Repair Parts/Beacon Medaes/Area Line Pressure
Transcription
Repair Parts/Beacon Medaes/Area Line Pressure
Repair Parts/Beacon Medaes/Area Line Pressure Alarm Description Part Number 1. 2. 3. 4. 5. Front Panel #98-0221-6804-100 PC Board, Control/Display #98-0631-5010-700 Screw, 6-32 x 3/8,PH. HD.(6) #98-0140-2124-206 GroundingStrap #98-0214-3848-500 Manifold, Gauge (includes flex-hose) #98-0221-5134-800 6. Bracket, Gauge #98-0214-3844-500 7. Coupling, 1/8 NPTF-1/8 NPTF #98-0213-6178-335 8. Nipple, Close, 1/8 NPTM #98-0213-6178-335 9. Line Pressure Gauge - 100 psi #98-0205-8201-300 - 300 psi - 30 in., Hg #98-0205-8373-300 10. Switch Gauge - 100 psi #98-0205-8209-300 - 300 psi #98-0205-8374-300 - 30 in., Hg #98-0205-8210-300 11. Screw, Bracket (2) #98-0140-6127-110 12. Nut, Bracket (2) #98-0144-3127-113 13. Screw (top hole only) #98-0140-6627-108 14. Screw (remaining holes of Grd. Strap) #98-0140-6627-106 15. Harness, Ground Wire (2) #98-0208-6178-700 Not Shown: Teflon Tape Shorting Plug Gauge Cover (louvers) Screw, (2) (for louvers) Cover, Blank Gauge MERCURY MEDICAL® Module Gauge Assembly Part Number Note: A Module Gauge Assembly includes pressure specific gauges and are oriented to fit in either the right or left side of the alarm panel. 100 psi gauges (right module) 100 psi gauges (left module) 300 psi gauges (left module) Vacuum gauges (right module) Vacuum gauges (left module) #98-0221-6906-800 #98-0221-6907-800 #98-0221-6908-800 #98-0221-6909-800 #98-0221-6911-800 All module assemblies include the following standard components: Label, Normal Label Set, Gas Specific Gauge, Line Pressure Switch Gauge Coupling, 1/8 NPTF 1/8 NPTF Bracket, Gauge Assy. Mtg. (2) Tape, Teflon Manifold, Gauge Nipple, Close 1/8 NPTM Screw, Bracket (2) Nut, Bracket (2) #98-0205-4937-300 #98-0205-4948-300 #98-0213-6178-335 #98-0214-3844-500 #69-211-03 #98-0221-5134-800 #98-0413-1000-335 #98-0140-3127-110 #98-0144-3127-113 #98-0220-5050-300 #98-0208-0930-700 #98-0221-6805-100 #98-0140-6124-104 #98-0221-6806-100 Page 308 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Area Line Pressure Alarm Panels ROUGH IN BOX Description 1. Transformer (120V 60Hz) 2. Transformer (220V 50 Hz) (Export only) 3. Support, Circuit Board (5) 4. Screw 5. Lock Washer, #6 lnternal 6. Guard 7. Screw, 6 x 5/16, FL.PH.HD. 8. Cover, U-Channel 9. Audio Alarm 10. Spacer 11. Screw (4) 12. Wire Harness, Low Volt., Al. 13. P.C.-Board, Power Supply 14. Wre Harness, DC Power 15. Socket, Coupling, 1/8” NPTM 16. U-Type Nut 17. Clamp, Cable 5/8” (P clip) MERCURY MEDICAL® Part Number #98-0208-7575-300 #98-0208-7576-300 #98-0602-2602-300 #98-0140-6124-110 #98-0144-1106-131 #98-0214-3865-511 #98-0142-1873-206 #98-0214-3849-510 #98-0221-6892-700 #98-0202-0009-300 #98-0142-1874-206 #98-0608-6133-700 #98-0631-5043-700 #98-0608-6134-700 #98-0221-0156-300 #98-0402-2013-300 #98-0208-0497-300 Page 309 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Ball Valves/Zone Valve Box #98-0207-6225-300 #98-0207-6226-300 #98-0207-6227-300 #98-0207-6228-300 #98-0207-6229-300 #98-0207-6230-300 MERCURY MEDICAL® Page 310 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Ball