2014 product catalogue

Transcription

2014 product catalogue
UPS.AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER.AVR
2014 PRODUCT CATALOGUE
WHY CENTRAION?
Centralion Industrial Inc. (“Centralion”)
was founded in 1979 and has become a
leading
developer
of
power
quality
solutions since 1989. With more than 30
years of experiences in the industry,
Centralion’s power products have served all
over the world as a key component in
power
systems
which
required
uninterrupted power supply, and Centralion
has won its reputation as a trustful and
reliable partner for its customers.
INDEX
 Online UPS
INNOVA
INNOVA+
INNOVA+ Z
INNOVA COMBO
INNOVA RT
INNOVA HD
JAGA
ONL - 01
ONL - 05
ONL - 07
ONL- 09
 Standby UPS
 AC Inverter
APFC OFFICE
MAX OFFICE Z
MAX POWER
DC UPS
HYBRID
INVEREX
INVEREX S
INVEREX Z
INVEREX HD
STB - 01
STB - 03
STB - 05
STB - 07
ONL - 11
ACI - 01
ACI - 03
ACI - 05
ACI - 07
ACI - 09
HOSTA
VANDA
IBERIS
AVR - 01
AVR - 03
AVR - 05
 Accessory
ONL - 15
NMC CARD
ACC - 01
ONL - 17
AS400 CARD
ACC - 01
 Modular UPS
 Line-interactive UPS
SPRING MT
SPRING MTZ
SPRING RT
AURORA
AURORA VISTA
UNI
UNI Z
BLAZER VISTA
 AVR
GRIPOWER PRO
 Solar Charger Controller
MDL - 01
SOLAR MATE
SCC - 01
LIN - 01
LIN - 03
LIN - 05
LIN - 09
LIN - 11
 3-Phase UPS
APUS
APUS Z
 Solar Inverter
3PH - 01
3PH - 03
LIN - 13
LIN - 15
LIN - 17
GRID-TIED SINGLE-PHASE
SUNVILLE
SLI - 01
GRID-TIED THREE-PHASE
SUNVILLE
SLI - 03
CMC CARD
ACC - 01
MINI NMC CARD
ACC - 02
MINI AS400 CARD ACC - 02
MINI CMC CARD
ACC - 02
RELAY CARD
ACC - 03
USB/RS232CARD
ACC - 03
Environmental Monitoring
Probe (EMP)
ACC - 03
EXTERNAL CHARGER ACC - 04
Automatic Transfer Switch
(ATS)
ACC - 04
COMPATIBILITY MATRIX
ACC - 05
Product series marked with “Z” are designed for 100-120V system.
Product specification and outlook are subject to change without prior notice.
Online UPS
INNOVA series
KEY FEATURES
• True double-conversion design with high adaptability to harsh mains
conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
2K / 3K
• Automatic boost/buck voltage regulation (± 2%)
• Supports energy-saving ECO mode
• Intelligent communication slot enables remote monitoring
• LCD display shows easy-to-understand operational status
1K
TYPICAL APPLICATION
ONL - 01
Online UPS
SPECIFICATION
MODEL
INNOVA TOWER 1K
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
INNOVA TOWER 1KS
INNOVA TOWER 2K
1000VA/800W
2000VA/1600W
110 ~ 300 VAC
45 Hz– 55 Hz/54 Hz – 66 Hz
Single Phase with Ground
<5% @ full load
0.8
2001/2082/220/230/240VAC
±2 %
50 / 60 ± 0.2Hz
3:1
< 3% @ linear load, < 5%@ non-linear load
Pure Sine Wave
N/A
88%
85%
93%
94%
12V / 7Ah
N/A
12V / 7Ah
3
N/A
8
36V
96V
> 5min
N/A
> 9min
5 hour
N/A
5 hour
1A
8A
1A
0ms
4ms
<10ms
LCD
Yes
145 X 220 X 400 mm
192 X 347 X 460 mm
13 kg
7 kg
31 kg
13 kg
0~45 °C
50dB @1 meter
Yes
Yes
Yes
Note:
1. 200VAC will be subject to 80% output derating
2. 208VAC will be subject to 90% output derating
ONL - 02
INNOVA TOWER 2KS
INNOVA TOWER 3K
INNOVA TOWER 3KS
3000VA/2400W
N/A
N/A
N/A
N/A
8A or 12A (optional)
31 kg
12V / 7Ah
8
96V
> 5min
5 hour
1A
N/A
N/A
N/A
N/A
8A or 12A (optional)
13 kg
Online UPS
INNOVA series
KEY FEATURES
• True double-conversion design with high adaptability to harsh mains
conditions
• DSP design enables precise and reliable control
• High output power factor (0.9)
• High efficiency results in energy saving
• Automatic boost/buck voltage regulation (±1%)
• Supports energy-saving ECO mode
• Intelligent communication slot enables remote monitoring
6K / 10K
• LCD display shows easy-to-understand operational status
• Supports up to 4-unit parallel operation
TYPICAL APPLICATION
ONL - 03
Online UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ full load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
INNOVA 6K
INNOVA 6KS
6000VA/5400W
110~276VAC
45-55Hz / 54-66Hz
Single phase with ground
<5% @ full R load
0.9
2081/220/230/240VAC
±1%
50/60 ± 0.05 Hz
3:1
<2% @ Linear Load, <5% @ Non-Linear Load
Pure Sine Wave
Up to 4 units
>92%
>92%
>96%
12V/7Ah
N/A
20
N/A
240VDC
> 5min
N/A
5 hour
N/A
1.4A
4A
0ms
0ms
10ms
LCD
Yes
260 x 708 x 550 mm
88 kg
25.5 kg
0-45° C
≤50dB @ 1 Meter
RS23: optional, USB: standard
Yes
Yes
Note:
1. 208VAC will be subject to 90% output derating
ONL - 04
INNOVA 10K
10000VA/9000W
INNOVA 10KS
12V/9Ah
20
N/A
N/A
> 4 min
5 hour
1.4A
N/A
N/A
4A
84 kg
29.5 kg
Online UPS
INNOVA+
KEY FEATURES
series
• True double-conversion design with high adaptability to harsh mains
conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
2K / 3K
• Output power factor (0.9)
• Automatic boost/buck voltage regulation (± 2%)
• Supports energy-saving ECO mode
• Intelligent communication slot enables remote monitoring
1K
TYPICAL APPLICATION
ONL - 05
Online UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (PF0.8 , full load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
USB
External Slot
Emergency Power Off
INNOVA+ 1K
INNOVA+ 1KS
1000VA/900W
110 ~ 300 Vac
45~55 Hz/54~66 Hz
Single Phase with Ground
<5% with full load
0.9
2001/2082/220/230/240VAC
±2 %
50/60Hz ±0.2 Hz
3:1
<3% @ linear load, <5% @non-linear load
Pure Sine Wave
N/A
87%
85%
93%
12V / 7Ah
N/A
3
N/A
36V
36V
5 min
N/A
5 hours
N/A
1A
8A
0ms
<4ms
<10ms
LCD
Yes
145 X 220 X 400 mm
13 kg
7 kg
0~45 °C
<50dB @1 meter
Yes
Yes
Yes
Note:
1. 200VAC will be subject to 80% output derating
2. 208VAC will be subject to 90% output derating
LIN - 06
INNOVA+ 2K
2000VA/1800W
INNOVA+ 2KS
INNOVA+ 3K
3000VA/2700W
INNOVA+ 3KS
N/A
N/A
96V
N/A
N/A
8A or 12A(optional)
12V / 7Ah
8
96V
5 min
5 hours
1A
N/A
N/A
96V
N/A
N/A
8A or 12A(optional)
31 kg
13 kg
88%
94%
12V / 7Ah
8
96V
9 min
5 hours
1A
192 X 347 X 460 mm
31 kg
13 kg
Online UPS
INNOVA+ Z series
KEY FEATURES
• High-frequency design and full-digital DSP control provide optimal
performance
• High output power factor (0.9)
2K / 3K
• Wide input voltage range (55~150Vac)
• Precise output voltage regulation ( 1%)
• Graphic LCD display
• Intelligent communication slot enables remote monitoring
• Supports ECO mode and power segments
• cTÜ Vus certified
1K
TYPICAL APPLICATION
ONL - 07
Online UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
INNOVA+ Z 1K
INNOVA+ Z 2K
1000VA/900W
2000VA/1800W
55~150VAC
46-54Hz / 56-64Hz
Single Phase with Ground
<15% with full R load
<10% with full R load
0.9
1001/1102/115/120VAC/127VAC
±1%
50/60Hz ±0.1 Hz
3:1
<4% @ linear load ; <8% @ non-linear load
Pure Sine Wave
N/A
89.0 %
90.0%
86.0%
85.9%
96.0%
96.0%
12V/7.2Ah
12V/7.2Ah
3
6
36V
96V
>5 min
>5 min
5 hours
1A
0ms
<4ms
<10ms
LCD
Yes
145 X 220 X 345 mm
190 X 318 X 383 mm
12.5 kg
25 kg
0~40 °C
<45dB @ 1 meter
Yes
Yes
Yes
Note:
1. 100VAC will be subject to 90% output derating for 1K and 3K models, and 80% output derating for 2K model
2. 110VAC will be subject to 90% output derating for 2K model
ONL - 08
INNOVA+ Z 3K
3000VA/2700W
<15% with full R load
88.9%
84.8%
96.0%
12V/9Ah
6
96V
>4 min
27.1 kg
Online UPS
INNOVA COMBO series
KEY FEATURES
