CP 13-2

Transcription

CP 13-2
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION
CP 13-2
In re: 16 CFR § 1051 Petition for Rulemaking
Eliminating Accessible Cords
On Window Covering Products
Petitioners:
Parents for Window Blind Safety,
Consumer Federation of America,
Consumers Union,
Kids in Danger,
Public Citizen,
U.S. PIRG,
Independent Safety Consulting,
Safety Behavior Analysis, Inc.,
Onder, Shelton, O'Leary & Peterson,
PETITION FOR RULEMAKING
Petitioners, Parents for Window Blind Safety, Consumer Federation of America,
Consumers Union, Kids in Danger, Public Citizen, U.S. PIRG, Independent Safety Consulting,
Safety Behavior Analysis, Inc., and Onder, Shelton, O'Leary & Peterson, LLC (hereinafter
"Petitioners"), pursuant to 16 CFR § 1051 state to the U.S. Consumer Product Safety
Commission as follows:
INTRODUCTION
The U.S. Consumer Product Safety Commission (hereinafter "CPSC") has long
recognized window covering cords as a hidden strangulation and asphyxiation hazard to
children and today continues to include it as one of the top five hidden hazards in the home.
(CPSC, 2007, CPSC 2013a) Since 1985, the CPSC has worked with and repeatedly pressed
the window covering industry (hereinafter "Industry") to eliminate these hazards, through
public education, multiple corrective actions, and the voluntary standards development
process. Despite these efforts, the voluntary standard (first passed in 1996 and most recently
revised in 2012) remains inadequate and continues to permit window coverings with
hazardous accessible cords that injure and kill young children.
The unresolved issue of window covering cord injuries and deaths is not limited to
the United States. Indeed, global frustration over this on-going hazard resulted in the June
15, 2010 joint action by the CPSC, Health Canada and the European Commission wherein
they joined together "in agreement on the need for immediate action," and made a trilateral
request to the Industry for "support [of] a swift and comprehensive process that concurrently
eliminates the risk factors causing deaths and injuries from all types of corded window
covering products." (CPSC, HC, DO SANCO, 2010)
Acting upon the trilateral request, the Window Covering Manufacturers Association
(hereinafter "WCMA") undertook a fifth revision of the voluntary standard, ANSVWCMA
A100.1 American National Standard for Safety of Corded Window Covering Products.
When it appeared that the renewed standards writing efforts were not satisfactorily addressing
the major hazards responsible for injury and death, CPSC Chair Inez Tenenbaum wrote to the
Industry on June 1, 2011, re-invoking the international call for a standard that eliminates
window covering hazards, and stating, "I reaffirm to you my call for a comprehensive revised
voluntary standard that eliminates- not just reduces- the strangulation risks from window
coverings." (CPSC, 2011a) Ultimately, the inadequacy of the voluntary standards process, as
well as the inadequate result toward which it was clearly heading, led consumer organizations
reluctantly to take the unusual step ofwalking out of the process. (CFA 2011)
Indeed, the call for a standard that would finally eliminate window covering hazards
was disregarded. The voluntary ANSI standards development process failed again, when the
fifth revision ofthe ANSIIWCMA A100.1 standard was approved in late 2012 with critical
inadequacies. As will be shown below, 28 years after the CPSC first began working with
Industry to address these hazards, the latest version of the standard still does not eliminate the
major hazards that have caused approximately 40 percent of the deaths and injuries that have
occurred since 1996. In fact, the new standard allows for increasing numbers of hazardous
accessible cords to be loaded onto new window coverings. If the ANSVWCMA A100.1
voluntary standard is allowed to stand as the de facto industry safety standard, children will
continue to strangle and asphyxiate on unsafe corded window covering products. ·
Due to Industry's failure to develop a standard that adequately mitigates the risk of
strangulation on corded window coverings, the Petitioners hereby formally Petition for
Rulemaking under the authority and process set forth in 16 CFR § 1051, et seq. and request
the Commission to promulgate a mandatory standard that prohibits any window covering
cords where a feasible cordless alternative exists, and for those instances where a feasible
cordless alternative does not exist, requires that all cords be made inaccessible through the use
of passive guarding devices.
HISTORY:
THE FAILURE OF THE VOLUNTARY STANDARDS PROCESS
1985 Safety Alert
Following the reporting of 41 deaths on window covering cords between 1973 and 1980
and an additional report of another 35 deaths between 1981 and 1984, the CPSC approached
Industry requesting its cooperative effort in issuing a joint Safety Alert. (CPSC, 1985a) CPSC
staff met with representatives of Industry on September 13, 1985 and presented a proposed
2
Safety Alert that made several recommendations including the cutting of cord loops. (CPSC,
1985b)
A joint Safety Alert was issued on December 20, 1985, but the recommendation to cut
cord loops was not included. In fact, Industry did not accept the recommendation to cut cord
loops for another nine years. The recommendations that were incorporated into the 1985 Safety
Alert were: I) Keep cords out of the reach of children and utilize safety devices such as cord
cleats; 2) Adjust cords to the shortest possible length for the application; and 3) Do not place
cribs or other furniture near windows, for furniture gives children added height to reach cords.
(CPSC, 1985c)
A year after the 1985 Safety Alert was issued, the WCMA created camera-ready
warnings incorporating some of these safety recommendations and made them available for use
by manufacturers as bottom rail labels, hang tags and warning sheets. (DWC, 1988) These
warnings were used from 1986 until the adoption of the first voluntary standard in 1996,
ANSVWCMA AIOO.l- 1996.
Warnings alone failed and children continued to be injured and killed:
1985:
1986:
1987:
1988:
1989:
1990:
1991:
1992:
1993:
II fatalities
9 fatalities
8 fatalities
8 fatalities
II fatalities
II fatalities
18 fatalities
19 fatalities
13 fatalities
2 non-fatalities'
0 non-fatalities 2
2 non-fatalities 3
0 non-fatalities 4
4 non-fatalities 5
I non-fatality 6
I non-fatality 7
0 non-fatalities 8
9
I non-fatality
1994 Cord Loops Efforts and Voluntary Corrective Action Plan
Faced with continuing deaths, the CPSC once again engaged Industry, requesting that
window covering hazards be addressed through design changes, including the elimination of
cord loops as CPSC first brought to Industry's attention in 1985.
In September 1994, Industry, through the newly-created Window Covering Safety
Council, (hereinafter "WCSC") agreed to enter into a CPSC Voluntary Corrective Action Plan
(hereinafter "VCAP") consisting of public education and outreach, retrofit product distribution,
and product design modifications eliminating looped outer cords on certain horizontal window
coverings. (WCSC, 1994) Simultaneously, Industry agreed to "look at future design changes to
all window covering products (i.e., multiple cord products, vertical, cellular and pleated designs)
to incorporate [CPSC] staff approved changes" and "to work under the auspices of ANSI to
formalize future design changes that incorporate safer design." (CPSC, 1994a)
In 1993 and1994, both the CPSC and Industry safety consultants had warned that
separating outer cord loops on some window coverings was not sufficient by itself to prevent
further fatalities and injuries. Both CPSC Human Factors evaluations of the proposed separated
tassel/safety tassel redesign, and private studies performed for manufacturers, indicated that
3
these limited redesigns would not eliminate cord risks or stop fatalities. (FAA, 1993; CPSC,
1994b; CPSC, 1994c; CPSC, 1994d; CPSC, 1994e) Industry was warned that pull cords would
re-tangle and knot with use, recreating the cord loop hazard. Similarly, Industry was advised
that single cords can wrap around a child's neck, resulting in serious injury or death.
Accordingly, the VCAP indicated that it was simply an "interim solution" until better technology
could be developed.
Industry codified the efforts of the VCAP into the voluntary standard, ANSIIWCMA
A 100.1-1996. The 1996 ANSI standard required the elimination of some outer cord loops,
which was accomplished by most manufacturers through the use of outer cords with separated
tassels and/or a breakaway safety tassel on limited types of window coverings. Also, tie-down
devices were required on continuous loop operating systems.
Further, leading up to the 1996 ANSI standard, by letter dated November 21, 1995, the
CPSC requested the new standard include warnings for not just outer cord hazards but inner cord
hazards, as well. (CPSC, 1995) Industry rejected CPSC' s recommendation to include a
pictogram educating consumers about the existence of hidden inner cords and failed to create a
design standard to prevent inner cord hazards. The only reference to inner cord hazards in the
1996 ANSI standard was the inclusion of a vague, unexplained warning statement about "cords
that run through window coverings" on temporary hang tags (that are removed upon
installation). The 1996 ANSI standard also did not address a number of other known hazards,
including the loops on larger window coverings with more than two outer cords, unnecessarily
long cords, multiple cord joiner hazards, exposed rear cords on roman shades, and lifting loops
on roll-up shades. The 1997 standard also failed to establish warnings for many hazards that
were not otherwise addressed.
