PRODUCT LIST
O2 AND CO2 ANALYSERS
Thank you for visiting our webpage.
CD-3A
Carbon Dioxide Analyzer
Introduction
The Model CD-3A Carbon Dioxide Analyzer provides a continuous
and accurate measurement of gases containing up to 15% CO2.
The Model CD-3A has the rapid response necessary for breath-bybreath analysis during respiration. It is also ideal for laboratory
applications requiring high accuracy and sensitivity.
Features:
•
•
•
•
•
Wide range—0 to 15% CO2
High accuracy and sensitivity
Rapid response—ideal for accurate breath-by breath
measurement
End Tidal CO2 Display
Microprocessor controlled—reliable, low maintenance
operation
The Gold Standard in
laboratory carbon dioxide
analysis for over 20 years,
worldwide.
Model P-61B Sensor
Capabilities
A complete Model CD-3A consists of a sensor, readout/control unit, and
cable. When the sample gas is passed through the sensor, a voltage
that is a function of the carbon dioxide concentration of the gas is
generated. This voltage is fed to the readout/control unit via a
connecting cable.
The optional R-1 (Single Channel) or R-2 (Dual Channel) Flow Control
Unit can be used to draw the sample through the sensor. Each flow
control unit contains a pump, a needle valve, and a flowmeter for each
channel. Other gas handling equipment can be used if preferred.
Model R-1 Flow Control
[Optional]
Model CD 3-A Specifications
Speed of Response:
24 or 400 milliseconds, user selectable, to 90% of final value for
a step change in carbon dioxide concentration.
Accuracy:
±0.02% carbon dioxide or 1% of the reading, whichever is larger
Sensitivity:
±0.01% carbon dioxide
Resolution:
Digital Display: ±0.01% carbon dioxide
Range:
0-15% carbon dioxide
Display:
Continuous display of CO2 concentration or End Tidal for each breath
Analog Output:
0 to 7.5V for 0 to 15% CO2
Sample Flow Rate:
10-1000 ml/min
Stability:
±0.02% carbon dioxide at 5% in 8 hours maximum drift
Sensor Tubing Connections:
(IN/OUT) 1/8 / 1/8 inch OD stainless steel
AEI Technologies, Inc.
520 East Ogden Avenue
Naperville, IL 60563
800-793-7751
630-548-3545
Fax: 630-548-3546
[email protected]
www.aeitechnologies.com
R-1/R-2
FLOW CONTROL UNIT
The AEI Technologies R-1 and R-2 Flow Controllers are commonly used as an
integral part of any gas measurement system. Either Flow Controller is
frequently used in conjunction with the S-3A Oxygen analyzer and CD-3A
Carbon Dioxide analyzer. The Model R-1 includes a flow meter, pump, and a
needle valve in a single cabinet. Model R-2 (shown above) includes 2 flow
meters, pump, and 2 needle valves.
AEI Technologies, Inc.
520 East Ogden Avenue ٠ Naperville, IL 60563
[1] 800-793-7751 ٠ [1] 630-548-3545 ٠ f:[1] 630-548-3546
[email protected] ٠ www.aeitechnologies.com
S-3A/I and S-3A/II
Oxygen Analyzers
Introduction
The Applied Electrochemistry Model S-3A
Oxygen Analyzer continuously measures the
concentration of oxygen. There are two
models: The S-3A/I Single-Channel Analyzer
and the S-3A/II Dual-Channel Analyzer. Both
instruments feature the same high accuracy,
rapid response, and fine sensitivity.
Features:
•
•
•
•
•
High
accuracy
at
all
oxygen
concentrations
Rapid response-ideal for accurate
breath-by-breath measurements
High sensitivity plus exceptional
stability—capable
of
detecting
changes of 0.001% oxygen at air
composition
Solid ceramic oxide sensing element
for
long
term
maintenance-free
operation
Single gas calibration (room air may
be used)
The Gold Standard in laboratory
oxygen analysis for over 30 years,
worldwide.
S-3A/I Single-Channel
Capabilities
A complete Model S-3A consists of a sensor,
readout/control unit, and cable. When the
sample gas is passed through the sensor, a
voltage that is a function of the oxygen
concentration of the gas is generated. This
voltage is fed to the readout/control unit via
a connecting cable.
The optional R-1 (Single Channel) or R-2
(Dual Channel) Flow Control Unit can be used
to draw the sample through the sensor. Each
flow control unit contains a pump, a needle
valve, and a flowmeter for each channel.
Other gas handling equipment can be used if
preferred.
S-3A/II Dual-Channel
Specifications
Speed of Response:
100 milliseconds to 90% of final value for a step change in oxygen concentration.
Accuracy:
±0.01% O2 on the %O2 scale, equivalent accuracy on other scales, within working range
Working Range:
Calibration gas value ±5% of full scale value
Stability:
±0.01% oxygen in 24 hours with constant temperature and pressure
Sensitivity:
±0.001% oxygen or equivalent on other scales
Resolution:
Digital Display: ±0.01 on each scale
Analog Output:
0-5V buffered output for 0-100% O2
Sample Flow Rate:
10-300 ml/min, 50-125 ml/min recommended for most applications; for other flows,
consult the factory
Flow Dependence:
±0.02% O2 at flow rates of 50-125 ml/min, calibrated at 20.61% O2 and 95 ml/min
Additional Specifications for Model S-3A/II, Channel ∆ (1-2)
Accuracy:
±0.003% O2
Stability:
±0.003 in any 4 hour period
Resolution:
±0.001 on the digital display
Analog Outputs:
Buffered analog output of 0-10V for 0-100% O2 on channels 1 and 2; 0 to ±10V for 0 to
±10% O2 on channel ∆ (1-2)