IN STOCK - Okonite
Transcription
IN STOCK - Okonite
Bulletin OSL OKONITE CABLES IN STOCK FOR IMMEDIATE DELIVERY Portland Minneapolis Boston Hartford Cumberland Detroit Ramsey H.Q. New York Paterson Cleveland Philadelphia Pittsburgh Chicago San Francisco Salt Lake Denver Kansas City Cincinnati Washington Richmond Santa Maria Charlotte Phoenix Orangeburg Cable Los Angeles Birmingham Atlanta Orangeburg Compound Dallas Manufacturing Plant Sales Office Service Center Houston New Orleans Tampa THE OKONITE COMPANY 102 Hilltop Road, Ramsey, New Jersey 07446 • Phone 201.825.0300 • www.okonite.com NEED CABLE IN A HURRY? Okonite maintains an in-stock inventory of the products shown in these pages, identified by catalog number. The products used in this bulletin are stocked in our service centers which are linked via an on-line computer network with our district sales offices and manufacturing plants to provide up-to-the-minute in-stock and stock replenishment information. Your local Okonite office and service center, listed below, are ready to assist you with information and to expedite your cable selection. In addition, they will be able to discuss your needs regarding other sizes and types of instrumentation cables as well as a full range of power and control cables. OKONITE DISTRICT SALES OFFICES AND SERVICE CENTERS Visit us on the internet www.okonite.com Atlanta District Office 645 Molly Lane Suite 120 Woodstock, GA 30189 (770) 928-9778 FAX: (770) 928-0913 E-Mail: [email protected] Denver District Office 636 Coffman Street Suite 201 Longmont, 80501 (303) 772-3517 FAX: (303) 772-3513 E-Mail: [email protected] Birmingham District Office 1976 Gadsden Highway Suite 145 Birmingham, AL 35235 (205) 655-0390 FAX: (205) 655-0393 E-Mail: [email protected] Boston District Office 169 South River Road Bedford, NH 0311 o (603) 625-1900 (781) 749-3374 FAX: (603) 624-2252 E-Mail: [email protected] Charlotte District Office 11111 Carmel Commons Blvd. Suite 140 Charlotte, NC 28226 (704) 542-1572 FAX: (704) 541-6183 E-Mail: [email protected] Hartford District Office 169 South River Road Bedford, NH 0311 o (860) 258-1900 FAX: (860) 258-1903 E-Mail: [email protected] Chicago District Office 2280 White Oak Circle, Suite 106 Aurora, IL 60502 (630) 961-3100 FAX: (630) 961-3273 E-Mail: [email protected] Cincinnati District Office 11260 Chester Road, Suite 650 Cincinnati, OH 45246 (513) 771-2122 FAX: (513) 771-2126 E-Mail: [email protected] Cleveland District Office 3926 Clock Pointe Trail, Suite 101 Stow, OH 44224 (330) 926-9181 FAX: (330) 926-9183 E-Mail: [email protected] Dallas District Office 2220 San Jacinto Blvd. Suite #125 Denton, TX 76205 (940) 383-1967 FAX: (940) 383-8447 E-Mail: [email protected] © 2016 The Okonite Company co Houston District Office and Service Center 802 Century Plaza Houston, TX 77073 (281) 821-5500 FAX: (281) 821-7855 E-Mail: [email protected] Kansas City District Office and Service Center 2631 South 96th Street Edwardsville, KS 66111 (913) 422-6958 FAX: (913) 422-1647 E-Mail: [email protected] Los Angeles District Office 340 Golden Shore, Suite 400 Long Beach, CA 90802 (562) 590-3070 FAX: (562) 590-3139 E-Mail: [email protected] Minneapolis District Office 16795 Country Road 24 Suite 110 Plymouth, MN 55447 (763) 432-3818 FAX: (763) 432-3811 E-Mail: [email protected] New Orleans District Office and Service Center 101 Delta Drive, Suite J St. Rose, LA 70087 (504) 467-1920 FAX: (504) 467-1926 E-Mail: [email protected] New York District Office Three Garret Mountain Plaza, St. 304 Woodland, NJ 07424 NJ (973) 742-8040 •NY (212) 239-0660 FAX: (973) 742-2156 E-Mail: [email protected] Philadelphia District Office 501 Cambria Ave., Suite 151 Bensalem, PA 19020 (215) 604-1565 FAX: (856) 604-1564 E-Mail: [email protected] Phoenix District Office 633 E. Ray Road, Suite 117 Gilbert, Arizona 85296 (480) 838-8596 FAX: (480) 897-8924 E-Mail: [email protected] Pittsburgh Service Center 120 Solar Drive Imperial, PA 15126 (724) 899-4300 FAX: (724) 899-4320 E-Mail: [email protected] Portland District Office and Service Center 6777 S.W. Bonita Road, Suite 150 Portland, OR 97224 (503) 598-0598 FAX: (503) 620-7447 E-Mail: [email protected] Salt Lake District Office 5955 S. Redwood Road Suite 200 Taylorsville, UT 84123 (801) 262-1993 FAX: (801) 262-3167 E-Mail: [email protected] San Francisco District Office 2440 Camino Ramon, Suite 315 San Ramon, CA 94583 (925) 830-0801 FAX: (925) 830-0954 E-Mail: [email protected] Tampa District Office 10002 Princess Palm Avenue Suite 104 Tampa, FL 33619 (813) 627-9400 FAX: (813) 246-4705 E-Mail: [email protected] Washington District Office 7000 Infantry Ridge Rd., Suite 100A Manassas, VA 20109 (703) 904-9494 FAX: (703) 904-1610 E-Mail: [email protected] International Sales Hilltop Road P.O. Box 340 Ramsey, NJ 07446 (201) 825-0300 FAX: (201) 825-9026 [email protected] INDEX GLOSSARY OF TERMS AND DEFINITIONS ............................................. 5-6 LOW VOLTAGE CABLES TO 2kV Single Conductor Cables Okoguard Okolon TS-CPE Type RHH or RHW-2 or USE-2, VW-1 600V RW-90 ...... 7 Okoguard Okolon TS-CPE Type RHH or RHW-2, 2000V .......................................... 7 Multi Conductor Cables Okonite-FMR Okoseal Type TC-ER 600V/1000V ....................................................... 8 X-Olene - Okoseal Type TC-ER Control Cable (XHHW-2) 600V ................................ 9 C-L-X Type MC & MC-HL for CT USE (XHHW-2) 600V/1000V Control Cable ......... 10 C-L-X Type MC-HL for CT USE (XHHW-2) 600V/1000V .......................................... 11 MEDIUM VOLTAGE POWER CABLES 5kV AND ABOVE Single Conductor Cables Okoguard Non-Shielded Okolon TS-CPE FAA L-824 Type B Airport Lighting Cable 12 Okoguard Non-Shielded Okolon TS-CPE Type MV-90 (CT USE) 2.4kV ................. 12 Okoguard Shielded Okoseal Type MV-105 5/8kV ...................................................... 12 Okoguard Shielded Okoseal Type MV-105 {CT USE) 5/8kV ................................... 13 Okoguard Shielded Okoseal Type MV-105 15kV ..................................................... 13 Okoguard Shielded Okolon TS-CPE Type MV-105 (CT USE) 15kV ........................ 14 Okoguard Shielded Okoseal Type MV-105 (CT USE) 15kV .................................... 14 Okoguard Shielded Okoseal Type MV-105 35kV ...................................................... 15 Okoguard Shielded Okoseal 69kV ........................................................................... 15 Okoguard 105°C URO-J 15, 25, 35kV ...................................................................... 16 Multi Conductor Cables Okoguard Non-Shielded C-L-X Type MV-90 or MC-HL (CT USE) 2.4kV ................. 17 Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 5/8kV ...................... 17 Okoguard Shielded C-L-X Type MV-105 or MC-HL {CT USE) 15kV ....................... 18 Okoguard Shielded Okoseal Type MV-105 (CT USE) 5/8kV & 15kV ......................... 