IN STOCK - Okonite

Transcription

IN STOCK - Okonite
Bulletin OSL
OKONITE CABLES
IN STOCK
FOR IMMEDIATE DELIVERY
Portland
Minneapolis
Boston
Hartford
Cumberland
Detroit
Ramsey H.Q.
New York
Paterson
Cleveland Philadelphia
Pittsburgh
Chicago
San Francisco
Salt Lake
Denver
Kansas City
Cincinnati
Washington
Richmond
Santa Maria
Charlotte
Phoenix
Orangeburg Cable
Los Angeles
Birmingham
Atlanta
Orangeburg Compound
Dallas
Manufacturing Plant
Sales Office
Service Center
Houston
New Orleans
Tampa
THE
OKONITE
COMPANY
102 Hilltop Road, Ramsey, New Jersey 07446 • Phone 201.825.0300 • www.okonite.com
NEED CABLE IN A HURRY?
Okonite maintains an in-stock inventory of the products shown in these pages, identified by catalog number. The products
used in this bulletin are stocked in our service centers which are linked via an on-line computer network with our district sales
offices and manufacturing plants to provide up-to-the-minute in-stock and stock replenishment information.
Your local Okonite office and service center, listed below, are ready to assist you with information and to expedite your cable
selection. In addition, they will be able to discuss your needs regarding other sizes and types of instrumentation cables as well
as a full range of power and control cables.
OKONITE DISTRICT SALES OFFICES AND SERVICE CENTERS
Visit us on the internet www.okonite.com
Atlanta District Office
645 Molly Lane
Suite 120
Woodstock, GA 30189
(770) 928-9778
FAX: (770) 928-0913
E-Mail: [email protected]
Denver District Office
636 Coffman Street
Suite 201
Longmont,
80501
(303) 772-3517
FAX: (303) 772-3513
E-Mail: [email protected]
Birmingham District Office
1976 Gadsden Highway
Suite 145
Birmingham, AL 35235
(205) 655-0390
FAX: (205) 655-0393
E-Mail: [email protected]
Boston District Office
169 South River Road
Bedford, NH 0311 o
(603) 625-1900
(781) 749-3374
FAX: (603) 624-2252
E-Mail: [email protected]
Charlotte District Office
11111 Carmel Commons Blvd.
Suite 140
Charlotte, NC 28226
(704) 542-1572
FAX: (704) 541-6183
E-Mail: [email protected]
Hartford District Office
169 South River Road
Bedford, NH 0311 o
(860) 258-1900
FAX: (860) 258-1903
E-Mail: [email protected]
Chicago District Office
2280 White Oak Circle, Suite 106
Aurora, IL 60502
(630) 961-3100
FAX: (630) 961-3273
E-Mail: [email protected]
Cincinnati District Office
11260 Chester Road, Suite 650
Cincinnati, OH 45246
(513) 771-2122
FAX: (513) 771-2126
E-Mail: [email protected]
Cleveland District Office
3926 Clock Pointe Trail, Suite 101
Stow, OH 44224
(330) 926-9181
FAX: (330) 926-9183
E-Mail: [email protected]
Dallas District Office
2220 San Jacinto Blvd.
Suite #125
Denton, TX 76205
(940) 383-1967
FAX: (940) 383-8447
E-Mail: [email protected]
© 2016 The Okonite Company
co
Houston District Office
and Service Center
802 Century Plaza
Houston, TX 77073
(281) 821-5500
FAX: (281) 821-7855
E-Mail: [email protected]
Kansas City District Office
and Service Center
2631 South 96th Street
Edwardsville, KS 66111
(913) 422-6958
FAX: (913) 422-1647
E-Mail: [email protected]
Los Angeles District Office
340 Golden Shore, Suite 400
Long Beach, CA 90802
(562) 590-3070
FAX: (562) 590-3139
E-Mail: [email protected]
Minneapolis District Office
16795 Country Road 24
Suite 110
Plymouth, MN 55447
(763) 432-3818
FAX: (763) 432-3811
E-Mail: [email protected]
New Orleans District Office
and Service Center
101 Delta Drive, Suite J
St. Rose, LA 70087
(504) 467-1920
FAX: (504) 467-1926
E-Mail: [email protected]
New York District Office
Three Garret Mountain Plaza, St. 304
Woodland, NJ 07424
NJ (973) 742-8040 •NY (212) 239-0660
FAX: (973) 742-2156
E-Mail: [email protected]
Philadelphia District Office
501 Cambria Ave., Suite 151
Bensalem, PA 19020
(215) 604-1565
FAX: (856) 604-1564
E-Mail: [email protected]
Phoenix District Office
633 E. Ray Road, Suite 117
Gilbert, Arizona 85296
(480) 838-8596
FAX: (480) 897-8924
E-Mail: [email protected]
Pittsburgh Service Center
120 Solar Drive
Imperial, PA 15126
(724) 899-4300
FAX: (724) 899-4320
E-Mail: [email protected]
Portland District Office
and Service Center
6777 S.W. Bonita Road, Suite 150
Portland, OR 97224
(503) 598-0598
FAX: (503) 620-7447
E-Mail: [email protected]
Salt Lake District Office
5955 S. Redwood Road
Suite 200
Taylorsville, UT 84123
(801) 262-1993
FAX: (801) 262-3167
E-Mail: [email protected]
San Francisco District Office
2440 Camino Ramon, Suite 315
San Ramon, CA 94583
(925) 830-0801
FAX: (925) 830-0954
E-Mail: [email protected]
Tampa District Office
10002 Princess Palm Avenue
Suite 104
Tampa, FL 33619
(813) 627-9400
FAX: (813) 246-4705
E-Mail: [email protected]
Washington District Office
7000 Infantry Ridge Rd., Suite 100A
Manassas, VA 20109
(703) 904-9494
FAX: (703) 904-1610
E-Mail: [email protected]
International Sales
Hilltop Road
P.O. Box 340
Ramsey, NJ 07446
(201) 825-0300
FAX: (201) 825-9026
[email protected]
INDEX
GLOSSARY OF TERMS AND DEFINITIONS ............................................. 5-6
LOW VOLTAGE CABLES TO 2kV
Single Conductor Cables
Okoguard Okolon TS-CPE Type RHH or RHW-2 or USE-2, VW-1 600V RW-90 ...... 7
Okoguard Okolon TS-CPE Type RHH or RHW-2, 2000V .......................................... 7
Multi Conductor Cables
Okonite-FMR Okoseal Type TC-ER 600V/1000V ....................................................... 8
X-Olene - Okoseal Type TC-ER Control Cable (XHHW-2) 600V ................................ 9
C-L-X Type MC & MC-HL for CT USE (XHHW-2) 600V/1000V Control Cable ......... 10
C-L-X Type MC-HL for CT USE (XHHW-2) 600V/1000V .......................................... 11
MEDIUM VOLTAGE POWER CABLES 5kV AND ABOVE
Single Conductor Cables
Okoguard Non-Shielded Okolon TS-CPE FAA L-824 Type B Airport Lighting Cable 12
Okoguard Non-Shielded Okolon TS-CPE Type MV-90 (CT USE) 2.4kV ................. 12
Okoguard Shielded Okoseal Type MV-105 5/8kV ...................................................... 12
Okoguard Shielded Okoseal Type MV-105 {CT USE) 5/8kV ................................... 13
Okoguard Shielded Okoseal Type MV-105 15kV ..................................................... 13
Okoguard Shielded Okolon TS-CPE Type MV-105 (CT USE) 15kV ........................ 14
Okoguard Shielded Okoseal Type MV-105 (CT USE) 15kV .................................... 14
Okoguard Shielded Okoseal Type MV-105 35kV ...................................................... 15
Okoguard Shielded Okoseal 69kV ........................................................................... 15
Okoguard 105°C URO-J 15, 25, 35kV ...................................................................... 16
Multi Conductor Cables
Okoguard Non-Shielded C-L-X Type MV-90 or MC-HL (CT USE) 2.4kV ................. 17
Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 5/8kV ...................... 17
Okoguard Shielded C-L-X Type MV-105 or MC-HL {CT USE) 15kV ....................... 18
Okoguard Shielded Okoseal Type MV-105 (CT USE) 5/8kV & 15kV ......................... 18
INSTRUMENTATION CABLES
Okoseal Type P-OS 300V ........................................................................................ 19
Okoseal Type SP-OS 300V ........................ ............................................ ................. 19
Okoseal-N Type P-OS 600V .................................................................................... 20
Okoseal-N Type SP-OS 600V .................................................................................. 20
Okoseal Type P-OS Thermocouple 300V ................................................................ 21
C-L-X Okoseal Type P-OS Thermocouple 300V ........................................................21
Okoseal Type P-OS/SP-OS C-L-X 300V .................................................................. 22
Okoseal-N Type P-OS/SP-OS C-L-X Type MC or MC-HL 600V/1000V ................... 23
INDEX
SPECIAL PURPOSE CABLES
X-Ray 65-250kV DC .................................................................................................. 24
Okoguard Aerial Jumper Cable 15kV ....................................................................... 24
Solid Type PILC 15kV .............................................................................................. 24
RAILROAD AND TRANSIT SYSTEM CABLES
Signal Cable ............................................................................................................. 25
Type DEL .................................................................................................................. 25
Track Wire ................................................................................................................ 25
Case Wire ................................................................................................................. 25
Tower and Case Wire ............................................................................................... 26
Nylon Braid Case Wire ............................................................................................. 26
Okolon TS-CPE Line Wire ........................................................................................ 26
Okolene Line Wire .................................................................................................... 26
SPLICING AND TERMINATING PRODUCTS
C-L-X Terminating Tool Kit ....................................................................................... 27
Removing the C-L-X Armor ...................................................................................... 28
Color Code Tables ............................................................................................ 29 - 30
Miscellaneous Information ........................................................................................ 31
GLOSSARY
INDUSTRY ASSOCIATIONS
ABS American Bureau of Shipping.
