Integrated System Platform

Transcription

Integrated System Platform
™
Integrated System Platform
DAB-801
Q-Sys™ Amplifier and I/O Frame Backup Accessory
Features
• One DAB-801 unit can provide N+1 instantaneous 2-channel
switchover redundancy for up to 8 amplifier output channels
• Two DAB-801 units can be cascaded to provide 2 or
4-channel switchover redundancy for up to 16 amplifier
output channels
• Automatic detection & switchover between inputs from
Primary and Backup I/O Frames, in case of failure “upstream”
• Fault tolerant control & monitoring of each DAB-801 is
available using simultaneous GPIO terminals connected to
both Primary and Backup I/O Frames
• Two additional non-networked analog “high line” level inputs
provide emergency evacuation signal which can override all
other input signals
• QSC Dataport Connectors and High Current Terminal Blocks
for easy & reliable installation
• Q-Sys technical support is available 24/7 - worldwide
The purpose of the DataPort Amplifier
Backup Panel is to provide redundancy,
emergency paging, and other functionality
required for many Life-Safety & Evacuation
or mission-critical audio systems.
monitored by Q-Sys along with the power-on
status of the backup amplifier. Periodic full
tests of the backup system can be
programmed to ensure signal integrity and
meet regulatory requirements.
The DAB-801 extends the Q-Sys fault-tolerant
backup capability to include any QSC
DataPort power amplifier and I/O Frames
populated with Q-Sys DataPort cards. The
DAB-801 provides the ability to add true N+1
amplifier redundancy to any Q-Sys system,
plus the ability to automatically switch
amplifier input sources from a primary I/O
Frame to a backup I/O Frame.
Additionally two analog “high line” level
inputs allow for direct connection of a
carbon-type microphone, or a linelevel
pre-recorded message for emergency
evacuation paging which can then override
all other input signals. A normal low
impedance paging microphone may also be
connected with the addition of an external
microphone preamp.
A single DAB-801 supports four 2-channel
primary amplifiers with one 2-channel backup
amplifier, or two 4-channel primary amplifiers
with one 4-channel backup amplifier. Two
DAB- 801s can be stacked to provide double
the primary amplifier redundancy.
Using these analog inputs, each DAB-801
has two priority modes, Alarm and Page.
The Alarm input overrides all other signals,
and is used for major emergencies. The
Page input overrides all signals except the
Alarm input, and can be used for other
announcements. These inputs can be
assigned to any combination of amplifier
channels, and can be activated with either a
standard contact closure or +12VDC trigger
voltage from the fire alarm panel.
Two D-Sub 15 pin connections allow direct
connection to a pair of Q-Sys I/O Frames for
full control and monitoring of the DAB-801
through the Q-Sys Designer software. All
primary amplifiers are continuously
The DAB-801 is easily integrated into a
Q-Sys based audio system. Mounted onto
the rear of a rack, the DAB-801 minimizes
rack space consumption. AC line
connection is fast and easy with an IEC
style quick-disconnect and locking bracket
to ensure reliable AC mains connection. A
one world power supply operates on
100-240VAC, 50/60Hz.
By using QSC standard HD-15 DataPort
connectors and high current detachable
terminal blocks, the DAB-801 provides an
easy to install connector set.
Various LED indicators alert the user to
current panel status. The LEDs include an
AC power indicator, I/O Frame power status
indicators, amplifier power status indicators,
I/O Frame failure indicators, and amplifier
failure indicators.
Each DAB-801 connects up to eight
loudspeaker circuits, which may also be
100V transformer isolated.
