH or 2 CH
Transmitting
Waveform
ECG 1CH or 2CH, Respiration waveform, pulse waveform
Accuracy of Sensitivity
10 mm / 1 mV ± 20 %
ECG Lead
Cable Type
3-electrode, 4-electrode, or 5-electrode lead cable
HR, RR, PR, SpO2 value
ECG Input Impedance
5M
Transmitting
Status Data
Electrode Off, Low Battery, Event Switch, Pacemaker
Detection, Channel ID, 64group Codes, SpO2 Sensor Off
Maximum Input Voltage
± 5 mV and above
Less than 10 mVp-p (95 dB and above)
LCD
Built-in
Common Mode
Rejection Ratio
Waterproof
IPX8
Accuracy of Heart Rate
Measurement
± 10 % or ± 5 bpm, whichever is greater
Battery Supply
Two 1.5 V "AA" size
Continuous
Operating Time
HR Display Range
0, 12 to 300 bpm
APX. 2.5 days
Frequency Characteristic
0.5 to 40 Hz (within -3 dB)
Time Constant
0.4 sec. ± 25 %
Pacemaker Pulse
Detection / Rejection
Comply with ANSI/AAMI EC13 Pacemaker pulse
rejection capability
Defibrillation Protection
Yes / Meets the requirements of IEC60601-2-27
Respiration (Impedance Method)
Accuracy of
Sensitivity
10 mm / 1
Resp. Display
Range
0, 9 to 150 bpm
Display Error of
Respiration Rate
± 3 bpm
Measured Current
of Respiration
Below 100 A (at 42 kHz)
± 2 mm
Pulse Wave
SpO2
SpO2 Measurement
Range
1 to 100 %
Resolution
1%
Measurement
Accuracy
(Nellcor®
Technology)
SpO2 Probe
Measurement Accuracy
(± 1SD)
OxiMax® MAX-I
OxiMax® MAX-P
OxiMax® MAX-A/AL
Durasensor® DS-100A
OxiMax® MAX-R
OxiMax® MAX-FAST
OxiMax® MAX-N
(Less than 70 % is not specified)
Measurement
Response Time
Measurement
Value Update Rate
and above
±
±
±
±
±
±
±
2%
2%
2%
3%
3.5 %
2%
2%
Transmission Method
Frequency
608 to 614 MHz
Oscillation Method
Measurement
Accuracy
± 3 bpm
Measurement
Response Time
6 to 7 sec. (Averaging time)
Measurement
Value Update Rate
1 second
General Standard
IEC60601-1:1988 + A1: 1991 + A2: 1995
EMC Standard
IEC60601-1-2: 2007
Shock Hazard
Type CF Applied Part
Operating Environment
1 second
Digital
20 to 250 bpm
Safety
6 to 7 sec. (Averaging time)
Modulation Mode
Pulse Rate
Measurement Range
Temperature
10 to 40 °C
Humidity
30 to 85 % RH (No condensation)
Vibration/Shock
Comply with IEC60068-2-64:1987,
IEC60068-2-32:1975, IEC60068-2-6:1995
Transport / Storage Environment
Temperature
-10 to 60 °C
PLL Synthesizer method by crystal control
Humidity
10 to 95 % RH (No condensation)
Channel Spacing
12.5 kHz
Standard Accessories
Occupied Frequency
Bandwidth
8.5 kHz
RF output power
1 mW ± 2 dB
Transmitting Antenna
ECG lead cable and/or SpO2 Probe
Neck Strap
OA-311
4-electrode lead cable
CMT-02HTH-0.8DA
Operation Manual
ECG Monitoring
3-electrode lead cable
1 waveform
White
(RA)
Black
(LA)
4-electrode lead cable
2 waveforms
White
(RA)
Green
(RL)
Red
(LL)
Cable: CMT-01HTH-0.8DA
ECG 1: lead I, lead II, or lead III
Black
(LA)
Red
(LL)
Cable: CMT-02HTH-0.8DA
ECG 1 and 2: lead I, lead II, lead III, aVR, aVL, aVF
5-electrode (chest) lead cable
2 waveforms
White
(RA)
Green
(RL)
Black
(LA)
Brown
(V)
Red
(LL)
Cable: CMT-03HTH-0.8DA
ECG 1: lead I, lead II, or lead III
ECG 2: V lead
Fukuda Denshi USA, Inc
17725-C NE 65th Street Redmond, WA 98052 USA
Toll Free
Free: (800) 365-6668 / Local
Local: (425) 881-7737 / Fax
Fax: (425) 869-2018
www.fukuda.com
The information contained in this document is subject to change without notice.
Nellcor®, OxiMax® and Durasensor® are registered trademarks of Covidien.
© 2011 Fukuda Denshi USA, Inc. All rights reserved.
Document No. USRB-0010-01