Teleradiology applications with DICOM-e-mail

Transcription

Teleradiology applications with DICOM-e-mail
Eur Radiol (2007) 17: 1331–1340
DOI 10.1007/s00330-006-0450-8
COMPUTER APPLICATI ONS
G. Weisser
U. Engelmann
S. Ruggiero
A. Runa
A. Schröter
S. Baur
M. Walz
Teleradiology applications with DICOM-e-mail
Received: 29 December 2005
Revised: 18 July 2006
Accepted: 22 August 2006
Published online: 10 October 2006
# Springer-Verlag 2006
M. Walz
Medical Office for Quality
Assurance in Radiology,
Hessen, Germany
G. Weisser (*) . S. Ruggiero . A. Runa
Department of Clinical Radiology,
University Hospital Mannheim,
Theodor-Kutzer-Ufer 1-3,
68167 Mannheim, Germany
e-mail: [email protected].
uni-heidelberg.de
URL: www.teleradiologic-rnd.de
U. Engelmann
Division of Medical
and Biological Informatics,
German Cancer Research Center,
Heidelberg, Germany
A. Schröter
CHILI GmbH,
Heidelberg, Germany
S. Baur
Curagita AG,
Heidelberg, Germany
Abstract For the connection of
several partners to a Dicom-e-mail
based teleradiology network concepts
were developed to allow the integration of different teleradiology applications. The organisational and
technical needs for such an integration
were analysed. More than 60 institutions including 23 hospitals in the
Rhein-Neckar-Region, Germany were
connected. The needed functionality
was grouped in six teleradiology
applications (emergency consultation,
tele-guided examinations, expert consultations, cooperative work, scientific
cooperations and homework with on
call services) and their technical and
organisational needs according to
availability, speed of transfer, workflow definitions and data security
needs was analysed. For the local
Introduction
E-mail is one of the most important Internet services.
Leading e-mail service providers report more than 100
million users each [1]. E-mail is platform independent,
easy to use and serves an excellent interoperability.
Therefore it is frequently used for communication in the
medical community and most physicians have access to
e-mail communication. In many cases e-mail communication is the only way to transfer digital data between
hospitals without media exchange. In most institutions,
integration of teleradiology services
the setup and workflow is presented
for a standalone teleradiology workstation and a server based teleradiology gateway. The line type needed for
different groups of applications and
users is defined. The security concept
and fallback strategies are laid out,
potential security problems and
sources of errors are discussed. The
specialties for the emergency teleradiology application are presented. The
DICOM-e-mail protocol is a flexible
and powerful protocol that can be used
for a variety of teleradiology applications. It can meet the conditions for
emergency applications but is limited
if synchronous applications like teleconferences are needed.
Keywords Teleradiology .
DICOM-e-mail . Telemedicine .
Internet
e-mail traffic is checked to prevent the transport of
malicious content into the internal networks.
If standard e-mail clients are used for the transfer of
personalized patient information additional measures are
needed to reassure data security and integrity. For the
transmission of radiological images the data files can be
added manually as attachments, followed by a PGP or
S/MIME e-mail encryption with free software plug-ins
[2]. However, the clinical use of such an encrypted e-mail
solution is diminished by the poor integration into the image
workflow. Additionally, many e-mail clients designed for
1332
“regular use” cannot properly handle large amounts of data as
required for the transmission of DICOM studies.
The DICOM protocol is the de facto communication
standard for the transfer of biomedical diagnostic and
therapeutic information between modalities and information systems inside a hospital [3]. The DICOM Supplement
54 [4], published in 2002, and the registered DICOM
MIME type allow the transfer of DICOM objects using
standard e-mail transport mechanisms.
The combination of such e-mails with additional encryption according to the OpenPGP standard is referred as
DICOM-e-mail in this article. The national German standard
for teleradiology as defined by the German Radiology
Society in 2004 is also based on this protocol [5–7]. DICOMe-mail is a legacy free protocol and allows the secure
exchange of DICOM images and other file based information using standard Internet connections and mailboxes.
To reassure ease of use and reliability and for integration
into daily routine automated converters and workstation
applications with the support of DICOM interfaces are
needed. To date seven commercial and three Open Source
products with the support of DICOM-e-mail areavailable [8].