• True double-conversion design to deal with harsh mains conditions
• High output power factor (0.9)
• Precise output voltage regulation ( 1%)
• Wide AC input voltage range (110-276VAC)
• LCD display shows easy-to-understand operational status
• Supports energy-saving ECO mode
• Two Intelligent communication slots and one RS232 port enable up to 3
channels remote monitoring
10K / 20K
• Supports parallel connection for up to 4 units
TYPICAL APPLICATION
ONL - 09
Online UPS
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
INNOVA COMBO 10K
INNOVA COMBO 20K
10000 VA/ 9000W
20000VA/18000W
110VAC-276VAC (Single Phase Input)
190VAC-478VAC (Three Phase Input)
45Hz ~ 55Hz / 54Hz ~ 66Hz
Single Phase with Ground (L-N-G) /Three Phase with Ground (R-S-T-N-G)
< 5% @ full R load
0.9
2001/208/220/230/240VAC
±1%
50/60 ± 0.05 Hz
3:1
<2% @ Linear Load, <5% @ Non-Linear Load
Pure Sine Wave
Up to 4 units
>93%
>93%
>97%
12V/9Ah
24x1
24x2
288VDC
288 VDC
>5 minutes
3 hours
5 hours
2A
4A
0ms
0ms
<10ms
LCD
Yes
350 x 890 x 650
115 kg
183 kg
0-45° C
<55dB @ 1 Meter
Yes
Yes
Yes
Note:
1. 200VAC will be subject to 90% output derating
ONL - 10
Online UPS
INNOVA RT series
KEY FEATURES
• True double-conversion design with high adaptability to harsh mains
conditions
• Ideal to for high-end equipment which are sensitive to power quality
• Supports energy-saving ECO mode
• Wide input range (120-176VAC)
1K / 1.5K / 2K / 3K
• Intelligent communication slot enables remote monitoring
• Precise output voltage regulation (1%)
• Rack/tower dual set-up with rotatable LCD panel
TYPICAL APPLICATION
ONL - 11
Online UPS
SPECIFICATION
MODEL
INNOVA RT 1K
CAPACITY
1000VA/900W
1500VA/1350W
120~176VAC
45~55Hz/54~66Hz
Single Phase with ground
<5% @ full load
0.9
208/220/230/240VAC
± 1%
50/60 ± 0.2 Hz
3:1
<2% @ Linear Load, <5% @ Non-Linear Load
Pure Sine Wave
N/A
88%
89%
83%
84%
95%
12V/7Ah
N/A
12V/7Ah
N/A
3
N/A
4
N/A
36VDC
48VDC
> 5min
N/A
> 5min
N/A
3 hour
N/A
3 hour
N/A
1.5A
6A
1.5A
6A
0 ms
4 ms
<10 ms
LCD
Yes
438 x 86.5 x 435 mm
16.2 kg
8.4 kg
19.7 kg
9.3 kg
0-40° C
<45dB @ 1 Meter
<50dB @ 1 Meter
Yes
Yes
Yes
Input Voltage Range
Frequency Range
INPUT
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
OUTPUT
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
EFFICIENCY
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
BATTERY
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current (max)
Battery Mode ↔ Inverter Mode
TRANSFER TIME Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
RS232/USB
INTERFACE
External Slot
Emergency Power Off
INNOVA RT 1KS INNOVA RT 1.5K INNOVA RT 1.5KS
ONL - 12
INNOVA RT 2K INNOVA RT 2KS
INNOVA RT 3K
2000VA/1800W
3000VA/2700W
INNOVA RT 3KS
92%
88%
12V/9Ah
4
48VDC
> 5min
3 hour
1.5A
N/A
N/A
19.7 kg
9.3kg
N/A
N/A
6A
12V/9Ah
6
72VDC
> 5min
3 hour
1.5A
N/A
N/A
N/A
N/A
6A
438 X 86.5X 604 mm
27.8 kg
13 kg
Online UPS
INNOVA RT series
KEY FEATURES
• True double-conversion design with high adaptability to harsh mains
conditions
• Ideal to for high-end equipment which are sensitive to power quality
• Supports energy-saving ECO mode
• Wide input range (120-276VAC)
6K
• Intelligent communication slot enables remote monitoring
• Precise output voltage regulation (1%)
• Independent input for bypass operation
10K
TYPICAL APPLICATION
ONL - 13
Online UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Battery Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
INNOVA RT 6K
INNOVA RT 6KS
6000VA/5400W
120~276VAC
45-55Hz / 54-66Hz
Single phase with ground
<5% @ full load
0.9
208/220/230/240VAC
± 1%
50/60 ± 0.1 Hz
3:1
<2% @ Linear Load, <5% @Non-Linear Load
Pure Sine Wave
N/A
92%
89%
96%
12V/5Ah
N/A
15
N/A
180VDC
>2.5mins
N/A
3 hours
N/A
1A
8A
0 ms
0 ms
<10 ms
LCD
Yes
438 x 129x 698 mm
438 x 129x 640 mm
46kg
19 kg
0-40° C
<55dB @ 1 Meter
Yes
Yes
Yes
ONL - 14
INNOVA RT 10K
10000VA/9000W
INNOVA RT 10KS
93%
90%
97%
12V/9Ah
20
240VDC
> 3.5mins
3 hours
1.7A
N/A
N/A
8A
438 x 215.5x 704 mm
82.5kg
438 x 215.5x 640 mm
26kg
N/A
N/A
Online UPS
INNOVA HD series
KEY FEATURES
• True double-conversion design with high adaptability to harsh mains
conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
• Output power factor 0.9
1K / 2K / 3K
• Precise voltage regulation (± 2 %)
• Intelligent communication slot enables remote monitoring
• Standard rack design for installation in cabinet
TYPICAL APPLICATION
ONL - 15
Online UPS
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
Frequency Range
INPUT
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
OUTPUT
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
EFFICIENCY
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
BATTERY
Rated Battery Voltage
Backup Time (@ full load)
Recharge Time (to 90%)
Battery Mode ↔ Inverter Mode
TRANSFER TIME Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Inverter Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
RS232/USB
INTERFACE
External Slot
Emergency Power Off
Note:
1. 100VAC will be subject to 80% output derating
2. 110VAC will be subject to 90% output derating
INNOVA HD 1K
INNOVA HD 2K
1000VA/900W
2000VA/1600W
80~144VAC
90~138VAC
50/60Hz
Single phase with ground
<8%
0.9
1001/1102/120/127VAC
2%
50/60Hz  0.1 Hz
3:1
< 3 % @ linear load, < 5 % @ non-linear load
Pure sine wave
N/A
87%
88%
82%
84%
93%
12V/9Ah
3
6
36V
72V
6 min
6 min
3 hours
0 ms
4 ms
10 ms
LCD
Yes
438 x 86.5 x 445 mm
438 x 86.5 x 610 mm
16 kg
29 kg
0 ~ 40 °C
<50 dBA
Yes
Yes
Yes
ONL - 16
INNOVA HD 3K
3000VA/2700W
90%
3 min
29 kg
Online UPS
JAGA series
KEY FEATURES
2K / 3K
• True double-conversion design with high adaptability to harsh mains
conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
• Output power factor 0.8 (up to 0.9 under 30℃)
• Wide AC input range (110-300VAC)
• Automatic switching between 50/60Hz system
• Precise voltage regulation (± 1 %)
• Supports AC generator
• Supports DC start-up and auto restart
• Intelligent communication slot enables remote monitoring
1K
TYPICAL APPLICATION
ONL - 17
Online UPS
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
Frequency Range
INPUT
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
OUTPUT
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
EFFICIENCY
Battery Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
BATTERY
Backup Time (@ Full Load)
Recharge Time (to 90%)
Charging Current (max)
Battery Mode ↔ Inverter Mode
TRANSFER TIME
Inverter Mode ↔ Bypass Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
RS232
INTERFACE
External Slot
Emergency Power Off
Note:
1. 200VAC will be subject to 80% output derating
2. 208VAC will be subject to 80% output derating
JAGA 1K
JAGA 2K
1000VA/800W
2000VA/1600W
110~300VAC
40-70Hz
Single phase with ground
<10%
0.8
2001/2082/220/230/240VAC
±2%
50/60 ± 0.05 Hz
2.95:1
< 4% @ linear load, < 7% @ non-linear load
Pure sine wave
N/A
>89%
>90%
>83%
>83%
N/A
12V/45W
2
4
24VDC
48VDC
4.5 min
4.5 min
7 hours
7 hours
1A
1A
0ms
4ms
LCD
Yes
144 x 229 x 345 mm
