WVFC, WVFW - Sales

Transcription

WVFC, WVFW - Sales
Replacement Parts List No. 700012100
Revision L 10/2015
Daikin
McQuay
Enfinity™ Vertical
Water Source Heat Pump
WVFC, WVFW
009 - 070
Design 1
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Contents
Parts List Revision History.................................................................................................................................3
Nomenclature
Serial Number..............................................................................................................................................4
Model Number.............................................................................................................................................5
Cabinet...............................................................................................................................................................6
Blower Fan Assembly
Standard Motor, Housing & Wheel Assy......................................................................................................7
ECM Motor, Housing & Wheel Assy............................................................................................................8
Electric Heat.......................................................................................................................................................9
Refrigeration Circuit
Diagrams...................................................................................................................................................10
Sizes 009- 024 Components.....................................................................................................................11
Sizes 030- 070 Components.....................................................................................................................12
Desuperheater..................................................................................................................................................13
Water Flow Control Valve.................................................................................................................................14
Control Box MicroTech III Controls
Sizes 009, 012, 015...................................................................................................................................15
Sizes 019 - 070..........................................................................................................................................16
MTIII Control Board Label Location...........................................................................................................17
Compressor Capacitors.............................................................................................................................18
Field Installed Accessories........................................................................................................................ 19- 23
Critical Parts List
Sizes 009-024.......................................................................................................................................CPL1
Sizes 030-070.......................................................................................................................................CPL2
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 2
Parts List Revision History
Revision
Date Description New
01/09 New
A
05/09 Page 10- Ref # 360 change p/ns for ECM Blower Motors.
B
05/10 Page 8- Add Ring Terminal p/n 802007936 and Fastener-Dart p/n 061461701.
Page 25- Add Wire Harness Assy p/n 668995801.
C
06/10 Added sizes 009, 012 & 015 to RPL. Repaginated entire document.
D
06/10 Pages 22-23 Added H1-H9 Connectors. Added Edge-holder p/n 668395501.
Changed sensor and code descriptions. Added footnotes 1 & 2.
Page 25- Added Shutoff/Balancing Valves p/n 802026097 & p/n 802026098.
Page 26- Replace page with Field Accessories doc per Dan Adams. Pump Restart Relay Kit deleted.
E
09/11 Page 9- Change filter from 20 x 10 x1” to 26 x 8 x 1” for p/n 060604824.
Page 11- Add wheel p/n 060628001 for unit sizes 009 and 012.
Page 21- Add note includes H5 harness.
Pages 20-27 Numerous changes made to tubing, field accessories & control box.
Pages CPL1-2 Add Critical Parts List.
F
02/12 Title Page- Delete the 1 after the unit models.
Page CPL1-CPL2 Delete the 1 after the unit models.
G
10/12 Title Page- Change McQuay to Daikin McQuay and add EnfinityTM. Update to CS6.
Page 9- Change unit size heading from 024 030 to 036. Change filter p/n 060678125 to 060687125.
Page 18- Change Coil Assy p/n 668223139 to 668223153.
Page 23- Change Sensors (RAT, DAT) p/n 17201601 to 669008901.
H
12/12 Page 20- Move part number/unit size header over.
I
08/13 Page 12-Change Ref #M360 Std. Blower Motor p/n 688949305 to 668949305.
CPL1-2- Add Std. Blower Motor p/n 668949305 sizes 042-070.
J
10/13 Rebranded Daikin. Numerous changes made.
Page 9- Delete Filters and add to Field Installed Accessories.
Pages 11-12 Update ECM motors.
Page 20- Updated Reversing Valves & Solenoid.
Pages 22-23 Change LonMark p/n 668105801 to 107293070. Change BACnet p/n 668105901 to 107293070. Add I/O Exp p/n 668105702.
Page 24- Update Capacitors.
Pages 25-28 Updated Field Installed Accessories.
CPL1- Spilit CPL into two sections- for sizes 009-024 only. Update ECM.
CPL2- Continue with sizes 030-070 only. Removed Exp Valves. Update ECM.
K
03/15 Delete sheet metal. Numerous changes. Combined pages to Daikin Format. Delete pgs 6-9.
Page 6- Delete all sheet metal. Add footnote #1.
Page 7- Change motor, add ECM nameplate to diagrams.
Page 8- Change capacitor p/n 668003108 to 668300112. Update motor band & arms p/ns. Delete ECM motors & add footnote #1. Page 9- Delete 15 KW Electric Heater p/ns 668204804, 668204806, 668204808.
Page 10- Update Refrigeration Circuit diagrams. Page 11- Add 115V compressor size 012 p/n 668951504 & overload 668015802.
Page 13- Add Desuperheater diagram & components page.
Page 14- Add Water Flow Control valve diagram & components page.
Page 15- Add 75V transformers p/ns 910117810, 667715902, and 910116209. Change Ref#165 Contactor p/n 106500101 to 106500102. Change SLTS p/n 107201601 to 910121227. Delete connectors H-1 to H-9.
Page 16- Add 75V transformers p/ns 910116213, 667716209, 107228901, and 107511307. Change Ref#165 Contactor p/n 073322502 to 910140339. Delete connectors H-1 to H-9. Change SLTS p/n 107201601 to 910121228, 910121230 and 91012123.
Pages 18-22 Updated Field Installed Accessories- numerous changes.
