Hz Wireless Radio Switches and Receivers

Transcription

Hz Wireless Radio Switches and Receivers
Hz Wireless Radio
Switches and Receivers
Items
Reference
Description
Single Channel Surface Wall Mount
2005713
-Available in white
-Indoor rated
Slim Single Channel Hand Held
2006138
2006139
2006140
2006141
2006142
White
Silver
Plum
Green
Orange
Slim Multi Channel Hand Held
2006143
2006144
2006145
2006146
2006147
White
Silver
Plum
Green
Orange
1810603
White
Recessed Designer Single Channel
-5 independent channels that can be programmed
to operate one or more motors.
-Indoor rated
1810604
Ivory
1810605
White
1810606
Ivory
Recessed Designer Multi Channel
-5 independent channels that can be programmed
to operate one or more motors.
-Indoor rated
Two Channel Key Chain Style Transmitter
2005326
-Available in black
-Sequence function
Four Channel Key Chain Style Transmitter
2005914
-Available in black
-Sequence function
43
Hz Wireless Radio
Switches and Receivers
Items
Reference
Description
Hz Radio Timer
2004960
-Compatible with all Hz radio operators. This timer can operate
multiple operators automatically at a set time.
-Indoor use only.
Hz Radio Key Pad
2006029
-Compatible with all Hz radio operators. This key can operate two
independent Hz radio operators.
-IP 54 Outdoor weather rated.
Hz Radio Dry Contact Transmitter
2005714
-This transmitter is designed to link Hz operators into most
home automation systems.
Hz Radio Receiver Motor Controller
1810602
-This radio receiver can be used with the SIMU standard AC motor
series T3.5, T5, T5DMI,T6, T6DMI, T8 and T8 override. This
control is compatible with all the transmitter switches shown above.
No job is too large or small for the Hz wireless technology which is the latest radio innovation from SIMU. It combines the
function of wireless switching with the added benefit of group control directly into the operator. Everything from individual
switching and sub grouping to a master control can be accomplished without the use of external controls. For more details
on this product please refer to the Hz control manual which features detailed information on wiring and program scenarios.
Note: This radio control system is not compatible with the RC200 sequence controlled radio.
44
Sequence Controlled
Radio
Radio Receiver and Transmitter Controls
This radio remote control is everything you need to operate your
SIMU operator. It's new designer look is stylish, compact and water
resistant. Built-in reliable features include sequence controlled
switching, remote location switching ability, run timer with automatic
shut-off and dry contact safety control hook-up. The designer remote
complies with Part 15 of the FCC Rules and can transmit over 300
feet.
Reference
Description
2005642
2005643
2005644
Transmitter-Two Channel
Transmitter-Four Channel
Transmitter-Twelve Channel
2005632
2005634
Receiver (120V-60Hz) surface wall mount
Receiver (Dry contact hook-up)
Note: This radio control system is not compatible with the Hz wireless control products.
Wiring for one motor
and one RC200 receiver
RC200 Receiver
PW
1 2
LD
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
CODE
MEMORY
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Fuse
4.0A
2
Terminal capacity: #14 AWG to #10 AWG
3
4
6
5
7
1
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
12
8
9
13
10 11
45
WHITE
BLACK
RED
GREEN
Antenna
JUMPER
1
- Ground (Green)
2
- Ground (Green)
POWER IN 120VAC
3
- Neutral
GROUND
4
- Hot 120VAC
NEUTRAL
5
- Direction 1 ( Black )
HOT
6
- Direction 2 (Red)
7
- Common (White)
*8 & 9 N. C. Reversing Sensor
10 & 11 Remote Override Switch (SPBS)
12 - Coax Antenna Connection ( not supplied )
13 - Standard Antenna ( supplied with unit )
NOTE: - If you are not using a safety device a jumper wire must be connected
to terminals 8 & 9.
- Do not cut antenna wire supplied with this unit.
- See complete instructions supplied with unit on transmitter programming.
