DEWETRON D310 brochure

Transcription

DEWETRON D310 brochure
Automotive
Energy & Power Analysis
Aerospace
Tr a n s p o r t a t i o n
G e n e r a l Te s t & M e a s u r e m e n t
PORTABLE SIDEHAND / D310 SERIES
D310 series instruments
Portable Data Acquisition Systems
With the D310 series we set out to reinvent the DEWETRON
data acquisition platform at the lowest possible price point.
But we gave our engineers a seemingly impossible task:
don’t cut any corners or sacrifice recording capabilities.
Key Features
Portable, modular data acquisition instruments
100 kS/s/ch @ 16-bit resolution
Fast data streaming up to 105 MB/s to SSD
The result is the D310 series from DEWETRON, available
at approximately 50-60% of the normal price of an equivalent
system, and yet with every great feature and capability that
you’ve come to expect from DEWETRON.
Expandable to 96 channels
The D310 is flexible: it can hold either 16 x MDAQ series
DIFFERENTIAL signal conditioning channels, or 8 x DAQP
/ HSI series ISOLATED plug-in signal conditioners. And
because there’s a DEWETRON ORION series card inside,
you’ve got synchronous counter/encoder inputs, plus digital
input and output lines automatically.
Optional CAN BUS, ARINC 429, 1553, and PCM
interfaces
At the time of ordering you can choose a 15” touchscreen
display to be added to the top cover (or plug in whatever display you like). A battery/UPS option is also available, which
attaches to the bottom of the chassis to provide 2 hours of
running time in the event of a power outage. It’s got tie-down
points on every surface, and comes with a shipping case.
Upgradable to 5 MS/s/ch max sample rate
Easy to use, intuitive software
2 synchronous counter inputs (8 max.)
Optional video cameras and inertial sensors
Optional battery power / UPS
Optional solid state HDD
Tough shipping case included
MIL-STD construction, made in USA
Online Information
www.dewamerica.com/D310
The D310 is truly an evolution in providing DEWETRON
power and performance at an amazing price point.
www.dewetro n .us
1
PORTABLE SIDEHAND SERIES
D310 Overview (with DAQ or MDAQ conditioners)
8 slots for DAQ / HSI /
PAD series modules
(INSIDE) ORION-1616-100
A/D card included as standard
310-DISP 15” touchscreen
display (OPTIONAL)
(INSIDE) Optional interfaces
for ARINC, 1553, CAN,
IRIG, GPS, etc.
310-UPS battery / UPS
compartment (OPTIONAL)
(or two MDAQ-SUB 8
channel conditioners)
EPAD2 signal conditioners
for adding slow thermocouple
inputs, RTDs, voltages,
and currents (daisy-chain)
Video cameras like:
DEWE-CAM-FW-70
DEWE-CAM-GIG-E-120
DEWE-CAM-USB, etc.
PCI card edge access (for
ARINC, 1553, D/A cards)
9-29 VDC power
input connector
Hard tie-down points
on four sides
High-impact rubberized
side / corner protectors
2
Computer interfaces
(ethernet, USB, RS232,
audio, and more)
TWIN Removable
2.5” drives:
120 GB SSD (C)
500 GB HDD (D)
www.de wam eri ca .com/ D310
System architecture at a glance
... it´s all about DEWE-ORION and system clock
DEWECAM-01
DAQ or MDAQ
modules
ORION A/D card
Signal
conditioning
Sensor
Analog
Inputs
Sensor
supply
Counter
Inputs
Digital
Inputs
Digital
Outputs
DEWE-CLOCK
ext.
Clock
int.
Clock
ARINC 429
data
1553 data
PCM data
e.g., sensors that output via serial bus
RS232
e.g., GPS position sensors, webcams, etc.
USB
e.g., webcams,
MiniDV cameras
Custom
Sensor Supply
e.g., data from
other systems
Firewire
CHASSIS
CPU/
RAM
SOFTWARE
DS-7 or
LabVIEW
Software sync of various PC bus interfaces (USB, ethernet, firewire, RS232...)
External Time
Source
INDUSTRIAL-PC
PORTABLE SIDEHAND / D310 SERIES
CAN
Ethernet
3
D310 Power Applications
PORTABLE SIDEHAND SERIES
Testing high voltages requires our DAQ and HSI series HV modules
You can configure your D310 with any 8 of our DAQ and HSI series high voltage modules, and directly input up to ±1400V into the
D310. DAQP-HV modules provide 300 kHz bandwidth, while the HSI-HV version provides 2 MHz bandwidth! When high bandwidth is
needed we recommend to upgrade the ORION card to our 1 MS/s/ch card (UP-ORION-100-1000 or UP-ORION-100-1000-8 if only 8
channels are needed). DAQP-LV and HSI-LV modules work perfectly with our current clamps and flexible coils, allowing you to make
precision voltage and current measurements with your D310. Add the DS-OPT-POWER software option and unlock a whole world
of power and energy related calculations and on-line displays, including active and reactive power, power factor, harmonics and
interharmonics,and more.
Typical Power and Energy Applications:
Rod Drop Testing at Nuclear Plants
Power Plant Trouble-shooting
Rail Car Substation Power Monitoring
Hybrid-electric Vehicle Testing
Key DEWETRON capabilities
Calculation of all common power parameters
(power factor, active, reactive, apparent power,
harmonics, interharmonics, flicker, et al)
Portable, lightweight, easy to move around
Built-in UPS option for continuous monitoring
Advanced triggering, including triggering on RMS,
frequency changes, and more
D310 with 310-DISP option and plug-in DAQ
ISOLATION modules
DAQP-HV and HSI-HV modules
The DAQP-HV is a plug-in module that provides 300 kHz bandwidth, and measuring ranges from
±20V to ±1400V, with 1800 Vrms line-to-line isolation and 1.4kV line-to-ground isolation. It is the
perfect amplifier for most power and energy measurement applications.