CPL1-2- Update 115V compr size 012 & SLTS, delete comm cards & ECM motors.
L
10/15 Update to Daikin format. Pages 7-8 Move Std motor sizes to page 7 & page 8 add ECM motor table and footnote. Pages 15-17 Add MTIII Controls Label Location table and footnote.
CPL1-CPL2 Update to Daikin format. Split into two pages CPL1, 009-024 & CPL2, 0301-070.
Daikin Applied 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 3
Serial Nomenclature
Serial Number
AUB
U
08
11
00386
Plant Identification Abbreviation
AUB = Auburn
Serial Number
(build sequence)
Week of Manufacture
U= Unit
Year of Manufacture
08= 2008
09=2009
10= 2010
etc.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 4
Unit Model Nomenclature
W VFC 1 030 B J Y L T 04 YY A C A YY Y YYY YYY YYY A Y YYYY Y YYC 1 Y 1
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2424 25 26 272829
Code 01: Unit Type
W= Water Source Heat Pump
Code 13: Water to Refrigerant Heat Exchanger
C= Copper Inner Tube/ Steel Outer Tube
S= Cupro Nickel Inner Tube/ Steel Outer Tube
Y= None
Code 02: Product Identifier
VFC= R410a, Floor Mounted, Standard Range
VFW= R410a, Floor Mounted, Geothermal Range
Code 14: Heating Options
A= 5.0KW Electric Heat
B= 10.0KW Electric Heat
Y= None
Code 03: Design Series
1= Design 1
Code 15: Dehumidification
YY= None
Code 04: Unit Size (1000’s BTUH)
009= 9000
012= 12000
015= 15000
019= 19000
024= 24000
030= 30000
036= 36000
042= 42000
048= 48000
060= 60000
070= 70000
Code 16: Piping Hand
Y= None
Code 17: Thermostat Control
YYY= None
Codes 18: Night Control
YYY= None
Code 19: Desuperheater
DSH= Desuperheater
Code 05: Controls
B= MicroTech III Base Controller
C= MicroTech III Controller with LonCard
D= Microtech III Controller with BacNet Card
Code 20: Refrigerant
A= R410a
Code 21: Power Connection
Y= None
Code 06: Voltage
A= 115/60/1
E= 208/230/60/1
F= 208/230/60/3
J= 265/60/1
K= 460/60/3
L= 575/60/3
Code 22: Cabinet Electrical
75V= 75 Volt Control Transformer
YYY= None
Code 23: Water Flow Control
C= 2-Way Motorized 1/2” Iso Valve, Gen’l Close-Off Pr, N.C.
V= 2-Way Motorized 1/2” Iso Valve, Gen’l Close-Off Pr, N.O.
H= 2-Way Motorized 1/2” Iso Valve, High Close-Off Pr, N.C.
D= 2-Way Motorized 3/4” Iso Valve, Gen’l Close-Off Pr, N.C.
K= 2-Way Motorized 3/4” Iso Valve, Gen’l Close-Off Pr, N.O.
J= 2-Way Motorized 3/4” Iso Valve, High Close-Off Pr, N.C.
Y= None
Code 07: Cabinet Height
Y= None
Code 08: Return Air
L= Left Hand Return Air
R= Right Hand Return Air
Code 09: Discharge Air
T= Top Discharge
Code 24: Always Y
Code 25: Outside Air
Y= None
Code 10: Blower Motor
01= Standard
04= ECM Motor
Code 26: Agency
C= ETL, CETL, ARI, MEA
Code 11: Discharge Grille/ Cabinet Type
YY= None
Code 27: Packaging
1= Standard
Code 12: Construction Type
A= Standard
B= Standard w/2” Filter Rack
C= Standard w/Compressor Sound Blanket
D= Std w/ Compr Sound Blanket & 2” Filter Rack
E= Indoor Air Quality (IAQ)
F= IAQ w/2” Filter Rack
G= IAQ w/Compr Sound Blanket
H= IAQ w/Compr Sound Blkt & 2” Filter Rack
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
YYY= None
Code 28: Extended Warranty
Code 29: Product Style
1= Style 1
Rev. L 10/15
RPL 7000121 / Page 5
Cabinet
Cabinet/Chassis components
240
Ref.
No.
240
N/S
Unit
Sizes
Part
Number
Condensate Pan
009 - 012
106396801
Condensate Pan
015 - 036
106396802
Condensate Pan
042 - 070
106396804
Cabinet/Chassis Components
009 - 070
1
Part Description
N/S= Not Shown on diagram.
1
Please contact Daikin Applied with unit model and serial number for part numbers on Cabinet/Chassis components.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 6
Blower Fan Assembly
Standard Motor, Housing & Wheel Assy.
370
320
365
320
325
500
500
300
Unit Size 009-012
Ref.
No.