AEIC Association of Edison
Illuminating Companies.
ANSI American National Standards
Institute.
AREMA American Railway Engineering
and Maintenance of Way Association
ASTM American Society for Testing and
Materials.
ICEA Insulated Cable Engineers
Association (former1y IPCEA).
IEC International Electrotechnical Commission
IEEE Institute of Electrical and
Electronics Engineers.
NEC National Electrical Code.
NEMA National Electrical
Manufacturers Association.
NFPA National Fire Protection
Association.
GOVERNMENT AGENCIES
OSHA Occupational Safety and Health
Act administered by U.S. Dept. of
Labor which establishes employee safety
standards in all industrial and commercial
establishments.
RUS Rural Utility Systems of the U.S. Department of Agriculture, former1y REA.
FAA Federal Aviation Administration
EPA Environmental Protection Agency
DOE Department of Energy
FERC Federal Energy Regulatory
Commission
OKONITE REGISTERED TRADE
NAMES
C-L-X® Continuous-Lightweight-Exterior.
Welded and corrugated, impervious
metallic sheathed cables.
LOXARMOR® An inter1ocked "S" shaped
armor cable covering, normally galvanized
steel or aluminum.
OKOBON® A moisture resistant cable
finish consisting of an aluminum/
copolymer tape fused to itself and to an
overall jacket.
OKOBUS Fieldbus instrumentation cable.
OKOCLEAR TP® {TPPO} Thermoplastic
Polyolefin low smoke/zero halogen jacket
compound.
OKOCLEAR TS® Thermosetting Polyolefin low
smoke/zero halogen jacket compound.
OKOGUARD® Okonite's exclusive ethylene-propylene rubber (EPR) based, thermosetting
insulation, with an optimum balance of electrical
and physical properties unequaled in other solid
dielectrics, used on power cables rated 600 V
and above. (43rd Anniversary- 2011)
OKOLENE® Thermoplastic polyethylene or polypropylene based insulation or jacket
compound.
OKONITE® Okonite's exdusive ethylene
propylene rubber (EPR) based, thermosetting insulation used up to 2000V.
OKONITE-FMR® Okonite's exdusive flame and
moisture resistant ethylene propylene rubber
(EPR) insulation used up to 2000V.
OKOGUARD-OKOLON® Composite insulation
system consisting of a layer of EPR and covered
with a chlorinated thermoset compound.
OKO-PACK® Okonite's unique compact round
conductor shape and design.
OKOSEAL® A PVC insulation or jacketing compound with excellent resistance to flame and
most chemicals.
OKOSEAL-N® PVC insulated and nylon
jacketed low voltage conductors, Type THHN,
THWN-2 and TFN.
OKOLON TP-CPE® Thermoplastic moisture resistant CPE compound serving as an outer
jacket.
OKOLON TS-CPE® Thermoset moisture resistant flame retardant CPE outer jacket.
OKOTHERM® Heat resistant silicone rubber
based insulation for use in high temperature locations.
OKOZEL® Okonite's name for its ETFE based
flame and radiation resistant
insulating and jacketing compound.
P-30® Okolene-Okoseal insulated 600V
multiple and single conductor control
cable.
P-45® Okolene-Okoseal Insulated 1000V
Multiple Conductor Control Cable.
X-OLENE® Okonite's name for its XLPE
insulation and jacket.
STANDARD TERMS
AWG American Wire Gauge, based on the circular mil system where 1 mil equals 0.001 inch.
CIC Cable in Conduit for buried distribution systems.
CIC Circuit Integrity flame retardant cables
C-L-X-M C-L-X Marine Shipboard Cable
CPE Chlorinated Polyethylene jacketing
material.
CSA Canadian Standards Association. An
independent organization which implements
and monitors the commercial and consumer
electrical product standards. The CSA assures compliance to the various Canadian
Electrical Code requirements.
CT Designation given to cables meeting UL
requirements for cable tray use.
CTC Designation for Centralized Traffic
Control Code Line cable.
CWCMC UL's designation for 600 volt
C-L-X marine shipboard cable - "continuously welded corrugated MC" cable.
DEL Diesel Electric Locomotive and car
wiring with Okonite insulation and Okolon
jacket.
EPR Ethylene Propylene Rubber insulating
compound ingredient.
ER Exposed Run, UL term designating cables approved for open wire applications.
ETFE Modified Ethylene Tetrofluoroethylene
compound (Okozel) used for insulation and
jackets.
FIELDBUS CABLE - High Speed digital signal transmission instrumentation cable
having specific electrical characteristics.
FPL Power limited Fire Protective Signal
Cable (NEC Art. 760). 300V rated
FMR Flame and Moisture Retardant.
HL Designation given to MC and ITC cables
meeting NEC and UL requirements for use
in Division 1 hazardous locations.
INSULATION LEVEL-100% Cable for use
on grounded systems or where the system is
provided with relay protection such that
grounds faults will be deared as rapidly as
possible but in any case within one minute.
INSULATION LEVEL-133% Cable for use
on ungrounded or grounded systems or
where the faulted section will be de-energized in a time not exceeding one hour.
ITC Instrumentation Tray Cable for instrumentation & control circuits operating ~150V
and~ amps., per NEC Article 727.
kcmil A unit of conductor area in thousands
of circular mils. (Former1y MCM).
LOCA Loss of Coolant Accident, IEEE 383
defines test requirements.
LCS Longitudinal Corrugated Shield.
5
GLOSSARY (continued)
MC Metal-Clad cable. NEC type designa-
tion for power and control cables enclosed
in a welded and corrugated metallic
sheath (C-L-X), or an interlocking tape armor (Loxarmor). (Artide 330)
MC-HL Metal-Clad cable listed for hazardous locations
mil 0.001 inch.
MV Medium Voltage cable. NEC designation for single & multiple conductor
insulated cable rated 2001to35,000 volts.
(NEC Article 328)
NPLF Non-Power Limited Fire Protective
Signal Cable (NEC Art. 760). 600V rated
OKO-MARINE UL designation for non-armored Marine Shipboard Cable.
PLTC Type designation for PowerLimited Tray Cable for use in Class 2 or 3
power-limited circuits; instrumentation,
supervisory control, and thermocouple extension.
P-NS Single pair or triad, Non Shielded,
instrumentation or thermocouple extension
cable.
P-OS Single or multi Pairs or Triads with
Overall Shield, instrumentation or thermocouple extension cable.
POWER-LIMITED CIRCUIT Circuit either
inherently limited requiring no overcurrent
protection or limited by a combination of a
power source and overcurrent
protection.
PVC Polyvinyl Chloride insulating and
jacketing material which is usually flame
retardant and resistant to many
chemicals.
P-104 Okonite's identification number issued by the Pennsylvania Department of
Environmental Resources.
RHH NEC conductor type designation for
conductors with Heat resistant rubber or
XLPE insulation, for use in dry locations.
RHW-2 NEC conductor type designation
for conductors with Heat and Moisture resistant rubber or XLPE insulation, for use
in 90°C wet or dry locations.
RTA Thermoplastic insulated, aluminum
shielded, polyethylene jacketed communication cable.
SCREEN A semiconducting nonmetallic
layer used under and over the insulation of
6
power cables rated over 2kV to reduce
electrical stresses and corona
SEMICONDUCTING An extruded layer or tape
of such resistance that when applied between
two elements of a cable the adjacent surfaces of
the two elements will maintain substantially the
same potential.
SHIELD A nonmagnetic, metallic material applied over an insulated conductor(s) to confine
the electric field to the insulation.
SP-OS Multiple Shielded Pairs or Triads with
Overall Shield, instrumentation or
thermocouple extension cable.
TC NEC type designation for power and
control tray cable. (Artide 336)
TFN NEC conductor type designation for PVC
insulated nylon jacketed conductors in sizes #18
and 16 AWG for use in dry
locations.
THERMOCOUPLE CABLE - A cable consisting
of two dissimilar metals or alloys that, when electrically joined at one end can be used to
measure temperature. These cables have no
voltage rating.
THHN NEC conductor type designation for PVC
insulated nylon jacketed conductors for use in
dry locations.