Since 2002 the DICOM-e-mail protocol is in use in the
Rhein-Neckar region in Germany. A growing number of
hospitals and other institutions are part of the network
[9–11]. To date over 60 institutions have integrated the
DICOM-e-mail solution in their workflow.
The DICOM-e-mail teleradiology protocol is used in
different applications:
–
–
–
–
–
–
–
Emergency consultations
Tele-guided examinations
Cooperative work
Expert consultations
Scientific cooperation
Image and report distribution
On-call services at home
The aim of this project was the integration of different
teleradiology applications into the workflow of more than
60 partners. This article describes the analysis of the
organisational and technical needs for the different types of
teleradiology applications. It demonstrates the developed
concepts for an integration of DICOM-e-mail based
teleradiology services into the DICOM workflow inside a
hospital.
It points out advantages and disadvantages of the
DICOM-e-mail protocol based on the experiences of
three years of use.
Materials and methods
Protocol
The DICOM-e-mail protocol is described in detail in [6]. In
summary it is based on the exchange of standard e-mails
with an additional encryption according to the OpenPGP
standard [12, 13]. DICOM images are attached according
to the DICOM Supplement 54 [4], while other attachments
(text and graphic formats such as pdf, jpg, rtf, etc.) are
allowed, as long as they represent a valid MIME-type. The
built-in zip compression of the OpenPGP standard is used.
E-mail exchange is performed over standard e-mail server
protocols POP3, IMAP4 and SMTP.
Test equipment
For the performance tests the following data and installations were used: Test dataset CT head scan: 30 CT images
512 matrix, 2 scout images and a protocol image. The test
workstation was equipped with Pentium 4 2.6 GHz,
512 MB RAM, internal transfers using fast Ethernet
100 MBit, GnuPG 1.4.2, Thunderbird 1.0.6, and WindowsXP Pro SP2.
Network
The DICOM-e-mail network in the Rhein-Neckar-Triangle
consists of over 20 hospitals including four “level one”
trauma centres and 17 district and city hospitals [9]. It also
includes over 40 other neighboured partners such as private
practice radiologists, offices for quality assurance and
homework installations for radiologists in three German
states. The DICOM-e-mail network is currently being
extended into the state of Baden-Württemberg, where more
than 50 hospitals will be included in 2006.
Project group
The discussion of the technical and organisational needs
was based on a previous survey [14, 15]. The necessary
updates and details were discussed and fixed within the
project group, which consisted of the central project leader
and 12 local project leaders together with a number of
physicians from the participating hospitals.
Teleradiology applications
Different teleradiology applications were needed within the
network; they cover most of the possible applications
including [16, 17]:
1. Emergency consultations (neurosurgery, neurology,
neuroradiology, heart surgery, orthopaedic surgery)
2. Tele-guided examinations (without a radiologist at the
location of examination)
3. Expert consultations (oncologic surgery, abdominal
surgery)
1333
4. On-call services at home for radiologists
5. Cooperative work (for example, cardiology and heart
surgery in different hospitals, exchange of image data
between hospitals and private practice radiologists,
exchange of data for quality assurance measures)
6. Scientific cooperation between university hospitals,
universities and research centers
7. Image and report distribution
8. Integration of images and reports into an electronic
patient record (EPR)
9. Demonstration of image data and online-conferences
10. External archiving services
Results
The data presented is a result of the use of the described
technology in the Rhein-Neckar region in southwest
Germany.
Technical and organisational needs
The project group defined the six main applications
required in the network and analysed them for their
technical and organisational needs.
The topics were the availability and stability of the
teleradiology systems, the needed speed of transfer for a
complete examination, the need of a detailed workflow
definition between all partners for that specific application
and the level of data security needed for these applications
(Table 1).
For emergency consultations availability and speed of
transfer are the crucial points. Since there are a lot of ad hoc
transfers with direct personal communication between the
partners the workflow definition often is of minor interest.
For tele-guided examinations availability and speed of
transfer are of high importance. Workflow definitions are
essential to reassure the quality of the examinations, where
no radiologist is present at the location of the examination.
For homework the availability was regarded as partially
less important because of the possibility of returning to the
hospital in case of a failure of the teleradiology connection.