Valves/Zone Valve Box 989898989898- 98989898- MERCURY MEDICAL® Page 311 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Ball Valves/Zone Valve Box 989898989898- MERCURY MEDICAL® Page 312 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Ball Valves/Zone Valve Box MERCURY MEDICAL® Page 313 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Integrated Alarm Systems II RELAY MODULE COMPONENTS DESCRIPTION 1 Front Cover 2 Label, Point Alarm Set 3 Gas Labels (Others available) Oxygen Medical air Vacuum Nitrogen Nitrous Oxide Evacuation 4 Circuit Board 5 Shunt Connector, .025 x .025 Pins 6 Cable Assembly, Right, Module Bus Cable Assembly, Left, Module Bus 7 Six-Conductor Cable Assembly, Short 8 Cable Assembly, Module Signal 9 Screw, #6, RD, Pan Head 10 Rear Frame, Add-on Module 11 Wall Anchor with Screw 12 Field Input Board 13 Circuit Board Support ITEM NUMBER #98-6801-7010-025 #98-6801-0010-022 #98-6801-0010-009 #98-6801-0010-010 #98-6801-0010-011 #98-6801-0010-012 #98-6801-0010-013 #98-6801-0010-014 #98-6801-3120-004 #98-6812-3010-010 #98-6801-7010-041 #98-6801-7010-042 #98-6801-7010-016 #98-6801-7010-012 #98-0142-2213-204 #98-6801-2510-003 #98-6812-2000-046 #98-6801-7010-004 #98-6801-2020-003 PULSE PRESSURE SENSOR Pulse Pressure Sensor Low Pressure High Pressure Vacuum Line Mounting Bracket MERCURY MEDICAL® (0 - 100 psi or 0 - 690 kPa) (0 - 225 psi or 0 - 1552 kPa) (0 - 30” Hg or 0 - 762 mmHg) Shape Rectangular Rectangular Rectangular Page 314 Stock Number #98-6801-8010-022 #98-6801-8010-023 #98-6801-8010-024 #98-6801-7010-035 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Integrated Alarm Systems II REPAIR PARTS DESCRIPTION 1. Front Cover 2. Gas Labels (Others available upon request) Oxygen Medical air Vacuum Nitrogen Nitrous Oxide Evacuation 3.Unit Labels PSIG in Hg mmHg kPa x 10 4. Circuit Board 5. Shunt Connector ,.025 x .025 Pins 6. Display, Three-Digit LCD 7. Cable Assembly, Right, Module Bus Cable Assembly, Left, Module Bus 8. Six-Conductor Cable Assembly, Short 9. Cable Assembly, Module Signal 10. Screw, #6, RD, Pan Head 11. Rear Frame, Add-On Module 12. Wall Anchor with Screw 13. Field Input Board 14. Circuit Board Supp ITEM NUMBER #98-6801-7010-024 DIGITAL DISPLAY MODULE COMPONENTS #98-6801-0010-009 #98-6801-0010-010 #98-6801-0010-011 #98-6801-0010-012 #98-6801-0010-013 #98-6801-0010-014 #98-6801-0010-023 #98-6801-0010-024 #98-6801-0010-025 #98-6801-0010-026 #98-6801-3120-000 #98-6812-3010-010 #98-6801-3050-003 #98-6801-7010-041 #98-6801-7010-042 #98-6801-7010-016 #98-6801-7010-012 #98-0142-2213-204 #98-6801-2510-003 #98-6812-2000-046 #98-6801-7010-004 #98-6801-2020-003 POINT ALARM MODULE COMPONENTS DESCRIPTION 1. Front Cover 2. Label, Point Alarm Set 3. Gas Labels: (Others available upon request) Oxygen Medical air Vacuum Nitrogen Nitrous Oxide Evacuation 4. Circuit Board 5. Shunt Connector, .025 x .025 Pins 6. LED Light Bar, Red, 8 Segment 7. Cable Assembly, Right, Module Bus Cable Assembly, Left, Module Bus 8. Six-Conductor Cable Assembly Short 9. Cable Assembly, Module Signal 10. Screw, #6, RD, Pan Head 11. Rear Frame, Add-On Module 12. Wall Anchor with Screw 13. Field Input Board 