Convum

Transcription

Convum
Vacuum & Pressure
Sensors
Section C
C
Convum
175
Vacuum & Pressure Sensors
Index
176
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
Index
Technical Information
Pressure
Range
178 - 181
Output
Type
Maximum
IP
Rating
Hysteresis
Output Mode
Adjustment
Air,
Non-Corrosive
Gas
65
Air,
Non-Corrosive
Gas
65
Air,
Non-Corrosive
Gas
65
Air,
Non-Corrosive
Gas
Output
Setting
Display
Page
Number
Variable,
3 to
20% F.S.
Trim Pot
—
182 - 185
Variable,
100% F.S.
Push
Button
LED Display
186 - 191
(Red)
Variable,
100% F.S.
Push
Button
LED Display
192 - 197
(Red)
65
Variable,
100% F.S.
Push
Button
LED Display
(Red / Green) 198 - 203
Air,
Non-Corrosive
Gas
40
—
Trim Pot
—
40
Variable,
100% F.S.
Push
Button
Air,
Non-Corrosive
Gas
40
Fixed,
< 2% F.S.
Trim Pot
40
Variable,
100% F.S.
Push
Button
LED Display
222 - 229
(Red)
65
Variable,
100% F.S.
Push
Button
LED Display
230- 235
(Red)
65
—
—
Media
MPS-1
0 to 10 bar
0 to -1 bar
0 to 0,9 bar
(1) NPN / PNP
With Analog
MPS-2
0 to -1 bar
-1 to 5 bar
(2) NPN / PNP
MPS-3
0 to 10 bar
0 to -1 bar
0 to 1 bar
-1 to 5 bar
(2) NPN / PNP
Analog Option
0 to 10 bar
0 to -1 bar
-1 to 5 bar
(1) NPN / PNP
MPS-31
MPS-6
0 to 10 bar
0 to -1 bar
0 to 1 bar
(1) NPN / PNP
or (1) Analog
—
204 - 209
MPS-7
Remote Panel: Use
with MPS-5,6,8
71: (2) NPN/PNP
Analog Option
74: (1) NPN/PNP
LED Display
210 - 217
(Red)
MPS-8
0 to -1 bar
-1 to 5 bar
(1) NPN / PNP
or (1) Analog
0 to -1bar
-1 to 5 bar
(1) NPN / PNP
Air,
Non-Corrosive
Gas
0 to 10 bar
0 to -1 bar
-1 to 5 bar
(2) NPN / PNP
Analog Option
Fluid,
Non-Corrosive
to 316L or
630 SUS
0 to 10 bar
0 to -1 bar
Analog
—
218 - 221
MVS-201
MPS-3 Stainless
MPS-5 Stainless
Fluid,
Non-Corrosive
to 316L or
630 SUS
—
236 - 239
P5V-SV
-0,15 to -0,9 bar
—
Air,
Non-Corrosive
Gas
Accessories
—
20% of
preset value
—
—
240- 241
242 - 243
177
04.10
www.parker.com/euro_pneumatic
C
Technical Information
Solid State Sensors
Difference Between Switch Output
and Analog Output Type
Introduction
Electromechanical pressure sensors convert the applied
pressure to an electrical signal. When pressure is applied,
the diaphragm is deflected causing the diffused resistors to
change resistance (piezoelectric effect), which yields an
electrical signal proportional to the pressure change.
Applications for pressure switches are numerous and
important in today's high-tech manufacturing environment.
Switch Output
This is an NPN / PNP Open Collector transistor Output that
“sinks” or “sources” the signal when the pressure switch
point is achieved. The switch point is set by programming or
potentiometer trimmer adjustment.
0
Silicon Diaphragm
This type of sensor is used for air and non-corrosive gas
applications.
on
h
off
on
off
H
Sensor Module
-1 bar
Window Comparator
Window Comparator provides two switch points at different
pressures to activate the NPN / PNP open collector transistor
outputs.
Silicon Diaphragm
Base
0
Pressure
off
A
on
on
b
off
off
-1 bar
Stainless Steel Diaphragm
This type of sensor is used for liquids, non-corrosive to 316L
or 630 stainless steel.
Analog Output
An analog output provides an output voltage that is
proportional and linear to the pressure measured by the
sensor. This output signal provides continuous feedback to
the analog card of the PLC.
Semiconductor
Pressure Element
20
Output (mA)
Body
SUS 316L
4
Output (Volts)
Analog Output
Stainless Steel
Diaphragm
SUS 316L
or
SUS 630
5
1
0
Pressure
178
0
Pressure
Max. Rating
04.10
www.parker.com/euro_pneumatic
Technical Information
Difference Between NPN and PNP Output
NPN
PNP
NPN type open collector transistor outputs are solid state circuits that provide sinking output capabilities. When the transistor is on, the current for the load flows into the transistor.
This output “sinks” toward 0 VDC, 0 mA.
PNP type open collector transistor outputs are solid state circuits that provide sinking output capabilities. When the transistor is on, the current for the load flows out of the transistor.
This output “sources” toward 24 VDC, 125 mA.
NPN Output (With Analog Output)
PNP Output (With Analog Output)
D1
Load
ZD1
Tr2
(White) Out 2
Max. 125 mA
1K
(Pink) Analog
Option
ZD3
Load
Max. 125 mA
ZD2
+
–
DC
10,8 V to 30 V
DC
1 to 5 V
(Brown) +V
ZD1
ZD2
Tr1
Main Circuit
(Black) Out 1
Tr1
Main Circuit
D1
(Brown) +V
(Black) Out 1
(Pink) Analog
Or Tr
D1
Load
Load
Tr1
+
Main Circuit
Main Circuit
ZD1
DC
– 10,8 V to 30 V
Max. 125 mA
(White) Out 2
Tr2
Max. 125 mA
ZD2
DC
10,8 V to 30 V
C
Load
PNP Output (With Reset IN)
(Black) Out 1
Tr1
–
(Blue) O V
NPN Output (With Reset IN)
(Pink) Digital IN
Option
Load
DC
1 to 5 V
Option
1K
(Blue) O V
(Brown) +V
+
(White) Out 2
ZD3
D1
Max. 125 mA
Tr2
(Blue) O V
Tr2
ZD1
ZD2
Or Tr
(Brown) +V
Max. 125 mA
(Black) Out 1
(White) Out 2
Max. 125 mA
+
–
DC
10,8 V to 30 V
Load
(Pink) Digital IN
Option
(Blue) O V
Load
Reset Input Option
By sending a 5 VDC signal to the sensor, it is possible to automatically reset the sensor to ambient zero when small fluctuations in the system or atmosphere influence the beginning reference point.
Fluctuation
H
Negative
Pressure
Digital Set
H
OK
NG
IN
Negative OK
Pressure
OK
IN
IN
IN
Flashing display of AL is displayed when the
digital IN signal is entered.
179
04.10
www.parker.com/euro_pneumatic
Technical Information
Output Modes
Repeatability
Switch Point with Hysteresis Settings
The repeatability refers to the sensor’s ability to provide the
same output with consecutive applications of the same
pressure input.
Reading
Repeatability
This output mode provides one switch point (H) and a hysteresis pressure adjustment. When the switch point pressure is
achieved, the output (NPN / PNP) is activated if normally open
or deactivated if normally closed. Typically, this mode is used
for pressure confirmation. For positive pressure applications,
this operating mode does not provide any output or alarms beyond the switch point in the case of excessive pressures.
The hysteresis setting (h) is the difference in pressure below
the switch point pressure which controls the on / off status of
the output.
+
P1
Pressure
0
on
h
Repeatability is represented as a percentage of the full scale
value of the sensor. All Parker / Convum sensors are rated
± 0,2% F.S. P1 would be represented as 10 bar x 0,002 =
± 0,02 bar.
on
off
off
H
Accuracy
-1 bar
Window Comparator Setting
This output mode provides two switch points (A) and (b)
that control the output signals (NPN / PNP) between the two
pressures. This creates a “window” that the sensor can provide an output and is sometimes referred to as “high / low”
setting. The window comparator Mode provides an output or
alarm when pressures exceed the upper limit.
0
on
on
b
off
Display Resolution
The least possible unit increment shown on the display.
IP Ratings
IP40 - Protected against solid foreign objects of 0,04"
(1 mm) and greater.
Non-protected against the penetration of liquids.
IP65 - Dust tight.
Protected against water jets.
IP67 - Dust tight.
Protected against the effects of temporary
immersion water.
off
A
The PERCENTAGE difference between the true value and that
indicated by an instrument is the measure of the instrument’s
accuracy. It is expressed as a percentage of the full-scale
value of the reading according to the type of instrument.
off
-1 bar
Pressure Unit Table
Units
Units
Pa
bar
PSI
kgf/cm2
atm
mm H2O
in H2O
mm Hg
in Hg
Pa
1
10-5
0,145x10-3
1,0197x10-5
0,987x10-5
0,10197
0,402x10-2
0,750x10-2
0,295x10-3
bar
105
1
14,5038
1,01972
0,98692
10197,16
401,46
750,062
29,53
PSI
6894,76
0,06895
1
0,07031
0,6805
703,07
27,68
51,715
2,036
kgf/cm 2
98066,5
0,9807
14,2233
1
0,96784
10000
393,70
735,56
28,96
atm
1,013x10-5
1,01325
14,696
1,03323
1
10332
406,77
760
29,92
mm H2O
9,807
0,098x10-3
0,00142
0,0001
0,097x10-3
1
0,0394
0,07355
0,29x10-2
in H2 O
249,09
0,249x10-2
0,0361
0,00254
0,246x10-2
25,4
1
1,868
0,07355
mm Hg
133,322
0,00133
0,01934
0,00136
0,00132
13,5951
0,535
1
0,0394
in Hg
3386,4
0,03378
0,4912
0,0345
0,03353
345,32
13,589
25,4
1
180
04.10
www.parker.com/euro_pneumatic
Technical Information
Pressure Value Display Mode. Displays Pressure
for a specific time period and then updates for
next time period
Output 1
Output 2
Time Range for Pressure Value Display Mode
Output 3
Value Setting for Pressure Value Display Mode
Output 4
Display Peak Value over selected time range
Output Normally Closed (Passing)
Display Bottom Value over selected time range
Output Normally Open (Non-Passing)
Display Difference over selected time range
Pressure Units (Pascal).
