TrackScan - MRD Rail Technologies Pty Ltd

Transcription

TrackScan - MRD Rail Technologies Pty Ltd
TrackScan
Frequency Selective Meter
TrackScan Frequency Selective Meter has been designed to measure
voltages at specific ML/EB/ABB TI21, CSEE, Aster/SF and
Westinghouse FS2500 series track circuit frequencies. Measurements
can be made without corruption from other track circuits or interference
at non selected track circuit frequencies. e.g. 50/60Hz. TrackScan can
also measure track circuit current in the running rails when used in
conjunction with the flexible current loop accessory (not included). The
meter is supplied with a carrying case and test lead set.
JADE B
ML/EB/ABB TI21
CSEE UM71 AF
WESTINGHOUSE FS2500
1595 Hz
A - 1699 Hz
1700 Hz
1
1894 Hz
C - 1996 Hz
2000 Hz
2
2206 Hz
B - 2296 Hz
2300 Hz
3
2500 Hz
D - 2593 Hz
2600 Hz
4
2841 Hz
E - 1548 Hz
3157 Hz
F - 2146 Hz
3472 Hz
G - 1848 Hz
3750 Hz
H - 2445 Hz
BROADBAND 10 Hz - 4.5KHz
SPECIFICATION
Input Voltage Range
20mVrms - 200Vrms
Passband Ripple @ Fc +/- 150Hz
+/- 1%
Attenuation @ Fc +/- 150Hz
80dB
Battery Life
8 Hours
PART NUMBERS
TrackScan Frequency Selective Meter
TRACKSCAN
SPARES & ACCESSORIES
Bag
TS-BAG
Battery Charger
TS-BC
MRD Rail Technologies Pty Ltd
235 South Street
Cleveland Q 4163
Ph: 61 7 3821 5151
Fx: 61 7 3821 5152
www.mrd.com.au