14. Circuit Board Support MERCURY MEDICAL® ITEM NUMBER #98-6801-7010-025 #98-6801-0010-022 #98-6801-0010-009 #98-6801-0010-010 #98-6801-0010-011 #98-6801-0010-012 #98-6801-0010-013 #98-6801-0010-014 #98-6801-3120-001 #98-6812-3010-010 #98-6801-3050-010 #98-6801-7010-041 #98-6801-7010-042 #98-6801-7010-016 #98-6801-7010-012 #98-0142-2213-204 #98-6801-2510-003 #98-6812-2000-046 #98-6801-7010-004 #98-6901-2020-003 Page 315 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Integrated Alarm Systems II ROUGH-IN ASSEMBLY COMPONENTS DESCRIPTION 1. Plaster Shield (not shown) 2. Roughing-In Flanges 3. Power Supply 4. Cover, Power Supply 5. Interconnection Board 6. Six-Conductor Cable Assembly 7. Five-Conductor Cable Assembly 8. Circuit Board Support 9. Ground Harness Wire 10. Fuse, 5 Amp, Ferrule Type 11. Fuse, 2.5 Amp, 250 V, Fast Blow (UL Listed & CSA Approved) 12. Connector Shunt, .025 x .025 13. Tinnerman Nuts 14. Ground Wire Nut, 4-40, Green 15. Washer, Split-Lock #4, SS 16. Screw, #4-40 x 0.5”, Phillips, PH 17. Screw, #6-32 x 1/4”, Pan Head 18. Screw, #6 x 1/4”, Type AB, Slotted Hex Head 19. Screw, #6 x 1/4”, Type AB, Slotted Hex Head ITEM NUMBER #98-6801-2180-009 #98-6801-2530-008 #98-6801-3060-003 #98-6801-2530-017 #98-6801-3120-005 #98-6801-7010-017 #98-6801-7010-040 #98-6801-2020-003 #98-6801-7010-020 #98-6812-3290-009 Obtain Locally #98-6812-3010-010 #98-0402-2004-300 #98-6812-2010-007 #98-6812-2020-004 #98-6812-2000-011 #98-0140-6124-104 #98-6812-2000-044 #98-6812-2000-044 CENTRAL MODULE COMPONENTS DESCRIPTION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. MERCURY MEDICAL® Page 316 Front Cover End Cap LED Light Bar, Green LED Light Bar, Red LED Light Bar, Yellow Alphanumeric Display System Program EEPROM Customer Specific EEPROM Circuit Board 26-Conductor Ribbon Cable Nine-Wire Power Cable Connector Shunt, .025 x .025 pins Hinge Pin Rear Frame, Central Module Label, Caution (not shown) Screw, #6-32 x 1-1/4” Screw, #6, RD, Pan Head Screw, #2-56 x 5/8,” Pan Head Nut, #2-56, Hex Washer, #2, Plain Spacer, 3/8” Long, .12” ID, .25” OD ITEM NUMBER #98-6801-7010-047 #98-6801-2510-005 #98-6801-3050-005 #98-6801-3050-004 #98-6801-3050-006 #98-6801-7010-003 #98-6801-7010-045 #98-6801-7010-044 #98-6801-3120-002 #98-6801-7010-030 #98-6801-7010-018 #98-6812-3010-010 #98-6801-2560-000 #98-6801-2510-001 #98-6801-0010-027 #98-0140-6424-120 #98-0142-2213-204 #98-6812-2000-045 #98-6812-2010-009 #98-6812-2020-019 #98-6812-2020-020 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Med Plus Alarm Panel Annunciator Module Less Module #98-6818-8180-002 Area Display Module Less Labels #98-6818-8180-010 Master Alarm Module Less Labels #98-6818-8180-007 System Power Supply #98-6818-3000-003 To Order, add the Prefix “98” to each Part Number. Pressure Sensors Vacuum 0-50 psi Gases O2, Medical air, N2O, CO2 Nitrogen MERCURY MEDICAL® #98-6818-8180-005 #98-6818-8180-004 #98-6818-8180-003 Page 317 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Multi-Signal Alarms Description 1. Control Board 2. Screw 6-32 X 1/4 3. Bracket 4. Spacer, Long 5. Spacer, Short 6. Screw, 6-.32 X 1-5/8 7. Guard, Bracket 8. Supply Board 