Liquid Pumps - MAXPRO Technologies Inc.

Transcription

Liquid Pumps - MAXPRO Technologies Inc.
MAXIMATOR® AIR DRIVEN
Liquid Pumps
LC SERIES
PRESSURES FROM 420 TO 15,000 PSI
PPO SERIES
PRESSURES FROM 60 TO 14,500 PSI
S & S-D SERIES
PRESSURES FROM 105 TO 15,000 PSI
LO SERIES
PRESSURES FROM 165 TO 14,500 PSI
GXO SERIES
PRESSURES FROM 540 TO 14,500 PSI
PP SERIES
PRESSURES FROM 60 TO 60,000 PSI
L SERIES
PRESSURES FROM 165 TO 60,000 PSI
L-D SERIES
PRESSURES FROM 165 TO 38,425 PSI
GX SERIES
PRESSURES FROM 540 TO 15,225 PSI
PPSF SERIES
PRESSURES FROM 60 TO 14,500 PSI
LSF SERIES
PRESSURES FROM 165 TO 23,200 PSI
MAXPRO CUSTOM DESIGNED
Power Packs, Pump Skids,
Portable Test Carts and Test Benches
MAXIMATOR
®
Liquid Pumps
AIR DRIVEN FROM 60 PSI TO 60,000 PSI
Maximator high efficiency pumps are ideal for a broad variety of oil, water and chemical applications.
They feature a large air piston joined to a smaller diameter plunger. The pressure ratio is the ratio
of these two areas and is the method of determining maximum output pressure. Higher pressures
are obtained by using higher pressure ratios. Maximator model numbers reflect the pump’s
nominal pressure ratios, while the technical data indicates exact ratios.
Maximator hydraulic pumps cycle automatically. The pump stops automatically when
the output pressure forces and the air drive forces are equal. The pump restarts with a slight drop
in the outlet pressure or an increase in the air drive pressure.
FEATURES
I
I
I
I
I
I
I
I
Easy to install and operate
Pressure maintained without energy consumption
Explosion proof ... no electrical power required
Pilot air control for remote operation standard on many models
External spool valve for quick maintenance on most models
Dry air spool valve option available for severe service applications
Chemical service pumps are standard with separation fitting
Optional seal materials, port connections, double acting, multiple air heads,
single stroke, adjustable stroke, special pumps, just ask!
HOW TO SELECT A MAXPRO PUMP
Index
Page
How to Select a MAXPRO Pump
2
Installation and Maintenance
2
Oil or Oil/Water Service
LC Series
PPO Series
S Series
S-D Series
LO Series
GXO Series
3
4-5
6
7
8
9
Water or Oil Service
PP Series
L Series
L-D Series
GX Series
10-11
12-14
15
16
Chemical Service
PPSF Series
LSF Series
17-18
19-20
Accessories
Portable Systems
21
1. Consider the type of fluid to be pumped and compatible materials.
2. Know the available minimum plant air pressure.
3. Determine the required outlet pressure.
4. Determine the required flow rate.
5. Feel free to consult your distributor or MAXPRO for application assistance.
Flow rates for each pump, at various air drive pressures and outlet pressures, are
provided in the catalog. These pumps run very rapidly at no load and slow down as pressure
increases. The pump will eventually come to a stop at the “stall” pressure, which is the air drive
pressure times the pressure ratio of the pump. At this “stall” point there is no flow and no air
consumption. The pump will hold the outlet pressure indefinitely and will only stroke if the outlet
pressure drops or the air drive pressure is increased.
INSTALLATION AND MAINTENANCE
I
I
I
I
I
I
I
22-23
I
2
Maximator pumps can be installed in any position, but vertical is best for longest seal life.
All connections to the pump, both liquid (inlet and outlet) and air drive lines, must be run
with equal or greater size than the connections to the pump.
The maximum recommended height of a pump suction above the fluid level is 10 ft. for LO and L
pumps, 7 ft. for S pumps, and 3 ft. for PPO and PP pumps. Operate pump slowly during initial prime.
Drive air should be filtered between 5µ and 40µ and have a maximum dewpoint of 50°F. Very wet
air will wash out lubricant and cause exhaust icing. Very dry air (dew point below 0°F) will dry out
lubricant and cause premature failure of spool o-rings and requires the use of Dry Air Spool option.
Pumped liquids should be filtered at 100µ or better, viscosity between 1-100 cst.
Pump performance is affected by many operating conditions. Extreme temperatures, pressures,
and high duty cycles will increase maintenance frequency.
All units are lubricated at the factory with silicone free semi-synthetic grease. After 2-3 months
of normal (50% duty) operation, the standard spool seals should be inspected for wear and
relubricated. Based on this inspection, future maintenance intervals can be planned and further
disassembly and lubrication of other moving seals may be necessary. Optional Dry Air Spool
seals require less maintenance.
MAXPRO offers complete technical and service support for all Maximator pumps.
Customer service is our priority!
Thi
spr
oducti
s
nol
ongeravai
l
abl
e.
OIL or OIL/WATER SERVICE
PPO
PPO pumps are lightweight and rugged making them ideal for portable power
packs and are available in eight pressure ratios as listed below. PPO pumps
are single acting, single air drive head types.
SERIES
I
PRESSURES FROM
60 TO 14,500 PSI
I
PILOT
VALVE
I
AIR EXHAUST
MUFFLER
SPOOL
VALVE IN
TOP CAP
AIR
INLET
I
I
AIR CYLINDER
WITH PISTON
«
PUMP
HEAD
«
DISCHARGE
SUCTION
Anodized aluminum bodies and plungers on the PPO4-PPO12,
cast iron bodies on the PPO22-PPO189. Tool steel plungers and
polyurethane seals on all.
All PPO series pumps are standard with bottom inlet. For a side
inlet, add – S to the catalog number.
Maximum air drive pressure is 145 psi. PPO pumps require
less drive pressure because the pump is driven in both
directions with no spring under the piston. This design reduces
noise and provides less chance of cavitation.
Minimum air drive pressure 15 psi.
For air control option ... add – ACM to catalog number.
TECHNICAL DATA
CATALOG
NUMBER
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
PPO4
PPO8
PPO12
PPO22
PPO37
PPO72
PPO111
PPO189
NOTE:
1:4
1:9
1:14
1:29
1:47
1:88
1:133
1:225
DISPL.
PER
CYCLE
(IN.3)
580
1,305
2,030
4,205
6,815
12,760
14,500
14,500
1.86
0.90
0.57
0.28
0.17
0.09
0.06
0.04
CONNECTIONS
INLET
OUTLET
1
1/2
3/4
1/2
3/4
1/2
3/8
1/4
3/8
1/4
3/8
1/4
3/8
1/4
3/8
1/4
WEIGHT
(LBS.)
6
7
Air drive inlet connection on all PPO pumps is 1/4" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches) — PPO4 - PPO12
CATALOG
NUMBER
A
B
C
PPO4
1.88
9.06
4.44
PPO8
1.75
8.44
3.88
PPO12
1.75
8.44
3.88
3.31
3.13
1.941
0.31
3.38
0.311
DIA.