Part Description
Unit Size 015-070
Part
Number
Unit Size/ Quantity
009 012 015 019 024 030 036 042 048 060 070
N/S
Capacitor Bracket
850010570
1
1
300
Capacitor, 2 MFD, 440V
668003112
1
1
Capacitor, 3 MFD, 440V
668003104
1
1
Capacitor, 7.5 MFD, 440V
668003114
320
Capacitor, 20 MFD, 370V
668003111
Blower Housing
060699602
Blower Housing & Wheel Assy
667838701
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
1
1
1
1
1
1
Blower Housing & Wheel Assy
668151101
325
Wheel, Blower
060628001
365
Motor Band for Std. Motor
802009140
Motor Band for Std. Motor
910121966
370
Motor Arm for Std. Motor
668405401
Motor Arm for Std. Motor
910121965
500
Motor,1/8HP, 115/60/1
106646504
1
1
Motor,1/8HP, 208-230/60/1
106646501
1
1
Motor,1/8HP, 265/60/1
106646502
1
1
Motor,1/6HP, 208-230/60/1
073314501
1
1
1
Motor,1/6HP, 208-230/60/1
073314502
1
1
1
Motor,1/2HP, 208-230/60/1
060704601
1
1
Motor,1/2HP, 265/60/1
060704602
1
1
Motor,1/2HP, 460/60/1
060704603
1
1
Motor,1/2HP, 208-230/60/1
668949301
1
1
1
1
Motor,1/2HP, 265/60/1
668949303
1
1
1
1
Motor,1/2HP, 460/60/1
668949302
1
1
1
1
Motor,1/2HP, 575/60/1
668949305
1
1
1
1
1
1
1
1
1
1
3
3
3
3
N/S= Not Shown on diagram.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 7
Blower Fan Assembly
ECM Motor, Housing & Wheel Assy
365
370
NP
WARNING
LABEL
400
ECM Motor
Nameplate
Ref.
No.
N/S
365
370
400
1
ECM Motor Mount
Detail
Part
Number
Part Description
Blower Housing & Wheel Assy
667838701
Blower Housing & Wheel Assy
669286110
Band, Motor Mount
802009140
Band, Motor Mount
910121966
Arm, Motor Mount
668405401
Arm, Motor Mount
910121965
ECM & Program
Unit Size/ Quantity
019 024 030 036 042 048 060 070
1
1
3
1
1
1
3
1
1
3
1
1
1
1
1
1
1
1
1
3
3
3
3
1
3
See ECM motor nameplate.
The PN for the ECM motor is found on the label (see illustration above).
You may also contact Daikin with the Unit Model & Serial Number to get the ECM Motor part number.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 8
Electric Heat
Sizes 019-070
600
Ref.
No.
600
Part
Number
Part Description
Unit Size/ Quantity
019 024 030 036 042 048 060 070
Electric Heater, 5KW, 208-230/60/1
668204701
1
1
1
1
Electric Heater, 5KW, 265/60/1
668204704
1
1
1
1
Electric Heater, 10KW, 208-230/60/1
668204702
1
1
1
1
Electric Heater, 10KW, 208-230/60/3
668204703
1
1
1
1
Electric Heater, 10KW, 265/60/1
668204705
1
1
1
1
Electric Heater, 10KW, 460/60/3
668204706
1
1
1
1
Electric Heater, 10KW, 208-230/60/1
668204801
1
1
1
1
Electric Heater, 10KW, 208-230/60/3
668204803
1
1
1
1
Electric Heater, 10KW, 265/60/1
668204805
1
1
1
1
Electric Heater, 10KW, 460/60/3
668204807
1
1
1
1
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 9
Refrigeration Circuit
Diagrams
Evaporator/ TXV Detail
92
Condenser Detail
859
71
69
Compressor
57
58
61
Reversing Valve Piping
TXV Bulb
Unit Size
009-015
137
160
Unit Size
019-070
Compressor Mounting
Detail
136
100
Coremax Valve Assy Detail
151A
Coremax Valve Assy
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
151B
151C
RPL 7000121 / Page 10
Refrigeration Circuit
Sizes 009-024 Components
Ref.
Unit Size
No. Description Part Number 009 012 015 019 024
57
Nut- Compressor, Mount 802012035
3 3 3 4 4
58
Sleeve, Compr. Mounting 668955501
3 3 3
Sleeve- Compressor Mounting 060623401
4 4
61
Grommet- Compressor Mounting 668955401
3 3 3
Grommet- Compressor Mounting 4RHZ9154
4 4
69
Compressor
115V 668951401
1
Compressor
115V 668951504
1
Compressor
208-230V 668951411
1
Compressor
208-230V 668951501
1
Compressor
208-230V 668951601
1
Compressor
208-230V 668172001
1
Compressor
208-230V 668392101
1
Compressor
265V 668951412
1
Compressor
265V 668951503
1
Compressor
265V 668951603
1
Compressor
265V 668172002
1
Compressor
265V 668392102
1
N/S
Overload, Compressor
115V 668015802
1 1
Overload, Compressor
208-230V 668015804
1
Overload, Compressor
208-230V 668015806
1
Overload, Compressor
208-230V 668015808
1
Overload, Compressor
265V 668015805
1
Overload, Compressor
265V 668015805
1
Overload, Compressor
265V 668015810
1
N/S
Compressor Blanket 669280501
1 1
71
92
Condenser Copper Inner Tube
Condenser Copper Inner Tube
Condenser CuproNickel Inner Tube
Condenser CuproNickel Inner Tube
Evaporator Coil Assy
Evaporator Coil Assy
067789501
1 1
667718301
067789502
1 1
667718302
668223163
1 1
668223160
100
N/S
Reversing Valve Reversing Valve Reversing Valve Reversing Valve Solenoid Valve Solenoid Valve until 3/11
3/11 & later
until 3/11
3/11 & later
until 3/11
3/11 & later
136
High Pressure Switch
until 7/11
High Pressure Switch
7/11 & later
137
Low Pressure Switch
22 ± 7 PSI
151A Seat- Fitting
.375
151B Core- Valve
151C Cap- Valve
160
Fusible Plug Assy
Plug only
283° F
859
Expansion Valve 3/4T
Expansion Valve 1T
Expansion Valve 2T
1
1
1
1
1
1
1
1
1
106694111
1 1 1
910110426
1 1 1
106694113
910110428
106694207
1 1 1
910110439
1 1 1
1
1
1
1
1
1
1
1
106483301
1 1 1 1
910117560
1 1 1 1
107225101
1 1 1 1
668188801
2 2 2 2
668188701
2 2 2 2
668189501
2 2 2 2
850001662
1 1 1 1
106057401
1 1 1 1
106489116
1 1
106489119
1 1
106489112
1
1
1
2
2
2
1
1
1
NS = Not Shown
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 11
Refrigeration Circuit
Sizes 030-070 Components
Ref. Unit Size
No.
