Pro Wash
Transcription
Pro Wash
SLB-15310-01-b page 1/4 Hygiene Unit PROWASH - Description 265 100 150 PROWASH 2 PRODUCTS LB97.12XX 4 5 6 390 8 8 7 13 14 15 F3/4 F3/4 3 115 10 9 WATER 1 F1/2 11 2 © Toute reproduction même partielle est formellement interdite 3 13 12 The Hygiene Unit PROWASH is designed for a intensif cleaning and disinfection of floors and surfaces. Cover with PROWASH printing 1 Product LB04.0400 SPARE PARTS HYGIENE UNIT PROWASH Description Fibre Gasket 1/2" (pack of 10) Stainless steel wire braided hose. F1/2 x F3/4 L : 1,5m Strainer washer 3/4" black (bag of 5) Back plate for hygiene unit 1 or 2 products (PVC) Cover with printing for hygiene unit 1 product (PVC) Cover with printing for hygiene unit 2 products (PVC) Hydraulic hose hygiene unit Anti pollution ball valve Venturi 1p+1 NR valve+green injecor+ EPDM o'ring Venturi 2p+2 NR valve+green injecor+ EPDM o'ring Non return valve Black / White (EPDM) Metering tips (pack of 15) Suction Line L: 2m Foot filter with weight Fibre gasket 3/4" (pack of 10) Blue hose with connections 10m Blue hose with connections 15m Blue hose with connections 20m Blue hose with connections 25m Blue spray gun with nipple Index 1 2 3 4 5 5 6 7 8 8 9 10 11 12 13 14 14 14 14 15 Code LB07.0601 LB03.0118C LB02.0110 LB06.0102 LB04.0400 LB04.0401 LB10.0400 LB09.003030 LB02.0101 LB02.0102 LB00.0111 LB97.0103N LB09.D6925M LB02.0103 LB07.0600 LB97.0115 LB97.0116 LB97.0117 LB97.0149 LB97.0119.E Cover with PROWASH printing 2 Products LB04.0401 SLB-15310-01-b page 2/4 Hygiene Unit PROWASH - Installation Hygiene Unit PROWASH Mounting of strainer washer 1 150 Needed tools : 1 drill Ø 7mm and 1 screw driver cruciform 3 plugs S7x30 3 screws TCBC 5,5x38 stainless steel IMPORTANT ! Respect direction of the strainer washer Assembly of metering tips 160 2 35 Suction line Metering tip Non return valve WATER PRESSURE Between 2 and 6 bar 1 1° Push the metering tip in the valve 2° Push the suction line on the valve Assembly of discharge hose. St/st wire braided hose. 1m50 LB03.0118C 2° Screw nut Drilling of the caps 160 Can holder 5L LB97.0114 1 trou Ø10mm 4 Assembly of spray gun. 1° Pull the ring 2° Insert the nipple of the spray gun 500 © Toute reproduction même partielle est formellement interdite 1° Install the fibre gasket in the nut of the hose 4 Fibre gasket ½" LB07.0601 W A L L 1400 (1m40) 3 2 3 3° Release the ring IMPORTANT ! Adjust the length of the hose in order that the foot filter stays vertically on the bottom SOL These installation dimensions are indicative PACKING LIST – HYGIENE UNIT PROWASH 1 Hyg iene Unit PROWASH (1 o r 2 p ro d uct s ) 1 co nnect io n kit 1 (2 ) Suct io n line L=2 m. 1 St ainles s s t eel wire b raid ed ho s e. F1/ 2 - F3 / 4 L= 1,5m 1 (2 ) Fo o t filt er with weig ht . 1 Dis charg e ho s e with co nnecit o n L= 10 , 15, 2 0 o r 2 5 m (d ep end s o n mo d ell) 1 (2 ) Bag wit h 15 met ering t ip s . 1 Blue Sp ray g un 1 Green injecto r. 1 o r 2 can ho ld ers 5 litres (d ep end s o n mo d ell) 1 kit wit h sc re w a nd o' rings. 1 St rainer was her 3 / 4 ". 