18 INSTRUMENTATION CABLES Okoseal Type P-OS 300V ........................................................................................ 19 Okoseal Type SP-OS 300V ........................ ............................................ ................. 19 Okoseal-N Type P-OS 600V .................................................................................... 20 Okoseal-N Type SP-OS 600V .................................................................................. 20 Okoseal Type P-OS Thermocouple 300V ................................................................ 21 C-L-X Okoseal Type P-OS Thermocouple 300V ........................................................21 Okoseal Type P-OS/SP-OS C-L-X 300V .................................................................. 22 Okoseal-N Type P-OS/SP-OS C-L-X Type MC or MC-HL 600V/1000V ................... 23 INDEX SPECIAL PURPOSE CABLES X-Ray 65-250kV DC .................................................................................................. 24 Okoguard Aerial Jumper Cable 15kV ....................................................................... 24 Solid Type PILC 15kV .............................................................................................. 24 RAILROAD AND TRANSIT SYSTEM CABLES Signal Cable ............................................................................................................. 25 Type DEL .................................................................................................................. 25 Track Wire ................................................................................................................ 25 Case Wire ................................................................................................................. 25 Tower and Case Wire ............................................................................................... 26 Nylon Braid Case Wire ............................................................................................. 26 Okolon TS-CPE Line Wire ........................................................................................ 26 Okolene Line Wire .................................................................................................... 26 SPLICING AND TERMINATING PRODUCTS C-L-X Terminating Tool Kit ....................................................................................... 27 Removing the C-L-X Armor ...................................................................................... 28 Color Code Tables ............................................................................................ 29 - 30 Miscellaneous Information ........................................................................................ 31 GLOSSARY INDUSTRY ASSOCIATIONS ABS American Bureau of Shipping. AEIC Association of Edison Illuminating Companies. ANSI American National Standards Institute. AREMA American Railway Engineering and Maintenance of Way Association ASTM American Society for Testing and Materials. ICEA Insulated Cable Engineers Association (former1y IPCEA). IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers. NEC National Electrical Code. NEMA National Electrical Manufacturers Association. NFPA National Fire Protection Association. GOVERNMENT AGENCIES OSHA Occupational Safety and Health Act administered by U.S. Dept. of Labor which establishes employee safety standards in all industrial and commercial establishments. RUS Rural Utility Systems of the U.S. Department of Agriculture, former1y REA. FAA Federal Aviation Administration EPA Environmental Protection Agency DOE Department of Energy FERC Federal Energy Regulatory Commission OKONITE REGISTERED TRADE NAMES C-L-X® Continuous-Lightweight-Exterior. Welded and corrugated, impervious metallic sheathed cables. LOXARMOR® An inter1ocked "S" shaped armor cable covering, normally galvanized steel or aluminum. OKOBON® A moisture resistant cable finish consisting of an aluminum/ copolymer tape fused to itself and to an overall jacket. OKOBUS Fieldbus instrumentation cable. OKOCLEAR TP® {TPPO} Thermoplastic Polyolefin low smoke/zero halogen jacket compound. OKOCLEAR TS® Thermosetting Polyolefin low smoke/zero halogen jacket compound. OKOGUARD® Okonite's exclusive ethylene-propylene rubber (EPR) based, thermosetting insulation, with an optimum balance of electrical and physical properties unequaled in other solid dielectrics, used on power cables rated 600 V and above. (43rd Anniversary- 2011) OKOLENE® Thermoplastic polyethylene or polypropylene based insulation or jacket compound. OKONITE® Okonite's exdusive ethylene propylene rubber (EPR) based, thermosetting insulation used up to 2000V. OKONITE-FMR® Okonite's exdusive flame and moisture resistant ethylene propylene rubber (EPR) insulation used up to 2000V. OKOGUARD-OKOLON® Composite insulation system consisting of a layer of EPR and covered with a chlorinated thermoset compound. OKO-PACK® Okonite's unique compact round conductor shape and design. OKOSEAL® A PVC insulation or jacketing compound with excellent resistance to flame and most chemicals. OKOSEAL-N® PVC insulated and nylon jacketed low voltage conductors, Type THHN, THWN-2 and TFN. OKOLON TP-CPE® Thermoplastic moisture resistant CPE compound serving as an outer jacket. OKOLON TS-CPE® Thermoset moisture resistant flame retardant CPE outer jacket. OKOTHERM® Heat resistant silicone rubber based insulation for use in high temperature locations. OKOZEL® Okonite's name for its ETFE based flame and radiation resistant insulating and jacketing compound. P-30® Okolene-Okoseal insulated 600V multiple and single conductor control cable. P-45® Okolene-Okoseal Insulated 1000V Multiple Conductor Control Cable. X-OLENE® Okonite's name for its XLPE insulation and jacket. STANDARD TERMS AWG American Wire Gauge, based on the circular mil system where 1 mil equals 0.001 inch. CIC Cable in Conduit for buried distribution systems. CIC Circuit Integrity flame retardant cables C-L-X-M C-L-X Marine Shipboard Cable CPE Chlorinated Polyethylene jacketing material. CSA Canadian Standards Association. An independent organization which implements and monitors the commercial and consumer electrical product standards. The CSA assures compliance to the various Canadian Electrical Code requirements. CT Designation given to cables meeting UL requirements for cable tray use. CTC Designation for Centralized Traffic Control Code Line cable. CWCMC UL's designation for 600 volt C-L-X marine shipboard cable - "continuously welded corrugated MC" cable. DEL Diesel Electric Locomotive and car wiring with Okonite insulation and Okolon jacket. EPR Ethylene Propylene Rubber insulating compound ingredient. ER Exposed Run, UL term designating cables approved for open wire applications. ETFE Modified Ethylene Tetrofluoroethylene compound (Okozel) used for insulation and jackets. FIELDBUS CABLE - High Speed digital signal transmission instrumentation cable having specific electrical characteristics. FPL Power limited Fire Protective Signal Cable (NEC Art. 760). 