WI - Metl-Span

Transcription

WI - Metl-Span
~----------------~ METL
SPAN•
A Divioion of NCI Grou,, I no.
DISCLAIMER:
These details are based on industry accepted practices and provide a guideline for
proper insulated metal panel and component installation.
The location of vapor barriers and associated sealants shown in these details is
based on standard design practices for commercial industrial applications for
most U.S. and Canadian climatic zones. The default vapor barrier location is on
the warm side in winter (the interior side of the panels).
For projects located in extremely cold climates, exposed to high wind-driven rain
or unusual interior conditions (sustained temperatures below 65°f), it may be
advisable to modify the vapor barrier (joint sealant) location, or to add optional
exterior joint sealants.
It is the sole responsibility of the project architect to verity vapor barrier location.
insulation required by code and HVAC equipment/ventilation requirements to allow
proper air flow and the prevention of condensation.
It is also the sole responsibility of the project architect to determine project-specific
design loads. Meti-Span Technical Services is available to verity allowable panel
spans and fastening requirements when provided with this information.
The details contained herein show side joint fastening only. Please contact
Meti-Span technical services for project-specific fastening requirements.
All structural supports are shown for clarity only, and are not provided by Meti-Span.
COMMERCIAL &
INDUSTRIAL
DISCLAIMER
CI-CF-INF0-1
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
Butyl caulk: For commerical/industrial projects the caulk is usually applied to the
interior joint female pocket (see DISCLAIMER). Butyl caulk is also used to create
~~marriage beads .. which tie the panel sidejoint vapor seals to panel endjoint vapor
seals. Butyl caulk is considered II non-skinning .. , which means it stays soft, flexible,
and does not harden. Butyl caulk is for unexposed areas only, and cannot be
used where it will be exposed to weather or sunlight
Butyl sealant tape: Applied between flashings and panels to form a weathertight
seal. All fasteners penetrating the flashing must be inserted through the sealant
tape.
Urethane caulk: Used in lieu of butyl sealant where there is exposure to the
elements. It is recommended for lapped trims, exposed perimeter seals at framed
openings or to seal between different construction materials, such as metal to
concrete.
Panel fasteners: Insulated metal panel fasteners are generally either
self-drilling/self-tapping (also known as TEK screws), or self-tapping (also known
as B point screws).
TEK Fasteners contain a built-in drill point, and do not require pre-drilling. They
are the quickest and easiest way to attach panels to light-medium gauge
supports.
B Point fasteners require a two-step operation: First holes are pre-drilled into the
panel and structural support with an appropriate sized bit, then the fastener is
inserted into the hole and tightened. B points are typically used to attach panels to
medium-heavy gauge supports that are not penetrable by TEK fasteners. It is
important that the pre-drilled holes are sized correctly for the fasteners to achieve
proper pullout values.
Bulb-lite® Rivets: Are similar to expansion fasteners, and are used where back
fastening of the panels to structural supports is required. Holes must be
pre-drilled with a 5/16 .. diameter. The grip range of the rivets must be matched to
the thickness of the structural support to ensure proper fastening.
COMMERCIAL &
INDUSTRIAL
SEALANTS & FASTENERS
CI-CF-INF0-2
12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, 1no.
~-----------J~-----------Jr-~----------~r------------~J~
CF-42, CF-36
FLUTE/MESA
;;00
~·~
~------~~--------~?
CF-42, CF-36, CF30
MESA/MESA
-~--r~__E_E~-0----------------------~~~~--------------------------------~~~
CF-36A, CF-30A
ARCHITECTURAL FLAT/MESA
,;;···
~·~
~------------------------~------------------------------~?
CF-36, CF-42
SANTA FE
£_~_~EEND------~~--------~~?
CF-42, CF-36, CF-30
STRIATED/MESA
COMMERCIAL &
INDUSTRIAL
PANEL PROFILES
CI-CF-JT -01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, 1no.
36" 7.2 INSUL-RIB
J
\_/,...---......--\_)
\_/
36" LS 36
1~
'' .
-~
"""
'
.
"""
'
.
"""
"0 .
"""
'
.
"""
CF-36, CF-42
TUFF-CAST, TUFF-WALL
COMMERCIAL &
INDUSTRIAL
PANEL PROFILES
'
.
"""
0 .
0)
CI-CF-JT -02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
WI 1/4" HWH FASTENERS
@ EACH WALL SUPPORT
INTERIOR
WALL SUPPORT
CLIP AND FASTENER ASSEMBLY
JOINT SEALANT
WALL SUPPORT
INTERIOR
OPTIONAL
JOINT SEALANT
SEE DETAIL "A"
JOINT SEALANT APPLICATION
NON-SKINNING BUTYL SEALANT
1/4" UNIFORM BEAD MIN.
@LOCATION SPECIFIED
OPTIONAL
JOINT SEALANT
INTERIOR
DETAIL A
WALL SUPPORT
1/B" MAX@ JOINT
COMMERCIAL &
INDUSTRIAL
CF PANEL JOINT DETAILS
CI-CF-JT -03
DATE: 12-16-2015
INTERIOR SURFACE
METL
SPAN•
A Divioion of NCI Grou,, I no.
./
./
./
./
EXTERIOR SURFACE
WALL SUPPORT
14 GA. CLIP
1/4" HWH
FASTENERS
WALL SUPPORT
(14GA. MINIMUM)
PANEL CLIP
@ EACH WALL SUPPORT
COMMERCIAL &
INDUSTRIAL
ATTACHMENT- SIDEJOINTPRE-ENGINEERED SUPPORT
CI-CF-FSTN-01A
DATE: 12-16-2015
INTERIOR SURFACE
METL
SPAN•
A Divioion of NCI Grou,, I no.
EXTERIOR SURFACE
STRUCTURAL STEEL
STRUCTURAL STEEL
14 GA. CLIP
1/4" HWH
FASTENERS
I
I
I
I
I
I
I
I
I
I
I
I
14 GA. CLIP
W/FASTENERS
COMMERCIAL &
INDUSTRIAL
ATTACHMENT- SIDEJOINTSTRUCTURALSTEELSUPPORT
CI-CF-FSTN-01 B
DATE: 12-16-2015
METL
SPAN•
2 HOLE GIRT CLIP
A Divioion of NCI Grou,, I no.