Need higher bandwidth? Choose the HSI-HV module, which increases the bandwidth to 2 MHz,
while retaining the high voltage ranges and powerful isolation.
Both versions of the HV module are availale with insulated safety type banana jacks, or optional
screw terminal connectors for fixed installations.
Great software capabilities
The DS-OPT-POWER software
option adds the kinds of displays
and calculations that you need
for the most demanding energy
analysis applications.
Screen setup is fast and easy.
Create whatever you like in
moments. Save everything to an
unlimited number of setup files.
A separate data base option allows
you to write RMS and event values
to a SQL data base. Multiple DEWE
systems can be located across a
wide geography, and all write back
to a common location.
4
www.de wam eri ca .com/ D310
D310 Aerospace Applications
In the air or on the ground, Dewetron is involved in your most demanding testing needs
The D310 is right at home in your test chamber, hooked up to strain, pressure, acceleration, force and temperature sensors. In
addition you can input voltage and current, 4-20mA transducer outputs, and virtually every signal and sensor type. Whether you're
doing engine tests on the wing, in the SIL, or in the chamber, we are there. Recorder and X-Y graphs make plotting physical
parameters graphical and easy. Connect up a video camera and see what the test looked like. If you are flying, the D310 is small
enough to fit into most aircraft, and easy to operate either directly from its front panel, or via remote desktop connection. GPS and
IRIG time code capabilities complete the suite of input requirements of these applications, allowing you to record your data in sync
with absolute time, and to plot your position on a map.
PORTABLE SIDEHAND / D310 SERIES
Typical Aerospace Applications:
Engine testing on the ground or on the wing
Component and subsystem tests of all kinds
Structural analysis via strain, force, and more
Wind tunnel tests with 24-bit ADC and accels
SIL testing applications
Key DEWETRON capabilities
Easy to plot data in perfect sync with IRIG / GPS
time
Portable, lightweight, easy to move around
Optional UPS option for continuous monitoring
Advanced MATH functions can be applied during
recording - or afterwards - in any combination
D310 with 310-DISP option and 310-UPS battery
option
ARINC 429 and MIL-STD-1553 interfaces
Dewetron offers a wide variety of ARINC and 1553 interfaces for the D310. These are installed
inside the chassis in the form of a PCI card. The connectors are on the right side of the D310 for
easy hook up to your aircraft data bus.
ARINC cards: with 4, 8, 16 and 30 4 Shared Tx/Rx Channels of ARINC-429
1553 cards: with 1, 2, 3 or 4 channels of Dual Redundant MIL-STD-1553 with Dual Function (BC/
Mon or mRT/Mon) Capability - or with FULL Function (BC/mRT and Mon) Capability
Dynamic display capability
The software includes graphical
diplay objects such as an attitude
indicator, y/T, X-Y, scope, FFT,
digital meters, analog meters, bar
graphs, and more. You can create
exactly the kind of display that you
need to best visualize your test
results - in real time!
Multiple displays can be created
and used within the same setup
file. You can even change from
one display to another during
recording - there's nothing
stopping you from seeing data the
way that you need to.
5
D310 Automotive / Vehicle Applications
PORTABLE SIDEHAND SERIES
Test track and test chamber applications abound
Dewetron started out as a company making systems for the automotive makers of Europe, so this application area is deep within our
bones. The D310 is ideally suited for testing applications in cars, trucks, trains - basically anything that rolls along on the ground. We have
deep application knowledge in the areas of dynamic testing, structural analysis, vehicle data bus technology (CAN, Flexray, XCP, to name
a few), functional safety, active and passive safety systems, combustion analysis, and so much more.
Our GPS implementation is second to none, allowing you to record sensor data in perfect sync with your speed and position on the
earth. Use the PLUGIN-POLYGON software option to create a virtual three-dimensional world on the screen that your vehicle can move
on. Whether you're testing cars, trains, busses, motorcycles, or military vehicles, Dewetron is there. The wide DC input range of the D310
makes it ideally suited for in-vehicle applications.
Typical Power and Energy Applications:
Vehicle dynamics & Durability
Safety, CAPS, ACC and FuSI testing
Combustion analysis
Hybrid/electric vehicle test
Train / Railcar testing
Military vehicle R&D
Race car R&D
D310 with 310-DISP option, plug-in DAQ ISOLATION
modules, and 310-UPS battery option on the bottom
Key DEWETRON capabilities
Advanced options for COMBUSTION, and integration
with high accuracy gyro sensors (ADMA)
Portable, wide DC input power range
Built-in UPS option for continuous recording
Mature GPS and VIDEO integration at the hardware
and software level
CAN BUS interfacing, plus optional Flexray and XCP
over ethernet
GPS integration at the lowest level
With the DEWE-CLOCK and GPS antenna, your recordings
will be made with reference to vehicle position and speed.
In addition, GPS provides a common time sync of multiple
DEWETRON systems even at different locations, and not
connected to each other.
Isolated inputs for perfect measurements
DAQ and HSI series signal conditioners provide the highest
galvanic isolation of your signals (up to 1.8 kV line-to-line),
ensuring that your signals will not be adversely affected by
ground loops, crosstalk, and other problems so common
in the testing environment. Trust DEWETRON systems like
the D310 to provide perfect test results every time.