190 x 328 x 393 mm
9.2 kg
17.2 kg
0 ~ 40 °C
<45dB
<50dB
Yes
Yes
No
ONL - 18
JAGA 3K
3000VA/2400W
>83%
6
72VDC
4.5 min
7 hours
1A
22.6 kg
Line-interactive UPS
SPRING MT series
KEY FEATURES
1000 / 1500
• High performance supported by sinewave output and built-in voltage
regulator
• Compact foot print fits easily into small spaces such as kiosks, cash machines
and ticket machines
• HID Power Device-compliant USB interface enables integration with built-in
power management and auto shutdown features of Windows and Mac OS
and Linux
• High conversion efficiency (>95%) results in energy saving
• LCD graphic display gives comprehensive information at a glance
• Easy battery replacement
TYPICAL APPLICATION
500 / 750
LIN - 01
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
SPRING MT 750
750VA/450W
SPRING MT 1000
1000VA/700W
SPRING MT 1500
1500VA/900W
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
SPRING MT 500
500VA/350W
176-288VAC
45-55 Hz / 55-65 Hz
Single phase with ground
0.7
220/230/240VAC
-10% ~ +6%
-10% ~ +6%
50/60 Hz ±0.1 Hz
Pure sine wave
N/A
> 94%
> 90%
> 70%
12V/7Ah
1
12VDC
0.6
0.7
0.6
12V/9Ah
1
12V/7Ah
2
24VDC
12V/9Ah
2
Backup Time (@ Typical PC load)
17 min
20 min
35 min
40 min
6.8 kg
150x209x340 mm
10.8 kg
11.5 kg
Recharge Time (to 90%)
TRANSFER TIME Battery Mode ↔ Line Mode
DISPLAY
3 hours
<10ms
LCD
AUDIBLE ALARM
Yes
DIMENSION
NET WEIGHT
WxHxD
Operating Temperature
ENVIRONMENT
Noise Level
INTERFACE
USB
150x209X240 mm
6.4 kg
0~40° C
<40dBA @ 1 meter
Yes
<45 dBA@1 meter
LIN - 02
Line-interactive UPS
SPRING MTZ series
KEY FEATURES
1000 / 1500
• Designed for 110/120VAC AC grid system
• High performance supported by sinewave output and built-in voltage
regulator
• Compact foot print fits easily into small spaces such as kiosks, cash machines
and ticket machines
• HID Power Device-compliant USB interface enables integration with built-in
power management and auto shutdown features of Windows and Mac OS
and Linux
• High conversion efficiency (>95%) results in energy saving
• LCD graphic display gives comprehensive information at a glance
• Easy battery replacement
TYPICAL APPLICATION
500 / 750
LIN - 03
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
SPRING MTZ 750
750VA/450W
SPRING MTZ 1000
1000VA/700W
SPRING MTZ 1500
1440VA/900W
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
SPRING MTZ 500
500VA/350W
88-144VAC
45-55 Hz / 55-65 Hz
Single phase with ground
0.7
100/110/120VAC
-10% ~ +6%
-10% ~ +6%
50/60 Hz ±0.1 Hz
Pure sine wave
N/A
> 94%
> 90%
> 70%
12V/7Ah
1
12VDC
0.6
0.7
0.625
12V/9Ah
1
12V/7Ah
2
24VDC
12V/9Ah
2
Backup Time (@ Typical PC load)
17 min
20 min
35 min
40 min
6.8 kg
150x209x340 mm
10.8 kg
11.5 kg
Recharge Time (to 90%)
TRANSFER TIME Battery Mode ↔ Line Mode
DISPLAY
3 hours
<10ms
LCD
AUDIBLE ALARM
Yes
DIMENSION
NET WEIGHT
WxHxD
Operating Temperature
ENVIRONMENT
Noise Level
INTERFACE
USB
150x209X240 mm
6.4 kg
0~40° C
<40dBA @ 1 meter
Yes
<45 dBA@1 meter
LIN - 04
Line-interactive UPS
SPRING RT series
KEY FEATURES
• High output power factor (0.9)
• Built-in voltage regulator stables unstable AC input power
• Intelligent communication slot enables remote monitoring
• HID Power Device-compliant USB interface enables integration with builtin power management and auto shutdown features of Windows and Mac
OS and Linux
1K / 1.5K
• Rack/tower dual set-up with rotatable LCD panel
• Optional EBM (Extended Battery Module) available for battery expansion
TYPICAL APPLICATION
LIN - 05
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ full load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
RS232/USB
INTERFACE
External Slot
Dry Contact
SPRING RT 1K
SPRING RT 1KS
1000VA/900W
154~288VAC
45-55Hz / 55-65 Hz
Single phase with ground
10%
0.9
220/230/240VAC
-10% ~ +6%
±5%
50/60 Hz ± 0.1 Hz
< 3% @ linear load, < 6% @ non-linear load
Pure sine wave
N/A
97%
Boost mode: 92%, Buck mode: 95%
>82%
12V/7Ah
N/A
3
N/A
36VDC
4.5 min
N/A
3 hours
N/A
1.5A
7A
2-6 ms
LCD
Yes
438 X 86.5 x 435 mm
16kg
10kg
0~40°C
<45dB
Yes
Yes
Yes
LIN - 06
SPRING RT 1KE
SPRING RT 1.5K
1500VA/1350W
SPRING RT 1.5KS
< 10% @ linear load
< 3% @ linear load, < 6% @ non-linear load
>80%
12V/9Ah
2
24VDC
3min
8 hours
1.1A
>82%
12V/9Ah
3
36VDC
3 min
4 hours
1.5A
13kg
17.9kg
N/A
N/A
Yes
Yes
N/A
N/A
N/A
N/A
7A
10kg
Line-interactive UPS
SPRING RT series
KEY FEATURES
• High output power factor (0.9)
• Built-in voltage regulator stables unstable AC input power
• Intelligent communication slot enables remote monitoring
• HID Power Device-compliant USB interface enables integration with builtin power management and auto shutdown features of Windows and Mac
OS and Linux
2K / 3K
• Rack/tower dual set-up with rotatable LCD panel
• Optional EBM (Extended Battery Module) available for battery expansion
TYPICAL APPLICATION
LIN - 07
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ full load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
WxHxD
Operating Temperature
Noise Level
RS232/USB
External Slot
Dry Contact
SPRING RT 2K
SPRING RT 2KS
2000VA/1800W
154~288 VAC
45-55Hz / 55-65 Hz
Single phase with ground
10%
0.9
220/230/240VAC
-10% ~ +6%
±5%
50/60 Hz ± 0.1 Hz
< 3% @ linear load, < 6% @ non-linear load
Pure sine wave
N/A
97%
Boost mode: 92%, Buck mode: 95%
80%
12V/7Ah
N/A
6
N/A
72VDC
4.5 min
N/A
3 hours
N/A
1.5A
7A
2-6 ms
LCD
Yes
438 X 86.5 x 604 mm
28kg
16kg
0~40°C
<45dB
Yes
Yes
Yes
LIN - 08
SPRING RT 2KE
SPRING RT 3K
3000VA/2700W
SPRING RT 3KS
12V/9Ah
4
48VDC
3 min
4 hours
1.5A
12V/9Ah
6
72VDC
3 min
4 hours
1.5A
N/A
N/A
438 X 86.5 x 436 mm
21kg
438 X 86.5 x 604 mm
31kg
N/A
N/A
7A
16kg
Line-interactive UPS
AURORA series
KEY FEATURES
• Entry-level backup solution with excellent performance
• Build-in voltage regulator for reliable power quality
• DC start function enables UPS to be started up without AC power
• Green Power Function for energy saving
1200 / 2200
• Auto restart while AC recovery
• AC Overloading protection
• Surge protection for phone / modem line
• CE compliant
450 / 650 / 850
TYPICAL APPLICATION
LIN - 09
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
ARURORA 450
AURORA 650
450VA/240W
650VA/360W
Input Voltage Range
162-290VAC
Frequency Range
45~55Hz/55~65Hz
Input Wiring
Single phase with ground
Output Power Factor
0.55
Nominal Output Voltage
110/120/220/230/240 Vac
±15%
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode) ±10%
Frequency Range ( Battery Mode )
50/60Hz  1Hz
Output Waveform
Modified sine wave
Parallel Operation
N/A
Line Mode
95%
AVR Mode
88%
Battery Mode
60%
Battery Type
12V/4.5Ah
12V/7Ah
Number of Internal Battery
1
1
Rated Battery Voltage
12VDC
12VDC
Backup Time (@ Typical PC load)
8 min
16 min
Recharge Time (to 90%)
6 hours
Charging Current
1A
Battery Mode ↔ Line Mode
2-6 ms
LED
YES
WxHxD
100 x 143 x 300
3.5kg
4.5kg
Operating Temperature
0~40°C
Noise Level
<40dB
LIN - 10
AURORA 850
850VA/480W
AURORA 1200
1200VA/600W
AURORA 2200
2200VA/1100W
0.5
12V/9Ah
1