M
N.O. SINGLE POLE
SINGLE THROW SWITCH
(REF#SPBS)
Operator
Electronic Control Systems
Automatic Environmental Controls
The Halcomaster 2200 is a control system for all types of window
treatments. Whether you are controlling retractable awnings,
rolling shutters or sun shades, the Halcomaster 2200 enables a
window treatment to provide shading from the sun and protection
from the wind automatically and conveniently. A digital display
read out allows you to monitor the sensors sun intensity and wind
speed levels. These settings can be adjusted easily from the control
unit.
SET
halcomaster
R
2200
Reference
Unit Function
2279073
2279193
2279194
Sun and Wind Control (white - surface mount)
Sun and Wind Control (ivory - 3 gang recessed mount)
Sun and Wind Control (white - 3 gang recessed mount)
2279055
2279010
2279139
2279058
2279054
Replacement / Additional Sun Sensor
Replacement / Additional Rain Sensor
Replacement / Additional Temperature Sensor
Replacement / Additional Wind Sensor
Replacement / Additional Sensor Bracket
The Halcomaster 2200USPRO allows for additional sensors
to be attached. It also allows for additional switches to be
remotely located.
Wiring for one motor
and one 2200PRO
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
Green (Ground)
Neutral
Hot (120V-60Hz)
2200-LO
SUN SENSOR
+
-
R
M
46
White
Green
Jumper
Black
Red
2200-RM
RAIN SENSOR
OPTIONAL
2200-WM
WIND SENSOR
Operator
Electronic Control Systems
Automatic Environmental Controls
WINDY
120V - 60Hz
The WINDY is designed to retract a motorized awning or sun shade
during windy conditions, whether your home or away. The WINDY
can also be used to close other window treatments such as rolling
shutters during those same windy conditions. The wind sensor is
adjustable and the automatic wind protection function is designed
to override the manual switch during high wind gusts. Other features
of the WINDY include the use of standard switches. Choose from
designer switches, toggle switches or rocker switches.
Reference
Unit Function
2005721
2009089
Wind Control for Awnings and Shades
Wind Control for Rolling Shutters
*
WARNING
THE “SWITCH COM” IS AN INTERNALLY PROVIDED
HOT (115VAC) POWER AND IS ONLY CONNECTED
TO COMMON TERMINAL OF THE SWITCH. DO NOT
CONNECT TO ANY EXTERNAL VOLTAGE SOURCE
(LINE POWER: HOT OR NEUTRAL) AS THIS WILL
CAUSE SEVERE DAMAGE TO THE CONTROL.
Wiring for one motor
and one Windy
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Wind
Meter
Terminal capacity: #14 AWG to #10 AWG
Wind
Speed
Adjustment
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
Motor
Switch
120V
*
N
Com
N L
Black
White
Red
* NOTE:
Turn the wind speed adjustment
down to minimum. Spin the wind
sensor and confirm the windy
activates in the correct direction.
If the windy activates the motor
in the wrong direction at a wind
signal, reverse the red and black
motor leads. Remember to turn
the wind speed adjustment back
up after testing.
Individual
Switch
M
Neutral
Green (Ground)
47
Hot (120V-60Hz)
Operator
Electronic Control Systems
Group Control Relays
Sub Group Switch
Master Switch
Individual Switch
Individual Switch
Individual Switch
Individua
all Switch
Individual Swiittch
GI.2
RI.3
Individual Switch
Individual Switch
RI.2
Relay group controls can be linked together to control
any amount of operators. SIMU can custom design a
group control system that will give you complete control
of your SIMU operators.
