CaptiveAire`s CASRE Utility Set
Transcription
CaptiveAire`s CASRE Utility Set
Ideal for High Temperature, Heavy Grease Applications The release of the new CASRE unit shows CaptiveAire's commitment to quality, durability and value. This model offers exceptional performance and is designed for usage on high static pressure applications. Both belt and direct drive models are available to meet any application. The CASRE offers a curb mounted exhaust blower system that is easily installed, delivers exceptional performance and offers a tilt-out wheel for easy access when servicing or cleaning the unit. The motor base and shaft seals provide a double layer of protection to prevent leakage into the building and grease build-up on the motor. An automatic safety lock with manual release ensures safe access to the wheel for cleaning. Features & Benefits Ideal for high temperature, heavy grease applications Curb mounted design for easier installation Ventilated motor housing for motor, shaft and drive protection Adjustable motor plate assembly Tilt out wheel - easy access during maintenance, automatic safety lock with manual release Interlocked disconnect switch Non-overloading, welded aluminum backward inclined wheel is statically and dynamically balanced and permits usage on high static pressure applications Heavy duty bearings in excess of 200,000 hours of operation Motor base and shaft seals provide a double layer of protection to eliminate water leaks into the building and grease build-up on motor 2" grease drain fully welded onto discharge elbow Lock and retaining pin - keep wheel centered over the inlet Belt and Direct Drive Options Optional Rain Cap Assembly Additional Product Views Certifications CaptiveAire Systems, Inc. certifies that Models CASRE13 through CASRE24 shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311, and comply with the requirements of the AMCA Certified Rating Program. Models CASRE13 through CASRE24 have been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance. Models CASRE13 through CASRE24 are ETL Listed under file numbers 3049729-001 and 3049729-002 and comply with UL705 (electrical) and UL762 Standards and CSA Std C22.2, No 113. Catalog #112 C June 2012 CASRE13BD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE13BD Performance Curve Max Sizeable RPM = 2200 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 1725 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:09 PM CASRE13BD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE13BD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 Discharge Velocity RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 900 939 833 5.4 / 0.10 1169 9.3 / 0.26 1480 15.1 / 0.49 1744 20 / 0.76 1974 24 / 1.06 1100 1148 1019 8.0 / 0.18 1293 11.5 / 0.36 1565 16.8 / 0.60 1812 22 / 0.90 2033 26 / 1.22 1300 1357 1204 11.1 / 0.29 1435 14.6 / 0.50 1669 19.1 / 0.76 1895 23 / 1.06 2104 27 / 1.41 1500 1565 1389 14.8 / 0.45 1589 18.3 / 0.68 1790 21 / 0.95 1992 25 / 1.27 2187 29 / 1.64 1700 1774 1573 18.9 / 0.65 1749 22 / 0.91 1927 24 / 1.20 2107 27 / 1.53 1900 1983 1758 23 / 0.91 1915 25 / 1.19 2074 27 / 1.51 2100 2191 1943 26 / 1.23 2085 29 / 1.54 2300 2400 2128 31 / 1.62 2174 29 / 1.37 Max Sizeable RPM = 2200 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 1725 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:10 PM CASRE13DD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE13DD Performance Curve Max Sizeable RPM = 1800 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 1725 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:13 PM CASRE13DD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE13DD Performance Table Static Pressure in Inches W.G. 0.000 0.250 0.500 0.750 1.000 1.250 1.