1.56
0.69
1.19
AIR
INLET
7.001 7.63
LIQUID
OUTLET
B
0.25
C
1.941
A
2.31
4
3.88
NOTE:
1
LIQUID
INLET
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
PPO
DIMENSIONS (inches) PPO22 - PPO189
3.13
3.38
1.56
0.13
1.941
0.31
SERIES
1.19
AIR
INLET
8.75
OPTIONAL
SIDE INLET
PRESSURES FROM
60 TO 14,500 PSI
0.69
6.31
5.681
7.56
0.311
DIA.
0.25
5.38
LIQUID
OUTLET
0.31
LIQUID
INLET
1.941
3.25
NOTE:
2.68
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
FLOW CHART — PPO SERIES
CATALOG
NUMBER
PPO4
PPO8
PPO12
PPO22
PPO37
PPO72
PPO111
PPO189
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
0
500
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
885
905
915
422
430
433
272
275
280
132
136
138
81
83
85
43
44
45
28
29
30
17
17
17
50
50
240
325
160
218
245
110
126
132
74
80
82
42
43
45
27
28
29
15
17
17
OUTLET PRESSURE (PSI)
1000
1500
2000
53
22
82
105
47
68
75
37
41
43
26
27
28
14
17
17
49
85
29
60
70
32
39
42
24
27
28
14
16
16
3000
4000
5000
7500
7
38
12
31
36
16
24
26
12
15
15
15
3
24
33
12
22
25
12
15
15
3
21
2
16
21
9
12
14
10000
12500
60
92
170
69
108
120
63
76
79
39
42
44
26
28
29
14
17
17
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
30
37
56
22
36
39
22
26
27
13
16
16
4
8
16
5
11
13
10
2
9
12
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
5
OIL or OIL/WATER SERVICE
S
S pumps are compact and lightweight and are designed for simple installation
in both static and portable applications. Available in six pressure ratios, S pumps
are ideal for applications demanding fast response times.
SERIES
I
S pumps are single acting, single air drive head types.
Cast iron bodies, carbon steel plungers and polyurethane seals.
All S pumps are standard with side inlet only.
Maximum air drive pressure 145 psi.
Minimum air drive pressure 15 psi.
For air control option ... add – AC to catalog number.
I
PRESSURES FROM
105 TO 14,500 PSI
I
I
TOP
CAP
PILOT
VALVE
I
SPOOL VALVE
ON SIDE OF
TOP CAP
I
TECHNICAL DATA
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
CATALOG
NUMBER
PRESSURE
RATIO
MAXIMUM
OUTLET
PRESSURE
(PSI)
DISPL.
PER
CYCLE
(IN.3)
1:17
2,465
1.73
3/4
1/2
1.20
0.77
0.49
0.27
0.19
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
S15
PUMP
HEAD
«
S25
S35
S60
S100
S150
«
SUCTION
DISCHARGE
NOTE:
1:25
1:39
1:61
1:108
1:156
3,625
5,655
8,845
14,500
14,500
CONNECTIONS
INLET
OUTLET
WEIGHT
(LBS.)
20
Air drive inlet connection on all S pumps is 1/2" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches)
5.31
0.25
CATALOG
NUMBER
A
B
S15
6.63
3.69
S25, S35
6.06
3.00
S60, S100
7.81
4.06
S150
7.81
6.81
3.41
AIR INLET
2.62
8.62
7.81
7.62
3.88
LIQUID
INLET
LIQUID
OUTLET
1.00
3/8 – 16
MOUNTING
TAPS (2)
B
2.12
NOTE:
A
Dimensions are subject to change. Consult factory.
FLOW CHART — S SERIES
CATALOG
NUMBER
S15
S25
S35
S60
S100
S150
6
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
60
90
60
90
60
90
60
90
60
90
60
90
OUTLET PRESSURE (PSI)
0
555
575
400
410
255
265
162
168
92
95
62
65
500
380
480
330
370
230
250
153
163
89
94
61
64
1000
25
310
175
305
185
228
138
156
86
92
60
63
1500
2000
3000
4000
5000
7500
10000
12500
80
50
165
90
137
76
87
56
61
65
35
108
60
82
53
60
71
43
73
47
57
25
26
63
42
53
36
20
42
27
12
60
205
125
200
120
147
82
89
59
62
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 33 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
S-D
S-D pumps are compact and lightweight and are designed for simple installation in both
static and portable applications. Available in six pressure ratios, S-D pumps are ideal for
high flow applications. The S-D pumps are the double acting version of the S pumps.
I S-D pumps are double acting, single air drive head types.
I Cast iron bodies, carbon steel plungers and polyurethane seals.
I All S-D pumps are standard with side inlets only.
I There are two inlets (same side) and two outlets (same side).
I Maximum air drive pressure 145 psi.
I Minimum air drive pressure 15 psi.
I For air control option ... add – ACP to catalog number.
I All S-D pumps come with an unregulated pilot port, 1/8" FNPT, in the top
cap. This feature provides more accurate pressure control and is an ideal
location for control instrumentation.
SERIES
PRESSURES FROM
105 TO 15,000 PSI
AIR
INLET
PRESSURE
RATIO
«
«
PUMP
HEAD
MAXIMUM
OUTLET
PRESSURE
(PSI)
DISPL.
PER
CYCLE
(IN.3)
AIR
CYLINDER
WITH PISTON
CONNECTIONS
INLETS
OUTLETS
S15-D
S25-D
S35-D
S60-D
1:16
1:24
1:38
1:60
2,320
3,480
5,510
8,700
3.45
2.39
1.54
0.98
3/4
1/2
1/2
S100-D
S250-D
1:107
1:250
14,500
15,000
0.55
0.24
1/2
1/2
1/2
3/8
NOTE:
DISCHARGE
SUCTION
TECHNICAL DATA
CATALOG
NUMBER
PILOT
VALVE
1/2
1/2
1/2
1/2
1/2
WEIGHT
(LBS.)
AIR
EXHAUST
MUFFLER
PUMP
HEAD
«
«
32
SPOOL
VALVE ON
SIDE OF
TOP CAP
DISCHARGE
SUCTION
Air drive inlet connection on all S-D pumps is 1/2" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F. Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches)
C
5.31
4.19
3.41
LIQUID
OUTLET
1.00
LIQUID
INLET
AIR INLET
CATALOG
NUMBER
10.25
7.62
LIQUID
INLET
LIQUID
OUTLET
1.00
3/8 – 16
MOUNTING
TAPS (2)
B
2.12
NOTE:
A
A
B
C
S15-D
6.63
3.69
7.88
S25-D, S35-D
6.06
3.00
7.19
S60-D, S100-D, S250-D
7.81
4.06
8.25
Dimensions are subject to change. Consult factory.