™
Legend:
Single I/O Frame (pictured here with 2-Channel amplifiers)
2-CH DataPort cable / bi-directional
Audio Cable
Q-Lan Network
Speaker Lines / Hi-Z or Low-Z
GPI/O Cable
Q-Sys LAN
PRIMARY Q-Sys I/O Frame
2-CH
DataPorts
GPIO
Loudspeaker circuits
Mic Pre
Emergency Page Mic
DAB
801
Pre-recorded Emergency Message
PRIMARY Dataport 2-CH Amplifiers
CH1
ON
10
12
70V
CH2
CLIP
-10dB
8
6
14
4
CH1
ON
10
12
6
CH1
ON
10
12
70V
6
CH1
10
12
70V
CH2
CLIP
-10dB
8
6
14
18
CX3 0 2 V
DIRECT
(35dB)
CH1
8
(35dB)
6
DIRECT
70V
4
2
4
4
2
(35dB)
0
ATTEN
10
12
PARALLEL
8
6
14
4
2
24
POWER
0
(35dB)
8
6
24
18
SIGNAL
2
24
AMPLIFIER
0
CH2
-20dB
18
CX3 0 2 V
0
ATTEN
CLIP
-10dB
8
14
4
2
24
BRIDGE
10
12
6
18
SIGNAL
POWER
0
ATTEN
10
18
SIGNAL
POWER
0
(35dB)
ATTEN
ON
10
12
14
-20dB
4
2
24
AMPLIFIER
12
14
-20dB
4
2
24
AMPLIFIER
BRIDGE
ON
6
(35dB)
ATTEN
PARALLEL
CH2
CLIP
-10dB
8
14
18
CX3 0 2 V
DIRECT
8
24
ATTEN
BRIDGE
BACKUP Dataport 2-CH Amplifier
10
12
14
18
SIGNAL
POWER
0
(35dB)
0
ATTEN
PARALLEL
CH2
-20dB
4
2
24
AMPLIFIER
CLIP
-10dB
8
14
18
CX3 0 2 V
70V
4
2
(35dB)
ATTEN
BRIDGE
DIRECT
6
24
POWER
0
(35dB)
8
18
SIGNAL
2
24
AMPLIFIER
10
12
14
-20dB
18
CX3 0 2 V
DIRECT
0
(35dB)
ATTEN
ATTEN
PARALLEL
BRIDGE
PARALLEL
Backup I/O Frame (pictured here with 4-Channel amplifiers)
Q-Lan Network
BACKUP Q-Sys I/O Frame
2-CH
DataPorts
PRIMARY Q-Sys I/O Frame
2-CH
DataPorts
GPIO
Loudspeaker circuits
Mic Pre
Emergency Page Mic
DAB
801
Pre-recorded Emergency Message
PRIMARY Dataport 4-CH Amplifiers
CH1
2
CLIP
(31dB)
ATTEN
BACKUP Dataport 4-CH Amplifier
CH1
CH1
ON
12
10
70V
AMPLIFIER
(35dB)
10
ON
0
10
12
CX404
PROFESSIONAL AMPLIFIER
14
6
2
O0
(31dB)
ATTEN
0
SIG
10
12
8
6
14
2
O0
(31dB)
ATTEN
0
10
12
8
6
18
24
CH4
-10dB
-20dB
PAR
14
18
24
CLIP
3&4
BRDG
10
12
8
18
3
POWER
1&2
SIG
4
2
(35dB)
ATTEN
PARALLEL
-20dB
6
24
BRIDGE
8
18
SIGNAL
POWER
0
ATTEN
2
-10dB
12
14
-20dB
4
2
24
CLIP
CH2
CLIP
-10dB
8
6
14
18
CX3 0 2 V
DIRECT
14
8
6
4
18
24
2
O0
(31dB)
ATTEN
0
24
2
O0
(31dB)
ATTEN
0
14
0
6
14
2
O0
(31dB)
ATTEN
0
10
12
8
6
18
24
CH4
SIG
10
12
8
18
2
O0
-20dB
PAR
10
12
8
6
24
-10dB
BRDG
SIG
14
18
CLIP
3&4
-20dB
10
12
CX404
PROFESSIONAL AMPLIFIER
3
POWER
1&2
-10dB
ON
14
8
6
4
18
24
2
O0
(31dB)
ATTEN
0
24
2
O0
(31dB)
ATTEN
0
Common DAB-801 Configurations
Two linked DAB-801’s using Extension Bus
(pictured here with 2-Channel amplifiers)
Legend:
2-CH DataPort cable / bi-directional
Audio Cable
Speaker Lines / Hi-Z or Low-Z
CH1
ON
12
10
70V
CH2
CLIP
-10dB
8
6
14
6
4
2
24
POWER
0
(35dB)
8
18
SIGNAL
2
24
AMPLIFIER
10
12
14
-20dB
4
18
CX3 0 2 V
DIRECT
0
(35dB)
ATTEN
ATTEN
BRIDGE
PARALLEL
GPI/O Cable
CH1
ON
10
12
Q-Sys LAN
70V
CH2
CLIP
-10dB
8
6
14
6
4
2
24
POWER
0
(35dB)
8
18
SIGNAL
2
24
AMPLIFIER
10
12
14
-20dB
4
18
CX3 0 2 V