12VDC
20 min
12V/7Ah
2
24VDC
40 min
12V/9Ah
2
24VDC
50 min
4-8 ms
5.0kg
139 X 195 x 364
8.8kg
10.3kg
<45dB
Line-interactive UPS
AURORA VISTA series
KEY FEATURES
• Entry-level backup solution with excellent performance
• Build-in voltage regulator for reliable power quality
• DC cold start function
1200 / 2200
• Auto restart while AC recovery
• Front panel USB interface for easy installation(650/850)
• Easy-to-understand graphic LCD display
• AC Overloading protection
• Surge protection for phone / modem line
• CE compliant
650 / 850
TYPICAL APPLICATION
LIN - 11
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
AURORA VISTA 650
650VA/360W
162~290VAC
45~55/55~65 Hz
Single phase with ground
0.55
220/230/240 VAC
±15%
Voltage Regulation (Battery Mode)
±10%
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
EFFICIENCY
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
BATTERY
Backup Time (@ Typical PC load)
Recharge Time (to 90%)
Charging Current
TRANSFER TIME Battery Mode ↔ Line Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
USB
INTERFACE
External Slot
TVSS protection
50/60Hz  1 Hz
Modified sine wave
N/A
95%
88%
60%
12V/7Ah
1
12VDC
16 min
6 hours
1A
2-6 ms
LCD
Yes
100 x 143x 290
2.36 kg
0~40°C
<40dB
Yes
No
RJ11 Jack
AURORA VISTA 850
850VA/480W
AURORA VISTA 1200
1200VA/600W
AURORA VISTA 2200
2200VA/1200W
0.56
0.5
0.55
12V/9Ah
1
12VDC
20 min
12V/ 7Ah
2
24VDC
30 min
12V/9Ah
2
24VDC
50 min
4-8 ms
2.7 kg
139 x 195 x 364
5.3 kg
5.93kg
<45dB
RJ45 Jack
LIN - 12
Line-interactive UPS
UNI
KEY FEATURES
series
•
Ideal backup power solution for home and office
•
Optimized design leads to cost-saving and space-saving
•
Boost and buck circuit to deal with challenging power conditions
•
Compact size which can be easily fit with PC-related equipment
•
Top access of outlet makes power core connection easier
600
TYPICAL APPLICATION
LIN - 13
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
UNI 600
600VA/360W
150~290VAC
47~53/57~63 Hz
Single phase with ground
0.6
230VAC
N/A
Voltage Regulation (Battery Mode)
±10%
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ 120W load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
50 1 Hz
Modified sine wave
N/A
>95%
N/A
>60%
12V/4.5Ah
1
12VDC
7.9 min
6 hours
N/A
4-6 ms
LED
Yes
100 x 143x 200
3.8kg
0~40°C
<40dB
No
No
No
WxHxD
Operating Temperature
Noise Level
USB
External Slot
TVSS protection
LIN - 14
Line-interactive UPS
UNI Z series
KEY FEATURES
•
Ideal backup power solution for home and office
•
Optimized design leads to cost-saving and space-saving
•
Boost and buck circuit to deal with challenging power conditions
•
Compact size which can be easily fit with PC-related equipment
•
Top access of outlet makes power core connection easier
500
TYPICAL APPLICATION
LIN - 15
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
UNI Z 500
500VA/300W
92~142VAC
42~70 Hz
Single phase with ground
0.6
120VAC
N/A
Voltage Regulation (Battery Mode)
±10%
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ 120W load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
50±1Hz / 60±1Hz
Modified sine wave
N/A
>95%
N/A
>60%
12V/4.5Ah
1
12VDC
7.9 min
6 hours
N/A
4-6 ms
LED
Yes
100 x 143x 200
3.8kg
0~40°C
<40dB
No
No
No
WxHxD
Operating Temperature
Noise Level
USB
External Slot
TVSS protection
LIN - 16
Line-interactive UPS
BLAZER VISTA
KEY FEATURES
series
400 / 600 / 800
•
Equipped with Boost and Buck AVR to stabilize output voltage
•
Built-in DC start function Easy-to-understand graphic LCD display
•
Smart RS232 port for remote monitoring
•
Easy battery replacement design
•
Auto self-charge under off status
•
Auto self-restart upon AC recovery
•
Surge protection for modem or phone lines
•
Protection against over-charge, over-discharge, over-loading
1000 / 1400 / 2000
TYPICAL APPLICATION
LIN - 17
Line-interactive UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
BLAZER VISTA 800
800VA/480W
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Line Mode)
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Line Mode
AVR Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
BLAZER VISTA 400
BLAZER VISTA 600
400VA/240W
600VA/360W
162-290VAC
45~55/55~65 Hz
Single phase with ground
0.6
220/230/240VAC
±15%
±10%
50/60Hz±1Hz
Modified sine wave
No
>95%
>88%
>60%
12V/4.5Ah
12V/7Ah
1
1
12VDC
12V/9Ah
1
12V/7Ah
2
24VDC
12V/9Ah
2
Backup Time (@ typical PC load)
10 min
22 min
40 min
45 min
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
8 hours
1A
2-6 ms
LCD
YES
100X140X330
4.3 kg
0- 40°C
<40dBA
Yes/Optional
Yes
10 hours
4-6 ms
6 hours
0.7A
4-8 ms
205X145X405
9.6 kg
9.7 kg
WxHxD
Operating Temperature
Noise Level
RS232/USB
TVSS protection
18 min
4.97 kg
BLAZER VISTA 1000
1000VA/600W
166~290VAC
45~55/55~65 Hz
BLAZER VISTA 2000
2000VA/1200W
±5%
6.15 kg
<45dBA
LIN - 18
BLAZER VISTA 1400
1400VA/840W
9.8 kg
Standby UPS
APFC OFFICE
KEY FEATURES
series
•
Supports loads with APFC (Active Power Factor Correction)
switch power supply with patented design
400 / 600
•
Quick installation and easy to operate
•
Easy battery replacement
•
Surge protection for all receptacles
•
Jack for phone/model lines with surge protection
•
Easy-to-understand LED indicator
•
Protection against faults and overloading
800
TYPICAL APPLICATION
APFC loads
STB - 01
Standby UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Line Mode
Battery Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ typical PC load)
Recharge Time (to 90%)
Charging Current
Battery Mode ↔ Line Mode
WxHxD
Operating Temperature
Noise Level
TVSS Protection
APFC OFFICE 400
400VA/200W
170~270VAC
45~55/55~65 Hz
Single phase with ground
0.5
230VAC
10%
50Hz/60Hz 1Hz
Modified sine wave
>95%
>70%
12V/4.5Ah
1
12V
9 min
< 10 hours
0.5A
2-8 ms
LED
YES
320 x 125 x 86 mm
3.7 kg
0- 40°C
<40dB
Yes
APFC OFFICE 600
600VA/300W
APFC OFFICE 800
800VA/420W
0.525
12V/5Ah
12V/7Ah
17 min
20 min
1A
335 x 170 x 92.5 mm
5 kg
STB - 02
Standby UPS
MAXOFFICE Z
KEY FEATURES
series
•
UL and FCC Part 15 Class B compliant
•
High-frequency design and full-digital control provide optimal
performance
•
Provides professional protections against lightning, surge, spike,
brownout and blackout
425 / 625
•
Battery-replaceable design enables easy maintenance
•
Easy-to-understand LED indicators
•
Pro-active audible alarms
•
Quick installation and easy to operate
TYPICAL APPLICATION
STB - 03
Standby UPS
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
Nominal Frequency
Input Wiring
Output Power Factor
Nominal Output Voltage
OUTPUT
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Battery Type
Number of Internal Battery
BATTERY
Rated Battery Voltage
Backup Time (@ typical PC load)
Recharge Time (to 90%)
TRANSFER TIME Battery Mode ↔ Line Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
ENVIRONMENT Operating Temperature
INTERFACE
TVSS Protection
INPUT
MAXOFFICE Z 425
425VA/225W
120 VAC ± 15%
50/60Hz
Single phase with ground
0.529
120VAC
± 10%
50/60 Hz ± 1Hz