Reference
Unit Function
2282074
2282075
2282028
2282018
Two Motor Relay Group Control (master, individual) (RI.2)
Three Motor Relay Group Control (master, individual) (RI.3)
Two Motor Relay Group Control (master, sub group, individual) (GI.2)
Two Motor Relay Group Control (24-Volt switching) (RG.2)
2005718
2005719
2005717
Two Motor Relay Group Control (master, individual) Metal Box (RI.2M)
Three Motor Relay Group Control (master, individual) Metal Box (RI.3M)
Two Motor Relay Group Control (24-Volt switching) Metal Box (RG.2M)
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
Ground (Green)
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Hot Power L1 (Black)
Common N (White)
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
M
Motor
P
Power to Ind. Switch
Motor Direction (Red/Black)
Note: Connections are only at terminals
48
Operator
Electronic Control Systems
Wiring Relays
RI.2
N
N
N
N
CENTRAL
115V - 60Hz
N
N
L
L
POWER IN 115VAC
GROUND
Individual Switch
Individual Switch
Master Switch
RI2
5AMP MAX
* Two Motors
* One Momentary Master Switch
* Two Momentary Individual Control Switches
N
INDIVIDUAL
SWITCH
INDIVIDUAL
SWITCH
M
M
N N
N
CENTRAL
Individual Switch
Individual Switch
Individual Switch
N
115V - 60Hz
P
N
N
L
L
POWER IN 115VAC
GROUND
RI3
Master Switch
RI.3
P
5AMP MAX
* Three Motors
* One Momentary Master Switch
* Three Momentary Individual Control Switches
49
P
P
P
INDIVIDUAL
SWITCH
INDIVIDUAL
SWITCH
INDIVIDUAL
SWITCH
M
M
M
Operator
Electronic Control Systems
Wiring Relays
Mp
GI2
115V - 60Hz
Individual Switch
Individual Switch
Master Switch
GI.2
P
120V
P
P
M
M
115v Mp Mp
* Two Motors
* One Momentary Master Switch
* One Momentary Sub Group Switch
* Two Momentary Individual Control Switches
NEUTRAL
HOT
GROUND
M2
M1
RG.2
L L NNN
120VAC
POWER
115V - 60Hz
N
MOTOR1 MOTOR2
24VDC
0.1AMPS PER
RG2 IN GROUP
Individual Switch
Individual Switch
Master Switch
FUSE
5AT
RG-2
MOTOR 1
SWITCH
P
Individual switches
can be linked to
form a subgroup
* Two Motors
* Low-Voltage Momentary Master Switch
* Two Low-Voltage Momentary Individual Control Switches
Master Control
(AV or switch)
50
MASTER SWITCH
BUS LINE
(CENTRAL)
MOTOR 2
SWITCH
P
Individual switches
can be linked to
form a subgroup
Operator
Electronic Control Systems
Low Voltage
Battery Back-up System
Never be without POWER!
Power
On Line
STOP
Power
Off Line
Low
Battery
The BBU is designed to provide you with constant power to any SIMU
DC operator. The BBU operates from a battery that is charging while
standard AC current is available. Three LED lights on the front of the
unit keep you informed on your current power conditions. The unit also
has additional dry contact connections for external switching devices
such as home automation systems.
Reference
Wiring for one DC motor
and one BBS Unit
Description
2005715
2005716
Battery back up system with warning lights (white)
Battery back up system with warning lights (ivory)
2005586
Battery Replacement 12v 1.2 amp hour
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
CONNECT TO ALL
BBU’S IN A GROUP
L
external switches
control only this BBU
JP1
TECHNICAL DATA:
Input Voltage
Input Current
Motor Output Voltage
Motor Output Current
Battery Output
Standby Battery Current
Shut Down Battery Current
Size
External Switching
Bus Line
120 VAC 50/60Hz
50 mA
12 Volts Nominal
5 Amps Max. Polyfused
Voltage/Current Regulated Charging for
12 Volt 1.2 Ah Sealed Lead Acid Battery,
6.5 mA
.9mA
3.5“ X 2.5” (Fits in deep 2 gang plastic box supplied)
N.O., Momentary Dry Contacts Rated for 12 Volts
12 Volts DC
Jumpers on
Jumpers off
external switches control
all BBUs connected by
bus line
MASTER/LOCAL
SWITCH JUMPER
+
RED
+
_
MOTOR
BLACK
-
BATTERY
12VOLT 1.2 Ah
REF#2005586
51
N
BUS LINE
EXTERNAL SWITCH MASTER/LOCAL
MASTER
LOCAL
JP1
UP
DOWN
STOP
COMMON
LINE POWER 120VAC
(G) GROUND
(L) LINE
(N) NEUTRAL
JP1
U
D
S
+12
U D S +12 U D S G
SWITCH
BUS
EXTERNAL SWITCH
G
REF# BBU
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
Motor Wire 16 gage min.
20 foot max length
BROWN
BLUE
Operator
Electronic Controls
Security Key Switches
Items
Reference
Description
Single Pole, Double Throw, Maintained Contact
2001547
-Surface mount
* 3 keys included.