300V rated FMR Flame and Moisture Retardant. HL Designation given to MC and ITC cables meeting NEC and UL requirements for use in Division 1 hazardous locations. INSULATION LEVEL-100% Cable for use on grounded systems or where the system is provided with relay protection such that grounds faults will be deared as rapidly as possible but in any case within one minute. INSULATION LEVEL-133% Cable for use on ungrounded or grounded systems or where the faulted section will be de-energized in a time not exceeding one hour. ITC Instrumentation Tray Cable for instrumentation & control circuits operating ~150V and~ amps., per NEC Article 727. kcmil A unit of conductor area in thousands of circular mils. (Former1y MCM). LOCA Loss of Coolant Accident, IEEE 383 defines test requirements. LCS Longitudinal Corrugated Shield. 5 GLOSSARY (continued) MC Metal-Clad cable. NEC type designa- tion for power and control cables enclosed in a welded and corrugated metallic sheath (C-L-X), or an interlocking tape armor (Loxarmor). (Artide 330) MC-HL Metal-Clad cable listed for hazardous locations mil 0.001 inch. MV Medium Voltage cable. NEC designation for single & multiple conductor insulated cable rated 2001to35,000 volts. (NEC Article 328) NPLF Non-Power Limited Fire Protective Signal Cable (NEC Art. 760). 600V rated OKO-MARINE UL designation for non-armored Marine Shipboard Cable. PLTC Type designation for PowerLimited Tray Cable for use in Class 2 or 3 power-limited circuits; instrumentation, supervisory control, and thermocouple extension. P-NS Single pair or triad, Non Shielded, instrumentation or thermocouple extension cable. P-OS Single or multi Pairs or Triads with Overall Shield, instrumentation or thermocouple extension cable. POWER-LIMITED CIRCUIT Circuit either inherently limited requiring no overcurrent protection or limited by a combination of a power source and overcurrent protection. PVC Polyvinyl Chloride insulating and jacketing material which is usually flame retardant and resistant to many chemicals. P-104 Okonite's identification number issued by the Pennsylvania Department of Environmental Resources. RHH NEC conductor type designation for conductors with Heat resistant rubber or XLPE insulation, for use in dry locations. RHW-2 NEC conductor type designation for conductors with Heat and Moisture resistant rubber or XLPE insulation, for use in 90°C wet or dry locations. RTA Thermoplastic insulated, aluminum shielded, polyethylene jacketed communication cable. SCREEN A semiconducting nonmetallic layer used under and over the insulation of 6 power cables rated over 2kV to reduce electrical stresses and corona SEMICONDUCTING An extruded layer or tape of such resistance that when applied between two elements of a cable the adjacent surfaces of the two elements will maintain substantially the same potential. SHIELD A nonmagnetic, metallic material applied over an insulated conductor(s) to confine the electric field to the insulation. SP-OS Multiple Shielded Pairs or Triads with Overall Shield, instrumentation or thermocouple extension cable. TC NEC type designation for power and control tray cable. (Artide 336) TFN NEC conductor type designation for PVC insulated nylon jacketed conductors in sizes #18 and 16 AWG for use in dry locations. THERMOCOUPLE CABLE - A cable consisting of two dissimilar metals or alloys that, when electrically joined at one end can be used to measure temperature. These cables have no voltage rating. THHN NEC conductor type designation for PVC insulated nylon jacketed conductors for use in dry locations. THWN-2 NEC conductor type designation for PVC insulated nylon jacketed conductors for use in 90°C wet or dry locations. TPPO Thermoplastic Polyolefin, a thermoplastic jacket material with low smoke characteristics and is free of halogens. UL Underwriters Laboratories. An independent organization which examines, tests, lists and periodically inspects equipment to appropriate standards. URO-J Underground Residential distributionOkoguard (EPR) insulation-Okolene Jacket employing a concentric neutral. USE Underground Service Entrance cable. (NEC Artide 338) VERTICAL TRAY FLAME TEST Conducted per UL, IEEE or ICEA procedures to demonstrate that a single conductor (1/0 AWG and larger) or multi-conductor cable will not propagate a fire in the defined test. VOLTAGE LEVELS Power-Limited - 0-300 Volts Low Voltage - 600-2000 Volts Medium Voltage - 2400-46000 Volts High Voltage - >46 to 345kV VOLTAGE RATING kV, industry convention to identify voltage levels, phase to phase voltage. VW-1 Basic flammability test for single conductors; employs a tirrill burner applied intermittently to a Vertical Wire. XHHW-2 NEC conductor type designation for conductors with Heat and Moisture resistant thermoset insulation for use in 90°C wet or dry locations. XLPE Cross-Linked Polyethylene insulating compound. XLPO Cross Linked Polyolefin, a thermoset jacket material with low smoke characteristics and is free of halogens. Z NEC conductor type designation for conductors with ETFE insulation for use in dry locations. ZW NEC conductor type designation for conductors with ETFE insulation for use in wet or dry locations. CONDUCTOR IDENTIFICATION INFORMATION E-1 Color sequences for utility conductor identification, see Appendix E, Table E-1, ICEA Standard S-73-532, includes green and white. E-2 Color sequence for industrial conductor identification, see Appendix E, Table E-2, ICEA Standard S-73-532, exdudes green and white. METHOD-1 Conductor identification, colored compounds with tracers in accordance with the ICEA standard. METHOD-2 Conductor identification, neutral compounds with tracers in accordance with the ICEA Standard. METHOD-3 Conductor identification, neutral or single colored compounds with surface printing of numbers and color designations in accordance with the ICEA Standard. METHOD-4 Conductor identification, neutral or single colored compounds with surface printing of numbers in accordance with the ICEA Standard. METHOD-5 Conductor identification, individual color coding with braids in accordance with the ICEA Standard. LOW VOLTAGE SINGLE CONDUCTOR CABLES PDS 3:1 Specifications: UL44 & 854, ASTM B-8, 8-496, ICEA lHl5-658, CSA RW90 Catalog Number 112-24-2071 112-24-2101 112-24-2131 112-24-2191 112-24-2221 112-24-2251 112-24-2311 112-24-2351 112-24-2371 112-24-2411 112-24-2431 112-24-2471 112-24-2531 112-24-2591 112-24-2651 Conductor Size AWGorkcmil 14 12 10 8 6 4 2 1/0 2/0 4/0 250 350 500 750 1000 OKOGUARD-OKOLON TS-CPE Type RHH or RHW-2 or USE-2, VW-1 600V RW-90, Sun Res @0 Construction: One bare stranded round copper conductor, composite Okoguard EPR-Okolon TS-CPE insulation.Sizes smaller that #8 AWG are compressed round. #8 AWG and larger are compact round. Conductor Temperature: 90°C dry, 90°C wet Sizes: #14 AWG - 1000 kcmil Appllcatlon: Services. feeders, branch and control circuits for industrial, commercial and electric utility installations, wet or dry locations, direct burial (#8 AWG and larger) in raceways, underground ducts, or lashed to a messenger for aerial installation or cable tray (1/0 AWG and larger). Sizes 1/0 AWG and larger are marked "sunlight resistant, for use in cable tray". Listed by UL as Type RHH/RHW-2, USE-2, and VW-1. Listed by CSA as RW-90, -40C, FT1 (1/0 and larger FT4), outdoor. Sizes 1/0 AWG and larger pass UL 1581, and IEEE 1202 Vertical Tray Flame Test Requirements and are marked for "CT-USE", -40°C installation.. Composite Approx. Approx. Number Insulation NetWel ht of Strands Thickness-mils O.D.