9. Alarm Horn 6-28 Vdc (Sonalert) 10. Harness, Wire 11. Bracket, Light Box 12. Switch, Push Button 13. Cover Plate, Module 14. Connector Housing 15. Lamp Socket, 28 V 16. Lens, Indicator (red) 17. Lamp, 28V 18. Label, Abnormal legend 19. Housing, lamp (round/green) 20. Connector, P. C. Board 21. Nut, Tinnerman Speed 22. Finish Screw Item Number #98-0208-6076-300 #98-0140-6124-104 #98-0214-3851-511 #98-0202-0006-300 #98-0202-0005-300 #98-0140-6124-126 #98-0214-3869-711 #98-0208-6075-300 #98-0208-0381-300 #98-0208-6085-700 #98-0214-3850-511 #98-0208-5103-300* #98-0221-6825-300 #98-0208-2052-300 #98-0208-0585-300 #98-0208-0586-300 #98-0208-0587-300 #98-0205-4305-300 #98-0208-0584-300* #98-0208-2082-300 #98-0402-2004-300 #98-0400-1056-300 Add-On Modular Components Description 1. Insulator, Lamp House & P.C. Board 2. Wire Harness 3. Control Boards 4. Screw, 6-32 X 1/4 5. Screw, 6-32 X 3/16 6. Bracket, 9 pin Mate-N-Lok 7. Connector Housing 8. Lamp Socket, 28V 9. Lens Indicator 10. Lamp, 28V 11. Cover Plate, Add-On Module 12. Connector, P.C. Board 13. Label, Abnormal legends (supplied with “A Module) 14. Finish Screw Note: Part numbers which are followed by an asterisk (*) are not field replaceable. In the event of a malfunction of one of these parts, the entire unit should be returned for servicing. MERCURY MEDICAL® Page 318 Item Number #98-0210-8029-300 #98-0208-6087-700 #98-0208-6076-300 #98-0140-6124-104 #98-0140-9124-103 #98-0214-3861-511 #98-0208-2052-300 #98-0208-0585-300 #98-0208-0586-300 #98-0208-0587-300 #98-0221-6826-300 #98-0208-2082-300 #98-0205-4305-300 #98-0400-1056-300 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Multi-Signal Alarms Description 1. Alarm Interface cabinet, less mtg. panel 2. Panel, unassembled 3. Washer, 3/8” (4) 4. Hex nut, 3/8” - 16 (4) 5. Spacer, Nylon (12) 6. Screw, 6-32 X 7/8’ (12) 7. Wire harness (2) 8. Terminal Strip (6 position) 9. Circuit Board assembly (3) 10. Terminal Strip (15 position) 11. Relay only (coil voltage 24V) Item Number #98-0208-0452-400 #98-0214-3857-500** #98-0402-0731-300 #98-0144-3345-113 #98-0202-0009-300 #98-0140-6124-114 #98-0208-6109-700 #98-0690-2700-316 #98-0208-6081-700 #98-0690-2700-371 #98-0690-2350-311* 12. Transformer Assembly Transformer only (120V/28.5V) 13. Nut, Elas. 6-32 (2) 14. Screw, 6-32 X 1/4 (4) 15. Bracket, Transformer 16. Screw, 6-32 X 7/16 (2) 17.Terminal Strip (3 term) #98-0208-7574-700 #98-0208-7513-300 #98-0202-1019-300 #98-0140-6624-104 #98-0214-3852-500 #98-0140-6624-107 #98-0208-2100-300 Note: Part numbers which are followed by an asterisk (*) are not field replaceable. In the event of a malfunction of one of these parts, the entire unit should be returned for servicing. Description 1. Nut,Tinnerman type U 2. Plate, Instruction 3. Screw, #6 X 5/16 4. Guard 5. Transformer 12OV/28.5 22OV/28.5 (Export model) 6. Bracket, 9 pin Mate-N-Lok 7. Harness wire with terminal on spacers 8. Marker, wire 1-5 and ground 9. Marker, “A” 10. Harness.wire with terminal block without spacers 11. Marker, “B” 12. Marker, “C” 13. Marker, wire A1-A5/B1-B5/C1-C5. Part Number #98-0402-2013-300 #98-0205-4320-300 #98-0142-2843-205 #98-0214-3865-511 #98-0208-7513-300 #98-0208-7570-300 #98-0214-3861-511 #98-0208-6086-700 #98-0208-2960-300 #98-0208-2970-300 #98-0208-6088-700 #98-0208-2971-300 #98-0208-2972-300 #98-0208-2961-300 1. Spacer (for wire harness) 208-6086-700 only) #98-0202-0009-300 2. Terminal Strip #98-0208-2110-300 3. Nut, Tinnerman Speed #98-0402-2004-300 4. Screw, 6-32 X 1/4 #98-0140-6624-104 5. Insulator Transformer #98-0210-8074-300 6. Bracket, Transformer #98-0214-3852-500 MERCURY MEDICAL® Page 319 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Puritan Bennett Series B Outlets for D.I.S.S. and Puritan Bennett Type Quick Connect ITEM PART NUMBER 11. 11A. (Standard) (Update) #06-230930 #06-231830 #06-230931 #06-231831 #06-230932 #06-231832 #06-230933 #06-231833 #06-230935 #06-231835 #06-230937 #06-231837 #06-230938 #06-231838 #06-230939 #06-231839 12. #06-811151-PG 13. #06-621501-PG 14. #06-814663-PG 15. #06-415102 16. #06-525220 16A. #06-525248 17. #06-230370-PG #06-230078-PG 17A. 18. 19. #06-290477-PG #06-290478-PG #06-290099 #06-230910 #06-230911 MERCURY MEDICAL® DESCRIPTION ITEM PART NUMBER Puritan-Bennett Quick-Connect Latch Valve Assembly Latch Valve Assembly (For update to Series B) includes items 12 through 15, 16A, 17A & 18. #06-230912 #06-230913 #06-230914 #06-230915 #06-230917 #06-230918 #06-230919 #06-230920 #06-230921 #06-230922 #06-230923 #06-230924 MEDICAL AIR (U.S. Labeling) VACUUM (U.S. Labeling) NITROGEN (U.S. & Int’l Labeling) OXYGEN (Int’l Labeling) MEDICAL AIR (Int’l Labeling) VACUUM (Int’l Labeling) WAGD (EVACUATION) (Int’l Labeling) CARBON DIOXIDE (U.S. & Int’l Labeling) CO2/O2 Mixture (CO2 over 7.5%) O2/CO2 Mixture (CO2 not over 7.5%) He/O2 Mixture (He over 80.5%) O2/He Mixture (He not over 80.5%) 20. #06-622537-PG #06-622036-PG #06-622501-PG #06-622536-PG #06-622538-PG #06-622539-PG #06-622508-PG #06-622012-PG 21. #06-835505-PG 22. #06-290458-PG 23. #06-622012-PG 24. #06-525223 #06-525224 #06-525225 25. #06-325149 25A. #06-325148 26. #06-827530-PG O-Ring (Pkg of 10) MEDICAL AIR VACUUM NITROGEN CO2, CO2/O2 MIX, HE/O2 MIX O2/CO2 MIX WAGD (EVACUATION) O2/He Mix N2O OXYGEN (U.S. Labeling) NITROUS OXIDE (U.S. & Int’l Labeling) MEDICAL AIR (U.S. Labeling) VACUUM (U.S. Labeling) OXYGEN (Int’l Labeling) MEDICAL AIR (Int’l Labeling) VACUUM (Int’l Labeling) WAGD (EVACUATION) (U.S. Labeling) Mounting Screw (2 Required) (pkg of 10) Retaining Washer (2 Required) (Pkg of 10) Screw (2 Required) (Pkg of 10) Connector Retainer Connector Connector (Valve Upgrades) Spring and Poppet Kit Vacuum (Pkg of 10) Pressure (Pkg of 10) Spring and Poppet Kit Vacuum (Pkg of 10) Pressure (Pkg of 10) Seal (Pkg of 25) Diameter Index Safety System Valve Assembly (Includes items 12, 13 & 20 -24) Oxygen (U.S. labeling) Nitrous Oxide (U.S. & Int’l Labeling) Page 320 DESCRIPTION Retaining Ring (Pkg of 10) Spring and Poppet Kit D.I.S.S. Pressure, Vacuum, and Evac. (Includes Item 23) (Pkg of 10) O-Ring (Pkg of 10) VALVE STEM OXYGEN OTHER GASES VACUUM COVERPLATE (5” Center Spacing) COVERPLATE (3 1/4” Center Spacing) JAM NUT (2 Required) (Pkg of 10) (Used for console installation) (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Puritan