REGLASSED VESSEL Vessel Type / Size BASE REACTOR SA 750

Transcription

REGLASSED VESSEL Vessel Type / Size BASE REACTOR SA 750
REGLASSED VESSEL
Vessel Type / Size
BASE REACTOR SA 750 GAL.
Ref. Stock Number
108796
Vessel Serial No.
33066
National Board No.
3963
ATTACHED DOCUMENTS
1. Form R-1 Report of Repair
2. Manufacturer’s Data Report U-1 Form
3. Copy of the OEM’s Nameplate
Repair & Reglass Nameplate
4. Final inspection report
5. Plug chart
6. Reference drawing (108796 Rev.0)
If you have any questions on Service or Inquiries on our equipment contact
UGE @ Phone # (609) 586-8004 or Fax # (609) 586-8002.
Stock #108796
Stock #108796
Stock #108796
# 108796-SA 750 GAL.
UGE ROMANIA
QUALITY CONTROL DEPARTMENT
FINAL INSPECTION REPORT
Vessel Type / Size
REACTOR SA 750 GALLONS
Ref. Stock number
Vessel Serial no.
National Board no.
108796
33066
3963
I hereby certify the above equipment has been re-glassed and conforms
to UGE-R’s Quality Specification QS-001-99 and the results are:
Visual inspection
Satisfactory
Glass thickness
0.040 -0.063 inches
(within specification)
Plugs
None
Spark tested
(20 Kv during fabrication
& 6 Kv before packing)
Satisfactory
Quality Assurance Supervisor
Rodica Robotin
February 04, 2013
PLUG CHART
CUSTOMER:
CUSTOMER P. O: #
ITEM: # REACTOR SA 750 GALLONS
Stock No.
Serial No.
NB Number
108796
33066
3963
SIZE & TYPE
PLUGS
#1
#2
#3
#4
NONE
PATCH OR SLEEVE: NONE
COMMENTS
SPARK TESTED
( at 20 Kv during fabrication & 6 Kv before packing )
SATISFACTORY
INSPECTION
Quality Control Inspector
Inspected by
DATE: February 04, 2013
Quality Assurance Supervisor
Approved by
DATE: February 04, 2013

Similar documents