As forewarned by the CPSC and safety experts, children continued to strangle on
window covering cords with unaddressed hazards; the death and injury toll continued to rise:
1994:
1995:
1996:
1997:
1998:
1999:
2000:
16 fatalities
14 fatalities
17 fatalities
16 fatalities
12 fatalities
7 fatalities
11 fatalities
1 non-fatality 10
4 non-fatalities 11
5 non-fatalities 12
3 non-fatalities 13
2 non-fatality 14
0 non-fatalities 15
. . 16
c:
5 non-1ata11t1es
2000 Inner Cord/Lift Cord Efforts
By letter dated September 3, 1999, CPSC staff wrote to Industry renewing its concern
regarding inner cord strangulation hazards, and pressed for action. Faced with 14 recent inner
cord deaths and one injury, the CPSC demanded that Industry also address the hazards associated
with inner cord loop formation through design. (CPSC, 1999)
In cooperation with the CPSC, Industry entered into a second Voluntary Corrective
Action Plan in September of2000, again involving public education and outreach, retrofit
product distribution, and new product modification. (WCSC, 2000a) Under this VCAP, inner
4
cord stops were placed on outer cords near the head rail to prevent the formation of an inner cord
loop. The retrofit and public education efforts renewed with the continued distribution of safety
tassels and continuous loop tie-down devices.
Industry's public education and outreach efforts have consistently included the WCSC's
website providing Industry safety recommendations adopted in 2000, including the
recommendation that consumers "install only cordless" window coverings in homes with young
children. (WCSC, 20II; WCSC, 2000b)
Industry's 2000 VCAP efforts were then codified into a 2002 revision of the voluntary
standard, ANSIIWCMA AIOO.l-2002. This revision ofthe standard continued to leave many
accessible window cords unaddressed.
The ANSIIWCMA AIOO.l Standard was again revised in 2007, and then again in 2009
and 20IO following extensive CPSC recalls for un-addressed hazards of rear inner cords on
roman shades and lifting loops on roll-up shades.
Piecemeal redesign, retrofit, warnings and public education efforts had limited success,
and the toll of injuries and deaths continued to rise:
200I:
2002:
2003:
2004:
2005:
2006:
2007:
2008:
2009:
20IO:
II fatalities
II fatalities
I7 fatalities
6 fatalities
9 fatalities
7 fatalities
9 fatalities
I7 fatalities
I4 fatalities
II fatalities
7 non-fatalities 17
9 non-fatalities 18
2 non-fatalities 19
4 non-fatalities 20
6 non-fatalities 21
4non-fatalities 22
3 non-fatalities 23
9 non-fatalities 24
30 non-fatalities 25
I4 non-fatalities 26
While governmental pressures mount, the voluntary standard remains inadequate
Due to the continued inadequacies of the voluntary standard, the U.S. and foreign
governments started to increase pressure on Industry. In the 20 I 0 trilateral letter referenced at
the start of this petition, the CPSC, Health Canada and the European Commission made clear
their directive to Industry that current voluntary standard provisions were not enough and
requested they "eliminate the risk factors causing deaths and injuries from all types of corded
window covering products."
In 20 I 0, safety experts and consumer organizations, including representatives from
Parents for Window Blind Safety, Independent Safety Consulting, Consumer Federation of
America, and Consumers Union, were for the first time allowed a limited role in the voluntary
standards writing process. All held out great hope for the voluntary process. However, one year
later, these safety experts and consumer representatives reluctantly walked out of a voluntary
standards meeting and removed themselves from this process, because Industry was ignoring
their recommendations and refusing to give them meaningful participation in the standards
5
writing process. (NYT, 2011)
During the standards writing process, it became clear that loopholes in the voluntary
standard were responsible for many injuries and deaths, but were not going to be addressed by
Industry. Accordingly, in an August 4, 2011 speech directed to Industry, CPSC Chair
Tenenbaum again called Industry to task, declaring, "It is time to 'eliminate' the strangulation
risk on window blind cords. Notice how I did not say, 'reduce the hazard,' I said eliminate the
hazard." (CPSC 2011b)
The Retailer Industry Leaders Association (hereinafter "RILA") was likewise alarmed,
and by letter dated September 12, 2011, urged Industry to adopt standards that eliminate
operational cords capable of forming hazardous loops and to address continuous loop tie-down
devices. RILA urged Industry to finally agree to address these hazards, requesting that the
WCMA "address concerns ofRILA, CPSC technical staff, and consumer advocacy groups as
you work to develop the improved standard." (RILA 2011)
CPSC Staff comments on the January 23, 2012 proposed version of the voluntary
standard primarily addressed the serious remaining risks associated with operating cords and
recommended the clear-cut solution of limiting the combined length of all accessible cords to no
longer than the neck circumference of the youngest child at risk regardless of the position of the
window covering (i.e., raised or lowered, opened or closed). However, as later noted by CPSC,
these comments were largely ignored in the final version of the standard: "the major hazards
associated with operating cords and looped cords remained the same as the originally proposed
version." (CPSC, 2012; CPSC, 2013)
When the ANSI/WCMA AlOO.l-2012 was approved on November 28,2012, yet again
this standard failed to adequately address the strangulation hazard posed by accessible cords on
window coverings. As further detailed below, the standard continues to permit window
coverings with hazardous accessible cords that injure and kill young children. After this
standard was promulgated, an analysis ofwindow covering incidents between 1996 (the date of
the first voluntary standard) and 2012 was conducted. The purpose of this analysis was to
identify both the cord characteristic of each window covering and the accident mechanism to
determine what cord characteristic was involved, in order to determine whether the 2012
ANSIIWCMA voluntary standard would have prevented the incident from occurring. Based on
this analysis, approximately 40% of incidents would not have been prevented. Further, the
2012 standard actually permits an increase in the number and types of hazardous accessible
cords on some newer window coverings.
And so, 28 years after Industry agreed to work with CPSC to address this hazard, and
having been given clear direction and multiple opportunities to develop a meaningful standard,
and having been duly warned of the inadequacies ofthe proposed standard, even this latest
version (the sixth attempt) ofthe ANSIIWCMA A100.1-2012 standard fails to eliminate or
adequately reduce the risk of injury and death from accessible window covering cords.
In April of 1994, manufacturer Comfortex Window Fashions foreshadowed what has
ultimately been borne out, namely that warning and redesign efforts will fail so long as they
involve accessible cords. Comfortex warned, "Until all window coverings are free of cords for
6
their operation, there will be no true safety if cords are available to small children." (Comfortex,
1994) Comfortex was right in 1994; those prophetic words have stood the test of time.
Recent injury data continues to reflect deaths and injuries from window coverings:
2011:
2012:
6 fatalities
5 fatalities
2 non-fatalities (data set incomplete) 27
I non-fatalities (data set incomplete) 28
MANDATORY RULEMAKING IS APPROPRIATE TO ELIMINATE ACCESSIBLE
CORDS ON WINDOW COVERINGS
By statute, efforts to address product hazards through voluntary consensus
standards are necessary before a mandatory standard can be promulgated. According to
CPSA Section 9(f)(3)(D), the promulgation of a mandatory standard is appropriate
when:
"(i) Compliance with such voluntary consumer product safety standard is not
likely to result in the elimination or adequate reduction of such risk of injury; or
(ii) It is unlikely that there will be substantial compliance with such voluntary
consumer product safety standard." (15 U.S.C. Section 2058)
Petitioners have carefully examined the injury and death data associated with
window coverings and the record of compliance with the voluntary standard, and find
that both of these criteria are met in the context of corded window coverings.
Failure of ANSI/WCMA AlOO.l-2012 to Eliminate or Adequately Reduce Risk
First, examination of available injury and death data reveals that a high number of
incidents since passage of the first standard in 1996 would not have been prevented by even the
most recent (2012) version of the ANSIIWCMA standard. (Exhibit 1) Of the total293 incidents
between 1996 and 2012, 250 had sufficient information available to make such a determination.
Ofthese 250 incidents, 102 ofthe injuries and deaths (approximately 40%) would not have been
prevented by the current voluntary standard, indicating that an unreasonable risk of injury on
corded window coverings continues to exist:
55
Incidents on manufacturer separated outer cords (both pull cords and tilt cords) that
caused injury or death via knotted/tangled loops, defective break-away devices, and cord
wrap-around.
29
Incidents on window coverings with looped outer cords but where the manufacturercreated loop did not cause the incident. These incidents involved either wrap-around
incidents or children caught in tangled/knotted loops.
7
5
Continuous loop cord incidents where a tension/tie-down device was present at the scene
but was either not installed, had pulled out of the wall, or had broken. (CPSC staff has
criticized the effectiveness of the active tension device provision, since it is foreseeable
that "tension devices may not be installed at all, uninstalled for some reason, or installed
incorrectly ... " and therefore, "the proper installation of tension devices, a critical
component for the safe use of the product, should not have to be done by consumers.")
(CPSC, 2012)
6
Other instances caused by a hazardous cord allowed by the standard - such as reverse
inner cord incidents and incidents where the victim was caught in a cord joiner loop
on a multi-corded window covering.
7
Incidents caused by the manufacturer's failure to make the product according to the
voluntary standard in effect at time of manufacture.