THWN-2 NEC conductor type designation for
PVC insulated nylon jacketed conductors for use
in 90°C wet or dry locations.
TPPO Thermoplastic Polyolefin, a thermoplastic
jacket material with low smoke characteristics
and is free of halogens.
UL Underwriters Laboratories. An independent
organization which examines, tests, lists and periodically inspects
equipment to appropriate standards.
URO-J Underground Residential distributionOkoguard (EPR) insulation-Okolene Jacket employing a concentric neutral.
USE Underground Service Entrance
cable. (NEC Artide 338)
VERTICAL TRAY FLAME TEST
Conducted per UL, IEEE or ICEA procedures to
demonstrate that a single conductor (1/0 AWG
and larger) or multi-conductor cable will not
propagate a fire in the defined test.
VOLTAGE LEVELS
Power-Limited - 0-300 Volts
Low Voltage - 600-2000 Volts
Medium Voltage - 2400-46000 Volts
High Voltage - >46 to 345kV
VOLTAGE RATING kV, industry convention
to identify voltage levels, phase to phase
voltage.
VW-1 Basic flammability test for single
conductors; employs a tirrill burner applied
intermittently to a Vertical Wire.
XHHW-2 NEC conductor type designation
for conductors with Heat and Moisture resistant thermoset insulation for use in 90°C wet
or dry locations.
XLPE Cross-Linked Polyethylene insulating
compound.
XLPO Cross Linked Polyolefin, a thermoset
jacket material with low smoke characteristics and is free of halogens.
Z NEC conductor type designation for
conductors with ETFE insulation for use in
dry locations.
ZW NEC conductor type designation for
conductors with ETFE insulation for use in
wet or dry locations.
CONDUCTOR IDENTIFICATION
INFORMATION
E-1 Color sequences for utility conductor
identification, see Appendix E, Table E-1,
ICEA Standard S-73-532, includes green
and white.
E-2 Color sequence for industrial conductor
identification, see Appendix E, Table E-2,
ICEA Standard S-73-532, exdudes green
and white.
METHOD-1 Conductor identification, colored
compounds with tracers in accordance with
the ICEA standard.
METHOD-2 Conductor identification, neutral
compounds with tracers in accordance with
the ICEA Standard.
METHOD-3 Conductor identification, neutral
or single colored compounds with surface
printing of numbers and color designations in
accordance with the ICEA Standard.
METHOD-4 Conductor identification, neutral
or single colored compounds with surface
printing of numbers in accordance with the
ICEA Standard.
METHOD-5 Conductor identification, individual color coding with braids in accordance
with the ICEA Standard.
LOW VOLTAGE
SINGLE CONDUCTOR CABLES
PDS 3:1
Specifications: UL44 & 854, ASTM B-8, 8-496,
ICEA lHl5-658, CSA RW90
Catalog
Number
112-24-2071
112-24-2101
112-24-2131
112-24-2191
112-24-2221
112-24-2251
112-24-2311
112-24-2351
112-24-2371
112-24-2411
112-24-2431
112-24-2471
112-24-2531
112-24-2591
112-24-2651
Conductor Size
AWGorkcmil
14
12
10
8
6
4
2
1/0
2/0
4/0
250
350
500
750
1000
OKOGUARD-OKOLON TS-CPE Type RHH or RHW-2 or
USE-2, VW-1 600V RW-90, Sun Res
@0
Construction: One bare stranded round copper conductor, composite
Okoguard EPR-Okolon TS-CPE insulation.Sizes smaller that #8 AWG are
compressed round. #8 AWG and larger are compact round.
Conductor Temperature: 90°C dry, 90°C wet
Sizes: #14 AWG - 1000 kcmil
Appllcatlon: Services. feeders, branch and control circuits for industrial,
commercial and electric utility installations, wet or dry locations, direct burial (#8
AWG and larger) in raceways, underground ducts, or lashed to a messenger for
aerial installation or cable tray (1/0 AWG and larger). Sizes 1/0 AWG and larger
are marked "sunlight resistant, for use in cable tray". Listed by UL as Type
RHH/RHW-2, USE-2, and VW-1. Listed by CSA as RW-90, -40C, FT1 (1/0 and
larger FT4), outdoor. Sizes 1/0 AWG and larger pass UL 1581, and IEEE 1202
Vertical Tray Flame Test Requirements and are marked for "CT-USE", -40°C
installation..
Composite
Approx.
Approx.
Number
Insulation
NetWel ht
of Strands
Thickness-mils
O.D.-lnches
lbs/M'
7
45
0.17
25
45
0.19
34
7
45
7
0.21
49
7
0.27
75
60
119
75
7
0.33
173
75
7
0.38
257
7
75
0.43
414
100
19
0.56
507
100
19
0.60
766
100
19
0.70
938
130
37
0.80
1265
130
37
0.89
1.01
1750
130
37
2590
145
61
1.21
145
61
1.36
3391
OKOGUARD-OKOLON TS-CPE
@0
Type RHH or RHW-2 2000V, Sun Res
PDS3:10
Specillcallons: UL44, ASTM B-8, 8-496,
ICEA S-95-658, CSA RW90
Catalog
Number
113-24-2071
113-24-2101
113-24-2131
113-24-2191
113-24-2221
113-24-2251
113-24-2311
113-24-2351
113-24-2371
113-24-2411
113-24-2431
113-24-2471
113-24-2531
113-24-2591
Conductor Size
AWGorkcmil
14
12
10
8
6
4
2
1/0
210
4/0
250
350
500
750
Construction: One bare stranded round copper conductor, composite
Okoguard EPR-Okolon TS-CPE insulation. Sizes smaller that #8 AWG are
compressed round. #8 AWG and larger are compact round.
Conductor Temperature: 90°C dry, 90°C wet
Sizes: #14 AWG - 750 kcmil
Application: Services, feeders, branch and control circuits for industrial,
commercial and electric utility installations, wet or dry locations, in raceways,
underground ducts, or lashed to a messenger for aerial installation or cable tray
(1/0 AWG and larger). Sizes 1/0 AWG and larger are marked "sunlight resistant,
for use in cable tray". Listed by UL as Type RHH/RHW-2 and VW-1. Listed by
CSA as RW-90, -40C, FT1 (1/0 and larger FT4), outdoor. Sizes 1/0 AWG and
larger pass UL 1581, and IEEE 1202 Vertical Tray Flame Test Requirements and
are marked for "CT-USE" -40°C installation.
Number
of Strands
7
7
7
7
7
7
7
19
19
19
37
37
37
61
Composite
Insulation
Thickness-mils
60
60
60
85
85
85
85
110
110
110
140
140
140
155
Approx.
O.D.-lnches
0.20
0.22
0.24
0.32
0.35
0.40
0.45
0.57
0.61
0.71
0.83
0.92
1.04
1.24
Approx.
NetWei ht
lbs/M'
30
40
55
90
126
180
265
424
517
777
957
1286
1773
2618
7
PDS 4:5
LOW VOLTAGE
MULTl CONDUCTOR CABLES
@ .(~)
X-OLENE - OKOSEAL TYPE TC-ER
CONTROL CABLE (XHHW-2) 600V, Sun Res
PDS4:8
Speclllcatlons: ICEA S-73-532, & ~58.
ASTM B-8, B-496 & UL 1277, C22.2 No. 239
Catalog
Number
202-31-3502
202-31-3503
202-31-3504
202-31-3505
202-31-3507
202-31-3509
202-31-3512
202-31-3602
202-31-3603
202-31-3604
202-31-3605
202-31-3607
202-31-3609
202-31-3612
202-31-3702
202-31-3703
202-31-3704
202-31-3823
202-31-3833
Conductor Size
AWGorkcmil
Strands
14(7x)
14(7x)
14(7x)
14(7x)
14(7x}
14(7x)
14(7x)
12{7x}
12(7x)
12(7x)
12(7x)
12(7x)
12(7x}
12(7x)
10(7x)
10(7x)
10{7x}
12(7x)
10(7x)
Catalog
Number
112-31-3735
112-31-3747
112-31-3759
112-31-3765
112-31-3777
112-31-3781
112-31-3785
112-31-3793
112-31-3797
112-31-3801
Conductor Size
AWGorkcmil
(Strands!
8(7x)
6(7x)
4(7x)
2(7x)
1/0(19x)
2/0(19x)
4/0(19x)
350(37x)
500(37x)
750(61X)
Number of
Conductors
2
3
4
5
7
9
12
2
3
4
5
7
9
12
2
3
4
3
3
Construction: Multiple stranded bare copper conductors, sizes smaller than #8
AWG are compressed, sizes #8 AWG and larger are compact stranded, X-Olene
color coded conductors and Okoseal jacket.
Conductor Temperature: 90°C wet or dry
Sizes: #14 AWG - 750 kcmil
Application: Feeders and branch circuits in industrial, commercial and electric
utility applications; for power, lighting, control, signal, and communication
circuits; indoors or outdoors, in cable trays, between cable trays and utilization
equipment, in raceways, direct burial, supported by a messenger in outdoor
locations, and in cable tray in Class I, Division 2 and Class II, Division 2
hazardous locations in industrial establishments only.UL listed as Type TC,
"Sunliaht Resistant" and for "Direct Burial". cUL listed CIC ~ 410 AWG
Green Insulated Cu
Approx.