Negative Units for Vacuum Sensors
Display Function Mode. On/Off
Pressure Units (Bar).
Negative Units for Vacuum Sensors
Display Function. Selects display types.
Pressure Units (in.Hg).
Negative Units for Vacuum Sensors
Display blinks pressure when Output 1 is Passing
Normal when Output 1 is Non-Passing
Pressure Units (in.Hg).
Negative Units for Vacuum Sensors
Display blinks pressure when Output 2 is Passing
Normal when Output 2 is Non-Passing
Pressure Units (kgf/cm ).
Negative Units for Vacuum Sensors
2
Display shows pressure when Output 1 is Passing
Display shows special screen when Non-Passing
Pressure Units (PSI)
Display shows pressure when Output 2 is Passing
Display shows special screen when Non-Passing
Easy Mode. Sensor will only allow
changes to set points
Select Switch Output setting for MPS-31
Off, or Energy Saving Display; reduces current
consumption of Sensor
Color Setting for MPS-31
On
MPS-4, Port Reference Selection
Hysteresis Mode. Select Hysteresis
Set Point and Hysteresis Range
MPS-4, Display change of B port to A port static
Windows Comparative Mode
Select High and Low Set Point
MPS-4, Display change of A port to B port static
Hysteresis Mode Set Point. Output 1
MPS-4, Display change of A port to
change of B port
Hysteresis Mode Set Point. Output 2
MPS-7, Pressure Range Selection Vacuum
Hysteresis Mode.
Hysteresis Range Output 1
MPS-7, Pressure Range Selection Low Pressure
Hysteresis Mode.
Hysteresis Range Output 2
MPS-7, Pressure Range Selection
Positive Pressure
Windows Comparative Mode
Low Set Point Output 1
MPS-7, Pressure Range Selection
Compound Pressure
Windows Comparative Mode
High Set Point Output 1
MPS-7, Energy Savings Mode, reduces
current consumption
Windows Comparative Mode
Low Set Point Output 2
MPS-7, Peak Surveillance
Windows Comparative Mode
High Set Point Output 2
Digital Input Sensors Only. Digital Input Mode for
remote Zero reset of sensors
Automatic Teach Mode. Automatically sets
Outputs 1 and 2 while cycling system. Output 1
set to Hysteresis Mode, Output 2 set to Window
Comparative Mode
Digital Input
Auto Surveillance Mode On/Off.
Set after Automatic Teach
Digital Channel
Auto Surveillance based on cycles times.
Provides output if Peak Value is not obtained in
a specified number of cycles. (1-100)
MPS-7 Scan Mode. Sensor scans and displays
each channel for 3 sec.
Locked. Sensor programs cannot be changed
Display Refresh Setting. Display updates from
0,1 to 1 sec. 0,3 sec factory set. Does not affect
Sensor Response Time
Output Response Time. Multiples the sensor
response time. Increases sensor response time.
(Anti-chatter Mode)
Unlocked. Sensor programs can be changed
Zero Reset
181
Sets Sensors reference point to current
atmospheric conditions
04.10
www.parker.com/euro_pneumatic
C
Vacuum & Pressure Sensors
MPS-1
Features
MPS-1
• Pressure Ranges:
Vacuum .................................... 0 to -1 bar
Positive Pressure ................... 0 to 10 bar
• Sensor Outputs
1 Normally Open NPN or PNP Open
Collector Transistor Output;
30 VDC, 125 mA
1 Analog 1 to 5 VDC
• Switch Output Adjusted with
Potentiometer 3-Turn Trimmer
• Switch Hysteresis Adjusted with
Potentiometer 3/4 Turn Trimmer
• Output Response Time Less Than
2,5 Milliseconds
Output
MPS-V1G-PC
PNP
0 to -1 bar
MPS-P1G-PC
PNP
0 to 10 bar
MPS-V1E-PC
PNP
0 to -1 bar
MPS-P1E-PC
PNP
0 to 10 bar
• IP65 Rated and CE Marked
Pressure Range
• Air and Non-Corrosive Gases
Switch Output
Output Modes
The MPS-1 Series Sensor has two outputs,
one open NPN or PNP switch output and one
analog output. The Hysteresis Range (h)
controls the output signal below the Switch
Point (H).
The Pressure Output Signal is a 3 turn trimmer
that sets the switch point of the output. The
hysteresis adjustment is a 3/4 turn trimmer to
control the output signal 3 to 20% below the
pressure output signal. The Analog Output is
a 1 to 5 VDC signal calibrated to the pressure
scale of the sensor.
0
on
h
off
on
off
H
-1 bar
Analog Output
Analog Output
Output (Volts)
Model Number
5
1
0
182
0
Pressure
Max. Rating
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-1
Model Number Index
MPS - V 1 G - P
Pressure Range
V 0 to -1 bar
P 0 to 10 bar
Port Size
G 1/8" BSPP / M5F
E Flange / M5F
C
Circuit
N NPN Sinking Output
P PNP Sourcing Output
Electrical Connector
C M8 4-Pin
C
MPS-L1G-PC
MPS-V1E-PC
Specifications
Media
Pressure Port
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Air and Non-Corrosive Gases
G: 1/8" BSPP, E: Flange Mount with M5 Female
V: 5 bar, P: 15 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
4-Pin, M8 Connector with Built-in LED
Power Supply
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
Analog Output
1 to 5 VDC ±0,04, Accuracy Linear 0,5% F.S.
Switch Output
N.O., Switch Output Mode with Hysteresis Adjustment
Output Circuit
Switch Output Setting H
Hysteresis Setting h
NPN (Sinking), PNP (Sourcing) Open Collector Transistor 30 VAC, 80 mA
3-Turn Trimmer
3/4-Turn Trimmer (3 to 20% of Switch Output Setting)
Response Time
< 2,5 ms
Repeatability
±1% F.S.
Thermal Error
General Protection
Current Consumption
Spike Protection
Dielectric Strength
Insulation Resistance
Vibration Resistance
Shock Resistance
Material
Mass
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP65 or IP40, EMC Rating : EN55011 Class B, EN50082-2
< 20 mA
400 VP, 1 µs
1000 VAC, 1 min.
> 100 Mohms at 500 VDC
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
100 G, XYZ
Housing: Polycarbonate, Pressure Port: Zinc Die-cast
30 g
183
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-1
Output Setting
!
Switch Output Setting
The MPS-1 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Potentiometer for the Switch Point Pressure and Hysteresis
Range is sensitive. Excessive force or exceeding the limits of
the trimmers may cause damage.
The Switch Point of the output signal is adjusted with a
3-turn potentiometer trimmer (S)
(S). To set the switch point pressure, rotate the trimmer clockwise to raise the switch pressure
and rotate the trimmer counter clockwise to lower the switch
pressure.
Cautions
Operating Environment
S
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
H
Hysteresis Setting
Installation
The Hysteresis setting is a 3/4 - turn potentiometer trimmer
with a range of 3% to 20% below the switch point (S)
(S). Rotate
the Hysteresis trimmer (H) clockwise to increase the Hysteresis range and rotate the trimmer counter clockwise to lower
the Hysteresis range (h)
(h). A separate pressure gauge is necessary to accurately adjust these values.
For best results, set the switch point (H) of the output signal
before adjusting the hysteresis range. For fine tuning the hysteresis range, re-adjust the switch point (S) of the output signal.
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using the metal mounting base.
• To achieve IP65 rating, connect the o-ring and barb to a
normal environment with a 2 mm I. D. tube and install screw
as shown.
S
H
Barb
Coupling
O-Ring
S
H
-INCLUDED-
Wiring Diagram
Screw
Internal Circuit
Pin #
1 Brown:24 VDC
2 White: Analog 1 to 5 VDC Output
3 Blue: 0 VDC
4 Black: NPN / PNP Open Collector Output
H
1
1
2
2
4
H
4
S
NPN (Sinking)
Sensor Male
Pin Out
4
3
3
S
3
PNP (Sourcing)
2
1
184
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-1
Dimensions
M5Fx5
G
M3Fx4
2 Places
LED
S
1/8" Male
M8, 4-Pin
M8
21,2
H
8
G1/8M
45
9
15,7
E
M3Fx5
4 Places
Flange
Mount
M4F
2 Places
M3Fx4
2 Places
LED
S
M5Fx5
M8, 4-Pin
19
13
8
21,2 24,7
M8
H
C
10
9
44
1,5
15,7
9
Accessories
44
8
Flange Bracket
for V1E Type
19
(Not included)
= ACCMPS-1E
Ø 4,5
4 Places
33
31
0,8
30
7,4
16
3,2
Cables
7,2
CB-M8-4P-2M
Ø5
Ø 9,7
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
22
5m
185
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-2
Features
MPS-2
• Pressure Ranges:
Vacuum .................................... 0 to -1 bar
Positive Pressure ................... 0 to 10 bar
• Sensor Outputs:
2 NPN or PNP Open Collector Transistor
Output , 30 VDC, 125 mA
• Switch Point and High-low Programming
• 4 Selectable Units of Measure
(mmHg, -bar, -kPa, inHg)
(kgf/cm2, PSI, bar, kPa)
• Output Response Time Less Than
2,0 Milliseconds
• IP65 Rated and CE Marked
Model Number
Output
MPS-V2G-PC
PNP
0 to -1 bar
MPS-P2G-PC
PNP
0 to 10 bar
• Air and Non-Corrosive Gases
Pressure Range
• Error Message
Switch Output
Output Modes
0
The MPS-2 Series Sensor has two independent NPN or PNP open collector output signals.
The Switch Output Mode has a switch point
programmed by the user at a specified pressure. The Hysteresis Range (h) adjustment
controls the output signal 0 to 100% below the
Switch Point (H).