Modified Sine Wave
12V/2.9Ah
1
12V
5~7 min
10 hours
2-6 ms
LED
Yes
125X85X300 mm
2.8 kg
0- 40°C
Yes
MAXOFFICE Z 625
625VA/315W
0.5
12V/4.5Ah
1
7~12 min
3.5 kg
STB - 04
Standby UPS
MAXPOWER
KEY FEATURES
series
1000
•
Microprocessor control guarantees high reliability
•
Built-in DC start function
•
Simple installation and easy to operate
•
Automatic detection of AC mains failure
•
Auto restart while AC recovery
•
Self diagnosis ensures longer battery life
•
Provides discharge, over-charge, and overload protection
(MaxPower 1000 only)
400 / 600
TYPICAL APPLICATION
STB - 05
Standby UPS
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
OUTPUT
Voltage Regulation (Battery Mode)
Frequency Range ( Battery Mode )
Output Waveform
Line Mode
EFFICIENCY
Battery Mode
Battery Type
Number of Internal Battery
BATTERY
Rated Battery Voltage
Backup Time (@ typical PC load)
Recharge Time (to 90%)
TRANSFER TIME Battery Mode ↔ Line Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
INTERFACE
TVSS Protection
INPUT
MAXPOWER 400
400VA/200W
90-145VAC / 170-270VAC
50Hz/60Hz
Single phase with ground
0.5
110/120VAC or 220/230/240VAC
110/120VAC or 220/230/240VAC±10%
50Hz/60Hz 1Hz
Modified Sinewave
>95%
>70%
12V/4.5Ah
1
12V
6~9 min
10 hours
2~6 ms
LED
Yes
80 x 230 x 176.5 mm
2.5 kg
0- 40°C
<45dB
Yes
STB - 06
MAXPOWER 600
600VA/300W
MAXPOWER 1000
1000VA/600W
0.6
12V/7Ah
1
12V/7.2Ah
2
13~20 min
30 min
3.1 kg
90.6 x 237.7 x 280 mm
6.5 kg
Standby UPS
DC UPS
KEY FEATURES
series
• Ideal backup power solution for DC-powered equipment (e.g.
network and telecom)
• Integrated hot-swappable for battery replacement
• Universal input range (80~260VAC) for global application
• Microprocessor controlled for optimized performance and
reliability
• Supports cold-start function
• Easy-to-understand LED indicators
TYPICAL APPLICATION
STB - 07
Standby UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
INTERFACE
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Output Voltage Range
Output current
Line Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time (@ 1A discharging)
Recharge Time (to 90%)
Charging Current
WxHxD
Operating Temperature
Output Terminal (7 pin)
DC UPS
30W
80~260VAC
45Hz~65Hz
Single phase with ground
1
12VDC
10.5~13.8VDC
2.2A max
>80%
12V/7Ah
1
12VDC
340 min
4 hours
2.5A max
LED
Yes
120x348x80 mm
4 kg
0 – 40 ℃
2 pin for DC output, 5 pin for dry contact
STB - 08
Modular UPS
GRIPOWER PRO series
KEY FEATURES
• Supports up to 10x15KVA UPS modules up to 150KVA output capacity
• Hot-swappable UPS module with wireless design
• N+X parallel redundant configuration which leaves no SPOF (Single Point of
Failure)
• 7” colorful touch-screen LCD
• Easy installation and load expansion resulted from modular design
• 3 multi-function intelligent ports which support USB, RS232, SNMP, AS400,
NMC, and CMC cards
• Optimized performance with >93% efficiency
• Supports AC generator as AC input
• Configurable battery quantity from 32 to 42 pieces per set
TYPICAL APPLICATION
power module
MDL - 01
Modular UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
Each Module
Max. Module in Parallel
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Gripower Pro
15KVA/13.5kW
10
304-520 VAC
40-70 Hz
3-phase/4-wire + PE
<5% @ 100% RCD load
Output Power Factor
0.9
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery & Converter
Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Cabinet Parallel Operation
Inverter Mode
Battery Mode
Battery Connection
Number of Battery
Rated Battery Voltage
Charging Current per Module
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
353/380/400/415 VAC
±1%
50/60Hz ±0.05Hz
DISPLAY
AUDIBLE ALARM
2.5:1
<2% @ linear load, <4% @ non-linear load
Pure sine wave
N/A
93%
93%
External
32~40 pcs
± Kx12 VDC (K = 16 to 20)
3.5A
0 ms
0 ms
7” touch panel LCD
Yes
CABINET DIMENSION WxHxD
600x2030x1000
NET WEIGHT
90KVA: 230kg / 120KVA: 265kg150KVA: 275kg
0 – 40 ℃
<62dBA
Yes
Supports SNMP/AS400/NMC/CMC card
Yes
EFFICIENCY
BATTERY
TRANSFER TIME
ENVIRONMENT
INTERFACE
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
MDL - 02
3-Phase UPS
50K / 60K / 80K
APUS series
KEY FEATURES
•
3-Phase, double-conversion online UPS
•
Up to 98% efficiency under High Efficiency mode results in significant
energy saving
40K
•
Intelligent management of battery charging prolongs battery lifetime
•
Pre-wired for easy installation
•
Up to 35% smaller than similar competitive solutions
•
Allows dedication of more floor space to revenue producing equipment
30K
15K / 20K
TYPICAL APPLICATION
3PH - 01
3-Phase UPS
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range
( Battery Mode )
Current Crest Ratio
Voltage Distortion (THDv)
Output Waveform
Parallel Operation
Inverter Mode
ECO Mode
Battery Type
Number of Internal Battery
Rated Battery Voltage
Backup Time
APUS 15K
APUS 20K
15KVA/13.5KW
20KVA/18KW
190~478VAC
42~70Hz
3 phases + Neutral + PE
<5%
0.9
380/400/415VAC
1%
APUS 30K
30KVA/27KW
APUS 40K
40KVA/36KW
APUS 50K
50KVA/45KW
3:1
2% with linear load, <5% with non-linear load
Pure sine wave
Yes
94%
98%
N/A
N/A
384VDC / 408VDC / 432VDC
N/A
N/A
Charging Current
Battery Mode ↔ Inverter Mode
Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Inverter Mode
5.3A
0ms
0ms
4ms
Graphical LCD, 4x LEDs
Yes
8A
10.6A
16A
DIMENSION
WxHxD (mm)
500 x 960 x 710
500 x 1230 x 710
500 x 1500 x 710
600 x 1880 x 800
NET WEIGHT
(without battery)
Operating Temperature
Noise Level
RS232/USB
External Slot
Emergency Power Off
TBD
0-40C
≤55dB @ 75% Load
Yes
Yes
Yes
DISPLAY
AUDIBLE ALARM
ENVIRONMENT
INTERFACE
APUS 80K
80KVA/72KW
50/60 Hz  0.005Hz
Recharge Time (to 90%)
TRANSFER TIME
APUS 60K
60KVA/54KW
≤62dB @ 75% Load
3PH - 02
≤65dB @ 75% Load
24A
3-Phase UPS
APUS Z
KEY FEATURES
series
•
Double-conversion online UPS
•
Up to 98% efficiency under High Efficiency mode results in significant
energy saving
40K / 60K
•
Intelligent management of battery charging prolongs battery lifetime
•
Pre-wired for easy installation
•
Up to 35% smaller than similar competitive solutions
•
Delivers up to 21 minutes backup time
•
Allows dedication of more floor space to revenue producing equipment
•
UL compliant
20K / 30K
TYPICAL APPLICATION
3PH - 03
3-Phase UPS
SPECIFICATION
MODEL
CAPACITY
Nominal Input Voltage
Input Voltage Range
Frequency Range
Input Wiring
Current Distortion (THDi)
Output Power Factor
Nominal Output Voltage
Voltage Regulation
OUTPUT
Frequency Range ( Battery Mode )
Output Waveform
Parallel Operation
Inverter Mode
EFFICIENCY
HE Mode
Battery Type
BATTERY
Backup Time (@ full load)
Battery Mode ↔ Inverter Mode
TRANSFER TIME Inverter Mode ↔ Bypass Mode
ECO Mode ↔ Inverter Mode
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
RS232/USB
INTERFACE
External Slot
Emergency Power Off
INPUT
APUS Z 20K
20KVA/16KW
208 / 220VAC
APUS Z 30K
30KVA/24KW
176.8~250VAC
40~72Hz
3Ph+N+PE
< 5%
0.8
208/220VAC (3-phase, 4-wire)
±1%
50Hz/60Hz
Pure sine wave
Up to 4 units
92%
98%