Bennett For Beacon Medical (Formerly Puritan-Bennett) ITEM PART NUMBER 1. DESCRIPTION Concealed Rough-In Assembly (Includes items 2 through 10) Console Rough-In Assembly (Includes items 2 through 10) Console Rough-In Assembly with Hose Barb Connector (Includes items 2, 5 through 10) 1A. 1B. (Concealed) (Console) #06-230860 #06-230855 #06-230861 #06-230856 #06-230862 #06-230857 #06-230863 #06-230858 #06-230864 #06-230859 #06-230865 #06-230845 #06-230867 #06-230847 #06-230868 #06-230848 #06-230869 #06-230849 #06-230870 #06-230840 #06-230871 #06-230872 #06-230842 #06-230873 #06-230874 All Series B Rough In Assemblies ITEM 2. (Console) #06-230884 #06-230885 #06-230886 #06-230887 OXYGEN (U.S. Labeling) NITROUS OXIDE (U.S.& Int’l Labeling) MEDICAL AIR (U.S. Labeling) VACUUM (U.S. Labeling) NITROGEN (U.S. & Int’l Labeling) #06-230892 OXYGEN (Int’l Labeling) 3. MEDICAL AIR (Int’l Labeling) 4. VACUUM (Int’l Labeling) 5. WAGD (EVAC.) (U.S. Labeling) 6. CARBON DIOXIDE (U.S. Labeling) 7. CO2/O2 MIXTURE (CO2 over 7.5%) 8. O2/CO2 MIXTURE (CO2 not over 7.5%) 9. He/O2 MIXTURE (He over 80.5%) O2/He MIXTURE (He not over 80.5%) 10. MERCURY MEDICAL® Page 321 PART NUMBER DESCRIPTION GAS IDENTIFICATION LABEL (Sheet of 20) #06-435393 OXYGEN (U.S. Labeling) #06-435399 NITROUS OXIDE (U.S. & Int’l Labeling) #06-435395 MEDICAL AIR (U.S. Labeling) #06-435397 VACUUM (U.S. Labeling) #06-435400 NITROGEN (U.S. & Int’l Labeling) #06-435394 OXYGEN (International Labeling) #06-435396 MEDICAL AIR (International Labeling) #06-435398 VACUUM (International Labeling) #06-435402 WAGD (EVACUATION) (U.S. Labeling) #06-435401 CARBON DIOXIDE (U.S. & Int’l Labeling) #06-435406 CO2/O2 MIXTURE (CO2 over 7.5%) #06-435407 O2/CO2 MIXTURE (CO2 not over 7.5%) #06-435404 He/O2 MIXTURE (He over 80.5%) #06-435405 O2/He MIXTURE (He not over 80.5%) #06-826003-PG Speed Nut (2 Required, Pkg of 10) #06-811665-PG Screw (2 Required, Pkg of 10) #06-836828-PG Plug (Vacuum outlets only, pkg of 10) #06-835900-PG Retaining Ring (Pkg of 10) #06-415037-PG Washer (Pkg of 10) #06-655028-PG Seal (Pkg of 10) #06-616272-PG Secondary Check Valve (Pkg of 10) #06-833426-PG Spring (Pkg of 10) (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Beacon Medaes/Puritan Bennett SERIES B OUTLETS FOR D.I.S.S. and OHMEDA TYPE QUICK CONNECT Part Number 11. 12. 13. 14. 15. 16. Description OHMEDA QUICK -CONNECT LATCH VALVE ASSEMBLY (Includes items 12 through 25) #06-230940 #06-230941 #06-230942 #06-230943 #06-230945 #06-230947 #06-230948 #06-230949 #06-811151-PG #06-621501-PG #06-815303-PG #06-415101 #06-835505-PG 17. #06-290458-PG 18. 19. 20. 21. 22. 23. 24. 25. #06-622012-PG #06-833430 #06-616275 #06-622570-PG #06-415038 #06-833953 #06-525222 MERCURY MEDICAL® OXYGEN (U.S. Labeling) NITROUS OXIDE (U.S. & Int’l Labeling) MEDICAL AIR (U.S. Labeling) VACUUM (U.S. Labeling) OXYGEN (Int’l Labeling) MEDICAL AIR (Int’l Labeling) VACUUM (Int’l Labeling) WAGD (EVACUATION) (U.S. Labeling) Mounting Screw (3 Required) (pkg of 10) Retaining Washer (Pkg of 10) Screw (4 Required) (Pkg of 10) Back Plate Retaining Ring (pkg of 10) Spring and Poppet Kit (Includes Item 18) Ohmeda Vac and Evac (Pkg of 