DIRECT
0
(35dB)
ATTEN
ATTEN
BRIDGE
PARALLEL
CH1
ON
10
12
70V
CH2
CLIP
-10dB
8
6
14
18
CX3 0 2 V
DIRECT
8
6
18
SIGNAL
4
2
24
POWER
0
(35dB)
10
12
14
-20dB
4
2
24
AMPLIFIER
0
(35dB)
ATTEN
ATTEN
BRIDGE
PARALLEL
CH1
ON
10
12
70V
CH2
CLIP
-10dB
8
6
14
12
4
6
4
2
24
POWER
0
(35dB)
8
18
SIGNAL
2
24
AMPLIFIER
10
14
-20dB
18
CX3 0 2 V
DIRECT
0
(35dB)
ATTEN
ATTEN
BRIDGE
PARALLEL
PRIMARY Dataport 2-CH Amplifiers
Loudspeaker circuits
DAB
801
GPIO
Speaker
Extension
Bus
2-CH
DataPorts
BACKUP Q-Sys I/O Frame
Control
Extension
Bus
Q-Lan Network
PRIMARY Q-Sys I/O Frame
GPIO
2-CH
DataPorts
Loudspeaker circuits
DAB
801
PRIMARY Dataport 2-CH Amplifiers
CH1
ON
10
12
70V
6
CH1
ON
10
12
6
BACKUP Dataport 2-CH Amplifier
CH1
ON
10
12
70V
6
CH1
12
10
70V
AMPLIFIER
CH2
CLIP
-10dB
8
6
14
18
CX3 0 2 V
DIRECT
(35dB)
10
12
6
(35dB)
ATTEN
PARALLEL
10
18
CX3 0 2 V
0
DIRECT
70V
AMPLIFIER
12
(35dB)
10
18
SIGNAL
4
2
24
POWER
0
(35dB)
ATTEN
ATTEN
BRIDGE
8
6
14
-20dB
4
2
24
PARALLEL
0
8
6
4
2
(35dB)
ATTEN
CH2
CLIP
-10dB
8
6
14
4
2
24
BRIDGE
8
18
SIGNAL
POWER
0
ATTEN
CH1
ON
12
14
-20dB
4
2
24
10
24
BRIDGE
ON
12
14
18
SIGNAL
POWER
0
(35dB)
ATTEN
PARALLEL
10
0
8
6
4
2
(35dB)
ATTEN
CH2
-20dB
4
2
24
AMPLIFIER
CLIP
-10dB
8
14
18
CX3 0 2 V
DIRECT
12
14
24
BRIDGE
PARALLEL
0
8
6
4
2
(35dB)
ATTEN
18
SIGNAL
POWER
0
(35dB)
ATTEN
10
24
CH2
-20dB
4
2
24
AMPLIFIER
CLIP
-10dB
8
14
18
CX3 0 2 V
70V
12
14
18
SIGNAL
POWER
0
(35dB)
ATTEN
BRIDGE
DIRECT
CH2
-20dB
4
2
24
AMPLIFIER
CLIP
-10dB
8
14
18
CX3 0 2 V
DIRECT
PARALLEL
0
™
Specifications
DAB-801
Connectors
Input
Output
Other
6 Position “Euro” or “Phoenix” type, QSC DataPort (HD-15), QSC GPIO (DB-15).
QSC DataPort (HD-15), 8 position high current “Euro” or “Phoenix” type.
Control Extension Bus (DB-37), IEC type AC Inlet.
Controls
Page Assignment: 8 position “dip” type toggle switch
Page/Alarm Inputs
Balanced 5k ohm, 3 Vrms.
LED Indicators
Power (blue, 1 each).
NORMAL (green, 8 each, 1 per primary DP).
FAULT (red, 8 each, 1 per primary DP).
BACKUP ACTIVE (yellow, 6 each, 1 per backup DP)
Maximum Amplifier Ratings
1200 W per channel
Power Requirements
100 – 240 VAC, 50 – 60 Hz, 12 W max.
Operating Temperature (Tma)
0˚C – 40˚C non condensing
Dimensions (HWD)
7" (17.8 cm) 4 RU x 19" (48.3 cm) rack mounting x 2" (5.1 cm)
Weight (net/shipping)
7.8 lb (3.5 kg) / 10.8 lb (5kg)
17.14±0.0
[435.3±0.3]
6.96±0.0
[176.8±0.3]
FRONT VIEW
REAR VIEW
SCALE: 1:1
please recycle
©2011 QSC Audio Products, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC Audio Products, LLC in the U.S. Patent and Trademark office and
other countries. Q-Sys is a trademark of QSC Audio Products, LLC.
1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174
Q-Sys DAB-801 Spec Sheet - 05/09/11
qscaudio.com