The Window Comparator Mode provides two
Switchpoint Settings (A) and (b) that control
the output signals (NPN / PNP) between two
pressures. This is referred to as the “High /
Low” setting.
on
h
off
on
off
H
-1 bar
Window Comparator Output
0
off
A
on
on
b
off
off
-1 bar
186
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-2
Model Number Index
MPS - V 2 G - P
Pressure Range
V 0 to -1 bar
P 0 to 10 bar
Port Size
G 1/8" BSPP
M5 M5 Female*
Circuit
N NPN Sinking
Output
P PNP Sourcing
Output
* Din Rail Only
C
–
Din Rail
Blank Without
R*
With
Electrical Connector
C
M8 4-Pin
* M5 Port Size Only
C
MPS-V2G-PC
MPS-P2M5-PGR
Specifications
Pressure Range
Vacuum (V)
Units of Measure
Display Resolution
kPa:
0,1
Media
Air and Non-Corrosive Gases
Pressure Port
G: 1/8" BSPP, M5: M5 Female
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Display
Display Refresh
Positive (P)
MPa:
0,001
V: 5 bar, P: 15 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
C: 4-Pin, M8 Connector
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
3-Digit, 7-Segment LED
0,1 to 3,0 sec. (Factory set at 0,1)
Output Circuit
NPN (Sinking) or PNP (Sourcing) Output, Open Collector Transistor 30 VDC, 125 mA
Switch Output
2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator
Output Modes
Response Time
Repeatability
Thermal Error
General Protection
Insulation Resistance
Vibration Resistance
Shock Resistance
Material
Mass
Hysteresis or Window Comparator
< 2 ms, with Programmable Increments 32, 128, 1024 ms
± 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP65 or IP40, CE Rating, EMC-EN55011 Class B, EN 50082-2
> 100 Mohms at 500 VDC
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Housing: Polycarbonate, Pressure Port: Zinc Die-cast
45 g
187
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
Wiring Diagram
Pin #
1 Brown:24 VDC
2 White: NPN / PNP Open Collector Output
3 Blue: 0 VDC
4 Black: NPN / PNP Open Collector Output
MPS-2
Sensor Male
Pin Out
4
2
3
1
Internal Circuit
NPN
PNP
1
1
2
2
4
!
4
3
3
NPN Sinking
PNP Sourcing
Cautions
The MPS-2 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead to
V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install as shown using the metal mounting base.
• To achieve IP65 rating, connect the o-ring and barb as
shown to a normal environment with a 2 mm I. D. tube.
Ambient Air
Inlet Port
2
1
Barb
O-Ring Coupling
–INCLUDED–
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
2
1
Error Messages
Display
188
Description
Solutions
Err
Zero Reset Error
3% of F.S.
Reset Zero Below
Er1
System Error (Internal)
Contact Factory
Er2
Auto Teach Mode Error
Restart Function
CE1
Over current of Output 1
Load current exceeds
CE2
Over current of Output 2
maximum 125 mA.
FFF
–FF
Applied pressure exceeds
pressure range
Apply pressures with
the rating of the sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-2
Dimensions
G
1/8" Male
M8, 4-Pin
2 1
M5Fx0,8
44
M3Fx4 Vent Port
25
14
12,5
5,7
8
G1/8M
Din Rail
M5 Female
59
9
C
16
3,8
61
Grommet
2 1
M5Fx0,8
M3Fx4 Vent Port
25
14
12,5
5,7
10
16
88
189
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-2
See page 181 for Symbol Explanation
1 Hold
Press
2
2 1
4 Press
Press
1x
2 1
Output Set Open
or Closed Selecting
Units of Measure
Easy Mode
Activation
1x
2 1
2x
5 Press
Output 1 Setting
Hysteresis
Mode
3
3x
2 1
Press
Output Mode 1
Hysteresis or
Window
Comparator
Output 2 Setting
Hysteresis
Mode
4x
2 1
6
Press
Output Mode 2
Hysteresis or
Window
Comparator
5x
2 1
Automatic Teach Mode
& Auto Surveillance
Vacuum
Cycle
Window Comparator
Mode
Low
Window Comparator
Mode
Low
High
7 Press
High
6x
2 1
10 Hold
Press
8 Press
Display Refresh
Settings / Output
Response Time
Interval
11 Press
2 1
Unlock
7x
2 1
Hold
Press
2 1
Lock
Release
Cycle
1x
Display Peak Value
Bottom Value or
Their Difference
Press
2 1
1x
2 1
9 Press
8x
2 1
12 Press
Special Display
Features
for 3 Seconds
Zero
Reset
2 1
2 1
Bottom
Value
Peak
Value
190
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-2
Accessories
Cables
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
C
32
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
Din Rail
MPS-ACCK4
13
88
10
191
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Features
MPS-3
• Pressure Ranges:
Vacuum ................................... 0 to -1 bar
Positive Pressure .................. 0 to 10 bar
• Sensor Outputs:
2 NPN or PNP Open Collector
Transistor Output, 30 VDC, 125 mA
Optional Analog 1 to 5 VDC
• Switch Point and High-low Programming
• 4 Selectable Units of Measure
(mmHg, -bar, -kPa, inHg)
(kgf/cm2, PSI, bar, kPa)
• Output Response Time Less Than 2,0
Milliseconds
• IP65 Rated and CE Marked
Model Number
Output
MPS-V3G-PC
PNP
Pressure Range
0 to -1 bar
MPS-V3G-PG
PNP
0 to -1 bar
MPS-P3G-PC
PNP
0 to 10 bar
MPS-P3G-PG
PNP
0 to 10 bar
Output Modes
The MPS-3 Series Sensor has two independent NPN or PNP open collector output signals. An analog output is optional. The Switch
Output Mode has a switch point programmed
by the user at a specific pressure. The Hysteresis Range (h) adjustment controls the output
signal 0 to 100% below the Switch Point (H).
The Window Comparator Mode provides two
Switchpoint Settings (A) and (b) that control
the output signals (NPN / PNP) between two
pressures. This is referred to as the “High /
Low” setting.
The optional Analog Output Signal is calibrated to the pressure scale of the sensor.
• Air and Non-Corrosive Gases
• Error Message
Switch Output
0
on
h
off
on
off
H
-1 bar
Window Comparator Output
0
off
A
on
on
b
off
off
-1 bar
192
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Model Number Index
MPS - V
Pressure Range
V 0 to -1 bar
P 0 to 10 bar
Port Size
G 1/8" BSPP
3
G - P
C
Circuit
N NPN Sinking Output
P PNP Sourcing Output
Electrical Connector
C
4-Pin, M8
G
Grommet (2m)
C
MPS-V3G-PC
MPS-V3G-PG
Specifications
Pressure Range
Units of Measure
Display Resolution
Media
Pressure Port
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Display
Display Refresh
Output Circuit
Switch Outputs
Output Modes
Output Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Vibration Resistance
Shock Resistance
Material
Mass
Vacuum (V)
Positive (P)
kPa:
MPa:
0,1
0,001
Air and Non-Corrosive Gases
G: 1/8" BSPP Female
V: 10 bar, P: 15 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
C: 4-Pin, M8 Connector, G: Grommet Open Lead
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
3-Digit, 7-Segment LED
0,1 to 3,0 sec. (Factory set at 0,1)
NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA
2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator
Hysteresis or Window Comparator
< 2 ms with Programmable Increment 32, 128, 1024 ms (XS2H2-32, 256, 512 ms)
± 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP65 or IP 40, CE Rating, EMC-EN55011 Class B, EN 50082-2
< 55 mA
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Housing: Polycarbonate, Pressure Port: Zinc Die-cast
45 g
193
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Open Collector Wiring
Pin #
1 Brown:24 VDC
2 White: NPN / PNP Open Collector Output
3 Blue: 0 VDC
4 Black: NPN / PNP Open Collector Output
Sensor Male
Pin Out
4
3
!
2
1
Cautions
The MPS-3 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install as shown using the metal mounting bracket.
• To achieve IP65 rating, connect the o-ring and barb as
shown to a normal environment with a 2 mm I. D. tube.
Pipe Plug
Ambient Air
Inlet Port
Barb
O-Ring Coupling
–INCLUDED–
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
Error Messages
Display
194
Description
Solutions
Err
Zero Reset Error
3% of F.S.
Reset Zero Below
Er1
System Error (Internal)
Contact Factory
Er2
Auto Teach Mode Error
Restart Function
CE1
Over current of Output 1
Load current exceeds
CE2
Over current of Output 2
maximum 125 mA.
FFF
–FF
Applied pressure exceeds
pressure range
Apply pressures with
the rating of the sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Dimensions
G
1/8" Female
4,5
27
30
20
8,5
13
30
1
20
2
1
2
6,7
12,2
1/8" BSPP
4
M3
Venting
Port
M8
Grommet Lead
C
4-Pin Connector
MPS-ACCK1
Mounting
Brackets
(Included)
14
14
7
5,5
25
27
28
20
20
20
20
30
43
Ø 4,5
Ø 4,5
13
6
35
22
195
5,5
13
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
See page 181 for Symbol Explanation
1 Hold
Press
2
1x
Press
2x
4
Press
1x
3
Press
4x
Output Mode 1
Hysteresis or
Window
Comparator
Output Set Open
or Closed Selecting
Units of Measure
Easy Mode
Activation
5
Press
Output Mode 2
Hysteresis or
Window
Comparator
3x
6
Output 1
Switch Point
Setting
Output 2
Switch Point
Setting
Hysteresis
Mode
Hysteresis
Mode
Press
5x
Automatic Teach Mode
& Auto Surveillance
Vacuum
Cycle
Window Comparator Mode
Low
High
7
Press
High
6x
8
Press
7x
Display Refresh
Settings / Output
Response Time
Interval
10 Hold
Press
Release
Cycle
Window Comparator Mode
Low
1x
Lock
Hold
Press
9
Press
Display Peak Value
Bottom Value or
Their Difference
1x
Unlock
11
Press
1x
Press
1x
8x
Special Display
Features
12
Press
for 3 Seconds
Zero
Reset
Bottom
Value
Peak
Value
196
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Accessories
Cables
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
C
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
MPS-ACCH7
Panel Mounting
Bracket
43,8
40
40
Knockout
33,4
1
36
(+0.5, -0.2)
2
36
(+0.5, -0.2)
197
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
Features
MPS-31
Red
MPS-31
Green Display
• Pressure Ranges:
Vacuum ................................... 0 to -1 bar
Positive Pressure .................. 0 to 10 bar
• Sensor Output:
1 NPN or PNP Open Collector
Transistor Output , 30 VDC, 125 mA
• Switch Point and High-low Programming
• 4 Selectable Units of Measure
(mmHg, -bar, -kPa, inHg)
(kgf/cm2, PSI, bar, kPa)
• Output Response Time Less Than 2,0
Milliseconds
• IP65 Rated and CE Marked
Model Number
Output
Pressure Range
MPS-V31G-PC
PNP
0 to -1 bar
MPS-V31G-PG
PNP
0 to -1 bar
MPS-P31G-PC
PNP
0 to 10 bar
MPS-P31G-PG
PNP
0 to 10 bar
Output Modes
The MPS-31 Series Sensor has one
independent NPN or PNP open collector
output signal. The Switch Output Mode has a
switch point programmed by the user at a
specific pressure. The Hysteresis Range (h)
adjustment controls the output signal 0 to
100% below the Switch Point (H).