DOME HEAD
BULB-TITE® RIVETS
* INSTALL THROUGH GIRT CLIPS
INTO MESA WHERE THE SKIN
MAKES CONTACT WITH THE STEEL
INTERIOR SIDE
STRUCTURAL STEEL
BULB-TITE® RIVET
GIRT CLIP
14 GA. CLIP
GIRT CLIP
1/4" HWH
BULB-TITE®
RIVET
FASTENERS
STRUCTURAL STEEL
COMMERCIAL &
INDUSTRIAL
ATTACHMENT- BACK FASTENED
WI GIRT CLIPS
CI-CF-FSTN-01 C
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
DOME HEAD
BULB-TITE® RIVETS
* INSTALL THROUGH GIRT
FLANGE INTO MESA WHERE THE
SKIN MAKES CONTACT WITH STEEL
INTERIOR SIDE
WALL SUPPORT
14 GA. CLIP
BULB-TITE® RIVET
1/4" HWH
FASTENERS
WALL SUPPORT
I
I
BULB-TITE® RIVET
I
I
I
I
I
I
I
I
I
14 GA. CLIP
W/FASTENERS
COMMERCIAL &
INDUSTRIAL
ATTACHMENT- BACK FASTENED
WI RIVETS
CI-CF-FSTN-01 D
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
(FP1)
FASTENING PATTERN 1
SIDE JOINT FASTENING
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
(FP2)
FASTENING PATTERN 2
SIDE JOINT FASTENING
AND ONE DOME HEAD
BULB-TITE® RIVET
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
(CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS)
COMMERCIAL &
INDUSTRIAL
FASTENING PATTERNS
CI-CF-FP 1-2
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
10.5"
(FP3)
FASTENING PATTERN 3
SIDE JOINT FASTENING
AND TWO DOME HEAD
BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
10.5"
10.5''
(FP4)
FASTENING PATTERN 4
SIDE JOINT FASTENING
WITH THREE DOME HEAD
BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
(CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS)
COMMERCIAL &
INDUSTRIAL
FASTENING PATTERNS
CI-CF-FP 3-4
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
5.25"
10.5''
10.5"
10.5"
5.25"
(FP5)
FASTENING PATTERN 5
SIDE JOINT FASTENING
AND BACK FASTENING WITH
FOUR DOME HEAD BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
(FP6)
FASTENING PATTERN 6
SIDE JOINT FASTENING
AND ONE GIRT CLIP WITH TWO DOME HEAD
BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
(CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS)
COMMERCIAL &
INDUSTRIAL
FASTENING PATTERNS
CI-CF-FP 5-6
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
10.5"
(FP7)
FASTENING PATTERN 7
SIDE JOINT FASTENING
AND TWO GIRT CLIPS WITH FOUR DOME HEAD
BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
DIMENSION IS FROM
FEMALE EDGE +/- 1.5"
10.5"
10.5"
10.5''
(FP8)
FASTENING PATTERN 8
SIDE JOINT FASTENING
WITH THREE GIRT CLIPS WITH SIX DOME HEAD
BULB-TITE® RIVETS
INSTALL RIVET THROUGH GIRT FLANGE
INTO MESA WHERE THE SKIN MAKES
CONTACT WITH THE STEEL
(CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS)
COMMERCIAL &
INDUSTRIAL
FASTENING PATTERNS
CI-CF-FP 7-8
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
8.4"
8.4"
8.4"
8.4"
8.4"
(FP9)
FASTENING PATTERN 9
WITH FOUR SELF-TAPPING
SCREWS WITH MIN. 20 GA.
NEOPRENE BONDED WASHER
8.4"
-
8.4"
8.4"
-
-
-
-
-
8.4"
8.4"
-
-
-
~~
(FP1 0)
-
-
-
I
~
FASTENING PATTERN 10
WITH FIVE SELF-TAPPING
SCREWS WITH MIN. 20 GA.
NEOPRENE BONDED WASHER
(CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS)
COMMERCIAL &
INDUSTRIAL
FASTENING PATTERNS
CI-CF-FP 9-10
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATTACHMENT
(NOT BY PANEL MANUFACTURER}
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUYTL SEALANT
[7100BWH]
BASE TRIM
[F3369]
#12 PANCAKE STITCH FASTENER
[12A]
1/8" Q> RIVETS
@ 12"0.C.
[14]
FINISH FLOOR
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
BASE FLASHING
[SEE CHART]
BASE ATTACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
4
<C1
<1
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[71 OOBWH]
BUTYL SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
FLASHING
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5001
1616PNC
1724PNC
1816PNC
2.5"
F5013
1624PNC
1732PNC
1824PNC
2.75"
F5071
1624PNC
1732PNC
1824PNC
3"
F5034
F5050
1624PNC
1732PNC
1632PNC
1740PNC
1824PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
BASE - OVERHANG
WI NOTCHED SLAB
CI-CF-BE-02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATTACHMENT
(NOT BY PANEL MANUFACTURER)
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUYTL SEALANT
[7100BWH]
#12 PANCAKE STITCH FASTENER
[12A]
1/8" !II RIVETS
@ 12"0.C.
[14]
FINISH FLOOR
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
BASE ATTACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
BASE FLASHING
[SEE CHART]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
<J
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
FLASHING
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5002
1616PNC
1724PNC
1816PNC
2.5"
F5014
1624PNC
1732PNC
1824PNC
2.75"
F5072
1624PNC
1732PNC
1824PNC
3"
F5032
F5053
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
WI
BASE - OVERHANG
NOTCHED SLAB- ALT.
CI-CF-BE-04
DATE: 3-17-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATIACHMENT
(NOT BY PANEL MANUFACTURER)
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUTYL SEALANT
[7100BWH]
BASE TRIM
[F3369]
#12 PANCAKE STITCH FASTENER
[12A]
1/8" 16 RIVETS
@ 12"0.C.