FLOW CHART — S-D SERIES
CATALOG
NUMBER
S15-D
S25-D
S35-D
S60-D
S100-D
S250-D
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
60
90
60
90
60
90
60
90
60
90
60
90
OUTLET PRESSURE (PSI)
0
1050
1075
715
730
455
465
285
290
160
165
70
72
500
650
900
575
660
405
440
270
285
153
163
69
71
1000
1500
2000
3000
4000
5000
7500
10000
520
280
530
315
400
240
270
147
157
68
70
340
205
345
210
265
141
154
67
69
90
75
280
160
235
130
150
66
68
90
60
185
110
140
63
67
120
80
126
62
66
40
50
111
60
66
60
50
62
38
56
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 33 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
7
Thi
spr
oducti
s
nol
ongeravai
l
abl
e.
Thi
spr
oducti
s
nol
ongeravai
l
abl
e.
WATER or OIL SERVICE
PP
PP pumps are compact, lightweight and feature rugged construction. They are
SERIES
PRESSURES FROM
60 TO 60,000 PSI
TOP
CAP
SPOOL VALVE ON
SIDE OF TOP CAP
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
«
PUMP
HEAD
«
SUCTION
DISCHARGE
available as single acting with either single, double, or triple air drive heads and
double acting with single air drive head.
I PP4 through PP12 pumps have anodized aluminum bodies and
stainless steel plungers. PP22 through PP189 have stainless steel
bodies and plungers. All PP pumps have polyurethane seals with
Buna-N O-rings standard.
I All PP series pumps are standard with a bottom inlet. For a side
inlet, add – S to the catalog number, for a hand lever, add – HL.
All pumps are side outlet.
I Air drive pressure range is 15 – 145 psi.
I For air control option ... add – ACM to catalog number.
I With the hand lever option, the pump can operate with air or hand lever.
I Multiple air heads increase the effective pressure ratio of the
pump. This provides higher pressure capabilities using less air
pressure to achieve a given outlet pressure.
TECHNICAL DATA
Single Air Drive Head
CATALOG
NUMBER
PP4
PP8
PP12
PP22
PP37
PP72
PP111
PP189
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:4
1:9
1:14
1:28
1:46
1:86
1:130
1:220
580
1,305
2,030
4,060
6,670
12,470
15,000
31,900
DISPL.
PER
CYCLE
(IN.3)
CONNECTIONS
INLET
1.86
0.90
0.57
0.28
0.17
0.09
0.06
0.04
OUTLET
1
1/2
3/4
1/2
3/4
1/2
3/8
1/4
3/8
1/4
3/8
1/4
3/8
1/4
3/8
9/16–18
WEIGHT
(LBS.)
7
Single Air Drive Head with Hand Lever
CATALOG
NUMBER
PP22-HL
PP37-HL
PP72-HL
PP111-HL
PP189-HL
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:28
1:46
1:86
1:130
1:220
4,060
6,670
12,470
15,000
31,900
DISPL.
PER
CYCLE
(IN.3)
0.28
0.17
0.09
0.06
0.04
CONNECTIONS
INLET
OUTLET
3/8
1/4
3/8
1/4
3/8
1/4
3/8
1/4
3/8
9/16–18
WEIGHT
(LBS.)
9
Double Air Drive Head
CATALOG
NUMBER
PP111-2
PP189-2
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:260
1:440
36,250
60,000
DISPL.
PER
CYCLE
(IN.3)
0.06
0.04
CONNECTIONS
INLET
OUTLET
3/8
9/16–18
3/8
9/16–18
WEIGHT
(LBS.)
9
Triple Air Drive Head
CATALOG
NUMBER
PP111-3
PP189-3
NOTE:
10
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:390
1:660
36,250
60,000
DISPL.
PER
CYCLE
(IN.3)
0.06
0.04
CONNECTIONS
INLET
OUTLET
3/8
9/16–18
3/8
9/16–18
Air drive inlet connection on all PP pumps is 1/4" FNPT.
All connections listed are FNPT unless otherwise noted.
The 9 /16" –18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Maximum allowable oil/water temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
WEIGHT
(LBS.)
10
FLOW CHART — PP Series
CATALOG
NUMBER
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
0
500
1500
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
885
905
915
422
430
433
272
275
280
132
136
138
81
83
85
43
44
45
28
29
30
17
17
17
21
21
22
12
12
13
18
19
19
11
11
11
50
50
240
325
160
218
245
110
126
132
74
80
82
42
43
45
27
28
29
15
17
17
20
21
22
12
12
12
18
19
19
11
11
11
53
22
82
105
47
68
75
37
41
43
26
27
28
14
17
17
20
20
21
12
12
12
18
19
19
11
11
11
PP4
PP8
PP12
PP22
PP37
PP72
PP111
PP189
PP111-2
PP189-2
PP111-3
PP189-3
OUTLET PRESSURE (PSI)
3000
5000
7500
10000
3.13
1.941
A
B
C
PP4
2.12
8.50
4.22
PP8
1.88
8.25
3.94
PP12
1.88
8.25
3.94
40000
30
37
56
22
36
39
20
26
27
13
16
16
20
20
21
11
12
12
17
18
19
10
11
11
15
3
24
33
12
22
25
12
15
15
19
19
20
11
12
12
17
18
19
10
11
11
3
21
2
16
21
9
12
14
16
17
19
10
11
12
15
16
17
10
11
11
55000
4
8
16
5
11
13
15
16
18
10
11
12
14
16
18
9
10
11
3
6
11
9
12
16
7
10
11
10
14
17
9
10
11
4
7
1
7
9
5
1
8
13
6
8
10
5
8
5
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
Single, Double and
Triple Air Drive Head
PP22 – PP189
DIMENSIONS (inches)
Single Air Drive Head
CATALOG
NUMBER
25000
Above 35,000 psi
for intermittent
duty only
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION FOR “PP” PUMPS: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
MAXIMUM AIR CONSUMPTION FOR “PP-2” PUMPS: 30 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
MAXIMUM AIR CONSUMPTION FOR “PP-3” PUMPS: 35 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
PP4, PP8, PP12
DIMENSIONS (inches)
15000
CATALOG
NUMBER
3.13
A
PP22 – PP189
2.25
PP111 – 2, – 3
PP189 – 2, – 3
2.94
1.19
0.38
1.941
4.63
4.00
0.38
0.31
0.31
0.63
4.63
4.00
0.62
DOUBLE
AIR
HEAD
(-2)
3.13
9.44
3.13
11.88
8.68
10.00
7.00
7.68
DOUBLE
AIR
HEAD
(-2)
0.75
1.19
AIR
INLET
6.691
LIQUID
OUTLET
7.31
0.75
B
0.19
0.311
DIA.
SINGLE
AIR
HEAD
AIR
INLET
7.06
6.311
4.63
5.31
7.75
C
0.19
9.00
LIQUID
OUTLET
1.941
3.19
SINGLE
AIR
HEAD
LIQUID
INLET
0.311
DIA.