Description Part Number 030 036 042 048 060
57
Hex Nut- Compressor Mounting 802012035
4 4 4 4 4
58
Sleeve, Compr. Mounting 060623401
4 4 4 4 4
61
Grommet- Compressor Mounting 4RHZ9154
4 4 4 4 4
69
Compressor
208-230/60/1 668405701
1
Compressor
208-230/60/1 668392201
1
Compressor
208-230/60/1 668407001
1
Compressor
208-230/60/1 668408001
1
Compressor
208-230/60/1 668407601
1
Compressor
208-230/60/3 668405702
1
Compressor
208-230/60/3 668392202
1
Compressor
208-230/60/3 668407002
1
Compressor
208-230/60/3 668408002
1
Compressor
208-230/60/3 668407602
1
Compressor
208-230/60/3 668220001
Compressor
265/60/1 668405703
1
Compressor
460/60/3 668392203
1
Compressor
460/60/3 668407003
1
Compressor
460/60/3 668408003
1
Compressor
460/60/3 668407604
1
Compressor
460/60/3 668220002
Compressor
575/60/3 668407004
1
Compressor
575/60/3 668408004
1
Compressor
575/60/3 668407605
1
Compressor
575/60/3 668220003
N/S
Compressor Blanket 669280501
1 1
N/S
Compressor Blanket 669280601
1 1 1
71
Condenser Copper Inner Tube 667718501
1 1
Condenser Copper Inner Tube 667718601
1 1
Condenser Copper Inner Tube 667718801
1
Condenser CuproNickel Inner Tube 667718502
1 1
Condenser CuproNickel Inner Tube 667718602
1 1
Condenser CuproNickel Inner Tube 667718802
1
92
Evaporator Coil Assy
28 X 18 668223159
1 1
Evaporator Coil Assy
24 X 26.25 668223158
1 1
Evaporator Coil Assy
36 X 26.25 668223161
1
100
Reversing Valve
until 3/11 106694107
1 1 1 1
Reversing Valve
3/11 & later 910110422
1 1 1 1
Reversing Valve until 3/11 106694109
1
Reversing Valve 3/11 & later 910110424
1
N/S
Solenoid Valve
until 3/11 106694207
1 1 1 1 1
Solenoid Valve 3/11 & later 910110439
1 1 1 1 1
136
High Pressure Switch
until 7/11 106483301
1 1 1 1 1
High Pressure Switch
7/11 & later 910117560
1 1 1 1 1
137
Low Pressure Switch
22 ± 7 PSI 107225101
1 1 1 1 1
151A Seat- Fitting
.375 668188801
2 2 2 2 2
151B Core- Valve 668188701
2 2 2 2 2
151C Cap- Valve 668189501
2 2 2 2 2
160
Fusible Plug Assy 850001662
1 1 1 1 1
Plug only
283° F 106057401
1 1 1 1 1
859
Expansion Valve 2T 106489112
1
Expansion Valve 3T 106489111
1
Expansion Valve 3T 106489120
1
Expansion Valve 4T 106489121
1
Expansion Valve 5T 106489122
1
Expansion Valve 6T 106489123
070
4
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
1
1
1
N/S = Not Shown
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 12
Desuperheater
100
050
Ref.
No.
050
100
Part Description
Part
Number
Circulation Pump, 115/60/1
668200902
Circulation Pump, 208-230/60/1
668200901
Desuperheater Coil, Copper
668169101
Desuperheater Coil, Cupronickel
668169102
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 13
Water Flow Control Valve
150
Ref.
No.