[14]
FINISH FLOOR
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
BASE ATIACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
BASE FLASHING
[SEE CHART]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
FLASHING
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5001
1616PNC
1724PNC
1816PNC
2.5"
F5013
1624PNC
1732PNC
1824PNC
2.75"
F5071
1624PNC
1732PNC
1824PNC
3"
F5034
F5050
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
BASE - OVERHANG
WI DRIP TRIM
CI-CF-BE-06
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATIACHMENT
(NOT BY PANEL MANUFACTURER)
BUTYL SEALANT
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
#12 PANCAKE STITCH FASTENER
[12A]
FINISH FLOOR
1/8" ~ RIVETS
@8"0.C.
[14]
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
BASE FLASHING
[SEE CHART]
BASE ATIACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
PANEL SUPPORT ANGLE
(NOT BY PANEL MANUFACTURER)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
FLASHING
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
F5076
1616PNC
1724PNC
1816PNC
2.5"
F5077
1624PNC
1732PNC
1824PNC
2.75"
F5078
1624PNC
1732PNC
1824PNC
3"
F5079
F5080
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
BASE - OVERHANG
WI EDGE TRIM
CI-CF-BE-07
DATE: 01-14-2016
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
r- -r
T
-TV- ,14 GA. PANEL CLIP
[4633GNC]
~
1
~!
1/4" HWH CLIP FASTENERS
[SEE CHART] ~
~
~~
/
BASE ATIACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
~---::1)
1
CONTINUOUS BASE ATIACHMENT
(NOT BY PANEL MANUFACTURER)
/
I-,..
I
FINISH FLOOR ~
I
1/8" !II RIVETS
@S"O.C. ~ .
v
~ D
[14]
BASE FLASHING
:
Ll
~ L...J...._:;;;;;;;;~'Jif:J·
[SEE CHART]
Ll
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
FLASHING
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
F5076
1616PNC
1724PNC
1816PNC
2.5"
F5077
1624PNC
1732PNC
1824PNC
2.75"
F5078
1624PNC
1732PNC
1824PNC
3"
F5079
1624PNC
1732PNC
1824PNC
4"
F5080
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
BASE - OVERHANG
WI BASE SUPPORT
CI-CF-BE-08
DATE: 2-25-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
FIELD NOTCH HEM(S}
AS REQUIRED
(2) BEADS
URETHANE SEALANT
~~
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP BASE
CI-CF-EL-8
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATTACHMENT
(NOT BY PANEL MANUFACTURER)
BUYTL SEALANT
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
#12 PANCAKE STITCH FASTENER
[12A]
WI PER GASKET
[7800VGR]
FINISH FLOOR
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
FIELD DRILL 3/8" ¢ MIN.
WEEP HOLES
@ 24" o.c.
BASE ATTACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
BASE EXTRUSION
[SEE CHART]
SPLICE BAR
[9495A]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
EXTRUSION
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
9405A
1616PNC
1724PNC
1816PNC
2.5"
9406A
1624PNC
1732PNC
1824PNC
3"
9407A
9404A
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
WI
BASE - OVERHANG
NOTCHED SLAB, EXTRUSION
CI-CF-EB-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS BASE ATIACHMENT
(NOT BY PANEL MANUFACTURER)
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUTYL SEALANT
[7100BWH]
#12 PANCAKE STITCH FASTENER
[12A]
WIPER GASKET
[7800VGR]
FINISH FLOOR
BASE EXTRUSION
[SEE CHART]
CONC. FASTENERS
(NOT BY PANEL MANUFACTURER)
FIELD DRILL 3/8" f/J MIN.
WEEP HOLES
@24" o.c.
BASE ATIACHMENT
SET IN CONTINUOUS
BEAD OF URETHANE SEALANT
[HW540]
SPLICE PLATE
[9495A]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[71008WH]
BUTYL SEALANT
[71 OOBWH]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
ALTERNATE PLACEMENT OF SEALANT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
BASE
EXTRUSION
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
9405A
1616PNC
1724PNC
1816PNC
2.5"
9406A
1624PNC
1732PNC
1824PNC
3"
9407A
9404A
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
4"
COMMERCIAL &
INDUSTRIAL
BASE - OVERHANG
WI EXTRUSION
CI-CF-EB-02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
CORNER TRIM
[F5140]
1/4" PANCAKE FASTENER
@ EACH SUPPORT
[SEE CHART]
1/8" 0 RIVETS
@B"O.C.
[14]
BUTYL SEALANT
[7100BWH]
SEALANT TAPE
(AS REQUIRED)
EXPANDABLE FOAM
INSULATION
(NOT BY PANEL MANUFACTURER)
CORNER TRIM
[SEE CHART]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
CORNER TRIM
PANCAKE HEAD
TYPE3
2"
F5102
1424PNC
2.5"
F5103
1432PNC
2.75"
F5105
1432PNC
3"
F5104
F5101
1432PNC
4"
COMMERCIAL &
INDUSTRIAL
1440PNC
OUTSIDE CORNER
WI FLUSH TRIM
CI-CF-CE-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
1/8" 16 RIVETS
@SUPPORTS
1/8" 1/J RIVETS
@8"
[14]
[14]
BUTYL SEALANT
[7100BWH]
o.c.
CORNER TRIM
[F5140]
1/4" PANCAKE FASTENER
@ EACH SUPPORT
[SEE CHART]
SEALANT TAPE
(AS REQUIRED)
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
CORNER TRIM
PANCAKE HEAD
TYPE3
2"
F5102
1424PNC
2.5"
F5103
1432PNC
2.75"
F5105
1432PNC
3"
F5104
1432PNC
4"
F5101
1440PNC
COMMERCIAL &
INDUSTRIAL
INSIDE CORNER
WI FLUSH TRIM
CI-CF-CE-03
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
a..
:5
'ol
C\J~
a:
I--
FIELD NOTCH HEM(S)
AS REQUIRED
a..