A
A
4.75
NOTE:
1
1.941
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
2.50
LIQUID
INLET
1.56
1.81
4.00
NOTE:
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
11
WATER OR OIL SERVICE
L
L pumps are available as single acting with either a single or
SERIES
PRESSURES FROM
165 TO 60,000 PSI
SPOOL VALVE ON
SIDE OF TOP CAP
TOP
CAP
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
«
PUMP
HEAD
SUCTION
«
DISCHARGE
TYPICAL L10-VE THROUGH
L400-VE PUMPS
SPOOL VALVE ON
SIDE OF TOP CAP
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
«
«
SUCTION
DISCHARGE
TYPICAL L10-2-VE THROUGH
L150-2-VE PUMPS
SPOOL VALVE ON
SIDE OF TOP CAP
AIR
EXHAUST
MUFFLER
DRAIN
PORT
SEPARATION
FITTING
12
«
«
SUCTION
L10-VE
L15-VE
L25-VE
L35-VE
L60-VE
L100-VE
L150-VE
L250-VE*
L300-VE*
L400-VE*
L500-S
DISCHARGE
TYPICAL L250-2-VE THROUGH
L400-2-VE PUMPS
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:11
1:16
1:28
1:40
1:63
1:113
1:151
1:265
1:314
1:398
1:591
1,595
2,320
4,060
5,800
9,135
15,000
21,025
38,425
45,530
57,710
60,000
DISPL.
PER
CYCLE
(IN.3)
CONNECTIONS
(FNPT)
INLET
OUTLET 1
5.49
3.78
2.15
1.49
0.94
0.54
0.40
0.23
0.20
0.15
0.12
1
1
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
WEIGHT
(LBS.)
36
32
1/2
1/2
9/16–18
9/16–18
30
9/16–18
9/16–18
9/16–18
Double Air Drive Head
CATALOG
NUMBER
TOP
CAP
AIR
CYLINDER
WITH
PISTON
PUMP
HEAD
TECHNICAL DATA
Single Air Drive Head
CATALOG
NUMBER
TOP
CAP
PUMP
HEAD
double air drive head and double acting with single air drive head.
I L series pumps have stainless steel bodies and 17-4 plungers.
I All L pumps have UHMWPE (Ultra High Molecular Weight
Polyethylene) seals and Viton2 O-rings (-VE), except as noted.
I L series pumps come standard with a bottom or side inlet.
For side inlet, add – S to catalog number.
I Air drive pressure range is 15 – 145 psi unless limited by
outlet pressure.
I Air drive inlet is 1/2" FNPT.
I For air control option ... add – ACP to catalog number.
I All L pumps come with an unregulated pilot port, 1/8" FNPT,
in the top cap. This feature provides more accurate pressure
control and is an ideal location for control instrumentation.
I All L pumps are available with a double air drive head. This
doubles the pressure ratio of the pump, allowing the use of a
lower ratio base pump, to provide higher flow rates. It is also
used to achieve a given outlet pressure with less air drive
pressure. Add – 2 to the catalog number.
L10-2-VE
L15-2-VE
L25-2-VE
L35-2-VE
L60-2-VE
L100-2-VE*
L150-2-VE*
L250-2-VE*
L300-2-VE*
L400-2-VE*
L500-2-S
NOTE:
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:22
1:32
1:56
1:80
1:126
1:226
1:300
1:530
1:628
1:796
1:1038
3,190
4,640
8,120
11,600
15,000
30,450
42,050
60,000
60,000
60,000
60,000
DISPL.
PER
CYCLE
(IN.3)
CONNECTIONS
(FNPT)
INLET
OUTLET 1
5.49
3.78
2.15
1.49
0.94
0.54
0.40
0.23
0.20
0.15
0.09
1
1
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
WEIGHT
(LBS.)
46
42
1/2
9/16–18
40
9/16–18
9/16–18
9/16–18
9/16–18
9/16–18
L500 pumps have polyurethane seals and Buna-N O-rings and are available side inlet only.
*These pumps have polyethylene seals and Buna-N O-rings.
1The 9 /16" –18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Maximum allowable oil/water temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
2 Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
49
FLOW CHART — L Series
CATALOG
NUMBER
L10-VE
L15-VE
L25-VE
L35-VE
L60-VE
L100-VE
L150-VE
L250-VE
L300-VE
L400-VE
L500-S
L10-2-VE
L15-2-VE
L25-2-VE
L35-2-VE
L60-2-VE
L100-2-VE
L150-2-VE
L250-2-VE
L300-2-VE
L400-2-VE
L500-2-S
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
0
500
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
1100
1125
1150
775
790
800
435
445
450
300
305
310
192
195
200
108
110
113
81
83
84
46
47
48
39
40
41
30
31
32
23
24
24
880
890
900
615
625
630
345
350
355
240
242
245
150
155
157
86
87
89
64
65
66
37
37
37
31
31
31
24
24
25
18
19
19
350
790
915
540
650
705
365
410
425
270
290
300
182
190
195
105
108
110
79
82
83
45
46
47
38
39
40
29
31
32
23
24
24
720
800
840
550
575
600
330
335
345
230
232
235
148
152
154
84
86
88
64
65
66
36
36
37
31
31
31
24
24
25
18
18
19
OUTLET PRESSURE (PSI)
1500
3000
280
60
265
340
150
240
270
145
173
185
97
105
107
76
80
82
44
45
47
37
38
39
29
31
31
22
23
24
95
180
45
130
158
78
95
103
66
75
78
42
44
46
36
38
38
28
30
31
21
23
23
350
570
200
410
500
265
300
320
210
225
230
145
147
152
82
84
86
63
64
65
36
36
36
30
31
31
23
24
25
18
18
18
225
60
208
265
115
190
210
120
136
145
77
82
84
60
62
64
35
36
36
30
30
31
23
24
24
18
18
18
5000
7500
10000
15000
25000
40000
55000
90
43
105
37
78
92
49
67
73
37
43
45
33
37
38
27
30
31
21
23
23
10
47
73
19
53
66
26
40
43
29
35
37
26
29
30
20
22
23
Above 35,000 psi
for intermittent
duty only
5
48
35
55
20
36
41
23
32
36
23
27
29
19
22
23
25
2
26
34
10
26
32
15
24
27
16
20
22
17
8
21
15
22
8
15
19
8
6
13
5
10
21
9
15
150
115
170
70
117
133
72
78
82
57
60
63
35
36
36
29
30
30
23
24
24
18
18
18
95
2
80
112
53
70
77
50
57
61
34
35
36
29
30
30
22
23
24
17
18
18
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION FOR “L” PUMPS: 45 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
MAXIMUM AIR CONSUMPTION FOR “L-2” PUMPS: 80 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
33
82
30
61
72
38
53
58
32
34
35
28
29
30
22
23
23
17
18
18
8
36
57
14
41
51
27
31
34
26
27
29
21
23
23
17
17
18
13
9
32
12
25
30
16
23
27
14
20
22
14
16
17
14
21
5
15
19
11
14
16
2
14
10
16
5
11
14
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
13
WATER OR OIL SERVICE
L
DIMENSIONS (inches)
Single Air Drive Head
SERIES
CATALOG
NUMBER
PRESSURES FROM
165 TO 60,000 PSI
L10-VE
L15-VE
A
AS
B
C
D
E
F
12.19
—
8.25
5.06
6.88
7.81
—
—
8.25
4.38
6.81
7.88
9.68
4.38
L25-VE
L35-VE
11.62
9.75
8.25
3.63
6.88
7.81
3.19
L60-VE
L100-VE
L150-VE
12.13
10.19
8.38
3.44
6.88
7.81
3.81
L250-VE
L300-VE
L400-VE
11.81
10.25
8.38
4.00
6.88
7.81
3.31
L500-S
15.69
—
12.38
4.00
6.88
7.81
—
L10-S-VE*
L15-S-VE*
10.75
1
0.41
DIA.