Dewetron GPS technology with
update rates up to 20 Hz can be
built into the chassis of the D310.
For higher update rates we offer
the external VGPS-200 and VGPSHS systems, with 20/200 and 100
Hz update rates respectively.
6
www.de wam eri ca .com/ D310
Counter input features
DEWETRON has advanced the stateof-the-art in counter/encoder inputs in
our data acquisition systems, improving yet again our ORION-counters.
ADC-clock
Counter input
The key advancement is that our
counters are PHASE SYNCHRONIZED.
Referring to the diagram, you can see
that a standard counter is always a
sample behind. With software interpolation you can get closer, but only
with DEWETRON’s advanced time
shifting technology are both the
phase and amplitude fully corrected!
Ideal counting
ORION-counter
Software interpolation
Standard counter
PORTABLE SIDEHAND / D310 SERIES
RPM-Measurement
Encoder
Tacho
Gearthooth, CDM
Gearthooth, TRG, CDM and TRG
Gearthooth with missing teeth
Gearthooth with double teeth
Length-measurement
Linear encoder
Linear pulse sensor
Event Counting
Basic counting
Gated counting
Up/down counting
Waveform Timing
Period frequency
Two pulse edge separation
Period, pulse width,
frequency, duty cycle
7
PORTABLE SIDEHAND SERIES
D310 System Specs
Portable, powerful, tough
Flexible signal conditioning
100% modular design
Optional batteries/UPS
SureHAND basic specifications
Input specifications
D310 with DAQ conditioners
Slots for DAQ or PAD modules
MDAQ-SUB positions
D310 with MDAQ conditioners
8
--
N/A
2 (16 channels)
Main system
Total PCI slots
2 x half-length PCI slots (optionally converted to 2 x PCIe slots)
Hard disk
Removable 120 GB SSD (C) and removable 500 GB HDD (D) (both can be upgraded)
Data throughput to disk
50 MB/s typical; up to 105 MB/s using SSD 240 GB iMLC
Power supply
9~29 VDC. Includes external AC/DC power adapter.
Battery power (option 310-UPS)
Adds a battery compartment with 4 SideHAND2 series hot-swappable batteries, and connecting cable.
Display (option 310-DISP)
15” XGA display, 1024 x 768 px, with resistive touchscreen
Processor
Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX mainboard
RAM
8 GB standard
Ethernet
3 x ethernet interfaces (1 Gb)
USB interfaces
4 x USB 3.0 ports AND 2 x USB 2.0 ports
Display output ports
2 x DisplayPorts and 1 x DVI output for connecting an external display
Operating system
Microsoft Windows7™ Professional, 64-bit operating system
Dimensions (W x D x H)
14W x 10.5D x 4.25H (inches) / 355 x 267 x 108 (mm)
Weight
8 kg typical (17.6 lbs)
Free PCI slots
1 (the standard ORION-1616-100 A/D card uses one of the two PCI slots)
Environmental specifications
Operating temperature
-20 to 50C (0 to 45C with batteries installed) (storage temp -20 to 60C)
Humdity
10 to 80% non-condensing, 5 to 95% relative humidity
Vibration
MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
MIL-STD-810F, EN 60068-2-27
Required to complete this
model
Conditioners:
A/D card(s)
Software
Any 8 DAQ series plugin modules
The ORION-1616-100 is included as
UP-ORION-16-22
upgrade
UP-ORION-16-24
upgrade
UP-ORION-16-22-32
upgrade
UP-ORION-100-1000
upgrade
UP-ORION-100-200-8
upgrade
UP-ORION-100-1000-8
upgrade
UP-ORION-100-5M-8
upgrade
Any two MDAQ-SUB modules
standard. You may upgrade this card as follows:
the resolution to 22-bits, add antialiasing filters (AAF), max. SR remains at 100 kS/s/ch
the resolution to 24-bits, add AAF, max. SR increases to 200 kS/s/ch
the resolution to 22-bits, add AAF, increase from 16 to 32 analog channels
the max. SR to 1000 kS/s/ch
the resolution to 24-bits, add AAF, max.SR increases to 200 kS/s/ch, decrease to 8 channels
the max. SR to 1000 kS/s/ch, decrease to 8 channels
the max. SR to 5000 kS/s/ch, decrease to 8 channels
DS-7-SE data acquisition software is included as standard*
32 analog channels, or multiple video cameras, or DEWE-CAM-FW-70, or DEWE-CLOCK use requires upgrade to PROF edition.
64 analog channels requires upgrade to DSA edition.
LabVIEW VIs are available for Dewetron ORION series A/D cards and DAQ series signal conditioners.
Popular upgrades
Counter expansion (UP-ORION-CTR8)
Synchronization interface (UP-ORION-SYNC)
Upgrades the A/D card from 8 TTL digital I/Os and 2 TTL counter / encoders to:
8 synchronous TTL digital inputs protected up to 25 VDC
8 synchronous counter / encoder or 24 digital inputs with programmable threshold levels (0-40 V), input voltage range -35 to 60 V, AC/DC coupling
Includes DB37 pin connectors installed
Installs the SYNC hardware input/output ports and LED indicators onto the mainframe. Allows systems with the same base ORION card to be
synced. Additionally Requires DS-OPT-NET software option for synchronization under DS-7 software.
Digital Isolation (ORION-BASE-DI-ISO)
HDD upgrade to solid state disks
Isolation for the 16 digital inputs of ORION base cards.