Table 1 Relevance of parameters (needs, requirements) for
different teleradiology
applications: +++ (very important), ++ (important), + (less
important)
The data security was regarded as very important for all
applications with the use of personalized patient data. It
was regarded as “less important” for scientific cooperation
because only anonymized or pseudonymized data is used
for these transfers of image data. Some consultations of
experts is also done with anonymized or pseudonymized
patient data.
Local integration of teleradiology services
The communication partners represented a wide range of
different infrastructures (no PACS, PACS from various
different vendors, DICOM workstations from different
vendors). All CT scanners and MR scanners were DICOM
compatible. Three different types of integration of DICOMe-mail based teleradiology services were used for these
institutions:
–
–
–
Standalone teleradiology workstation or DICOM
workstation with integrated teleradiology functionality
Server based teleradiology gateway
Upgrade of an existing DICOM workstation with a
DICOM-e-mail converter service
Standalone teleradiology workstation
The easiest way to connect to the DICOM-e-mail
teleradiology network for partners without an existing
PACS and without a DICOM workstation is a dedicated
workstation with built-in support for the DICOM-e-mail
protocol (Fig. 1). Such a workstation can be addressed by
any DICOM modality and allows the viewing and
reporting of the received images. For data delivery, the
studies or images of interest can be selected, text
information can be entered and additional data such as
JPG images or PDF files can be attached to the DICOM
images. The whole dataset will be converted to encrypted
E-mails and sent to the corresponding partner. The
teleradiology images received are displayed in the normal
patient list, related information such as JPG or PDF files
can be viewed together with other patient data.
Application
Availability
Speed of image
study transfer
Workflow
definition
Data
security
Emergency consultation
Tele-guided examinations
Expert consultations
Cooperative work
Scientific cooperation
Homework
(on call services)
+++
+++
+
++
+
+/++
<10 min
<10 min
<1 h to 1 day
<1 h to 1 day
<1 h to 1 day
<10 min
++
+++
+
++
+
++
+++
+++
++
+++
+
+++
1334
Fig. 1 Integration of a DICOMe-mail teleradiology workstation
This type of teleradiology integration usually requires an
additional manual user interaction for sending images over
the teleradiology network (manual selection of the images
and of the corresponding partner).
The reception of images is usually done automatically by
the workstation: polling the mail server, decryption of data,
checking of signatures, detachment of attachments, storing
of original DICOM data in the local database and perhaps
auto routing to another DICOM target. Some vendors offer
integrated auto routers which send incoming DICOM data
automatically to another site depending on certain rules,
such as DICOM port, AET, day of the week or even time of
day.
Server based teleradiology gateway
Integration of the DICOM-e-mail solution into a DICOM
workflow with or without a PACS can be seamless using an
Fig. 2 Integration of a DICOMe-mail gateway into the internal
DICOM workflow shown in the
‘send’ direction. The ‘receive’
direction is identical to the
process in Fig. 1
automatic DICOM-e-mail gateway (Fig. 2). This gateway
is addressed like any other DICOM device with DICOM
send. Unfortunately the DICOM protocol does not include
a forwarding procedure, any DICOM device is regarded as
an endpoint. A DICOM network device is defined by three
parameters: network port, network IP-address and Called
Application Entity Title (AET). One solution to enable
forwarding of DICOM images over the gateway from any
standard DICOM device is to use the CalledAET to define
the final destination of sent images. The DICOM receiver
of the gateway is listening to a specific port and IP-address
and will interpret the CalledAET given by the sending
DICOM device. For each communication partner a
different CalledAET will be used. Inside the gateway the
relationships between these AETs and the corresponding
e-mail addresses and public keys needs to be defined. This
can be done with a local lookup table or using a LDAP
server. Then all DICOM images received by this gateway
for a certain AET will be automatically converted into mail
1335
attachments, encrypted with the corresponding public key
and sent to the corresponding mail address. This method
enables an automatic DICOM to DICOM-e-mail gateway
for sending images out of the hospital without manual
interaction and can be used for an unlimited number of
partners.
Receiving DICOM-e-mails is similar. The teleradiology
gateway can be configured for different users with their
own mailboxes and private keys, e.g. neurosurgery,
radiology and neurology. The gateway will periodically
check all mailboxes and fetch all mail. The DICOMe-mails are decrypted automatically (with the private keys
stored in the local key ring) and the DICOM objects are
routed to a user specific workstation, the PACS or both.