The Window Comparator Mode provides two
Switchpoint Settings (A) and (b) that control
the output signals (NPN / PNP) between two
pressures. This is referred to as the “High /
Low” setting.
• Air and Non-Corrosive Gases
• Error Message
Switch Output
0
on
h
off
on
off
H
-1 bar
Window Comparator Output
0
off
A
on
on
b
off
off
-1 bar
198
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-31
Model Number Index
Bold Items Are Standard
Pressure Range
V 0 to -1 bar
P 0 to 10 bar
R -1 to 5 bar
MPS -
Port Size
G 1/8" BSPP
V 31
G - P
C
Circuit
N NPN Sinking Output
P PNP Sourcing Output
Electrical Connector
C 4-Pin, M8
G Grommet (2 m)
C
MPS-V31G-PG
Mounting Bracket MPS-ACCK1 Included with Sensors.
MPS-V31G-PC
Specifications
Pressure Range
Units of Measure
Display Resolution
Media
Pressure Port
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Display
Display Refresh
Vacuum (V)
kPa:
Positive (P)
0,1
MPa:
Compound (R)
0,001
kPa:
1
Air and Non-Corrosive Gases
G: 1/8" BSPP
V: 10 bar, P: 15 bar, R: 10 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
C: 4-Pin, M8 Connector, G: Grommet Open Lead
10,8 to 26,4 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
3-Digit, 7-Segment LED
0,1 to 3,0 sec. (Factory set at 0,1)
Output Circuit
NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA
Switch Output
Output Signal, NPN or PNP, Normally Open or Closed, LED Indicator
Output Modes
Output Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Vibration Resistance
Shock Resistance
Material
Mass
Hysteresis or Window Comparator
< 2 ms, 32, 256, 512 ms Programmable (Factory set 2 ms)
± 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP65 or IP40, CE Rating, EMC-EN55011 Class B, EN 50082-2
< 70 mA
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Housing: Polycarbonate, Pressure Port: Zinc Die-cast
48 g
199
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
Open Collector Wiring
Sensor Male
Pin Out
Pin #
1
2
3
MPS-31
Brown: 24 VDC
Black: NPN/PNP Output 1
Blue: 0 VDC
4
2
3
1
Internal Circuit
(Brown) +V
D1
(Black) Out 1
Tr1
ZD1
(Blue) OV
LOAD
Max. 125mA
Main Circuit
Main Circuit
D1
+DC
- 10.8V to 30V
Tr1
(Brown) +V
ZD1 (Black) Out 1 (N.O.)
LOAD
Max. 125mA
+DC
- 10.8V to 30V
(Blue) OV
NPN
!
Cautions
The MPS-31 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
PNP
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install as shown using the metal mounting bracket.
• To achieve IP65 rating, connect the o-ring and barb to a
normal environment with a 2 mm I. D. tube.
Pipe Plug
Ambient Air
Inlet Port
Barb
O-Ring Coupling
–INCLUDED–
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
Error Messages
Display
Err
200
Description
Solutions
Zero Reset Error
3% of F.S.
Reset Zero Below
Er1
System Error (Internal)
Contact Factory
CE1
Over current of Output 1
Load current exceeds
FFF
–FF
Applied pressure exceeds
pressure range
Apply pressures with
the rating of the sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-31
Dimensions
G
1/8" Female
27
4,5
30
20
8,5
13
20
30
6,7
12,2
4
1/8" BSPP
Grommet Lead
C
M3
Venting
Port
M8
4-Pin Connector
MPS-ACCK1
Mounting
Brackets
(Included)
14
14
7
5,5
25
27
28
20
20
20
20
30
43
Ø 4,5
Ø 4,5
13
6
35
22
201
5,5
13
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-31
See page 181 for Symbol Explanation
1 Press
for 3 Seconds
Begin Programming
Operating
Output Mode
Or Press
Select Units
of Measure
Output Normally
Open or Closed
1x to Proceed
Wait 3 Seconds
Or Press
1x to Proceed
Wait 3 Seconds
Display
Refresh
Or Press
1x to Proceed
Wait 3 Seconds
Or Press
1x to Proceed
Wait 3 Seconds
Output Response
Selection
Display Color Choices
Red and / or Green,
Energy Save
Or Press
Or Press
1x to Proceed
Wait 3 Seconds
1x to Return
Output
On
Off
Red
Green
Wait 3 Seconds
Green Red
Red
Red
Green Green
2
Press
1x
3
Switch Output
Setting and
Low Setting
4
Hold
Press
Hold
Press
1x
1x
Will Display for 1 Second
Hysteresis Mode
Low
1x
Hysteresis
Setting and
High Setting
Will Display for 1 Second
Window Comparator Mode
Press
Hysteresis Mode
Window Comparator Mode
Lock
5
Unlock
Zero
Reset
High
Wait 5 Seconds
Wait 5 Seconds
202
Press
for3 Sec.
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-31
Accessories
Cables
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
C
32
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
MPS-ACCH7
Panel Mounting
Bracket
43,8
40
40
Knockout
33,4
36
(+0,5, -0,2)
36
(+0,5, -0,2)
203
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
Features
Model Number
Output
Pressure Range
MPS-V6G-PC
PNP
0 to -1 bar
MPS-V6G-AG
Analog
0 to -1 bar
MPS-V6G-AGE
Analog
0 to -1 bar
MPS-P6G-PC
PNP
0 to 10 bar
MPS-P6G-AG
Analog
0 to 10 bar
MPS-P6G-AGE
Analog
0 to 10 bar
Output Modes
The MPS-6 Series Sensor is compact and
lightweight with NPN or PNP open connector
switch output or analog output capabilities.
The sensor can be used as a stand alone unit
or in combination with the MPS-7 series display. The MPS-6 Switch Output unit provides
one open and closed output for the same
switch point. The MPS-6 Analog Output unit
provides analog output 1 to 5 VDC. Analog
output is required for use with the MPS-7 display.
• Pressure Ranges:
Vacuum ................................... 0 to -1 bar
Positive Pressure .................. 0 to 10 bar
• Sensor Outputs:
1 Open and 1 Closed NPN or PNP Open
Collector Transistor Output
30 VDC, 125 mA
1 Analog Output 1 to 5 VDC
• Switch Point 2/3 Trimmer
• Fixed Hysteresis 2%
• Output Response Time Less Than 1
Millisecond
• Analog Output Type Compatible with
MPS-7 Display
• IP40 Rated and CE Marked
• Air and Non-Corrosive Gases
Switch Output
0
on
S
Fixed
2%
off
on
off
-1 bar
Analog Output
Output (Volts)
MPS-6
5
1
0
204
0
Pressure
Max. Rating
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
Model Number Index
MPS - V
Pressure Range
V 0 to -1 bar
P 0 to 10 bar
Port Size
G 1/8" BSPP &
M5 Female
T 6 mm Tube Stud
6
G - P
C
Output Circuit
N NPN Output
P PNP Output
A Analog (1 to 5 VDC)*
Electrical Connector
C 4-Pin, M8
G Grommet (2 m)
GE 2 m Grommet Clip Conn.*
* With Grommet GE Only
* Use with MPS-7 Series Display,
with Analog Only
C
MPS-P6G-PC
MPS-P6G-AG
MPS-V6T-PG
MPS-P6G-AGE
Specifications
Media Air and Non-Corrosives Gases
Pressure Port G: 1/8" BSPP Male, T: 6 mm Tube Stud
Proof Pressure V: 5 bar, P: 15 bar
Operating Temperature 0 to 50 °C
Storage Temperature -10 to 60 °C
Humidity 35 to 85% RH
Electrical Connection C: 4-Pin, M8 Connector G: Grommet Lead GE: Clip Type for use with MPS-7 Display
Power Supply 10,8 to 30 VDC, Ripple Vp-p 10% max., Reverse Voltage Protection
Switch Output 1 Output Signal Open and Closed, NPN or PNP, 30 VDC, 125 mA
Linear Output Analog Output 1 to 5 VDC
Switch Point Setting 2/3 Turn Trimmer
Hysteresis Setting < 2% of F.S.
Output Response Time <1 ms
Repeatability <0,2% F.S.
Thermal Error 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
General Protection IP40, CE Rating EN55011 Class B, EN50082-2
Current Consumption < 20 mA
Spike Protection 400 VP, 1 µs, Surge Protection
Dielectric Strength 1000 VAC, 1 min.
Insulation Resistance > 100 Mohm at 500 VDC
Vibration Resistance 10 to 55 Hz, 0,75 mm Amplitude, XYZ, 2 hrs.
Shock Resistance 100 G, XYZ
Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast
Mass T Port: 7 g, N, R, G Port: 25 g
205
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
Open Collector Wiring
Analog Wiring
Pin #
1
2
3
4
Pin #
1
2
3
4
24 VDC
NPN / PNP Open Collector Output N. C.
0 VDC
NPN / PNP Open Collector Output N. O.