Input low: 0 - 2 V, Input high: 3 - 50 V bandwidth: DC up to 1MHz
Isolation voltage between channels: 150 VDC, Isolation voltage between Input and Output: 250 VDC
Connector: DSUB-37 connector (replaces standard digital I/O connector)
HDD-UP-SSD-120
HDD-UP-SSD-240
HDD-UP-SSD-480
Upgrade to 120 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 90 MB/s
Upgrade to 240 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 90 MB/s
Upgrade to 480 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 100 MB/s
Popular interface add-ons
CAN expansion (UP-ORION-CAN2)
IRIG / GPS time code (DEWE-CLOCK-INT)
Adds 2 synchronous high speed CAN bus interfaces to the ORION card inside the system. Includes two DB9 factory installed connectors for
these counters on the side panel of the D310, and rear panel of the DEWE-3040 and DEWE-3050. Includes DS-OPT-CAN software option supporting CAN BUS interface.
IRIG or GPS synchronized clock source for DEWETRON systems, installed inside a new DEWETRON base unit
Input: IRIG signal code A or B, AM or DC, or GPS signal
Output: TTL clock from 10 Hz to 10 MHz, PPS and ORION-DSA-SYNC, IRIG-B DC (requires DS-PROF or higher)
Please order GPS antenna GPS-ANT-1 separately (if GPS is needed)
VIDEO-FG-4
Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs for analog NTSC video input on the right side panel, allowing four video
streams to be recorded in sync with the data
ARINC-429 / 1553 interfaces
Adds a multi-channel ARINC-429 or MIL-STD-1553 interface to the system. Available as a single PCI card with either or both interfaces on it, or
as separate external USB interfaces. See the INTERFACES section for a comprehensive list.
External channel expansion
EPAD2 and CPAD2 series modules
8
Add one or more EPAD2 series external signal conditioners to your system. Each one provides 8 thermocouple, RTD, low voltage, or low current inputs. EPAD2 modules can be daisy-chained up to 8 modules per system. CPAD2 modules are the same except with CAN BUS interface.
www.de wam eri ca .com/ D310
Additional Specifications
DS-7 Software Specifications
DS-7 data analysis specs
Number of analog channels
8 channels
MATH channels
Bit-resolution
16-bit ADC converters (one per channel)
14.7 effective number of bits
Maximum sample rate
100 kS/s/ch simultaneous
Input configuration
Single-ended (note that the DAQ, HSI, or MDAQ conditioners are in front of the ORION card, and serve as the
differential front-end for your signals.
MATH can be created before or after recording
Channels created before can execute during recording,
or can be executed afterwards
Channels created afterwards can be executed any time,
across all data or just a portion of the data
All MATH channels can be saved into the data file
MATH functions (standard)
Operators: +, -, /, x, ( ),^
Statistics: RMS, AVE, RMS, STD DEV, MAX, MIN
Trigonometry: SIN, COS, TAN, PI, ACOS, ASIN, ATAN
Functions: ABS, SQR, SQRT, SGN, TRUNC, ROUND,
RND, LOG2, LOG10, LN, EXP
Trigonometry: <, >, =, <=, >=, NOT, AND, OR, XOR
Signals: SCNT, SR, TIME, SINE, SQUARE, TRIAN,
NOISE
Measure: Pulsewidth, Stopwatch, Measdiff, Edge, ECNT,
ICNT, HOLD, TRIG, IF
Events: KEYPRESSED (any key can be used in math)
Software FILTERING
IIR and FIR software filters can be created for any channels, and executed during acquisition or afterward
Band pass, band reject, low-pass or high-pass
Up to 10th order
Bessell, Butterworth, or Chebychev protocols
Also: FFT filter function
Integration, Differentiation
INT, DINT, DER, and DDER with selectable orders and
scaling factors
Non-linear processing
Polynomial scaling with up to 10 section coefficients
Exact frequency function
Within 0.001 Hz resolution frequency measurement from
any analog channel, via software
Reference curve function
Y-T reference curve, X-Y reference curve, and FFT
reference curve. Detect signal out of bounds and report
an error, which can be counted and displayed using the
ECNT math function and display functions
Constant function
User-definable constants can be used in math channels,
and displayed in meters
ADC type
Successive approximation (SAR)
Channel separation (cross-talk)
> 90 dB @ fin 1 kHz
DC accuracy
±0.02 % of reading ±0.013 % of range
Signal to noise
89 dB
THD (fin = 1kHz) 0 dBFS input < -86 dB
THD (fin = 1kHz) -20 dBFS input < -93 dB
Interchannel gain mismatch
±0.015 %
Interchannel phase mismatch
0.02° * fin (kHz) + 0.08°
Digital I/O and Clock line specs
Digital input lines
16
Digital input characteristics
TTL/CMOS signal levels:
Low voltage level -0.7 V to 0.8 V
High voltage level 2 V to 5 V
Pull-up with 100 kΩ resistor
Input capacitance < 5pF
Input protection -1 V to 6 V
Digital output lines
8
Digital output characteristics
TTL/CMOS signal levels:
Low voltage level < 0.4 V @ 4 mA load
High voltage level > 3 V @ 4 mA load
Output current
Sink (low level) -20 mA Source (high level) 20 mA
Output impedance 50 Ω
Clock divider output line
PORTABLE SIDEHAND / D310 SERIES
ORION-1616-100 analog input specifications
1, same characteristics as digital output lines
DS-7 display specs
Standard counter/encoder specs
Standard counter/encoders
2 x 32-bit (LEMO connectors for each)
Note - used as pair counters when advanced features
are used. If you need two or more full-featured counters,
please order the UP-ORION-CTR8
Counter timebase
80 MHz (40 MHz max. input frequency)
Time base accuracy
25 ppm
Measurement modes
Event counting, up/down counting, gated event counting,
period time, pulse width, two-edge separation, frequency
and encoder measurements
Standard counter/encoder signal levels
TTL/CMOS, pull-up with 100 kΩ
Input low level: -0.7 V to 0.8 V
Input high level: +2 to +5V
Overvoltage input protection
(DI 0 to DI 7): ±25 V continuous
(DI 8 to DI 15): -1 to 6 V
Display screens
Default screens: overview, recorder, scope, FFT
User can freely define these screens, and add more
screens (no preset limit). Screens can be named freely
and assigned icons. Screens can be rearranged on the
taskbar.
