Toshiba LED TUBES - the easiest way to save 11/2014

Transcription

Toshiba LED TUBES - the easiest way to save 11/2014
Toshiba LED TUBES
- the easiest way to save
energy on your installation
11/2014
Toshiba LED TUBES
Thanks to their wide LED tube range, Toshiba give you
the opportunity to save up to 65% energy on many
applications where T8 fluorescent lamps are installed.
All the requirements of your projects can be met within
the Toshiba LED tube offer. From a price and quick
return on investment perspective or a performance
one, an option exists for you.
Choosing Toshiba tube will bring you efficiency,
quality and satisfaction.
Significant facts about our
LED TUBE
2
Up to 2,300 lm and 100 lm/W
2
Up to 3,000 lm and 125 lm/W
3
Improved design: homogenous and wide
light distribution along the whole tube length
3
Improved design: homogenous and wide
light distribution along the whole tube length
4
Very efficient: up to A+
4
Very efficient: up to A++
5
Long life time: 40,000 hours
5
Long life time: 40,000 hours
Ideal for high ceilings in commercial (sales
spaces, cold rooms, common areas, stock and
archives room...) and industrial applications
Return on investment (months)
40 000 €
35 000 €
35 000 €
30 000 €
30 000 €
25 000 €
25 000 €
20 000 €
20 000 €
15 000 €
15 000 €
10 000 €
10 000 €
5 000 €
5 000 €
0€
0€
8
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 42 44
Months
- Example of calculation
- Based on an average european cost of energy of 0,16 €/kWh
Saving
Initial investment
°
Ø 28.9
COLOUR
TEMPERATURE
LUMINOUS
FLUX
OVERALL
LENGTH
1,198
588.5
(mm)
(mm)
BEAM ANGLE
DIMMING
CRI
ENERGY
LABEL
RATED
LIFETIME
LDL003D4072EU
9W
4000 K
800 lm
604 mm
150°
No
80
A+
40,000 h
LDL003D6572EU
9W
6500 K
900 lm
604 mm
150°
No
80
A+
40,000 h
LDL003D4074EU
18 W
4000 K
1,700 lm
1,213 mm
150°
No
80
A+
40,000 h
LDL003D6574EU
18 W
6500 K
1,800 lm
1,213 mm
150°
No
80
A+
40,000 h
LDL003D4075EU
23 W
4000 K
2,100 lm
1,513 mm
150°
No
80
A+
40,000 h
LDL003D6575EU
23 W
6500 K
2,300 lm
1,513 mm
150°
No
80
A+
40,000 h
E-CORE HIGH LUMEN TUBE
LIGHT DISTRIBUTION
E-CORE HIGH LUMEN TUBE is your best partner for
tube relamping project in any high ceiling applications.
Thanks to its high lumen output it enables to save a big
amount of energy without compromising on light quality.
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 42 44
Months
- Example of calculation
- Based on an average european cost of energy of 0,16 €/kWh
DIMENSIONS
90°
50
100
150
0°
200
250
60
°
1,498
Ø 28
1,198
(cd/klm)
2
DIMENSIONS
°
40 000 €
6
RATED
WATTAGE
1,500
60
(cd/klm)
PRODUCT CODE
DIMENSIONS
90°
50
100
150
0°
200
250
30
45 000 €
4
The LED TUBE lets you perfectly light up large rooms
and commercial areas. It will ensure bright light and
a low consumption of energy. It is available either
in neutral white or cold white, in 800 to 2,300 lm.
DIMENSIONS
Return on investment (months)
45 000 €
2
LIGHT DISTRIBUTION
°
Ideal for commercial (sales spaces, cold
rooms, common areas, stock and archives
room...) and parking applications
1
LED TUBE
30
1
Significant facts about our
E-CORE HIGH LUMEN TUBE
(mm)
(mm)
PRODUCT CODE
RATED
WATTAGE
COLOUR
TEMPERATURE
LUMINOUS
FLUX
OVERALL
LENGTH
BEAM ANGLE
DIMMING
CRI
ENERGY
LABEL
RATED
LIFETIME
LDL002D3074-EU
23 W
3000 K
2,160 lm
1,198 mm
160°
No
80
A+
40,000 h
LDL002D4074-EU
23 W
4000 K
2,400 lm
1,198 mm
160°
No
80
A+
40,000 h
LDL002D6574-EU
23 W
6500 K
2,400 lm
1,198 mm
160°
No
80
A+
40,000 h
LDL002D3075-EU
24 W
3000 K
2,700 lm
1,498 mm
160°
No
80
A+
40,000 h
LDL002D4075-EU
24 W
4000 K
3,000 lm
1,498 mm
160°
No
80
A++
40,000 h
LDL002D6575-EU
24 W
6500 K
3,000 lm
1,498 mm
160°
No
80
A++
40,000 h
Please read this document carefully. If you are uncertain about a step, please contact an
Please read
document carefully. If you are uncertain about a step, please contact an
electrician
forthis
support.
electrician for support.