Any other attachments such as JPG or PDF files can be
forwarded to an in-house mail server as unencrypted mail.
Commercial gateways also allow the integration of these
non-DICOM attachments into the DICOM workflow using
a web server. DICOM images and non-DICOM attachments are joined with these solutions, as long as they are
encoded using the X-tags according to the German national
DICOM-e-mail standard [5, 6].
Therefore, integration of the DICOM-e-mail protocol
using an automatic gateway is possible as long as the
modalities, workstations and the PACS support the standard DICOM protocol. Usually no additional manual
interaction is needed. Complete software solutions with
this functionality are available as Open Source as well as
commercial implementations [8, 18, 19].
of the workstation software used for in-house DICOM
transfers.
Security concept
Public key infrastructure
The secret keys are not linked to a person but to specific
computer hardware. Within the network all GnuPG key
pairs are generated by the local system administrators or by
the field engineers of the software vendors. The secret keys
are stored locally, the public keys are forwarded to all
partners in the network.
Mail server communication
Even though all transferred e-mails are encrypted an
additional line encryption is used for the communication
between the e-mail-clients and the mail servers; therefore,
the encrypted variants of the mail protocols, POP3/S,
IMAP4/S and SMTP/S are used. In addition the SMTP
authentication according to RFC 2554 is used [20] and the
mail relay is deactivated for two of the three central mail
servers used for emergency teleradiology. Therefore only
users with an account on the same mail server are able to
send e-mails to the other partners. These two mail servers
block Internet e-mail from general e-mail accounts. Every
partner in the network can be reached by Internet mail over
the third mail server.
Upgrade of an existing DICOM workstation
with a DICOM-e-mail converter service
Fall-back strategies
Virtually any existing DICOM workstation can be used for
DICOM-e-mail if the basic DICOM to DICOM-e-mail
converter software is installed on the same computer (if
allowed by the vendor of that workstation). Since converter
software is available for all major operating systems and
communication between the converter software and the
DICOM workstation software is based on internal TCP/IP
communication this solution should work with any
available DICOM workstation. To receive DICOMe-mails the converter software will check the mailboxes
periodically, poll the e-mails, decrypt them and send them
via DICOM to the workstation software over the internal
TCP/IP connection.
To send DICOM-e-mails the required partner information (e-mail addresses, GPG key ID, CalledAET) has to be
configured in the converter software and their public keys
have to be imported. The converter software will start a
DICOM receive service for the communication with the
workstation software. For each partner a DICOM entry is
then added in the workstation software. Now images can be
sent to each teleradiology partner using the same workflow
Each teleradiology client has e-mail accounts on all three
central mail servers to receive images. These three
mailboxes are all checked periodically. The content of
these mailboxes is not synchronized between the mail
servers; the mail servers are running independently. In case
of a malfunction of one of the mail servers a sending
teleradiology client can therefore switch to the mailbox of
another mail server to reach the recipient. Some of the
commercial clients allow the assignment of multiple
mailboxes to a recipient and this switching between the
three mailboxes is done automatically without user interaction. In the Open Source solutions a repeated manual
sending of the images to the other mail server is needed, if a
transfer to one mail server failed. One of the central mail
servers does provide a dial-in router for ISDN lines in
addition to its Internet connections. This is used by some
clients for a fallback in case of a failure of the local Internet
line. The teleradiology client also manages this fallback
between Internet line and ISDN dial-in automatically
without user interaction.
1336
Local handling of e-mails
Transmission mode
In the four major hospitals the DICOM-e-mail gateways
were equipped with antivirus software to check all
attachments. Due to the encrypted content the central
standard mail gateways from the university hospitals are
not able to do this check during the forwarding process.
The DICOM-e-mail protocol allows single or multiple
attachments. Thus, some of the available clients sent the
DICOM test study as a single e-mail with 33 attachments
while other clients generated 33 separate e-mails with
single attachments. This results in a different transfer
process (Fig. 3).
The slowest process, the e-mail sending process,
dominates the total speed of transfer. The interleaved
transport is about 10% faster and the first image is viewable
after less than 10 seconds, compared to 2 minutes when
using the blockwise protocol.
