JOC Oil less Air Compressor Installation Guide

Transcription

JOC Oil less Air Compressor Installation Guide
InstallationManual
JOCSeries
JOC11-115V
JOC12,JOC22,JOC32-208-230V
Notes:
-Compressorsystemmustbeinstalledperlocalplumbingandelectricalcodes
-Freshairintaketerminationpipetobeprovidedbyinstaller
Dryer
Coalescing
Filter
ElectricalBox
Pressure
Gauge
Moisture
Indicator
OfficeAirLine
SupplyConnection
Exhaust
Silencer
InstallationKitProvidedwithCompressorsIncludes:
1.ExhaustSilencer
2.FreshAirIntakeFilters
3.FeetwithHardware
4.OperatoryAirLine
ModelJOC22shown
ComponentsshownaretypicalonallJOCSeriesCompressors
CompressorSiteRequirements
Electrical
Model
Voltage
SinglePhase
DisconnectSwitchBox
DeliveryLine
JOC11
115
60Hz
20Amps
JOC12
208-230
60Hz
20Amps
JOC22
208-230
60Hz
30Amps
JOC32
208-230
60Hz
40Amps
Plumbing
CompressorExit:1/2"FPT
6'MainTrunkLineEnds:1/2"MPT
Environmental
EquipmentRoom
AmbientTemperature
RelativeHumidity
AtmosphericPressure
40°Fto104°F(4°Cto40°C)
10%to90%
500hPato1060hPa(0.49atmto1.05atm)
Disconnectingmeansshallbeinstalledwithinsiteoftheinstalledcompressor.
ImportantInformation
Intended Use
Toprovidecompressedairduringproceduresandexamsconductedbyqualifiedpersonnel.
Electromagnetic Interference
AllJDSoil-lesscompressorsaredesignedandmanufacturedtominimizeelectromagneticinterferencewithotherdevices.
However,ifinterenceisnoticedbetweenanotherdeviceandtheseunits:
-Removeinterferingdevicefromroom
-Plusinterferingdeviceintoanisolatedcircuit
-Increaseseparationbetweenunitandinteferingdevice
-ContactJDSifinterferenceremains
Disposal of Equipment
Attheendofproductlife,goodsandotheraccessories,includingtheunit,maybecomecontaminatedfromnormaluse.Consultlocalcodes
andordinancesforproperdisposalofequipment,accessoriesandotherconsumablegoods.
Installation
Note:Compressorsystemmustbeinstalledinanairconditionedorventilatedroomtoensureoperationalambient
temperature.A6"clearanceisrequiredbehindtheunitandonesidetoallowairflow.Failuretodosocancausepremature
lossofsystemperformanceandvoidwarranty.Also,donotinstallwithinpatientvincinityduetoelevatedtemperatures.
1.Removecompressorandaccessoriesfrombox.
2.Movecompressortoadry,wellventilateareaonasolid,levelsurface.
3.Installrubberfeet(Included).
4.Attachexhaustsilencerintobottomofsolenoid.
5.Connectfreshairintakefilterwiththeprovidedfittings.
WARNING:
Alwaysdisconnectthepowerbefore
servicing.Thesurfacesofthecompressor
head(s)canbecomeveryhotdepending
onusage.Donottouchthesepartsduring
ordirectlyafteroperation.
Rubber
Feet
ExhaustSilencer
Installation
6.ConnectremotepanelwirestoLowVoltageControlwires.(RefertotheControlPanelReferenceCrossWiringchartinsideofcover.)
7.ConnectConduitCabletousersuppliedelectricalbox.
8.Checktoseethattheshut-offvalveisclosed.
9.Turnpoweron.On/Offswitchesarelocatedinsidethecompressorelectricalbox.
10.Usesoapywatertocheckforleaks.
11.Opentheshut-offvalveslowlyandallowairtoflowintotheofficeairsystem.
12.Allowabout30secondsfortheofficeairlinestopressurize.Checkpressuregauge.
13.Checkgaugereadingafter10minutes.(Ifpressuregaugedrops,anairleakexists.Locateandrepairtheleak)
JOC11-115VModel
115Vsource
Singlephase,60Hz
20ampbreaker
Circuitbreakerbox
JOC12,JOC22,JOC32-208-230VModels
208-230Vsource
Singlephase,60Hz
20,30,or40ampbreaker
Circuitbreakerbox
WARNING:
TheOn/Offswitchonlycontrolthesecondarycircuitpower.Themainpowersourceisthecircuitbreakerpanel.Thecircuitbreaker
panelmustbeturnedofftoremoveallpowerinthecontrolbox.
PressureGauge
LowVoltageControlWires
On/OffSwitches(Inside)
Shut-offValve
ConduitCable
Note:ToaccessOn/Offswitches,loosenfourscrewsinfrontofelectricalboxtoremovecover.Replacecoverafterturning
switcheson.
Installation
AirPlumbingConnections
AppliestomodelsJOC11andJOC12.
ConnectthegrayPVCthatisattachedtothecompressor
headsbyvinylhoses.Connecttheintakeoftheairfilter
toanoutsideairsource.Ifnosuchconnectiontothe
outsideairexists,donotconnecttheintakeportionof
thefilter.
AppliestomodelsJOC22andJOC32.
ConnectthegrayPVCthatisattachedtothecompressor
headsbyvinylhoses.Connecttheintakeoftheairfilter
toanoutsideairsource.Ifnosuchconnectiontothe
outsideairexists,donotconnecttheintakeportionof
thefilter.
LowVoltageControlPanelWiring
Wheninstallingcontrolpanel,refertothecontrolpanelinstallationguideforinstructionsonhowtoconnectlowvoltage
wiresproperly.
Note:Topreventmoisturefromenteringthecompressor:
-Incomingfreshairtemperaturemustnotexceedroomtemperaturebymorethan20degreesFarenheitor-6degrees
Celsius.
-Freshairintakeshouldberoutedtooutsideairsource
-Tightbendsinhosesmaycausethemtocollapseandmayleadtoequipmentfailure.
JDSDentalProducts|21133NorwalkBlvd.HawaiianGardens,CA90716
[email protected]|www.JDSmfg.com|562-924-4300(Voice)|562-924-2273(Fax)