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 750 783 696 4.6 / 0.05 904 8.2 / 0.10 1098 11.0 / 0.17 1278 14.0 / 0.25 1442 17.0 / 0.34 1589 21 / 0.44 1720 25 / 0.54 950 991 881 8.1 / 0.10 1050 10.4 / 0.16 1206 12.7 / 0.23 1359 15.4 / 0.32 1506 18.2 / 0.42 1644 22 / 0.52 1772 27 / 0.64 1150 1200 1067 11.1 / 0.17 1209 13.2 / 0.25 1340 15.1 / 0.33 1469 17.5 / 0.42 1595 21 / 0.52 1719 25 / 0.64 1350 1409 1252 14.5 / 0.28 1376 16.3 / 0.37 1490 18.3 / 0.46 1600 21 / 0.56 1709 25 / 0.67 1550 1617 1438 18.1 / 0.42 1547 20 / 0.52 1649 23 / 0.63 1745 27 / 0.74 1750 1826 1623 23 / 0.61 1722 26 / 0.72 Max Sizeable RPM = 1800 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 1725 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:13 PM CASRE15BD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15BD Performance Curve Max Sizeable RPM = 2200 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:14 PM CASRE15BD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15BD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 1200 882 715 4.9 / 0.11 1036 9.4 / 0.30 1281 14.2 / 0.55 1489 18.9 / 0.84 1681 24 / 1.17 1858 27 / 1.53 2024 31 / 1.92 1600 1176 953 8.9 / 0.25 1203 12.6 / 0.49 1427 17.4 / 0.79 1613 22 / 1.12 1778 26 / 1.46 1937 29 / 1.86 2083 33 / 2.27 2000 1469 1191 13.6 / 0.50 1385 16.5 / 0.77 1589 21 / 1.12 1764 25 / 1.50 1918 29 / 1.89 2060 32 / 2.31 2193 36 / 2.76 2400 1763 1429 19.0 / 0.86 1583 21 / 1.16 1761 25 / 1.55 1926 29 / 1.99 2073 32 / 2.44 2800 2057 1668 25 / 1.37 1794 27 / 1.70 1944 29 / 2.12 2096 33 / 2.60 3200 2351 1906 31 / 2.04 2013 32 / 2.40 2140 34 / 2.86 3600 2645 2144 38 / 2.90 2178 36 / 2.33 Max Sizeable RPM = 2200 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:16 PM CASRE15BDHP Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15BDHP Performance Curve Max Sizeable RPM = 2200 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:17 PM CASRE15BDHP Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15BDHP Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 Discharge Velocity RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 1200 882 1111 8.7 / 0.22 1353 12.7 / 0.44 1565 16.8 / 0.69 1752 20 / 0.97 1920 23 / 1.28 1600 1176 1481 15.1 / 0.51 1668 18.9 / 0.80 1841 22 / 1.11 2000 24 / 1.44 2151 27 / 1.80 2000 1469 1852 22 / 1.00 2004 25 / 1.36 2148 27 / 1.73 2073 26 / 1.59 Max Sizeable RPM = 2200 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:17 PM CASRE15DD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15DD Performance Curve Max Sizeable RPM = 1800 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:18 PM CASRE15DD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE15DD Performance Table Static Pressure in Inches W.G. 0.000 0.250 0.500 0.750 1.000 1.250 1.500 1.750 2.000 2.250 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 1200 882 711 5.4 / 0.10 890 7.7 / 0.19 1043 10.0 / 0.29 1171 12.6 / 0.40 1285 15.1 / 0.51 1392 17.6 / 0.64 1493 20 / 0.77 1589 23 / 0.91 1683 25 / 1.06 1600 1176 948 8.9 / 0.23 1079 10.8 / 0.34 1215 13.5 / 0.47 1332 16.2 / 0.60 1435 18.6 / 0.74 1530 21 / 0.89 1619 24 / 1.04 1704 26 / 1.20 1786 27 / 1.36 2000 1469 1185 13.1 / 0.46 1285 15.3 / 0.58 1399 17.7 / 0.73 1506 21 / 0.89 1603 23 / 1.06 1692 25 / 1.23 1775 27 / 1.41 2400 1763 1422 18.4 / 0.79 1503 