Running the converter software on current hardware, the
encryption and decryption processes for large datasets are
about 50 times faster than the send process for this dataset
using the standard connection speed for a peripheral
hospital with ADSL lines (256 kBit). Even with 2 MBit
SDSL lines the encryption and decryption processes cause
no relevant delay. Therefore the selection of the hardware
for DICOM-e-mail converters is not critical.
Measures for availability
All partners use at least two mailboxes on different mail
servers. The emergency accounts of the major hospitals use
three different mailboxes, which are polled automatically.
The clients and gateways within the hospitals always pull
all mail accounts; therefore, the failure of a single mail
server can be overcome using another mail server to send
the images. There is no duplication of mail between the
mail servers.
Speed of transfer
To define the needed bandwidth for the applications
mentioned the process of sending images with the
DICOM-e-mail protocol was analyzed (Table 2).
The image files received are stored on the workstation as
DICOM objects and converted into e-mail attachments.
This conversion increases the size by 15% due to the
limited character set used within e-mails. During the
encryption process the built-in zip compression decreases
the size of the files, the resulting size of the dataset is about
24% lower than the original size. These values differ
depending on the image content.
Table 2 Analysis of the transfer
process using the DICOMe-mail-protocol; dataset and
workstation as described in the
Materials and methods section.
One image per email was used
DICOM transfer modality
to workstation
Conversion to e-mail (7 bit)
Encryption
Compression
Sending e-mail 256 kBit/s
1024 kBit/s
Polling e-mail (100 Mbit/s)
Decryption and
decompression
Total 256 kBit/s Send
1024 kBit/s Send
Line types
Analysis of the regional communication partners according
to their needs for teleradiology communications (as defined
by the six different applications) led to four different
groups of partners (Table 3). To define the appropriate
connection type the communication needs must be
separated into upload and download directions. The
affordable ADSL connections are restricted to very limited
upload speeds (128 kBit for the standard connection). Due
to the fast download speed they can be used for homework
(like radiologists on call at home), and even for urgent
examinations. Partners with frequent and urgent uploads
(like peripheral hospitals with a need for neurosurgical and
neurological expert consultations and in-house CT scan-
Size per image
[kByte]
Size dataset
[kByte]
Elapsed time
[min:sec]
Speed
[kByte/sec]
516
16,624
00:04
4,200
590
407±41
328–467
407
18,999
12,604
00:03
00:09
5,600
1,400
12,604
407
516
12,604
16,624
07:30
01:54
00:03
00:02
28
111
3,800
7,900
07:33
01:57
28
103
1337
Fig. 3 Blockwise vs. interleaved DICOM-e-mail protocol.
Left: block-wise transport,
waiting for end of DICOM
association, single e-mail with
33 attachments. Right: interleaved transport, processing of
each DICOM file after storage,
33 e-mails with single
attachments
ners) are forced to use ADSL lines with boosted upload
rates (up to 384 kBit) or switch to SDSL or cable
connections. For major hospitals (e.g. the four “level one”
trauma centres in the region) which do provide expert
services for the peripheral hospitals and use the Internet for
teleradiology services for their consultants on call, a cable
connection with large upload and download bandwidth to
the teleradiology mail servers and the in-house clients is
needed and fallback strategies are recommended.
Table 3 Recommended line types for the different communication
partners in the regional network. For private practice radiologists
using the teleradiology system for image and report distribution to
their clinical partners the upload rate is frequent; otherwise, the use
of the system is rare for both directions for these partners
Homework
(on call services)
Peripheral hospital
Download Upload
Urgency
Frequent
Rare
Frequently urgent ADSL 1–3 MBit
Rare
Frequent
Frequently urgent SDSL 1–3 MBit, ADSL with
increased upload speed of >256 kBit
Frequently urgent Cable connection >=10 MBit
SDSL >=2 MBit
Major hospital, trauma Frequent
center
Private practice
Rare
radiologist
Referring physicians
Frequent
Frequent
Line type recommended
Fallback line
Different DSL provider
or ISDN
ISDN >=128 kBit
Rare/Frequent Rarely urgent
ISDN or ADSL
None
Rare
ISDN or ADSL
None
Rarely urgent
1338
Discussion
Teleradiology applications
The vast majority of the teleradiology applications (eight
out of the nine teleradiology applications mentioned in the
Materials and methods section) are realized in the
teleradiology project in the Rhein-Neckar region using
the DICOM-e-mail teleradiology protocol. To support all
applications and reach all partners in the network only one
outgoing connection to the central mail servers is needed.