(2) BEADS
URETHANE SEALANT
:5
a:
I--
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP CORNER
CI-CF-EL-C
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
IV
Atl. . .~
I::::M
SUPPORTS
FEMALE CORNER EXTRUSION
[9430A]
BUTYL SEALANT
[7100BWH]
#12 PANCAKE STITCH FASTENER
@ EACH SUPPORT
WI PER GASKET
[7800VGR]
[12A]
1/4" PANCAKE FASTENER
@ EACH SUPPORT
[SEE CHART]
BUTYL SEALANT
[7100BWH]
FIELD MITER PANEL
MALE CORNER
EXTRUSION
[9425A]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
MALE CORNER
EXTRUSION
FEMALE CORNER
EXTRUSION
PANCAKE HEAD
TYPE3
2"
9425ANC
9430ANC
1424PNC
2.5"
9425ANC
9431ANC
1432PNC
3"
9425ANC
9432ANC
1432PNC
4"
9429ANC
9433ANC
1440PNC
COMMERCIAL &
INDUSTRIAL
WI
OUTSIDE CORNER
TWO PIECE EXTRUSION
CI-CF-EC-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
MALE CORNER EXTRUSION
[SEE CHART]
#12 PANCAKE STITCH FASTENER
@ EACH SUPPORT
[12A]
BUTYL SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
FEMALE CORNER EXTRUSION
[SEE CHART]
1/4" PANCAKE FASTENER
@EACH SUPPORT
[SEE CHART]
WIPER GASKET
[7800GVR]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
MALE CORNER
EXTRUSION
FEMALE CORNER
EXTRUSION
PANCAKE HEAD
TYPE3
211
9435ANC
9440ANC
1424PNC
COMMERCIAL &
INDUSTRIAL
WI
INSIDE CORNER
TWO PIECE EXTRUSION
CI-CF-EC-02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
CONTINUOUS URETHANE SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[HW540]
14 GA. PANEL CLIP
[4633GNC]
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUTYL SEALANT
[7100BWH]
EXTERIOR HEAD TRIM
[F5044]
#12 PANCAKE
STITCH SCREW
[12A]
URETHANE SEALANT
[HW540]
1/8"
~
SUPPORT
POP RIVET
8" D.C.
[14]
WINDOW /DOOR/LOUVER/FRAM lNG
(NOT BY PANEL MANUFACTURER)
INTERIOR HEAD TRIM
[SEE CHART]
URETHANE SEALANT
[HW540]
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
INTERIOR
HEAD TRIM
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5045
1616PNC
1724PNC
1816PNC
2.5"
F5046
1624PNC
1732PNC
1824PNC
2.75"
F5047
1624PNC
1732PNC
1824PNC
3"
F5048
1624PNC
1732PNC
1824PNC
4"
F5049
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
HEAD W/ TWO PIECE TRIM
CI-CF-HD-01
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
CONTINUOUS URETHANE SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[HW540]
14 GA. PANEL CLIP
[4633GNC]
BUTYL SEALANT
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
#12 PANCAKE
STITCH SCREW
[12Al
EXTERIOR HEAD TRIM
[F5044]
SUPPORT
HEAD TRIM
(OPTIONAL)
URETHANE SEALANT
[HW540]
1/8"
~
URETHANE SEALANT
[HW540]
POP RIVET
8" O.C.
[14]
INTERIOR HEAD TRIM
[SEE CHART]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
INTERIOR
HEAD TRIM
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5045
1616PNC
1724PNC
1816PNC
2.5"
F5046
1624PNC
1732PNC
1824PNC
2.75"
F5047
1624PNC
1732PNC
1824PNC
3"
F5048
1624PNC
1732PNC
1824PNC
4"
F5049
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
O.H. DOOR HEAD
WI TWO PIECE TRIM
CI-CF-HD-02
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
FIELD NOTCH HEM(S)
AS REQUIRED
(2) BEADS
URETHANE SEALANT
-----..,.~
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP TWO PIECE HEAD
CI-CF-EL-H
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
INTERIOR HEAD EXTRUSION
[SEE CHART]
14 GA. PANEL CLIP
[4633GNC]
CONTINUOUS URETHANE SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[HW540]
1/4" HWH CLIP FASTENERS
[SEE CHART]
BUTYL SEALANT
[7100BWH]
WIPER GASKET
[7BOOVGR]
#12 PANCAKE
STITCH SCREW
[12A]
EXTERIOR HEAD EXTRUSION
[9415A]
FIELD DRILL 3/8" ¢ MIN.
WEEP HOLES
@ 24" o.c.
SUPPORT
URETHANE SEALANT
[HW540]
WIN DOW/DOOR/LOUVER/FRAMING
(NOT BY PANEL MANUFACTURER)
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS.
T
INTERIOR HEAD
EXTRUSION
TYPE 3 CLIP
FASTENER
TYPE 5 CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
9420A
1616PNC
1724PNC
1816PNC
2.5"
9421A
1624PNC
1732PNC
1824PNC
3"
9422A
1624PNC
1732PNC
1824PNC
4"
9423A
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
HEAD W/ TWO PIECE EXTRUSION
CI-CF-EH-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
INTERIOR HEAD EXTRUSION
[SEE CHART]
CONTINUOUS URETHANE SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[HW540]
14 GA. PANEL CLIP
[4633GNC]
BUTYL SEALANT
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
#12 PANCAKE
STITCH SCREW
[12A]
WI PER GASKET
[7800VGR]
EXTERIOR HEAD EXTRUSION
[9415A]
SUPPORT
HEAD TRIM
(OPTIONAL)
FIELD DRILL 3/8" ¢ MIN.
WEEP HOLES
@ 24" O.C.
URETHANE SEALANT
[HW540]
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS.
T
INTERIOR HEAD
EXTRUSION
TYPE 3 CLIP
FASTENER
TYPE 5 CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
9420A
1616PNC
1724PNC
1816PNC
2.5"
9421A
1624PNC
1732PNC
1824PNC
3"
9422A
1624PNC
1732PNC
1824PNC
4"
9423A
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
WI
O.H. DOOR HEAD
TWO PIECE EXTRUSION
CI-CF-EH-02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
SUPPORT
WINDOW/LOUVER/DOOR/FRAMING
(NOT BY PANEL MANUFACTURER)
1/4" PANCAKE FASTENER
(NOT TO EXCEED 5'-0" O.C.)