7.00
0.50
3.121
7.81
AIR
INLET
6.38
5.00
DOUBLE
AIR
HEAD
(-2)
1.00
1.19
0.411
DIA.
1/8" FNPT
PILOT VALVE
1.00
SINGLE
D1 E AIR
HEAD
1.19
Double Air Drive Head
A AS B
LIQUID
OUTLET
1.31
F
3.38
LIQUID
INLET
NOTE:
* Special configuration
C
CATALOG
NUMBER
A
AS
B
C
D
E
F
L10-2-VE
L15-2-VE
16.12
13.63
12.13
3.88
10.81
11.81
4.38
L25-2-VE
L35-2-VE
15.50
13.75
12.13
3.63
10.81
11.81
3.19
L60-2-VE
16.00
14.06
12.38
3.44
10.81
11.81
3.81
L100-2-VE
L150-2-VE
15.50
14.00
12.25
4.00
10.81
11.81
3.81
L250-2-VE
L300-2-VE
L400-2-VE
L500-2-S
19.63
18.13
16.25
2.75
10.81
11.75
3.38
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
L500-S AND L250-2-VE THROUGH L500-2-S
7.00
10.75
6.38
3.121
0.50
7.81
AIR
INLET
1.00
5.00
DOUBLE
AIR
HEAD
(-2)
1.19
1/8" NPT
PILOT
VALVE
1.00
DOUBLE
AIR
HEAD
(-2)
0.50
SINGLE
AIR E
HEAD
B
D1
SINGLE
AIR
HEAD
1.19
AIR
INLET
0.12
AS
A
1.31
OPTIONAL
SIDE
INLET
F
NOTE:
14
0.411
DIA.
LIQUID
OUTLET
C
LIQUID
INLET
3.38
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
L10-VE THROUGH L400-VE AND L10-2-VE THROUGH L150-2-VE
L-D
L-D pumps are double acting versions of the workhorse L series pumps.
I
I
I
I
I
I
I
I
L-D pumps deliver approximately 50% more flow with less pulsation.
All are single air head style, 8 pressure ratios available.
Stainless steel bodies and plunger with UHMWPE (Ultra High
Molecular Weight Polyethylene) seals and Viton2 O-rings (-VE).
L10D – L35D pumps are standard with bottom inlet. For side inlet
add – S.
L60-DS – L250DS pumps are only available with side inlet.
Operating pressure range is 15 – 145 psi.
For air control option add – ACP to the catalog number.
All L-D pumps come with an unregulated pilot port, 1/8" FNPT.
This standard feature allows easy on/off pump control with a very
small valve or pilot switch.
SERIES
PRESSURES FROM
165 TO 38,425 PSI
TOP
CAP
SPOOL
VALVE
ON SIDE OF
TOP CAP
PILOT
VALVE
TECHNICAL DATA
L10D-VE
L15D-VE
L25D-VE
L35D-VE
L60DS-VE
L100DS-VE
L150DS-VE
L250DS-VE
NOTE:
1:10
1:15
1:27
1:40
1:63
1:113
1:151
1:265
1,450
2,175
3,915
5,800
9,135
15,225
21,025
38,425
DISPL.
PER
CYCLE
(IN.3)
10.98
7.56
4.31
2.98
1.92
1.07
0.80
0.46
CONNECTIONS
(FNPT U.N.)
INLET (2) OUTLET (2)
1
1
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
«
EXHAUST
MUFFLER
WEIGHT
(LBS.)
DISCHARGE (2)
SUCTION (2)
48
«
CATALOG
NUMBER
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
PUMP HEAD (2)
42
1/2
1/2
9/16–18
37
9/16–18
Air drive inlet connection on all L-D pumps is 1/2" FNPT.
Air pilot connection is 1/8" and is required for operation.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
The 9 /16" –18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Consult factory for L-D pump dimensions.
2 Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
FLOW CHART — L-D SERIES
CATALOG
NUMBER
L10D-VE
L15D-VE
L25D-VE
L35D-VE
L60D-VE
L100D-VE
L150D-VE
L250D-VE
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
0
500
1000
1500
2000
3000
4000
5000
7500
10000
15000
60
90
60
90
60
90
60
90
60
90
60
90
60
90
60
90
1700
1750
1150
1200
660
680
460
460
300
300
165
165
125
125
70
72
650
1200
775
1000
580
630
420
450
285
290
162
163
123
124
69
71
550
385
540
350
415
260
285
155
161
120
123
68
70
120
220
250
370
230
270
150
160
116
122
67
69
220
140
300
190
250
140
157
113
121
66
68
140
100
200
120
134
103
117
63
67
135
97
132
90
110
62
66
65
120
77
103
60
66
69
32
76
50
62
50
38
56
7
38
OUTLET PRESSURE (PSI)
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 55 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
15
WATER OR OIL SERVICE
GX
GX pumps are high-flow pumps designed for rugged installations and built with
environmental resistant materials. They are ideal for offshore applications with
stainless steel wetted parts and corrosive resistant external components.
SERIES
I
PRESSURES FROM
540 TO 15,225 PSI
AIR
EXHAUST
I
SPOOL
VALVE
I
I
I
I
GX series pumps have stainless steel bodies and plungers,
UHMWPE (Ultra High Molecular Weight Polyethylene) seals
and Viton2 O-rings.
Inlet is in end of head and outlet is on side of head.
Maximum air drive pressure 145 psi.
Minimum air drive pressure 15 psi.
For air control option ... add – ACG to catalog number.
All GX pumps come with a pre-plumbed pilot port.
TECHNICAL DATA
OUTLET
(FARSIDE)
INLET
NOTE:
PRESSURE
RATIO
MAXIMUM
OUTLET
PRESSURE
(PSI)
DISPL.
PER
CYCLE
(IN.3)
1:36
1:66
1:117
1:177
5,220
8,700
15,225
15,225
6.71
3.97
2.20
2.20
AIR CYLINDER
CATALOG
NUMBER
The GX pumps have a pilot port that is pre-plumbed.
This port can be used for control purposes with the
following modifications:
Remove the tube from the front of spool valve housing
to bottom face of end cap.
