Vandal Resistant Bollard - Concrete Shaft VRB1C

Transcription

Vandal Resistant Bollard - Concrete Shaft VRB1C
VRB2C &
VRB4C
Dual Function
P.O. Box 1275 • 16555 East Gale Ave.
City of Industry, California 91749-1275
626/968-5666 • FAX 626/330-3861
Vandal Resistant Bollard - Concrete Shaft
VRB1C Installation Instructions
!
VRB1C &
VRB3C
Single Function
VRBC
Unlighted
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
Failure to do so may result in serious personal injury.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, globe must be kept clean and free of
dirt, dust, leaves, and trash. Globe should be regularly cleaned with a solution of ammonia and water or a suitable
glass cleaner.
NOTE: All electrical work must be done by a qualified electrician. KEEP THIS SHEET FOR FUTURE REFERENCE.
ATTENTION: If your fixture is equipped with a multi-tap ballast and if no voltage was specified on the purchase order,
the ballast has been wired for operation on a 277 volt circuit (347V in Canada). If other than 277 volts is required, i.e.;
120V, 208V, 240V, connect incoming voltage lead to required voltage lead on terminal block.
Tools Required:
B" Allen wrench
5/32"
Allen Wrench
Concrete Installation Instructions:
!
1. To protect finish, lay concrete
bollard horizontally on wood
blocks.
2. Install the four anchor plates with
four D-11 hex head bolts
provided. Position the anchor
plates straight from center on
round bollards (see Plan View).
Optional
Expansion
Joint
Grade
Typical
Installation In
Concrete
Revised 06/26/12
Make certain the electrical supply is OFF before starting installation.
Grouting
Note: Cover All Exposed
Metal Mounting Hardware
Concrete
I” Wrench
G" Wrench
3. Route field wires through and out
top of bollard. Concrete bollards
are heavy. Use adequate means
to lift bollard and set onto anchor
bolts without dropping. Install flat
washers & K" nuts.
PLAN VIEW
Orientation
Line
4. Make final adjustments to level bollard by
turning the bottom nuts on the anchor
bolts. Secure bollard by tightening the top
nuts on the anchor bolts. The bollard must
have full contact with concrete foundation
by grouting. Mounting hardware must not
Conduit
(By Others) be in contact with soil or other corrosive
elements. If luminaires will not be
Typical
immediately installed on lighted bollards,
Installation In
cover top of bollard so water or debris will
Earth
not collect inside.
EC 120626005
Status 9
Concrete Bollard
Anchor Plate
Part No. 95474
VRB1C - Concrete Shaft Installation Instructions
FIXTURE / BALLAST INSTALLATION INSTRUCTIONS:
! Make certain the electrical supply is OFF before starting fixture installation.
Mounting Rods
(4 Places)
Fixture Mounting Screws (4) C”-16 x 1K” Long Round Head
Gasket
J-20 Nuts (6)
Ballast Assembly
Stacked Louvers
Gasket
Mounting
Plate
Terminal
Block
Ty-Rap
Connect incoming voltage lead to required voltage lead on terminal block.
(Supplied on a multi-tap ballast)
1. a. Mount ballast assembly onto fixture as shown.
b. Make connections as per wiring diagram shown on ballast.
c. Remove fixture top. Note: Fixture top screws need only to be loosened. Turn top to open area in keyhole slot
and lift off.
d. Remove six J-20 nuts and lift off stackable louvers.
Install Mounting Rods
(4 places)
Mounting Plate
Gasket
2. Place gasket on top of bollard. Route field wires
through ty-rap (strain-relief) and make wiring
connections to terminal block, i.e.; green-to-ground,
white-to-common, and black-to-voltage.
3. Install mounting plate/ballast assembly onto bollard
making sure that none of the wires are pinched.
Secure mounting plate with screws provided.
Install mounting rods in the two spaces provided.
Note: For incandescent fixtures, connect the lamp leads
directly to the field wires - No Ballast Required.
4. Install the stackable louvers onto the mounting rods and secure. Install lamp of type and wattage shown on fixture
label. Replace retaining strap and pressure pad. Replace top.
Page 2
Kim Lighting • P.O. Box 60080 • 16555 E. Gale Ave. • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-8361
VRB1C - Concrete Shaft Installation Instructions
LAMP INSTALLATION OR REPLACEMENT INSTRUCTIONS:
! Make certain electrical supply is OFF before starting installation or replacement.
Button Head
Screw
Top Cap
Retaining Strap
& Pad
Stackable
Louvers
1. Locate two J-20 button head top cap screws
(180° apart) concealed under top cap. Feel for
screw heads approximately L” up under top cap
between vertical ribs. The screw heads are only
visible from low angles near the fiture body.
Loosen - do not remove - screws with a standard
5/32” Allen wrench. Turn top cap clockwise and lift
up to remove.
2. Remove J-20 hex nut securing one end of globe
retaining strap. Loosen the other hex nut and
pivot retaining strap to side. Lift globe up to
remove.
3. Install lamp of type and wattage shown on fixture
label. Make sure globe gasket surface is clean
then reinstall globe.
4. Replace top cap by aligning screws with keyhole
slot openings. Turn top cap counter clockwise
and tighten screws.
WARNING:
The H.I.D. / Fluorescent fixture utilizes a lamp that
may contain mercury. For information on disposal
of lamp go to website:
www.lamprecycle.org
Page 3
! MAINTENANCE WARNING:
To maintain light efficiency and prevent fixture
overheating, globe must be kept clean and free of
dirt, dust, leaves and trash. Globe should be
regularly cleaned with a solution of ammonia and
water or a suitable glass cleaner.
Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
VRB1C - Concrete Shaft Installation Instructions
KIM LIGHTING LIMITED WARRANTY
When installed in accordance with Kim Installation Instructions and accepted trade practices, the
following shall apply:
General Product Limited Warranty Coverage
All material and component parts used in the manufacture of Kim Products, are warranted to be
free from defects of material and/or workmanship for a period of 1 year from date of sale, with the
following exceptions:
Auxiliary Equipment
All auxiliary equipment (such as lamps, ballasts, and transformers) provided by and/or included in
Kim Products shall carry the component manufacturer's warranty.
Copper and Bronze Landscape Components
Copper and Bronze Landscape fixture components shall be warranted against defects of material
and/or workmanship, and failure due to corrosion, for a period of 25 years from date of sale.
Composite In-Grade Components
Composite In-Grade fixture components installed below grade, shall be warranted against defects
of material and/or workmanship, and failure due to corrosion, for a period of 7 years from date of
sale.
Aluminum Landscape Components
Aluminum Landscape fixture components not in direct contact with soil, shall be warranted against
defects of material and/or workmanship for a period of 3 years from date of sale. Aluminum fixture
components in direct contact with soil shall be warranted from defects of material and failure from
corrosion for a period of 1 year from date of sale.
Limit of Liability and General Conditions
Only products which are installed, used and maintained in accordance with applicable Kim
instructions, specifications and accepted trade practices, are covered by the Kim Warranty.
During the warranty period, with proof of purchase, Kim will repair or replace with the same or
similar product, at Kim's option, without charge. Labor costs are the owner's responsibility and are
excluded from this warranty. This warranty is void if the product is modified, tampered with,
misapplied, poorly installed, improperly maintained, or subjected to abnormal conditions.
Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser.
This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty
of fitness for a particular application. Kim Lighting shall not be liable to the purchaser for indirect or
consequential damages.
How may we serve you better?
Please let us know. Visit our website at:
www.kimlighting.com
Your concerns are important to us.
Page 4
Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861