4
Sensor Male
Pin Out
Brown:
White:
Blue:
Black:
24 VDC
LED In 5 VDC
0 VDC
Analog 1 to 5 VDC
2
D1
3
Main Circuit
Brown:
White:
Blue:
Black:
1
Tr1
(Brown) +V
ZD1 (Black) Out 1 (N.O.)
Tr2
ZD2
(White) Out 2 (N.C.)
LOAD
Max. 125mA
+DC
– 10.8V to 30V
LOAD
Max. 125mA
(Blue) OV
Internal Circuit
NPN Open Collector
LED
D1
Main Circuit
Main Circuit
(Brown) +V
(White) Input for LED lighting (5VDC)
(Black) Analog 1 5V Output
+DC
- 10.8V to 30V
Tr1
(Brown) +V
ZD1 (Black) Out 1 (N.O.)
Tr2
ZD2
(White) Out 2 (N.C.)
LOAD
Max. 125mA
+DC
– 10.8V to 30V
LOAD
Max. 125mA
(Blue) OV
(Blue) OV
Analog
! Cautions
The MPS-6 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
PNP Open Collector
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using the metal mounting bracket.
Trimmer Adjustment
Rotate the potentiometer trimmer to increase or decrease
pressure switch point output. Excessive force or exceeding
the limits of the trimmers may cause damage.
Switch Point
Trimmer
–
206
+
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
Dimensions
G
1/8" Male,
M5 Female,
Grommet
16
Switch Point Trimmer
Output LED
26,3
1/8" BSPP
Output
LED
2m
20
or
M5–6
T6
Tube Stud,
Grommet
10
34,1
16
19,8
C
2m
20
6 mm Tube
10
G
1/8" Male,
M5 Female,
M8, 4-Pin
16
26,3
1/8" BSPP
Switch Point Trimmer
Output LED
Output
LED
20
or
T6
M5–6
Tube Stud,
M8, 4-Pin
15
34,1
16
Switch Point Trimmer
Output LED
19,8
20
6 mm Tube
15
G or T6
Grommet
Clip Connector
16
1/8" BSPP
26,3
AMP 5-Pin Connector
171822-5
20
M5–6
2m
207
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
Accessories
Cables
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
CB-M8-4P-5M-90
Ø 9,7
Ø 9,7
19
10,7
Ø5
5m
22
208
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-6
C
209
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
Features
MPS-7
• One Display with Output Programming
Capability for MPS-5, 6, or 8 Analog
Sensors
• Displays Pressure and Converts Analog
Signal from Remote Sensor to NPN or
PNP Open Collector Transistor Output,
30 VDC, 125 mA
• Compatible with 1 to 4 Remote Sensors
• MPS-71 Response Time Less Than
2,0 Milliseconds
• MPS-74 Response Time Less Than
5 Milliseconds
• IP40 Rated and CE Marked
Model Number
Output
MPS-71E-NC
NPN
MPS-71E-PC
PNP
MPS-71E-NG
NPN
MPS-71E-PG
PNP
MPS-74E-NG
NPN
MPS-74E-PG
PNP
MPS-71E-PG Control with Remote MPS-P6G-AGE Shown
Output Modes
The MPS-7 is a central display and control for
remote MPS-5, 6, 8 analog sensors. Each remote sensor supplies an analog signal to a
specific channel on the MPS-7 which is converted to an open connector output “NPN /
PNP”.
The Switch Output Mode has a switch point
programmed by the user at a specified pressure. The Hysteresis Range (h) adjustment
controls the output signal 0 to 100% below the
Switch Point (H).
The Window Comparator Mode provides two
Switchpoint Settings (A) and (b) that control
the output signals (NPN / PNP) between two
pressures. This is referred to as the “High /
Low” setting.
Switch Output
0
on
h
off
on
off
H
-1 bar
Window Comparator Output
0
off
A
on
on
b
off
off
-1 bar
210
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
Model Number Index
MPS - 7 1 E - N
Number of Remote
Sensors
1 1 Sensor
4 4 Sensors
C
Circuit
N NPN Output Sinking
P PNP Output Sourcing
Electrical Connector
C* 4-Pin, M8
G Grommet (2 m)
* Available on MPS-71 only.
C
MPS-74E-NG
MPS-71E-PG
Mounting Bracket Included with Sensors.
Specifications
Remote Pressure Range
Units of Measure
Display Resolution
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Vacuum (V)
Positive (P)
kPa:
MPa:
0,1
0,001
See Remote Sensor Specifications
0 to 50 °C
-10 to 60 °C
35 to 85% RH
G: Grommet Open Lead, C: M8 Connector
Power Supply
10,8 to 30 VDC, Ripple (P-P) 10% Max., Reverse Voltage Protection
Display
MPS-71: 3-Digit, 7-Segment LED, MPS-74: 4-Digit, 7-Segment LED
Display Refresh
Circuit
74 - 1 Switch Output
71 - 2 Switch Outputs
Linear Output Mode (71 Series)
Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Vibration Resistance
Shock Resistance
Material
Mass
MPS-71: 0,1 to 3,0 sec. (Factory set at 0,1), MPS-74: 0,2 Fixed
NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA
Output Signals, NPN or PNP, LED Indicator
Optional Output - Analog 1-5VDC, ± 0,2% Linear Accuracy, 0,5% F.S
MPS-71 <2 ms, MPS-74 <5 ms
± 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP40
MPS-71 <45 mA, MPS-74 <75 mA
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Body: Polycarbonate
MPS-71: .25 g, MPS-74: 28 g
211
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
MPS-71 Open Collector
Wiring
MPS-74 Open Collector
Wiring
Pin #
Grommet Lead Only
1
2
3
4
Brown:
Black:
Blue:
White:
24 VDC
NPN / PNP Open Collector
0 VDC
NPN / PNP Open Collector
Sensor Male
Pin Out
4
Brown:
Black:
Blue:
White:
Pink:
Orange:
24 VDC
NPN / PNP
0 VDC
NPN / PNP
NPN / PNP
NPN / PNP
Open Collector
Open Collector
Open Collector
Open Collector
2
3
1
Internal Circuit
(Brown) +V
Main Circuit
(Black) Out 1
(White) Out 2
(Pink) Out 3
(74E)
(Orange) Out 4
(74E)
(Blue) O V
MPS-71 & MPS-74 NPN / PNP Open Collector
!
Cautions
The MPS-7 Central Display is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Installation
• Avoid short-circuiting the MPS-7 Series. Connect the brown
lead to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using Panel Mount Bracket or Back Mount Brackets.
Error Messages
Display
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the MPS-7 Se
ries and set the ripple to Vp-p10% or less. Avoid excessive
voltage. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
212
Description
Solutions
Err
Zero Reset Error
Reset Zero
PErr
Peak Value Error
Source
Check Vacuum
Contact Factory
Er1
System Error (Internal)
CE1
Over current of Output 1
CE2
Over current of Output 2
CE3
Over current of Output 3 (MPS-74) maximum 125 mA.
CE4
Over current of Output 4 (MPS-74)
FFF
–FF
Applied pressure exceeds
pressure range
Load current exceeds
Apply pressures with
the rating of the
sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
Dimensions
30
MPS-71
2- M3
29
5
20
16,5
30
5
1
4
3
2
1
2
AMP EI 5-Pin Connector
171826-5
MPS-ACCK1
14
Mounting
Bracket
(Included)
14
7
5,5
25
27
20
C
28
Ø 4,5
Ø 4,5
20
20
20
30
43
13
6
5,5
22
35
13
MPS-74
40
25
AMP EI 5-Pin Connector
171825-5
10,5
CH-2
5
4
3
2
CH-1
1
5
1
5
CH-4
5
40
4
3
2
4
3
2
CH-2
1
5
1
5
CH-3
4
3
2
4
3
2
CH-1
1
5
1
5
CH-4
4
3
2
4
3
2
1
CH-3
4
3
2
1
1 2 3 4
Reset IN
5
2- M3
5
4
3
2
1
5
2- M3
30
30
30
MPS-ACCK3
Mounting
Bracket
Ø 3,5
30
Ø 4,5
(Included)
Ø 4,5
7
5,5
6
25
30
Ø 3,5
5,5
20
26
20
37
38
22
213
14,6
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
See page 181 for Symbol Explanation
2 Press
1 Hold
Press
2x
3
Output Set Open
or Closed
Easy Mode
Activation
4
Press
Press
4x
Output Mode 1
Hysteresis or
Window
Comparator
1x
1x
5
Press
Output Mode 2
Hysteresis or
Window
Comparator
3x
Output 1
Switch Point
Setting
6 Press
5x
Output 2
Switch Point
Setting
Hysteresis
Mode
Automatic Teach Mode
& Auto Surveillance
Hysteresis
Mode
Vacuum
Cycle
Window Comparator Mode
Low
High
7
Press
High
6x
8
Press
7x
Display Refresh
Settings / Output
Response Time
Interval
10 Press
9x
Low
Positive
Pressure Pressure
9
Press
8x
Display Peak Value
Bottom Value or
Their Difference
11 Hold
Press
Select
Units of
Measure
Select
Pressure
Vacuum
Release
Cycle
Window Comparator Mode
Low
1x
Lock
Hold
Press
12 Press
Special Display
Features
1x
Press
1x
13 Press
3 Sec
1x
Unlock
Peak
Value
Bottom
Value
Zero Reset
Compound
Pressure
214
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
1
Hold
Press
MPS-7
2
1x
Press
1x
Output Selection
Normally Open / Normally Closed
1 2 3 4
1 2 3 4
Select Output Mode
Hysteresis or Window Comparator
Output Setting
Peak Surveillance
(Repeat Procedure for Each Channel)
Window
Hysteresis Comparator
Mode
Mode
C
3
Press
4
2x
Press
3x
Select Remote Pressure
Select Unit of Measure
Save Energy Mode
Digital IN Mode
1 2 3 4
1 2 3 4
Vacuum
Low
Pressure
Standard
Pressure
Compound
Pressure
5 Press and Hold 3 Seconds
Scan Mode
1 2 3 4
6
Hold
Press
1x
1 2 3 4
1 2 3 4
Lock
Hold
Press
1x
1 2 3 4
Unlock
3 Second
Intervals
215
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
Accessories
Cables (Applicable to MPS-71E Display Units Only)
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
216
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-7
Accessories
MPS-ACCH4
Panel Mounting
Bracket for
MPS-71
43,8
40
40
Knockout
33,4
1
36
(+0.5, -0.2)
2
C
36
(+0.5, -0.2)
MPS-ACCH5
Panel Mounting
Bracket for
MPS-74
53,8
50
50
Knockout
1 2 3 4
46
(+0,5, -0,2)
46
(+0,5, -0,2)
217
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-8
Features
MPS-8
• Pressure Ranges:
Vacuum ................................... 0 to -1 bar
• Sensor Outputs:
1 NPN / PNP Open Collector Transistor
Output 30 VDC, 125 mA
1 Analog Output 1 to 5 VDC
• Switch Point 2/3 Trimmer Adjustment
• Fixed Hysteresis 2%
• 10 mm Wide
• Compatible with MPS-7 Display
• IP40 and CE Marked
• Air and Non-Corrosive Gases
Model Number
Output
MPS-V8A-PG
PNP
Pressure Range
0 to -1 bar
MPS-V8U-AG
Analog
0 to -1 bar
MPS-V8U-AGE
Analog
0 to -1 bar
Output Mode
Switch Output
The MPS-8 Sensor is 10 mm wide with an
NPN / PNP open collector switch output or an
analog output. The MPS-8 can be used in
combination with the MPS-7 series display or
as a stand alone unit. Analog output is required for use with the MPS-7 display.