-lnches lbs/M' 7 45 0.17 25 45 0.19 34 7 45 7 0.21 49 7 0.27 75 60 119 75 7 0.33 173 75 7 0.38 257 7 75 0.43 414 100 19 0.56 507 100 19 0.60 766 100 19 0.70 938 130 37 0.80 1265 130 37 0.89 1.01 1750 130 37 2590 145 61 1.21 145 61 1.36 3391 OKOGUARD-OKOLON TS-CPE @0 Type RHH or RHW-2 2000V, Sun Res PDS3:10 Specillcallons: UL44, ASTM B-8, 8-496, ICEA S-95-658, CSA RW90 Catalog Number 113-24-2071 113-24-2101 113-24-2131 113-24-2191 113-24-2221 113-24-2251 113-24-2311 113-24-2351 113-24-2371 113-24-2411 113-24-2431 113-24-2471 113-24-2531 113-24-2591 Conductor Size AWGorkcmil 14 12 10 8 6 4 2 1/0 210 4/0 250 350 500 750 Construction: One bare stranded round copper conductor, composite Okoguard EPR-Okolon TS-CPE insulation. Sizes smaller that #8 AWG are compressed round. #8 AWG and larger are compact round. Conductor Temperature: 90°C dry, 90°C wet Sizes: #14 AWG - 750 kcmil Application: Services, feeders, branch and control circuits for industrial, commercial and electric utility installations, wet or dry locations, in raceways, underground ducts, or lashed to a messenger for aerial installation or cable tray (1/0 AWG and larger). Sizes 1/0 AWG and larger are marked "sunlight resistant, for use in cable tray". Listed by UL as Type RHH/RHW-2 and VW-1. Listed by CSA as RW-90, -40C, FT1 (1/0 and larger FT4), outdoor. Sizes 1/0 AWG and larger pass UL 1581, and IEEE 1202 Vertical Tray Flame Test Requirements and are marked for "CT-USE" -40°C installation. Number of Strands 7 7 7 7 7 7 7 19 19 19 37 37 37 61 Composite Insulation Thickness-mils 60 60 60 85 85 85 85 110 110 110 140 140 140 155 Approx. O.D.-lnches 0.20 0.22 0.24 0.32 0.35 0.40 0.45 0.57 0.61 0.71 0.83 0.92 1.04 1.24 Approx. NetWei ht lbs/M' 30 40 55 90 126 180 265 424 517 777 957 1286 1773 2618 7 PDS 4:5 LOW VOLTAGE MULTl CONDUCTOR CABLES @ .(~) X-OLENE - OKOSEAL TYPE TC-ER CONTROL CABLE (XHHW-2) 600V, Sun Res PDS4:8 Speclllcatlons: ICEA S-73-532, & ~58. ASTM B-8, B-496 & UL 1277, C22.2 No. 239 Catalog Number 202-31-3502 202-31-3503 202-31-3504 202-31-3505 202-31-3507 202-31-3509 202-31-3512 202-31-3602 202-31-3603 202-31-3604 202-31-3605 202-31-3607 202-31-3609 202-31-3612 202-31-3702 202-31-3703 202-31-3704 202-31-3823 202-31-3833 Conductor Size AWGorkcmil Strands 14(7x) 14(7x) 14(7x) 14(7x) 14(7x} 14(7x) 14(7x) 12{7x} 12(7x) 12(7x) 12(7x) 12(7x) 12(7x} 12(7x) 10(7x) 10(7x) 10{7x} 12(7x) 10(7x) Catalog Number 112-31-3735 112-31-3747 112-31-3759 112-31-3765 112-31-3777 112-31-3781 112-31-3785 112-31-3793 112-31-3797 112-31-3801 Conductor Size AWGorkcmil (Strands! 8(7x) 6(7x) 4(7x) 2(7x) 1/0(19x) 2/0(19x) 4/0(19x) 350(37x) 500(37x) 750(61X) Number of Conductors 2 3 4 5 7 9 12 2 3 4 5 7 9 12 2 3 4 3 3 Construction: Multiple stranded bare copper conductors, sizes smaller than #8 AWG are compressed, sizes #8 AWG and larger are compact stranded, X-Olene color coded conductors and Okoseal jacket. Conductor Temperature: 90°C wet or dry Sizes: #14 AWG - 750 kcmil Application: Feeders and branch circuits in industrial, commercial and electric utility applications; for power, lighting, control, signal, and communication circuits; indoors or outdoors, in cable trays, between cable trays and utilization equipment, in raceways, direct burial, supported by a messenger in outdoor locations, and in cable tray in Class I, Division 2 and Class II, Division 2 hazardous locations in industrial establishments only.UL listed as Type TC, "Sunliaht Resistant" and for "Direct Burial". cUL listed CIC ~ 410 AWG Green Insulated Cu Approx. Grounding Approx. Conductor Insulation Jacket NetWei ht SizeAWG Thickness-mils Thickness-mils O.D. - Inches lbs/M' 45 0.37 78 30 0.39 100 30 45 0.43 122 30 45 144 0.46 45 30 0.50 182 45 30 0.62 254 30 60 0.69 306 30 60 30 45 0.41 98 30 0.43 133 45 30 0.47 164 45 0.51 196 30 45 0.59 269 30 60 0.68 344 30 60 0.77 425 30 60 0.46 132 30 45 0.48 183 45 30 0.56 246 30 60 140 45 1#12 30 0.48 0.55 215 1#10 30 60 POWER CABLE Number of Conductors 3 3 3 3 3 3 3 3 3 3 Grounding Conductor SlzeAWG 10 8 B 6 6 6 4 3 2 1 Insulation Jacket Thickness-mils Thickness-mils 45 60 45 60 45 60 45 80 55 80 55 80 55 80 65 110 65 110 80 110 Approx. O.D. - Inches 0.66 0.74 0.81 0.97 1.17 1.26 1.47 1.88 2.13 2.56 Approx. Net Weight (lbs/M'I 313 440 578 896 1350 1639 2488 4044 5581 8206 * #8 and larger is bare compact round conductor Conductor Identification: Sizes #10 AWG & smaller ICEA Method 1, E-2 Sizes #8 AWG & larger ICEA Method 3 Printing of Numbers (1) Min. Size - UL permits partitioning of Grounding Conductor (2) Green Insulated Ground (3) Bare Uninsulated Ground 9 LOW VOLTAGE CONTROL MULTl CONDUCTOR CABLES ®• C-L·X 1-yp. MC & Mc-HL FOR CT USE (XHHW·2) 800V Control Cable, Sun Rn PD8 4(1 .. 4(14 IL & M9 lllllld • llllalln9 9hl..,._. Calli.,.,,._ (Cl X" CWClllC) IQQl11QGV ConMnadlon: Two or more ltmlded copper candudol-. llzee #8 AWG and leotw.,...,mpooclrtnrnded, ~lnsui.tiod,....,r....i9dcandudln,.,wnd wire (MC.HL ~ llllenl (• nN 7). binder •pe w core, colll.lgBled .i...,1...,, C.L..X9'*'111, wtilci.....I~-'· Ceold-Te,......_ llO'Cdry..,Ml • lbr:M:#14AWO ·#IOAWG AppllcMlon llC • llC-llL:Economcel and wreadle llllefrnl 111 a cancUt .,am; for ..m-. fwde"" and lnnob d - In ll"llUllMI and aomnenii.1 applcdo..; iio-; llghtlng, ccntml and llgnal chi.lb; lndoora ... ouldoom, In w.torctylooallon•,dn.itlN!tl, lna.1e1ray, lrn .., •"l*lnnaf~ •aetlalcallleonan oir,mld lnClwJ, DMllon2, CluaJJ,DMalon2,and awmhuenloll• bcalloi•.1)pe MC.HLlll9lndr......1n Clmllll, DMllon 1 . _ ....'*'°""9. TYPE MC CONTROL CABLE (Da. not lnc:..m praundln1 c:ondud!r) cm!OI NumlMi' llumberftl Condu2 3 4 Ii 7 Cendudal'llllG(9tranda) ~~ 641-31-3002 646-31-311GS 6"-31.aao4 &l&-31-3005 14(7lc) 14(7lc) 1417Xl 14(7lc) 14(7lc) 14(7lc) 14UKI 546-31~ 546-31~ 546-31-®12 546-31-®18 54N1~ MM1~ 548-81~ MM1~ GCe-31~ • 12 19 81 2 US:! 12(7M) a 4 II 12(hl 12(71c) 12(71c) 12(71c) 12!71Cl 12(71c) 1546-3141187 641-31.aoel &l&-31-3082 546-31~ N&ll.ron ThSGb11•mll 30 30 30 30 30 30 30 30 30 30 30 30 30 7 ll 12 18 :'17 2 3 4 30 30 30 30 30 30 30 30 546-31-3117 546-31-3182 546-31-3183 10(7K) 546-31-3184 10(7K) 546-31-3187 1 Color cadre per ICEA melhod I. Table E-2 ~~ 30 c.uc JMillll o.D.AIGllM 1hlolm1M"'9 OM OM 0.&3 0.&8 0.412 0.71 0.80 60 60 60 50 50 50 0.93 SI o:r,-- &O m 1214 0.68 0.!13 0.158 Q.