No incoming connections and no open ports at the hospital
firewalls are needed. This protocol proved to be fast,
reliable and secure.
The missing application “demonstration of image data
and online-conferences”, e.g. using screen synchronisation
or mouse pointer synchronisation is not possible using this
protocol due to its asynchronous setup. Since only a very
limited number of partners demanded this functionality it
was subsequently incorporated with vendor dependent
protocols and was therefore available only to the users of
this software in the network. This functionality requires a
direct connection of the two partners; additional changes in
the corresponding hospital firewalls are necessary with IP
ports open to the Internet or the setup of a virtual private
network VPN.
There are also platform and vendor independent
protocols available for basic screen synchronisation (like
Virtual Network Computing VNC, http://www.realvnc.
com), but they also need the setup of a direct connection
between the synchronised partners.
The asynchronous setup is a distinct advantage in the
communication between partners such as private practice
physicians because sending images to a partner is still
possible even with a disconnected or turned off receiver
system (many computer systems in private practice are
turned off regularly during evenings or weekends). Therefore images and reports distributed to a private practice
physician can be collected by his DICOM-e-mail client
during the time it is able to connect to the mail server.
Local integration of teleradiology services
The integration into almost any DICOM based environment is possible using the commercial or Open Source
DICOM-e-mail solutions. Gateways allow a flexible and
customized image and information distribution of the
received data within the local network. Currently seven
companies do provide DICOM workstations or gateways
with built-in support of the DICOM-e-mail protocol as
described in this article, the latest list of vendors can be
viewed online [8]. Since a viewing station for medical
images needs to follow the European laws about medical
products [21] an Open Source package for a DICOM
viewing station with DICOM-e-mail support cannot be
offered by the developers. Nevertheless the combination of
available Open Source DICOM viewers and the Open
Source converter software is possible by the user, e.g. a
local system administrator in a hospital.
Additional partners and services
Due to the single-point network access the integration of
additional partners is simple and the setup of one gateway
allows the connection to each partner. Therefore duties like
the routine transfer of images to the state Medical Offices
for Quality Assurance can be switched to filmless and
medialess data transfers with minimal effort. This is
already working for the state of Hessen and is in progress
for the state Baden-Württemberg in Germany. It can help to
reduce costs of labour in the hospitals and offices. The
integration into routine system checks and maintenance
procedures is also possible.
The connection to other teleradiology-networks with
different techniques can also be achieved by using a single
gateway. This was realized to connect a VPN based
network with six district hospitals and one university
hospital to the existing DICOM-e-mail network. A single
DICOM-e-mail to DICOM gateway in the university
hospital was able to route the traffic between the
DICOM-e-mail partners and the hospitals within the
VPN network in both directions. No additional software
was needed inside the VPN network to allow point to point
data transfer between all partners in both networks.
The protocol allows the secure transfer of all file types.
Therefore it can be used to connect to other telemedicine
projects such as electronic patient records or to deliver
other medical data between partners without the setup of
additional software or gateways.
Security concept
Since the communication does make use of standard
Internet connections there are some potential security
problems:
1.
2.
3.
4.
Receiving unwanted mail (spam mail)
Receiving malicious content (virus mail, Trojans)
Eavesdropping of mail
Denial of Service DoS attacks to the public mail
servers
If all mentioned measures of security are combined
(content encryption, SSL protocols only, user authentication, dedicated mail servers, no mail received over relays),
then the level of security is comparable to a Virtual private
network. In such a closed network the security problems 1,
2 and 3 are very unlikely. To reassure the availability of the
mail servers (and prevent security problem 4) the mail
1339
servers are protected by firewalls, and a professional server
support company handles updates and patches.