[SEE CHART]
BUTYL SEALANT
[7100BWH]
INTERIOR JAMB TRIM
[SEE CHART]
BUTYL SEALANT
[7100BWH]
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
URETHANE SEALANT
[HW540]
BUTYL TAPE
[7300BGR]
1/8" Ill POP RIVET
8" O.C.
[14]
1/8" Ill RIVETS
@8"0.C.
URETHANE SEALANT
[HW540]
[14]
EXTERIOR JAMB TRIM
[F27]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
INTERIOR
JAMB TRIM
PANCAKE HEAD
TYPE3
211
F5442
1424PNC
2.511
2.7511
F5442
1432PNC
F5442
1432PNC
311
F5443
1432PNC
411
FF443
1440PNC
COMMERCIAL &
INDUSTRIAL
JAMB W/ TWO PIECE TRIM
CI-CF-JB-01
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
SUPPORT
WINDOW/LOUVER/DOOR/FRAMING
(NOT BY PANEL MANUFACTURER)
BUTYL SEALANT
[7100BWH]
1/4" PANCAKE FASTENER
(NOT TO EXCEED 5'-0" O.C.)
[SEE CHART]
BUTYL SEALANT
[7100BWH]
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
BUTYL TAPE
[7300BGR]
1/8" riJ RIVETS
@B"O.C.
[14]
FLAT JAMB TRIM
[SEE CHART]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
FLAT
JAMB TRIM
PANCAKE HEAD
TYPE3
211
F5390
1424PNC
2.511
2.7511
F5392
1432PNC
F5394
1432PNC
311
F5396
1432PNC
411
F5398
1440PNC
COMMERCIAL &
INDUSTRIAL
JAMB W/ DEEP TRIM
CI-CF-JB-02
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
FIELD NOTCH HEM(S)
AS REQUIRED
(2) BEADS
URETHANE SEALANT
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP TWO PIECE JAMB
CI-CF-EL-J
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
SUPPORT
WINDOW/LOUVER/DOOR/FRAM lNG
(NOT BY PANEL MANUFACTURER)
1/4" THRU FASTENER
(NOT TO EXCEED 5'-0" O.C.)
[SEE CHART]
#12 PANCAKE STITCH
SCREW@ ENDS
[12A]
BUTYL SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
URETHANE SEALANT
[HW540]
WIPER GASKET
[7800VGR]
FEMALE JAMB EXTRUSION
[SEE CHART]
BUTYL SEALANT
[7100BWH]
MALE JAMB EXTRUSION
[9415A]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
FEMALE
JAMB EXTRUSION
TYPE 3THRU
FASTENER
TEK5THRU
FASTENER
TYPE BTHRU
FASTENER
211
9420A
1424PNC
1732PNC
1824PNC
2.511
311
9421A
1432PNC
1740PNC
1832PNC
9422A
1432PNC
1740PNC
411
9423A
1440PNC
1748PNC
1832PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
JAMB W/ EXTRUSION
CI-CF-EJ-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
SUPPORT
1/4" PANCAKE FASTENER
(NOT TO EXCEED 5'-0" O.C.)
[SEE CHART]
JAMB WRAP TRIM
(OPTIONAU
BUTYL SEALANT
[71 OOBWH]
INTERIOR JAMB TRIM
[SEE CHART]
BUTYL SEALANT
[71 OOBWH]
URETHANE SEALANT
[HW540]
1/8" ~ POP RIVET
@8"0.C.
[14]
BUTYL TAPE
[71 OOBWH]
URETHANE SEALANT
[HW540]
1/8" ~ RIVETS
@8"
o.c.
[14]
EXTERIOR JAMB TRIM
[F27]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
INTERIOR
JAMB TRIM
PANCAKE HEAD
TYPE3
211
F5442
1424PNC
2.511
311
F5442
1432PNC
F5443
1432PNC
411
F5443
1440PNC
COMMERCIAL &
INDUSTRIAL
O.H. DOOR JAMB
WI TWO PIECE TRIM
CI-CF-DJ-01
DATE: 01-14-2016
METL
SPAN•
A Divioion of NCI Grou,, I no.
SUPPORT
1/4" THRU FASTENER
(NOT TO EXCEED 5'-0" O.C.)
[SEE CHART]
JAMB WRAP TRIM
~ (OPTIONAU
#12 PANCAKE STITCH
SCREW@ ENDS
[12A]
BUTYL SEALANT
[7100BWH]
BUTYL SEALANT
[7100BWH]
URETHANE SEALANT
[HW540]
FEMALE JAMB EXTRUSION
[SEE CHART]
WIPER GASKET
[7800VGR]
MALE JAMB EXTRUSION
[9415A]
BUTYL SEALANT
[7100BWH]
REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
FEMALE
JAMB EXTRUSION
TYPE 3THRU
FASTENER
TEK5THRU
FASTENER
TYPE BTHRU
FASTENER
211
9420A
1424PNC
1732PNC
1824PNC
2.511
311
9421A
1432PNC
1740PNC
1832PNC
9422A
1432PNC
1740PNC
411
9423A
1440PNC
1748PNC
1832PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
O.H. DOOR JAMB
WI EXTRUSION
CI-CF-ED-01
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
#12 PANCAKE STITCH SCREW
@ 12" O.C.
/
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
tr======='lf
SILL TRIM
(SEE CHART]
~
1/8" ~ RIVETS
@8" O.C.
[14]
FLASHING SEALANT TAPE
[7405BWH]
A
1
I.
SUPPORT
~
~
WINDOW/LOUVER/DOOR/FRAM lNG
(NOT BY PANEL MANUFACTURER)
Rl··-~
~'
'==
~
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
SEALANT
=
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
FLUTE PLUG STRIP
(1) PER PANEL
(IF REQUIRED)
SET IN URETHANE SEALANT
[7607UGR]
14 GA. PANEL CLIP
[4633GNC]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
SILL TRIM
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5501
1616PNC
1724PNC
1816PNC
2.5"
F5503
1624PNC
1732PNC
1824PNC
2.75"
-
3"
F5507
1624PNC
1624PNC
1732PNC
1732PNC
1824PNC
1824PNC
4"
F5509
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
SILL DETAIL
WI FLAT TRIM
CI-CF-SL-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
FIELD NOTCH
HEM(S)
AS REQUIRED
(2) BEADS
URETHANE SEALANT
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP SILL
CI-CF-EL-S
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
#12 PANCAKE STITCH SCREW
@ 12"0.C.
