Nova Energy & Automation Imaging Suite Power Systems Nuclear

Transcription

Nova Energy & Automation Imaging Suite Power Systems Nuclear
Nova Energy & Automation Imaging Suite Power Systems
Nuclear Camera Main Disconnect Panel
PROJECT NAME
The Nova Main Disconnect Panel is an integrated Main Circuit
Breaker Panel with Emergency Off Accessories and related
controls specifically designed to meet the requirements of medical
imaging installations. The internal controls provide a safe, low
voltage interface between the imaging equipment, control, UPS,
and room line voltage.
CATALOG NUMBER
NEA-43030-5W-UV(120AC)-NM-HCN
NOTES
The Nova Imaging Suite Power System is a prescribed solution for
the power requirements of GE Nuclear Camera 480V Imaging
installations. The NEA43030-5W-UV(120AC)-NM-HC/N can be
identified on the GE Healthcare Drawings: Sheet E1 Right
Column  Junction Point Descriptions  A  Main Disconnect:
Equal to GEX640NM25A480V
FEATURES:
• Integrated design
• Utilizes heavy duty Square D Circuit Breaker to
handle inrush currents.
• Listed to UL508A and cUL to conform to NEC.
• Labeled to conform to NFPA99, NFPA-70.
• Provides Short Circuit and Overload Protection
• Provides differential protection
• Internally derived Emergency Off Control
Voltage
• Neutral Block and Ground Block
• Single point main disconnect and termination
point
• Factory wired to match imaging equipment and
tested
• Manufactured in the USA
• UPS Controls Integrated into Panel
The Nova Imaging Suite Power Systems exceed the standard
power requirements set forth by the Medical Imaging Equipment
design guides (Siemens, Toshiba, Hitachi, GE, and Philips).
Optional features include Emergency Off, Shunt Trip,
Undervoltage Detection, Fail Safe Energy Storage, Enhanced Short
Circuit Current Rating, 100% rated Circuit Breakers, Auto Restart,
Earth Leakage Detection, Ground Fault Detection, and Power
Quality Monitoring.
Figure 1: Photo of completed Nova MDP Panel
Table 1: Control Panel Ordering Information
Figure 2: Typical One Line Diagram
CLASS
NEA
-
VOLTAGE
PHASE
MAIN CB [1]
CURRENT
RATING
4 = 480V
3 = 3 POLE
030 = 30 A
NEUTRAL
-
5W = 3 PHASE, 1
NEUTRAL, 1
GROUND
MAIN CB
ACCESSORIES
UV(120AC) =
UNDERVOLTAGE
TRIP 120V AC
PANEL ACCESSORIES
-
NM = NUCLEAR CAMERA
ACCESSORIES
ENCLOSURE
DESCRIPTION
ENCLOSURE
SIZE
HC = HINGE
NEMA 4
ENCLOSURE
N = 16” W X 24”
H X 06” D
NOVA 1-414-939-NOVA | Fax: 262-364-2279 | Web: www.novaautomation.net |
Nova Energy & Automation Imaging Suite Power Systems
Main Disconnect Panel
SPECIFICATIONS:
Item
Specification
General
Performance
Application
Main Disconnect Panel for Nucleare Camera Medical Imaging Equipment
Input Current Rating
480/ 277VAC, 3 Phase
5-Wire: 3 Phase Conductors + Neutral + Ground
Or 4 Wire 3 Phase Conductors + Ground
30A As indicated in table 1 Main CB [1]
Output Voltage
480/277 VAC, 3 Phase (follows input voltage)
Control Voltage
Internally derived 24VDC
Emergency Off Accessories
120VAC Undervoltage Trip as indicated in table 1 Main CB Accessories
Operator Controls
Compatible with 120VAC and Low Voltage EPO operator devices
Compatible Estop Buttons
ESTOP22, 2 NO & 2 NC Contacts
Input Voltage
Control
Details
UPS
Integral 12VDC control voltage and alarms for GE 20kVA UPS or Eaton 6kVA UPS
Rating
Grounding
Isolated and non isolated Ground Bar
Physical
Short Circuit Current Protection
Dimensions
5W Systems: 35kAIC, (Enhanced SCCR rating optional)
16" W x 24" H x 6" D
Weight
Enclosure
Certification
45 lbs
Nema 4 Enclosure. 16 Ga Carbon Steel, all rounded corners, Powder Coated in
textured paint code RAL 7035
Certification
ETL, cETL
Material Usage
RoHS compliant; no mercury
Environment
Indoor use
DIMENSIONS:
NOVA 1-414-939-NOVA | Fax: 262-364-2279 | Web: www.novaautomation.net |