OptimEyes Smart Products 2.0 for Cataract Surgery

Transcription

OptimEyes Smart Products 2.0 for Cataract Surgery
Integrated Scientific Services
Optimeyes
Using Advanced Non-linear FEM
Models for Patient Specific
Modelling of Eye Laser Surgery
Harald Studer, PhD
Team leader Optimeyes™
ISS AG
[email protected]
Thierry Marchal
Industry Director, Healthcare
ANSYS, Inc.
[email protected]
Integrated Scientific Services
Optimeyes
Motivations
• Patient specific
• Safer surgery planning
• Reduction of cost of Medical Devices &
Services
Integrated Scientific Services
Optimeyes
The Role of ANSYS
• Best in Class FEM technology combined with the widest range
of CAE software portfolio
• Large network of partners,
including in the medical and
clinical world
• Clear demand from the clinical
community to take advantage
of simulation
• Joining force with clinical
experts towards vertical
clinical applications
“I don’t understand why simulation is used so much
in automotive and aeronautic applications and so
little in the medical world, where we directly impact
a patient’s life. As surgeons, we are spending years to
acquire enough know-how and experience to learn how to
react quickly when the patient is lying on the operating
table; but simulation is giving us the luxury to examine the
situation when we still have plenty of time to think through
more quietly. I trust that simulation will be used
increasingly in the clinical world in the near future.”
Dr. Antoine Lucas
Cardiovascular Surgeon
University Hospital of Rennes
Source: ANSYS Healthcare blog
Integrated Scientific Services
Optimeyes
Retina
Crystalline lens
Cornea
Iris
Optic nerve
Musculi recti
Integrated Scientific Services
Optimeyes
60%
IOP
Integrated Scientific Services
Optimeyes
Integrated Scientific Services
Optimeyes
Refractive Surgery
•
•
•
•
•
•
•
Arcuate Keratotomy
Limbal Relaxing Incisions
Cataract Surgery
Laser In-Situ Keratomileusis
Photo Refractive Keratectomy
Deep Lamelar Keratoplasty
Penetrating Keratoplasty
• Automated Lamelar Keratoplasty
• Laser Assisted Sub-Epithelium
Keratomileusis
• Laser Assisted In-Situ Keratomileusis
• Radial Keratotomy
• Thermal Keratoplasty
• Intrastromal Corneal Ring Segments
Integrated Scientific Services
Optimeyes
Refractive Surgery
• Arcuate Keratotomy
• Cataract Surgery
• Laser Assisted In-Situ Keratomileusis
Integrated Scientific Services
Optimeyes
flat axis (Kf)
steep
axis (Ks)
• Arcuate Keratotomy
Zone [mm]
Nbr
45° [D]
60° [D]
90° [D]
7
1
1.00
1.50
2.00
7
2
2.00
2.25
4.00
6
1
1.50
3.00
3.00
6
2
3.00
4.50
6.00
Integrated Scientific Services
Optimeyes
Refractive Surgery
• Arcuate Keratotomy
• Cataract Surgery
• Laser Assisted In-Situ Keratomileusis
Integrated Scientific Services
Optimeyes
• Cataract Surgery
Integrated Scientific Services
Optimeyes
Refractive Surgery
• Arcuate Keratotomy
• Cataract Surgery
• Laser Assisted In-Situ Keratomileusis
Integrated Scientific Services
Optimeyes
• Laser Assisted In-Situ Keratomileusis
Integrated Scientific Services
Optimeyes
Statistics / Experience
Planning
Surgery
Integrated Scientific Services
Optimeyes
Refractive Outcome
(Refractive Accuracy a Huge Issue for Private Pay Segment – Bill Freeman)
< 0.5D
0.5D-1.0D
1.0D-1.5D
1.5D-2.0D
>2.0D
Source: ASCRS Study with more than
9000 patients in 1996
Statistics / Experience
Planning
Surgery
Integrated Scientific Services
Optimeyes
Already highly precise
Statistics / Experience
Planning
Surgery
Integrated Scientific Services
Optimeyes
Can we provide patient-specific surgery planning aid?
Statistics / Experience
Planning
Surgery
Integrated Scientific Services
Optimeyes
Material law
Validation
Surgery
simulation
Application
Integrated Scientific Services
Optimeyes
Material law
Validation
Y = U[J]+
Y[C]+
Surgery
ò
p
1
p
0
(
Tissuesimulation
features modeled:
•
•
•
•
)
F ( R, j;q ) Y f 1[C, A]+ Y f 2 [C, B] dq
Incompressibility
Isotropic tissue matrix (Proteoglycans, GAGs, …)
Collagen fibers with realistic distribution (x-ray scattering investigations)
Collagen cross-links Application
Integrated Scientific Services
Optimeyes
Simulation:
Material law
• Finite element (FE) model
Validation
Surgery
simulation
Application
• Patient-specific model
• Mesh-warping
Integrated Scientific Services
Optimeyes
Clinical validation:
• Prospective clinical study
• 13 Patients
• 1 month follow-up
Surgery
simulation
Application
Material law
Validation
Integrated Scientific Services
Optimeyes
Where our technology helps:
• R&D (new products)
• Daily clinical practice
• Embedded in surgical devices
• …
Surgery
simulation
Application
Material law
Validation
Integrated Scientific Services
Optimeyes
Clinics
Industry
 Technology transfer
Integrated Scientific Services
Optimeyes
Integrated Scientific Services
Optimeyes
Take-home message:
Academic results from numerical simulations and
biomechanical models can be applied in the
industry and daily clinical practice!
A close collaboration between ANSYS,
its partners and clinicians will make our
lives so much better.
Integrated Scientific Services
Optimeyes
Thank you..