Second, even though Industry had already developed cordless window coverings in 1996,
and by 2000 was recommending cordless window coverings for families with young children, the
voluntary standard still allows corded window coverings.
Third, some manufacturers have taken advantage of weaknesses in the standard to
actually increase the number and types of long, accessible cords on newer window coverings,
thereby making blinds more hazardous than ever. For example, CPSC In-Depth Investigation
(IDI) 120727CCC290 involves the 7/10/12 death of a 3-year-old girl who strangled when she
wrapped the tilt cord of a 20 I 0 faux wood horizontal blind around her neck. The blind was
manufactured by a large, well-known window covering manufacturer, and was sold and installed
by a major home-improvement retailer. Not only does this blind have the hazards of most
corded window blinds, such as long pull cords, but it also has a number of newer and
functionally unnecessary hazards allowed by the 2012 WCMN ANSI standard. This blind is
more dangerous than traditional corded blinds in at least five different ways:
•
It has 2 tasseled tilt cords instead oftraditional tilt wand to rotate the slats of the
blind. This extra set of cords puts hazardous accessible outer cords on both the left
and right side of the blinds (as opposed to only one side with standard pull cords).
• It has unnecessarily long tilt cords that are 2/3 the window's height, even though only
a few inches of cord are needed to perform the tilt function.
• It has large flat-topped tassels that are more likely to snag/catch on a single cord
wrapped around a child's neck to create deadly loop, and have been implicated by the
CPSC in-depth-investigation as a cause ofthis 7110112 death and at least one other
death {080915HNE3763).
• It has "inner cords" strung along the outside of both front and back of the blind,
instead of through holes in the center of the slats, that are more accessible and
attached in a less secure manner. This style of 'inner cords strung on outside of blind'
was involved the 10/4/11 death of a child on a 2009 blind (CPSC IDI
111018CCC2027).
• It has doubled the number of pull cords used on each blind, because the traditional
single inner cord that run through the slats was replaced with two cords, at both front
and back of the slats.
8
Instead of this blind having two traditional outer cords and a tilt wand, it has six long
outer cords, each with a large flat top tassel, that tangle easily, and has moved the inner cords
from inside slats to the far more accessible, outside front and back locations. This example
illustrates how the voluntary standard does not prohibit Industry from actually increasing the
number of hazardous accessible window covering cords.
In all of these respects, the voluntary standard fails to eliminate or adequately reduce
the unreasonable risk of injury or death associated with accessible cords on window
coverings.
Lack of Substantial Compliance with Voluntary Standards
There is substantial non-compliance with the voluntary standard. A number of
manufacturers have ignored basic safety provisions of the voluntary standard, and have
manufactured non-compliant window coverings for years and even decades. Since 2007, there
have been at least 16 CPSC recalls involving blinds that were not manufactured in compliance
with the voluntary standard.
Disturbingly, most of these instances of non-compliance (13 of 16) appear to have been
discovered unintentionally as a by-product ofCPSC's 2008-2010 focus on roman shade and
roll-up shade rear inner cord/lifting loop issues. While evaluating manufacturers' products for
roman shade back cord hazards and roll-up shade lift loop issues, CPSC staff caught numerous
other violations of the voluntary standard, including looped pull cords, no inner cord stops, no
tension devices provided with continuous loop products, and failure to attach a tension device
to a continuous loop cord. Almost all of these findings violated voluntary standard
requirements that had been in effect since the first standard was published in 1996. Many of
these non-complying products were on the market for years, and in one case, for two decades,
before they were detected and recalled. (Exhibit 2)
The CPSC does not have the resources to maintain this level of enforcement. This
example of how one short-term enforcement effort uncovered numerous standard violations
implies that many more undiscovered instances of non-compliance by Industry exist, and
that at least some portion of Industry cannot be relied upon to meet voluntary standards and
to manufacture compliant products.
DESPITE FEASIBLE SAFE ALTERNATIVES, VOLUNTARY STANDARDS
HAVE FAILED
Feasible Safe Alternatives
Safe alternatives exist and are feasible. For example:
Cordless technology
Cordless window covering designs that eliminate pull cords are available and
9
economically viable. Cordless window coverings, such as pleated shades, horizontal blinds,
cellular shades, wood blinds, and roman shades, have been made by a number of firms since
approximately 2000 (CPSC, 2000; Hunter Douglas, 2000; Levolor, 2001). Cordless products
of up to 78 inches wide and 84 inches long are available in all designs. Our research indicates
that the manufacturer's cost of such alternative cordless technology is only $2.00- $3.00 more
than the cost of an unsafe corded one-inch vinyl or aluminum blind. The manufacturer's cost
for such cordless operating systems on a two-inch faux wood blind is in the $7.00- $9.00
range. While the current design of cordless products may include size limitations, these sizes
encompass the overwhelming majority of all applications.
Furthermore, feasible and cost-effective alternative designs exist which likewise
address this issue. This issue can be solved by utilizing a wand-type device similar to those
used to tilt slats for light control.
Cord cover designs
In the 1990s, major window covering manufacturers developed and patented cord
cover devices to render the pull cords of window coverings inaccessible. (Springs, 1995a;
Springs, 1995b; Newell, 1996) However, major manufacturers never brought products with
this feature to market, and cord covers were essentially abandoned once the CPSC allowed
separated cord tassels to serve as a compliant design alternative.
More recently, one manufacturer has created and brought to market a cord cover design
aimed at eliminating accessible pull cords, at a price point that is affordable and cost effective
for both new-product and retrofit applications. (Safe-T-Shade, 201 0; Safe-T-Shade website)
This cord cover design renders pull cords inaccessible, while at the same time eliminating
concerns regarding the ability of cordless technology to meet very large applications, and
applications where furniture is placed in front of window coverings. Such cord cover designs
can accommodate any window size currently being served by cord-accessible products, and its
positioning in the same location as traditional pull cords accomplishes the same functionality
and accessibility as traditional corded products.
Voluntary standard efforts have failed
The economic reality is that the window covering industry is very competitive,
particularly in the area of stock products. If one manufacturer wants to adequately address
safety issues and render cords inaccessible at a slightly higher cost, it risks being undercut by
another manufacturer willing to sell less safe but cheaper products. Big box retailer contracts
can be lost over a matter of pennies, nickels, or dimes as major retailers seek the lowest
possible entry level price point in the window covering market. Absent a mandatory standard,
manufacturers seeking to introduce safer cordless and cord inaccessible products will suffer
from a competitive disadvantage against manufacturers willing to sell unsafe corded products.
Further, the large window covering manufacturers who dominate the WCMA and ANSI
standards writing process have a vested interest in maintaining low industry standards. Those
manufacturers have advanced custom product designs featuring cordless and cord inaccessible
10
coverings, on which they are able to maintain premium pricing- but only so long as there is an
absence of competition. Should standards mandate cordless or cord inaccessible product
designs, this feature will no longer be able to command a premium price.
Absent mandatory rulemaking that eliminates accessible window covering
cords, Industry has not and will not act alone. ANSilWCMA A100.1-2012 was
Industry's sixth attempt to address exposed operational cords, and it has again chosen
not to do so meaningfully, despite extreme U.S. pressure and an international mandate.
For all these reasons, it is evident that the only way to achieve safety is to invoke CPSC
rulemaking.
PETITION REQUEST
Despite the availability of feasible and cost effective design alternatives, Industry has
failed to adopt a voluntary standard which engages the first tiers of the safety design
hierarchy, i.e. to eliminate or guard against the hazard. It is only through design strategies
that the cord hazard will be adequately addressed and true safety achieved. The repeated
failure of Industry to adopt an effective voluntary standard over the last 28 years
demonstrates that CPSC rulemaking is required to eliminate the hazard posed by accessible
cords in window coverings.
As previously discussed, the latest voluntary standard is inadequate due to its allowance
of products with accessible cords, even when cordless and/or inaccessible cord options are
feasible. We believe a mandatory standard should eliminate all accessible cords:
The standard should prohibit the use of cords on window coverings when non-cord
design options are feasible. For example, cords are not necessary for the tilting operation
of horizontal blinds since wands can perform this function. Also, exterior pull cords on
window coverings are unnecessary for products that have cordless options - currently all
products measuring less than 78 inches wide and 84 inches long.
Ifthere are products for which accessible cords cannot be currently eliminated, due to
the large size of the product or other reasons, the standard should require that such cords
be made inaccessible through passive guarding devices, such as a cord cover.
We defer to the CPSC as to what is the best approach for this standard. For example,
one approach would be to ban all accessible cords, and to develop a mandatory standard to
define what constitutes an accessible cord. Since the CPSC staff has been working on this
issue in earnest since at least 1994, there is vast in-house expertise in this subject matter.
In closing, due to Industry's repeated failure to develop a standard that adequately
mitigates the risk of strangulation on corded window coverings, the Petitioners hereby
formally Petition for Rulemaking under the authority and process set forth in 16 CFR §
1051, et seq. and request the Commission to promulgate a mandatory standard that
prohibits any window covering cords where a feasible cordless alternative exists, and for
11
those instances where a feasible cordless alternative does not exist, requires that all cords
be made inaccessible through the use of passive guarding devices.
