WI - Metl-Span
Transcription
WI - Metl-Span
~----------------~ METL SPAN• A Divioion of NCI Grou,, I no. DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers and associated sealants shown in these details is based on standard design practices for commercial industrial applications for most U.S. and Canadian climatic zones. The default vapor barrier location is on the warm side in winter (the interior side of the panels). For projects located in extremely cold climates, exposed to high wind-driven rain or unusual interior conditions (sustained temperatures below 65°f), it may be advisable to modify the vapor barrier (joint sealant) location, or to add optional exterior joint sealants. It is the sole responsibility of the project architect to verity vapor barrier location. insulation required by code and HVAC equipment/ventilation requirements to allow proper air flow and the prevention of condensation. It is also the sole responsibility of the project architect to determine project-specific design loads. Meti-Span Technical Services is available to verity allowable panel spans and fastening requirements when provided with this information. The details contained herein show side joint fastening only. Please contact Meti-Span technical services for project-specific fastening requirements. All structural supports are shown for clarity only, and are not provided by Meti-Span. COMMERCIAL & INDUSTRIAL DISCLAIMER CI-CF-INF0-1 DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. Butyl caulk: For commerical/industrial projects the caulk is usually applied to the interior joint female pocket (see DISCLAIMER). Butyl caulk is also used to create ~~marriage beads .. which tie the panel sidejoint vapor seals to panel endjoint vapor seals. Butyl caulk is considered II non-skinning .. , which means it stays soft, flexible, and does not harden. Butyl caulk is for unexposed areas only, and cannot be used where it will be exposed to weather or sunlight Butyl sealant tape: Applied between flashings and panels to form a weathertight seal. All fasteners penetrating the flashing must be inserted through the sealant tape. Urethane caulk: Used in lieu of butyl sealant where there is exposure to the elements. It is recommended for lapped trims, exposed perimeter seals at framed openings or to seal between different construction materials, such as metal to concrete. Panel fasteners: Insulated metal panel fasteners are generally either self-drilling/self-tapping (also known as TEK screws), or self-tapping (also known as B point screws). TEK Fasteners contain a built-in drill point, and do not require pre-drilling. They are the quickest and easiest way to attach panels to light-medium gauge supports. B Point fasteners require a two-step operation: First holes are pre-drilled into the panel and structural support with an appropriate sized bit, then the fastener is inserted into the hole and tightened. B points are typically used to attach panels to medium-heavy gauge supports that are not penetrable by TEK fasteners. It is important that the pre-drilled holes are sized correctly for the fasteners to achieve proper pullout values. Bulb-lite® Rivets: Are similar to expansion fasteners, and are used where back fastening of the panels to structural supports is required. Holes must be pre-drilled with a 5/16 .. diameter. The grip range of the rivets must be matched to the thickness of the structural support to ensure proper fastening. COMMERCIAL & INDUSTRIAL SEALANTS & FASTENERS CI-CF-INF0-2 12-16-2015 METL SPAN• A Divioion of NCI Grou,, 1no. ~-----------J~-----------Jr-~----------~r------------~J~ CF-42, CF-36 FLUTE/MESA ;;00 ~·~ ~------~~--------~? CF-42, CF-36, CF30 MESA/MESA -~--r~__E_E~-0----------------------~~~~--------------------------------~~~ CF-36A, CF-30A ARCHITECTURAL FLAT/MESA ,;;··· ~·~ ~------------------------~------------------------------~? CF-36, CF-42 SANTA FE £_~_~EEND------~~--------~~? CF-42, CF-36, CF-30 STRIATED/MESA COMMERCIAL & INDUSTRIAL PANEL PROFILES CI-CF-JT -01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, 1no. 36" 7.2 INSUL-RIB J \_/,...---......--\_) \_/ 36" LS 36 1~ '' . -~ """ ' . """ ' . """ "0 . """ ' . """ CF-36, CF-42 TUFF-CAST, TUFF-WALL COMMERCIAL & INDUSTRIAL PANEL PROFILES ' . """ 0 . 