Display objects (standard)
Horizontal recorder graph, vertical recorder graph, scope
graph, X-Y graph, digital meter, analog meter, bar graph,
status lamp and text indicator, FFT graph, 2D and 3D
graph, video window, GPS track
Display objects (DSA option)
Third-octave graph (also 1/1, 1/3, 1/6, 1/12, 1/24)
Orbit display
Display objects (POWER option)
Vector scope and harmonic FFT (V and A, based on harmonics of the base power frequency)
Limits visual alarms
Digital and bar graph meters can be set to change colors
when signals exceed high or low limits
Analog meter can be set with one or two “red lines”
Status lamps can be set to change colors based on
levels
Indicators can be set to display different text messages
based on discrete levels being reached
Advanced counter/encoders (UP-ORION-CTR8 option)
Advanced counter/encoders
8 advanced 32-bit counters
Counter timebase
80 MHz (40 MHz max. input frequency)
Measurement modes
Event counting, up/down counting, gated event counting,
period time, pulse width, two-edge separation, frequency
and encoder measurements
Signal levels
Symmetrical, differential
AC/DC coupling selectable
Trigger adjustment range
0 to 40 VDC with 40 mV resolution
Trigger level accuracy
±100 mV ±1% of trigger level
Common voltage range
-35 to 50V
Overvoltage input protection
±100 V continuous
Max. DC level @ AC coupling:
±50 V continuous
CAN BUS specs (UP-ORION-CAN2 option)
High-speed CAN interfaces
2 CAN 2.0B high speed interfaces
Bus pin fault protection
±36 V
ESD protection
12kV
Physical layer
High speed
Compatibility
2.0B standard, J1939 protocol support
OBD II via software option
DS-7 top level functions
Basic functions
User-defined sequences can load setup files, wait for
events or signal levels, ask the user for input, go to next
steps or back based on inputs of all kinds, access virtually any DEWESoft function, start or stop the acquisition,
play Windows media (sound or video)
Security function
Password(s) can be set to protect setup mode. Two
access levels can be utilized.
Project definition
Different hardware configurations can be defined as
“projects,” and freely edited and recalled any time
Setup definition
Each setup file contains all of the hardware configuration
selections (channel range, scaling, etc) as well as storage mode, sample rate, trigger settings, and all display
settings of all screens. Millions of setups can be defined,
edited, and recalled.
9
Channel Expansion
PORTABLE SIDEHAND SERIES
You can select between expansion by:
Analog cable
PCI expansion
Expansion via Ethernet
Channel expansion by analog cable
DEWE-ORION card
in the D310
A very popular way of expanding the analog inputs is
to install more ORION cards into the instrument and
connect external signal conditioning amplifiers via
analog cables. Each D310 instrument has two spare
PCI-slots which can be used to install additional
ORION cards. Select a suitable external DEWE-30
or DEWE-31 series signal conditioning rack, the
required amplifiers and directly connect the analog
outputs to the ORION cards by analog signal cables.
AN
PO
User tip: The standard analog cable length is
2 m but these can be as long as 15 m.
Specifications
DEWE-30-8
A LO
WE
ALS
G SIGN
PP
R SU
LY
AC (optional DC)
power supply
DEWE-31-12
DEWE-30-16
DEWE-30-32
DEWE-31-16
DEWE-31-32
DAQ/PAD/HSI slots
8
16
32
--
--
MDAQ channels
--
--
--
16
32
95 ~ 260VAC
50/60 Hz
From the ORION
(10-36 VDC)
95 ~ 260VAC
50/60 Hz
Wide range DC power (11 to 32 VDC)
N/A
Wide range DC power
(11 to 32 VDC)
Power supply
Optional power supply
Dimensions W x D x H
230 x 181 x 104 mm
9.1 x 7.1 x 4.1 in.
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
435 x 223 x 245 mm
17.1 x 8.8 x 9.6 in.
208 x 95 x 108 mm
8.2 x 3.7 x 4.3 in.
435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in.
3 kg (7 lbs)
4 kg (9 lbs)
7 kg (15 lbs)
1.6 kg (3.5 lbs)
4 kg (9 lbs)
Weight
Expansion via TCP/IP
The NET expansion is a fantastic way to combine two or more D310 instruments to one multichannel system. Each
instrument must have the hardware option UP-ORION-SYNC and the software option DS-OPT-NET. Synchronization of
all units is required too. There are two synchronization methods: (1) a simple SYNC cable connection, for distances
up to 200 m, or (2) DEWE-CLOCK (internal or external), for long distances when a SYNC cable connection is not
possible. The DS-OPT-NET software offers full remote setup, online data transfer up to the limit of the network
connection and offline data transfer between the
instruments.
0.000 ms
User tip: The NET expansion allows multiple usages
of the PC power and fast storing capability. Multiple
decentralized hard disks offer almost no limit for fast
data storing.