WINDOW/LOUVER/DOOR/FRAMING
/
PERIMETER SEALANT
(NOT BY PANEL MANUFACTURER)
tr======='ll'
SILL EXTRUSION
[SEE CHART]
I
(NOT BY PANEL MANUFACTURER)
SUPPORT
~ +-------llr-.---,--~-------=--..J~I ~
BUTYL SEALANT
[7100BWH]
~
'==
WIPER GASKET
[7800VGR]
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
SEALANT
=
[7100BWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
FLUTE PLUG STRIP
(1) PER PANEL
(IF REQUIRED)
SET IN URETHANE SEALANT
[7607UGR]
14 GA. PANEL CLIP
[4633GNC]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
SILL
EXTRUSION
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
9413A
1616PNC
1724PNC
1816PNC
2.5"
9413A
1624PNC
1732PNC
1824PNC
3"
9413A
1624PNC
1732PNC
1824PNC
4"
9412A
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
SILL DETAIL
WI EXTRUSION
CI-CF-ES-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
URETHANE END DAM
® INTERIOR HEAD TRIM
WITH TABS BENT DOWN
URETHANE SEALANT
@ EXTERIOR HEAD TRIM
FIELD CUT/NOTCH
CAP TRIM AT CORNERS
TO ALLOW FOR LAP
@SILL TRIM
WITH TABS BENT UP
@ EXTERIOR JAMB TRIM
BUTYL
SEALANT
FIELD CUT/NOTCH
CAP TRIM AT CORNERS
TO ALLOW FOR LAP
EXPOSED SEALANT
(NOT BY PANEL PANEL
MANUFACTURER)
CD INTERIOR
JAMB TRIM
TRIM INSTALLATION SEQUENCE:
CD INTERIOR JAMB TRIMS
®INTERIOR HEAD TRIM WITH TABS BENT DOWN (NOTCHED)
@SILL TRIM WITH TABS BENT UP (NOTCHED)
@ EXTERIOR JAMB TRIMS
@ EXTERIOR HEAD TRIM
COMMERCIAL &
INDUSTRIAL
TRIM LAPS AT FRAMED OPENING
CI-CF-T-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
URETHANE END DAM
URETHANE END DAM
®INTERIOR
HEAD EXTRUSION
@)EXTERIOR
HEAD EXTRUSION
3/8" 0 WEEP HOLES
@EXTERIOR
JAMB EXTRUSION
BUTYL
SEALANT
EXPOSED SEALANT
(NOT BY PANEL PANEL
MANUFACTURER)
@SILL EXTRUSION
CD INTERIOR
JAMB EXTRUSION
EXTRUSION INSTALLATION SEQUENCE:
d) INTERIOR JAMB EXTRUSIONS
(g) INTERIOR HEAD EXTRUSION (NOTCHED)
@SILL EXTRUSION (NOTCHED)
@ EXTERIOR HEAD EXTRUSION (NOTCHED)
@ EXTERIOR JAMB EXTRUSIONS
COMMERCIAL &
INDUSTRIAL
EXTRUSION AT FRAMED OPENING
CI-CF-E-01
DATE: 12-16-2015
METL
SPAN•
1.. . 1
T
-
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
[4633GNC] ~
1/4" HWH CLIP FASTENERS
[SEE CHART]
~
BASE TRIM
@8" O.C.
[14]
~t
1
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD
TO VERTICAL PANEL
JOINT SEALANT
[7100BWH]
l
[~~~
1/8" Ill RIVET
#12 PANCAKE
STITCH SCREW
[12A]
~ t
0~ 11$1111
.~
.
~
*
+-----I~
SR
~
rl
SUPPORT
/-=
-
WORK
~t=====---r;::;:
f ~~~ ~~:
STACK JOINT TRIM
[SEE CHART]
fi
FLASHING SEALANT TAPE
[7405BWH]
~
~
POINT~
ELEV
1
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[71 OOBWH]
I
FLUTE PLUG STRIP
(1) PER PANEL
(IF REQUIRED)
SET IN URETHANE SEALANT
[7607UGR]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
STACK JOINT
TRIM
TYPE 3 CLIP
FASTENER
TYPES CLIP
FASTENER
TYPE BCLIP
FASTENER
2"
F5701
1616PNC
1724PNC
1816PNC
2.5"
F5703
1624PNC
1732PNC
1824PNC
2.75"
-
1624PNC
1732PNC
1824PNC
3"
F5707
1624PNC
1732PNC
1824PNC
4"
F5709
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
STACK JOINT
WI TRIM
CI-CF-SJ-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
FIELD NOTCH HEM(S)
AS REQUIRED
(2) BEADS
URETHANE SEALANT
NOTE: POP RIVET OR STITCH
SCREW AS NECESSARY
COMMERCIAL &
INDUSTRIAL
TRIM END LAP STACK JOINT
CI-CF-EL-SJ
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
14 GA. PANEL CLIP
~
[4633GNC] 1/4" HWH CLIP FASTENERS
[SEECHART]
#12 PANCAKE
STITCH FASTENER
~ ~:
WIPER GASKET
[
]
7800GVR
[12A]
:
~
:
;"'-'{llM-~V
_...
I
STACK JOINT EXTRUSION
[SEE CHART]
SEALANT
[71 OOBWH]
1
1
1
;;00 - - - - - - ' lrL..1-LW...__..._.
~
C')~
11
~
FIELD DRILl_3/B"• MIN.
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT
dJ
t /
WEEP HOLES _ /
@ 24" O.C.
