AECO CATALOGUE - z
NAMUR INDUCTIVE SENSORS CYLINDRICAL HOUSING Ø 6.5 - M8-M12-M14-M18-M30 2 WIRES D.C. - VERSION N EMBEDDABLE (FLUSH MOUNTING) NOT EMBEDDABLE Ø 6,5 M8 x 1 M8 x 1 M12 x 1 M12 x 1 2,5 2,5 4 Ø 6,5 41 41 30 30 30 30 28 28 (NON FLUSH MOUNTING) TECHNICAL CHARACTERISTICS Dimensions mm MODELS WITH CABLE SI 6.5 - N1 SI 6.5 - NE2 MODELS WITH CONNECTOR SI 6.5 - N1 H1 SI 6.5 - NE2 H1 SI 8 - N1 H1 SI 8 - NE2 H1 SI 12 - N2 H SI 12 - NE4 H 1 2 mA 28 45 2 4 In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 2000 2000 % of Sn Repeatability 45 44 44 2 8,2 ("5 ÷ 30" see note 1) Hz Switching frequency 28 28 39 1 Continuous voltage (residual ripple ≤10%) V Absorption current at 8.2V SI 12 - NE4 28 2,5 30 39 30 mm Switching distance (Sn) SI 12 - N2 4 SI 8 - NE2 2,5 SI 8 - N1 2000 ≤3 Temperature limits °C -25 ÷ +70 Degree of protection IP 67 (With H1 - H depending on connector) Nickelled brass Housing 2m Cable PUR blue 2 x 0.25 mm2 2 x 0.25 mm2 Connector plug H1 2 x 0.25 mm2 H1 H NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - WORKING PRINCIPLE Metallic plate Current (mA) In presence of metal I ≤ 1 mA 1 KΩ 3 + 8.2Vdc -2 In absence of metal I ≤ 3 mA 1,3 1 1 KΩ + 8.2Vdc -- Distance Sn (mm) 6 The NAMUR sensors are electronic devices whose absorbed current varies in the presence of a metallic object. The difference between these sensors and traditional sensors is the absence of amplifier trigger stages. Note 1: In applications outside security conditions the sensors can be used in the 5-30Vdc range. ® Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected] ® NAMUR INDUCTIVE SENSORS M14 x 1 M18 x 1 M18 x 1 M30 x 1.5 M30 x 1.5 43 47 43 27 27 28 47 36 30 36 30 28 4 15 7,5 M14 x 1 SI 14 - NE5 SI 18 - N5 SI 18 - NE8 SI 30 - N10 SI 30 - NE15 - - SI 18 - N5 H SI 18 - NE8 H SI 30 - N10 H SI 30 - NE15 H 3 5 5 8 10 15 27 51 51 51 51 28 28 27 7,5 15 SI 14 - N3 8,2 ("5 ÷ 30" see note 1 at page 6) In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 1000 2000 500 ≤3 -25 ÷ +70 67 (With H depending on connector) Nickelled brass 2 x 0.50 mm2 2 x 0.25 mm2 Non previsto H 2 x 0.50 mm2 H - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - APPLICATIONS The NAMUR (DIN 19234) proximity switches are electronic sensors whose absorbed current varies in the presence of metallic objects. The reduced dimensions, the low values of voltage, current and impedance (unaffected by overvoltage and excessive current from inductive or capacitive sources), allows them to be used in various applications in both intrinsically safe and normal areas. Applications in intrinsically safe areas (explosive atmospheres). * The sensor must be used with an intrinsically safe relay or an equivalent static input suitable for intrinsically safe applications. Standard applications (normal atmospheres). The sensor must be used with AECO supply and amplifier units ALNC, ALN2 or similar. * When ordering, add “Ex” (Es. SI8-N1 Ex). 