Safety controller unit

Transcription

Safety controller unit
Version 1.0 
Safety controller unit
Compact design
463111B2 /
463114B2
+PLd in acc. with EN ISO 13849-1 / SILCL2 in acc. with
EN IEC 62061
+Two sensors can be directly connected
+ For sensors with 2-N.O. system
+Space-saving design for tight installation spaces
+Up to 16 sensors can be connected via an external
interface
+ LED status display
+Automatic start or manual start via start push button
Use
Types 463111B2 and 463114B2 are used for evaluating the signals from safety sensors. All elobau sensors with a 2-N.O. system can be connected to the unit. This unit can be used in any machine safety
application requiring SIL 2, PL d. Due to its compact design, the control unit is perfectly suited for
installation into small cabinets and machine housings.
Variants
Types 463111B2 and 463114B2 differ in respect to their operating voltages of 24 V DC or
230 V AC.
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
463111 / 114B2 – Version 1.0 
Page 1 of 7
Version
Mechanical assembly
Installation dimensions
Housing
94 x 75 x 25 mm
Installation
On DIN rail TH35 acc. to DIN EN 60715
Key mechanical data
Technology
Control unit for 2 - 16 2-N.O. sensors*
Material
PA (polyamide)
Weight
463111B2: approx. 120 g
463114B2: approx. 195 g
Operating temperature range
0°C to +55°C
Storage temperature
-25°C to +85°C
Housing protection class
IP40 EN 60529
Housing color
Black
* 2 sensors can be directly connected, and up to 16 via an additional interface
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
463111 / 114B2 – Version 1.0
Page 2 of 7
Version 
Approvals and safety-relevant technical specifications
Safety-relevant technical
specifications
SILCL 2 (EN IEC 62061)
PLd (EN ISO 13849-1)
Category 3 (EN ISO 13849-1)
PFHD 463111B2: 1.02e -8 1 / h
PFHD 463114B2: 9.69e -9 1 / h
Service life: 20 years
Approvals
TÜV / ETL (planned for 463111B2)
Key electrical data
463111B2
463114B2
Operating voltage
24 V DC ±10%
230 V AC ±10%
Current consumption
Max. 100 mA
Max. 25 mA
Status indication
3x LED
Monitoring
External contactor / start push button
Operating time
3s
Safety output
Switching voltage
250 V AC / 30 V DC
Switching current
3A
Switching power
750 VA / 90 W
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
463111 / 114B2 – Version 1.0 
Page 3 of 7
Version 
Wiring
463111B2
Logic
Logic
Input
Input
6
7
8
9
10
11
12
13
24 V DC
K1 K2
Output
Output
(+)
Sensor
11
(-)
(+)
Sensor
Sensor
22
(-)
5
External
External
contactor /
contactor/
Start Start
1
+
2
-
Safety
Safety
3
&
4
Ready
Ready
K2 K1
463114B2
Logic
Input
Logic
Input
6
7
8
9
10
11
12
13
230 V AC
K1 K2
Output
Output
(+)
Sensor
Sensor
11
(-)
(+)
Sensor
Sensor
22
(-)
5
External
External
contactor /
contactor/
Start Start
1
+
2
-
Ready
Ready
Safety
Safety
3
&
4
K2 K1
Illustration in de-energized state. Sensor(s) not actuated.
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
Input / 114B2 – Version 1.0 
Page 4 of 7
Version
Connection type
Terminal block
0.08 - 2.5 mm2
Terminals 1 + 2: UB
Terminals 3 + 4: safety output
Terminal 5: external contactor / start
push button
Terminals 6 – 9: sensor 1
Terminals 10 - 13: sensor 2
The integrated LEDs signal if the operating voltage is switched on and which sensors are connected.
After switching on the operating voltage, an automatic or monitored start is possible if all sensors
are operating properly.
Two safety sensors can be connected directly to the control unit. When using the following elobau
interfaces, the monitoring can be extended to up to 16 sensors:
363V99
363.97
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
Input / 114B2 – Version 1.0
Page 5 of 7
Version
Fax: +49 (0) 7561 970-100
E-Mail: [email protected]
Your
product
Specifi
cationsenquiry
of your safety controller unit
Version
463111B2 (UB = 24 V DC)
Quantity
463114B2 (UB = 230 V AC)
Batch size
Name / first name
Company
Address
Postal code / town
Country


E-Mail
Notes, questions, other
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
Input / 114B2 – Version 1.0
Page 6 of 7
Version
Fax: +49 (0) 7561 970-100
E-Mail: [email protected]
Your product enquiry
Quantity
Batch size
Name / first name
Company
Address
Postal code / town
Country


E-Mail
Notes, questions, other
The relevant corresponding technical documents will be supplied with the product.
Certain product descriptions can be similar therefore please ensure that you have the latest version of documentation for your
specific product prior to any use. elobau reserves the right to change technical data and documentation without notice.
elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany |  +49 (0) 7561 970-0  +49 (0) 7561 970-100 | www.elobau.com
Input / 114B2 – Version 1.0
Page 7 of 7

Similar documents

Ac ServO Sürücüler SiGMA-5 SEriSi - Yaskawa

Ac ServO Sürücüler SiGMA-5 SEriSi - Yaskawa Sigma-5 serisi, genel standartlara uygun olarak tasarlanmıştır. Haberleşme modülünü servopack'ler ve motorlarla birlikte kullanmak için takıp çalıştırmak yeterlidir. Bu hem mevcut işletmelerde ve m...

More information