TOSHIBA LED TUBE INSTALLATION OPTIONS
TOSHIBA LED TUBE INSTALLATION OPTIONS
information
is provided
for yourperformed
convenience.
Toshiba
disclaims to
liability
any direct, indirect
InstallationorThis
instructions
damages
in case
of installation
either
not according
theseforinstructions,
not
This information is provided for your convenience. Toshiba disclaims liability for any direct, indirect
or damages
in electrician
case of installation
according to these instructions, not
performed
by an
or in case ofperformed
conversioneither
of thenot
luminaire.
byluminaires
an electrician
or in case
of than
conversion
the luminaire.
Ifperformed
the existing
is operated
more
8 years,ofTOSHIBA
recommends a replacement of
luminaires
to avoid long
aged deterioration
lamp holders
etc.recommends a replacement of
Ifa the
existing
luminaires
is operated
more than 8ofyears,
TOSHIBA
Retrofitting inwhole
CCG
luminaire
whole
luminaires
avoid
long aged deterioration
of lamp
holders etc.
The luminaire can
still
be usedtofor
fluorescent
lamps when
the normal
starter is reinstalled.
1. Retrofitting in a CCG luminaire
The certification1.The
of
luminaire
remains
valid.for fluorescent lamps when the normal starter is reinstalled.
luminaire in
can
still be
used
Retrofitting
a CCG
luminaire
The
of luminaire
remains
valid.
Thecertification
luminaire can
still be used
for fluorescent
lamps when the normal starter is reinstalled.
The certification of luminaire remains valid.
Installation Instructions:
Installation Instructions:
• Make sure if supply
voltagesupply
and frequency
fall within product rating on lamp/package
•Installation
Make sure ifInstructions:
voltage and frequency fall within product rating on lamp/package
• Make sure that••the
supply
voltage
is
disconnected
Make
sure
that
the
supply
voltage
is disconnected
Make sure if supply voltage and frequency
fall within product rating on lamp/package
•• Remove
thelamp
conventional
lamp
• Remove the conventional
Make sure
that
the supply
voltage is disconnected
•• Replace
conventional
starter
the LED replacement
starter
delivered
with TOSHIBA LED
• Replace the conventional
starter
to the
LEDtoreplacement
starter
delivered
with
Removethe
the
conventional
lamp
TOSHIBA
LEDconventional
tube
•
Replace
the
starter
to
the
LED
replacement
starter
delivered
• Insert the TOSHIBA
LED
tube into
lamp holders and check the light distributionwith
angle
• Insert
the TOSHIBA
TOSHIBA
LED tubeLED tube into lamp holders and check the light distribution angle
tube
• Insert the TOSHIBA LED tube into lamp holders and check the light distribution angle
1
1
2
2
3
5
6
7
6
5
4
3
8
7
4
8
The LED replacement starter in the package is mandatory for operation and safety
The LED replacement starter in the package is mandatory for operation and safety
Circuit
ofstarter
retrofitted
luminaire:
The LEDdiagram
replacement
in the package
is mandatory for operation and safety
tube luminaire:
Circuit diagramFor
of1 retrofitted
luminaire:
Circuit
diagram of
retrofitted luminaire:
For 2 tubes luminaire:
LED replacement starter
For 2 tubes luminaire:
For 1 tube luminaire:
LED tube
LED replacement starter
LED replacement starter
LED tube
LED tube
L
LED replacement starter
N
LED tube
L
LED replacement starter
CCG
CCG
N
CCG
CCG
LED tube
L
N
LED replacement starter
LED tube
CCG
CCG
L
In case a parallel power factor compensation capacitor
is used in the luminaire, it will reduce
N
the power factor. Consider that power factor could
need to be adjusted according to local
regulations.
In case a parallel power factor compensation capacitor is used in the luminaire, it will reduce
LED tube only suit
mounted
ballast.
In case
a parallel
power
compensation
capacitor is
theparallel
power factor.
Consider
that power
factor
could need
to befactor
adjusted
according to local
TUBE INSTALLATION OPTIONS_ver1.0
in the luminaire,TOSHIBA
itregulations.
willLED
reduce
the power factor. Consider that power factor could need to be adjusted
used
according to local regulations.
TOSHIBA LED TUBE INSTALLATION OPTIONS_ver1.0
http://toshiba.eu/lighting
Specifications and design as of November 2014.
Specifications and design may change without further notice.
For more details about mounting, please check our webpage.