Some partners of the teleradiology project in the RheinNeckar region were not able to connect directly to the mail
servers using the SMTP/S and IMAP/S protocols. Their
security guidelines or their Internet service providers only
allowed access to their own SMTP gateways. The integration of these partners was achieved by accepting mail relays
in one of the three central mail servers. Since this mail
server accepts any mail sent to the correct address by
standard Internet mail servers, spam and virus mail is
possible. All clients in use would ignore spam or virus mail
since the clients automatically process only encrypted
content. Nevertheless we did not register a single incorrect
e-mail in 2 years of use with more than 20 partners. This
may be due to the fact that the e-mail addresses are not
available to the public, they are exchanged from person to
person or via the project administrators. All available
clients do not execute any e-mail content; therefore, Trojans
and viruses are unlikely to be harmful in this environment.
Sources of errors
During the last three years with more than 1,000,000
e-mails transferred different errors were encountered. In the
initial phase, human errors (e.g. wrong use of the software,
selection of wrong partner entries, switching off parts of the
teleradiology systems by accident) dominated over technical errors (hardware or software failure such as power
supply crashes, crashing client software or system
processes due to corrupt mails). The human errors can be
lowered substantially by an integration of the teleradiology
solution into daily routine workflow. Therefore the optimal
solution is a PACS or PACS-workstation with built-in
teleradiology functionality. Such installations can be
used for the daily routine work of the radiologist and
teleradiology as well.
Written workflow definitions available at the workstation and regular on-site training are also needed to
reduce human errors.
account. The technical equipment should be upgraded to
failsafe versions. The bandwidth of the Internet connections should be at least 256 kBit (if solely used for
teleradiology) or higher (if used concurrently or if radiological examinations with many images are frequently
transferred). Using affordable high-bandwidth Internet
lines with 2 MBit the majority of transmissions are
completed in less than one minute; therefore, lossy
compression [22, 23] or the selection of key images [24]
is not needed.
An interleaved transmission process with single attachments should be used to reassure the visibility of the first
images as soon as they are received and before the
transmission process for the whole examination is
completed. The interleaved transmission process uses one
attachment per e-mail only.
The workflow should be simple and solutions with
integration into the daily routine workflow are preferred.
The availability of clients and servers should be monitored
continuously to prevent malfunctions prospectively.
One disadvantage of the DICOM-e-mail protocol is the
approximately 20% lower transmission speed due to the 7
bit e-mail-conversion compared to direct DICOM connections. Nevertheless the bandwidth can be upgraded more
easily compared to other solutions and the resulting speed
of inexpensive ADSL lines is much higher compared to
affordable dial-up lines.
Conclusion
The DICOM-e-mail protocol is a flexible and powerful
protocol that can be used for a variety of teleradiology
applications. It can meet the conditions for emergency
applications but is limited if synchronous applications like
teleconferences are needed. The presented concepts allow
the integration of this protocol into various environments.
Its use is cost effective, setup is simple and a wide range of
software applications compatible to the standard is
available, including Open Source solutions.
Acknowledgment This work was partially supported by the
Zukunftsoffensive III of the Social Ministry of the state of BadenWürttemberg, Germany.
Emergency teleradiology
If the DICOM-e-mail protocol is used for emergency
teleradiology some general aspects need to be taken into
References
1. Emailaddresses.com (2005) Overview
e-mail services. http://www.
emailaddresses.com/email_market_
size.htm. Cited 11 May 2005
2. Bergh B, Schlaefke A, Pietsch M,
García I, Vogl TJ (2003) Evaluation of
a “no-cost” Internet technology-based
system for teleradiology and co-operative work. Eur Radiol 13:425–434
3. Mildenberger P, Eichelberg M, Martin
E (2002) Introduction to the DICOM
standard. Eur Radiol 12:920–927
1340
4. DICOM Standards Committee (2000)
DICOM supplement 54 (DICOME-mail). http://medical.nema.org/
DICOM/supps/sup54_pc.pdf. Cited 07
September 2005
5. Mildenberger P, Kämmerer M,
Engelmann U, Ruggiero S, Klos G,
Runa A, Schröter A, Weisser G,
Walz M, Schütze B (2005) Teleradiologie mit DICOM E-Mail:
Empfehlungen der @GIT. RoFoFortschr Rontg 177:697–702
6. Weisser G, Walz M, Ruggiero S,
Kämmerer M, Schröter A, Runa A,
Mildenberger P, Engelmann U (2006)
Standardization of teleradiology using
DICOM-e-mail: recommendations of
the German Radiology Society.