12V/9Ah
21 min
12 min
0ms
0ms
TBD
LCD
Yes
530 x 800 x 1360 mm
476kg
0-30°C
<64dB @ 1 meter
Yes
2 mini-slots for SNMP/CMC/AS400 Card
Yes
3PH - 04
APUS Z 40K
40KVA/32KW
APUS Z 60K
60KVA/48KW
10 min
5 min
600 x 800 x 1880 mm
680kg
AC Inverter
HYBRID INVERTER series
KEY FEATURES
•
•
•
•
•
•
•
•
•
Ideal energy saving solution for home/office applications
Supports AC generator as input
Reliable backup power supported by both PV (solar) system and battery
bank
Batteries can be charged by both PV system and AC input
Automatically switches between 9 operation modes to optimize the
energy consumption
Built-in 20/35A battery charger
Built-in 40A circuit breaker
Built-in MPPT * for optimized PV energy harvest
Compliance with CE
TYPICAL APPLICATION
ACI - 01
AC Inverter
SPECIFICATION
MODEL
CAPACITY
SOLAR INPUT
No. of MPPT
Max. Input Power
Initial Feed-in Voltage
Working Voltage Range
Full-rating Voltage Range
Input Voltage Waveform
Input Voltage Range
LINE MODE
(AC mains are normal)
Input Frequency Range
Output Voltage Waveform
Output Short-circuit Protection
Efficiency (Line Mode)
Transfer Time (AC↔DC)
BATTERY MODE
(AC mains are failed)
BATTERY CHARGER
DISPLAY
PROTECTION DEGREE
DIMENSION
NET WEIGHT
ENVIRONMENT
Nominal Battery Input Voltage
Min. Startup Voltage1
Output Voltage Waveform
Nominal Output Voltage
Output Voltage Regulation
Output Frequency
Efficiency
Supported Battery Type
Nominal Battery Voltage
Min. Battery Startup Voltage1
Charger Current2
WxHxD
Operating Temperature
Noise Level
Hybrid 5048E
5000VA/4200W
1
4500W
160VDC
130-300VDC
185-300VDC
Sinewave (mains or generator)
170-280VAC (normal range)
90-280VAC (generator/wide range)
40-65Hz
Same as input
Built-in 40A circuit breaker
>95% @R-load
10ms (normal range setting)
20ms (generator/wide range setting)
48VDC
40VDC
Sinewave
230VAC
10%
50Hz / 60Hz  1Hz
>95%
flooded lead-acid or sealed GEL/AGM lead-acid battery
48VDC
35VDC
20/35A (user-configurable)
2 x LCD, 3 x LED indicators
IP20
192x370x456 mm
17.2kg
0-45℃
60dB
Note:
1. Hybrid 5048E can only be started up with battery (>35V).
2. Total capacity of external batteries shall be no less than 100AH.
ACI - 02
AC Inverter
INVEREX
KEY FEATURES
series
•
Able to be configured to accept wider input voltage
•
Rack/Tower dual set-up design
•
Off-mode battery charging capability
•
Built-in 10 Amp super charger for up to 100Ah battery
•
Two-steps intelligent charging control to reduce the
recharging time
500 / 1000 / 2000
TYPICAL APPLICATION
ACI - 03
AC Inverter
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
INPUT
OUTPUT
EFFICIENCY
BATTERY
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Output Waveform
AC to AC
DC to AC
Battery Type
Number of Internal Battery
Rated Battery Voltage
Charging Current
Battery Mode ↔ Line Mode
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
INVEREX 500
500VA/300W
170-280VAC (Normal Range)
90-280VAC (Wide Range)
>40Hz
Single phase with ground
0.6
220/230/240 VAC
-18%~10%
50/60 Hz  0.01Hz
Modified sine wave
>95%
>80%
Lead-acid battery
N/A
12V
10A
15ms typical, 40ms max
LED
Yes
255 X 80 X 224 mm
2 kg
0- 40°C
<50dB
INVEREX 1000-I
1000VA/600W
INVEREX 1000-II
1000VA/600W
INVEREX 2000-I
2000VA/1200W
24V
2.1 kg
ACI - 04
2.3 kg
2.5 kg
AC Inverter
INVEREX S
KEY FEATURES
series
•
High-frequency switching technology for compact size and light weight
•
Pure sine wave output for wide range of applications and harsh
environment
3024E
•
High efficient(>90%) DC-to-AC conversion minimizing energy loss
•
“Power Saving Mode” to conserve energy for less than 10W
•
Easy-to-understand graphic LCD display
•
Protections against Input low voltage / Overload / Short circuit / Low
battery alarm/ Input over voltage / Over temperature
TYPICAL APPLICATION
5048E
ACI - 05
AC Inverter
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
Input Voltage Range
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Output Waveform
Motor Load Capacity
AC to AC
DC to AC
Battery Type
Number of Internal Battery
Rated Battery Voltage
Charging Current
Battery Mode ↔ Line Mode
WxHxD
Operating Temperature
Noise Level
INVEREX S 3024E
3000VA/2400W
90~280Vac
40~65Hz
Single phase with ground
0.8
230Vac
10%
50/60 Hz  1Hz
Pure sine wave
1.5HP
>95%
>90%
Flooded/AGM/Gel lead-acid
N/A
24VDC
20A
10 ms typical, 15 ms max
LCD
Yes
268X76X323 mm
4.9 kg
0- 45°C
≦60dB
ACI - 06
INVEREX S 5048E
5000VA/4200W
170~280Vac
0.84
2.5HP
VRLA/ Flooded/AGM/Gel lead acid
48VDC
20A / 35A (user configurable)
350X110X407 mm
9 kg
AC Inverter
INVEREX Z series
KEY FEATURES
•
Designed for 110/120VAC AC grid system
•
Able to be configured to accept wider input voltage
•
Rack/Tower dual set-up design
•
Off-mode battery charging capability
•
Built-in 10 Amp super charger for up to 100Ah battery
•
Two-steps intelligent charging control to reduce the
500 / 1000 / 2000
recharging time
TYPICAL APPLICATION
ACI - 07
AC Inverter
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
INPUT
OUTPUT
EFFICIENCY
BATTERY
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Output Waveform
AC to AC
DC to AC
Battery Type
Number of Internal Battery
Rated Battery Voltage
Charging Current
Battery Mode ↔ Line Mode
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
WxHxD
NET WEIGHT
Operating Temperature
ENVIRONMENT
Noise Level
INVEREX Z 500
500VA/300W
90-145VAC (Normal Range)
50-145VAC (Wide Range)
>40Hz
Single phase with ground
0.6
220/230/240 VAC
-18%~10%
50/60 Hz  0.01Hz
Modified sine wave
>95%
>80%
Lead-acid battery
N/A
12V
10A
15ms typical, 40ms max
LED
Yes
255 X 80 X 224 mm
2 kg
0- 40°C
<50dB
INVEREX Z 1000-I
1000VA/600W
INVEREX Z 1000-II
1000VA/600W
INVEREX Z 2000-I
2000VA/1200W
24V
2.1 kg
ACI - 08
2.3 kg
2.5 kg
AC Inverter
INVEREX HD
KEY FEATURES
series
1000 / 2000
•
Ideal backup power solution for home / workplace
•
Ready for appliances such as TV, stereos and lights
•
High conversion efficiency (>95%) results in energy saving
•
High output power factor (0.72-0.8)
•
Easy-to-understand LCD and LED indicators
•
Design for both stand and wall-mounted setup
•
User-selectable charging current allows flexible battery configuration
•
Intelligent battery charging control
•
Protection against over-charging and over-loading
TYPICAL APPLICATION
ACI - 09
AC Inverter
SPECIFICATION
MODEL
CAPACITY
Input Voltage Range
INPUT
OUTPUT
EFFICIENCY
BATTERY
TRANSFER TIME
DISPLAY
AUDIBLE ALARM
DIMENSION
NET WEIGHT
ENVIRONMENT
Frequency Range
Input Wiring
Output Power Factor
Nominal Output Voltage
Voltage Regulation
Frequency Range ( Battery Mode )
Output Waveform
AC to AC
DC to AC
Battery Type
Number of Internal Battery
Rated Battery Voltage
Charging Current
Battery Mode ↔ Line Mode
WxHxD
Operating Temperature
Noise Level
INVEREX HD 1000
1000VA/800W
170~280VAC (normal range)
90~280VAC (wide range)
Single phase with ground
0.8
230Vac
-18%~+10%
50/60 Hz  1%
Modified sine wave
>95%
>80%
Lead-acid battery
N/A
12V
15A / 20A (user configurable)
15ms typical, 40ms max.