$2 0.58 0.51 0.17 0.75 381 531 9411 15 189 221 2$1 324 '405 O.t9 o:n o.78 liO 60 &O 50 50 50 50 50 50 0.80 0.88 1.02 1.:17 254 308 1.86 lllO 0.91 1.CO li03 1.U 1A8 OM 0"8 0.78 721 1301 201 0.88 431 238 281 ..... = TYPE MC-HL CONTROL CABLE (lncludM grounding condudol(•)) c:.taloa Numwr 6441-31-3403 64U1"'404 ICN1-&IOll 114e41-8408 541-l11-3411 541-l11-3418 64U1-3438 54N1-8453 54N1-3454 541-l11-34Sll 541-l11-3458 GCU1-8481 54N1-8488 54N1-3491 6441-31-3603 C*AWQ tnuda) 1 1 1 1 1 1 1 llinllm'of '&it:= s 4 • 8 11 18 311 3 4 II 8 11 18 311 ICN14llOll 1 1 1 1 1 1 1 1 1 1 54N1-s5Ull 541-l11.a511 ~~ 8 11 64U1~ 10 s 4 • GftMl~!3.. /11118 3x18a.. 3•188'n #14 Gnlen IR9111nd #14 Gnen IR911111118d #14 GNen ll'alllnd #14 GNen ll'allleliad #14 Gnlen ll'alllnld Cond- ax1aa.. 3x18Bare #12 Giiien ll'alllnld #12 GNen ll'allleliad f12 Gnlen IR911"118d #12 Gnan ll'alllllllld #12 Gnen ll'allllllld 3x14a.. a.Ha.. #10 Gnlen IR9111nd #10 Giiien ll'allllllld #10 Giiien ll'alllnld ~11111111 c~ mis lncl!M 30 30 30 30 0.63 O.&a O.IS2 0.11 0.80 0.83 1.24 0.!!8 0.87 0.87 0.80 0.1119 1.02 1.37 0.82 0.117 '1111--- 30 30 30 30 30 30 30 30 30 30 30 30 O.D..- Thlolalmils liO 60 D.84 D.88 D.73 llO 0.112 0.81 1.04 1.36 0.88 0.71 0.78 0.81 1.00 1.18 1.48 llO 50 50 60 50 50 50 50 llO llO !Ill liO 60 ~::f.!I, 141 163 181 210 OM OM lllO SI lllO o.61 ~ 0.80 0.60 0"4 OM 0.73 0.12 0.91 1.04 D.73 D.78 D.811 1.llO 1.118 m;:: lllldl'I .., 180 222 ll2I Sil& 664 148 231 288 9311 4211 5111 7lJI 180G! aoo S48 .-&1 0:11 llO 30 0.88 50 588 30 0.117 50 704 Cdor Codng per ICEA Melhod 1, Tallie E-2 (fornoft11RM1rdl1! conduclo!a) 30 PDS 4:1 & 4:2 PDS 2:2 & 6:6 PDS 2:4 MEDIUM VOLTAGE SINGLE CONDUCTOR POWER CABLES PDS2:3 Specifications: UL 1072. AEIC CS8, ASTM B-496, CSA C68.3, ICEA S-93-639 Catalog Conductor Size AWGorkcmil Number 114-23-3824 1/0 114-23-3826 2/0 114-23-3832 410 114-23-3834 250 114-23-3838 350 114-23-3846 500 114-23-3873 750 5kV-133% or 8kV-100% INSULATION LEVEL Construction: One Okopact"' (compact stranded) copper conductor, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR insulation screen, bare copper shielding tape with 25% minimum over1ap, Okoseal jacket. Conductor Temperature: 105°C Sizes: 1/0 AWG - 750 kcmil Application: Feeders and branch circuits in electric utility, industrial and commercial applications; may be used in wet or dry locations, in raceways, messenger supported wiring, and in underground ducts, direct buried (if installed in a system with a grounding conductor in close proximity) or messenger supported in industrial and electric utilities. UL listed for cable tray use per NEC Article 392. Meets UL 1072, IEEE 383, IEEE 1202 & CSA C68.10 FT-4, -40C. Insulation Thickness-mils 115 115 115 115 115 115 115 Approx O.D. (in.) over: Insulation Screen 0.61 0.67 0.65 0.71 0.75 0.81 0.80 0.86 0.89 0.95 1.01 1.07 1.19 1.25 PDS2:9 OKOGUARD SHIELDED OKOSEAL 15kV Type MV-105, Sun Res Speclftcatlons: UL 1072, AEIC CS8, ASTM ~96. ICEA S-93-639 Catalog Conductor Size Number AWGorkcmll 115-23-3111 2 115-23-3115 1/0 115-23-3117 2/0 115-23-3121 4/0 115-23-3123 250 115-23-3127 350 115-23-3131 500 115-23-3135 750 115-23-3139 1000 OKOGUARD SHIELDED OKOSEAL 5/8kV @~ Type MV-105 FOR CT USE, Sun Res and CSA LISTED Insulation Thickness-mils 220 220 220 220 220 220 220 220 220 Jacket Thickness-mils 60 60 80 80 80 80 80 Approx. O.D.-ln. 0.81 0.85 0.99 1.05 1.14 1.26 1.43 Approx. Net WT. (lbs/M'} 615 720 1030 1185 1540 2055 2940 ® 133% INSULATION LEVEL Construction: One Okopact"' (compact stranded) copper conductor, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR insulation screen, bare copper shielding tape with 12.5% nominal over1ap, Okoseal jacket. Conductor Temperature: 105°C Sizes: #2 AWG - 1000 kcmil Application: Feeders and branch circuits in electric utility, industrial and commercial applications; may be used in wet or dry locations, in raceways, messenger supported wiring, and in underground ducts, direct burled (if installed in a system with a grounding conductor in close proximity) or messenger supported in industrial and electric utilities. Approx 0.0. (in~ over: Insulation creen 0.75 0.81 0.82 0.88 0.86 0.92 0.96 1.02 1.01 1.07 1.10 1.16 1.22 1.28 1.40 1.46 1.54 1.60 Jacket Thickness-mils 80 80 80 80 80 80 80 80 110 Approx. O.D.-lnches 1.00 1.07 1.11 1.20 1.26 1.35 1.47 1.64 1.85 Approx. Net Wl (lbs/M') 670 845 950 1260 1415 1790 2325 3220 4075 13 MEDIUM VOLTAGE SINGLE CONDUCTOR POWER CABLES ® PDS 2:11 Specifications: UL 1072, AEIC CS8, ASTM B-496, CSA C68.3, ICEA S-9~ Catalog Conductor Size Number AWGorkcmil 115-23-2131 500 115-23-2135 750 Insulation Thickness-mils 220 220 PDS 2:8 Specifications: UL 1072, AEIC CS8, ASTM B-496, CSA C68.3, ICEA S-9~ Catalog Conductor Size Number AWGorkcmil 115-23-3230 1/0 115-23-3232 210 115-23-3236 4/0 115-23-3238 250 115-23-3240 350 115-23-3242 500 115-23-3243 750 115-23-3244 1000 14 Insulation Thickness-mils 220 220 220 220 220 220 220 220 OKOGUARD SHIELDED OKOLON TS-CPE 15kV Type MV-105, Sun Res and FOR CT USE 133% INSULATION LEVEL Construction: One Okopact® (compact stranded) stranded copper conductor, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR insulation screen, bare copper shielding tape with 25% minimum overlap, Okolon TS-CPE jacket. Conductor Temperature: 105"C Sizes: 500-750 kcmll Application: Feeders and branch circuits in electric utility, industrial and commercial applications; may be used in wet or dry locations, in raceways, and in underground ducts.direct buried (if installed in a system with a grounding conductor in close proximity) or messenger supported in industrial and electric utilities. UL Listed for cable tray use per NEC Article 392. Meets UL 1072, IEEE 383 and IEEE 1202. Approx O.D. (in.) over: $creen Insulation 1.22 1.28 1.40 1.46 Jacket Thickness-mils .080 .080 Approx. O.D.-lnches 1.49 1.66 Approx. Net Wt. (lbs/M') 2385 3285 OKOGUARD-SHIELDED OKOSEAL 15kV Type MV-105 FOR CT USE, Sun Res 133% INSULATION LEVEL Construction: One Okopact® (compact stranded) copper conductor, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR insulation screen, copper shielding tape with 25% minimum overlap, Okoseal jacket. Conductor Temperature: 105"C Sizes: #1/0AWG-1000 kcmil Application: Feeders and branch circuits in electric utility, industrial and commercial applications; may be used in wet or dry locations, in raceways, messenger supported wiring, and in underground ducts, direct buried (if installed in a system with a grounding conductor in close proximity) or messenger supported in industrial and electric utilities. UL listed for cable tray use per NEC Article392. Meets UL 1072, IEEE383, IEEE 1202and CSAC68.10, FT4,-40C. Approx O.D. (in.) over: Insulation Screen 0.82 0.88 0.86 0.92 0.96 1.02 1.01 1.07 1.10 1.16 1.22 1.28 1.40 1.46 1.54 1.60 Jacket Thickness-mils 80 80 80 80 80 80 80 110 Approx. O.D.