Grounding
Approx.
Conductor
Insulation
Jacket
NetWei ht
SizeAWG
Thickness-mils Thickness-mils O.D. - Inches
lbs/M'
45
0.37
78
30
0.39
100
30
45
0.43
122
30
45
144
0.46
45
30
0.50
182
45
30
0.62
254
30
60
0.69
306
30
60
30
45
0.41
98
30
0.43
133
45
30
0.47
164
45
0.51
196
30
45
0.59
269
30
60
0.68
344
30
60
0.77
425
30
60
0.46
132
30
45
0.48
183
45
30
0.56
246
30
60
140
45
1#12
30
0.48
0.55
215
1#10
30
60
POWER CABLE
Number of
Conductors
3
3
3
3
3
3
3
3
3
3
Grounding
Conductor
SlzeAWG
10
8
B
6
6
6
4
3
2
1
Insulation
Jacket
Thickness-mils Thickness-mils
45
60
45
60
45
60
45
80
55
80
55
80
55
80
65
110
65
110
80
110
Approx.
O.D. - Inches
0.66
0.74
0.81
0.97
1.17
1.26
1.47
1.88
2.13
2.56
Approx.
Net Weight
(lbs/M'I
313
440
578
896
1350
1639
2488
4044
5581
8206
* #8 and larger is bare compact round conductor
Conductor Identification:
Sizes #10 AWG & smaller ICEA Method 1, E-2
Sizes #8 AWG & larger ICEA Method 3 Printing of Numbers
(1) Min. Size - UL permits partitioning of Grounding Conductor
(2) Green Insulated Ground
(3) Bare Uninsulated Ground
9
LOW VOLTAGE CONTROL
MULTl CONDUCTOR CABLES
®•
C-L·X 1-yp. MC & Mc-HL FOR CT USE (XHHW·2)
800V Control Cable, Sun Rn
PD8 4(1 .. 4(14
IL & M9 lllllld • llllalln9 9hl..,._. Calli.,.,,._ (Cl X" CWClllC)
IQQl11QGV
ConMnadlon: Two or more ltmlded copper candudol-. llzee #8 AWG and
leotw.,...,mpooclrtnrnded, ~lnsui.tiod,....,r....i9dcandudln,.,wnd
wire (MC.HL ~ llllenl (• nN
7). binder •pe w core, colll.lgBled
.i...,1...,, C.L..X9'*'111, wtilci.....I~-'·
Ceold-Te,......_ llO'Cdry..,Ml • lbr:M:#14AWO ·#IOAWG
AppllcMlon llC • llC-llL:Economcel and wreadle llllefrnl 111 a cancUt
.,am; for ..m-. fwde"" and lnnob d - In ll"llUllMI and aomnenii.1
applcdo..; iio-; llghtlng, ccntml and llgnal chi.lb; lndoora ... ouldoom, In
w.torctylooallon•,dn.itlN!tl, lna.1e1ray, lrn
.., •"l*lnnaf~
•aetlalcallleonan
oir,mld lnClwJ, DMllon2, CluaJJ,DMalon2,and
awmhuenloll• bcalloi•.1)pe MC.HLlll9lndr......1n Clmllll, DMllon 1
. _ ....'*'°""9.
TYPE MC CONTROL CABLE (Da. not lnc:..m praundln1 c:ondud!r)
cm!OI
NumlMi'
llumberftl
Condu2
3
4
Ii
7
Cendudal'llllG(9tranda)
~~
641-31-3002
646-31-311GS
6"-31.aao4
&l&-31-3005
14(7lc)
14(7lc)
1417Xl
14(7lc)
14(7lc)
14(7lc)
14UKI
546-31~
546-31~
546-31-®12
546-31-®18
54N1~
MM1~
548-81~
MM1~
GCe-31~
•
12
19
81
2
US:!
12(7M)
a
4
II
12(hl
12(71c)
12(71c)
12(71c)
12!71Cl
12(71c)
1546-3141187
641-31.aoel
&l&-31-3082
546-31~
N&ll.ron
ThSGb11•mll
30
30
30
30
30
30
30
30
30
30
30
30
30
7
ll
12
18
:'17
2
3
4
30
30
30
30
30
30
30
30
546-31-3117
546-31-3182
546-31-3183
10(7K)
546-31-3184
10(7K)
546-31-3187
1
Color cadre per ICEA melhod I. Table E-2
~~
30
c.uc
JMillll
o.D.AIGllM
1hlolm1M"'9
OM
OM
0.&3
0.&8
0.412
0.71
0.80
60
60
60
50
50
50
0.93
SI
o:r,--
&O
m
1214
0.68
0.!13
0.158
Q.$2
0.58
0.51
0.17
0.75
381
531
9411
15
189
221
2$1
324
'405
O.t9
o:n
o.78
liO
60
&O
50
50
50
50
50
50
0.80
0.88
1.02
1.:17
254
308
1.86
lllO
0.91
1.CO
li03
1.U
1A8
OM
0"8
0.78
721
1301
201
0.88
431
238
281
..... =
TYPE MC-HL CONTROL CABLE (lncludM grounding condudol(•))
c:.taloa
Numwr
6441-31-3403
64U1"'404
ICN1-&IOll
114e41-8408
541-l11-3411
541-l11-3418
64U1-3438
54N1-8453
54N1-3454
541-l11-34Sll
541-l11-3458
GCU1-8481
54N1-8488
54N1-3491
6441-31-3603
C*AWQ
tnuda)
1
1
1
1
1
1
1
llinllm'of
'&it:=
s
4
•
8
11
18
311
3
4
II
8
11
18
311
ICN14llOll
1
1
1
1
1
1
1
1
1
1
54N1-s5Ull
541-l11.a511
~~
8
11
64U1~
10
s
4
•
GftMl~!3..
/11118
3x18a..
3•188'n
#14 Gnlen IR9111nd
#14 Gnen IR911111118d
#14 GNen ll'alllnd
#14 GNen ll'allleliad
#14 Gnlen ll'alllnld
Cond-
ax1aa..
3x18Bare
#12 Giiien ll'alllnld
#12 GNen ll'allleliad
f12 Gnlen IR911"118d
#12 Gnan ll'alllllllld
#12 Gnen ll'allllllld
3x14a..
a.Ha..
#10 Gnlen IR9111nd
#10 Giiien ll'allllllld
#10 Giiien ll'alllnld
~11111111
c~
mis
lncl!M
30
30
30
30
0.63
O.&a
O.IS2
0.11
0.80
0.83
1.24
0.!!8
0.87
0.87
0.80
0.1119
1.02
1.37
0.82
0.117
'1111---
30
30
30
30
30
30
30
30
30
30
30
30
O.D..-
Thlolalmils
liO
60
D.84
D.88
D.73
llO
0.112
0.81
1.04
1.36
0.88
0.71
0.78
0.81
1.00
1.18
1.48
llO
50
50
60
50
50
50
50
llO
llO
!Ill
liO
60
~::f.!I,
141
163
181
210
OM
OM
lllO
SI
lllO
o.61
~
0.80
0.60
0"4
OM
0.73
0.12
0.91
1.04
D.73
D.78
D.811
1.llO
1.118
m;::
lllldl'I
..,
180
222
ll2I
Sil&
664
148
231
288
9311
4211
5111
7lJI
180G!
aoo
S48
.-&1
0:11
llO
30
0.88
50
588
30
0.117
50
704
Cdor Codng per ICEA Melhod 1, Tallie E-2 (fornoft11RM1rdl1! conduclo!a)
30
PDS 4:1 & 4:2
PDS 2:2 & 6:6
PDS 2:4
MEDIUM VOLTAGE
SINGLE CONDUCTOR POWER CABLES
PDS2:3
Specifications: UL 1072. AEIC CS8, ASTM B-496,
CSA C68.3, ICEA S-93-639
Catalog
Conductor Size
AWGorkcmil
Number
114-23-3824
1/0
114-23-3826
2/0
114-23-3832
410
114-23-3834
250
114-23-3838
350
114-23-3846
500
114-23-3873
750
5kV-133% or 8kV-100% INSULATION LEVEL
Construction: One Okopact"' (compact stranded) copper conductor, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting EPR insulation screen, bare copper shielding tape with 25%
minimum over1ap, Okoseal jacket.
Conductor Temperature: 105°C
Sizes: 1/0 AWG - 750 kcmil
Application: Feeders and branch circuits in electric utility, industrial and
commercial applications; may be used in wet or dry locations, in raceways,
messenger supported wiring, and in underground ducts, direct buried (if installed
in a system with a grounding conductor in close proximity) or messenger
supported in industrial and electric utilities. UL listed for cable tray use per NEC
Article 392. Meets UL 1072, IEEE 383, IEEE 1202 & CSA C68.10 FT-4, -40C.