The Petitioners appreciate the Commission's consideration ofthis request. We
are available to discuss this petition at your convenience.
Respectfully submitted,
Petitioners:
Parents for Window Blind Safety
By: Linda Kaiser
President
PO Box 205
Barnhart, MO 63012
314-494-7890
[email protected]
Consumer Federation of America
By: Rachel Weintraub
Legislative Director and Senior Counsel
1620 Eye Street, NW, Suite 200
Washington, DC 20006
202-939-1012
[email protected]
Consumers Union
By: George P. Slover
Senior Policy Counsel
1101 17th Street NW, Suite 500
Washington, DC 20036
202-462-6262
[email protected]
Kids In Danger
By: Nancy Cowles
Executive Director
116 West Illinois St, Suite 4E
Chicago, IL 70754
312-595-0649
Nancy@KidslnDanger .org
12
Public Citizen
Congress Watch
By: Christine Hines
Consumer and Civil Justice Counsel
215 Pennsylvania Ave, SE
Washington, DC 20003
202-454-5135
[email protected]
U.S.PIRG
By: Nasima Hossain
Public Health Advocate
218 D Street SE, 1st Fl.
Washington, DC 20003
(202) 546-9707
[email protected]
Independent Safety Consulting
By: Carol Pollack-Nelson, Ph.D.
13713 Valley Drive
Rockville, MD 20850
301-340-2912
[email protected]
Safety Behavior Analysis, Inc.
By: Shelley Waters Deppa
18417 Shady View Lane
Brookeville, MD 20833
301-774-9682
[email protected]
Onder, Shelton, O'Leary & Peterson, LLC
By: James G. Onder
11 0 E. Lockwood, 2nd Floor
St. Louis, MO 63119
314-963-9000
onder@onderlaw .com
13
Interest of Petitioners
This petition is brought by nine organizations on behalf of all children and their families affected
by window covering cords:
Parents for Window Blind Safety (PFWBS) is a nonprofit organization that supports parents
whose children have been seriously injured or killed by dangerous cords, educates consumers
about the dangers of accessible window covering cords in homes, daycare facilities, and military
housing, helps create safer standards in the industry, encourages innovation of safer products in
the industry, and tests window covering products for safety.
Consumer Federation of America (CFA) is the nation's largest consumer advocacy
organization representing more than 260 state, local, and national consumer organizations that
was established in 1968 to advance the consumer interest through research, advocacy, and
education.
Consumers Union (CU) is the policy and advocacy division of Consumer Reports, an expert,
independent, nonprofit organization, whose mission is to work for a fair, safe, and just
marketplace for all consumers.
Kids In Danger (KID) is a nonprofit organization dedicated to protecting children by improving
children's product safety. KID was founded in 1998 by the parents of sixteen-month-old Danny
Keysar who died in his Chicago childcare home when a portable crib collapsed around his neck.
Public Citizen is a nonprofit consumer advocacy organization based in Washington, D.C.
founded more than 40 years ago and with more than 300,000 members and supporters nationwide.
U.S. PIRG, the Public Interest Research Group, is a non-profit, non-partisan public interest
advocacy organization that takes on powerful interests on behalf of its members, working to win
concrete results for our health and well-being.
Independent Safety Consulting (ISC), through its principal, Carol Pollack-Nelson, provides
14
human factors consulting specializing in consumer product safety, by evaluating product designs,
warnings and instructions in order to identify hazards and reduce risks to consumers. Ms.
Pollack-Nelson was a Human Factors Psychologist at the CPSC from 1988 through 1993.
Safety Behavior Analysis, Inc. (SBAI), through its principal, Shelley Waters Deppa, provides
human factors consulting on the safety of consumer products, with a specialty in children's
hazards, such as choking, suffocation, and strangulation. SBAI analyzes injury data, evaluates
product designs, and develops and tests safety labels for effectiveness. Ms. Deppa worked in the
CPSC's Human Factors Division from 1979 through 1992.
Onder, Shelton, O'Leary & Peterson, LLC pursues this petition on behalf of the over 50
families with whom they have worked whose children have strangled on window covering cords,
that window covering cord hazards might be eliminated.
15
Exhibits
Exhibit 1 -2013-04-26, SBAI, Incidents That Would Not Have Been Prevented By
ANSI/WCMA A100.1.
Exhibit 2-2013-4-26, SBAI, Standard Is Not Adequate Because Manufacturers Are Ignoring
The Voluntary Standard.
References
Listed in order of appearance in petition
Available upon request
CPSC (2007). 2007-08-01, CPSC Release #07-256 "Top Five Hidden Home
Hazards." CPSC (2013a). CPSC Website, CPSC Safety Alert, "Are Your Window
Coverings Safe?"
CPSC, HC, DG SANCO (2010). 2010-06-15, Letter from CPSC, Health Canada and
DG SANCO to WCMA, ANSI, CEN-CENELEC and CSA Standards regarding joining
together and requesting industry support for "a swift and comprehensive process that
concurrently eliminates the risk factors causing deaths and injuries from all types of
corded window covering products".
CPSC (20 11 a). 2011-06-01, Letter from CPSC Chair, Inez Tenenbaum to Ralph
Vasami, Executive Director ofWCMA reaffirming her call "for a more comprehensive
revised voluntary standard that eliminates-not just reduces-the strangulation risks
from window coverings."
CF A (20 11 ). 2011-09-0 1, Press Release of Consumer Federation of America,
Consumers Union, Independent Safety Consulting, and Parents for Window Blind
Safety, available on the web at:
http://www.consumerfed.org/pdfs/WindowCoveringsStandardPressRelease.pdf
CPSC (1985a). 1985-07-03, Memorandum of Telephone Conversation between Stan
Marrow and Peter Rush- determining Association's interest in issuing a joint
consumer safety alert.
CPSC (1985b). 1985-09-13, Agenda of Meeting between A WCMA and CPSC Staff
- Proposed Safety Alert recommending parents to "Cut off any excess cord, or cut it
to lengths that will not be able to be reached by children".
CPSC (1985c). 1985-12-00, CPSC Consumer Product Safety Alert "Parents Warned
16
about the Danger of Strangulation if Children Become Entangled in Window Blind
or Drapery Cords."
DWC (1988). 1988-01-00, Draperies and Window Coverings: Warning Tags from
A WCMA- Bottom rail labels and hang tags.
WCSC (1994). 1994-09-00, WCSC Voluntary Corrective Action Plan submitted to
CPSC.
CPSC (1994a). 1994-10-03, Letter from David Schmeltzer, CPSC Office of Compliance
to Peter Rush, WCSC re: Window Covering Corrective Action Plan.
FAA (1993). 1993-12-00 Evaluation and Testing of Three Cord Management Devices,
prepared for Levolor by Failure Analysis Associates, Inc.
CPSC (1994b). 1994-03-31 Memorandum from Renae Rauchschwalbe to The
Commission Re: Minutes ofMeeting between CPSC Staff and WCMA.
CPSC (1994c). 1994-04-05 Memorandum from Scott Heh, ESME to Renae
Rauchschwalbe Re: ESME Response to PSA No. 9124, Hunter Douglas, Inc.
CPSC (1994d). 1994-05-24 Memorandum from Celestine Trainor to Renae Rauchswalbe
re: PSA 9287; Springs Window Fashions- Two Cord blind Fix.
CPSC (1994e). 1994-06-02 Memorandum from Scott Heh, ESME to Renae
Rauschwalbe, CECA Re: PSA No. 9293, Spring Window Fashions, Blind Cords.
CPSC (1995). 1995-11-21, Letter from Marc Schoem, CPSC Division of Corrective
Actions to Peter Rush, WCMA re: Follow-up to WCMA meeting ofNovember 14, 1985.
CPSC (1999). 1999-09-03, Letter from Renae Rauchschwalbe, CPSC Office of
Compliance to Peter Rush, WCSC re: WCSC Strangulations Due to Cords that Run
Through Window Coverings.
WCSC (2000a). 2000-09-12, WCSC Voluntary Corrective Action Plan submitted to
CPSC.
WCSC (2011). 2011, Window Covering Safety Council Website- Basic Cord SafetyUrges parents to "Install only cordless window coverings in young children's bedrooms
and sleeping areas."
WCSC (2000b). 2000-11-01 WCSC Release: WCSC Alerts Consumers To New
Window-Blind Hazard; Free Repair Kit is Available.
NYT (20 11 ). 2011-09-01, NYTimes.com, "Consumer Advocates Withdraw from Talks
on Improving the Safety of Window Blinds."
17
CPSC (20 11 b). 2011-08-04, International Consumer Product Health and Safety
Organization Conference -CPSC Chair Inez Tenebaum in reference to the industry states
"It's time to 'eliminate' the strangulation risk on window blind cords."
RILA (2011). 2011-09-12, Letter from Jim Neill, RILA to Ralph Vasami, WCMA
urging industry to adopt standard that includes: eliminating any cord, including
operational cord that can form a hazardous loop and address continuous loop tie down
devices.