20 / 0.93 1595 23 / 1.10 1689 25 / 1.29 1779 27 / 1.48 2800 2057 1659 24 / 1.25 1726 26 / 1.41 1773 27 / 1.21 Max Sizeable RPM = 1800 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 2450 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:18 PM CASRE18BD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18BD Performance Curve Max Sizeable RPM = 1700 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3104 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:18 PM CASRE18BD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18BD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 2500 1450 847 10.8 / 0.37 1004 13.1 / 0.63 1135 14.5 / 0.90 1254 17.1 / 1.20 1364 20 / 1.53 1465 23 / 1.88 1562 26 / 2.26 3000 1740 1016 14.5 / 0.64 1153 17.5 / 0.95 1267 19.6 / 1.26 1374 22 / 1.60 1474 24 / 1.96 1568 26 / 2.34 1657 28 / 2.74 3500 2030 1186 19.4 / 1.01 1307 23 / 1.38 1409 26 / 1.74 1505 28 / 2.11 1596 29 / 2.51 1683 30 / 2.92 4000 2320 1355 26 / 1.51 1464 30 / 1.93 1557 32 / 2.34 1643 33 / 2.76 4500 2610 1523 33 / 2.15 1624 35 / 2.63 5000 2900 1693 38 / 2.95 1653 28 / 2.66 Max Sizeable RPM = 1700 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3104 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:20 PM CASRE18BDHP Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18BDHP Performance Curve Max Sizeable RPM = 1800 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3106 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:20 PM CASRE18BDHP Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18BDHP Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 1500 869 693 5.8 / 0.12 895 8.4 / 0.29 1071 10.9 / 0.49 1227 14.3 / 0.72 1366 18.3 / 0.97 1493 22 / 1.23 1608 25 / 1.51 2000 1159 924 9.9 / 0.28 1082 12.3 / 0.50 1224 14.9 / 0.74 1358 18.2 / 1.01 1483 22 / 1.30 1599 25 / 1.60 1708 27 / 1.92 2500 1449 1154 14.8 / 0.55 1285 17.9 / 0.81 1402 21 / 1.09 1516 24 / 1.40 1624 26 / 1.73 3000 1739 1385 22 / 0.95 1496 25 / 1.26 1598 27 / 1.59 1695 29 / 1.94 3500 2029 1616 29 / 1.50 1712 31 / 1.87 1716 27 / 1.80 Max Sizeable RPM = 1800 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3106 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:20 PM CASRE18DD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18DD Performance Curve Max Sizeable RPM = 1700 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3104 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:21 PM CASRE18DD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE18DD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 1500 870 515 3.5 / 0.08 738 6.9 / 0.23 911 9.7 / 0.41 1067 12.7 / 0.63 1212 16.1 / 0.88 1349 19.7 / 1.15 1476 23 / 1.43 1596 26 / 1.73 2000 1160 687 6.1 / 0.18 867 8.9 / 0.37 1015 11.7 / 0.59 1146 14.6 / 0.83 1268 17.5 / 1.10 1385 21 / 1.40 1497 24 / 1.71 1604 26 / 2.05 2500 1450 858 8.7 / 0.36 1007 11.5 / 0.59 1138 14.4 / 0.84 1254 17.2 / 1.11 1362 20 / 1.41 1464 23 / 1.73 1562 25 / 2.07 1656 27 / 2.42 3000 1740 1030 12.0 / 0.62 1155 14.8 / 0.89 1272 17.6 / 1.18 1378 20 / 1.49 1476 23 / 1.81 1567 25 / 2.16 1656 27 / 2.53 3500 2030 1201 15.8 / 0.99 1309 18.6 / 1.30 1414 21 / 1.63 1511 24 / 1.97 1600 26 / 2.33 1685 28 / 2.71 4000 2320 1373 20 / 1.47 1467 23 / 1.83 1561 25 / 2.20 1649 27 / 2.58 4500 2610 1544 25 / 2.10 1628 27 / 2.50 Max Sizeable RPM = 1700 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3104 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:19 PM CASRE20BD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20BD Performance Curve Max