Quick Drive Mini sheet.indd

Transcription

Quick Drive Mini sheet.indd
Craniomaxillofacial
Trauma, Extremities & Deformities
QuikDrive mini
Battery Powered Screwdriver
Biologics
with Acoustic Feedback
Surgical Products
Neuro & ENT
Existing
Features
• Touch Sensors for continuous,
variable speed control
• Forward and reverse capabilities
• Handpiece maintains “self-lock”
mode until sensors are activated
• Ergonomically balanced for both
left and right hand use
Improvements
• Acoustic Feedback to ensure
battery is attached and device
is working properly
• Standby Mode to minimize
power consumption and
improve battery life
• Improved electrical components
to protect against rigourous
sterilization parameters and
excessive heat
QuikDrive mini
Battery Powered Screwdriver
with Acoustic Feedback
The Stryker QuikDrive mini instrument is designed for inserting 1.2 mm to 1.7 mm bone screws (self-drilling and self-tapping).
The Stryker QuikDrive mini may also be used, in conjunction with a Drill Adapter, for drilling pilot holes in non-dense bone for
1.2 mm to 1.5 mm screws.1
• Fast coupling for Hex-Shaft
Blades and Drill Adapter
The Stryker QuikDrive mini is
intended for inserting 1.2 mm to
1.7 mm Stryker bone fixation screws
(self-drilling and self-tapping)
The sterilization tray offers
convenient storage
and sterilization in one
compact unit.
The drill adapter
allows for Stryker J - Latch or
Dental end drill bits.
Automatic System Check
• QuikDrive mini will perform an automatic system check, when Battery Pack is attached to the handpiece
• An acoustic signal gives feedback about the current status of the QuikDrive mini
• If the QuikDrive mini is attached to the Battery Pack and is not used for a period of 15 minutes, the device will enter a standby
mode to conserve battery life
Neuro
AcousticInstruments
Signal
Description
1
Cause
Action
[**]
2 high tone beeps
System check was successful
Device is ready for use
[ *- - ]
1 high and 2 low tone beeps
At least one of the QDm sensors
is damaged or misaligned
Remove and reattach the Battery Pack –
DO NOT press any control buttons (sensors) for
up to 2 sec. after the Battery Pack is attached
and the QDm beeps again. IF the device beeps
again with one high and two low tones [ * - - ],
call Stryker and return the device.
[--]
2 low tone beeps
QDm device is too hot and is going
into temperature protection mode
Wait until QDm has cooled down to room
temperature and reattach the Battery Pack
[*]
1 high tone beep
QDm is in standby mode
Remove and reattach the Battery Pack
The QuikDrive mini is suitable for screwdriver blades of the Universal Neuro 2 and/or Universal Neuro 3 System including the CMF Universal 2 System.
• Touch Sensor Controls,
forward and reverse
The battery pack
is packaged sterile,
for single use.
Ordering Information
The sterilization tray offers
convenient storage
and sterilization in one
compact unit.
Number
Description
62-50101
QuikDrive mini
62-50113
QuikDrive Battery Pack
62-50104
Drill Adapter - Dental
62-50105
Drill Adapter - J-Latch
29-15030
QuikDrive Sterilization Tray
The Stryker QuikDrive mini is a cordless, sterilizable handpiece (uses a disposable Battery Pack) that assists in drilling and the
placement of bone fixation screws. The handpiece contains two force-sensitive buttons, which allow for variable speed control in the
forward and reverse directions. The handpiece maintains the „self-lock“ mode (the drive shaft does not rotate) until one of the force
sensitive buttons is pressed. Two types of drill adapters (for Dental and J-Latch coupling twist drills) are available to allow drilling of
pilot holes in non-dense bone.
Trauma, Extremities & Deformities
Biologics
Surgical Products
Neuro & ENT
Spine
Stryker Leibinger GmbH & Co. KG
Boetzinger Strasse 41
D-79111 Freiburg
Germany
Phone: +49 (0) 7 61 45 12-0
Fax: +49 (0) 7 61 45 12-120
www.stryker.com
This document is intended solely for the use of healthcare professionals. A surgeon must always rely on his or her own
professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker
does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using
it in surgery. The information presented in this brochure is intended to demonstrate a Stryker product. Always refer to the
package insert, product label and/or user instructions including the instructions for cleaning and sterilization (if applicable)
before using any Stryker products. Products may not be available in all markets. Product availability is subject to the regulatory
or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about
the availability of Stryker products in your area. This document is not for the distribution in the USA.
Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following
trademarks or service marks: Stryker, QuikDrive, Universal.
All other trademarks are trademarks of their respective owners or holders.
The products listed above are CE marked.
Literature Number 90-97043
LOT A4911
Copyright © 2011 Stryker
Printed in the USA
1275