CPSC (2012). 2012-02-06, Letter from Rana Balci-Sinha, CPSC Division of Human
Factors to Ralph Vasami, WCMA comments on the ANSIIWCMA A1100.1-2010
American National Standard for Safety of Window Covering Products.
CPSC, 2013b). 2013-03-18 CPSC Memorandum from Colin Church, Voluntary
Standards Coordinator to The Commission re: Voluntary Standards Activities FY2012
Annual Report- Blind Cords- Revise ANSI/WCMA A 100.1 to reduce strangulation
hazards associated with window covering cords.
Comfortex (1994). 1994-04-03, Letter from John Schnebly, Comfortex to Ann Brown,
CPSC urging the "Commission to rethink its potential endorsement of the Hunter
Douglas Breakthrough Safety Tassel."
CPSC (2000), 11/1/00, CPSC Release #01-023, "CPSC, Window Covering Industry
Announce Recall to Repair Window Blinds- New Investigation of Children's Deaths
Leads t Redesigned Window Blinds."
Levolor (2001), 3/26, Cordless Technology Provides Safest Alternative in Window
Blinds and Shades, www.prnewsire.com/news-releases, 71825207.html.
Hunter Douglas (2000) http://www.hunterdouglasgroup.com/company/history.jsp
Springs (1995a). 1995-11-04 United States Patent: 5,465,775 Venetian Blind with Wand
Operator - Assigned to Springs Window Fashions Division, Inc.
Springs (1995b). 1995-12-05 United States Patent: 5,472,035 Window Blind with Wand
Operator - Assigned to Springs Window Fashions Division, Inc.
Newell (1996). 1996-05-07 United States Patent: 5,513687 Safety Device for Pull Cords
of Window Coverings- Assigned to Newell Operating Company.
Safe-T-Shade (2010). 2010-03-27 Press Release: New Lift System For Window Shades
Engineered to Protect Children's Lives.
Safe-T-Shade (website). www.fashionwand.com
18
Footnotes
I 1985: 8539000973, 8527004494, 850510WES4198, 8537017776,8506093927,8549005084, 8512080995
8501024422,8521023686,8512090059, G85A0131A, 8548102449, C4C5034A1
2
1986: 8606003626,8604009348,8636028540, X655212A1, 8612060372,8648060413, 900816HCN2237,
8602001593, 72S2234A1
3
1987: 8790630230-S, 870604023 7, 8740008599, 8704014317, 8751029702, 739064029, 8718041406
G87B0176A, 8712123753
4
1988: 8837000499, 890711HCC1348, 890808HCC3233, 8838002200, 890808HCC3234, X89B0329A,
890711HCC1347, 890829HCC3254
5
1989: 890526HCC1327, 891107HCC3351, 890060HCC1836, 890829HCC3258, 900531HCC3564,
890816HCC1384, 890828BEP0009, 900130HCC3418, 890926HBB3259, 900105HWE4005, 901115HCC2043,
891103HCC1544, 901219HCC0085, 891120HWE5013, 900119HCC1616
6
1990: 900524HCC2219, 900920HCC2015, 9020005539, 921119HCC1912, 900530HNE5188,
00724HWE5019, 900723HCC3611, 901218HCC1095, 901101HCC0033, 901218HCC2062, 901213HCC0074,
901227HEP9001
7
1991: 910123HCC0118, 910305HCC0153, 910213HCC1140, C94B0041A, 910503HCC0210,
920529HCC0188, 910521HEP2641, 971009CCC2057, 910712HCC2229, 910718HCC1333, 910807HCN1881,
910905CWE7078, 950224CCC2392, X9196730A, 910912HCN2234, 911211HCC0052, 911031HCC1464,
920722HCC2207, 920722HCC2208
8
1992: 92030HNE5088, 920901HCC3229, 930303HCC3140, 920721HCC1775, 920422HEP1281
930222HCC3127, 930322HCC3159, 920720HCC1774, 930127HCC3090, 9206113354,920811CWE5005,
920928HCN2681, 921028HCC3034, 930303HCC3141, 930126HCC3087,921119CWE5024, 930409HCC1096,
930201HCC1027, 930126HCC3086
9
1993: 930614HCC3232, 930310HCC1065, 9338001173, 9301015308, 930518HCC1131, 930915HCC3310,
930715CWE50 10, 940126HCC2056, 930920HCC 1775, 930923HCN2539, 960327CCC5075,940421 CCN1236,
G93C0218A, 9401 03CWE500 1
10
1994: 940302CWE5007, 940420CCC1437, 940415CCN1214, 940421CCN1237, 940603HNE5149,
950328CCC1521, 951208CCC1228, 941116HCC3016, 940623CBB2564, 951214CCC3246, P9714316A,
940802CBB3670, 940802CBB3669, 941101 CWE5006, 960805HCC5429, 951122CCC3190, 950330CCC3537
11
1995: 950301CCC1401, 950216CCC1367, 961205CCC5112, 950410CCC3574, 950407CEP9005,
950615CWE5009, 950710CCC3842, 960108CCC3273, 950626CCN2286, 950721CEP9014, 950906CCC1961,
950727CWE1400, 951011 CBB 1085, 970319CCC1 036, 951128CWE7315, 960305CCC7064, 9511 08HCN0229,
9601 08CBB2261
12
1996: 970814CCC2375, 960326CBB5070, 960304HCN0685, 960227CWE5006, 960403CCC5089,
960403CEP9003, C9650020A, 960611CCC5239, 960827CBB5576, 960520CNE5140, 960524CCC5190,
19
96061ICCC5238, 970218CCC5320, 960717CCC5351, 970619CCC3227, 961114CBB5049, 961023CCC5005,
9611 07CCC5040, 9611 07CCC5036, 961125CWE7249, 970319CCC I 026, 970708CCC3254
13
1997: 981020CCC3026, 970127CNE5071, 980115HCC3534, 97032ICWE4110, 9801 13CCC2220,
9720005138, 970916CWE4149, 970418CEP900 I, 98 I 001 CCC40 14, 970522CCC3168, 970709CCC3258,
970808CCC3288, 980508HCC2533, 971015CCC1584, 971 I I 9CCC1679, 971 I 19CWE5009, 980105CCNOI 16,
980 I 09CCC2 I 77, 980 I I 2CCNO I 31
14
1998: 980209CCC3581, 980218CCC0073, 980305CBB5364, H9840074A, 980522CCCI437,
980326CCC023 I, 9803 I OCBB6684, 980528CCC6842, 98070ICWE71 75, 980813CBB5779, 980821 CBB0662,
981222CCC2128, 001013CBB0041, 990818CCC0674
15
1999: 990325CCC0369, 990728HCC3423, 990 I 2 I CBB2205, 990520CNE5 I 72, 990618CWE6004,
00101 7CBB2033, 0101 I 7CCC0232
16
2000: 001 I 17CBB3055, 00225CBB2293, 000331CWE6005, 000714CNE5665, 010628CCC3361,
010323CCC3221, 10040144A, 000518CNE5554, 00083ICNE5737, 010614HCC2573, 001121CCC3068,
001108CCC0089, 001 102CNE5849, 001213CCC3106, 010111CCC3134, 030908CCC3405
17
2001: 010109CBB0204, 010125CNE6092, 1/30/01, H0130329A, 010205CCN0282, 010607CCC3331,
010614CBB2575, 010510CNE6334, 010615CNE6462, 010625CCN0689, 010713CCC1724, 011212CCC21 I 8,
010723CCC2641, 2/25/09 Sauk Rapids MN, 010815CNE6651, 01121 ICCC1174, 020301CCC1368,
020 122CEP9002, 030 122CCC 1285
18
2002: 020107CCN0223, 021016CCC3022, 020719CEP9009, 02061 1CEP9004, 020417CEP9003,
020610CCC1605, 020716HCC3266, 020604CNE7347, 020619CCN0542, 020807CCN0684, 020812CNE7432,
020905CCN0794, 020924CWE5017, 9120102 Wichita KS, 021 112CCN0097, 021 107CNE7560, 030123CCC2290,
030123CCC2289, 021218CCC3132, 021219CCN0213
19
2003: 030707CWE4337, 030515CEP9004, 03042ICCC2409, 030402CCCI421, 03031ICWE5004,
030515CEP9003, 030723CCC1740, 030418CCN0479, 030521CBB2460, 030519CWE6003, 030612CCN0613,
030708CCC3335, 031113CCC3048, 030828CNE8057, 030903CCN0864, 030902CCN0848, 040423CCC3268,
0337093050-S, 040106CCC1316
20
2004: 040319CNEI406, 040629CEP9007, 040505CCC2500, 070914CCC1818, 040729CCC3405,
040722CCC2648, 0425981140-S, 041 I 19CCC2143, 041117CCC2129, 050124CCC3175
21
2005: 050119CWE3007, 050303CCC1535, 060202CCC2315, 050407CCC3309, 050414CNE2280,
050426CCC3334, 7/14/05, 050804CCC1029, 7117105 Chillicothe OH, 050923CCC3504, 1012IOCCC1179,
Xl050632A, 051206CCC3182, 0527035661, 060830CCC1755
22
2006: 060124CCC1326, 060118CWE5081, 060308CBB1394, 060328CCC2466, 070213CCC3245,
060502CCC3480, 060602CCC 1567, 0608 I 1CCC3785, 060920CCC3892, 061207CCC1153, 070213CCC3243
23
2007: 070221CCC3260, 070719CCC2643, 070308CCC2346, 071219CCC3250, 07053ICCC2538,
070703CCC1583, 100106CCC2286, 070828CCC2757, 0742086600, 090811CCC3851, 071127HNE2987, 2007
(month and day unknown) Houston, TX
24
2008: 080122HNE3082, 080124CCC1351, 090811CCC3850, 0803IOCCCI480, 080423CCCI551,