150
Unit Sizes
Part
Number
2-Way Modulating Isolation Valve, 1/2”
009 - 024
107179603
2-Way Modulating Isolation Valve, 3/4”
030 - 070
107202003
Actuator Motor, High Close-Off, NC
009 - 070
107179807
Actuator Motor, NO
009 - 070
107179808
Actuator Motor, NC
009 - 070
107179809
Part Description
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 14
Control Box
MicroTech III Controls
Sizes 009-015
180
165
170
060
Unit Size
Ref.# Description Part Number 009 012 015
060 Control Board, MicroTech III 668105601*
1
1
1
N/S LED Annunciator 668395201
1
1
1
N/S Standoff
PC Board
Edge-holders
(Comm card only)
165 Relay, DPST until 3/13
Relay, DPST 3/13 & later
802028115
668395501
8
4
8
4
8
4
106500101
106500102
1
1
1
1
1
1
170 Relay, 1PDT
056992205
1
1
1
180
N/S
N/S
N/S
Transformer, 50VA- 115V
until 3/11
Transformer, 50VA- 115V
3/11 & later
Transformer, 50VA- 208/230V
until 3/11
Transformer, 50VA- 208/230V
3/11 & later
Transformer, 50VA- 277V
until 3/11
Transformer, 50VA- 277V
3/11 & later
Transformer, 75VA- 115V
Transformer, 75VA- 208/230V
Transformer, 75VA- 277V
060630802
910116204
060614102
910116202
060630702
910116203
910117810
910116213
910116209
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Line Temp Sensor (SLTS) Line Temp Sensor (SLTS) Air Temp Sensor (DAT, RAT) Water Temp Sensor (LWT) 107201601
910121227
669008901
107201601
1
1
1
1
1
1
1
1
until 2/12
2/12 & later
10K/72”
10K/80”
1
1
1
1
1
1
1
1
1
1
N/S= Not shown on diagram.
* When ordering this board, please provide the software part number printed on the board’s label.
See control board photo for label location (on the page after MTIII controls size 019-070).
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 15
Control Box
MicroTech III Controls
Sizes 019-070
A
180
080
170
220
160
060
A
Section A-A
Section B-B
Part Unit Size
Ref.# Description Number
019 024 030 036 042
060 Control Board, MicroTech III 668105601* 1 1 1 1 1
080 Control Board, IO Exp. for MTIII 668105702* 1 1 1 1 1
N/S LED Annunciator 668395201 1 1 1 1 1
N/S Standoff
PC Board 802028115
8 8 8 8 8
Edge-holders
(Comm card only) 668395501 4 4 4 4 4
160 Contactor, Compressor
until 3/13 073322502 1 1 1 1 1
Contactor, Compressor
3/13 & later 910140339 1 1 1 1 1
170 Relay, 1PDT 056992205 1 1 1 1 1
180 Transformer, 50VA- 208/230V
until 3/11 060614102 1 1 1 1 1
Transformer, 50VA- 208/230V
3/11 & later 910116202
1 1 1 1 1
Transformer, 50VA- 277V until 3/11 060630702 1 1 1
Transformer, 50VA- 277V 3/11 & later 910116203
1 1 1
Transformer, 50VA- 380V until 3/11 107228901
Transformer, 50VA- 380V 3/11 & later 910116216
Transformer, 50VA- 460V until 3/11 060676002
1 1
Transformer, 50VA- 460V 3/11 & later 910116205
1 1
Transformer, 50VA- 575V 056340705
1
Transformer, 75VA, 208/230V 910116213
1 1 1 1 1
Transformer, 75VA, 277V 910116209
1 1 1
Transformer, 75VA, 380V 107228901
Transformer, 75VA, 460V 910116209
1 1
Transformer, 75VA, 575V 107511307
1
220 Terminal Block, 1-PH 668989901 1 1 1 1 1
Terminal Block, 3-PH 668989902 1 1 1 1 1
N/S
N/S
N/S
Line Temp Sensor (SLTS)
Line Temp Sensor (SLTS)
Line Temp Sensor (SLTS)
Line Temp Sensor (SLTS)
Air Temp Sensor (DAT, RAT)
Water Temp Sensor (LWT) until 2/12 2/12 & later 2/12 & later 2/12 & later 10K/72”
10K/80” 107201601 910121230 910121228 910121231 669008901
107201601
1
1
1
1
1
1
1
1
048
1
1
1
060
1
1
1
070
1
1
1
8
4
1
1
1
1
1
8
4
1
1
1
1
1
8
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N/S= Not shown on diagram.
* When ordering this board, please provide the software part number printed on the board’s label.
See control board photo on next page for label location.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 16
Control Box
MicroTech III Controls
MTIII Control Board
Label Locations
Label
Label
668105702
668105901
Label
Label
668105601
668105801
NOTE: When ordering the control board, please provide the software part number printed on the board’s label.