Insulation
Thickness-mils
115
115
115
115
115
115
115
Approx O.D. (in.) over:
Insulation
Screen
0.61
0.67
0.65
0.71
0.75
0.81
0.80
0.86
0.89
0.95
1.01
1.07
1.19
1.25
PDS2:9
OKOGUARD SHIELDED OKOSEAL 15kV
Type MV-105, Sun Res
Speclftcatlons: UL 1072, AEIC CS8, ASTM
~96. ICEA S-93-639
Catalog
Conductor Size
Number
AWGorkcmll
115-23-3111
2
115-23-3115
1/0
115-23-3117
2/0
115-23-3121
4/0
115-23-3123
250
115-23-3127
350
115-23-3131
500
115-23-3135
750
115-23-3139
1000
OKOGUARD SHIELDED OKOSEAL 5/8kV @~
Type MV-105 FOR CT USE, Sun Res and CSA LISTED
Insulation
Thickness-mils
220
220
220
220
220
220
220
220
220
Jacket
Thickness-mils
60
60
80
80
80
80
80
Approx.
O.D.-ln.
0.81
0.85
0.99
1.05
1.14
1.26
1.43
Approx. Net
WT. (lbs/M'}
615
720
1030
1185
1540
2055
2940
®
133% INSULATION LEVEL
Construction: One Okopact"' (compact stranded) copper conductor, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting EPR insulation screen, bare copper shielding tape with 12.5%
nominal over1ap, Okoseal jacket.
Conductor Temperature: 105°C
Sizes: #2 AWG - 1000 kcmil
Application: Feeders and branch circuits in electric utility, industrial and
commercial applications; may be used in wet or dry locations, in raceways,
messenger supported wiring, and in underground ducts, direct burled (if installed
in a system with a grounding conductor in close proximity) or messenger
supported in industrial and electric utilities.
Approx 0.0. (in~ over:
Insulation
creen
0.75
0.81
0.82
0.88
0.86
0.92
0.96
1.02
1.01
1.07
1.10
1.16
1.22
1.28
1.40
1.46
1.54
1.60
Jacket
Thickness-mils
80
80
80
80
80
80
80
80
110
Approx.
O.D.-lnches
1.00
1.07
1.11
1.20
1.26
1.35
1.47
1.64
1.85
Approx. Net
Wl (lbs/M')
670
845
950
1260
1415
1790
2325
3220
4075
13
MEDIUM VOLTAGE
SINGLE CONDUCTOR POWER CABLES
®
PDS 2:11
Specifications: UL 1072, AEIC CS8, ASTM B-496,
CSA C68.3, ICEA S-9~
Catalog
Conductor Size
Number
AWGorkcmil
115-23-2131
500
115-23-2135
750
Insulation
Thickness-mils
220
220
PDS 2:8
Specifications: UL 1072, AEIC CS8, ASTM B-496,
CSA C68.3, ICEA S-9~
Catalog
Conductor Size
Number
AWGorkcmil
115-23-3230
1/0
115-23-3232
210
115-23-3236
4/0
115-23-3238
250
115-23-3240
350
115-23-3242
500
115-23-3243
750
115-23-3244
1000
14
Insulation
Thickness-mils
220
220
220
220
220
220
220
220
OKOGUARD SHIELDED OKOLON TS-CPE 15kV
Type MV-105, Sun Res and FOR CT USE
133% INSULATION LEVEL
Construction: One Okopact® (compact stranded) stranded copper conductor,
extruded semiconducting EPR strand screen, Okoguard EPR insulation,
extruded semiconducting EPR insulation screen, bare copper shielding tape with
25% minimum overlap, Okolon TS-CPE jacket.
Conductor Temperature: 105"C
Sizes: 500-750 kcmll
Application: Feeders and branch circuits in electric utility, industrial and
commercial applications; may be used in wet or dry locations, in raceways, and in
underground ducts.direct buried (if installed in a system with a grounding
conductor in close proximity) or messenger supported in industrial and electric
utilities. UL Listed for cable tray use per NEC Article 392. Meets UL 1072, IEEE
383 and IEEE 1202.
Approx O.D. (in.) over:
$creen
Insulation
1.22
1.28
1.40
1.46
Jacket
Thickness-mils
.080
.080
Approx.
O.D.-lnches
1.49
1.66
Approx. Net
Wt. (lbs/M')
2385
3285
OKOGUARD-SHIELDED OKOSEAL 15kV
Type MV-105 FOR CT USE, Sun Res
133% INSULATION LEVEL
Construction: One Okopact® (compact stranded) copper conductor, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting EPR insulation screen, copper shielding tape with 25% minimum
overlap, Okoseal jacket.
Conductor Temperature: 105"C
Sizes: #1/0AWG-1000 kcmil
Application: Feeders and branch circuits in electric utility, industrial and
commercial applications; may be used in wet or dry locations, in raceways,
messenger supported wiring, and in underground ducts, direct buried (if installed
in a system with a grounding conductor in close proximity) or messenger
supported in industrial and electric utilities. UL listed for cable tray use per NEC
Article392. Meets UL 1072, IEEE383, IEEE 1202and CSAC68.10, FT4,-40C.
Approx O.D. (in.) over:
Insulation
Screen
0.82
0.88
0.86
0.92
0.96
1.02
1.01
1.07
1.10
1.16
1.22
1.28
1.40
1.46
1.54
1.60
Jacket
Thickness-mils
80
80
80
80
80
80
80
110
Approx.
O.D.-lnches
1.07
1.11
1.21
1.26
1.35
1.47
1.65
1.86
Approx. Net
Wt. {lbs/M'}
850
970
1280
1435
1810
2350
3240
4220
PDS 2:16
PDS 2:18
MEDIUM VOLTAGE
SINGLE CONDUCTOR POWER CABLES
OKOGUARD - 105°C
URO-J 15kV, 25kV AND 35kV, Sun Res
100% and 133% INSULATION LEVEL· FULL or 1/3 NEUTRAL
Construction: One stranded or solid aluminum or copper conductor, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting EPR insulation screen, and copper concentric neutral wires spaced
uniformly around the insulation screen, Okolene jacket with red stripes and ligh1ning
bolt.
Speclftcatlona: AEIC CS8, ICEA S-94.o49, RUS 7CFR
1728.204, CSA C68.5, ASTM B-231, B-496,
Catalog
Number
Aluminum*
Conductor
Size
161-23-2060
161-23-2072
2 Strd
1/0 Strd
~
Nominal
Diameter
Over
Insulation
(in.)
Conductor Temperature: 105°C Continuous, 140°C Emergency.
Sizes: #2 AWG - 1000 kcmil
Application: Provides circuit reliability in primary underground distribution
systems. Cable can be directly buried or installed in underground duct or conduit.
Nominal
Diameter
Over
Insulation
Shield
(in.)
Copper(1)
Neutral
Size
Nominal
O.D. (in.)
Net
Weight
lbs/1000 ft.
Ship
Weight
(lbs/M')
15kV-175 Mil Wall -100% Insulation Level
.66
.75
.73
.83
Full (10X#14)
Full (16X#14)
0.97
1.06
517
667
603
725
1.06
1.06
1.08
1.12
1.12
1.15
1.30
1.96
788
577
595
656
726
752
889
2237
855
635
662
736
792
818
1002
2518
1.08
1.15
1.30
1.50
1.73
1.95
2.15
602
752
890
1234
1666
2244
2808
669
820
1005
1425
1853
2468
3093
1.20
803
870
1.23
1.40
1.80
2.08
2.22
832
1011
1784
2450
3024
899
1129
1988
2754
3535
1.44
1061
1179
15kV-220 Mil Wall -133% Insulation Level
(2) 141-23-9460
161-23-3057
161-23-3060
161-23-9525
161-23-3069
161-23-3072
160-23-3081
160-23-3096
2 Strd Copper
2Sol
2 Strd
1/0 Sol
1/0 Sol
1/0 Strd
410 Strd
750 Strd
.75
.74
.77
.81
.81
.84
.99
1.48
.82
.82
.84
.89
.89
.92
1.06
1.58
Full (16X#14)
Full (10X#14)
Full (10X#14)
Two-Third (10X#14)
Full (16X#14)
Full (16X#14)
One-Third (11X#14)
One-Third (15X#10)
15kV-220 Mil Wall -133% Insulation Level-Fiiied Strand
163-23-3060
163-23-3072
162-23-3081
162-23-3090
162-23-3093
162-23-3096
162-23-3099
2 Strd
1/0 Strd
410 Strd
350 Strd
500 Strd
750 Strd
1000 Strei
161-23-4069
1/0 Sol
163-23-4072
162-23-4081
162-23-4093
162-23-4096
162-23-4099
1/0 Strd
410 Strd
500 Strd
750 Strd
1000 Strei
161-23-6072
1/0 Strd
.77
.84
.99
1.16
1.29
1.48
1.63
.85
.92
1.06
1.26
1.39
1.58
1.77
Full (10X#14)
Full (16X#14)
One-Third (11X#14)
One-Third (18X#14)
One-Third (16X#12)
One-Third (15X10)
One-Third (18X.1066)
25kV-260 Mil Wall -100% Insulation Level
.89
.97
Full (16X#14)
25kV-260 Mil Wall -100% Insulation Level-Filled Strand
.92
1.07
1.37
1.56
1.71
1.00
1.17
1.47
1.70
1.85
Full (16X#14)
One-Third (11X#14)
One-Third (16X#12)
One-Third (15X10)
One-Third (18X .1066)
35kV-345 Mil Wall -100% Insulation Level
1.10
1.20
Full (16X#14)
35kV-345 Mil Wall -100% Insulation Level-Filled Strand
163-23-6072
1/0 Strd
1.10
1.20
Full (16X#14)
1.44
1063
1181
(1) Individual wire size and count may vary. The resulting combination meets the 1/3rd, 2/3rds or full neutral, size requirement.