0) CI-CF-JT -02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP WI 1/4" HWH FASTENERS @ EACH WALL SUPPORT INTERIOR WALL SUPPORT CLIP AND FASTENER ASSEMBLY JOINT SEALANT WALL SUPPORT INTERIOR OPTIONAL JOINT SEALANT SEE DETAIL "A" JOINT SEALANT APPLICATION NON-SKINNING BUTYL SEALANT 1/4" UNIFORM BEAD MIN. @LOCATION SPECIFIED OPTIONAL JOINT SEALANT INTERIOR DETAIL A WALL SUPPORT 1/B" MAX@ JOINT COMMERCIAL & INDUSTRIAL CF PANEL JOINT DETAILS CI-CF-JT -03 DATE: 12-16-2015 INTERIOR SURFACE METL SPAN• A Divioion of NCI Grou,, I no. ./ ./ ./ ./ EXTERIOR SURFACE WALL SUPPORT 14 GA. CLIP 1/4" HWH FASTENERS WALL SUPPORT (14GA. MINIMUM) PANEL CLIP @ EACH WALL SUPPORT COMMERCIAL & INDUSTRIAL ATTACHMENT- SIDEJOINTPRE-ENGINEERED SUPPORT CI-CF-FSTN-01A DATE: 12-16-2015 INTERIOR SURFACE METL SPAN• A Divioion of NCI Grou,, I no. EXTERIOR SURFACE STRUCTURAL STEEL STRUCTURAL STEEL 14 GA. CLIP 1/4" HWH FASTENERS I I I I I I I I I I I I 14 GA. CLIP W/FASTENERS COMMERCIAL & INDUSTRIAL ATTACHMENT- SIDEJOINTSTRUCTURALSTEELSUPPORT CI-CF-FSTN-01 B DATE: 12-16-2015 METL SPAN• 2 HOLE GIRT CLIP A Divioion of NCI Grou,, I no. DOME HEAD BULB-TITE® RIVETS * INSTALL THROUGH GIRT CLIPS INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL INTERIOR SIDE STRUCTURAL STEEL BULB-TITE® RIVET GIRT CLIP 14 GA. CLIP GIRT CLIP 1/4" HWH BULB-TITE® RIVET FASTENERS STRUCTURAL STEEL COMMERCIAL & INDUSTRIAL ATTACHMENT- BACK FASTENED WI GIRT CLIPS CI-CF-FSTN-01 C DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. DOME HEAD BULB-TITE® RIVETS * INSTALL THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH STEEL INTERIOR SIDE WALL SUPPORT 14 GA. CLIP BULB-TITE® RIVET 1/4" HWH FASTENERS WALL SUPPORT I I BULB-TITE® RIVET I I I I I I I I I 14 GA. CLIP W/FASTENERS COMMERCIAL & INDUSTRIAL ATTACHMENT- BACK FASTENED WI RIVETS CI-CF-FSTN-01 D DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. (FP1) FASTENING PATTERN 1 SIDE JOINT FASTENING DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" (FP2) FASTENING PATTERN 2 SIDE JOINT FASTENING AND ONE DOME HEAD BULB-TITE® RIVET INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) COMMERCIAL & INDUSTRIAL FASTENING PATTERNS CI-CF-FP 1-2 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" 10.5" (FP3) FASTENING PATTERN 3 SIDE JOINT FASTENING AND TWO DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" 10.5" 10.5'' (FP4) FASTENING PATTERN 4 SIDE JOINT FASTENING WITH THREE DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) COMMERCIAL & INDUSTRIAL FASTENING PATTERNS CI-CF-FP 3-4 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. DIMENSION IS FROM FEMALE EDGE +/- 1.5" 5.25" 10.5'' 10.5" 10.5" 5.25" (FP5) FASTENING PATTERN 5 SIDE JOINT FASTENING AND BACK FASTENING WITH FOUR DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" (FP6) FASTENING PATTERN 6 SIDE JOINT FASTENING AND ONE GIRT CLIP WITH TWO DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) COMMERCIAL & INDUSTRIAL FASTENING PATTERNS CI-CF-FP 5-6 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" 10.5" (FP7) FASTENING PATTERN 7 SIDE JOINT FASTENING AND TWO GIRT CLIPS WITH FOUR DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL DIMENSION IS FROM FEMALE EDGE +/- 1.5" 10.5" 10.5" 10.5'' (FP8) FASTENING PATTERN 8 SIDE JOINT FASTENING WITH THREE GIRT CLIPS WITH SIX DOME HEAD BULB-TITE® RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) COMMERCIAL & INDUSTRIAL FASTENING PATTERNS CI-CF-FP 7-8 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 8.4" 8.4" 8.4" 8.4" 8.4" (FP9) FASTENING PATTERN 9 WITH FOUR SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER 8.4" - 8.4" 8.4" - - - - - 8.4" 8.4" - - - ~~ (FP1 0) - - - I ~ FASTENING PATTERN 10 WITH FIVE SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) COMMERCIAL & INDUSTRIAL FASTENING PATTERNS CI-CF-FP 9-10 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATTACHMENT (NOT BY PANEL MANUFACTURER} 1/4" HWH CLIP FASTENERS [SEE CHART] BUYTL SEALANT [7100BWH] BASE TRIM [F3369] #12 PANCAKE STITCH FASTENER [12A] 1/8" Q> RIVETS @ 12"0.C. [14] FINISH FLOOR CONC. FASTENERS (NOT BY PANEL MANUFACTURER) BASE FLASHING [SEE CHART] BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] 4 <C1 <1 CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] BUTYL SEALANT [7100BWH] URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE FLASHING TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5001 