LCD/LED
Yes
220X87X252 mm
2.2 kg
0- 50°C
<50dB
ACI - 10
INVEREX HD 2000
2000VA/1440W
0.72
24V
10A
Solar Charger Controller
SOLAR MATE
KEY FEATURES
series
12 / 24V
•
High conversion efficiency
•
Able to supply power to DC loads for extensive applications
•
Built-in MPPT (Maximum Power Point Tracker) to optimize energy harvest
•
Supports various types of battery with tailor-made charging profiles
•
3-stage battery charging control (bulk, absorption, and float charging)
•
Overload and lightning protection
•
Protection for reversed polarity of PV panel and batteries
•
Real-time charging status and fault events are shown by LED indicators
36 / 48V
TYPICAL APPLICATION
SCC - 01
Solar Battery Charger
SPECIFICATION
Model
Battery Voltage Setting (user configurable)
Input Voltage Range
Rated Charging Current
Load Current
Max. PV Input Voltage
Idle Current Consumption
Over Load Protection (DC load)
Bulk Charge
Float Charge
Over Charge Disconnection
Over Charge Recovery
Over Discharge Disconnection
Over Discharge Reconnection
Low Voltage Reconnect
Low Voltage Disconnect
Operating Temperature
Cooling Method
Protection Degree
Terminal Wiring Size
Dimension WxHxD
Net Weight
SolarMate 12/24V
12VDC
15-55VDC
40 A
15 A
55VDC
<10mA
30 >5s
22.5A >20s
18.8A (de-rating)
14.6 VDC (default)
13.4 VDC (default)
14.8 VDC
13.6V
10.8V
12.3V
13± 1 VDC
11.5± 1 VDC
0-40℃
Natural cooling
IP21
AWG # 8
140 x 66 X 192 mm
1.4 kg
SolarMate 36/48V
36VDC
40-150VDC
24A
7A
150VDC
24VDC
29.2 VDC (default)
26.8 VDC (default)
29.6VDC
27.2V
21.6V
24.6V
26.0± 2VDC
23.0± 2VDC
14A>5s
10.5A >20s
8.8A (de-rating)
43.8 VDC (default)
40.2 VDC (default)
47.4 VDC
42.0 VDC
32.4 VDC
36.9 VDC
36.9 ± 0.3 VDC
32.4 ± 0.3 VDC
0-50℃
IP20
AWG # 20~6
220 X 311 X 124 mm
5.4 kg
SCC - 02
48VDC
58.4 VDC (default)
53.6 VDC (default)
63.2VDC
56.0 VDC
43.2 VDC
49.2 VDC
49.2 ± 0.3 VDC
43.2 ± 0.3 VDC
Solar Inverter
GRID-TIED, SINGLE-PHASE
SUNVILLE series
KEY FEATURES
SV1500
SV1500
SV2800
•
•
Transformer-less design
Ideal for indoor residential installation
•
High conversion efficiency (up to 95%~96%)
•
Wide operational range for DC input voltage/current
•
IP43 sheet metal enclosure for SV1500~4000
•
IP 65 sheet metal enclosure for SV4000A & SV6000
•
Dot-matrix LCD display
•
Compliance with VDE0126-1-1
•
Powerful communication interfaces (RS485)
SV4000
TYPICAL APPLICATION
SV6000
SV4000A
SLI - 01
Solar Inverter
SPECIFICATION
MODEL
CAPACITY
INPUT (DC)
OUTPUT (AC)
EFFICIENCY
GENERAL
No. of MPPT 1
Max. PV Input Voltage
Max. PV Input Current
Initial Feed-in Voltage
Working Voltage Range
Full-rating Voltage Range
MPPT Efficiency
DC Insulation Resistance
Nominal Output Voltage
Nominal Output Frequency
Output Wiring
Max. AC Output Current
Power Factor
Operational Voltage Range
Operational Frequency Range
Current Harmonic (THDi)
Maximum
Weighted Average2
Topology
Protection Degree
Standby Consumption/night
Operational Temperature Range
Humidity
GRID STANDARD
INTERFACE
DIMENSION
WxDxH
NET WEIGHT
1. MPPT: Maximum Power Point Tracker
2. European efficiency
SV 1500
SV 2000
1500W
2000W
1
450V
500V
8.9A
10A
150V
150~405V
150~450V
200~405V
250~405V
>99%
>5M
230V
50/60Hz
Single phase with ground
7.9A
10.5A
>0.99
184~264.5V
47.5~50.2Hz
<3%
95%
96%
94%
95%
Transformerless
IP43
< 7W / < 0.1W
-20 ~ +55℃
0 to 95%, non-condensing
VDE0126-1-1
RS232 port / RS485 card slot
315X120X269mm
350X120X302mm
9.2 kg
11.5 kg
SLI - 02
SV 2800
2800W
SV 4000
4000W
SV 4000A
4000W
13A
20A
20A
SV 6000
6000W
3
750V
8.5A/tracker
125~700V
450~750V
14.3A
16.5A
20A
25.5A
94%
IP65
< 8W / < 0.1W
350X136X302mm
12.8 kg
424X120X366mm
16.4 kg
434X135X386mm
19.5 kg
430X130X530mm
27 kg
Solar Inverter
GRID-TIED, Three-Phase
SUNVILLE
KEY FEATURES
series
SV10000
•
Transformer-less design
•
Ideal for commercial installation
•
High conversion efficiency (up to 96.5%)
•
Wide operational range for DC input voltage/current
•
Sheet metal enclosure
•
Dot-matrix LCD display
•
Compliance with VDE0126-1-1
•
Powerful communication interfaces (RS485)
TYPICAL APPLICATION
SV12500
SLI - 03
Solar Inverter
SPECIFICATION
MODEL
CAPACITY
INPUT (DC)
OUTPUT (AC)
EFFICIENCY
GENERAL
No. of MPPT1
Max. PV Input Voltage
Max. PV Input Current
Initial Feed-in Voltage
Working Voltage Range
Full-rating Voltage Range
MPPT Efficiency
DC Insulation Resistance
Nominal Output Voltage
Nominal Output Frequency
Output Wiring
Max. AC Output Current
Power Factor
Operational Voltage Range
SV10000
10000W
3
800V
13A/per tracker
350V
245~720V
320~720V
>99%
>5M
400VAC (Line-to-Line)
50/60Hz
3-phase + N + G
17.5A
>0.99
195.5~253VL-N
SV12500
12500W
3
Operational Frequency Range
47.55~51.15Hz
50.15~47.55Hz
Current Harmonic (THDi)
Maximum
Weighted Average2
Topology
Protection Degree
Standby Consumption/night
Operational Temperature Range
Humidity
<3%
96.5%
95%
Transformerless
IP65
<30W/<3.5W
-20 ~ +55℃
0 to 95%, non-condensing
VDE0126-1-1
RS232 port / RS485 card slot
585X152X454mm
34 kg
GRID STANDARD
INTERFACE
DIMENSION
WxHxD
NET WEIGHT
1. MPPT: Maximum Power Point Tracker
2. European efficiency
SLI - 04
245~720V
400~720V
20A
195.5~257.6VL-N
96.5%
95%
550X200X553mm
45 kg
AVR
HOSTA series
KEY FEATURES
•
Provides high quality AC power to support sensitive equipment and
loads
•
Automatically switches between buck and boost operation
•
Wide input voltage range
•
Auto-restart after AC mains’ recovery
•
Easy-to-read LCD and LED indicators
•
High efficiency design minimizes energy loss
•
Provides over-temperature, short-circuited protection
1000
TYPICAL APPLICATION
AVR - 01
AVR
SPECIFICATION
MODEL
CAPACITY
Nominal Input Voltage
Nominal Frequency
Input Voltage Range
Nominal Output Voltage
Boost 1 Mode Voltage
Boost 2 Mode Voltage
Boost 3 Mode Voltage
Boost 4 Mode Voltage
Buck Mode Voltage
Output Frequency
HOSTA 1000
600VA/600W
220VAC
50Hz
120~260VAC
220 VAC
Vin×1.1
Vin×1.2
Vin×1.3
Vin×1.42
Vin×0.9
Same as Input
Voltage Regulation (Line Mode)
+8% / -30% @330W loading
Output Power Factor
Line Mode
1
>98%
EFFICIENCY
Boost Mode
Boost 1: 96%/ Boost 2: 94%/ Boost 3: 92%/ Boost 4: 84%
ENVIRONMENT
Buck Mode
Operating Temperature
Noise Level
WxHxD
>96%
0-50℃
<35dB
200x80x135 mm
1.95kg
INPUT
OUTPUT
DIMENSION
NET WEIGHT
AVR - 02
AVR
VANDA series
KEY FEATURES
•
Provides high quality AC power to support sensitive equipment