Sizeable RPM = 1900 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:21 PM CASRE20BD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20BD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 3500 1626 904 13.7 / 0.84 1046 15.7 / 1.27 1182 18.2 / 1.77 1306 21 / 2.32 1421 24 / 2.91 1529 27 / 3.53 1632 30 / 4.19 4000 1858 1034 17.5 / 1.26 1158 19.4 / 1.74 1280 22 / 2.28 1394 24 / 2.87 1501 27 / 3.51 1602 29 / 4.18 1698 33 / 4.89 4500 2090 1163 22 / 1.79 1273 24 / 2.33 1383 26 / 2.92 1488 28 / 3.55 1588 31 / 4.23 1683 33 / 4.95 5000 2323 1292 26 / 2.46 1391 28 / 3.05 1491 30 / 3.68 1588 32 / 4.37 5500 2555 1421 31 / 3.27 1511 33 / 3.91 1602 35 / 4.60 6000 2787 1550 37 / 4.25 1632 38 / 4.94 1730 34 / 4.89 Max Sizeable RPM = 1900 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:32 PM CASRE20BDHP Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20BDHP Performance Curve Max Sizeable RPM = 2000 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:33 PM CASRE20BDHP Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20BDHP Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 2000 929 696 6.4 / 0.20 888 9.6 / 0.45 1054 13.3 / 0.75 1200 16.7 / 1.08 1331 21 / 1.43 1451 25 / 1.81 1562 29 / 2.20 1668 33 / 2.61 1767 38 / 3.03 1860 42 / 3.47 2500 1161 870 9.8 / 0.38 1027 13.1 / 0.69 1171 16.3 / 1.04 1302 20 / 1.42 1422 24 / 1.82 1534 28 / 2.25 1638 32 / 2.69 1737 36 / 3.14 1832 41 / 3.62 1922 46 / 4.11 3000 1394 1043 13.9 / 0.66 1176 17.4 / 1.02 1302 21 / 1.42 1419 24 / 1.85 1528 28 / 2.30 1632 32 / 2.78 1729 36 / 3.27 1823 40 / 3.78 1911 45 / 4.30 1996 50 / 4.83 3500 1626 1217 18.8 / 1.05 1332 22 / 1.46 1442 26 / 1.91 1547 30 / 2.39 1647 33 / 2.89 1742 37 / 3.42 1833 41 / 3.96 1920 46 / 4.52 4000 1858 1391 25 / 1.57 1491 28 / 2.03 1590 32 / 2.53 1684 35 / 3.06 1775 39 / 3.61 1864 43 / 4.19 1948 48 / 4.79 4500 2090 1565 31 / 2.23 1654 34 / 2.74 1742 38 / 3.29 1828 42 / 3.87 1912 46 / 4.48 5000 2323 1739 38 / 3.07 1820 42 / 3.63 1899 46 / 4.22 1977 49 / 4.85 5500 2555 1913 47 / 4.08 1986 51 / 4.69 1951 47 / 3.94 Max Sizeable RPM = 2000 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:33 PM CASRE20DD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20DD Performance Curve Max Sizeable RPM = 1650 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:34 PM CASRE20DD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE20DD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 3000 1394 770 10.1 / 0.51 961 13.6 / 0.90 1103 17.2 / 1.33 1232 21 / 1.81 1353 24 / 2.33 1468 28 / 2.89 1578 32 / 3.48 3500 1626 898 13.0 / 0.81 1072 16.4 / 1.27 1202 19.8 / 1.74 1319 23 / 2.26 1429 27 / 2.82 1534 31 / 3.42 1635 33 / 4.06 4000 1858 1026 16.1 / 1.21 1186 19.4 / 1.74 1306 23 / 2.26 1414 26 / 2.82 1515 30 / 3.42 1612 33 / 4.06 4500 2090 1155 19.7 / 1.72 1302 23 / 2.32 1416 26 / 2.90 1516 30 / 3.51 1609 33 / 4.15 5000 2323 1283 23 / 2.35 1421 28 / 3.03 1527 30 / 3.67 1622 33 / 4.33 5500 2555 1411 28 / 3.13 1540 32 / 3.88 1641 34 / 4.59 6000 2787 1539 32 / 4.06 Max Sizeable RPM = 1650 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 3875 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:34 PM CASRE24BD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24BD Performance Curve Max Sizeable RPM = 1600 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:35 PM CASRE24BD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24BD Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 4000 1358 674 15.3 / 0.71 822 21 / 1.23 949 27 / 1.83 1060 37 / 2.48 1160 43 / 3.16 