Remove fitting in spool valve housing and plug with
a 3/8" MNPT plug.
Run your pilot air line to the bottom face connection
using 10 mm tube and fittings.
GX35
GX60
GX100
GX170
NOTE:
23.88
24.50
B
10.63
10.83
C
3.50
4.33
D
4.33
5.51
E
9.69
10.79
F
9.33
9.80
C
GX35
GX60
GX100
GX170
16
3/8
53
3/8
3/8
66
AIR DRIVE INLET
3/4" NPT
F
B
10.811
LIQUID
OUTLET
LIQUID INLET
D
FLOW CHART — GX SERIES
CATALOG
NUMBER
3/8
1
1
1
1
E
NOTE:
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
60
90
60
90
60
90
60
90
WEIGHT
(LBS.)
OUTLET
A
GX35
GX60
GX100 GX170
A
INLET
All connections listed are FNPT unless otherwise noted.
Air drive inlet connection on all GX pumps is 3/4" FNPT.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
2 Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
DIMENSIONS (inches)
CATALOG
NUMBER
CONNECTIONS
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
OUTLET PRESSURE (PSI)
0
1525
1525
850
850
470
470
335
335
500
1400
1450
820
840
465
465
329
332
1000
1100
1360
750
815
460
460
323
330
2000
180
635
570
720
410
455
314
329
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 190 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
3000
4000
5000
7500
150
310
590
360
430
287
319
420
280
390
261
308
180
210
350
232
293
220
153
254
10000
18
183
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
CHEMICAL SERVICE
PPSF
PPSF series pumps are rugged and designed for chemical service
applications. These pumps are available as single acting pumps with single
air drive head and distance piece which provides a separation between the
liquid and air drive sections.
I
I
I
I
I
I
SERIES
PRESSURES FROM
60 TO 14,500 PSI
PPSF pumps have stainless steel bodies and plungers.
PPSF pumps have PTFE seals with Viton2 O-rings.
Pumps come standard with a bottom inlet.
For side inlet add – S.
Maximum air drive pressure is 145 psi. PPSF pumps require
less drive pressure because the pump is driven in both
directions with no spring under the piston. This design reduces
noise and provides less chance of cavitation.
Minimum air drive pressure 15 psi.
For air control option ... add – ACM to PPSF catalog number.
TOP
CAP
SPOOL VALVE
ON SIDE OF
TOP CAP
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
TECHNICAL DATA
PPSF Single Air Drive Head and Distance Piece
PPSF4
PPSF8
PPSF12
PPSF22
PPSF37
PPSF72
PPSF111
NOTE:
1:4
1:9
1:14
1:28
1:46
1:86
1:130
580
1,305
2,030
4,060
6,670
12,470
14,500
DISPL.
PER
CYCLE
(IN.3)
INLET
OUTLET
1.86
0.90
0.57
0.28
0.17
0.09
0.06
1
3/4
3/4
3/8
3/8
3/8
3/8
1/2
CONNECTIONS
DRAIN
PORT
PUMP
HEAD
WEIGHT
(LBS.)
«
DISCHARGE
1/2
15
1/2
SUCTION
1/4
1/4
«
CATALOG
NUMBER
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
8
1/4
1/4
Air drive inlet connection on all PPSF pumps is 1/4" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches)
3.13
0.44
0.19
1.941
4.63
4.00
1.31
0.62
3.13
CATALOG
NUMBER
0.75
AIR
INLET
4.56
5.56
7.881
A
PPSF4
9.81
PPSF8
9.50
PPSF12
9.50
A
DRAIN
0.19
1/8" FNPT
0.311
DIA.
LIQUID
OUTLET
1.941
3.13
LIQUID
INLET
2.00
4.75
NOTE:
2
Viton is a registered trademark of
E.I. DuPont de Nemours & Co., Inc.
NOTE:
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
17
CHEMICAL SERVICE
PPSF
DIMENSIONS (inches) Cont.
0.38
3.13
1.941
4.63
0.38
4.00
SERIES
0.62
PRESSURES FROM
60 TO 14,500 PSI
1.31
3.13
0.75
AIR
INLET
7.13
5.31
6.311
CATALOG
NUMBER
A
B
0.19
7.00
PPSF22
9.81
2.75
PPSF37
9.69
2.69
PPSF72
9.69
2.62
PPSF111
9.69
2.63
A
1/8" FNPT
DRAIN
0.311
DIA.
LIQUID
OUTLET
B
LIQUID
INLET
1.941
1.56
1.81
2.50
4.13
NOTE:
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
FLOW CHART — PPSF Series
CATALOG
NUMBER
PPSF4
PPSF8
PPSF12
PPSF22
PPSF37
PPSF72
PPSF111
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
0
500
1500
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
60
90
120
885
905
915
422
430
433
272
275
280
132
136
138
81
83
85
43
44
45
28
29
30
50
50
240
325
160
218
245
110
126
132
74
80
82
42
43
45
27
28
29
53
22
82
105
47
68
75
37
41
43
26
27
28
OUTLET PRESSURE (PSI)
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
18
3000
5000
7500
15
3
24
33
12
22
25
3
21
2
16
21
10000
14500
30
37
56
22
36
39
20
26
27
4
8
16
3
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
LSF
LSF series pumps are rugged and designed for chemical service
applications. These pumps are available as single acting pumps with single
or double air drive head and distance piece which provides a separation
between the liquid and air drive sections.
I
I
I
I
SPOOL VALVE ON
SIDE OF TOP CAP
TECHNICAL DATA
LSF Single Air Drive Head and Distance Piece
CATALOG
NUMBER
LSF10
LSF15
LSF25
LSF35
LSF60
LSF100
LSF150
LSF250
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
1:11
1:16
1:28
1:40
1:63
1:113
1:151
1:265
1,595
2,320
4,060
5,800
9,135
15,225
21,025
23,200
DISPL.
PER
CYCLE
(IN.3)
INLET
5.49
3.78
2.15
1.49
0.94
0.54
0.40
0.23
1
1
1/2
1/2
1/2
1/2
1/2
1/2
CONNECTIONS
OUTLET
1/2
1/2
1/2
1/2
WEIGHT
(LBS.)
CATALOG
NUMBER
LSF10-2
LSF15-2
LSF25-2
LSF35-2
LSF60-2
LSF100-2
NOTE:
NOTE:
1:20
1:30
1:54
1:78
1:118
1:200
3,190
4,640
8,120
11,600
15,000
23,200
DISPL.
PER
CYCLE
(IN.3)
5.49
3.78
2.15
1.49
0.94
0.54
DRAIN
PORT
42
PUMP
HEAD
«
1/2
1/2
9/16–18
40
SUCTION
9/16–18
DISCHARGE
TYPICAL LSF PUMP
SPOOL VALVE ON
SIDE OF TOP CAP
TOP
CAP
CONNECTIONS
INLET
OUTLET
1
1
1/2
1/2
1/2
1/2
1/2
WEIGHT
(LBS.)
