r,™ NO. 28 ServiceBuBetin PARTS CHANGE INFORMATION FOR CAL. 5M42A, 5M43A & 5M45A The generating coil block for Cal. 5M42A, 5M43A and 5M45A has been changed for the purpose of enhancing the electricity-generating efficiency of those watches. Besides this change, the antimagnetic shield plate was removed from the main plate of Cal. 5M42A and 5M43A. These changes will be in effect for the watches produced in and after April 1995. 1. CALIBRES TO BE PROVIDED WITH NEW PARTS Generating coil block: Cal. 5M42A, 5M43A and 5M45A Main plate 2. : Cal. 5M42A and 5M43A REASONS FOR THE CHANGE • G e n e r a t i n g coil b l o c k (For C a l . 5 M 4 2 A , 5 M 4 3 A a n d 5M45A) For the purpose of enhancing the electricity-generating efficiency of the watches and thereby reducing the time during which the watch should be worn on the wrist until the capacitor is fully charged, a generating coil block for exclusive use with Cal. 5M42A, 5M43A and 5M45A was developed. • M a i n plate (For C a l . 5 M 4 2 A a n d 5M43A) Up to now, an anti-magnetic shield plate has been welded to the main plate to prevent the coil block for watch operation from being affected by the A C magnetic field, which is generated when the capacitor is overcharged. The IC was upgraded to take over this preventive measure; therefore, the anti-magnetic shield plate has been removed from the main plate, taking the occasion of renewing the generating coil block. Please note that the main plate for Cal. 5M45A will not be changed as the anti-magnetic shield plate for this calibre is a separate part affixed to the main plate with screws. A s a result of this change. Cal. 5M42Aand 5M43Awill use the samemain plate as usedforCal. 5M23A. SEIKO CORPORATION 1 ^ — Old New For conventional case type (For both Cal. 5M42A and 5M43A) 0100 669 (With anti-magnetic shield plate) 0100 660 (Without anti-magnetic shield plate) For one-piece case type (For both Cal. 5M42A and 5M43A) 0100 659 (With anti-magnetic shield plate) 0100 663 (Without anti-magnetic shield plate) * The old and new main plates can be identified by checking whether the anti-magnetic shield plate is welded on or not. DIFFERENCES BETWEEN OLD AND NEW PARTS Generating coil block Part No. Old New 4002 519 4002 515 White ^^^^^^^^^^^^Red^^ ^^^^^ Color of coil frame 0100 669 (For conventional case type) 0100 660 (For conventional case type) 0100 659 (For one-piece case type) 0100 663 (For one-piece case type) Main plate COMBINED USE OF OLD AND NEW PARTS The old and new parts can or cannot be used in combination as follows. Generating coil block ^ ^ ^ ^ ^ ^ Old 4002 519 New 4002 515 Old 0100 669 0100 659 (With anti-magnetic shield plate) YES YES New 0100 660 0100 663 (Without anti-magnetic shield plate) NO* YES Main plate * Important: Never use an old generating coil block (4002 519) together with a new main plate (0100 660 orOIOO 663), which does not have an anti-magnetic shield plate welded to it. Otherwise, loss/gain of time may be caused by the magnetic field. CHANGES IN "VALUE CHECKING AND ADJUSTMENT" Following the introduction of the new generating coil block, some values for checking and recharging of Cal. 5M42A and 5M43A should be renewed. Please revise the corresponding values in "VALUE CHECKING AND A D J U S T M E N T " in your "PARTS CATALOGUE/TECHNICAL GUIDE Cal. 5M42A, Cal. 5M43A" as follows. • Value checking Old New 4002 519 4002 515 (With white coil frame) (With red coil frame) Generating coil block resistance 280 n ~ 380 ü 1.9 kii ~ 2.3 kil Increase in capacitor voltage after about 100 swings More than 0.1 V More than 0.05 V ^ • ^ ^ ^ ^ Recharging Information Duration of charge Quick movement of the second hand when the power reserve indicator function is activated Number of swings Old New 100 100-150 Approx. 6 hours 5 seconds 400 500 - 600 Approx. 2 days 10 seconds 700 1,000 - 1,300 Approx. 4 days 20 seconds 1,100 1,700 - 2,000 Approx. 7 days 30 seconds Note: The new generating coil block requires more swings to fully charge the capacitor, but it enhances the electricity-generating efficiency when the watch is worn on the wrist. REMARKS Due to the change of the generating coil block for Cal. 5M42A, 5M43A and 5M45A, the new part has lost interchangeability with the generating coil block for Cal. 5M22A and 5M23A. The capacitor for Cal. 5M22A and 5M23A has different characteristics from that for Cal. 5M42A, 5M43A and 5M45A and the use of the new generating coil block for Cal. 5M22A and 5M23A will require more time to increase the voltage up to such a level that the second hand starts moving. Be sure, therefore, to use a generating coil block for exclusive use for each calibre. NOTE O N CURRENT CONSUMPTION FOR CAL. 5M42, 5M43 & 5M45 We are announcing the correction of the current consumption figures described in the PARTS CATALOGUE/TECHNICAL GUIDE and PARTS LIST for the above calibres as follows: — Present figures Corrected figures For the whole movement Less than 0.7 ^A Less than 0.9 ^A For the circuit block alone Less than 0.4 ^lA Less than 0.5 \iA For the whole movement Less than 1.0 ^A Less than 0.9 ^A For the circuit block alone Less than 0.5 ^A Less than 0.5 \LA — 5M42 5M43 5M45 * This correction is not related to the before-mentioned specification change of the coil block.