7 Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected] INDUCTIVE CONFORMING TO NAMUR STANDARDS (DIN 19234) APPROVAL EEx ia IIc T4* NAMUR INDUCTIVE SENSORS RECTANGULAR HOUSING SIPA8 - SIPC8 - SIP10 - SIP12 - SIP17 - SIP40 - SIQ80 2 WIRES D.C. - VERSION N Sensing surface Sensing surface 3 (NON FLUSH MOUNTING) Sensing surface 8x8 3 8x8 10 5 4,6 20 10 M3 3,3 Sensing surface 3 Sensing surface 4,6 9 9 9 SIP 10 - N2 H1 1.5 2 In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 2000 2000 % of Sn 1000 ≤3 Temperature limits °C -25 ÷ +70 Degree of protection IP 67 (With H1 depending on connector) Anodized aluminium Plastic 2 x 0.25 mm2 2 x 0.25 mm2 2 x 0.25 mm2 H1 H1 H1 Housing 2m Cable PUR blue 10,5 8,2 ("5 ÷ 30" see note 1 at page 6) Hz Repeatability 49 10 10 SIP C8 - N1.5 H1 1.5 mA Switching frequency 40 49 M3 20 40 40 M3 20 40 SIP A8 - N1.5 H1 Continuous voltage (residual ripple ≤10%) V Absorption current at 8.2V Sensing surface 16 10,3 = = 8x8 10 Sensing surface mm Switching distance (Sn) Sensing surface 3 8x8 10 MODELS WITH CONNECTOR SIP 10 - N2 17,9÷19,4 Sensing surface SIP C8 - N1.5 22,2 = 28 = SIP A8 - N1.5 16 10 Dimensions mm MODELS WITH CABLE 17,9÷19,4 20 40 M3 20 40 TECHNICAL CHARACTERISTICS 10,5 20 10 16 10,3 = = 22,2 = 28 = EMBEDDABLE (FLUSH MOUNTING) NOT EMBEDDABLE Connector plug NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - WIRING DIAGRAMS WITH CABLE OR TERMINAL BLOCK CONNECTION WITH H1 - H - K PLUG ADJUSTABLE SENSITIVITY SIP 40 FOR THE CONNECTORS SEE PAGE 85 1 4 Brown + 1 3 -- VIEW OF MALE CONNECTOR H1 1 = Brown / + 3 = Blue / _ 5 4 2 3 4 Blue 2 + 1 1 -- 3 VIEW OF MALE CONNECTOR H 1 = Brown / + 3 = Blue / _ 2 N.B.: On request is available cable for sensors with different length 3.5 - 7.5 - 5 - 10 metres. 8 1 2 VIEW OF MALE CONNECTOR K 1 = Blue / _ 2 = Brown / + NOTE: In the SIP 40 sensor the oscillator is contained in a module which clips into the body whose surface can then be sensitive on five different positions. The surface chosen can be identified by applying the circular adhesive label. ® Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected] ® NAMUR INDUCTIVE SENSORS Sensing surface 26 18 Ø 3,8 Sensing surface 113 17 x 17 = = 80 28 Ø 3,2 60 3 M3 = = 10,5 = = 44,5 50 65 = 40 30 = 32 40 25 6 10 16 80 40 1/2"Gas 12 14 INDUCTIVE CONFORMING TO NAMUR STANDARDS (DIN 19234) APPROVAL EEx ia IIc T4* Ø 3,2 5,3 SIP 12 - N2 SIP 12 - NE4 SIP 17 - NE5 SIP 40 - N15 Sensing surface Sensing surface 80 28 25 40 = 18 40 22 = 32 80 17 6 10 16 10,5 = = 50 Ø 3,2 11 3 65 9 3 14 SIQ 80 - NE50 40 12 M3 SIP 40 - NE20 17 26 18 Ø 3,8 Sensitivity Adjustment Ø 3,2 Sensitivity Adjustment SIP 12 - N2 H1 SIP 12 - NE4 H1 2 SIP 17 - NE5 H1 4 SIP 40 - N15 K SIP 40 - NE20 K 5 15 20 SIQ 80 - NE50 K 10 ÷ 60 (Adjustable) 8,2 ("5 ÷ 30" see note 1 at page 6) In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 500 2000 2000 100 ≤3 -25 ÷ +70 67 (With H1 depending on connector) 65 (IP67 with cable) Plastic 2 x 0.25 mm2 2 x 0.50 mm2 Terminal block (On request cable) 2 x 0.50 mm2 H1 H1 K K - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - SENSITIVITY ADJUSTMENT INSTRUCTIONS FOR CORRECT INSTALLATION A Embeddable Cylindrical models TRIMMER -- A + Embeddable Rectangular models This sensor is supplied with a trimmer for the sensi-tivity adjustment. The sensitivity increases when the trimmer is rotated in the clockwise direction