0
on
S
Fixed
2%
off
on
off
-1 bar
Output (Volts)
Analog Output
5
1
0
218
0
Pressure
Max. Rating
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-8
Model Number Index
MPS - V
Pressure Range
V 0 to -1 bar
A
B
C
U
T
8
Port Size
M5 Through Female
M5 Through Female (With Mtg.)
M5 Bottom Female
M5 Bottom Swivel Male
4 mm Tube Stud
A - A
G
Output Circuit
A Analog (1-5VDC)
N NPN Sinking
Output
P PNP Sourcing
Output
Connector / Cable
G Grommet (2 m)
GE 2 m Grommet Clip Conn.*
* Use with MPS-7 Series Display,
with Analog Only
C
Specifications
Media
Pressure Port
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Switch Output
Linear Output
Switch Point Setting
Hysteresis
Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Spike Protection
Dielectric Strength
Insulation Resistance
Vibration Resistance
Shock Resistance
Material
Mass
Air and Non-Corrosive Gases
M5 Female, M5 Male Swivel, 4 mm Tube Stud
V: 5 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
G: Grommet Open Lead; GE: Clip Type for use with MPS-7 Series
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
1 Output, Normally Open, NPN or PNP Open Collector Transistor, 30 VDC, 125 mA
Analog Output 1 to 5 VDC
2/3 Trimmer
< 2% of F.S. Fixed
<1 ms
< 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP40, EMC rating : EN55011 Class B, EN50082-2
< 20 mA
Vp-p 400 v, 0,5 ms Surge Protection
1000 VAC, 1 min.
> 100 Mohms at 500 VDC
10 to 55 Hz, 1,5 mm amplitude, XYZ, 2 hrs.
100 G, XYZ
Body: Polycarbonate; Pressure Port: Anodized Aluminum
4g
219
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-8
Open Collector Wiring
Analog Wiring
Grommet Lead Only
Brown: 24 VDC
Blue:
0 VDC
Black: NPN / PNP Open Collector
Grommet Lead Only
Brown: 24 VDC
Blue:
0 VDC
Black: Analog 1 to 5 VDC
Internal Circuit
(Brown) +V
D1
(Black) Out 1
Tr1
ZD1
(Blue) OV
LOAD
Max. 125 mA
Main Circuit
Main Circuit
D1
+DC
- 10,8 V to 30 V
Tr1
(Brown) +V
ZD1 (Black) Out 1 (N.O.)
LOAD
Max. 125 mA
(Blue) O V
+DC
- 10,8 V to 30 V
PNP Open Collector
NPN Open Collector
Main Circuit
(Brown) +V
(Black) Analog 1 to 5 V Output
+DC
- 10,8 V to 30 V
(Blue) O V
Analog
! Cautions
The MPS-8 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using the metal mounting base.
Operations
• Dedicate a power supply of 10.8 to 30VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
220
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-8
Dimensions
MPS-8A
M5 Female,
Grommet
16
M5-6
M5-6
10
MPS-8B
M5 Female,
Grommet
20
4,75
M5-6
21
M5-6
10
3
Ø 3,5
2-Places
10
20
MPS-8C
M5 Female,
Grommet
16
C
4,75
4
Ø 3,2
2-Places
14
10
20
4,75
M5-6
MPS-8U
M5 Male Swivel,
Grommet
10,5
20,9
4
Swivel Joint for
Manifold Mount
4,75
20
M5
Connector
(AMP) 170204-15
8
Housing
(AMP) 171822-5
Shield
Grommet Clip Connector
(Available for All Models)
2m
221
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Features
MVS-201
• Pressure Range:
Compound Pressure ................. -1 to 5 bar
• Time Controlled Sensor
• Intelligent Simple 4-wire System
• Eliminate I/O for Release Valve
• 2 Functions with One Rung of Code
• Automatic Timer (0-9,9 sec.) Function by
Sensor Control Driver for Vacuum
Generating and Release Valves
• Peak Value Preventative Maintenance
Confirmation
• Response Time Less Than 2 Milliseconds
• CE Rated
The MVS-201 is a winning combination with the MC2,
CVR-2, and CVK vacuum generators. The MVS-201
automatically provides an output signal for the blow-off
function without the need of an additional output from
the PLC. Begin the vacuum cycle with an input signal
from the PLC to the “201” sensor. The “201” sensor
has one output NPN or PNP for vacuum confirmation
and a control output that interfaces directly with the
blow-off release pilot valve. With programmable time
control features and a special chip driver, the sensor
automatically activates the blow-off release when the
vacuum signal from the PLC is discontinued. This
eliminates, THE PREVIOUSLY REQUIRED, PLC
output to activate the blow-off release This new
technology eliminates PLC output requirements by
50% and reduces installation to a simple 4 wire
system by wiring the sensor only. There are 3 modes
of operation for various applications. The output
response time of the sensor is less than 2,5 msec.
Peak limit prevention maintenance feature is
automatically recorded internally.
Basic PLC System
P
L
C
I
N
O
U
T
-+
PLC System with 201 Sensor
Vacuum Pilot
Blow-Off Pilot
P
L
C
I
N
O
U
T
Sensor
Sensor Output 1
Sensor Output 2
-+
Vacuum Part Present Output
(V)
(V)
(B)
Output Modes
Switch Output
0
The MVS-201 Series Sensor has one
independent NPN or PNP open collector
output signal. The Switch Output Mode has a
switch point programmed by the user at a
specific pressure. The Hysteresis Range (h)
adjustment controls the output signal 0 to
100% below the Switch Point (H).
on
h
off
on
off
H
-1 bar
222
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Model Number
MVS - 201 - PCP
Specifications
Pressure Range
Units of Measure
Display Resolution
Media
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Display
Resolution & Units of Measure
Display Frequency
Circuit
Digital Output
Mode
Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Spike Protection
Dielectric Strength
Insulation Resistance
Vibration Resistance
Shock Resistance
Material
Mass
Compound (R)
kPa:
1
Non-Lubricated Air and Non-Corrosive Gases
6 bar
0 to 50 °C
C
-10 to 60 °C
35 to 85% RH
C: 4-Pin, M8 Connector
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
3-Digit, 7-Segment LED
kPa: 1, bar: 0,01, kgf/cm2: 0,01, PSI: 0,1
5 Hz
NPN (Sinking), PNP (Sourcing) Open Collector Transistor
Individually Selectable N.O. or N.C., max 125 mA, 30 V, with Overcurrent Protection
OP1, OP2, OP3 Hysteresis: 0 to 100% of Switch Point
< 2 ms
± 0,3% F.S.
± 0,2% F.S. in Temperature Range 0 to 50 °C
IP40, CE Rating EMC-EN55011 Class B, EN50082-1
< 45 mA, < 25 mA When Utilizing Screen Saver Option
350 Vp, 1, µs
1000 VAC 1 min.
> 100 Mohms at 500 VDC
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Body: Polycarbonate
48 g
223
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Wiring Diagram
Sensor Male
Pin Out
M8 Pin #
1
2
3
4
201
1
2
3
4
Brown:24 VDC
White: Input; PNP (24 VDC)
Blue: 0 VDC
Black: PNP Open Collector Output
Pin #
Red: Vacuum Solenoid Valve + V
Black: Gnd
Red: Break Solenoid Valve + V
Black: Gnd
2
4
3
1
1
2
3
4
Internal Circuit
(Brown) +V (DC 10.8 to 30V)
(White)
Suction/Break Command Input
Digital IN
Max. 125mA
Load
Main Circuit
(Black) OUT 1
+
-
(Blue) OV
1 (Red)
+
-
2 (Black)
3 (Red)
+
-
4 (Black)
Vacuum
Solenoid
Valve
or TR
Break
Solenoid
Valve
Connector for connection of solenoid valve
Connection is finished when Convum is installed
PNP Sourcing
!
Installation
Cautions
The MVS-201 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead to
V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
Error Messages
Display
224
Description
Solutions
Err
Zero Reset Error
3% of F.S.
Reset Zero Below
Contact Factory
Er1
System Error (Internal)
CE1
Over current of Output 1
Load current exceeds
FFF
–FF
Applied pressure exceeds
pressure range
Apply pressures with
the rating of the sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Dimensions
M8, 4-Pin
2 1
9
44
25
12,7
25
15
3
16
3,5
55,5
225
9
5
C
16
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Operating Modes
Description of operation modes and terms on page 180.