-lnches 1.07 1.11 1.21 1.26 1.35 1.47 1.65 1.86 Approx. Net Wt. {lbs/M'} 850 970 1280 1435 1810 2350 3240 4220 PDS 2:16 PDS 2:18 MEDIUM VOLTAGE SINGLE CONDUCTOR POWER CABLES OKOGUARD - 105°C URO-J 15kV, 25kV AND 35kV, Sun Res 100% and 133% INSULATION LEVEL· FULL or 1/3 NEUTRAL Construction: One stranded or solid aluminum or copper conductor, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR insulation screen, and copper concentric neutral wires spaced uniformly around the insulation screen, Okolene jacket with red stripes and ligh1ning bolt. Speclftcatlona: AEIC CS8, ICEA S-94.o49, RUS 7CFR 1728.204, CSA C68.5, ASTM B-231, B-496, Catalog Number Aluminum* Conductor Size 161-23-2060 161-23-2072 2 Strd 1/0 Strd ~ Nominal Diameter Over Insulation (in.) Conductor Temperature: 105°C Continuous, 140°C Emergency. Sizes: #2 AWG - 1000 kcmil Application: Provides circuit reliability in primary underground distribution systems. Cable can be directly buried or installed in underground duct or conduit. Nominal Diameter Over Insulation Shield (in.) Copper(1) Neutral Size Nominal O.D. (in.) Net Weight lbs/1000 ft. Ship Weight (lbs/M') 15kV-175 Mil Wall -100% Insulation Level .66 .75 .73 .83 Full (10X#14) Full (16X#14) 0.97 1.06 517 667 603 725 1.06 1.06 1.08 1.12 1.12 1.15 1.30 1.96 788 577 595 656 726 752 889 2237 855 635 662 736 792 818 1002 2518 1.08 1.15 1.30 1.50 1.73 1.95 2.15 602 752 890 1234 1666 2244 2808 669 820 1005 1425 1853 2468 3093 1.20 803 870 1.23 1.40 1.80 2.08 2.22 832 1011 1784 2450 3024 899 1129 1988 2754 3535 1.44 1061 1179 15kV-220 Mil Wall -133% Insulation Level (2) 141-23-9460 161-23-3057 161-23-3060 161-23-9525 161-23-3069 161-23-3072 160-23-3081 160-23-3096 2 Strd Copper 2Sol 2 Strd 1/0 Sol 1/0 Sol 1/0 Strd 410 Strd 750 Strd .75 .74 .77 .81 .81 .84 .99 1.48 .82 .82 .84 .89 .89 .92 1.06 1.58 Full (16X#14) Full (10X#14) Full (10X#14) Two-Third (10X#14) Full (16X#14) Full (16X#14) One-Third (11X#14) One-Third (15X#10) 15kV-220 Mil Wall -133% Insulation Level-Fiiied Strand 163-23-3060 163-23-3072 162-23-3081 162-23-3090 162-23-3093 162-23-3096 162-23-3099 2 Strd 1/0 Strd 410 Strd 350 Strd 500 Strd 750 Strd 1000 Strei 161-23-4069 1/0 Sol 163-23-4072 162-23-4081 162-23-4093 162-23-4096 162-23-4099 1/0 Strd 410 Strd 500 Strd 750 Strd 1000 Strei 161-23-6072 1/0 Strd .77 .84 .99 1.16 1.29 1.48 1.63 .85 .92 1.06 1.26 1.39 1.58 1.77 Full (10X#14) Full (16X#14) One-Third (11X#14) One-Third (18X#14) One-Third (16X#12) One-Third (15X10) One-Third (18X.1066) 25kV-260 Mil Wall -100% Insulation Level .89 .97 Full (16X#14) 25kV-260 Mil Wall -100% Insulation Level-Filled Strand .92 1.07 1.37 1.56 1.71 1.00 1.17 1.47 1.70 1.85 Full (16X#14) One-Third (11X#14) One-Third (16X#12) One-Third (15X10) One-Third (18X .1066) 35kV-345 Mil Wall -100% Insulation Level 1.10 1.20 Full (16X#14) 35kV-345 Mil Wall -100% Insulation Level-Filled Strand 163-23-6072 1/0 Strd 1.10 1.20 Full (16X#14) 1.44 1063 1181 (1) Individual wire size and count may vary. The resulting combination meets the 1/3rd, 2/3rds or full neutral, size requirement. (2) Catalog Number 141-23-9460 is listed and shipped with UL's MV-90 and CSA rating printed on the jacket. All other cables shown are available with same listing on a special order basis. CSA listing is also available on a special order basis. *Except as noted. NOTE: All cables above are available with MV-105 when an X-Olene (XLPE) jacket is used, on special order basis. 16 BLACK RED MEDIUM VOLTAGE MULTl CONDUCTOR POWER CABLES OKOGUARD SHIELDED C-L-X 15kV ®• Type MV-105 or MC-HL FOR CT USE, Sun Res PDS 2:24 UL and ABS listed as Marine Shipboard Cable Type CLXM-CWCMC 133% INSULATION LEVEL Construction: Three compact stranded copper conductors, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting EPR Insulation screen, phase Identification strips, and copper shield tape with 12.5 % nominal overlap, over individual conductors, with one stranded copper grounding conductor, fillers, and binder tape over the core, corrugated aluminum C-L-X sheath with or without red Okoseal jacket. Conductor Temperature: 105°C Sizes:# 2 AWG - 750 kcmil Application: Economical and versatile alternate to a conduit system; for services, feeders, and branch circuits in electric utility, industrial, and commercial application; power lighting, control and signal circuits; indoors or outdoors, in wet or dry locations, direct burial, in cable tray, in raceways, as open runs of cable, as aerial cable on a messenger, and in Class I, Class II, and Class III, Division 1 & 2 hazardous locations. &p.cllk:dons: MC-HL UL 1569 & 1072 CSA C68.10, ASTM B-496, ICEA 5-93-639 AEIC CS8 Catalog Number 571-23-3504 571-23-3516 571-23-3524 571-23-3536 571-23-3544 571-23-3548 Conductor Size Insulation AWG or kcmll Thickness-mils 2 220 210 220 220 4/0 350 220 500 220 750 220 Insulation O.D. Inches 0.76 0.87 0.97 1.12 1.24 1.41 PDS 2:19 & 2:20 C·L·XO.D. (In.) 2.15 2.40 2.62 2.98 3.28 3.76 Jacket Thickness· mils 60 75 75 75 85 85 Approx. O.D. Inches 2.28 2.56 2.79 3.14 3.51 3.94 Approx. Net wt. (lbs/M') 2420 3434 4460 6264 8269 11317 OKOGUARD-SHIELDED OKOSEAL 5/8kV & 15kV Type MV-105, Sun Res For CT Use @0 SkV 133% & 8kV 100%, and 15kV 133% INSULATION LEVEL UL Listed for use in Cable Trays Construction: Three compact stranded copper conductors, extruded semiconducting EPR strand screen, Okoguard EPR insulation, extruded semiconducting insulation screen, phase identification strips (red, black, blue) and copper shield tape over individual conductors, with 12.5% nominal overlap, with one bare stranded copper grounding conductor, fillers, and binder tape over the core and covered with a black flame retardant PVC jacket (sizes 4/0 and larger, the jacket is our arctic grade PVC). Conductor Temperature: 105°C Sizes: #6 AWG - 500 kcmil Application: For services, feeders, and branch circuits in electric utility, industrial, and commercial application; power lighting, control and signal circuits; indoors or outdoors, in wet or dry locations, direct burial, in cable tray, in raceways, as open runs of cable and as aerial cable on a messenger. llpeclfications: UL 1072, ASTM B-496 ICEA S-93-639 AEIC CS8, CSA C68.10 5/8kV Grounding Conductor SlzeAWG 6 4 3 2 1 1/0 Catalog Number 114-23-3630 114-23-3640 114-23-3648 114-23-3736 114-23-3772 114-23-3782 Conductor Size AWGorkcmil 6 2 2/0 4/0 350 500 Insulation Thickness-mils 115 115 115 115 115 115 Insulation O.D. Inches 0.44 0.54 0.65 0.75 0.89 1.01 Grounding Conductor SizeAWG 6 6 4 3 2 1 Jacket Thickness· mils 80 80 110 110 110 110 Approx. O.D. Inches 1.29 1.51 1.80 2.02 2.33 2.59 115-23-3802 115-23-3806 115-23-3808 115-23-3812 115-23-3814 2 2/0 4/0 350 500 220 220 220 220 220 0.76 0.87 0.97 1.12 1.24 6 4 3 2 1 110 110 110 140 140 2.02 2.26 2.48 2.85 3.10 Approx. Net Wt. (lbs/M') 1015 1560 2513 3455 5116 6799 15kV 18 2280 3260 4285 6168 7895 PDS 5:2 PDS 5:13 PDS 5:29 PDS 5:31 PDS 5:18 PDS 5:19 INSTRUMENTATION CABLES c-L·X OKOSEAL TYPE P-OSISP.OS ® Type rfCIPLTC Cablel300V Rated 105"C PDS lk2 a s:14 For CT Use, Sun Ree cw.., r 11: lnllrwnenllllloll1)119 P-()SandSl4JScablll, 'loitb CIDllllNICIUlly •ldedandCG11U11tltlldaunnsm c-t.~•hMlh, wlhOlloMBl)8cllel. llilldl/WNt9 and n1mt.lnld cdotcoa. llrilm#IB&•18AWG ~ I ''' ' '''' \ \ App!lllllllDll: cm!