See above for label locations.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 17
Control Box
MicroTech III Controls
Compressor Capacitors
100
150
PartUnit Sizes
Ref.#
Description
Number
009 012 015 019 024 030 036 042 048 060 070
100 Compressor Capacitor 115V
55 MFD 370V
until 3/12 067291522 1 1
55 MFD 370V
3/12 & later 910120054 1 1
Compressor Capacitor 208/230V
25 MFD 370V
until 3/12 669450001 1
25 MFD 370V
3/12 & later 910120048 1
30 MFD 370V
until 3/12 067291518
1
1
30 MFD 370V
3/12 & later 910120049
1
1
35 MFD 370V
until 3/12 067291516
1
1
35 MFD 370V
3/12 & later 910120050
1
1
40 MFD 370V
until 4/12 802007850
1
40 MFD 370V
4/12 & later 910120051
1
45 MFD 370V
until 4/12 067291523
1 1
45 MFD 370V
4/12 & later 910120052
1 1
70 MFD 370V
until 3/12 067291536
1
70 MFD 370V
3/12 & later 910120057
1
80 MFD 370V
until 4/12 067291528
1
80 MFD 370V
4/12 & later 910110424
1
Compressor Capacitor 265V
20 MFD 370V
until 4/12 067291511 1 1
20 MFD 370V
4/12 & later 910120047 1 1
35 MFD 370V
until 4/12 067291515
1
35 MFD 370V
until 4/12 067291516
1
35 MFD 370V
4/12 & later 910120050
1 1
40 MFD 370V
until 4/12 802007850
1 1
40 MFD 370V
4/12 & later 910120051
1 1
150 Capacitor Bracket 850010570 1
1
1
1
1
1
1
1
1
1
NOTE: Compressor Capacitor not required for 3 phase units.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 18
Field Installed Accessories
Filters
Description Filter, 1” Throwaway
20x10x1
Kit, Filter, Air 12/Box
Filter, 1” Throwaway
20x24x1
Kit, Filter, Air 12/Box
Filter, 1” Throwaway
14x20x1
Kit, Filter, Air 12/Box
Filter, 1” Throwaway
24x30x1
Kit, Filter, Air 12/Box
Filter, 1” Throwaway
18x30x1
Kit, Filter, Air 12/Box
Filter, 2” Throwaway
20x10x2
Kit, Filter, Air 12/Box
Filter, 2” Throwaway
20x24x2
Kit, Filter, Air 12/Box
Filter, 2” Throwaway
14x20x2
Kit, Filter, Air 12/Box
Filter, 2” Throwaway
24x30x2
Kit, Filter, Air 12/Box
Filter, 2” Throwaway
18x30x2
Kit, Filter, Air 12/Box
Filter, 2” Merv 8 Pleated 20x10x2
Kit, Filter, Pleated 12/Box
Filter, 2” Merv 8 Pleated 20x24x2
Kit, Filter, Pleated 12/Box
Filter, 2” Merv 8 Pleated 14x20x2
Kit, Filter, Pleated 12/Box
Filter, 2” Merv 8 Pleated 24x30x2
Kit, Filter, Pleated 12/Box
Filter, 2” Merv 8 Pleated 18x30x2
Kit, Filter, Pleated 12/Box
Part Unit Size
Number 009 012 015 019 024 030 036 042 048 060 070
106535004 1 1
668993601 1 1
060604826
1 1 1
668993603
1 1 1
1
1
060604827
1
1
668993604
1
1
060604808
1
1
668993605
1
1
060604828
1
1
668993606
1
1
060687119
6689878011 1
668987801 111
668987803 111
06068712411
66898780411
1
0606871091
1
1
668987805
1
1
060687125
1
1
668987806
6695752011 1
6695753051 1
669575203 111
669575303 111
66957520211
66957530211
1
6695752051
1
1
669575304
1
6695752041
1
6695753061
Filter Racks
Description 2” Filter Rack
Unit Sizes 009, 012
Unit Sizes 015, 019, 024
Unit Sizes 030, 036
Unit Sizes 042, 048
Unit Sizes 060, 070
Left Hand
Right Hand
Qty.
668987901
668987907
668987908
668987909
668987910
668987902
668987903
668987904
668987905
668987906
1
1
1
1
1
2 “ Filter Rack, Painted
Unit Sizes 009, 012
Unit Sizes 015, 019, 024
Unit Sizes 030, 036
Unit Sizes 042, 048
Unit Sizes 060, 070
668987919
668987911
668987912
668987913
668987914
668987920
668987915
668987916
668987917
668987918
1
1
1
1
1
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 19
Field Installed Accessories
Motorized Valves
Description
2-Way Valve Kit, Motorized, Normally Closed (NC), 1/2” NPT
2-Way Valve Kit, Motorized, Normally Open (NO), 1/2” NPT 2-Way Valve Kit, Motorized, Normally Closed (NC), 1/2” NPT
2-Way Valve Kit, Motorized, Normally Closed (NC), 3/4” NPT
2-Way Valve Kit, Motorized, Normally Open (NO), 3/4” NPT 2-Way Valve Kit, Motorized, Normally Closed (NC), 3/4” NPT
Unit Size
009-024
009-024
009-024
030-070
030-070
030-070
Kit *
668996001
668996002
668996003
668996004
668996005
668996006
Actuator
107179801
107179810
107179807
107179801
107179810
107179807
Body
107210401
107210401
107210401
106196601
107210601
107210601
* Refer to IM 1151 for installing a motorized valve kit on MicroTech III units.
Manual Valves, Relays & H-8 Harness Assy
Description Shutoff/Balancing Valve, 1/2” w/Memory Stop
2/Pack
Kit, Shutoff/Balancing Valve, 1/2”
10/Pack
Shutoff/Balancing Valve, 3/4” w/Memory Stop
2/Pack
Kit, Shutoff/Balancing Valve, 3/4”
10/Pack
Shutoff/Balancing Valve, 1” w/Memory Stop
2/Pack
Kit, Shutoff/Balancing Valve, 1”
12/Pack
Output Wire Harness Assy Kit, H-8, MTIII
Pump Restart Relay Kit
MicroTech III to MarkIV Daisy Chain Adaption for “E” & “U”
Unit Sizes
Part Number 009- 024 030- 070
106065102
1
106065110
1
106065202
1
1
106065210
1
1
106065302
1
106065310
1
910107989
1
1
061419001
1
1
910151282
1
1
Thermostats & Sensors
Description
RCN wireless housing and controls kit for use w/wireless Tstat
Remote Temperature Sensor for thermostats 668375301 & 668375401
Remote Sensor & Thermostat, Programmable & Digital Display, 2-Stage ACO/MCO
Digital Room Temperature Sensor, Temp & Humidity Display
Wall, Stat- AC/DC, ACO, 7 Day Programmable, 2 Heat/2 Cool with Wall Plate
Wall, Stat- AC/DC, ACO, Non-Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate
Wall Plate, Insulated for 910116773
Part Number
910105604
107096010
910116773
910121754
668375301
668375401
910116770
TStat Guards
Description
TStat Guard TStat Guard (10 Pack)
Part Number
105571101
105571110
MTIII Communication Module Kits
Description
BacNet Comm Module *
LonWorks Comm Module *
Part Number
107293071
107293070
* Kit includes comm module card, sensors, mounting tabs, and IM.