GPS-CLOCK
SYNC
D310
D310
DEWE-CLOCK
D310
SYNC
ETHERNE
10
ETHER
D310
T
NET
SYNC
www.de wam eri ca .com/ D310
PCI
AC (optional DC)
D310
power supply
expansion
The PCI expansion is an alternative especially if high channel count is
needed. When using an expansion only one PCI slot is occupied in the
D310 instrument by a PCI-HOST-CARD. The DEWE-50, DEWE-51 and
DEWE-52 ADC racks can be connected by a 1m PCI cable. The ORION
cards are installed inside the DEWE-5x unit and you simply have to
select the suitable signal amplifiers for your needs.
Important notice: The D310 and the DEWE-5x must be equipped with
ORION-SYNC option.
PCI H
OST
SY N C
User tip: with an additional ECARD-34 or 54 the DEWE-5x also can
be used as an independent system in combination with a laptop
computer.
PORTABLE SIDEHAND / D310 SERIES
DEWE-52-PCI-3216
Specifications
DEWE-50-PCI-32
DEWE-50-PCI-64
DEWE-51-PCI-64
DEWE-51-PCI-128
DEWE-52-PCI-3216
DAQ/PAD/HSI slots
32
64
--
--
16
MDAQ channels
--
--
64
128
32
Power supply
95 ~ 260VAC / 50/60 Hz
Optional power supply
Dimensions W x D x H
Weight
Wide range DC power (11 to 32 VDC)
435 x 287 x 223 mm
17.1 x 11.3 x 8.8 in.
408 x 287 x 410 mm
16.1 x 11.3 x 16.1 in
435 x 287 x 178 mm
17.1 x 11.3 x 7.0 in.
408 x 287 x 267 mm
16 x 11.3 x 10.5 in.
435 x 287 x 223mm
17.1 x 11.3 x 8.8 in.
10 kg (22 lbs)
15 kg (33 lbs)
6 kg (13 lbs)
9 kg (20 lbs)
9 kg (20 lbs)
Dewetron HSI series Signal Conditioners
MODULE
INPUT TYPE
RANGES
TEDS
BANDWIDTH
(BW)
FILTERS (LP / HP)
ISOLATION (ISO)
OVER-VOLTAGE PROTECTION (OP)
High Voltage Measurement
HSI-HV
V
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
BW: 2 MHz
LP: 10, 30, 100,
300 Hz
1, 3, 10, 30, 100,
300 kHz
1, 2 MHz
ISO: 1.8 kVrms
(line-to-line)
Yes
(DSUB
and
LEMO
versions
only)
BW: 2 MHz
LP: 10, 30, 100,
300 Hz
1, 3, 10, 30, 100,
300 kHz
1, 2 MHz
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
Yes
BW: 2 MHz
LP: 10, 30, 100,
300 Hz
1, 3, 10, 30, 100,
300 kHz
1 MHz
ISO: 350 VDC
OP: ±10 VDC
Low/Medium Voltage & Current Measurement
HSI-LV
V
Voltage, current with
external shunt or current
sensor
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
IEPE via MSI-V-ACC
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
-200 to 1000 C and 0 to 6.5 kΩ
Strain gages, bridge sensors, voltages
Bridge: full, half, quarter
Voltage: Up to ±10V
Pot./Ohmic sensors
Resistance/Ω: up to 10 kΩ
Thermocouple via MSRBR-TH series
J, K, T and C types
Bridge / Strain Gage Measurement
HSI-STG
11
PORTABLE SIDEHAND SERIES
Dewetron DAQ series Signal Conditioners
MODULE
INPUT TYPE
RANGES
TEDS
BANDWIDTH (BW)
FILTERS (LP / HP)
ISOLATION (ISO)
OVER-VOLTAGE PROTECTION (OP)
High Voltage Measurement
DAQP-HV
V
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.8 kVrms (lineto-line)
High voltage
±20, ±50, ±100, ±200, ±400, ±800,
±1400 V
N/A
BW: 700 kHz
ISO: 1.8 kVrms (lineto-line)
High voltage
±10, ±40, ±100, ±200, ±400, ±1000 V
N/A
BW: 20/30 kHz
LP: 10, 100, Hz
1, 2, 20/30 kHz
ISO: 1.5 kVrms
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: up to 1 kVrms
(with banana jacks)
OP: 350 VDC
DAQP-HV-S3
V
DAQP-DMM
V
Low/Medium Voltage & Current Measurement
DAQP-LV
V
DAQP-V
V
Voltage, current with
external shunt or current
sensor
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
IEPE via MSI-V-ACC
±10, ±20, ±50, ±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10 V
PT100, Pt200, Pt500,
Pt1000, Pt2000 and resistance via MSI-V-RTD
-200 to 1000 C and 0 to 6.5 kΩ
Voltage, current with
external shunt or current
sensor
±10, ±100 mV
±1, ±5, ±10, ±50 V
N/A
BW: 50 kHz
LP: 10, 100 Hz
1, 10, 50 kHz
ISO: up to 1 kVrms
OP: ±500 VDC or 350
Vrms
Current
Note: 5Arms continuous
±0.1, ±0.3, ±1, ±3 A
±10 A peak, ±30 A peak
max 5Arms continuous current
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVrms
Current
Note: intended for 4-20
mA applications
±2, ±6, ±20 mA
±60 mA, ±200 mA, ±0.6A
max 0.6 A
N/A
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVrms
Strain gages, bridge sensors, voltages
Bridge:full, half, quarter bridge
Voltage: up to ±10 V
Pot./Ohmic sensors
Resistance/Ω: up to 10 kΩ
ISO: 350 VDC
OP: ±10 VDC
Thermocouple via MSRBR-TH series
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
J, K, T and C types
Strain gages, bridge
sensors
±1, ±2, ±5, ±10, ±20, ±50 mV/V
(@ 5 Vdc excitation)
Pot./Ohmic sensors
200 Ω to 10 kΩ
N/A
ISO: 350 VDC
OP: ±50 VDC
Thermocouple via MSRBR-TH series
BW: 20 kHz
LP: 10, 100 Hz
1, 5, 20 kHz