(2) Catalog Number 141-23-9460 is listed and shipped with UL's MV-90 and CSA rating printed on the jacket. All other cables shown are available
with same listing on a special order basis. CSA listing is also available on a special order basis.
*Except as noted.
NOTE: All cables above are available with MV-105 when an X-Olene (XLPE) jacket is used, on special order basis.
16
BLACK
RED
MEDIUM VOLTAGE
MULTl CONDUCTOR
POWER CABLES
OKOGUARD SHIELDED C-L-X 15kV ®•
Type MV-105 or MC-HL FOR CT USE, Sun Res
PDS 2:24
UL and ABS listed as Marine Shipboard Cable Type CLXM-CWCMC
133% INSULATION LEVEL
Construction: Three compact stranded copper conductors, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting EPR Insulation screen, phase Identification strips, and copper
shield tape with 12.5 % nominal overlap, over individual conductors, with one
stranded copper grounding conductor, fillers, and binder tape over the core,
corrugated aluminum C-L-X sheath with or without red Okoseal jacket.
Conductor Temperature: 105°C
Sizes:# 2 AWG - 750 kcmil
Application: Economical and versatile alternate to a conduit system; for
services, feeders, and branch circuits in electric utility, industrial, and commercial
application; power lighting, control and signal circuits; indoors or outdoors, in wet
or dry locations, direct burial, in cable tray, in raceways, as open runs of cable, as
aerial cable on a messenger, and in Class I, Class II, and Class III, Division 1 & 2
hazardous locations.
&p.cllk:dons: MC-HL UL 1569 & 1072 CSA C68.10,
ASTM B-496, ICEA 5-93-639 AEIC CS8
Catalog
Number
571-23-3504
571-23-3516
571-23-3524
571-23-3536
571-23-3544
571-23-3548
Conductor Size Insulation
AWG or kcmll Thickness-mils
2
220
210
220
220
4/0
350
220
500
220
750
220
Insulation
O.D.
Inches
0.76
0.87
0.97
1.12
1.24
1.41
PDS 2:19 & 2:20
C·L·XO.D.
(In.)
2.15
2.40
2.62
2.98
3.28
3.76
Jacket
Thickness·
mils
60
75
75
75
85
85
Approx.
O.D.
Inches
2.28
2.56
2.79
3.14
3.51
3.94
Approx.
Net wt.
(lbs/M')
2420
3434
4460
6264
8269
11317
OKOGUARD-SHIELDED OKOSEAL 5/8kV & 15kV
Type MV-105, Sun Res For CT Use
@0
SkV 133% & 8kV 100%, and 15kV 133% INSULATION LEVEL
UL Listed for use in Cable Trays
Construction: Three compact stranded copper conductors, extruded
semiconducting EPR strand screen, Okoguard EPR insulation, extruded
semiconducting insulation screen, phase identification strips (red, black, blue)
and copper shield tape over individual conductors, with 12.5% nominal overlap,
with one bare stranded copper grounding conductor, fillers, and binder tape over
the core and covered with a black flame retardant PVC jacket (sizes 4/0 and
larger, the jacket is our arctic grade PVC).
Conductor Temperature: 105°C
Sizes: #6 AWG - 500 kcmil
Application: For services, feeders, and branch circuits in electric utility,
industrial, and commercial application; power lighting, control and signal circuits;
indoors or outdoors, in wet or dry locations, direct burial, in cable tray, in
raceways, as open runs of cable and as aerial cable on a messenger.
llpeclfications: UL 1072, ASTM B-496
ICEA S-93-639 AEIC CS8, CSA C68.10
5/8kV
Grounding
Conductor
SlzeAWG
6
4
3
2
1
1/0
Catalog
Number
114-23-3630
114-23-3640
114-23-3648
114-23-3736
114-23-3772
114-23-3782
Conductor Size
AWGorkcmil
6
2
2/0
4/0
350
500
Insulation
Thickness-mils
115
115
115
115
115
115
Insulation
O.D.
Inches
0.44
0.54
0.65
0.75
0.89
1.01
Grounding
Conductor
SizeAWG
6
6
4
3
2
1
Jacket
Thickness·
mils
80
80
110
110
110
110
Approx.
O.D.
Inches
1.29
1.51
1.80
2.02
2.33
2.59
115-23-3802
115-23-3806
115-23-3808
115-23-3812
115-23-3814
2
2/0
4/0
350
500
220
220
220
220
220
0.76
0.87
0.97
1.12
1.24
6
4
3
2
1
110
110
110
140
140
2.02
2.26
2.48
2.85
3.10
Approx.
Net Wt.
(lbs/M')
1015
1560
2513
3455
5116
6799
15kV
18
2280
3260
4285
6168
7895
PDS 5:2
PDS 5:13
PDS 5:29
PDS 5:31
PDS 5:18
PDS 5:19
INSTRUMENTATION
CABLES
c-L·X OKOSEAL TYPE P-OSISP.OS ®
Type rfCIPLTC Cablel300V Rated 105"C
PDS lk2 a s:14
For CT Use, Sun Ree
cw.., r 11: lnllrwnenllllloll1)119 P-()SandSl4JScablll, 'loitb CIDllllNICIUlly
•ldedandCG11U11tltlldaunnsm c-t.~•hMlh, wlhOlloMBl)8cllel. llilldl/WNt9
and n1mt.lnld cdotcoa.
llrilm#IB&•18AWG
~
I
''' ' ''''
\ \
App!lllllllDll:
cm!•-.
In.._,.,
a ..
aua n,
dl'IGllllN~ 8IWoflld lily•m•
. .wh.U181119fvr
Dlvllbl 2 ar
m. DMalaln 2 llllardou8
loedon1.Al8ob'-anpJMrlmllldl111pdlidl'6'9111VcSllll IFPIJperNEC
Cildt '190. Mm UL 13, IEEE 3U and EEE 1202 Wlbl h:Y lame IMlll. AIM>,
pmeee 210.ClllO BTU 1191tb11 llylame llllt Pl!l' ICEA T·2H20.
.,,.. • *=".Viitaa1.1.za.
.....
584-11HM01
&14-1!5-l401
--of Pan
18(1)()
16(7X)
a-
I, DMalan 2 ar
',
c.i...a
For-on PLTCorITCdl'OUW'MUll9plVl.eGUolle991nstphys!Oll
d1m1gearllg~1111 lereq&ired; lndoo111orouldOG111,•apen runulcablil, In
Single Pa.,. and Tllad Cable8 P.OS
Numllw
ofTMdll
1
._, ....
...
Tilll 11
15
16
---
11111•.l.-t
Tlllcknel•
11111&
C-YCO.D.
35
0.43
0.43
36
,,.,........
"'·'
...
Dilllt.......
~
so
Cill
Appnm:.
Aw-
O.D..oln.
(1......,
0.54
0.64
Ne!Wt.
134
1Ci6
Multl.flmlr and Tit.I Crbln SP.OS
Cdalot
Cone....,
NumlMr
-AWG
(l1nllds)
Ge1·1o-a3112
&8MH904
Ge1·1o-aaa8
&IMD-9912
Ge1·1o-aaz4
&8MD-CM02
58MD-3l04
&IMIHMOI
Ge'l-111-3412
&81-11»424
58M!H404
&SM&-S408
&81·115-3112
16(7X)
18(7X)
16(7X)
1817Xl
16(7X)
18(7X)
18(7X)
18(7X)
18(7X)
18(7X)
111(7X)
18(7X)
18(7X)
22
,,,
Nllllllllr
l'ml111
2
,,,
TMd8
4
8
12
24
2
"8
12
24
4
a
12
... ......
lln8ulallon
'1111---
mile
16
15
1G
15
1G
15
1G
15
1G
15
1G
15
1G
"°soeo
OUCO.D.
(ln.)
0.8111
0.112
D.80
lllO
0.92
70
1.:.M.
061
0.71
80
o..as
eo
1..oe
1.37
eo
80
70
Cill
50
o..as
70
.....
Appraar.
O.D•.fu
0.71
OM
80
so
eo
OUllr.IBlcll
'1111---
D.80
1..Cl2
1.19
50
1.114
1.$5
0.78
lllO
0.82
50
lllO
50
1.114
lllO
1.17
App-.