080415CCC1535, 081112HWE7844, 080424CCC2597, 100106CCC3229, 080530CCC2699, 080625CCC3646,
611 I /08 Atlanta GA, 080702CCC 1707, 080812CNE367 5, 109C I 052A, 090204CCC 1402, 080729CCC3 726,
110421CCC3667, 081002CCC2008, 081 I06CWE7837, 080915HNE3763, 090108CWE7977, I 1/13/08 Shelton
20
WA, 081120CCC2142, 090115CCC1355, 090121CCC2276
25
2009: 090921CCC1073, 2/1/09 Flagstaff AZ, 2/9/09 Supply NC, 090227CCC3369, 111116CCC3139,
090602CCC3635, 090728CCC2797, 090407CCC3500, 4/?/09 Bennettsville, SC, 090827CCC3926,
090410CCC2531, 090414HWE8180, 090416CCC2545, 090528CCC3624, 090901CCC3939, 100324CWE2013,
090910CWE8430, 090710CCC3731,100111CCC3235, 6/15/09 Creve Coeur MO, 090901CCC1033,
090629CNE4548, 091008CBB1013, 109C1086A, 091009CCC2026, 090728CCC2792, 0949020967,
100324CWE2012, 090817CNE4677, 090903CBB2900, I0981284A, 090921CCC1076, 090915CCC3962,
091223CCC1197, 091102CNE4799, 091106CCC3071, H09B0125A, 100714HWE2255, 100105CCC3221,,
I09C1024A, 091210CCC3160, 091215CCC2238, 100106CCC2286, 100111CCC3232
26
2010: 100405CCC3517, 100125CWE1054, 100217CCC3328, 100219CCC2387, 120402CCC2594,
100304CCC1300, 100308CCC2444, 100322CNE0248, 4/6/10 Springfield OH, 100413CCC3564, 100427CCC2639,
100519CWE2035, 100708CWE2246, 100803CCC1015, 101018CCC2063, 101207CCC3281, 101103HWE2393,
100915CBB3131, 100920CBB1174, 101123CCC2136, 101104CCC1094, 110103CCC3322, 101214CCC1191,
11 0204CCC3423, 110 103CCC3319
27
2 011: 110601 CNEOOO 1, 11 0315CCC1402, 11 0404CCC2425, 11 0516CCC3728, 11 0607CCC3794,
111206CCC3198, 111018CCC2027, 111024CNE1400,
28
2012: 120501CCC1644, 120709CCC3743, 120727CCC2904, 120816CWE5001, 120918HWE3109, 9117112
Sioux Falls SD
21
Exhibit 1
Incidents That Would Not Have Been Prevented by ANSI/WCMA A100.1-2012
Analysis by Safety Behavior Analysis, Inc. (412611 3)
TOTAL NUMBER OF WINDOW COVERING INCIDENTS
293 Total number of window covering incidents between 1996 and 2012 (2010- 2012
information incomplete):
-=--.1J. Incidents where unknown/inadequate info to indicate whether in the outer cord
loop, inner cord loop, or wrap-around and therefore can't tell whether separate
cords/tassels would have made a difference.
= 250 Incidents with enough information to determine whether outer cord loop, inner
cord loop, or wrap-around was involved
KNOWN INCIDENTS BETWEEN 1996- 2012 (2010 to 2012 info incomplete)
THAT WOULD NOT HAVE BEEN PREVENTED BY CURRENT VOLUNTARY
STANDARD
55 (Table A) Incidents on manufacturer separated outer cords, including those with
breakaway tassels or breakaway cord joiners, which caused injury or death via
knotted/tangled loop, defective break away, or wrap-around.
A( 1) Incidents on pull cords with separate tassels = 51
A(2) Incidents on tilt cords with separate tassels = 4
29 (Table B) Incidents on looped outer cords where the manufacturer created loop
did not cause the incident, This includes following categories
B(l) incidents on looped outer cords where child not caught in manufacturer
created loop but was wrap-around = 16
B(2) incidents in looped outer cords where child not caught in manufacturer
created loop but caught in tangle/knot above tassel = 13
5
(Table C) Continuous loop incidents where a tension/tie-down device was present
but either not installed, had pulled out of wall or broken (number doesn't include
1 possible but unverified incident listed on sub-table)
6
(Table D) Other instances where caused by a hazardous cord allowed by the
standard - such as reverse inner cord incidents, caught in cord joiner loop on
multi-corded window coverings
1 (Table E) Incidents which occurred where manufacturer's failure to make
according the voluntary standard contributed to the cause of incident
= 102 Incidents would not have prevented by the voluntary standard.
More than 40% (1 02 of 250) of all incidents would not have prevented by the current
2012 voluntary standard.
Injury Data Table A (1996-2012 w/2010-2012 dataset incomplete)Known Outer Cord Incidents Involving Manufacturer Separated Cords
i.e. Separate Tassels, Breakaway Tassels, Breakaway Cord Joiners & Tilt Cords
(in knotted/tangled loop, defective break away, or wrap-around)
55 total incidents (32 fatal, 4 severe injuries, 19 other injuries)
A(1) Incidents occurring on pull cords with separate tassels, breakaway tassels or
breakaway cord joiners
Case#
Date
10/29/96
Age/
Sex
4 yrs/ F
970319CCC 1026
Injury
Rome, NY
970418CEP900 1
4/8/97
21 mos I M
Injury
Chicago, IL
981001CCC4014
4/17/97
14 mos I M
Fatal
El Cajon, CA
970808CCC3288
7/28/97
4 yrsl M
Injury
Kirkland (Bellevue), W A
990121CBB2205
1116/99
15 mos /M
Fatal
4 yrsl F
Fatal
15 mos I M
Injury
Roselle (Chicago) (Glendale
Heights), IL
010628CCC3361
3/20/00
or
0008006909
3/21/00
Douglas, WY
Denver, CO
000518CNE5554
4/16/00
Outcome
Columbia, TN
000831CNE5737
8126100
2yrsiM
Fatal
Ambrid_g_e _(Pittsburgh}, PA
001108CCC0089
10119100
2.5 yrsl M
Injury
Peabody, MA
010614CBB2575
4122101
1 yrl F
Fatal
Sealy (Austin), TX
01 0723CCC2641
7121101
4 yrs I M
Injury
Utica MI
Case#
Date
010815CNE6651
Newnan, GA
020301CCC1368
X0210720A
8/10/01
Age/
Sex
6 yrs/ F
Fatal
10/27/01
20 mos/M
Fatal
Old Bridge, NJ
020107CCN0223
1/5/02
3 yrs I M
Injury
Lincoln, NE
02061 occc 1605
4/8/02
8 mos IF
Fatal
Carriere (Picayune), MS
020812CNE7432
8/8/02
18 mos I M
Injury - Severe
Bridgewater, MA
020905CCN0794
913102
4 yrs I M
Fatal
Corinth, TX
030707CWE4337
1/7103
17 mos /M
Fatal
Phoenix, AZ
030418CCN0479
4116103
14 mos IM
Fatal
Sheboygan, WI
030708CCC3335
6116103
4 yrsiM
Fatal
San Francisco, CA
030828CNE8057
8126103
16 mos IM
Fatal
Charlotte, NC
030902CCN0848
08131103
4 yrs/ M
Fatal
9130103
17 mos I M
Fatal
Middletown (Cincinnati)
lrButler County), OH
040423CCC3268
0344194240-S
0341024944
Outcome
(DC 1011/03)
Eugene (Portland), OR
050303CCC1535
214/05
3.5 yrs IF
Fatal
Naples (Golden Gate), FL
050426CCC3334
215105
4121105
3 yrsiM
Injury
Pacifica, CA
Case#
Date
Xl050632A
Parent email to PWBS
11118/05
El Cajon, CA
0603 28CCC2466
Gulfport, MS
060502CCC3480
3/10/06
(IDI- typo, says
3110104)
4/11/06
Age/
Sex
4 yrs I M
Injury
2 yrs /M
Injury
15 mos IF
Fatal
Injury
Outcome
Elk Grove, CA
I 00 I 06CCC2286
8/8/07
lfJ4 mos)
2 yrs I M
Minonk, IL
070828CCC2757
8/20/07
14 mos IF
Fatal
Helena, AL
080122HNE3082
1/17/08
3 yrs/ M
Fatal
Crystal Lake, IL
090204CCC 1402
7/5/08
4 yrs/ M
Fatal
Essex, MD (Baltimore),
MD)
090602CCC3635
3/1/09
2.5 yrs I M
Injury
09041 OCCC2531
4/8/09
5yrs/F
Injury
Ft. Benning, GA
090528CCC3624
4/29/09
3 yrs/M
Fatal
Garland, TX
090817CNE4677
8/9/09
2 yrs I M
Fatal
1/30/10 or
1/31/10
2 yrs IF
Injury
2114/10
3yrs/M
Injury
Phoenix, AZ
Gaithersburg, MD
Washington, DC
100217CCC3328
Colorado Springs, CO
I 00219CCC23 87
X1020251A
Saltillo, MS
(DC- 8/11/09)
Case#
Date
100519CWE2035
CPSC Release #11-036,
11/10/2010
5/16/10
Age/
Sex
22 mos /M
Fatal
Outcome
(5/25/1 0)
Cedar Falls (Iowa City),
lA
I 00708CWE2246
6/9110
3 yrs IF
Fatal
Great Falls, MT
I 009I5CBB313I
XI090325A
9/10/IO
5 yrs I M