10) O-Ring (Pkg of 10) Dust Seal Spring Dust Seal O-Ring (Pkg Of 10) Washer Spring Connector Diameter Index Safety System Valve Assembly (Includes Items 14, 17 and 26 thru 29) Part Number Description #06-230910 #06-230911 #06-230912 #06-230913 #06-230914 #06-230915 #06-230917 #06-230918 #06-230919 #06-230920 #06-230921 #06-230922 #06-230923 #06-230924 OXYGEN (U.S. Labeling) NITROUS OXIDE (U.S. & Int’l Labeling) MEDICAL AIR (U.S. Labeling) VACUUM (U.S. Labeling) NITROGEN (U.S. & Int’l Labeling) OXYGEN (Int’l Labeling) MEDICAL AIR (Int’l Labeling) VACUUM (Int’l Labeling) WAGD (EVACUATION) (U.S. Labeling) CARBON DIOXIDE (U.S. & Int’l Labeling) CO2/O2 MIXTURE (CO2 over 7.5%) O2/CO2 MIXTURE (CO2 not over 7.5%) He/O2 Mixture (He over 80.5%) O2/He Mixture (He not over 80.5%) 26. #06-622537-PG #06-622036-PG #06-622501-PG #06-622536-PG #06-622538-PG #06-622508-PG 27. 28. 28A. 29. Page 322 #06-525223 #06-252224 #06-525225 #06-325149 #06-325148 #06-827530-PG O-RING SEAL (Pkg of 10) MEDICAL AIR VACUUM NITROGEN CO2, CO2/O2 MIX, HE/O2 MIX O2/CO2 MIX O2/He MIX VALVE STEM OXYGEN OTHER GASES VACUUM Coverplate (5” Center Spacing) Coverplate (3 1/4” Center Spacing) Jam Nut (2 Required) (Pkg of 10) (Used for console installation) (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Ohmeda Medaes/Nitrogen Control Panels DESCRIPTION PART # 1. Panel 2, Label: Nitrogen Label: Medical Air 3. Panel Screws 6-32 x 1 1/2 4, Check Units: Nitrogen Check Units: Medical air 5. Washer 6, Knob-Regulator 7. Valve-Supply 8. Washer 9. Gauge 0-300 psi #98-6812-2000-847 #98-6804-0010-045 #98-6804-0010-046 #98-0140-6224-124 #98-6800-1000-181 #98-5804-0013-000 #98-6812-2000-660 #98-6812-2000-867 #98-6804-2080-018 #98-6812-2000-660 #98-6804-2070-008 DESCRIPTION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. MERCURY MEDICAL® Page 323 PART # Elbow 1/4 NPT x 3/8” tube Street Tee 1/4 NPT Regulator Connector 1/4 NPT x 3/8” tube Tee 1/4 NPT Washer Plain Washer Lock Connector 1/4 NPT x 1/8” tube Tubing 1/8” OD Connector 1/8 NPT x 1/8” tube St. Elbow 1/4 x 1/8 NPT Nut Tubing 3/8” OD Insert (800) 835-MMED (727) 573-0088 #98-6804-2060-051 #98-6812-2060-022 #98-6804-2090-016 #98-6804-2060-010 #98-6812-2000-127 #98-6812-2000-661 #98-6812-2000-662 #98-6812-2060-007 #98-6812-2140-000 #98-6812-2060-008 #98-0413-3060-300 #98-6804-2060-052 #98-6804-2140-023 #98-6804-2060-048 FAX (800) 990-6375 Repair Parts/Resuscitators/Puritan-Bennett 1 2 3 4 5 7 8 9 MERCURY MEDICAL® Page 324 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Sphygmomanometers Tycos Repair Components NUMBER #20-5085-01 DESCRIPTION Leather Carrying Case #20-5087-03 Valve Thumb Screw for Hand Model 1 (pre 1979) Valve Assembly for Hand Model 1 (pre 1979) Valve Assembly for Hand Model 1 (after January 1, 1979) Valve Thumb Screw for Hand Model 1 (after January 1, 1979) #20-5087-04 #20-5087-08 #20-5087-09 STD. PACK 1 #20-5089-09 Plastic Y Adapter 1 #20-5089-11 Metal Twist Fit Connectors Set 1 #20-5089-12 Tubing 27” Length 1 #20-5089-13 #20-5089-23 Coil Tubing. 