N10llL
(li.IM')
..212
273
529
255
327
505
50
llO
50
IA8
0.91
$71
1245
3114
1.13
111111
lllO
1.$11
INSTRUMENTATION
CABLES
PDS 5l40 a S;G
rn,11EE.1-.caz-.m• •
:MllUM,1A.1•&1a1CM
Single Pair and Triad Calllea P4S
~
llUl!INr
584 1111-3401
&84 B& 3401
.,,.,,.
Cond- Nim.
llHNllG
{Ill••>
111(7X)
18(7X)
Number
of
NM9
1
1
INllllllOll
lbl*-·
llllMr.lamt
TIMI_...
111111
1111111
1514
11114
88
68
C:UC
O.D.
('1,1
0,!13
0,63
auw :IAdclll
lbl*Ill. .
!Ill
liO
Apsns,
O.D.oln,
,84
,114
Multi-Pair and Triad Cablea SP.os
c.lilll'I
Cond-
Nllftlller
llHNllG
5111«1-3402
681-«l-3404
5111-eo-3408
681.al-3412
5111-eo-342A
681.ea-3438
581-es-3404
681.eli-3408
5111-es-3412
111(7X)
18(7X)
111(7X)
111(7X)
111(7X)
18(7X)
111(7X)
111(7X)
111(7X)
{Ill••>
.......
.,.... ,,......
Nllftlller
,..'*!left
el
Thlllawl•
2
4
a
12
24
38
4
8
12
mlls
194
1614
194
1614
194
1614
194
16/4
194
llllMr.lamt
TIMI
1111111
40
6CI
50
6CI
50
6CI
50
6CI
50
•
c.uc
O.D.
('!,)
DJJ7
D.80
0.118
1.11
1..42
1JJll
OJM.
1..00
1.28
auw J9clllll
lblollltlttl..
!Ill
liO
50
60
50
80
50
60
50
.lpfll"lllL
O.D..ln,
0.78
0.81
1.04
1.22
1.!53
1.82
0.915
1.17
1.40
Apprax.
Nl&WL
llbelll')
182
180
_._,
IMIWI.
tMll')
2a4
33li
482
874
1118
16811
3115
ISl7
883
SPECIAL PURPOSE
CABLES
*X-RAY CABLE 65-250 kV D C
Construction: Two constructions are standard - one having three conductors
and the other four conductors. The conductors are coated stranded copper, over
which is an extruded semiconducting layer followed by Okonite insulation,
extruded insulation shield, coated copper braid and an Okoseal jacket.
Sizes: 3 conductors and 4 conductors
Application: To supply the anode and cathode voltages to the X-Ray tube. Also
used in other high voltage, low current applications.
Specifications: NEMA XR-7
OKOGUARD AERIAL JUMPER CABLE 15kV
Conductor Temperature: 90°C
Sizes: #2 AWG - #410 AWG
Insulation Thickness: 210 mils
Application: For use as temporary power leads or "by-pass" jumpers for open
aerial lines or aerial disconnects and switches in electric utility applications, for
outdoor use only.
Catalog
Number
303-21-1934
303-21-1938
303-21-1940
303-21-1944
Conductor
SlzeAWG
2
1/0
Number
of Strands
259
259
259
437
210
410
PDS2:31
Approx.
O.D.-ln.
0.78
0.86
0.91
1.06
SOLID TYPE PILC
15kV Paper Insulated Lead Covered Power Cable
Construction: 3 compact sector copper conductors, polybutene impregnated
paper insulation, copper bearing lead sheath, and Okolene (PE) jacket
Conductor Temperature: 90°C
Sizes: 350 - 500 kcmil
Application: For use in underground ducts, direct buried, and aerially when
lashed to a messenger. Okonite PILC cable are manufactured in accordance with
and meet the requirements of AEIC CS1-12 12th Edition.
Specifications: AEIC CS1-12
Catalog
Number
101-63-4544
101-63-4665
Conductor
Size kcmil
350
500
Insulation
Thickness mils
165
165
Lead
Thickness mils
100
105
*Call your Okonite Representative for ordering information from stock.
24
Jacket
Thickness mils
90
110
Approx.
O.D. -Inches
2.37
2.64
Weight
lbs.lft.
8.14
10.37
PDS 7:1
PDS 7:17
PDS 7:11
PDS 7:10
PDS 7:12
PDS 7:11
PDS 7:8
SPLICING AND
TERMINATING PRODUCTS
C-L-X TERMINATING TOOL KIT
AppllMl!ect: lb• C-1.X Teim~ Tod Kit centail'a al lb IDda ,...allld ID
remcMl lhe cw11111 )llckll and amlrun lllledl ft'Om Ill• c-i...,x power, canlld,
and ...,_"'811on ..... The C*ll Sitma 9llW '"*1 aleol be .._. on
l111&1od16danncr1nd IMll 111M1hed ClllHl. II IH'fllilllblll In al!Mran lleclllccr
a ,._mlllla
The .i...ti!D...,.111...Slil;l•"""'elher•120\/aDar2211V
ac. 2500ipm double lnUaled molot. 1bil lghtwelghl pnaumallc motor II
"""""'41 llr a2.200rpm ~wtlab """'"" 90 Piii GI llrpnNU111 rarirmmum
eftlclency. The Sll'llll Cllllle Clulda ir.epa Ille - C8IWed en Ille Clble when
ftnt oUl<MI of 1" dlm9llN'w ""9.
...,.L
Cerltlntll: 1.aillla Sitma !law, 1-Slrllll CGll Clidl, 12-li" 4111. High !lpaed
8teel ll8w Blldel, 1-1\lblng cutllr, 1.awnel LDdl Plln. 1·10' Rllradllllle
Tapa, 1~16'x11"ScNwdlllle•, 1.calllaKNl!t,4'bla, 1.QdWBlaHlldlr,
3-10' HadalawBl.-, 1·Tacl C... 1.f'8dlockwlltl2""8.
D9Mllpllon
Clll 109 NLllM'
Nit Weight (Illa.)
Shlppllll Weight (II&)
c-a...x Tennlndng Tool Kit
"'80&01·1Ga
Elaclrlc • 120 Valt iu:
15112
18
"'lllNl-01·1528
Pneumallc: • 80 ptl
15112
18
13112
13112
18
17
112
112
CUI• Sltlllll Saw, Smlll CUI• Gcllde
•d 12 Hl9h Speed SWI SawBll.dM
"'ll08-01.oo28
"'80&01.c528
Eltlclllc • 120 Volt ac
Pneumallc: • 80 ptl
"'806-01-6754
12 High Speed Bmel 8.w Bl.'J!' dilln'IMar, 7 IM!h ps ind!, petk.., in a
IOlftl tin oonlalner
27
SPLICING AND
TERMINATING PRODUCTS
Removing the C-L-X Annor
Thi• pracdn llpplm ID .. lw- al C.WC armer• lllumlnum,
ciopper, brvnm lftd 811H-elleel. Sar. wurldng IQCllCU9 era
II> be obMMld, e.~. ~"-and ..n glovM. Praclk:e
MN1ons 1118 NCOmn111ded IO llldlallzltall oanoemed ~th•
pucedulM and equipment.
1. Remove the jacket lo expose the desired length of
m-ermDNd cable ¥1111*1 th• enc:lo9ure.
2. IWer" ID the C-1.·X fttllng n1rucllona fw the lelllllh of C.L·X
mmorlll> be eJCP088c1 ~Ille end oflhejacki8tand m&lk th•
C.L·X armer Bl the top at the c:rown nearut 1111 lhat poht
• For c.L-X Diametets 1 5/ff' and StNlller, Go To Slepl 10
thraugh 12.
• Far c.L.X DllllllBlll.. gl'lllller lhan 1 s.ia• Fal- Sll!pa 3
thraugh 8 end 12.
3. Flm Ille C.L-X mnor 'Mii be chumferentlally cut 11111111 •
h1lckl!llY blade, (note the C-1.·X saw tool kit 18 aupplled with a
hack111v lllad• and blade holder) cut thraugh the crown (high
point) Clf the C-1.·X Bl an angle so as to ccmact (or bridge) the
valleys ~- pcinta) on bath lides of Iha ctOWll.
4.Againullingahadclawblade, mllrllacinunf..mialllCCl'llin
theVllll11p~acent1Dthecutc:cawncannlldlng both
ofthe
crown c:iut to the valil)'9. Do not cut thraugh armer In ¥8111'19·
I. Hold~lhe--rl11kl, flexthecabkl bym~nglhefrM
end to u 11> lnlk the 8CCl9 around lhe c:lraimft1111D8 of th•
cable.