and loads
•
Automatically switches between buck and boost operation
•
Wide input voltage range
•
High efficiency design minimizes energy loss
•
Provides over-loading, over-temperature, over-voltage protection
1000 / 2000
TYPICAL APPLICATION
AVR - 03
AVR
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
ENVIRONMENT
DIMENSION
NET WEIGHT
Nominal Input Voltage
Nominal Frequency
Input Voltage Range
Nominal Output Voltage
Boost2 Mode Voltage
Boost1 Mode Voltage
Buck Mode Voltage
Output Frequency
Voltage Regulation (Line Mode)
Output Power Factor
Line Mode
Boost1/Boost2
Buck
Operating Temperature
Noise Level
WxHxD
VANDA 1000
1000VA/600W
220 VAC
50 Hz
165-253 VAC
220 VAC
Vin×1.2
Vin×1.1
Vin×0.92
Same as Input
-10%~+6%
0.6
>98%
>95%
>95%
0-40℃
< 50dB
111 x 135 x 215 mm
3.46 kg
VANDA 2000
2000VA/1200W
4.18 kg
AVR - 04
AVR
IBERIS series
KEY FEATURES
•
Provides high quality AC power to support sensitive equipment
and loads
800 / 1000 / 1600 / 2000
•
Automatically switches between buck and boost operation
•
Wide input voltage range
•
Easy-to-understand LED indicators
•
High efficiency design minimizes energy loss
•
Surge protection for phone/modem line
TYPICAL APPLICATION
AVR - 05
AVR
SPECIFICATION
MODEL
CAPACITY
INPUT
OUTPUT
EFFICIENCY
ENVIRONMENT
DIMENSION
NET WEIGHT
Nominal Input Voltage
Nominal Frequency
Input Voltage Range
Nominal Output Voltage
Boost Mode Voltage
Buck Mode Voltage
Output Frequency
Voltage Regulation (Line Mode)
Output Power Factor
Line Mode
Boost
Buck
Operating Temperature
Noise Level
WxHxD
IBERIS 800
800VA/400W
120/220 VAC
50/60 Hz
80-138/180-288 VAC
120/220 VAC
IBERIS 1000
1000VA/500W
Same as Input
0.5
95%
92%
92%
0-40℃
< 40dB
281 mm X 90 mm X 120 mm
4.18 kg
AVR - 06
IBERIS 1600
1600VA/800W
IBERIS 2000
2000VA/1000W
Accessory
NMC Card
•
•
•
•
KEY FEATURES
Ideal monitoring solution enables user to monitor and control the
status of UPS on web browser via internet
Communicates with UPS and respond to Network Management System
using SNMP (Simple Network Management Protocol)
Supports RTC (Real-Time-Clock)
Supports software to shutdown server or client operating system safely
during the power failure
NMC: Network Management Card
AS400 Card
•
KEY FEATURES
Provides voltage-free dry-contact signals for programmable controller
and management system
•
Ideal to work with server, personal computer and workstation
•
Support external alarm, fault indicator, status indicator, bypass and
remote shutdown
CMC Card
KEY FEATURES
• Easy solution for remote monitoring and control
• Converts the UPS RS232 signal new RS232 signal with specified address
• Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex)
• Provides a pair of RJ45 interface
CMC: Central Monitoring Card
ACC - 01
Accessory
•
Network Management Card
Mini NMC Card
•
•
•
•
KEY FEATURES
Ideal monitoring solution enables user to monitor and control the
status of UPS on web browser via internet
Communicates with UPS and respond to Network Management System
using SNMP (Simple Network Management Protocol)
Supports RTC (Real-Time-Clock)
Supports software to shutdown server or client operating system safely
during the power failure
NMC: Network Management Card
Mini AS400 Card
•
KEY FEATURES
Provides voltage-free dry-contact signals for programmable controller
and management system
•
Ideal to work with server, personal computer and workstation
•
Support external alarm, fault indicator, status indicator, bypass and
remote shutdown
Mini CMC Card
KEY FEATURES
• Easy solution for remote monitoring and control
• Converts the UPS RS232 signal new RS232 signal with specified address
• Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex)
• Provides a pair of RJ45 interface
CMC: Central Monitoring Card
ACC - 02
Accessory
Relay Card
•
•
•
•
•
Provides voltage-free dry-contact signals for programmable
controller and management system
5 output relay signals
1 input signal for remote on/off and UPS shutdown
Configurable normal-open or normal-close signal
Configurable delay time
USB/RS232 Card
•
•
•
KEY FEATURES
KEY FEATURES
Adds USB and RS232 ports on compatible UPS
Enables the remote monitoring and control of UPS via the USB and
RS232 ports
Compatible with monitoring software - Winpower
KEY FEATURES
EMP
•
•
•
Supports temperature and humidity sensors for remote environment
monitoring
Works with NMC card to monitor the readings using web browser and
send notification when the reading exceeds pre-set limits
Measures temperature from 0~70℃ and humidity from 10~90%
EMP: Environmental Monitoring Probe
ACC - 03
Accessory
External Charger
•
•
•
•
•
Two models for different charging current: 8A and 20A
273V charging voltage
90% efficiency
3 LED indicators to show the charging modes and status
Built-in fuse at AC input
ATS
•
•
•
•
•
KEY FEATURES
KEY FEATURES
Serves as power source selector
Back-feed protection
Over-loading, short-circuit protection
Supports RPO (Remote Power Off)
Supports remote monitoring for input and output
ATS: Automatic Transfer Switch
ACC - 04
Accessory
COMPATIBILITY MATRIX
Name
Part Number
Titan (Vista) 1-3K
Titan (Vista) 6-20K
Innova 1-3K
Innova 6-10K
Innova Combo 10-20K
Innova RT 1-6K
Innova RT 10K
JAGA 1-3K
Gripower Pro
Claire 750-3000
Spring RT 1000-3000
Name
Part Number
Titan (Vista) 1-3K
Titan (Vista) 6-20K
Innova 1-3K
Innova 6-10K
Innova Combo 10-20K
Innova RT 1-6K
Innova RT 10K
JAGA 1-3K
Gripower Pro
Claire 750-3000
Spring RT 1000-3000
USB/RS232 Card
730-80208-00P
AS400 Card (White)
730-50024-02P
AS400 Card (Black)
730-80135-00P
●
●
●
●
●
●
●
●
●
●
●
●
●
●
AS400SC Card
744-15568-00P
Mini AS400 card
730-80141-00P
Mini AS400 card
730-80197-00P
Relay Card
730-80235-00
○
○
●
●
●
●
●
●
●
●
●
●
CMC Card
730-80118-00P
Mini CMC Card
730-80100-00P
●
●
●
●
●
●
●
NMC Card
730-80348-00P
Mini NMC Card
730-80349-00P
●
●
●
●
●
●
●
●
●
●
●
●
EMP for NMC Card 8A External Charger 12A External Charger
744-A2460-00P
730-80083-00P
730-80084-00P
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
○: not fully supported
ACC - 05
• Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan •TEL: +886-2-2794-6363 • Fax: +886-2-6606-8711 • Website: www.centralion.com
Copyright © 2014 Centralion Industrial Inc. All Rights Reserved.