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 20
Field Installed Accessories
Hoses 009-036
Description
Unit Sizes Specification Part Number
009-036
3/4" NPT X 2'
106063801
Hose Assy, Fire Rated Condensate
009-036
3/4" NPT X 3'
106063901
009-036 3/4” NPT X 30” 106063701
009-036
3/4” NPT X 2’
106665101
Hose Assy, Fire Rated Supply/Return
009-036
1/2” NPT X 3'
106063101
009-036
1/2” NPT X 2’
106062801
Hose Assy, Fire Rated Supply/Return w/Shut-Off Ball Valve 009-036
1/2” NPT X 3’
669481302
009-036
1/2” NPT X 2’
669483401
Hose Assy, Fire Rated Supply/Return w/Ball Valve, 009-036
1/2” NPT X 3’
669481802
“Y” Strainer and Blowdown Valve
009-036
1/2” NPT X 2’
669481801
Flow Control Hose Kit- Fire Rated Supply/Return
009-036
1.5 GPM
669482303
Includes: Supply Ball Valve, Auto Flow Control Valve, 2.0 GPM
669482304
24” SSTL Hose. 2.5 GPM
669482305
3.0 GPM
669482306
3.5 GPM
669482307
4.0 GPM
669482308
4.5 GPM
669482309
5.0 GPM
669482310
5.5 GPM
669482311
6.0 GPM
669482312
Flow Control Hose Kit- Fire Rated Supply/Return
009-036
1.5 GPM
106582903
Includes: Supply Ball Valve, Auto Flow Control Valve, 2.0 GPM
106582904
Y-Strainer, and Blowdown, 24” SSTL Hose. 2.5 GPM
106582905
3.0 GPM
106582906
3.5 GPM
106582907
4.0 GPM
106582908
4.5 GPM
106582909
5.0 GPM
106582910
5.5 GPM
106582911
6.0 GPM
106582912
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 21
Field Installed Accessories
Hoses 042-070
Description
Unit Sizes Specification Part Number
042-070
3/4" NPT X 2'
106063801
Hose Assy, Fire Rated Condensate
042-070
3/4" NPT X 3'
106063901
042-070 3/4” NPT X 30” 106063701
042-070
3/4” NPT X 2’
106665101
Hose Assy, Fire Rated Supply/Return
042-070
3/4” NPT X 3’
106063201
042-070
3/4” NPT X 2’
106062901
Hose Assy, Fire Rated Supply/Return w/Shut-Off Ball Valve 042-070
3/4”” NPT X 3’
669481402
042-070
3/4” NPT X 2’
669483501
Hose Assy, Fire Rated Supply/Return w/Ball Valve, 042-070
3/4”” NPT X 3’
669481902
042-070
3/4” NPT X 2’
669481901
Flow Control Hose Kit, Fire Rated Supply/Return
042-070
3.0 GPM
106582913
Includes: Supply Ball Valve, Auto Flow Control Valve,
3.5 GPM
106582914
36” SSTL Hose. 4.0 GPM
106582915
4.5 GPM
106582916
5.0 GPM
106582917
5.5 GPM
106582918
6.0 GPM
106582919
6.5 GPM
106582920
7.0 GPM
106582921
7.5 GPM
106582922
8.0 GPM
106582923
9.0 GPM
106582924
10.0 GPM
106582925
11.0 GPM
106582926
12.0 GPM
106582927
13.0 GPM
106582928
15.0 GPM
106582929
Flow Control Hose Kit, Fire Rated Supply/Return
042-070
3.0 GPM
106582913
Includes: Supply Ball Valve, Auto Flow Control Valve,
3.5 GPM
106582914
Y-Strainer, and Blowdown, 36” SSTL Hose. 4.0 GPM
106582915
4.5 GPM
106582916
5.0 GPM
106582917
5.5 GPM
106582918
6.0 GPM
106582919
6.5 GPM
106582920
7.0 GPM
106582921
7.5 GPM
106582922
8.0 GPM
106582923
9.0 GPM
106582924
10.0 GPM
106582925
11.0 GPM
106582926
12.0 GPM
106582927
13.0 GPM
106582928
15.0 GPM
106582929
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 22
Field Installed Accessories
Microtech III Temperature Sensors
Part
Kit
Tenant
Set Point
Status LED
Fan & Number Override
Adjustment
Mode Switches
669088101
669529001
Yes
No
No
No
668900801
669529101
Yes
55˚ to 95˚F (12˚ to 35˚C)
Yes
Yes
669088201
669529201
Yes
-3˚ to +3˚F (-1.5˚ to 1.5˚C)
No
Yes
Note: Can only be used in conjunction with a Communication (Comm.) card. See OM 931 for required jumper settings.