•-. In.._,., a .. aua n, dl'IGllllN~ 8IWoflld lily•m• . .wh.U181119fvr Dlvllbl 2 ar m. DMalaln 2 llllardou8 loedon1.Al8ob'-anpJMrlmllldl111pdlidl'6'9111VcSllll IFPIJperNEC Cildt '190. Mm UL 13, IEEE 3U and EEE 1202 Wlbl h:Y lame IMlll. AIM>, pmeee 210.ClllO BTU 1191tb11 llylame llllt Pl!l' ICEA T·2H20. .,,.. • *=".Viitaa1.1.za. ..... 584-11HM01 &14-1!5-l401 --of Pan 18(1)() 16(7X) a- I, DMalan 2 ar ', c.i...a For-on PLTCorITCdl'OUW'MUll9plVl.eGUolle991nstphys!Oll d1m1gearllg~1111 lereq&ired; lndoo111orouldOG111,•apen runulcablil, In Single Pa.,. and Tllad Cable8 P.OS Numllw ofTMdll 1 ._, .... ... Tilll 11 15 16 --- 11111•.l.-t Tlllcknel• 11111& C-YCO.D. 35 0.43 0.43 36 ,,.,........ "'·' ... Dilllt....... ~ so Cill Appnm:. Aw- O.D..oln. (1......, 0.54 0.64 Ne!Wt. 134 1Ci6 Multl.flmlr and Tit.I Crbln SP.OS Cdalot Cone...., NumlMr -AWG (l1nllds) Ge1·1o-a3112 &8MH904 Ge1·1o-aaa8 &IMD-9912 Ge1·1o-aaz4 &8MD-CM02 58MD-3l04 &IMIHMOI Ge'l-111-3412 &81-11»424 58M!H404 &SM&-S408 &81·115-3112 16(7X) 18(7X) 16(7X) 1817Xl 16(7X) 18(7X) 18(7X) 18(7X) 18(7X) 18(7X) 111(7X) 18(7X) 18(7X) 22 ,,, Nllllllllr l'ml111 2 ,,, TMd8 4 8 12 24 2 "8 12 24 4 a 12 ... ...... lln8ulallon '1111--- mile 16 15 1G 15 1G 15 1G 15 1G 15 1G 15 1G "°soeo OUCO.D. (ln.) 0.8111 0.112 D.80 lllO 0.92 70 1.:.M. 061 0.71 80 o..as eo 1..oe 1.37 eo 80 70 Cill 50 o..as 70 ..... Appraar. O.D•.fu 0.71 OM 80 so eo OUllr.IBlcll '1111--- D.80 1..Cl2 1.19 50 1.114 1.$5 0.78 lllO 0.82 50 lllO 50 1.114 lllO 1.17 App-. N10llL (li.IM') ..212 273 529 255 327 505 50 llO 50 IA8 0.91 $71 1245 3114 1.13 111111 lllO 1.$11 INSTRUMENTATION CABLES PDS 5l40 a S;G rn,11EE.1-.caz-.m• • :MllUM,1A.1•&1a1CM Single Pair and Triad Calllea P4S ~ llUl!INr 584 1111-3401 &84 B& 3401 .,,.,,. Cond- Nim. llHNllG {Ill••> 111(7X) 18(7X) Number of NM9 1 1 INllllllOll lbl*-· llllMr.lamt TIMI_... 111111 1111111 1514 11114 88 68 C:UC O.D. ('1,1 0,!13 0,63 auw :IAdclll lbl*Ill. . !Ill liO Apsns, O.D.oln, ,84 ,114 Multi-Pair and Triad Cablea SP.os c.lilll'I Cond- Nllftlller llHNllG 5111«1-3402 681-«l-3404 5111-eo-3408 681.al-3412 5111-eo-342A 681.ea-3438 581-es-3404 681.eli-3408 5111-es-3412 111(7X) 18(7X) 111(7X) 111(7X) 111(7X) 18(7X) 111(7X) 111(7X) 111(7X) {Ill••> ....... .,.... ,,...... Nllftlller ,..'*!left el Thlllawl• 2 4 a 12 24 38 4 8 12 mlls 194 1614 194 1614 194 1614 194 16/4 194 llllMr.lamt TIMI 1111111 40 6CI 50 6CI 50 6CI 50 6CI 50 • c.uc O.D. ('!,) DJJ7 D.80 0.118 1.11 1..42 1JJll OJM. 1..00 1.28 auw J9clllll lblollltlttl.. !Ill liO 50 60 50 80 50 60 50 .lpfll"lllL O.D..ln, 0.78 0.81 1.04 1.22 1.!53 1.82 0.915 1.17 1.40 Apprax. Nl&WL llbelll') 182 180 _._, IMIWI. tMll') 2a4 33li 482 874 1118 16811 3115 ISl7 883 SPECIAL PURPOSE CABLES *X-RAY CABLE 65-250 kV D C Construction: Two constructions are standard - one having three conductors and the other four conductors. The conductors are coated stranded copper, over which is an extruded semiconducting layer followed by Okonite insulation, extruded insulation shield, coated copper braid and an Okoseal jacket. Sizes: 3 conductors and 4 conductors Application: To supply the anode and cathode voltages to the X-Ray tube. Also used in other high voltage, low current applications. Specifications: NEMA XR-7 OKOGUARD AERIAL JUMPER CABLE 15kV Conductor Temperature: 90°C Sizes: #2 AWG - #410 AWG Insulation Thickness: 210 mils Application: For use as temporary power leads or "by-pass" jumpers for open aerial lines or aerial disconnects and switches in electric utility applications, for outdoor use only. Catalog Number 303-21-1934 303-21-1938 303-21-1940 303-21-1944 Conductor SlzeAWG 2 1/0 Number of Strands 259 259 259 437 210 410 PDS2:31 Approx. O.D.-ln. 0.78 0.86 0.91 1.06 SOLID TYPE PILC 15kV Paper Insulated Lead Covered Power Cable Construction: 3 compact sector copper conductors, polybutene impregnated paper insulation, copper bearing lead sheath, and Okolene (PE) jacket Conductor Temperature: 90°C Sizes: 350 - 500 kcmil Application: For use in underground ducts, direct buried, and aerially when lashed to a messenger. Okonite PILC cable are manufactured in accordance with and meet the requirements of AEIC CS1-12 12th Edition. Specifications: AEIC CS1-12 Catalog Number 101-63-4544 101-63-4665 Conductor Size kcmil 350 500 Insulation Thickness mils 165 165 Lead Thickness mils 100 105 *Call your Okonite Representative for ordering information from stock. 24 Jacket Thickness mils 90 110 Approx. O.D. -Inches 2.37 2.64 Weight lbs.lft. 8.14 10.37 PDS 7:1 PDS 7:17 PDS 7:11 PDS 7:10 PDS 7:12 PDS 7:11 PDS 7:8 SPLICING AND TERMINATING PRODUCTS C-L-X TERMINATING TOOL KIT AppllMl!ect: lb• C-1.X Teim~ Tod Kit centail'a al lb IDda ,...allld ID remcMl lhe cw11111 )llckll and amlrun lllledl ft'Om Ill• c-i...,x power, canlld, and ...,_"'811on ..... The C*ll Sitma 9llW '"*1 aleol be .._. on l111&1od16danncr1nd IMll 111M1hed ClllHl. II IH'fllilllblll In al!Mran lleclllccr a ,._mlllla The .i...ti!D...,.111...Slil;l•"""'elher•120\/aDar2211V ac. 2500ipm double lnUaled molot. 1bil lghtwelghl pnaumallc motor II """""'41 llr a2.200rpm ~wtlab """'"" 90 Piii GI llrpnNU111 rarirmmum eftlclency. The Sll'llll Cllllle Clulda ir.epa Ille - C8IWed en Ille Clble when ftnt oUl<MI of 1" dlm9llN'w ""9. ...,.L Cerltlntll: 1.aillla Sitma !law, 1-Slrllll CGll Clidl, 12-li" 4111. High !lpaed 8teel ll8w Blldel, 1-1\lblng cutllr, 1.awnel LDdl Plln. 1·10' Rllradllllle Tapa, 1~16'x11"ScNwdlllle•, 1.calllaKNl!t,4'bla, 1.QdWBlaHlldlr, 3-10' HadalawBl.-, 1·Tacl C... 1.f'8dlockwlltl2""8. D9Mllpllon Clll 109 NLllM' Nit Weight (Illa.) Shlppllll Weight (II&) c-a...x Tennlndng Tool Kit "'80&01·1Ga Elaclrlc • 120 Valt iu: 15112 18 "'lllNl-01·1528 Pneumallc: • 80 ptl 15112 18 13112 13112 18 17 112 112 CUI• Sltlllll Saw, Smlll CUI• Gcllde •d 12 Hl9h Speed SWI SawBll.dM "'ll08-01.oo28 "'80&01.c528 Eltlclllc • 120 Volt ac Pneumallc: • 80 ptl "'806-01-6754 12 High Speed Bmel 8.w Bl.'J!' dilln'IMar, 7 IM!h ps ind!, petk.., in a IOlftl tin oonlalner 27 SPLICING AND TERMINATING PRODUCTS Removing the C-L-X Annor Thi• pracdn llpplm ID .. lw- al C.WC armer• lllumlnum, ciopper, brvnm lftd 811H-elleel. Sar. wurldng IQCllCU9 era II> be obMMld, e.~. ~"-and ..n glovM. Praclk:e MN1ons 1118 NCOmn111ded IO llldlallzltall oanoemed ~th• pucedulM and equipment. 1. Remove the jacket lo expose the desired length of m-ermDNd cable ¥1111*1 th• enc:lo9ure. 2. IWer" ID the C-1.·X fttllng n1rucllona fw the lelllllh of C.L·X mmorlll> be eJCP088c1 ~Ille end oflhejacki8tand m&lk th• C.L·X armer Bl the top at the c:rown nearut 1111 lhat poht • For c.L-X Diametets 1 5/ff' and StNlller, Go To Slepl 10 thraugh 12. • Far c.L.X DllllllBlll.. gl'lllller lhan 1 s.ia• Fal- Sll!pa 3 thraugh 8 end 12. 3. Flm Ille C.L-X mnor 'Mii be chumferentlally cut 11111111 • h1lckl!llY blade, (note the C-1.·X saw tool kit 18 aupplled with a hack111v lllad• and blade holder) cut thraugh the crown (high point) Clf the C-1.·X Bl an angle so as to ccmact (or bridge) the valleys ~- pcinta) on bath lides of Iha ctOWll. 