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
1/2
1/2
1/2
1/2
9/16–18
Air drive inlet connection on all LSF pumps is 1/2" FNPT.
Air pilot connection on all LSF pumps is 1/8" FNPT.
All connections are FNPT unless otherwise noted.
The 9/16 – 18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
2
AIR
CYLINDER
WITH
PISTON
AIR
EXHAUST
MUFFLER
44
LSF Double Air Drive Head and Distance Piece
MAXIMUM
OUTLET
PRESSURE PRESSURE
RATIO
(PSI)
TOP
CAP
«
I
PRESSURES FROM
165 TO 23,200 PSI
LSF pumps have stainless steel bodies and plungers.
LSF pumps have PTFE seals with Viton2 O-rings.
Pumps come standard with a bottom inlet.
For side inlet add – S.
Maximum air drive pressure 145 psi.
Minimum air drive pressure 15 psi.
For air control option ... add – ACP to LSF catalog number.
50
DRAIN
PORT
PUMP
HEAD
SUCTION
«
«
I
SERIES
DISCHARGE
TYPICAL LSF-2 PUMP
Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
19
CHEMICAL SERVICE
Single Air Drive Head and Distance Piece
CATALOG
NUMBER
A
AS
B
C
D
DIMENSIONS (inches)
E
0.41
DIA.
F
LSF10–LSF15
16.12
13.63
12.13
5.06
6.88
7.81
4.38
LSF25–LSF35
15.50
13.63
12.13
3.63
6.88
7.81
3.19
LSF60–LSF100
LSF150
16.00
14.06
12.25
3.44
6.88
7.81
3.81
LSF250
15.69
14.13
12.25
4.00
6.88
7.81
3.31
7.00
0.50
10.75
1
3.121
7.81
6.38
5.00
DOUBLE
AIR
HEAD
(-2)
1.00
1.19
1/8" FNPT
PILOT VALVE
0.411
DIA.
1.00
SINGLE
D1 E AIR
HEAD
1.19
Double Air Drive Head and Distance Piece
A AS B
CATALOG
NUMBER
A
AS
B
C
D
E
F
LSF10-2–LSF15-2
20.06
17.56
16.13
5.06
10.81
11.75
4.38
LSF25-2–LSF35-2
19.44
17.56
16.13
3.63
10.81
11.75
3.19
LSF60-2
19.94
18.00
16.25
3.44
10.81
11.75
3.81
LSF100-2
19.94
18.00
16.25
3.44
10.81
11.75
3.31
LIQUID
OUTLET
1.31
F
SAMPLE
AIR DRIVE
PRESSURE
(PSI)
LIQUID
INLET
3.38
FLOW CHART — LSF Series
CATALOG
NUMBER
AIR
INLET
NOTE:
C
1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
OUTLET PRESSURE (PSI)
0
500
1500
3000
5000
60
1100
350
LSF10
90
1125
790
120
1150
915
60
775
540
LSF15
90
790
650
120
800
705
280
60
435
365
60
LSF25
90
445
410
265
120
450
425
340
90
60
300
270
150
LSF35
90
305
290
240
95
120
310
300
270
180
60
192
182
145
45
LSF60
90
195
190
173
130
43
120
200
195
185
158
105
60
108
105
97
78
37
LSF100
90
110
108
105
95
78
120
113
110
107
103
92
60
81
79
76
66
49
LSF150
90
83
82
80
75
67
120
84
83
82
78
73
60
46
45
44
42
37
LSF250
90
47
46
45
44
43
120
48
47
47
46
45
60
880
720
LSF10-2
90
890
800
350
120
900
840
570
60
615
550
200
LSF15-2
90
625
575
410
120
630
600
500
225
60
345
330
265
60
LSF25-2
90
350
335
300
208
15
120
355
345
320
265
150
60
240
230
210
115
LSF35-2
90
242
232
225
190
115
120
245
235
230
210
170
60
150
148
145
120
70
LSF60-2
90
155
152
147
136
117
120
157
154
152
145
133
60
86
84
82
77
72
LSF100-2
90
87
86
84
82
78
120
89
88
86
84
82
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION FOR “LSF” PUMPS: 45 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
20
MAXIMUM AIR CONSUMPTION FOR “LSF-2” PUMPS: 80 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
7500
10000
15000
23200
25
2
26
34
20
10
47
73
19
53
66
26
40
43
5
48
35
55
20
36
41
95
2
80
33
112
82
8
53
30
70
61
36
77
72
57
13
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
ACCESSORIES
High Pressure Relief Valve
PRESSURES FROM 1,000 TO 10,000 PSI
MT10RV
I
I
Gas or liquid
Externally adjustable
TECHNICAL INFORMATION
Materials
I
I
Stainless steel
Can be mounted in line
DIMENSIONS (inches)
Sizing Data
I
Outlet Gland . . . . . .Stainless Steel
I
Orifice . . . . . . . . . . . . . .0.07" DIA.
I
Adjustment
Gland . . . . . . . . . . .Stainless Steel
I
Cv . . . . . . . . . . . . . . . . . . . . . .0.12
I
I
Seat . . . . . . . . . . . . . . . . . . .Nylon
I
I
Seals . . . . . . . . . . . . .PTFE/EPDM
Connections
I
8.13 MAX
3.50 MAX
1.56
2.50
DIA.
1.50 DIA.
Inlet or Thru Ports . . . .1/4" FNPT
Outlet/Vent . . . . . . . . . .1/4" FNPT
(2) PRESSURE PORTS
180° APART - 1/4 FNPT
1.38" DIA. HOLE REQ'D.
FOR PANEL MOUNTING
NOTE:
OUTLET PORT
1/4 FNPT
Dimensions are subject to change. Consult factory.
Pump Cycle Counters
To order: add suffix to pump PN eg. PP012-CCW
I
I
CCP. . . . . Panel mount, 0 – 999,999 max. cycles, 1.03" hg x 2" wd hole
CCW. . . . . Wall mount, 0 – 999,999 max. cycles, 4.00" hg x 2" wd hole
Cycle counters come complete with plumbing to connect to unit. Specify model
of pump or booster when ordering. Cycle counters are air actuated from the
tappet valve exhaust port. Cycle counters are resettable.
Air Control Packages
Consisting of a filter, regulator with gauge, shut-off valve
and required fittings
I
ACM . . . . For all LC, PPO, PP, PP-HL & PPSF pumps, and MPLV air amplifiers
AC . . . . . . For all S pumps
I ACP . . . . . For all L, LO, L-D, S-D, & LSF pumps, DLA & GPLV air amplifers,
and DLE gas boosters
I ACG . . . . . For all GX and GXO pumps
I
Dry Air Spool
For severe duty service
In applications where very dry air or nitrogen is used to drive Maximator pumps
or boosters there is a new spool seal option available to provide longer duty
between maintenance.
This Dry Air Spool (DAS) option should be considered for extreme
operating conditions involving air or gas drive mediums below 0°F. dewpoint,
and similarly, very cold climate applications (-40°C.).