2001549
-Recessed mount
Single Pole, Double Throw, Momentary Contact
2001548
-Surface mount
* 3 keys included.
2001550
-Recessed mount
Single Pole, Single Throw, Momentary Contact
2001551
-Surface mount
* 3 keys included.
2001552
-Recessed mount
Commercial Grade
Single Pole, Double Throw, Momentary Contact
2005616
-Surface mount
* 3 keys included.
Commercial Grade
Single Pole, Double Throw, Momentary Contact
2005614
-Recessed mount
* 3 keys included.
2005752
Standard Key Switch Extra Keys
2005613
Commercial Grade Extra Keys
52
Operator
Electronic Controls
Security Key Switches
Motor Black
(Key Switch)
Motor Black
Motor Black
Motor Red
Motor Black
Green (Ground)
White (Neutral)
Hot (120V-60Hz)
(Key Switch)
Green (Ground)
White (Neutral)
Black ( Hot 120V-60Hz)
Motor Red
Black ( Hot 120V-60Hz)
Green (Ground)
Jumper wire
Key Switch
Key Switch
* One Motor
* One Key Switch
* One Motor
* One Key Switch
Reference Numbers
2001548 - Momentary key switch, surface mount
2001550 - Momentary key switch, recessed mount
Reference Numbers
2001547 - Maintained key switch, surface mount
2001549 - Maintained key switch, recessed mount
Wiring for one motor
and one key switch switch
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Motor Black
(Key Switch)
Terminal capacity: #14 AWG to #10 AWG
Blue
Yellow
Motor Black
Motor Red
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
Orange
Orange
Green (Ground)
White (Neutral)
Hot (120V-60Hz)
Warning
* One Motor
* One Key Switch
DO NOT wri e more than one operator to
a single pole swti ch. A second operator
can be wired to the second pole of a
double pole switch.
Reference Numbers
2005616 Momentary key switch, surface mount
2005614 Momentary key switch, recessed mount
DO NOT connect two swti ches to an
operator without a relay.
Key Switch
53
Operator
Electronic Controls
Designer Switches
Designer Cover Plates
Reference
Description
2005553
2005558
2005526
Designer Switch - Single Pole, Double Throw (Maintained - Ivory)
Designer Switch - Single Pole, Double Throw (Momentary - Ivory)
Designer Switch - Double Pole, Double Throw (Maintained - Ivory)
2005554
2005559
2005527
Designer Switch - Single Pole, Double Throw (Maintained - White)
Designer Switch - Single Pole, Double Throw (Momentary - White)
Designer Switch - Double Pole, Double Throw (Maintained - White)
2005549
2005555
2005525
Designer Switch - Single Pole, Double Throw (Maintained - Almond)
Designer Switch - Single Pole, Double Throw (Momentary - Almond)
Designer Switch - Double Pole, Double Throw (Maintained - Almond)
2005550
2005556
Designer Switch - Single Pole, Double Throw (Maintained - Black)
Designer Switch - Single Pole, Double Throw (Momentary - Black)
2005532
2005536
2005539
Designer Cover Plate 1 Gang, Ivory
Designer Cover Plate 2 Gang, Ivory
Designer Cover Plate 3 Gang, Ivory
2005533
2005537
2005540
Designer Cover Plate 1 Gang, White
Designer Cover Plate 2 Gang, White
Designer Cover Plate 3 Gang, White
2005528
2005534
2005538
Designer Cover Plate 1 Gang, Almond
Designer Cover Plate 2 Gang, Almond
Designer Cover Plate 3 Gang, Almond
2005529
2005535
Designer Cover Plate 1 Gang, Black
Designer Cover Plate 2 Gang, Black
Wiring for one motor
and one designer switch
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Power in
Hot
Neutral
Ground
Black
White
Green
Motor Leads
Direction 1
Direction 2
Neutral
Ground
Red
Black
White
Green
GREEN ( gron
u d)
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
BLACK ( 120v - 6h
0 z)
WHITE ( neutral )
RED direction 1
B1
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
GREEN ( ground )
Power from wall
Warning
BLAK
C direction 2
L1
DO NOT wri e more than one operator to
a single pole swti ch. A second operator
can be wired to the second pole of a
double pole swti ch.