4.Againullingahadclawblade, mllrllacinunf..mialllCCl'llin theVllll11p~acent1Dthecutc:cawncannlldlng both ofthe crown c:iut to the valil)'9. Do not cut thraugh armer In ¥8111'19· I. Hold~lhe--rl11kl, flexthecabkl bym~nglhefrM end to u 11> lnlk the 8CCl9 around lhe c:lraimft1111D8 of th• cable. I. Nexttha C-L·Xwill be longitudinally cut bypetforming the following: Noell on Ille C-1.·X Saw - T1HI longlludlnal alt 18 made 'With th• C.L-X aaw, 'IMllch haaan -.uM&ble pceltMI depth atcpthatcan and peltially be sat so the aaw blade cuta thraugh the cuta thniugh lhll ¥81¥. A pups - dllplh ia achilMld 'IMl1111 80 ID 95 % of the melal In the 119lley la l'lll11CllNld. U.."' - . lll809ofthec:alilebe&'lg 18nnhl*dlD8CUUl!th•blad•depth and pnidlce. a.._ Sel l*lde ID nllllOV9 80to9&% atthemelal thlckneH In the valley. -l'lld. 7. With cable UI at the free end of the cable llld llllvane11 lhll Kati aaw, mllldng 81119 ID . - alight ~ ~ure to mei'ltllln Ille depth of c:utelara Ille cable, to Ille q cut. When adYanclng th•-· be 8Ureto mahlaln a llralght 11119 !JV cumng •Iara Ille ._,. point at the cable; thl8 atrac1s the cut dllplh allo. See fclkMIO: 1.--1 If Ii• naca1aary ta stop aitting or if• padian of the all ia llO be repwlal, " " c:.utlon 'IMlen 1dw~11g the blade• kickback may occur. I. N. th• compl9tlon of the lo!Vtudhlll M. 9larllflll at the he end, mm a ~d• blade aavlQMlr Into th• cut and Wat Repeal untlllhel't'Gcutlll l'lllldled. lNllwll -lheNmaln~ iMlal in the VIII• to breakcpllf'land Ille armor k>I- en Ille Ollbla. Do not drive lhll-----intnthe cutiM!h rite bw • 11118 may dmn8ge the underlylng ciondudcnt. •· Sllcle the off the ceble. In the ev9lll that the armer le IW!t 8RUld the cable, pl11111 may be used to grab the armor a:t lhe spa and pul It ft111t ll'cm Ille c:allle. Fer lalve dlametar Ollbles, v.fl-long lenglha of ermorllt81o be ramowict t.o cuts mpaClld 180° apart ar11 nicamnwldad ao thattha armer maybe ren_.i In lwl>pl-. (Go 10"9p12) • for C-1.-X DBll8tln 1 518" and Smaller Fellow SW,,. 10 tl'Rugh 12. 1D. Uelflll a hac:lalaw lllade or lublflll c:utler, clrcunt'8nlntlaly llCCJN lhe c.L-X armor. ~the cable in both hands .tlh lhe llCCl'8 centated be1- hands, 1nd flax the cable at the acara 11119 until t apent. Sllde the eheeth oft' the c:eille. 11. Fore.we cablM wfth ... merJadwt or cable cio1°191111c1b1• where th• C-1...X mmor 18 light fltlq llRllRI the lnuat.ed ccnductors, lhe C.L·X-ehoulcl be Ull8d .ittl lhe Cllllonal red cclcred callle .,de. TNll gulclil 888lalB In can11111tng lhe-Cll'I emaldama!llt'cablil. The pi'OC8du1111and p-.dicnlofateps 3 ID 8 llpply here ••• 12. Ramaw1 the cable 111... and nwlrllr tape and lnatllll the C-l.-XflOIO•Pll"the 11181Wdurer'a lnmdon8. The cable It now 1-'Yto be 18nnhaled Into the encl01Ura. CONDUCTOR COLOR CODING SEQUENCE ICEA S-73-532 TABLE E-2 Color Sequence (No Green or White Conductors) Conductor Base Tracer Number Color Color 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow Black - Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown Special Order: Any or all of the following conductors may be added when specifically requested by the customer to meet his specific application requirements. These conductor codings comply with UL and NEC requirements Purpose Base Color Tracer Color Equipment Grounding Uninsulated Green Green 1 or more continuous yellow stripes Grounded White White White White White White White Black continuous stripe Red continuous stripe Blue continuous stripe Orange continuous stripe Brown continuous stripe Numeric Printing 29 CONDUCTOR COLOR CODING SEQUENCE ICEA S-73-532 TABLE E-1 Color Seauence (INCLUDES GREEN AND WHITE CONDUCTORS) Conductor Base Tracer Number Color Color 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange - Black Black Black Black Black White White White White Red Red Red Red Green Green CONDUCTOR IDENTIFICATION INFORMATION E-1 Color sequences for utility conductor identification, see Appendix E, Table E-1, ICEA Standard S-73-532, includes green and white. E-2 Color sequence for industrial conductor identification, see Appendix E, Table E-2, ICEA Standard S-73-532, excludes green and white. METHOD-1 Conductor identification, colored compounds with tracers in accordance with the ICEA standard. METHOD-2 Conductor identification, neutral compounds with tracers in accordance with the ICEA Standard. METHOD-3 Conductor identification, neutral or single colored compounds with surface printing of numbers and color designations in accordance with the ICEA Standard. METHOD-4 Conductor identification, neutral or single colored compounds with surface printing of numbers in accordance with the ICEA Standard. METHOD-5 Conductor identification, individual color coding with braids in accordance with the ICEA Standard. 30 MISCELLANEOUS INFORMATION Decimal e~uivalents of one incti Table 9-2 8ths 16ths 32nds - - 1 - 1 2 3 4 .015625 .03125 .046875 .0625 - - 5 6 7 8 .078125 .09375 .109375 .125 9 10 11 12 .140625 .15625 .171875 .1875 13 14 15 16 .203125 .21875 .234375 .25 17 18 19 20 .265625 .28125 .296875 .3125 - 1 2 3 - 1 2 4 - - - 2 4 8 - - - - 5 - 3 6 - 7 9 - - 5 10 64ths Useful Identities, Equations and Conversion Factors 1 mil= 0.001" 1 circular mil = (1 mil)2 Area of a circle = II r2 or II 0214 where, II= 3.1416 r =radius D =diameter 1 mm = 39.4 mils 1 mile = 5280 ft 1 km = 0.6214 miles 1 km= 3281 ft 1 mile = 1.609 km 1 inch = 25.4 mm 1 meter= 3.281 ft 1 meter= 39.37 inches 1 ton (US) = 2000 lbs To Convert mils circular mils inches inches feet miles kilometers kilometers pounds pounds pounds/ft tons (US) psi volts/mil ohms/1000ft gigaohms - 1000 ft Multiply by 0.0254 5.07 x 1Q-4 1.0x10 3 25.4 3.048x10 ·4 1.609 0.6214 3.281x10 3 0.4536 4.448 1.488 0.9078 0.00689 0.03937 3.28 305 To Obtain millimeters square millimeters mils millimeters kilometers kilometers miles feet kilograms Newtons Ooules/meter) kilograms/meter tons (metric) megapascals (Mpa) kV/mm ohms/km gigaohms-meter Temperature conversion table Decimal ToC -65. -62.22 -59.45 -56.67 -53.89 -51.11 -48.34 -45.56 -42.78 -40. -37.22 -34.44 -31.67 -28.89 -26.11 -23.33 -20.56 -17.78 -15. -12.22 -9.44 -6.67 -3.89 -1.11 1.67 4.44 7.22 10. 12.78 15.56 18.33 21.11 23.89 26.67 29.44 32.22 35. 37.78 40.56 43.33 46.11 48.89 51.67 54.44 57.22 60. 62.78 65.56 68.33 71.11 73.89 76.67 79.44 82.22 85. 87.78 90.56 93.33 96.11 98.89 101.67 104.44 107.22 110. 112.78 115.56 118.33 121.11 123.89 126.67 129.44 132.22 135. TO CONVERT DEGREES Fore -85 -80 -75 -70 -65 -60 -55 -so -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 Table9-3 ToF -121 -112 -103 -94 -85 -76 -67 -58 -49 -40 -31 -22 -13 -4 5 14 23 32 41 50 59 68 77 86 95 104 113 122 131 140 149 158 167 176 185 194 203 212 221 230 239 248 257 266 275 284 293 302 311 320 329 338 347 356 365 374 383 392 401 410 419 428 437 446 455 464 473 482 491 500 509 518 527 31 NOTES 32 05677 - 3/16 Printed on post consumer paper THE OKONITE COMPANY 102 Hilltop Road, Ramsey, New Jersey 07446 • Phone 201.825.0300 • www.okonite.com