and de-creases in the anticlockwise direction. Avoid using for a capacity greater than 60 mm referred to a square piece of (FE 37) steel of 1 mm thickness the side of which is equal to 100 mm. When setting the sensor keep in consideration all other metallic objects nearby, in fact setting is suggested to be made when the sensor is installed in the normal working conditions. The sensor is supplied already pre-set to 50 mm sensitivity. A B B Not embeddable Cylindrical models A B B Not embeddable Rectangular models SI 6.5 SI 8 SI 12 SI 14 SI 18 SI 30 SIP A8 SIP C8 SIP 10 SIP 12 SIP 17 SIP 40 SIQ 80 (A) ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ mm 4 4 6 7 9 15 2 2 10 6 ≥ 30 - (A) ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ ≥ mm 16 16 24 28 36 60 12 20 50 450 (B) mm ≥ 8 ≥ 8 ≥ 12 ≥ 14 ≥ 18 ≥ 30 ≥ 0 ≥ 6 ≥ 6 ≥ 15 ≥ 70 N.B. A = Mutual interference - B = Interference with metallic part * See page 7 - Applications 9 Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected] NAMUR INDUCTIVE SENSORS RING HOUSING SIA05 - SIA12 - SIA15 - SIA22 - SIA30 - SIA44 - SIA63 - SIA100 2 WIRES D.C. - VERSION N NOT EMBEDDABLE VIEW A 30 (NON FLUSH MOUNTING) 8 40 60 D A 5 TECHNICAL CHARACTERISTICS ø4,2 CABLE 20 = = Dimensions mm SIA 05 - NE SIA 12 - NE VIEW A 30 8 D 40 A 5 SIA 05 - NE H1 mm Hole diameter (D) 5 12 15 In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA Hz 600 ÷ 1000 600 ÷ 1500 % of Sn Repeatability SIA 15 - NE H1 8,2 ("5 ÷ 30" see note 1 at page 6) mA Switching frequency (min-max) H1 PLUG (M8) SIA 12 - NE H1 Continuous voltage (residual ripple ≤10%) V Absorption current at 8.2V SENS. ADJUST. ø4,2 20 = = MODELS WITH CONNECTOR SIA 15 - NE 60 MODELS WITH CABLE SENS. ADJUST. 600 ÷ 1000 < 0.3 Temperature limits °C -20 ÷ +60 Degree of protection IP IP 65 Plastic Housing 2m Cable PUR blue 2 x 0.25 mm2 Connector plug H1 H1 H1 NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - MIN. DIMENSIONS OF THE OBJECT (Fe37) TO DETECT SPECIFICATIONS In ring sensors, the sensing is carried out inside the ring. The sensor intervenes when a metallic object is introduced. They are particularly suitable for checking the presence and counting of small metal objects, screws, nuts washers etc. or for any similar operation. Also useful in verifying breakage of metal wires that pass through the ring. The ring sensor’s housing is in plastic and electrical attachments can be made by means of a cable or M8 and M12 connectors depending on the model type. 10 Model PLUG H1 - H OUTPUT POSITION VIEW SIA05 Length mm 1 Diameter mm 0.7 SIA12 2 1.2 SIA15 2 1.2 SIA22 6 3 SIA30 7 4 SIA44 9 5 SIA63 12 6 SIA100 20 12 SENS. ADJUST. H1 PLUG SENSITIVITY ADJUSTMENT SIA 05-12-15-22 SENS. ADJUST. SIA 30 H PLUG SENS. ADJUST. SIA 44-63 H PLUG SENS. ADJUST. SIA 100 H PLUG ® Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected] ® NAMUR INDUCTIVE SENSORS VIEW A VIEW A SENS. ADJUST. 20 SENS. ADJUST. 140 ØD 85 ØD 29 VIEW A 12 41 INDUCTIVE CONFORMING TO NAMUR STANDARDS (DIN 19234) APPROVAL EEx ia IIc T4* 105 80 ADJUST. 55 40 SENS. 45 70,5 A 165 ØD Ø6,4 Ø5,5 CABLE SIA 30 - NE SIA 44 - NE CABLE A SIA 63 - NE VIEW A SENS. ADJUST. 