Microtech III Unit Control Accessories
Description
Part Number
** Multiple Unit Control Panel:
Allows a master unit controlled by a T'Stat, to operate up to 3 secondary units
056794201
Not Recommended for use with a Boilerless System Kit
Boilerless System Kit with I/O Expansion Board
Boilerless System Kit without I/O Expansion Board
910110355
910110353
** Kit components listed below.
Multiple Unit Control Panel Kit
310
311
313
Ref. Description
No.
310 Cover- Control Box
311 Circuit Board
312 Stand Off- Circuit Board
313 Box
Part No. Qty.
106436101
056794001
802028090
850007827
1
1
6
1
312
WSHP, Vertical; WVFC1, WVFW1 009-070 Design 1
Rev. L 10/15
RPL 7000121 / Page 23
Critical Daikin Applied OEM Parts
Are What Your HVAC Unit Needs!
Daikin Enfinity™ Vertical WSHP
McQuay Enfinity™ Vertical WSHP
WVFC, WVFW
009 - 024 Design 1
Critical Components
Control
Control Board, MicroTech III
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Blower Motor
Standard Motor, 1/8HP
Standard Motor, 1/8HP
Standard Motor, 1/8HP
Standard Motor, 1/8HP
Standard Motor, 1/8HP
ECM & Program
Blower Housing and Wheel
Housing
Housing & Wheel Assy
Wheel, Blower
Sensor
Line Temp Sensor (SLTS)
Line Temp Sensor (SLTS)
Air Temp Sensor (DAT, RAT)
Water Temp Sensor (LWT)
Unit Sizes
Voltage
Part Number
ALL
ALL
668105601
009
009
009
012
012
012
015
015
019
019
024
024
115/60/1
208-230/60/1
265/60/1
115/60/1
208-230/60/1
265/60/1
208-230/60/1
265/60/1
208-230/60/1
265/60/1
208-230/60/1
265/60/1
668951401
668951411
668951412
668951504
668951501
668951503
668951601
668951603
668172001
668172002
668392101
668392102
009, 012
009, 012
009, 012
015 - 024
015 - 024
ALL
115/60/1
208-230/60/1
265/60/1
208-230/60/1
265/60/1
ALL
106646504
106646501
106646502
073314501
073314502
See motor nameplate
009, 012
015 - 024
009, 012
N/A
N/A
N/A
060699602
667838701
060628001
009 - 015
019, 024
ALL
ALL
N/A
N/A
N/A
N/A
910121227
910121230
669008901
107201601
Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
7000121 Rev. L 10/2015
CPL Page 1 of 2
Critical Daikin Applied OEM Parts
Are What Your HVAC Unit Needs!
Daikin Enfinity™ Vertical WSHP
McQuay Enfinity™ Vertical WSHP
WVFC, WVFW
030 - 070 Design 1
Critical Components
Control
Control Board, MicroTech III
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Compressor
Blower Motor
Standard Motor, 1/2HP
Standard Motor, 1/2HP
Standard Motor, 1/2HP
Standard Motor, 1/2HP
Standard Motor, 1/2HP
Standard Motor, 1/2HP
Standard Motor, 1/2HP
ECM & Program
Blower Housing and Wheel
Housing & Wheel Assy
Housing & Wheel Assy
Sensor
Suction Line Temp Sensor (SLTS)
Suction Line Temp Sensor (SLTS)
Air Temp Sensor (DAT, RAT)
Water Temp Sensor (LWT)
Unit Sizes
Voltage
Part Number
ALL
ALL
668105601
030
030
030
036
036
036
042
042
042
042
048
048
048
048
060
060
060
060
070
070
070
208-230/60/1
208-230/60/3
265/60/1
208-230/60/1
208-230/60/3
460/60/3
208-230/60/1
208-230/60/3
460/60/3
575/60/3
208-230/60/1
208-230/60/3
460/60/3
575/60/3
208-230/60/1
208-230/60/3
460/60/3
575/60/3
208-230/60/3
460/60/3
575/60/3
668405701
668405702
668405703
668392201
668392202
668392203
668407001
668407002
668407003
668407004
668408001
668408002
668408003
668408004
668407601
668407602
668407604
668407605
668220001
668220002
668220003
030, 036
030, 036
030, 036
042 - 070
042 - 070
042 - 070
042 - 070
ALL
208 - 230/60/1
265/60/1
460/60/1
208 - 230/60/1
265/60/1
460/60/1
575/60/1
ALL
060704601
060704602
060704603
668949301
668949303
668949302
668949305
See motor nameplate
030, 036
042 - 070
N/A
N/A
667838701
668151101
030 - 048
060, 070
ALL
ALL
N/A
N/A
N/A
N/A
910121228
910121231
669008901
107201601
Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.
To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
7000121 Rev. L 10/2015
CPL Page 2 of 2

Similar documents

Daikin McQuay Horizontal-Concealed Fan Coil

Daikin McQuay Horizontal-Concealed Fan Coil Engineering Guide Specifications . . . . . . . . . . . . . . 11

More information

MERV 13 - Best Air Pro

MERV 13 - Best Air Pro 847.683.7301 fax [email protected] www.bestairpro.com Due to continuous product research and enhancements, BestAir PRO reserves the right to change product components and specifications without n...

More information