8’ Length* Coil Tubing, Conductive* 1 1 #20-5090-44 Front Ring Bezel for Aneroid 1 #20-5090-45 Shatterproof Crystal for Aneroid** 1 #20-5090-29 Bulb End Valve 1 #20-5090-30 Screen Assembly 1 #20-5090-64 Clip Assembly for Pocket Aneroid** 1 #20-5091-15 Crystal for Wall Gauge. Circular 1 #20-5091-16 1 #20-7670-08 Crystal for Wall Classic Gauge, Square Crystal for 767 Wall Aneroid 1 #20-5091-33 Cuff Clip 1 #20-5097-14 Vertical Tube, Wall Mercurial 1 #20-5097-15 Filter and Gasket Set for Mercurial Gauge 1 #20-5097-16 Tube Cap, Mercurial 1 #20-5097-17 Bracket Assembly for Wall Mercurial 1 #20-5097-25 Incline Tube, Mobile Mercurial 1 #20-5097-32 1 #20-5098-07 Vertical Tube Wall Mercurial (marked 4.2 mm) Incline Tube, Mobile Mercurial (marked 4.2 mm) Luer Lock (set) #20-5098-17 Housing Screws for Hand Gauge #20-5097-33 1 1 12 *#20-5089-11 Twist Fit Connectors are included with coil tubing. **New Classic Charcoal Sphygmomanometers only. MERCURY MEDICAL® Page 325 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Western Medica/Suction/Accessories SUCTION INTERRUPTER SUCTION CAP ASSEMBLY 13 1. 2. 3. 4. 5. 6. 7. 7A. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. #34-VR2014 #34-M22-2 #34-M00-5 #69-20225 #69-20234 #69-20541 #34-MG-70 #34-MGL-70 #69-20702 #34-VR3507 #34-VR3506 #34-VR3505 #34-VR3504-1 #34-2002-1 #34-VR3503 #34-VR3502 #34-RO-011E #34-VR2011 MERCURY MEDICAL® Nipple, Vacuum D.I.S.S. NUT Clip Tee 1/8 x 1/8 x 1/8 NPT Adaptor Pipe Nipple Gauge Replacement Lens 45° Bushing Interruptor Body Washer Interruptor Sleeve Piston Weight “95” Ball Washer Interruptor Cap O-Ring Orifice Set Screw 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13a. 13b. 14. 15. 16. #69-20223 Nipple, D.I.S.S.Vacuum x 1/8 NPT Male #34-M22-2 Nut #69-30300 Retainer Clip #34-VR3000 Suc. Reg. Lock Stem #34-VR3001 CU Washer (2 required) #34-VR3002 Cap #34-VR3003 Center Plate #34-VR3004 Gasket, Bottle Cap #34-VR3005 Cage Housing, Spring #34-VR3006 Spring Ball Retainer #34-VR3007 Suction Cup #34-VR3008 Ball Float #34-VR3015-1 w/Tube Stem Ass’y #34-VR3015-2 w/D.I.S.S. 1220 Stem Ass’y #34-VR3012 Locking Nut #69-20589 O-Ring 10 (10/Pkg) #34-VR3302 Replacement 1/2 gallon bottle, not shown #34-VR3203 Replacement quart bottle, not shown #34-VR3102 Replacement pint bottle, not shown Page 326 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375 Repair Parts/Zone Valve Description Mounting Strap (Not Shown, For Field Ganging Boxes Only) Window Pull Ring Assembly (All Sizes) Pressure Gauge 0-100 PSI (O2, N2O, Air, Co2) Vacuum Gauge 0-30 Inch. (Vac or WAGD) Pressure Gauge 0-300 PSI (Nitrogen) Service Identification Label package Ball Valve Adapter Plug Blank 11/4” Up Ball Valve Adapter Plug Blank Up to 1” Frame Mounting Screw (8) Kit Legend Strip Mounting Screw (4) Kit Mounting Extension Screw (6) Kit Trim Flange (For Gauge) (3) Kit MERCURY MEDICAL® Catalog Number 32-77900451 32-77900439 32-77900571 32-77900572 32-77900573 32-77900449 32-77900461 32-77900462 32-77900411 32-77900412 32-77900413 32-77900414 Page 327 (800) 835-MMED (727) 573-0088 FAX (800) 990-6375
Similar documents
Observing coastal and inland waters with Landsat-8
- two atmospheric correction schemes were developed at RBINS, using the red+NIR band (VR2014) and the SWIR bands (VR2015).
More information