Pro Wash

Transcription

Pro Wash
SLB-15310-01-b page 1/4
Hygiene Unit PROWASH - Description
265
100
150
PROWASH 2 PRODUCTS
LB97.12XX
4
5
6
390
8
8
7
13
14
15
F3/4
F3/4
3
115
10 9
WATER
1
F1/2
11
2
© Toute reproduction même partielle est formellement interdite
3
13
12
The Hygiene Unit PROWASH is designed for a intensif cleaning and disinfection of floors and surfaces.
Cover with PROWASH printing
1 Product LB04.0400
SPARE PARTS HYGIENE UNIT PROWASH
Description
Fibre Gasket 1/2" (pack of 10)
Stainless steel wire braided hose. F1/2 x F3/4 L : 1,5m
Strainer washer 3/4" black (bag of 5)
Back plate for hygiene unit 1 or 2 products (PVC)
Cover with printing for hygiene unit 1 product (PVC)
Cover with printing for hygiene unit 2 products (PVC)
Hydraulic hose hygiene unit
Anti pollution ball valve
Venturi 1p+1 NR valve+green injecor+ EPDM o'ring
Venturi 2p+2 NR valve+green injecor+ EPDM o'ring
Non return valve Black / White (EPDM)
Metering tips (pack of 15)
Suction Line L: 2m
Foot filter with weight
Fibre gasket 3/4" (pack of 10)
Blue hose with connections 10m
Blue hose with connections 15m
Blue hose with connections 20m
Blue hose with connections 25m
Blue spray gun with nipple
Index
1
2
3
4
5
5
6
7
8
8
9
10
11
12
13
14
14
14
14
15
Code
LB07.0601
LB03.0118C
LB02.0110
LB06.0102
LB04.0400
LB04.0401
LB10.0400
LB09.003030
LB02.0101
LB02.0102
LB00.0111
LB97.0103N
LB09.D6925M
LB02.0103
LB07.0600
LB97.0115
LB97.0116
LB97.0117
LB97.0149
LB97.0119.E
Cover with PROWASH printing
2 Products LB04.0401
SLB-15310-01-b page 2/4
Hygiene Unit PROWASH - Installation
Hygiene Unit PROWASH
Mounting of strainer washer
1
150
Needed tools :
1 drill Ø 7mm and 1 screw driver
cruciform
3 plugs S7x30
3 screws TCBC 5,5x38
stainless steel
IMPORTANT !
Respect direction of the
strainer washer
Assembly of metering tips
160
2
35
Suction
line
Metering
tip
Non return
valve
WATER PRESSURE
Between 2 and 6 bar
1
1° Push the metering tip in the valve
2° Push the suction line on the valve
Assembly of discharge
hose.
St/st wire braided
hose. 1m50
LB03.0118C
2° Screw nut
Drilling of the caps
160
Can holder 5L
LB97.0114
1 trou Ø10mm
4
Assembly of spray gun.
1° Pull the ring
2° Insert the nipple
of the spray gun
500
© Toute reproduction même partielle est formellement interdite
1° Install the fibre
gasket in the nut of
the hose
4
Fibre gasket ½"
LB07.0601
W
A
L
L
1400 (1m40)
3
2 3
3° Release the ring
IMPORTANT !
Adjust the length of the
hose in order that the
foot filter stays vertically
on the bottom
SOL
These installation dimensions are indicative
PACKING LIST – HYGIENE UNIT PROWASH
1 Hyg iene Unit PROWASH (1 o r 2 p ro d uct s )
1 co nnect io n kit
1 (2 ) Suct io n line L=2 m.
1 St ainles s s t eel wire b raid ed ho s e. F1/ 2 - F3 / 4 L= 1,5m
1 (2 ) Fo o t filt er with weig ht .
1 Dis charg e ho s e with co nnecit o n L= 10 , 15, 2 0 o r 2 5 m (d ep end s o n mo d ell)
1 (2 ) Bag wit h 15 met ering t ip s .
1 Blue Sp ray g un
1 Green injecto r.
1 o r 2 can ho ld ers 5 litres (d ep end s o n mo d ell)
1 kit wit h sc re w a nd o' rings. 1 St rainer was her 3 / 4 ".
1 Technical d ata s heet
2 fib re g as ket s 1/ 2 ".
Dimens io ns o f t he b o x (L x l x h) : 4 50 x 3 9 0 x 2 9 0 mm
2 fib re g as ket s 3 / 4 ".
Weig ht LB9 7.1110 (ho s e 10 m) = 7 Kg
5 (7) s t / s t s crews . Ø 5,5 x 3 7.