Injury - Severe
I 0/30/I 0
2I mos IF
Fatal
League City (Dickinson),
TX
IOII23CCC2136
(DC- I8 mos I F)
Medway (New Carlisle)
(Dayton), OH
IOII04CCCI094
II/2/1 0
22 mos IF
Injury - Severe
Burlington (Burlington
TWP), NJ
IIOI03CCC3322
II/I0/10
4yrs/M
Injury
Albany, OR
IIOI03CCC33I9
I2/3IIl 0
I2 mos IF
Injury
3/3/II
2-~
Spring, TX
II 060 I CNEOOO I
yrs IF
Injury - Severe
Richlands (Camp Lejuene),
NC
II03I5CCCI402
3/5/II
11 mos IF
Fatal
Ellicott City (Columbia)
Baltimore City), MD
II 0404CCC2425
3/I8/II
20 mos /M
Fatal
Delavan (Geneva), WI
III206CCC3I98
8/27/II
2yrs/M
Fatal
Seattle, WA
(DC- 3/11/II)
Case#
Date
Ill 0 18CCC2027
I 0/4/11
Age/
Sex
3 yrs /M
Outcome
Fatal
9/3/12
5yrs/M
Fatal
Bonaire, GA
120918HWE31 09
Kenosha, WI
A(2) Incidents occurring on the separate tilt cords (not pull cords) of horizontal blinds
Case#
Date
080915HNE3763
Miramar (Pembroke Pines),
FL)
090728CCC2797
Rockford, IL
I 00308CCC2444
Elk River, MN
120727CCC2904
Clarksville, TN
Outcome
9/13/08
Age/
Sex
3yrs/M
Fatal
315/09
2 yrs I M
Injury
3/5/10
4 yrs I M
Injury
7/10/12
3 yrs/F
Fatal
Injury Data Table B (1996 -2012 w/2010 to 2012 incomplete): Window Coverin2sIncidents on window coverin2s with looped pull cords but involvin2 wrap-around or knot
in loop cord
29 incidents total
B(1) Wrap-Around Incidents includes one that may be a combination cord joiner/wrap
around (16 total, 8 fatal, 1 severe injury, 6 other injuries, 1 no injury)
Case#
Date
960304HCN0685
2/6/96 or
2/5/96 or
217/96
Veedersburg (Crawfordsville),
IN
9611 07CCC5040
Age/
Sex
4.5 yrs/ F
or
3yrs/F
Fatal
Outcome
2 yrs/ F
Fatal
Hunt Valley (Baltimore), MD
980305CBB5364
9/16/96
or
9/1/96
2/4/98
2.75 yrs 1M
Fatal
Eddyville, lA
H0130329A
2/1/01
3yrs/M
Injury
Ft. Leavenworth, KS
010625CCN0689
6/7/01
4yrs/M
!No injury
Michigan City, IN
020417CEP9003
3/28/02
22 mos/M
Injury
Everett, WA
030515CEP9003
3/13/03
3 yrs/M
Injury
Lake Stevens, WA
030723CCC1740
3/29/03
10 mos IF
Fatal
Philadelphia, PA
050407CCC3309
3/17/05
4 yrs/ M
Injury
I 0/11/05
13 mos /M
InjurySevere
Broomfield, CO
101210CCC1179
XIOC0115A
La Plata, MD
Case#
Date
051206CCC3182
12/1/05
Age/
Sex
18 mos IF
Fatal
Bothell (King County), WA
080530CCC2699
5/17/08
12 mos
14 mos/M
Fatal
Loganville (Snellville), GA
080625CCC3646
6/9/08
12 mol M
Fatal
3/29/09
lr15 moM)
8 mos /M
Fatal
11/4/09
3Y2 yrs I M
Injury
4/13112
2yrs/M
Injury
Mesa, AZ
090407CCC3500
Outcome
Oklahoma City, OK
X09B0059A
1114/09 email to PWBS
Lynden, WA
120501CCC1644
Jacksonville, NC (Camp
LeJeune)
B(2) Incidents involving a knotted or /tangled cord above manufacturer created
loop -where child caught in loop above knots
(13 incidents - 10 fatal, 1 severed injury, 2 other injuries)
Case#
Date
9801 09CCC2177
Mendota Heights (St. Paul), MN
980326CCC0231
11127/97
or
12/01/96 (DC)
2/28/98
20 mos IF
Fatal
Miami, FL
980528CCC6842
05/14/98
3 yrs/ M
Fatal
Tacoma, WA
981222CCC2128
9/1198
5 yrs/ F
Fatal
Roseville (Columbus), OH
0010 13CBB0041
10/26/98
Fatal
Antrim (Peterborough)
lrManchester), NH
001102CNE5849
17 mos IF
or
16 mos IF
1111100
13 mos I M
Fatal
01051 OCNE6334
5/8/01
or
14 mos I M
3yrs/M
Fatal
Fayetteville, NC
01 0723CCC2641
I0170330A
7/21101
4yrs/M
Injury
Utica, MI
020604CNE734 7
5/28/02
17 mos I M
(or 19 mos/ M)
Fatal
Richmond, VA
030402CCC1421
2/27/03
Union City (Union), TN
040722CCC2648
7/6/04
3 yrs/M
Fatal
(2 days short of 3rct
b'day)
Fatal
2.5 yrs I M
Ennis (Waxahachie), TX
041119CCC2143
9/30/04
2yrs/M
Willingboro, NJ
Wildwood (Chicago), IL
Age/
Sex
20 mos IF
Outcome
Fatal
Injury
Case#
Date
Sheriffs Report, Photo & parents
depositions
11113/08
Shelton WA
Age/
Sex
3yrs/F
Outcome
Injury- severe
Injury Data Table C (1996- 2012 w/20120- 2012 data set incomplete)- Window Coverin~:s
Continuous loop incidents where there is a tension device present that
was not installed/pulled out of wall or broken
(5 confirmed incidents followed by sub-table of listed but
not counted I possible unverified incident - all 6 incidents are fatal)
Case#
Date
02I 0 I6CCC3022
I/7/02
Age/
Sex
3 yrs/ F
Outcome
Fatal
Wheatland, WY
050804CCC I 029
7/5/05
7/I5/05
Portsmouth (Yorktown) (Langley AFB), 7/17/05
VA
0608IICCC3785
7/30/06
3 yrs I M Fatal
18 mos I
M
Fatal
San Bernadino, CA
(DC - 8/7/06)
09092I CCC I 07 6
9/II/09
lq7 mos)
3 yrs I M Fatal
Norfolk, VA
II05I6CCC3728
4/8/li
5 yrs/M
Case#
Date
060830CCC1755
12/31105
Agel
Outcome
Sex
2yrs/M Fatal
Fatal
Mill Creek, WA
Possible but unverified incidents:
Virginia Beach (Norfolk). VA
Injury Data TableD (1996 -2012 w/2010 to 2012 data set incomplete): Window Coverin~:s
Other incidents caused by a cord that met the standard - such as reverse inner cord
incidents, cau~ht in cord joiner loop on multi-corded window coverin~s
6 incidents total (5 fatal, 1 injury)
Agel
Sex
1 yr/ F
Fatal
3/17/00
or
3118/00
2 yrs/ M
Fatal
113/06
2yrs/M
(3 yrs)
Injury
4/8/08
3yrs/M
Fatal
12/29/08
2yrs/M
Fatal
3yrs/M
Fatal
Case#
Date
990325CCC0369
113/99
Whiteville, NC
000714CNE5665
Irvington, NY
Mt. Pleasant, NY
060 124CCC 1326
Orlando, FL
081112HWE7844
Wahiawa, HI
Schofield Barrack, U.S. Army
Military housing
090121CCC2276
Outcome
(12/30/08)
Sartell,MN
090921 CCC 1076
!Norfolk, VA
9/11/09
Injury Data Table E (1996- 2012 w/2010 to 2012 dataset incomplete): Window Coverin&sIncidents caused or partially caused due to failure of manufacturer to comply with the
voluntary standard
7 incidents (4 fatal, 3 non-fatal)
Case#
060602CCC 1567
CPSC Release# 09-329
Date
Agel
Outcome
51I9106
Sex
4yrsiF
Fatal
6126108
2 yrs IF
Injury
2 yrs/M
No Injury
Pensacola, FL
080702CCC I707
CPSC Release #09-05I
Bristol, CT
(RI- N
I 012II08)
09092I CCC I 073
I/1109
CPSC Release # 09-325 (8126109)
Philadelohia, PA
09090ICCC3939
CPSC Release #I0-307
511109
5 yrs IM
Injury
Tacoma, WA
0907I OCCC3 73I
police reports, photos, ME report
5121109
2 yrs 5 mosl F
Fatal
Mesa, AZ
090629CNE4548
CPSC release I2-273
6126109
2yrsiF
Fatal
Commerce Township, MI
NIOI0309A; XIOI0430A
I008003099
11211I 0
3 yrs I M
Fatal
Firestone CO
Exhibit 2
Standard is Not Adequate Because Manufacturers Are Ienorine The Voluntary Standard
Compiled by Safety Behavior Analysis, Inc. (4/26113)
There are numerous recalls (16) involving blinds that were not manufactured in compliance with the voluntary standard. Most
of these non-compliances (13 of 16) appear to have been found as a by-product ofCPSC's 2008-2010 focus on roman shade &
roll-up shade inner cord/lifting loop issues. While checking on manufacturers products for roman shade back cord hazards,
and roll-up shade lifting loop issues; CPSC caught other violations of the voluntary standard including looped pull cords, no
inner cord stops, no tension devices provided with continuous loop products and/or failure to attach a tension device to a
continuous loop cord. Almost all of these violations were for standard requirements that were passed with the first voluntary
standard in 1996. Many of these violations went on for years and in one case 2 decades before they were caught and recalled.