WIPER GASKET
[7800GVR]
:'
~
-=-
~~~~~==============~---~W~O~R~K~P~O~IN~T~J.~
>~
Ivr··i!j~E~
:/ ~
I
)
URETHANE SEALANT
[HW540]
i
:
1
I
'
ELEV
"17
SUPPORT
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
SPLICE BAR
[9495A]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
STACK JOINT
EXTRUSION
lYPE 3 CLIP
FASTENER
1YPE5 CLIP
FASTENER
lYPE BCLIP
FASTENER
2"
9455A
1616PNC
1724PNC
1816PNC
2.5"
9456A
1624PNC
1732PNC
1824PNC
3"
9458A
1624PNC
1732PNC
1824PNC
4"
9459A
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
STACK JOINT
WI EXTRUSION
CI-CF-ESJ-01
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
NOTE:
THIS DETAIL IS FOR INFORMATIONAL
PURPOSES ONLY. ALL ROOF
COMPONENTS, PERIMETER FLASHING
AND SEALANTS ARE
NOT BY PANEL MANUFACTURER
FLASHING SEALANT TAPE
[7405BWH]
FLUTE PLUG STRIP
(1) PER PANEL
(IF REQUIRED)
SET IN URETHANE SEALANT
[7607UGR]
INTERIOR AIR/VAPOR SEAL
(NOT BY PANEL MANUFACTURER)
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[71 OOBWH]
1/4" HWH CLIP FASTENERS
[SEE CHART]
14 GA. PANEL CLIP
[4633GNC]
SUPPORT
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
TYPE Ill CLIP
FASTENER
TYPEVCLIP
FASTENER
TYPE B CLIP
FASTENER
2"
1616PNC
1724PNC
1816PNC
2.5"
1624PNC
1732PNC
1824PNC
3"
1624PNC
1732PNC
1824PNC
2.75"
1624PNC
1732PNC
1824PNC
4"
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
EAVE DETAILCONVENTIONAL ROOF
CI-CF-VE-01
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[7100BWH]
ROOF MEMBRANE &
PARAPET BLOCKING
PARAPET CAP ------.. (NOT BY PANEL MANUFACTURER)
(NOT BY PANEL MANUFACTURER)
i,:::-------'7'-~----------
I
I
1
1/4" HWH CLIP FASTENERS
:
[SEE CHART] --------.......~
1
1
~---------~
-
~
I
"1--,-...-'{l••a
1 I
I
METAL CLEAT AND
)
FORM OF ATTACHMENT _____/
(NOT BY PANEL MANUFACTURER)
~
I
L
~
SUPPORT
~•~FE~
lr-
!
1
FASTENER
(NOT BY PANEL
MANUFACTURER)
=
I
~
~
..
14 GA. PANEL CLIP
FLASHING SEALANT TAPE
[7405BWH]
.
FLUTE PLUG STRIP
(1) PER PANEL
(IF REQUIRED)
SET IN URETHANE SEALANT
[7607UGR]
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
TYPE 3 CLIP
FASTENER
TYPE 5 CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
1616PNC
1724PNC
1816PNC
2.5"
1624PNC
1732PNC
1824PNC
2.75"
3"
1624PNC
1624PNC
1732PNC
1732PNC
1824PNC
1824PNC
4"
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
PARAPET(SUPPORTED)
W/ TRIM
CI-CF-TP-01
DATE: 12-16-2015
METL
SPAN•
-
A Divioion of NCI Grou,, I no.
CONTINUOUS BUTYL SEALANT
WITH MARRIAGE BEAD TO
VERTICAL PANEL JOINT SEALANT
[71 OOBWH]
PARAPET EXTRUSION
(NOT BY PANEL MANUFACTURER) ~
ROOF MEMBRANE &
PARAPET CAP
(NOT BY PANEL MANUFACTURER)
F:::!!!!!==:'::r;r:~.,..,
~
rri!FT~,,_
PARAPET BLOCKING
{NOT BY PANEL MANUFACTURER)
_______
~w~-!FW-~r~IJ!~~
-~~~-~-~~-~-=-=T_'-=_-;
1VAJ:••
~=-~=t~
Iif'::\_5) SUPPORT
1/4" HWH CLIP FASTENERS
[SEECHART]
~
=
FASTENER
(NOT BY PANEL
MANUFACTURER)
v:!
1
14 GA. PANEL CLIP _ _ /
[4633GNC]
·.
REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
T
TYPE 3 CLIP
FASTENER
TYPE 5 CLIP
FASTENER
TYPE B CLIP
FASTENER
2"
1616PNC
1724PNC
1816PNC
2.5"
1624PNC
1732PNC
1824PNC
2.75"
1624PNC
1732PNC
1824PNC
3"
4"
1624PNC
1732PNC
1824PNC
1632PNC
1740PNC
1832PNC
COMMERCIAL &
INDUSTRIAL
PARAPET(SUPPORTED)
WI EXTRUSION
CI-CF-EP-02
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
2" BASE
EXTRUSION
[9405A]
2" STACK JOINT
EXTRUSION
[9455A]
2" BASE/SOFFIT
EXTRUSION
[9414A]
2" HEAD/JAMB EXTRUSION
INTERIOR (FEMALE)
[9420A]
HEAD/JAMB EXTRUSION
EXTERIOR (MALE)
[9415A]
--
2" VERTICAL H J O I N T l f
EXTRUSION
INTERIOR (FEMALE)
[9450A]
2" VERTICAL H JOINT
EXTRUSION
II.
~t:!~?R (MALE)
II
=::::!!IHI!:::=:!-::!1'
1!!::-!!:::'
WIPER GASKET
[?BOOVGR]
EXTRUDED ALUMINUM
SPLICE BAR
[9495A]
2" OUTSIDE CORNER
INTERIOR (FEMALE)
[9430A]
INSIDE CORNER
INTERIOR (MALE)
[9435A]
2" SILL EXTRUSION
[9413A]
OUTSIDE CORNER
EXTERIOR (MALE)
[9425A]
2" INSIDE CORNER
EXTERIOR (FEMALE)
[9440A]
COMMERCIAL &
INDUSTRIAL
11
2 EXTRUSIONS
CI-CF-2-EXT
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,. I no.
