MeriCheck A1c-CRP.cdr
Transcription
MeriCheck A1c-CRP.cdr
TM TM TM TM TM TM Meril Diagnostics Emerging from a lineage of successful business enterprise, Meril Diagnostics is an in-vitro diagnostic arm of the multi million dollar group MNC. Meril Diagnostic’s core objective is to design, manufacture and distribute, clinically relevant, state of the art and best in class analyzers and reagents to alleviate human suffering and improve Quality of Life. Corporate Office Meril Training Academy While innovations and advancements play a vital role in contributing towards better health of the society, a larger role also lies in educating and imparting training to pathologists, clinicians, technicians and other members of the medical fraternity. Meril's corporate office sits proud ensconced within the serene hill sides of Chala town; located 150 kms north of Mumbai at Vapi Manufacturing Meril's Training Academy is a world class, first of its kind institution that offers both practicing professionals and students hands on training and knowledge. 300,000 sq feet state of the art manufacturing, research and development facility located at Vapi for Diagnostics, Orthopaedics, Endo-surgery equipments and Cardiovascular, comprising a team of designers, engineers, chemists, microbiologists and R&D scientists. Modernistic, contemporary academy with Hands on Trainings, Simulators, Live Case Learning, Distance learning, Hard-ware play rooms, Libraries, Cadaver and Animal models. Boronate Affinity (POCT) High quality Boronate Affinity (HbA1c) and sandwich immunoassay (CRP) principle Results available in 7sec 3.5 inch Graphic Color Touch LCD Sample type - Whole blood (Capillary and Venous), Serum, Plasma (CRP test) Sample volume - 5 µl Automatic Tray loading Maximum of 300 test results can be saved in the memory space Built-in Thermal printer Optional Barcode reader USB, RS-232 Interfacing Voice guide and instruction 5 µl Tiny drop of blood using capillary tube 7sec. Immediate results available within 7 sec. (Total Assay Time : 3 min.) Mericheck A1c/CRP analyzer is an in-vitro diagnostic, POC device with high performance that uses a Boronate Affinity principle for HbA1c testing and sandwich immunoassay principle to test CRP; a sensitive marker of inflammation. Principle Glycated haemoglobins (GHb) and glycated plasma proteins (GPP) differ from non-glycated proteins by the attachment of a sugar moiety(s) at various binding sites by means of a ketoamine bond. GHb and GPP thus contain 1,2-cis-diol groups not found in non-glycated proteins, which provide the basis for separation of glycated and nonglycated components by boronate affinity chromatography. Ease of Operation is integrated with Auto Guide Operation and with Automatic tray feeding to ensure ease of operation. Sampling Sample type- Whole blood (Capillary and Venous), Serum, Plasma (CRP test) Sample volume- 5 µl In case of CRP testing, on the test well of the device there is a membrane coated with immobilized CRP-specific monoclonal antibodies. A diluted sample is applied to the test device. When the sample flows through the membrane, the CRP are captured by the antibodies. CRP trapped on the membrane will then bind the goldantibody conjugate added, in a sandwich-type reaction. Unbound conjugate is removed from the membrane by the washing solution. A paper layer underneath the membrane absorbs excess liquid. In the presence of a pathological level of CRP in the sample, the membrane appears redpurple with color intensity proportional to the CRP concentration of the sample. incorporates both USB and RS232 interface to connect the instrument with the computer. Display This makes sure that the instrument can be connected, no matter which interfaces are installed. Fast and reliable has short result measuring time with immediate results available within 7 seconds. Total assay time is of 180 seconds. Memory has storage capacity of 300 test results. Connectivity user friendly software enables operator to program protocols with ease using 3.5 inch graphic user interface (GUI) colour touch LCD. Built in printer is integrated with thermal printer to print the respective results of HBA1c and CRP. Measuring Principle Boronate Affinity (A1c) & Sandwich immunoassay (CRP) Total Assay Time < 180 sec Measurement time 7 sec Measurement range 4 -15% (A1c) Sample Volume 5 µl Sample Type Whole blood (Capillary and Venous), Serum, Plasma (CRP test) Display 3.5 inch Graphic Color Touch LCD Memory 300 Test Results Printer In-built thermal printer External interface USB : Use for upgrading the firmware RS-232 : Use for Barcode Reader Input Voltage (DC) + 12 V, Dedicated AC adaptor Electricity Consumption 12W(Max) Main Adapter Separate AC to DC mains adapter Input 100 ~ 240V Output 12V / 2A Operating Temperature 5 ~ 35°C / 59 ~ 95°F Relative Humidity 15 ~ 75% RH Altitude 3,000m(Max) Storage Temperature 10 ~ 60°C / 14 ~ 140°F Dimensions 178 mm (W) x 195 mm (L) x 75 mm (H) Weight Approx. 730g TM TM TM HbA1c Kit (POCT) 30 Tests MCKCRP-01 CRP Kit (POCT) 30 Tests TM TM TM D1 - D3, Survey No. 135/2/B & 174/2, Meril Park, Muktanand Marg, Chala, Vapi - 396191, Gujarat, India. +91 22 30732400 Tuzla MAC|BROCHURE|20140530|V.10|IND MCKA1C-01 Customer Care: 1-800-266-3745 (Toll Free)