EurRadiol 16(3):753–758
7. Engelmann U, Schütze B, Schröter A,
Weisser G, Walz M, Kämmerer M,
Mildenberger P (2005) DICOM-e-mail:
the German minimal standard for teleradiology. In Lempke HU, Inamura K,
Doi K, Vannier MW, Farman AG (eds).
Proceedings of the 19th international
congress and exhibition computer assisted radiology and surgery CARS
2005. Amsterdam: Elsevier pp 926–931
8. Arbeitsgemeinschaft Informationstechnologie (2005) List of vendors supporting DICOM-e-mail. http://www.
tele-x-standard.de/html/mitglieder.html.
Cited 22 December 2005
9. Homepage of the Teleradiology Project
Rhein-Neckar-Triangle, Germany
(2005) Das Teleradiologie-Projekt
Rhein-Neckar-Dreieck. http://www.
teleradiologie-rnd.de. Cited 16
September 2005
10. Engelmann U, Schroeter A, Schweitzer
T, Meinzer HP (2002) The communication concept of a regional stroke
unit network based on encrypted image
transmission and the DICOM-mail
standard. In: Lemke HU, Vannier MW,
Inamura K, Farman AG, Doi K, Reiber
JHC (eds). CARS 2002. Heidelberg:
Springer 612–617
11. Weisser G, Walz M, Koester C, Dinter
D, Duber C (2002) New concepts in
teleradiology with Dicom e-mail.
Biomed Tech 90(5):356–359
12. OpenPGP Alliance (2005) The
OpenPGP Alliance homepage. http://
www.openpgp.org. Cited 07
September 2005
13. Network Working Group (1998)
RFC2440: OpenPGP message format.
http://www.ietf.org/rfc/rfc2440.txt.
Cited 07 September 2005
14. Walz M, Bolte R, Lehmann KJ,
Hothorn T, Brill C, Hotohorn L (1997)
ANARAD: Requirements to teleradiology from Germans users point of
view. In: Lemke HU, Vannier MW,
Inamura K (Eds). Computer Assisted
Radiology and Surgery (CAR 1997),
Elsevier, Amsterdam, 615–620
15. Walz M, Klose KJ, Wein B (1999)
Bericht zu Teleradiologie-Aktivitäten
und -Ergebnissen der ANARAD-Studie
und AGIT. RoFo-Fortschr Rontg 170:
M 107–110
16. Walz M, Brill C, Bolte R, Cramer U,
Wein B, Reimann C, Haimerl M,
Weisser G, Lehmann KJ, Loose R,
Georgi M (2000) Teleradiology requirements and aims in Germany and
Europe: status at the beginning of 2000.
Eur Radiol 10:1472–1482
17. Lienemann B, Hodler J, Luetolf M,
Pfirrmann CW (2005) Swiss teleradiology survey: present situation and
future trends. Eur Radiol 15:2157–2162
18. University Hospital Mannheim (20059
Link to DICOM-e-mail OpenSource
software: http://www.teleradiologiernd.de/eng/tr-rnd_osource.html. Cited
28 November 2005
19. University Hospital Mainz, Germany
(2005) Link to DICOM-e-mail OpenSource software. http://www.tele-xstandard.de/html/download_disclaimer.
html. Cited 28 November 2005
20. Network Working Group (1999)
RFC2554: SMTP service extension for
authentication. http://www.ietf.org/rfc/
rfc2554.txt. Cited 07 September 2005
21. European Commission (1998) Medical
device directive (MDD) 93/42/EEC
22. Parisi SB, Mogel GT, Dominguez R, Dao
H, Cramer TJ (1998) The effect of 10:1
compression and soft copy interpretation
on the chest radiographs of premature
neonates with reference to their possible
application in teleradiology. Eur Radiol
8:141–143
23. Bergh B, Schlaefke A, Frankenbach R,
Vogl TJ (2004) Remote access to a
web-based image distribution system.
Rofo 176:896–901
24. Ludwig K, Bick U, Oelerich M,
Schuierer G, Puskas Z, Nicolas K,
Koch A, Lenzen H (1998) Is image
selection a useful strategy to decrease
the transmission time in teleradiology?
A study using 100 emergency cranial
CTs. Eur Radiol 8:1719–21