Mode: OP1 "Air Conservation / Timer
Mode: OP2 "Vacuum Timer Option"
ON (H-d)
ON (H-d)
PSI
PSI
OFF (h-d)
OFF (h-d)
inHg
inHg
OFF (h-v)
ON (H-v)
(P-v) Peak Limit
OFF (h-v)
ON (H-v)
(P-v) Peak Limit
Input ON
Signal OFF
Input ON
Signal OFF
Blow-Off ON
Solenoid OFF
Vacuum ON
Solenoid OFF
BT
T2
T1
T1
Output 1 ON
N.O. OFF
Blow-Off ON
Solenoid OFF
Vacuum ON
Solenoid OFF
BT
T2
T1
Output 1 ON
N.O. OFF
T1: Optional Vacuum Timer
T2: Optional Blow-Off Delay Timer
BT: Blow-Off Timer
T1: Optional Vacuum Timer
T2: Optional Blow-Off Delay Timer
BT: Blow-Off Timer
Timer Mode OP1
Timer Mode OP2
“Air Conservation / Vacuum Valve Timer”
“Vacuum Valve Timer”
This Vacuum valve control with the use of timing features
conserves air consumption via the vacuum generator nonreturn check valve and sensor hysteresis function. Vacuum
time (t1) can be used to control the vacuum valve for a specific length of time (0,0-9,9 sec.) after output 1 vacuum level
is reached. The vacuum timing function (t1) will remove the
signal from the sensor to the vacuum valve allowing the generator check valve system to conserve air consumption and
vacuum. The vacuum valve will re-open for the same length
of time (t1) when the pressure level drops to the hysteresis
setting (h-v)
(h-v). The operation will continue until the input signal
is stopped. Optional delay timer between vacuum / blow-off
(t2) and blow-off (bt) timer is available. After selecting OP1
OP1,
set bt
bt, t1
t1, and t2 values by using arrow “UP” and “DOWN”
keys. To bypass any of these timing function operations, simply enter 0,00 seconds and the sensor will automatically proceed to the next function.
This mode is ideal for use with CONVUM generators without
check valves. Vacuum timer (t1) can be used to control the
vacuum for a specific length of time (0,00 – 9,9 sec.) after
output 1 is reached. Optional delay timer between vacuum /
blow-off (t2) and blow-off (bt) timer is available. After selectt1, and t2 values by using arrow “UP” and
ing OP2
OP2, set bt
bt, t1
“DOWN” keys. To bypass any of these timing function operations, simply enter 0,00 seconds and the sensor will automatically proceed to the next function.
226
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Operating Modes
Additional Sensor Features
Description of operation modes and terms on page 180.
(Available in All Operating Modes)
Screen Saver Function
(SaV) appears on display. This reduces current consumption
by 20 mA and will activate after 10 seconds.
Mode: OP3 "Signal Controlled Vacuum"
Peak Value Level
H-V / H-d: Switchpoints
h-v / h-d: Switchpoints
P-V: Peak Value
ON (H-d)
(p-u) appears on display. The sensor records this value for
preventative maintenace issues. If this value is not reached
the sensor will display an error message (ALP) indicating
leaks or wear in the system.
OFF (h-d)
Vacuum Level Response Time
PSI
(ut
ut) appears on the display. The sensor records the time
ut
(sec) to reach Output 1 and will display an error message
(ALV) indicating Output 1 has not been reached within the
acceptable time (sec) set by the user.
inHg
OFF (h-v)
ON (H-v)
(P-v) Peak Limit
Input ON
Signal OFF
Blow-Off ON
Solenoid OFF
T2
Blow-off Time
(dt) appears on the display. The sensor records the time
(sec) to complete blow-off cycle and will display an error
message (ALD) indicating (dt) has not reacting within the acceptable time (sec) set by the user.
BT
Vacuum ON
Solenoid OFF
Output 1 ON
N.O. OFF
T2: Optional Blow-Off Delay Timer
BT: Blow-Off Timer
Timer Mode OP3
“Signal Controlled Vacuum”
The vacuum timer option (t1) is omitted and the PLC controls
the input signal time for the vacuum operation. The delay
timer between vacuum / blow-off (t2) and the blow-off (bt)
timers are still available. After selecting OP3
OP3, set bt and t2
values by using arrow “UP” and “DOWN” keys. To bypass
any of these timing function operations, simply enter 0,00
seconds and the sensor will automatically proceed to the
next function.
227
04.10
www.parker.com/euro_pneumatic
C
Vacuum & Pressure Sensors
1 Press
MVS-201
1x
2 1
Operating Mode 1
2 1
Switch Output
2
Operating Mode 2
Operating Mode 3
3
4
2 1
Outmode
Open or
Closed
2 1
Programming Symbols Legend
Operation 1: Air Conservation / Timer
Error Message - Blow-off Time
Operation 2: Vacuum Timer Option
Output 1
Operation 3: Signal Controlled Vacuum
Vacuum Valve (Leave NO)
Blow-Off Timer
Blow-off Release Valve (Leave NO)
Controlled Vacuum Signal with Timer
Screen Saver Function
Blow-Off Activation Timer
Peak Vacuum Level Recorder
Switch Output Value
Vacuum Response Time Recorder
Switch Output Hysteresis Value
Blow-Off Time Recorder
Blow-off Output Value
Normally Open
Blow-off Output Hysteresis Value
Normally Closed
Error Message - Peak Vacuum Level
Low or High Signal to Vacuum Valve
Error Message - Vacuum Response Time
228
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MVS-201
Accessories
M8 Cables for Sensor
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
C
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
MVS-201
(Connects Sensor to Vacuum & Blowoff Release Pilot Valves)
For CVK
CVK-D201G
For MC2
MC2-C201G
229
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Features
MPS-3
Stainless
• Fluids Non-Corrosive to Stainless Steel
SUS 316L or SUS 630
Air
Ammonia
Brake Fluids
Helium
Hydraulic Fluids
Freons
Lubricating Oils
Nitrogen
Water
• Pressure Ranges:
Vacuum .................................. 0 to -1 bar
Positive Pressure ................. 0 to 10 bar
• Sensor Outputs:
2 NPN or PNP Open Collector
Transistor Outputs, 30 VDC, 125 mA
• Switch Point and High-low Programming
Model Number
Output
Pressure Range
MPS-V3F5-PC
2 PNP
0 to -1 bar
MPS-P3S5-PC
2 PNP
0 to 10 bar
• 4 Selectable Units of Measure
(mmHg, -bar, -kPa, inHg)
(kgf/cm2, PSI, bar, kPa)
• Output Response Time Less Than 2,0
Milliseconds
• IP65 Rated and CE Marked
• Error Message
Output Modes
The MPS-3 Stainless Steel Series Sensor has
two independent NPN or PNP open collector
output signals. An analog output is optional.
The Switch Output Mode has a switch point
programmed by the user at a specific
pressure. The Hysteresis Range (h)
adjustment controls the output signal 0 to
100% below the Switch Point (H).
The Window Comparator Mode provides two
Switchpoint Settings (A) and (b) that control
the output signals (NPN / PNP) between two
pressures. This is referred to as the “High /
Low” setting.
Switch Output
0
on
h
off
on
off
H
-1 bar
Window Comparator Output
0
off
A
on
on
b
The optional Analog Output Signal is
calibrated to the pressure scale of the sensor.
off
off
-1 bar
230
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Model Number Index
MPS - V3F
Pressure Range
V3F 0 to -1 bar
P3S 0 to 10 bar
5
5 - P
Port Size
M5F 316SS
C
Circuit
N NPN Sinking
Output
P PNP Sourcing
Output
Electrical Connector
C 4-Pin, M8
G Grommet (2 m)
C
MPS-P3S5-PC
MPS-P3S5-PG
Specifications
Pressure Range
Vacuum (V3F)
Units of Measure
Display Resolution
Media
Pressure Port
Proof Pressure
Operating Temperature
Storage Temperature
Humidity
Electrical Connection
Power Supply
Display
Display Refresh
Output Circuit
Switch Outputs
Output Modes
Output Response Time
Repeatability
Thermal Error
General Protection
Current Consumption
Vibration Resistance
Shock Resistance
Material
Mass
kPa:
Positive (P35)
0,1
MPa:
0,001
Fluids, Non-Corrosive to 316L or 630 SUS
S: MSF 31655
V3F: 10 bar, P3S: 20 bar
0 to 50 °C
-10 to 60 °C
35 to 85% RH
C: 4-Pin, M8 Connector, G: Grommet Open Lead
10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
3-Digit, 7-Segment LED
0,1 to 3,0 sec. (Factory set at 0,1)
NPN (Sinking), PNP (Sourcing) Open Collector Transistor; 30 VDC, 125 mA
2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator
Hysteresis or Window Comparator
< 2 ms with Programmable Increment 32, 128, 1024 ms
± 0,2% F.S.
1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
IP 65 or IP 40, CE Rating, EMC-EN55011 Class B, EN 50082-2
< 55 mA
10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
10 G, XYZ
Housing: Polycarbonate, Wetted Parts: P: 316L or V,R: 630 SUS (Diaphragm)
125 g
231
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Open Collector Wiring
Pin #
1 Brown:24 VDC
2 White: NPN / PNP Open Collector Output
3 Blue: 0 VDC
4 Black: NPN / PNP Open Collector Output
Sensor Male
Pin Out
4
3
2
1
Internal Circuit for Open Collector and Analog Output Wiring
Main Circuit
Tr1
ZD1
Tr2
(Brown) +V
Max. 125mA
(Black) Out 1
Load
Load
(White) Out 2
Max. 125mA
ZD2
D1
ZD2
Tr1
+
DC
– 10.8V 30V
Main Circuit
D1
1K
ZD3
(Brown) +V
ZD1
(Black) Out 1
Tr2
1K
Max. Load
(Blue) OV 125mA
NPN
The MPS-3 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the designer of the system and specifications.
Operating Environment
• Parker / Convum Sensors have not been investigated for ex
plosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive volt
age. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating tempera
tures, and maximum pressure ranges of the system before
installing.
• Installation of air dryer system is recommended to remove
moisture.
DC
– 10.8V 30V
Load
Max.
125mA
ZD3
(Blue) OV
! Cautions
+
(White) Out 2
PNP
• Depending on the system fluid and design, it may be nec
essary to protect the diaphragm against pressure spikes by
installing a flow restriction upstream from the sensor.