This new design can be retrofitted to existing pumps and boosters as
it only involves the spool, spool sleeve, and seals. The spool block remains the
same. Be sure to use an appropriate tool to pull the spool sleeve! Minimum air
drive with this option is 30 psig.
To order with a pump simply add – DAS to model number. To retrofit
to an existing pump, order “Dry Air Spool” and specify the pump model and
serial number.
21
PORTABLE SYSTEMS
Portable systems are ideal for generating elevated hydraulic or water pressures, using
only shop air, at a variety of locations throughout a facility. They are completely
portable and require only a shop air line to operate if the reservoir option is selected.
A variety of pressure ranges are available to fit your specific requirements,
from low pressures of 1,000 psi to high pressures of 60,000 psi. You may choose
from a number of options to complete the test system best suited for your application.
Power Packs
OIL OR WATER
I
I
Lightweight, portable
Totally self-contained package
ORDERING INFORMATION
MTPP 03
O
Max. Req’d
Pressure
01 1,000 psi
02 2,000 psi
03 3,000 psi
05 5,000 psi
10 10,000 psi
60 60,000 psi
FLOW SCHEMATIC
I
Economical hydraulic power
PPO
1G
G
Service
Pump
Reservoir
Options
O Oil
W Water
PPO, S or LO Oil
PP or L
Water
N
G Outlet gauge
V Vent valve
RD Relief device
None, plate
mounted
1G 1 gallon S.S.
2G 2 gallon S.S.
8G 8 gallon S.S.
1.5G 1.5 gallon
carbon steel
Call to discuss your
specific application.
AIR INLET
-G OPTION
OPTIONAL
PUMP
RESERVOIR
PRESSURE
OUTLET
ABOVE
6,000
PSI
OR BELOW
6,000
PSI
-RD OPTION
-V OPTION
Test Carts
OIL OR WATER
I
I
Hydrostatic testing
Cycle testing
I
I
Hydraulic power
Leak Testing
ORDERING INFORMATION
MTTC 10
O
Max. Req’d
Pressure
FLOW SCHEMATIC
01 1,000 psi
03 3,000 psi
05 5,000 psi
10 10,000 psi
60 60,000 psi
LO
8GP
RD
Service
Pump
Reservoir
Options
O Oil
W Water
PPO, S,
LO or GXO Oil
PP, L or GX Water
N
2G
8GP
ACC Accumulator
DG Dual gauges
DV Directional
control valve
RD Relief device
None
2 gallon S.S.
8 gallon
polyethylene
8GSS 8 gallon S.S.
Call to discuss your
specific application.
-DG OPTION
AIR INLET
WATER
OR OIL
INLET
(NOT USED IF
RESERVOIR OPTION
IS SELECTED)
22
PUMP
-RD OPTION
ACCUMULATOR
PRESSURE
OUTLET
ABOVE
10,000
PSI
OR
8 GAL
RESERVOIR
OPTIONAL
USED ONLY WHEN NO RESERVOIR
BELOW
10,000
PSI
Pump Skids
OIL OR WATER
I
I
Compact, complete packaged systems
Standard powder coated or stainless steel frame
Pump skids are compact systems with most components mounted within the
boundaries of the frame. The systems can be built for water or oil service and have
a control panel to contain all gauges and valves. A variety of pressure ranges and
flows are available, for testing components, ranging from 500 psi to 60,000 psi.
These systems can be supplied with a reservoir or a city water valved inlet.
Reservoirs come with a fill/breather cap, liquid level sight gauge and
drain connection.
ORDERING INFORMATION*
MTPS 05
W
PP72
2G
RD
Pressure
Service
Pump
Reservoir
Options
01
03
05
10
15
20
30
60
O Oil
W Water
PPO, S or LO Oil
PP, L or GX Water
N None
2G 2 gallon S.S.
8G 8 gallon S.S.
ACC Accumulator
DG Dual gauges
DV Directional
control valve
RD Relief device
1,000 psi
3,000 psi
5,000 psi
10,000 psi
15,000 psi
20,000 psi
30,000 psi
60,000 psi
Call to discuss your
specific application.
FLOW SCHEMATIC (See Test Carts)
Test Benches
OIL, WATER, AIR OR GAS
I
I
I Cycle/fatigue testing
Hydrostatic testing
I Leak Testing
Burst testing
MAXPRO test benches are designed for durability, ease of use and accessibility.
These test benches can be equipped for use with oil, water, air, gas or any
combination of test medium. The same test bench could be set up for hydrostatic
testing with water and/or leak testing with gas.
MAXPRO test benches can be provided with manual control or push
button PLC control to handle your specific application.
Test chambers can be included and can be horizontal or vertical. When
specifying a test bench that is to include a test chamber with a windowed door,
please specify the required chamber size.
ORDERING INFORMATION*
MTTB 10
W
G
M
Pressure
05
10
15
20
30
60
5,000 psi
10,000 psi
15,000 psi
20,000 psi
30,000 psi
60,000 psi
Operation
M Manual
R Push button
Service
O Oil
W Water
A Air to 5,000 psi
maximum
G Gas to 21,000 psi
maximum
N None - for second
service
L
N
DLE
Air
Amplifier
GPLV 2:1 amplifier
DLA 5:1 and 15:1
amplifiers
N
None
Liquid Pump
LO Oil pumps
L Water pumps
N None
Gas Booster
RS
Options
RI Remote operating
isolation valve
RS Remote operating
pump shut-off valve
RV Remote operating
vent valve
T Pressure transducer
specify O-10V
or 4-20 ma output
DP Digital pressure
indicator
PI Peak pressure
indicator
DLE Gas booster
N
None
* The photos and ordering information are shown to indicate
capabilities and options. Each system is custom designed
to meet specific operating requirements.
23
OTHER PRODUCTS
Valves, Fittings & Tubing
■
Highest quality for superior product performance
■
Standard metals of stainless steel
■
Pressures to 152,000 PSI
Air Amplifiers & Systems
■
Air driven to 4,350 PSI
■
Deliver increased air pressure to shop
floor equipment and work stations
■
Require no electrical power
■
Single or double acting models
Gas Boosters & Systems
■
Air driven to 21,750 PSI
■
Ideal for gas salvage
■
Units are contaminant free
■
For use with a variety of gases
■
Require no lubrication or electrical power
Repair Service Available
■
Guaranteed quality workmanship
■
Cost effective quick turnaround
■
Use original manufacture parts
■
Factory support
7728 Klier Drive South Fairview, PA 16415
Phone: 814-474-9191 Fax: 814-474-9391
Web Site: www.maxprotech.com
E-mail: [email protected]
■
■
MT MC 3M R8 0308 ©2008 MAXPRO Technologies
All technical and dimensional information subject to change.
All general terms and conditions of sale, including limitations
of our liability, apply to all products and services sold.

Similar documents

m9710/m9730 - Acuity Brands

m9710/m9730 - Acuity Brands lamp number. Most lamps can be supplied. LAMP INCLUDED.

More information