A1
Items
WHITE ( neutral )
DO NOT connect two swti ches to an
operator wti hout a relay.
54
Operator
Electronic Controls
Toggle Switches
Items
Reference
Description
2005520
2005522
2005514
Toggle Switch - Single Pole, Double Throw (Maintained - Ivory)
Toggle Switch - Single Pole, Double Throw (Momentary - Ivory)
Toggle Switch - Double Pole, Double Throw (Maintained - Ivory)
2005521
2005523
2005515
Toggle Switch - Single Pole, Double Throw (Maintained - White)
Toggle Switch - Single Pole, Double Throw (Momentary - White)
Toggle Switch - Double Pole, Double Throw (Maintained - White)
2005516
2005518
Toggle Cover Plate 1 Gang, Ivory
Toggle Cover Plate 2 Gang, Ivory
2005517
2005519
Toggle Cover Plate 1 Gang, White
Toggle Cover Plate 2 Gang, White
Toggle Cover Plates
Wiring for one motor
and one toggle switch
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
Power in
Hot
Neutral
Ground
Black
White
Green
Motor Leads
Direction 1
Direction 2
Neutral
Ground
Red
Black
White
Green
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
GREEN ( ground )
GREEN ( ground )
Warning
Powerf rom wall
BLACK ( 120v - 60hz )
WHITE ( neutral )
DO NOT wri e more than one operator to
a single pole swti ch. A second operator
can be wri ed to the second pole of a
double pole swti ch.
BROWN
SCREW
BRASS
SCREWS
RED ( direction 1 )
DO NOT connect two swti ches to an
operator wti hout a relay.
BLACK ( direction 2 )
WHITE ( neutral )
55
Operator
Electronic Controls
Rocker Switches
Items
Reference
Reference
Switch Only
Switch Kit
2005598
2005600
2005682
2005684
Description
Rocker Switch - Single Pole, Double Throw (Maintained - White)
Rocker Switch - Single Pole, Double Throw (Momentary - White)
- Switch kit includes: switch, back plate, cover plate and mounting screws
Rocker Cover Plates
2005657
2005662
2005668
Rocker Cover Plate Kit 1 Gang White
Rocker Cover Plate Kit 2 Gang White
Rocker Cover Plate Kit 3 Gang White
-Includes cover plate, back plate and mounting screws.
Wiring for one motor
and one rocker switch
NOTICE: For installation by a qualified electrician in accordance with
national and local electrical codes, and the following instructions.
Power in
Hot
Neutral
Ground
Black
White
Green
Motor Leads
Direction 1
Direction 2
Neutral
Ground
Red
Black
White
Green
CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before
installing. Never wire energized electrical components.
Select conductors having 90 C or higher rated insulation having
sufficient ampacity in accordance with the 60 C column of National
Electrical Code R Table 310-16 or Canadian Electrical Code Table 2
Terminal capacity: #14 AWG to #10 AWG
Power from wall
Strip conductors using strip gage on switch body. DO NOT USE TIN
CONDUCTORS.
WHITE ( neutral )
RED ( direction 1 )
BLACK ( 120v - 60hz )
BLACK ( direction 2 )
GREEN ( ground )
Warning
WHITE ( neutral )
DO NOT wri e more than one operator to
a single pole swti ch. A second operator
can be wri ed to the second pole of a
double pole swti ch.
GREEN ( ground )
DO NOT connect two swti ches to an
operator wti hout a relay.
56
Operator
Electronic Controls
Transformers and Motor Cable
Items
Transformers
Motor Cable
Reference
Description
2005968
2005647
2005637
HARDWIRE - 6 AMP - 12 VOLTS
HARDWIRE - 8 AMP - 12 VOLTS
HARDWIRE - 10 AMP - 12 VOLTS
2005604
2005605
2005639
2005641
HARDWIRE - 6 AMP - 24 VOLTS
HARDWIRE - 8 AMP - 24 VOLTS
HARDWIRE - 10 AMP - 24 VOLTS
HARDWIRE - 12 AMP - 24 VOLTS
9128097
2005749
3 CONDUCTORS PLUS GROUND (white)
3 CONDUCTORS PLUS GROUND (gray)
57