1254 50 / 3.89 1342 57 / 4.65 1427 64 / 5.46 5000 1698 842 22 / 1.38 961 28 / 2.00 1075 38 / 2.72 1175 44 / 3.48 1266 51 / 4.28 1351 58 / 5.10 1431 64 / 5.95 1507 71 / 6.84 6000 2037 1010 34 / 2.39 1109 40 / 3.10 1208 47 / 3.93 1300 53 / 4.81 1384 60 / 5.72 1463 67 / 6.66 7000 2377 1179 45 / 3.79 1263 51 / 4.60 1349 57 / 5.53 1433 64 / 6.52 8000 2716 1347 57 / 5.66 1420 63 / 6.56 1508 71 / 6.30 1587 77 / 7.17 Max Sizeable RPM = 1600 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:35 PM CASRE24BDHP Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24BDHP Performance Curve Max Sizeable RPM = 1800 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:36 PM CASRE24BDHP Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24BDHP Performance Table Static Pressure in Inches W.G. 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000 5.500 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 4000 1358 744 11.9 / 0.50 878 13.6 / 0.91 1000 16.6 / 1.36 1111 20 / 1.86 1211 23 / 2.38 1304 27 / 2.94 1392 30 / 3.52 1474 33 / 4.12 1552 36 / 4.75 1627 38 / 5.40 1699 41 / 6.07 5000 1698 930 16.7 / 0.98 1038 18.6 / 1.48 1142 21 / 2.01 1239 24 / 2.59 1329 27 / 3.20 1414 31 / 3.83 1495 34 / 4.49 1571 36 / 5.17 1644 39 / 5.87 1714 42 / 6.60 1781 44 / 7.34 6000 2037 1116 22 / 1.70 1206 25 / 2.28 1295 27 / 2.90 1380 30 / 3.56 1461 33 / 4.25 1539 35 / 4.97 1612 38 / 5.70 1684 41 / 6.47 1751 43 / 7.25 7000 2377 1302 29 / 2.70 1379 31 / 3.37 1456 34 / 4.08 1531 37 / 4.82 1604 39 / 5.59 1674 41 / 6.39 1742 43 / 7.21 8000 2716 1488 37 / 4.03 1556 39 / 4.79 1623 41 / 5.58 1690 43 / 6.41 1755 45 / 7.27 9000 3056 1674 44 / 5.74 1734 46 / 6.59 1794 48 / 7.47 1768 44 / 6.76 Max Sizeable RPM = 1800 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:36 PM CASRE24DD Performance Curve 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24DD Performance Curve Max Sizeable RPM = 1400 RPM. Curve shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:36 PM CASRE24DD Performance Table 1 of 1 http://www.captiveaire.com/CATALOGCONTENT/FANS/EXH_CASRE... CASRE24DD Performance Table Static Pressure in Inches W.G. 0.000 0.250 0.500 0.750 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 Discharge Velocity RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM CFM FPM Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP Sone/BHP 4000 1358 700 13.1 / 0.79 775 14.7 / 1.07 845 16.8 / 1.34 909 18.9 / 1.63 970 21 / 1.93 1028 23 / 2.26 1083 25 / 2.60 1136 27 / 2.97 1187 29 / 3.35 1236 31 / 3.74 1283 33 / 4.15 5000 1698 875 18.8 / 1.54 936 19.9 / 1.90 994 22 / 2.24 1049 24 / 2.58 1102 26 / 2.93 1152 28 / 3.29 1201 30 / 3.68 1248 31 / 4.08 1293 34 / 4.49 1337 36 / 4.92 1380 38 / 5.36 6000 2037 1050 25 / 2.67 1101 26 / 3.10 1150 28 / 3.51 1198 29 / 3.91 1244 31 / 4.32 1289 33 / 4.73 1332 35 / 5.16 1374 38 / 5.60 7000 2377 1225 32 / 4.24 1269 33 / 4.74 1312 35 / 5.22 1354 37 / 5.70 1394 39 / 6.17 8000 2716 1400 41 / 6.32 1329 35 / 4.56 1375 38 / 5.00 Max Sizeable RPM = 1400 RPM. Table shown extended beyond this point for reference only. Max discharge velocity for restaurant applications is 1800 fpm. This equates to 5302 cfm. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Catalog #112C June 2012 8/7/2012 3:37 PM
Similar documents
General Purpose Centrifugal Fan, Model US
moving unit. These units offer many features as standard equipment that other manufacturers consider options. Each unit is fully assembled, factory set at the specified RPM, and test run prior to s...
More information