2.5" BASE
EXTRUSION
[9406A]
2.5" STACK JOINT
EXTRUSION
[9455A]
2.5" HEAD/JAMB EXTRUSION
INTERIOR (FEMALE)
[9421A]
HEAD/JAMB EXTRUSION
EXTERIOR (MALE)
[9415A]
--
WIPER GASKET
[7800VGR]
11
EXTRUDED ALUMINUM
SPLICE BAR
[9495A]
2.5" OUTSIDE CORNER
INTERIOR (FEMALE)
[9431A]
OUTSIDE CORNER
EXTERIOR (MALE)
[9425A]
COMMERCIAL &
INDUSTRIAL
11
2.5 EXTRUSIONS
CI-CF-2.5-EXT
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
3" BASE EXTRUSION
[9407A]
3" STACK JOINT
EXTRUSION
[9458A]
3" HEAD/JAMB EXTRUSION
INTERIOR (FEMALE)
[9422A]
WIPER GASKET
[7800VGR]
HEAD/JAMB EXTRUSION
EXTERIOR (MALE)
[9415A]
--
EXTRUDED ALUMINUM
SPLICE BAR
[9495A]
II,
3" OUTSIDE CORNER
INTERIOR (FEMALE)
[9432A]
OUTSIDE CORNER
EXTERIOR (MALE)
[9425A]
COMMERCIAL &
INDUSTRIAL
11
3 EXTRUSIONS
CI-CF-3-EXT
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
4" BASE EXTRUSION
[9404A]
WI PER GASKET
[7800VGR]
EXTRUDED ALUMINUM
SPLICE BAR
[9495A]
4" HEAD/JAMB EXTRUSION
INTERIOR (FEMALE)
[9423A]
HEAD/JAMB EXTRUSION
EXTERIOR (MALE)
[9415A]
-=
4' STACK JOINT
EXTRUSION
[9459A]
II,
4" OUTSIDE CORNER
INTERIOR (FEMALE)
[9433A]
4" SILL EXTRUSION
[9412A]
OUTSIDE CORNER
EXTERIOR (MALE)
[9429A]
COMMERCIAL &
INDUSTRIAL
11
4 EXTRUSIONS
CI-CF-4-EXT
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
NEW PENETRANT
(INSTALL THROUGH CUTOUT)
PANEL CUTOUT
(1/2' MINIMUM CLEARANCE
AROUND PENETRANT)
EXPANDABLE FOAM
(NOT BY PANEL MANUFACTURER)
: ~ ·.
WALL SUPPORT
NEW PENETRANT IN EXISTING WALL
SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION
COMMERCIAL &
INDUSTRIAL
PIPE PENETRATIONFIELD OF PANEL
CI-CF-PEN-1
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
PANEL CUTOUT
(EXTEND AS A SLOT
TO THE PANEL EDGE)
EXISTING PENETRANT
. . , ..
WALL SUPPORT
SLIDE PANEL TO FIT
AROUND PENETRANT
NEXT WALL PANEL
EXISTING PENETRANT IN NEW WALL
PANEL CUTOUT
EXISTING PENETRANT
EXPANDABLE FOAM
(NOT BY PANEL MANUFACTURER)
WALL SUPPORT
SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS
SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION
COMMERCIAL &
INDUSTRIAL
PIPE PENETRATIONNOTCHED PANEL
CI-CF-PEN-2
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
NEW PENETRANT
PANEL CUTOUT
(1/2" MIN. CLEARANCE
AROUND PENETRANT)
EXPANDABLE FOAM
(NOT BY PANEL MANUFACTURER)
WALL SUPPORT
PANEL JOINT
NEW PENETRATION IN EXISTING WALL AT PANEL JOINTS
SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS
COMMERCIAL &
INDUSTRIAL
PIPE PENETRATIONAT PANEL JOINT
CI-CF-PEN-3
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
EXTERIOR URETHANE
JOINT SEALANT
(TO TOP OF WALL)
r ......................
EXTERIOR WEATHER SEAL (NEW PENETRANT, EXISTING WALL)
BUTYL SEALANT
COVER PLATE
SEALANT LOCATION
-
........
,.--
-------------l/1
PANEL CUTOUT
.·-:·
. .
~
.. .
_____)
..-: ..
SEAL JOINT CAVITY
AT TOP & BOTIOM
~OFCUTOUT
BUTYL SEALANT
INTERIOR AIR/VAPOR SEAL (NEW PENETRANT, EXISTING WALL)
COMMERCIAL &
INDUSTRIAL
PIPE PENETRATIONWEATHER SEALS AT JOINT
CI-CF-PEN-4
DATE: 12-16-2015
METL
SPAN•
A Divioion of NCI Grou,, I no.
PENETRANT
WALL PANEL
BOTTOM COVER PLATE
BOTTOM COVER PLATE INSTALLATION
RIVET OR SCREW
(TYP)
URETHANE SEALANT
bl
WALL PANEL
BOTTOM COVER PLATE
TOP COVER PLATE INSTALLATION
EXPOSED URETHANE SEALANT
3/8" (MIN) FILLET
WALL PANEL
COVER PLATE ASSEMBLY
PENETRATION PERIMETER SEAL
COMMERCIAL &
INDUSTRIAL
PIPE PENETRATION- FLASHING
CI-CF-PEN-5
DATE: 12-16-2015
METL
SPAN•
STRUCTURAL
A Divioion of NCI Grou,, I no.
WALL SUPPORT
WALL PANEL
PANEL CUTOUT (AT CENTER OF PANEL)
STRUCTURAL
WALL SUPPORT
PANEL CUTOUT (AT PANEL JOINT)
STRUCTURAL
EXPANDABLE FOAM
(NOT BY PANEL MANUFACTURER)
WALL PANEL
FILLER INSULATION
COMMERCIAL &
INDUSTRIAL
BEAM PENETRATION
CI-CF-PEN-6
DATE: 12-16-2015
METL
SPAN•
RIVET OR SCREW
(TYP)
A Divioion of NCI Grou,, I no.
LEFT
COVER
PLATE
RIGHT
COVER
PLATE
COVER PLATE
2'
Lap Area
WALL PANEL
COVER PLATE LAYOUT
RIGHT COVER PLATE INSTALLATION
STRUCTURAL
COVER PLATE
WALL PANEL
LEFT COVER PLATE INSTALLATION
STRUCTURAL
WALL PANEL
PENETRATION PERIMETER SEAL
COMMERCIAL &
INDUSTRIAL
BEAM PENETRATION - FLASHING
CI-CF-PEN-7
DATE: 12-16-2015

Similar documents