I. Nexttha C-L·Xwill be longitudinally cut bypetforming the
following:
Noell on Ille C-1.·X Saw - T1HI longlludlnal alt 18 made 'With th•
C.L-X aaw, 'IMllch haaan -.uM&ble pceltMI depth atcpthatcan
and peltially
be sat so the aaw blade cuta thraugh the cuta thniugh lhll ¥81¥. A pups - dllplh ia achilMld 'IMl1111
80 ID 95 % of the melal In the 119lley la l'lll11CllNld. U.."' - .
lll809ofthec:alilebe&'lg 18nnhl*dlD8CUUl!th•blad•depth and
pnidlce.
a.._
Sel l*lde ID nllllOV9
80to9&% atthemelal
thlckneH In the
valley.
-l'lld.
7. With cable
UI at the free end of the cable llld
llllvane11 lhll Kati aaw, mllldng 81119 ID . - alight ~
~ure to mei'ltllln Ille depth of c:utelara Ille cable, to Ille q
cut. When adYanclng th•-· be 8Ureto mahlaln a llralght 11119
!JV cumng •Iara Ille ._,. point at the cable; thl8 atrac1s the cut
dllplh allo. See fclkMIO:
1.--1
If Ii• naca1aary ta stop aitting or if• padian of the all ia llO be
repwlal, " " c:.utlon 'IMlen 1dw~11g the blade• kickback
may occur.
I. N. th• compl9tlon of the lo!Vtudhlll M. 9larllflll at the he
end, mm a ~d• blade aavlQMlr Into th• cut and Wat
Repeal untlllhel't'Gcutlll l'lllldled. lNllwll -lheNmaln~
iMlal in the VIII• to breakcpllf'land Ille armor k>I- en Ille
Ollbla. Do not drive lhll-----intnthe cutiM!h
rite
bw • 11118 may dmn8ge the underlylng ciondudcnt.
•· Sllcle the off the ceble. In the ev9lll that the armer le
IW!t 8RUld the cable, pl11111 may be used to grab the armor a:t
lhe spa and pul It ft111t ll'cm Ille c:allle. Fer lalve dlametar
Ollbles, v.fl-long lenglha of ermorllt81o be ramowict t.o cuts
mpaClld 180° apart ar11 nicamnwldad ao thattha armer maybe
ren_.i In lwl>pl-. (Go 10"9p12)
• for C-1.-X DBll8tln 1 518" and Smaller Fellow SW,,. 10
tl'Rugh 12.
1D. Uelflll a hac:lalaw lllade or lublflll c:utler, clrcunt'8nlntlaly
llCCJN lhe c.L-X armor. ~the cable in both hands .tlh lhe
llCCl'8 centated be1- hands, 1nd flax the cable at the acara
11119 until t apent. Sllde the eheeth oft' the c:eille.
11. Fore.we cablM wfth ... merJadwt or cable cio1°191111c1b1•
where th• C-1...X mmor 18 light fltlq llRllRI the lnuat.ed
ccnductors, lhe C.L·X-ehoulcl be Ull8d .ittl lhe Cllllonal red
cclcred callle .,de. TNll gulclil 888lalB In can11111tng lhe-Cll'I
emaldama!llt'cablil. The pi'OC8du1111and p-.dicnlofateps
3 ID 8 llpply here •••
12. Ramaw1 the cable 111... and nwlrllr tape and lnatllll the
C-l.-XflOIO•Pll"the 11181Wdurer'a lnmdon8. The cable It
now 1-'Yto be 18nnhaled Into the encl01Ura.
CONDUCTOR
COLOR CODING SEQUENCE
ICEA S-73-532 TABLE E-2
Color Sequence (No Green or White Conductors)
Conductor
Base
Tracer
Number
Color
Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Black
Red
Blue
Orange
Yellow
Brown
Red
Blue
Orange
Yellow
Brown
Black
Blue
Orange
Yellow
Brown
Black
Red
Orange
Yellow
Brown
Black
Red
Blue
Yellow
Brown
Black
Red
Blue
Orange
Brown
Black
Red
Blue
Orange
Yellow
Black
-
Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Orange
Yellow
Yellow
Yellow
Yellow
Yellow
Brown
Brown
Brown
Brown
Brown
Special Order: Any or all of the following conductors may be added when
specifically requested by the customer to meet his specific application
requirements. These conductor codings comply with UL and NEC requirements
Purpose
Base Color
Tracer Color
Equipment Grounding
Uninsulated
Green
Green
1 or more continuous yellow stripes
Grounded
White
White
White
White
White
White
White
Black continuous stripe
Red continuous stripe
Blue continuous stripe
Orange continuous stripe
Brown continuous stripe
Numeric Printing
29
CONDUCTOR
COLOR CODING SEQUENCE
ICEA S-73-532 TABLE E-1
Color Seauence (INCLUDES GREEN AND WHITE CONDUCTORS)
Conductor
Base
Tracer
Number
Color
Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Black
White
Red
Green
Orange
Blue
White
Red
Green
Orange
Blue
Black
Red
Green
Blue
Black
White
Orange
Blue
Red
Orange
-
Black
Black
Black
Black
Black
White
White
White
White
Red
Red
Red
Red
Green
Green
CONDUCTOR IDENTIFICATION INFORMATION
E-1 Color sequences for utility conductor identification, see
Appendix E, Table E-1, ICEA Standard S-73-532, includes green
and white.
E-2 Color sequence for industrial conductor identification, see
Appendix E, Table E-2, ICEA Standard S-73-532, excludes green
and white.
METHOD-1 Conductor identification, colored compounds with
tracers in accordance with the ICEA standard.
METHOD-2 Conductor identification, neutral compounds with
tracers in accordance with the ICEA Standard.
METHOD-3 Conductor identification, neutral or single colored
compounds with surface printing of numbers and color
designations in accordance with the ICEA Standard.
METHOD-4 Conductor identification, neutral or single colored
compounds with surface printing of numbers in accordance with
the ICEA Standard.
METHOD-5 Conductor identification, individual color coding with
braids in accordance with the ICEA Standard.
30
MISCELLANEOUS
INFORMATION
Decimal e~uivalents
of one incti
Table 9-2
8ths
16ths
32nds
-
-
1
-
1
2
3
4
.015625
.03125
.046875
.0625
-
-
5
6
7
8
.078125
.09375
.109375
.125
9
10
11
12
.140625
.15625
.171875
.1875
13
14
15
16
.203125
.21875
.234375
.25
17
18
19
20
.265625
.28125
.296875
.3125
-
1
2
3
-
1
2
4
-
-
-
2
4
8
-
-
-
-
5
-
3
6
-
7
9
-
-
5
10
64ths
Useful Identities, Equations and
Conversion Factors
1 mil= 0.001"
1 circular mil = (1 mil)2
Area of a circle = II r2 or II 0214
where,
II= 3.1416
r =radius
D =diameter
1 mm = 39.4 mils
1 mile = 5280 ft
1 km = 0.6214 miles
1 km= 3281 ft
1 mile = 1.609 km
1 inch = 25.4 mm
1 meter= 3.281 ft
1 meter= 39.37 inches
1 ton (US) = 2000 lbs
To Convert
mils
circular mils
inches
inches
feet
miles
kilometers
kilometers
pounds
pounds
pounds/ft
tons (US)
psi
volts/mil
ohms/1000ft
gigaohms - 1000 ft
Multiply by
0.0254
5.07 x 1Q-4
1.0x10 3
25.4
3.048x10 ·4
1.609
0.6214
3.281x10 3
0.4536
4.448
1.488
0.9078
0.00689
0.03937
3.28
305
To Obtain
millimeters
square millimeters
mils
millimeters
kilometers
kilometers
miles
feet
kilograms
Newtons Ooules/meter)
kilograms/meter
tons (metric)
megapascals (Mpa)
kV/mm
ohms/km
gigaohms-meter
Temperature
conversion table
Decimal
ToC
-65.
-62.22
-59.45
-56.67
-53.89
-51.11
-48.34
-45.56
-42.78
-40.
-37.22
-34.44
-31.67
-28.89
-26.11
-23.33
-20.56
-17.78
-15.
-12.22
-9.44
-6.67
-3.89
-1.11
1.67
4.44
7.22
10.
12.78
15.56
18.33
21.11
23.89
26.67
29.44
32.22
35.
37.78
40.56
43.33
46.11
48.89
51.67
54.44
57.22
60.
62.78
65.56
68.33
71.11
73.89
76.67
79.44
82.22
85.
87.78
90.56
93.33
96.11
98.89
101.67
104.44
107.22
110.
112.78
115.56
118.33
121.11
123.89
126.67
129.44
132.22
135.
TO CONVERT DEGREES
Fore
-85
-80
-75
-70
-65
-60
-55
-so
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
Table9-3
ToF
-121
-112
-103
-94
-85
-76
-67
-58
-49
-40
-31
-22
-13
-4
5
14
23
32
41
50
59
68
77
86
95
104
113
122
131
140
149
158
167
176
185
194
203
212
221
230
239
248
257
266
275
284
293
302
311
320
329
338
347
356
365
374
383
392
401
410
419
428
437
446
455
464
473
482
491
500
509
518
527
31
NOTES
32
05677 - 3/16
Printed on post consumer paper
THE
OKONITE
COMPANY
102 Hilltop Road, Ramsey, New Jersey 07446 • Phone 201.825.0300 • www.okonite.com