Full range of thermocouple type
Strain gages, bridge
sensors
±0.1, ±0.2, ±0.5, ±1, ±2, ±5, ±10,
±20, ±50, ±100 mV/V
(@ 5 Vdc excitation)
Yes
BW: 200 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 200 kHz
ISO: N/A
OP: ±10 VDC
N/A
BW: dc to 2.3 kHz
LP: 10, 30, 100, 300 Hz
1 kHz
ISO: N/A
OP: ±10 VDC
DAQP-LA-SC
DAQP-LA-B
Bridge / Strain Gage Measurement
DAQP-STG
DAQP-BRIDGE-A
DAQP-BRIDGE-B
DAQP-CFB
12
Pot./Ohmic sensors
200 Ω to 10 kΩ
Thermocouple via MSRBR-TH series
Full range of thermocouple type
AC bridge, strain gage,
carrier sensors
Bridge: 0.1 to 1000 mV/V
Inductive: 5 to 1000 mV/V
Inductive/ LVDT sensors
Voltage: 0.2 to 1000 mV/vrms
www.de wam eri ca .com/ D310
MODULE
INPUT TYPE
RANGES
TEDS
BANDWIDTH (BW)
FILTERS (LP / HP)
ISOLATION (ISO)
OVER-VOLTAGE PROTECTION (OP)
Charge/IEPE Measurement
DAQP-ACC-A
DAQP-CHARGE-A
±50, ±166, ±500 mV; ±1.66, ±5 V
(Gain: 1, 3, 10, 30, 100)
IEPE and charge sensors
Note: selectable
integration and double
integration
Charge: 5, 50, 500, 5000, 50000 pC
IEPE: ±5, ±50, ±500 mV, ±5 V
(0, 20, 40, 60 dB)
Charge sensors
Note: selectable time
constant for static charge
sensors
±100, ±500, ±2 000, ±10 000,
±40 000, ±200 000, ±1 000 000 pC
Thermocouple (universal)
K, J, T, R, S, N, E, B, L, C, U type,
internal linearization, freely programmable range, internal CJC
RTD
Pt100, Pt200, Pt500, Pt1000 and
Pt2000 sensors, programmable range
(2-wire and 4-wire only)
Yes
BW: 0.5 Hz to 300 kHz
LP: 1, 10, 100, 300 kHz
HP: 0.5 Hz, 5 Hz
N/A
N/A
BW: 0.1 Hz to 50 kHz
LP: 100 Hz; 1, 3, 10, 50
kHz
HP: 0.1 Hz, 1 Hz, 10 Hz
N/A
N/A
BW: 0.5 Hz to 100 kHz
LP: 10, 30, 100, 300 Hz;
1, 3, 10, 30, 100 kHz
HP: DC, 0.0001 Hz to
0.5 Hz
ISO: 350 VDC
Yes
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
programmable
ISO: 1000 Vrms
continuous (for input,
excitation and TEDS
interface)
ISO: ±1000 Vrms
continuous
PORTABLE SIDEHAND / D310 SERIES
DAQP-CHARGE-B
IEPE sensors
Temperature and Universal Measurement
DAQP-MULTI
V
Voltage
10 ranges from ±5 mV to ± 5 V
Resistance
freely programmable range from 1
Ohm to 1 MOhm
Bridge (constant current)
4-wire full bridge sensors, 13 ranges
from ±0.5 to 5000 mV/mA
Thermocouple (universal)
K, J, T, R, S, N, E, B, L, C, U
freely programmable within the
maximum range of the selected thermocouple type, internal linearization,
internal CJC
N/A
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
(programmable)
Frequency to voltage
100, 1k, 5k, 20k, 100k and 200 kHz
ranges;
Trigger level range 0 to 130 V,
Additional TTL output (isolated pulse
output of input signal)
N/A
BW: 200 kHz
Selectable input and output
filters (range-dependent)
ISO: 350 VRMS
Analog output
1:1 output module, from 0 to ±10 V
Accuracy ±0.05 %
Connector choices: banana, BNC, or
9-pin DSUB connector
N/A
BW: 400 Hz
ISO: CMV output to
input, continuous: 1500
VRMS max
DAQP-THERM
Frequency to Voltage Measurement
DAQP-FREQ-A
Output Modules
DAQN-V-OUT
OUT
13
PORTABLE SIDEHAND SERIES
MDAQ Series Amplifiers
Multi channel
Small form factor for high channel density
Cost effective
High bandwidth up to 300 kHz
SUB Modules for MDAQ-BASE-x
Module
MDAQ-SUB-STG-D
Connector: DB-9
# CH Input type
8
V
MDAQ-SUB-BRIDGE-D
Connector: DB-9
8
V
MDAQ-SUB-V-200-D
Connector: DB-9
TEDS
Bandwidth (BW),
Excitation
Highpass filters (HP)
■
BW: 30 kHz
0 to 12 VDC
■
BW: 30 kHz
HP: 0.16 Hz
+15 VDC and
0 to 12 VDC
■
BW: 300 kHz
±15 VDC and
0 to 12 VDC
-
BW: 300 kHz
-
■
BW: 300 kHz
HP: 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
* Voltage up to ±200 V:
* ICP, via MSI-V-ACC:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-V-RTD:
Note:
for safety reasons, max. 120 V DC or 50 V AC
13 ranges from ±0.125 to ±200 V
7 ranges from ±0.25 mV to ±10 V
-200 °C to 1000 °C
and 0 to 6.5 kOhm
8
* Voltage up to ±200 V:
13 ranges from ±0.125 to ±200 V
are allowed at this connector
Note:
for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector
V
MDAQ-SUB-ACC-BNC
Connector: BNC
* Strain-gage (Full-, and half bridge)
for strain gage sensors:
* Voltage up to ±10 V:
* ICP, via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
8
V
MDAQ-SUB-V-200-BNC
Connector: BNC
* Strain-gage (Full-, half and quarterbridge, incl. shunt calibration)
for strain gage application:
* Voltage up to ±10 V:
* ICP via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
Input ranges
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended or differential input and one highpass filter
3.4 Hz highpass filter for noise and shock response measurement
