Technical details / Pre-installation card

Transcription

Technical details / Pre-installation card
Art. F03
PRE-INSTALLATION CARD
(mm 1800 x 900)
with tap on rim of bathtub
Left-side Model
Right-side Model
90
0
90
0
0
80
with tap on rim of bathtub
18
00
585
585
1
8
20 60
0
00 60
8
16
80
80
1/2"
1/2"
1/2"
1/2"
0
400
30
400
15
00
55
0
0
55
Measurements in mm.
- Hot water connection for 1/2” tap fittings
- Cold water connection for 1/2” tap fittings"
- IPX5 box with PG13.5 and PG9 cable clamps
Siphon
97
67101022300
2011.01
- Electrical connection
- Alarm system connection
N.B. Measurements must be taken once the floors and walls are finished.
160
INSTALLATION WITH THREE SIDES AGAINST WALL: prepare a recess of width equal to the corresponding dimension of the product, plus 1.5 cm.
INSTALLATION OF THE BUILT-IN BATHTUB
Before building the perimetre walls, it is advisable to position the bathtub and make the necessary connections.
The recess between the wall and the external edge of the bathtub must be of a maximum of 1.5 cm.
A full-length removable panel must be provided along the front of the tub, allowing inspection and ventilation of the whirlpool system.
‑The panel must be fastened securely in place (e.g. with screws) so that a tool must be used to remove it, as provided for by current safety standards.
Net
Weight
Kg.
58
Water
Content (1)
lt.
210
Art. F03
HYDRAULIC CHARACTERISTICS
Floor
Load
Kg/m2
Hydromassage
227,12
Delivery
Weight
Kg.
87
Delivery
Volume
m3
Jets N.
Water
Capacity l/m.
6
200
1,51
Air
Flow l/m.
280
8
300
ELECTRICAL CHARACTERISTICS
Art.
Whirlpool
Mod.
BASIC-J
1WBX38
BASIC-E
1WLX38
TOP+Hydrosil.
1WLI38
TOP+Heater
+Hydrosilence
3WLA28
V
Hz
Installed
Power
kW
0,95
230
50
1,2
2,6
OPTIONAL
Art.
K074-Cromoexperience
TOP+Hydrosilence+Cromoexperience
TOP+Hydrosil.+Heater+Cromoexp.
Whirlpool
Art.
1LDX18
2WLI28
3WLA28
V
Hz
230
50
Installed Power
kW
0,09
1,4
2,6
(1) - At overflow level
1/2
1
ART. F03
1800
900
900
A
445
460
900
A
455
100
B
B
700
585
525
425
45
1570
TOP
52
S - Remote Control
- Dispenser cap
(Ø 50)
P - Electric Control Panel
60
33
550
BASIC
69mm
P - Electric Control Panel
D - Dispenser ( Ø 75 )
A - Air Regulation ( Ø 60 )
42mm
178
B-B
120
1120
A-A
15
178
52
CROMOEXPERIENCE
C -Electric Control Panel
33
730
S
225
P
60
313
D
A
225
ELECTRICAL INSTALLATION
• The electrical power supply system must be in compliance with national
statutory regulations.
• The product must be connected to the mains power via an omnipolar switch (I)
with an opening between contacts that guarantees complete disconnection in
excess voltage category III conditions (minimum 3 mm), installed outside areas
0,1,2,3 (IEC 60364-7-701).
• Make certain the appliance is connected to the power source by way of a
residual current device with minimum threshold =30 mA.
• The electrical connection (
) must include a connection to the earth
system and must be:
- permanent
- able to handle the rated current (see data plate).
- specified to liquids ingress protection category IPX5.
50
50
60
120
900
53
60
P
C
225
Connection for alarm system
The product is prewired for connection to the bathroom alarm system (open/close
contact, voltage-free).
HYDRAULIC INSTALLATION
Prepare hot and cold water connections for water supply and the drain
connection.
When the water from the main is hard water, the installation of a water-softener is
advisable to ensure the efficient working of the hydromassage.
The maximum capacity of the overflow is 20 l/min.
BATHTUBS WITH COMBINED OVERFLOW AND FILLER SPOUT
A DB type device must be installed at least 150 mm above the bathtub rim in
accordance with EN 1717 standard.
EQUIPOTENTIAL BONDING
The appliance must be equipotentially bonded by making the connection to the
terminal positioned at the base of the electric motor/pump unit.
D a t a a n d s p e c i f i c a t i o n s g i v e n a r e n o t b i n d i n g . Te u c o G u z z i n i S p a r e s e r v e s t h e r i g h t t o m a k e c h a n g e s d e e m e d a p p r o p r i a t e w i t h o u t p r i o r n o t i c e o r o b l i g a t i o n t o u p d a t e .
2
2/2