TrackScan - MRD Rail Technologies Pty Ltd
Transcription
TrackScan - MRD Rail Technologies Pty Ltd
TrackScan Frequency Selective Meter TrackScan Frequency Selective Meter has been designed to measure voltages at specific ML/EB/ABB TI21, CSEE, Aster/SF and Westinghouse FS2500 series track circuit frequencies. Measurements can be made without corruption from other track circuits or interference at non selected track circuit frequencies. e.g. 50/60Hz. TrackScan can also measure track circuit current in the running rails when used in conjunction with the flexible current loop accessory (not included). The meter is supplied with a carrying case and test lead set. JADE B ML/EB/ABB TI21 CSEE UM71 AF WESTINGHOUSE FS2500 1595 Hz A - 1699 Hz 1700 Hz 1 1894 Hz C - 1996 Hz 2000 Hz 2 2206 Hz B - 2296 Hz 2300 Hz 3 2500 Hz D - 2593 Hz 2600 Hz 4 2841 Hz E - 1548 Hz 3157 Hz F - 2146 Hz 3472 Hz G - 1848 Hz 3750 Hz H - 2445 Hz BROADBAND 10 Hz - 4.5KHz SPECIFICATION Input Voltage Range 20mVrms - 200Vrms Passband Ripple @ Fc +/- 150Hz +/- 1% Attenuation @ Fc +/- 150Hz 80dB Battery Life 8 Hours PART NUMBERS TrackScan Frequency Selective Meter TRACKSCAN SPARES & ACCESSORIES Bag TS-BAG Battery Charger TS-BC MRD Rail Technologies Pty Ltd 235 South Street Cleveland Q 4163 Ph: 61 7 3821 5151 Fx: 61 7 3821 5152 www.mrd.com.au