MDAQ-SUB-ACC-BNC-S1
0,16 Hz for structural and modal analysis, human body vibration measurement
(rest same as MDAQ-SUB-ACC-BNC)
MDAQ-SUB-ACC-A-BNC
Connector: BNC
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input and two HP filters
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
MDAQ-SUB-ACC-A-MD
Connector: Microdot
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input, two HP filters and sensor failure detection
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
Option: test signal input for all channels
14
www.de wam eri ca .com/ D310
Filter modules for MDAQ
# CH
16
Filter characteristics
Butterworth
Cut-off frequencies
100 Hz, 1, 10, 30, 100 kHz, Bypass
Order
th
4
PORTABLE SIDEHAND / D310 SERIES
Module
MDAQ-AAF4-5-BU
Note:
not possible in all system configurations.
Please contact factory for details.
nd
MDAQ-FILT-5-BU
16
Butterworth
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
MDAQ-FILT-5-BU-S1
16
Butterworth
100 Hz, 1, 10, 30, 100 kHz, Bypass
2
MDAQ-FILT-5-BE
16
Bessel
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
nd
nd
Modular smart interfaces to connect various sensors
MSI interfaces
MSI-BR-V-200
Differential voltage adapter, for voltages up to +/-200V.
BNC connector.
TEDS for automatic MSI indentification.
MSI-BR-RTD
Pt100, Pt200, Pt500, Pt1000, and Pt2000 adapter, for RTD sensors. 5-pin BINDER 710 series input connector. RTD power is provided. 2, 3,
and 4 wire connection methods supported.
TEDS for automatic MSI indentification.
MSI-BR-ACC
Isotron / IEPE (constant current) conditioner for IEPE accelerometers and microphones. Excitation current 4 mA at 21 VDC, 1.5 Hz high-pass
filter, BNC connector.
TEDS for automatic MSI indentification.
MSI-BR-CHA-50
Adapter for dynamic charge sensors, range up to 50000 pC, AC coupled with 0.07 Hz, max. 100 kHz bandwidth (or limited to the max. bandwidth of the input that it is plugged into). BNC connector.
TEDS for automatic MSI indentification.
MSI-BR-TH-K
Thermocouple adapter, type K, high accuracy cold junction reference built-in.
1 m long thermocouple cable with Mini TC connector.
Isolated thermocouple sensors highly recommended for low-noise performance.
TEDS for automatic MSI indentification.
MSI-BR-TH-J
Same as MSI-BR-TH-K except for type J sensors.
MSI-BR-TH-T
Same as MSI-BR-TH-K except for type T sensors.
15
PORTABLE SIDEHAND SERIES
DEWETRON “D SERIES” INSTRUMENTS
Our “D series” instruments combine data acquisition excelence with an affordable price point. Choose
from among these basic models:
D3PC - Smallest mainframe system, capable of 8 x IEPE /low voltage inputs
D310 - Smallest "all in one" D series instrument, with optional display and battery backup
D410 - Twice to number of possible channels as the D310, but not twice as big!
D510 - Benchtop and Rackmounting "convertible" unit, capable of up to 96 fast channels
D3PC series
8 fast channels
8 or 16 channels
2 counters
15" touchscreen
(optional)
8 DI/O channels
Attachable UPS
option
DC powered
8 IEPE inputs
DAQ/HSI or MDAQ
conditioners
Made in USA
Made in USA
D410 series
D510 series
16 to 32 channels
Touchscreen
display
Convenient form
factor
DAQ/HSI or MDAQ
conditioners
16 to 128 channels
DAQ or MDAQ
conditioners
Benchtop or rackmounting conversion
within 5 minutes
Made in USA
Service with a Smile!
When you build something, you have to support it. If it’s an instrument, then you also need to be able
to calibrate it according to NIST and ANSI Z540 standards. This is exactly what we can do for you,
both in America and in Europe, using our modern Fluke Met/CAL® automated calibration procedures.
We have comprehensive service and support facilities around the globe, ready to support our customers, which are increasingly global in nature. We stand behind our products, which means that we stand
behind you. If you additionally require ISO/IEC 17025 certified calibration we can provide that, too.
We are proud of our products, and we are ready, willing, and able to support them 100%, to ensure
your satisfaction and continued patronage. Won’t you give us a try, and find out for yourself about the
Dewetron difference?
DEWETRON, INC. • 10 High Street, Ste K • Wakefield•RI•02879•USA
Tel (+1) 401-284-3750 • Fax (+1) 401-284-3755 • [email protected]
Printing version 7/5/2014
16
All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © 2013 DEWETRON, INC
D310 series
www.de wam eri ca .com/ D310