1 Technical d ata s heet 2 fib re g as ket s 1/ 2 ". Dimens io ns o f t he b o x (L x l x h) : 4 50 x 3 9 0 x 2 9 0 mm 2 fib re g as ket s 3 / 4 ". Weig ht LB9 7.1110 (ho s e 10 m) = 7 Kg 5 (7) s t / s t s crews . Ø 5,5 x 3 7. Weig ht LB9 7.1115 (ho s e 15m) = 8 ,3 Kg 5 (7) Plas t ic p lug t yp e : S7. Weig ht LB9 7.112 0 (ho s e 2 0 m) = 9 ,5 Kg 2 (4 ) s t / s t was her t yp e : L5 Weig ht LB9 7.112 5 (ho s e 2 5m) = 10 ,5 Kg SLB-15310-01-b page 3/4 Centrale PROWASH - Utilisation SECURITY CONSIGNMENTS ALWAYS turn the spray gun to the to be treated surfaces NEVER turn the spray gun to persons, animals or plants. WAIT a few seconds that w ater and detergent mix up ALWAYS shut off inlet ball v alv e after each use. C A Shut off ball valve after each use B Fermé Press for activation Ouvert EAU 2° 4° 7° 6° 1° Water pressure between 2 and 6 bar 3° © Toute reproduction même partielle est formellement interdite 5° USE DILUTION CHART - HYGIENE UNIT PROWASH 1) Open the main w ater ball valve " A" 2) Press lever "B" of the spray gun. 3) Turn dow n the lever " C" for sw itching on "WASH" mode. 4) Choose product 1 or 2 (only for version 2 products). 5) Wait a few seconds until the detergent comes up in the suction line 6) Spray as requested. 7) Lift up the lever "C" for sw itching on "RINSE" mode. 8) Rinse. 9) Shut off the main w ater ball valve " A" after each use. w ithout 11,00% green 3,20% grey 10,90% orange 2,60% black 10,80% dark brow n 2,50% beige 10,50% yellow 1,80% red 8,60% turquoise 1,50% w hite 6,80% purple 0,80% blue 5,50% pink 0,50% ligh brow n 4,90% colorless 0 This chart is done to allow you choose a tip in function of the needed concentration. MAINTENANCE Hygiene Unit PROWASH doesn't suck product 1°_ Check the pressure of the water system (minimum : 2 bar, max : 6 bar) 2°_ Check that the filter gasket is not dirty or scaled. (clean or replace) 3°_ Check that the yellow filter of the suction line is submerged in the product, and the hose is not pinched, folded, or closed. 4°_ Verify that the tip is not clogged. (clean or replace) 5°_ Check that the yellow filter of the suction line is not dirty. (clean or replace) 6°_ Check that the spray handle is not dirty or calcified. (clean or replace) The can fills up with water 7°_ Verify that the check valve is not dirty or calcified. (clean or replace) CLEANING or REPLACEMENT of the venturi Flat nose pliers 1° Plot GREEN INJECTOR 2° CLEANING of the Non Return Valve Ceramic ball O’ring NETTOYAGE ou REMPLACEMENT du joint filtre 1_Unscrew the nut of the stainless steel hose 2_Clean or replace the strainer washer 3_Reassemble the filter gasket RESPECT ORIENTATION SLB-15310-01-a page 4/4 HYGIENE UNIT PROWASH - VERSION WITH BA DEVICE PROWASH 1 PRODUCT + BA PROWASH 2 PRODUCTS + BA Fig 1 Assembly strainer washer PROWASH WITH HOSE REEL Fig 1 Fig 1 BA DEVICE mini BA195 Inlet Min pressure :1,5 bar Inletmax pressure : 10 bar Max temberature : 65°C Assembly : horizontal Fibre gasket 40 cm Outlet 47 cm 175 cm Evacuation 200 cm 30 cm © Toute reproduction même partielle est formellement interdite Inlet 160 cm Taps Strainer Washer Protective system agains water pollution in interior circuits. According to the European Directive DIN EN 1717. Certified DVGW.KIWA. NF. ETA. WRC. According to the European Directive DIN EN 1717, a maintenant has to be done regulary. Periodicity: every 1-3 years depending on utilisation conditions. Operation should be done by a approved company. These installation dimensions are indicative. CERTIFICATION N° DVGW VA KIWA LGA B ELGAQUA S t a inle ss st e e l hose . 1004514 Fibre Ga ske t NG-5123BL0583 BA De vic e NW- 6305BS 0408 Te flon Va nne WRAS VA1.57/ 18697 K20831/ 04 P -IX18345/ I Be lg 08/ 166/ BA 0806516/ 0807585