CPSC
Release/
Recall#
Recall
Date:
Violation of Voluntary Standard
Yearvol
standard
req.
passed
Dates
manufactured
and/or sold
Length of
time
made/sold in
violation of
the Standard
#07-262
8/3/2007
CPSC and Springs Window Fashions announce recall of
Basic Blinds ® Window Blinds sold exclusively at Lowes
which "have a [!Ull cord that is looQed, gosing a
strangulation hazard to young children. CPSC File No.
RP070430, p. 75 et seq.
1996
Manufactured
November 2006
to July 2007.
8 months
#09-051
11120/2008
"Near Strangulation of Child Prompts Recall to
Repair Window Blinds by Green Mountain
Vista"Roller Shades have a continuous looped bead
chain that was either sold without a tension device or
tension device not attached to the continuous looped
cord.
1996
Sold
nationwide
from June 2005
through
September
2008
over 3 years
- - -
I
CPSC
Release/
Recall#
Recall
Date:
Violation of Voluntary Standard
Yearvol
standard
req.
passed
Dates
manufactured
and/or sold
Length of
time
made/sold in
violation of
the Standard
#09-090
1113/2009
Risk of Strangulation Prompts Recall of Window Blinds
Sold at Cost Plus and World Market Stores
nationwide from February 2006 through August 2008.
Roman Shades and Roll-up blinds have a looped pull
cord
1996
sold
nationwide
from February
2006 through
August 2008.
2
#09-329
8/26/2009
"Strangulation Death of a Child Prompts Recall To Repair
Window Blinds By Vertical Land" Hazard: Horizontal
Blinds: The blinds do not have inner cord stoQ devices to
prevent the accessible inner cords from being pulled out.
2002
sold in Panama
City and
Pensacola, Fla.
from January
1992 through
December 2006
4 years
#09-325
8/26/2009
"Near Strangulation Prompts Recall of Roman Blinds; Sold
Exclusively at IKEA'' MELINA Roman Blinds have a
continuous looned null cord that did not have the tension
device attached or was sold without a tension device.
1996
sold nationwide
from August
2006 through
June 2008.
1 yr, 10 mos.
#09-328
8/26/2009
"Risk of Strangulation Prompts Recall to Repair Roller
Shades by Lutron Shading Solutions Roller shade
annarently sold without either without a tension device or
without a tension device attached to the continuous looned
bead chain.
1996
Sold January
2000 through
April2009
9 yrs, 3 mos
~years
I
CPSC
Release/
Recall#
Recall
Date:
Violation of Voluntary Standard
Yearvol
standard
req.
passed
Dates
manufactured
and/or sold
Length of
time
made/sold in
violation of
the Standard
#10-074
12115/2009
Risk of Strangulation Prompts Recall ofRoman Shades by
Draper Inc. Roman shade with continuous looQ clutch
OQeration system. In addition to exQosed inner cords, there
was either no tie-down Qrovide and/or the tie-down was
not attached to the shade.
1996
Sold nationwide
form March
2000 through
September 2009.
9 yrs, 6 mos.
"#1 0-071
12/15/2009
"Near Strangulation Prompts Recall to Repair Roman and
Roller Shades Sold at Pottery Barn, Pottery Barn Kids, and
PB Teens" Roller shade without tension device attached.
1996
sold January
2003 through
October 2009.
6 yrs, 10 mos.
#10-070
12/15/2009
"Risk of Strangulation Prompts Recall to Repair
Matchstick Roll-up Shades by International Merchandise;
Sold Exclusively at Big Lots" Looped pull cords
1996
from January
2009 through
June 2009.
6 mos.
'
I
#10-711
#10-149
---
-
- -
12/17/2009
3/2/2010
- - - - - -
"Risk of Strangulation Prompts Recall to Repair Faux
wood blinds by American Vintage Group." Hazard:
Strangulation can occur when a child places his/her neck
between the cords of the pull cord above the breakaway
device and the device fails to breakaway.
1996
"Risk of Strangulation Prompts Recall to Repair Roman
Shades by Lutron Electronics" Sold without tension device
attached to continuous looQed cord.
1996
Sold in Texas
from April 2009
through
September 2009.
6mos
Sold nationwide
from January
2000 through
August 2009.
9 yrs, 8 mos
-
I
CPSC
Release/
Recall#
Recall
Date:
Violation of Voluntary Standard
Yearvol
standard
req.
passed
Dates
manufactured
and/or sold
Length of
time
made/sold in
violation of
the Standard
#10-261
6/10/2010
"IKEA Recalls Roller Blinds, all Roman Blinds and all
Roll-up Blinds Due to Risk of Strangulation" This recall
involves roller blinds that do not have a tension device
attached to the bead chain, all Roman blinds and all roll-up
blinds.
1996
Sold nationwide
from January
1998 through
June 2009.
11 yrs, 6 mos
#10-307
7/22/2010
"Near Strangulation Prompts Recall of Roman and Roller
Shades by Smith+Noble" This recall involves all roller
shades that do not have a tension device attached to the
continuous loop cord and all custom, made-to-order
Roman shades.
1996
Sold nationwide
from 1998
through April
2010.
12 yrs
#11-306
11/10/2010
"Strangulation Death of a Child Prompts Recall of Roman
Shade, Roll-up Blinds, and Roller Blinds by Hanover
Direct Domestications" This recall involves all styles of
Roman shades with inner cords, all styles of roll-up blinds,
and roller blinds that do not have a tension device.
1996
Sold from
January 1996through October
2009.
13 yrs, 10 mos
#12-273
9/6/2012
"Death of Child Prompts Recall of Window Blinds by
Blind Xpress Two-year-old strangles in cord" This recall
involves all Blind Xpress custom-made vertical blinds that
do not have a cord-tensioning device that attaches to the
wall or floor, as well as all horizontal blinds that do not
have inner cord stop devices.
1996
(attached
cord tension
device)
2002 (inner
cord stops)
Sold in
Michigan, Ohio
and Indiana
from January
1995 through
December 2011.
Vertical blinds
22 yrs
/
---
-
-
--------
-·
---------------
- - - - -
horizontal
blinds
9 yrs
- -
i
CPSC
Release/
Recall#
Recall
Date:
Violation of Voluntary Standard
Yearvol
standard
req.
passed
Dates
manufactured
and/or sold
Length of
time
made/sold in
violation of
the Standard
#13-707
1112112012
Hunter Douglas Recalls to Repair Custom Cellular and
Pleated Window Coverings Due to Strangulation Hazard.
No incident. Some of the cords inside the
breakawa:Y cord stoQ were tied in a single knot
which can 12revent the cord stoQ from functioning
as designed to break awa:Y. A child can become
entangled in a cord loop and strangle. Standard
cordlock top-down/bottom-up Duette and
Applause honeycomb shades; standard cordlock
top-down/bottom-up Hunter Douglas pleated
shades; Hunter Douglas Brilliance Privacy View
pleated shades and standard cordlock Duette and
Applause Duolite shades
1996
Sold nationwide
from January
2011 through
August 2012.
1 yr, 8 mos.
-
- -
-
----·----·-
-~--