Weig ht LB9 7.1115 (ho s e 15m) = 8 ,3 Kg
5 (7) Plas t ic p lug t yp e : S7.
Weig ht LB9 7.112 0 (ho s e 2 0 m) = 9 ,5 Kg
2 (4 ) s t / s t was her t yp e : L5
Weig ht LB9 7.112 5 (ho s e 2 5m) = 10 ,5 Kg
SLB-15310-01-b page 3/4
Centrale PROWASH - Utilisation
SECURITY CONSIGNMENTS
ALWAYS turn the spray gun to the to be treated surfaces
NEVER turn the spray gun to persons, animals or plants.
WAIT a few seconds that w ater and detergent mix up
ALWAYS shut off inlet ball v alv e after each use.
C
A
Shut off ball valve
after each use
B
Fermé
Press for
activation
Ouvert
EAU
2°
4° 7°
6°
1°
Water pressure
between 2 and 6
bar
3°
© Toute reproduction même partielle est formellement interdite
5°
USE
DILUTION CHART - HYGIENE UNIT PROWASH
1) Open the main w ater ball valve " A"
2) Press lever "B" of the spray gun.
3) Turn dow n the lever " C" for sw itching on "WASH" mode.
4) Choose product 1 or 2 (only for version 2 products).
5) Wait a few seconds until the detergent comes up in the suction line
6) Spray as requested.
7) Lift up the lever "C" for sw itching on "RINSE" mode.
8) Rinse.
9) Shut off the main w ater ball valve " A" after each use.
w ithout
11,00%
green
3,20%
grey
10,90%
orange
2,60%
black
10,80%
dark brow n
2,50%
beige
10,50%
yellow
1,80%
red
8,60%
turquoise
1,50%
w hite
6,80%
purple
0,80%
blue
5,50%
pink
0,50%
ligh brow n
4,90%
colorless
0
This chart is done to allow you choose a tip in
function of the needed concentration.
MAINTENANCE
Hygiene Unit PROWASH doesn't suck product
1°_ Check the pressure of the water system (minimum : 2 bar, max : 6 bar)
2°_ Check that the filter gasket is not dirty or scaled. (clean or replace)
3°_ Check that the yellow filter of the suction line is submerged in the product,
and the hose is not pinched, folded, or closed.
4°_ Verify that the tip is not clogged. (clean or replace)
5°_ Check that the yellow filter of the suction line is not dirty. (clean or replace)
6°_ Check that the spray handle is not dirty or calcified. (clean or replace)
The can fills up with water
7°_ Verify that the check valve is not dirty or calcified. (clean or replace)
CLEANING or REPLACEMENT of the venturi
Flat nose
pliers
1°
Plot
GREEN INJECTOR
2°
CLEANING of the Non Return Valve
Ceramic ball
O’ring
NETTOYAGE ou REMPLACEMENT du joint filtre
1_Unscrew the nut of the stainless steel hose
2_Clean or replace the strainer washer
3_Reassemble the filter gasket
RESPECT ORIENTATION
SLB-15310-01-a page 4/4
HYGIENE UNIT PROWASH - VERSION WITH BA DEVICE
PROWASH 1 PRODUCT + BA
PROWASH 2 PRODUCTS + BA
Fig 1
Assembly strainer washer
PROWASH WITH HOSE REEL
Fig 1
Fig 1
BA DEVICE mini BA195
Inlet Min pressure :1,5 bar
Inletmax pressure : 10 bar
Max temberature : 65°C
Assembly : horizontal
Fibre
gasket
40 cm
Outlet
47 cm
175 cm
Evacuation
200 cm
30 cm
© Toute reproduction même partielle est formellement interdite
Inlet
160 cm
Taps
Strainer
Washer
Protective system agains water pollution in interior circuits.
According to the European Directive DIN EN 1717.
Certified DVGW.KIWA. NF. ETA. WRC.
According to the European Directive DIN EN 1717, a maintenant has to be done regulary.
Periodicity: every 1-3 years depending on utilisation conditions.
Operation should be done by a approved company.
These installation dimensions are indicative.
CERTIFICATION N°
DVGW
VA
KIWA
LGA
B ELGAQUA
S t a inle ss st e e l hose .
1004514
Fibre Ga ske t
NG-5123BL0583
BA De vic e
NW- 6305BS 0408
Te flon Va nne
WRAS
VA1.57/ 18697
K20831/ 04
P -IX18345/ I
Be lg 08/ 166/ BA
0806516/ 0807585