Untitled - MBTA.com

Transcription

Untitled - MBTA.com
ITEM
NUMBER
QUANTITY
DESCRIPTION
M101
AUXILIARY DRIVE
GEARMOTOR W/BRAKE
3
(INCLUDES 1 SPARE)
SEW EURODRIVE R107 DRE180M4 BE20HR;
20 HP, RATIO 27.58:1, 64 RPM OUTPUT
M102
DISCONNECT COUPLING
2
M103
PINION SHAFT BEARINGS
6
(INCLUDES 2 SPARES)
M104
BEARING SUPPORTS
ITEM
4
FALK 1025 G72, WITH CUSTOM SHIFTER
ASSEMBLY
DODGE DOUBLE-INTERLOCK 4-BOLT BASE, 3
FIXED, 3 EXPANSION (INCLUDES 1 FIXED
SPARE, 1 FLOAT SPARE)
ASTM A588 WELDMENT
2 - EAST SPAN (INCLUDES 1 SPARE)
2 - WEST SPAN (INCLUDES 1 SPARE)
ASTM A291, CL. D
4
(INCLUDES 2 SPARES)
ASTM A291, CL. D
M105
PINION SHAFT
M106
PINION
M107
MOTOR SUPPORT
2
M108
ANGLE INDICATOR
4
ASTM A588 WELDMENT
REIKER INC., BOOM ANGLE INDICATOR,
MODEL NO. 4120WBL (SEE CONTRACT
SPECIFICATIONS FOR PLACEMENT DETAILS)
EQUIPMENT LIST
PIECE
NO.
QUANTITY
NAME
E101
1
DOUBLE
THROW
SAFETY
SWITCH
EATON
-
E102
2
AUXILARY
DRIVE CABINET
HAMMOND
ECLIPSE SERIES
NEMA 4X, 316 STAINLESS STEEL, DISCONNECT ENCLOSURE, CONTINOUS HINGE,
SIZED APPROPRIATLY FOR ALL DEVICES NEEDED.
E103
2
TRACK LEVEL
PUSHBUTTON
STATION
HAMMOND
1435SS SERIES
THREE BUTTON, NEMA 4X, 316 STAINLESS STEEL ENCLOSURE, SIZED APPRORIATLY
FOR ALL DEVICES NEEDED.
E104
2
SOFT STARTER
ALLEN BRADLEY
SMC-3
SOFT STARTER, UL LISTED, 480VAC, SCR CONTROLLED, 43 CONTINOUS AMPERES,
MULTIPLE MODES OF OPERATION, BUILT IN MOTOR OVERLOAD PROTECTION
E105
1
JUNCTION BOX
HAMMOND
1418N4SS SERIES
NEMA 4X, 316 STAINLESS STEEL, JUNCTION BOX ENCLOSURE, CONTINOUS HINGE,
INTERIOR REAR PANEL, SIZED APPROPRIATLY FOR ALL CONDUCTORS NEEDED.
E106
2
E107
2
E108
1
CIRCUIT
BREAKER AND
ENCLOSURE
EATON
CUTLER-HAMMER
E109
1
TOWER A
INTERFACE
CABINET
HAMMOND
1418J SERIES
MANUFACTURER
COUPLING
EATON
LIMIT SWITCH
REMOTE
WIRELESS
OMNEX CONTROLS
CONTROL
SYSTEMS
TYPE-MODEL
E50
R160 AND T150
RATING AND DESCRIPTION
HEAVY DUTY DOUBLE THROW, 600VAC, 100A RATED, 4 POLE SWITCHED NEUTRAL
SAFETY SWITCH, NEMA 3R RATED, UL LISTED, 100A CAPACITY. ENCLOSURE SHALL
INCLUDE EXTERNAL GENERATOR HOOK-UP RECEPTACLES.
UL LISTED, NEMA 4X, CONTACTS RATED 10 AMPS CONTINUOUS, TWO POLE, WITH
ADJUSTABLE ROLLER TRIP ARM.
PORTABLE, LONG RANGE, PROGRAMMABLE RADIO REMOTE CONTROL SYSTEM. FCC
APPROVED, 900MHz or 2.4GHz, 24VDC, WEATHER PROOF. TRANSMITTER WITH
E-STOP AND VARIOUS SWITCHES PROGRAMMED PER SPECIFICATIONS.
UL LISTED ENCLOSURE AND UL LISTED MOTOR PROTECTION CIRCUIT BREAKER,
ENCLOSURE RATED NEMA 12, TO BE LOCATED IN TOWER A, ENCLOSURE TO BE
RATED AND INSTALLED AS SHOWN ON DRAWINGS.
ENCLOSURE IS TO HOUSE THE EQUIPMENT FOR MAIN MOTOR INTERUPT CIRCUITRY,
ENCLOSURE IS TO BE UL LISTED AND RATED NEMA 12 AND LOCATED IN TOWER A
ELECTRICAL ROOM.