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using the metal mounting base.
• To achieve IP65 rating, connect the o-ring and barb to a
normal environment with a 2 mm I. D. tube.
Error Messages
Display
232
Description
Solutions
Err
Zero Reset Error
3% of F.S.
Reset Zero Below
Er1
System Error (Internal)
Contact Factory
Restart Function
Er2
Auto Teach Mode Error
CE1
Over current of Output 1
Load current exceeds
CE2
Over current of Output 2
maximum 125 mA.
FFF
–FF
Applied pressure exceeds
pressure range
Apply pressures with
the rating of the sensor
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Dimensions
5
M5 Female
5
M5 Female
Grommet or M8, 4-Pin
30
M3
4 Places
20
30
20
12,2
4
6,7
M5
M8
C
4-Pin Connector
M3
Venting
Port
MPS-ACCK1
Mounting
Brackets
14
(Included)
14
7
5,5
25
27
28
20
20
20
20
30
43
Ø 4,5
Ø 4,5
13
6
35
5,5
22
233
13
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
See page 181 for Symbol Explanation
1 Hold
Press
2
1x
Press
2x
Output Set Open
or Closed Selecting
Units of Measure
Easy Mode
Activation
4
Press
1x
3
Press
4x
Output Mode 1
Hysteresis or
Window
Comparator
5
Press
Output Mode 2
Hysteresis or
Window
Comparator
3x
6
Output 1
Switch Point
Setting
Output 2
Switch Point
Setting
Hysteresis
Mode
Hysteresis
Mode
Press
5x
Automatic Teach Mode
& Auto Surveillance
Vacuum
Cycle
Window Comparator Mode
Low
High
7
Press
High
6x
8
Press
7x
Display Refresh
Settings / Output
Response Time
Interval
10 Hold
Press
Release
Cycle
Window Comparator Mode
Low
1x
Lock
Hold
Press
9
Press
Display Peak Value
Bottom Value or
Their Difference
1x
Unlock
11
Press
1x
Press
1x
8x
Special Display
Features
12
Press
for 3 Seconds
Zero
Reset
Bottom
Value
Peak
Value
234
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-3
Accessories
Cables
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
C
32
CB-M8-4P-5M-90
Ø 9,7
19
10,7
Ø5
5m
22
MPS-ACCH1
Panel Mounting
Bracket
43,8
40
40
Knockout
33,4
1
36
(+0,5, -0,2)
2
36
(+0,5, -0,2)
235
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-5
Features
MPS-5
Stainless
• Pressure Ranges:
Vacuum .................................. 0 to -1 bar
Positive Pressure .................. 0 to 10 bar
• Sensor Output:
1 to 5 VDC
Output (Volts)
Analog Output
5
1
0
0
Pressure
Max. Rating
• 316L SUS Diaphragm (Positive)
• 630 SUS Diaphragm (Vacuum)
Model Number
Output
MPS-V5FG-AG
Analog
Pressure Range
0 to -1 bar
MPS-V5FG-AGE
Analog
0 to -1 bar
MPS-P5G-AG
Analog
0 to 10 bar
MPS-P5G-AGE
Analog
0 to 10 bar
• Compatible with MPS-7 Display for
Remote Sensing
• IP65 Rated and CE Marked
The MPS-5 Series Transducer is constructed
of 316L or 630 SUS with Analog output capabilities. The sensor can be used as a
standalone unit or in combination with the
MPS-7 Sensor Display. The analog output is
1 to 5 VDC (± 0,04) with accuracy linear
0,5% F.S.
236
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-5
Model Number Index
MPS - V5F
Pressure Range
V5F 0 to -1 bar
P5 0 to 10 bar
Port Size
G 1/4" BSPP Male, M5F
G - A
G
Output Circuit
A Analog 1 to 5 VDC
Electrical Connector
G Grommet (2 m)
GE 2 m Grommet Clip Conn.*
*Use with MPS-7 Series Display
C
MPS-V5FG-AG
MPS-V5FG-AGE
Specifications
Media Liquids and Gases Non-Corrosive to 316SS
Pressure Port G: 1/4" Male BSPP with M5 Female
Proof Pressure V: 10 bar, P: 20 bar
Operating Temperature 0 to 50 °C
Storage Temperature -10 to 60 °C
Humidity 35 to 85% RH
Electrical Connection G: Grommet Open Lead, GE: Clip Type for use with MPS-7
Power Supply 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection
Linear Output Analog Output 1 to 5 VDC
Thermal Error 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C)
General Protection
IP65 or IP40, EMC Rating : EN55011 Class B, EN50082-2
Current Consumption < 20 mA
Spike Protection 400 VP, 1 µs
Dielectric Strength 1000 VAC, 1min.
Insulation Resistance > 100 Mohms at 500 VDC
Vibration Resistance 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs.
Shock Resistance 10 G, XYZ
Material Housing: 303 SUS, Wetted Parts: P: 316L SUS, V: 630 SUS (Diaphragm)
Mass 110 g
237
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
Analog Wiring
Sensor Male
Pin Out
Pin #
1
2
3
4
MPS-5
Brown: 24 VDC
Black: Analog 1-5 VDC
Blue: 0 VDC
Not Used
4
3
2
1
Internal Circuit
Main Circuit
(Brown) +V
(Black) Analog 1 to 5V Output
+DC
- 10.8V to 30V
(Blue) OV
Analog
! Cautions
The MPS-5 Pressure Sensor is designed to monitor pressure
and is not a safety measure to prevent accidents.
The compatibility of the sensor is the responsibility of the
designer of the system and specifications.
• Depending on the system fluid and design, it may be
necessary to protect the diaphragm against pressure spikes
by installing a flow restriction upstream from the sensor.
Installation
• Never insert an object into the pressure port other than an
appropriate fluid connector.
Operating Environment
• Parker / Convum Sensors have not been investigated for
explosion-proof construction in hazardous environments.
• Do not use with flammable gases, liquids, or in hazardous
environments.
• Avoid installing the sensor in locations where excessive
voltage surges could damage or affect the performance of
the sensor.
• Avoid short-circuiting the sensor. Connect the brown lead
to V+ and blue lead to 0 V.
• Do not connect the output lead wires (black / white) to the
power supply.
• Outputs not being used should be trimmed and insulated.
• Install using the metal mounting base.
• To achieve IP65 rating, connect the o-ring and barb to a
normal environment with a 2 mm I. D. tube.
Operations
• Dedicate a power supply of 10,8 to 30 VDC to the sensor
and set the ripple to Vp-p10% or less. Avoid excessive
voltage. Avoid voltage surges.
• A small amount of internal voltage drop is possible. Ensure
the power supply minus any internal voltage drop exceeds
the operating load.
• Verify the operating media is compatible with the specified
sensor. Check the chemical make-up, operating
temperatures, and maximum pressure ranges of the system
before installing.
238
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors
MPS-5
Dimensions
G
1/4" Male Grommet
27
15
Ø 27
40,5
M5 x 1,0
2m
5,2
1/4" BSPP
C
G
1/4" Male Grommet
Clip Connector
27
15
40,5
Connector
(AMP) 170204-15
Ø 27
Housing
(AMP) 171822-5
Shield
M5 x 1,0
5,2
2m
1/4" BSPP
239
04.10
www.parker.com/euro_pneumatic
Vacuum Sensor
P5V-SV
The P5V-SV is an improved adjustable vacuum switch of membrane type, having changeover contact function. Cables are
connected using a DIN 43650A cable set. The switch is capable of withstanding positive pressures up to 35 bar. It is easy to
adjust, has low weight and it is attractively designed.
As delivered, the switch is preset for 75% vacuum.
Specification
Material
Body
Cap
Black anodised aluminium
Thermoplastic
Technical data
Working pressure
Working temperature [°C]
Maximum over pressure
15% to 90% vacuum (-0,15 to -0,9 bar)
-40 to +80
Up to 35 bar
Options and additional information
Repeatability
Hysteresis
±2%
20% of the preset value
(0,15 bar at 75% vacuum)
IP 65
250 VAC/24 VDC
5 A inductive
7 A resistive
Enclosure
Contact loading
Preset value: 75% vacuum
Main data for Vacuum Switch
Symbol
Connection
(vacuum)
Male G1/8
240
Weight
kg
0,090
Order code
P5V-SVVA16K
04.10
www.parker.com/euro_pneumatic
Vacuum Sensor
P5V-SV
Vacuum Switch, P5V-SVVA16K
50
108
Electrical diagram
13,5
20,3
NV 29
10
C
G1/8
19,3
31,6
241
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors – Accessories
CB
Features
• M8, Female
• Length: 2 m or 5 m
• Cover: PVC or PUR
• Connection Type: Swivel Straight or Angled
• IP 67 Swivel Connector
Common Part Numbers
Item
CB-M8-4P-2M
CB-M8-4P-5M
CB-M8-4P-5M-90
Connector
M8 Female
M8 Female
M8 Angled Female
Contacts
4
4
4
Length
2m
5m
5m
Cover
PVC
PUR
PUR
CB-M8-4P-2M
Ø 9,7
Ø5
2m
32
CB-M8-4P-5M
Ø 9,7
Ø5
5m
32
CB-M8-4P-5M-90
Ø 9,7
Ø 9,7
19
10,7
Ø5
5m
22
242
04.10
www.parker.com/euro_pneumatic
Vacuum & Pressure Sensors – Accessories
MPS-ACCH
Panel Knockout Dimensions
Description
For Use With
MPS-3S
MPS-ACCH1
MPS-4
MPS-3
MPS-ACCH7
MPS-31
MPS-ACCH4
MPS-71
MPS-ACCH5
MPS-74
C
MPS-ACCH1, MPS-ACCH7, MPS-ACCH4
43,8
40
40
Knockout
33,4
1
36
(+0,5, -0,2)
2
36
(+0,5, -0,2)
MPS-ACCH5
53,8
50
50
Knockout
1 2 3 4
46
(+0,5, -0,2)
46
(+0,5, -0,2)
243
04.10