85 165 105 80 ADJUST. 55 40 140 ØD SENS. 45 70,5 29 SENS. ADJUST. ØD A SIA 100 - NE ØD A 100 VIEW A VIEW A 12 41 60 20 SIA 22 - NE 7,5 CABLE 30 15 Ø 4,3 20 Ø5,5 Ø6,4 H PLUG (M12) H PLUG (M12) 30 H PLUG (M12) A 15 20 7,5 Ø 4,3 A 100 60 SIA 22 - NE H SIA 30 - NE H SIA 44 - NE H SIA 63 - NE H SIA 100 - NE H 22 30 44 63 100 8,2 ("5 ÷ 30" see note 1 at page 6) In presence of metal ≤ 1 mA - In absence of metal ≥ 3 mA 600 ÷ 1000 600 ÷ 800 250 ÷ 600 100 ÷ 200 100 H H < 0.3 -20 ÷ +60 IP 65 Plastic 2 x 0.50 mm2 2 x 0.25 mm2 H H H - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 - NAMUR DIN 19234 - EEx ia IIc T4 SELECTION OF RING SENSOR Selection should be made based on the minimum hole diameter required. In this way the sensitivity adjustment can be made within normal parameters and need not be pushed to the maximum risking the proper functioning of the unit. USE WITH A DELAYED AMPLIFIERS All types of ring sensor can work in combination with a delayed amplifier of the programmable ALTP series or ALNC series which ensures the sensing of small objects in rapid movement. SENSITIVITY ADJUSTMENT After having followed the instructions regarding the choice of the most suitable unit it is recommended that the sensitivity adjustment be carried out when the sensor is installed in the final position taking into account how much metal mass is close by which could alter its functioning. The sensitivity increases turning the trimmer clockwise. EFFECTS OF METAL IN THE CLOSE VICINITY If a moving metal part is close to the sensing area the functioning can be disturbed. In order to avoid this, install the units some distance from metallic objects. Ensure that this does not interfere with the functioning. When applying to a metal surface make sure not to apply too close to ring hole otherwise sensor may notfunction correctly. USE OF SENSOR A distance equal to the width of the sensor should be left between each object that passes through the sensor. If more than one sensor is to be installed in close vicinity, the minimum distance indicated between sensors should be maintained as per chart indications. INSTRUCTIONS FOR CORRECT INSTALLATION Fig. 1 S ≥S Fig. 2 B A ≥S Model ≥S SIA05 SIA12 SIA15 SIA22 SIA30 SIA44 SIA63 SIA100 A (Fig. 1) mm 25 30 30 60 60 300 300 600 B (Fig. 2) mm 10 10 10 20 20 250 250 650 * See page 7 - Applications 11 Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected]
Similar documents
AECO CATALOGUE - z
one or two output relays with changeover contacts, respectively in the ALNC and ALN2 types. They are used to supply with a stabilized and level 12 Vdc voltage inductive and capacitive sensors and p...
More informationTIRE BOOK 2008 - Fighter
The publishers have diligently strived to compile the information contained in this volume correctly and accurately from sources considered reliable. Since the information is subject to change by m...
More informationmagnetic sensors smc-smp series and magnets - z
- When in the exchangeable (S) mode both N.O. an N.C. functions are made available by means of a single galss bulb. Placing the magnet close to or far from the reed switch activates the two differe...
More information