1616PNC 1724PNC 1816PNC 2.5" F5013 1624PNC 1732PNC 1824PNC 2.75" F5071 1624PNC 1732PNC 1824PNC 3" F5034 F5050 1624PNC 1732PNC 1632PNC 1740PNC 1824PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL BASE - OVERHANG WI NOTCHED SLAB CI-CF-BE-02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATTACHMENT (NOT BY PANEL MANUFACTURER) 1/4" HWH CLIP FASTENERS [SEE CHART] BUYTL SEALANT [7100BWH] #12 PANCAKE STITCH FASTENER [12A] 1/8" !II RIVETS @ 12"0.C. [14] FINISH FLOOR CONC. FASTENERS (NOT BY PANEL MANUFACTURER) BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] BASE FLASHING [SEE CHART] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] BUTYL SEALANT [7100BWH] <J URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE FLASHING TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5002 1616PNC 1724PNC 1816PNC 2.5" F5014 1624PNC 1732PNC 1824PNC 2.75" F5072 1624PNC 1732PNC 1824PNC 3" F5032 F5053 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL WI BASE - OVERHANG NOTCHED SLAB- ALT. CI-CF-BE-04 DATE: 3-17-2016 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATIACHMENT (NOT BY PANEL MANUFACTURER) 1/4" HWH CLIP FASTENERS [SEE CHART] BUTYL SEALANT [7100BWH] BASE TRIM [F3369] #12 PANCAKE STITCH FASTENER [12A] 1/8" 16 RIVETS @ 12"0.C. [14] FINISH FLOOR CONC. FASTENERS (NOT BY PANEL MANUFACTURER) BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] BASE FLASHING [SEE CHART] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] BUTYL SEALANT [7100BWH] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE FLASHING TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5001 1616PNC 1724PNC 1816PNC 2.5" F5013 1624PNC 1732PNC 1824PNC 2.75" F5071 1624PNC 1732PNC 1824PNC 3" F5034 F5050 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL BASE - OVERHANG WI DRIP TRIM CI-CF-BE-06 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATIACHMENT (NOT BY PANEL MANUFACTURER) BUTYL SEALANT [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR 1/8" ~ RIVETS @8"0.C. [14] CONC. FASTENERS (NOT BY PANEL MANUFACTURER) BASE FLASHING [SEE CHART] BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] BUTYL SEALANT [7100BWH] PANEL SUPPORT ANGLE (NOT BY PANEL MANUFACTURER) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE FLASHING TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE B CLIP FASTENER 2" F5076 1616PNC 1724PNC 1816PNC 2.5" F5077 1624PNC 1732PNC 1824PNC 2.75" F5078 1624PNC 1732PNC 1824PNC 3" F5079 F5080 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL BASE - OVERHANG WI EDGE TRIM CI-CF-BE-07 DATE: 01-14-2016 METL SPAN• - A Divioion of NCI Grou,, I no. r- -r T -TV- ,14 GA. PANEL CLIP [4633GNC] ~ 1 ~! 1/4" HWH CLIP FASTENERS [SEE CHART] ~ ~ ~~ / BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] ~---::1) 1 CONTINUOUS BASE ATIACHMENT (NOT BY PANEL MANUFACTURER) / I-,.. I FINISH FLOOR ~ I 1/8" !II RIVETS @S"O.C. ~ . v ~ D [14] BASE FLASHING : Ll ~ L...J...._:;;;;;;;;~'Jif:J· [SEE CHART] Ll CONC. FASTENERS (NOT BY PANEL MANUFACTURER) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE FLASHING TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE B CLIP FASTENER 2" F5076 1616PNC 1724PNC 1816PNC 2.5" F5077 1624PNC 1732PNC 1824PNC 2.75" F5078 1624PNC 1732PNC 1824PNC 3" F5079 1624PNC 1732PNC 1824PNC 4" F5080 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL BASE - OVERHANG WI BASE SUPPORT CI-CF-BE-08 DATE: 2-25-2016 METL SPAN• A Divioion of NCI Grou,, I no. FIELD NOTCH HEM(S} AS REQUIRED (2) BEADS URETHANE SEALANT ~~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP BASE CI-CF-EL-8 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATTACHMENT (NOT BY PANEL MANUFACTURER) BUYTL SEALANT [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] #12 PANCAKE STITCH FASTENER [12A] WI PER GASKET [7800VGR] FINISH FLOOR CONC. FASTENERS (NOT BY PANEL MANUFACTURER) FIELD DRILL 3/8" ¢ MIN. WEEP HOLES @ 24" o.c. BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] BASE EXTRUSION [SEE CHART] SPLICE BAR [9495A] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] BUTYL SEALANT [7100BWH] URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE EXTRUSION TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 9404A 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL WI BASE - OVERHANG NOTCHED SLAB, EXTRUSION CI-CF-EB-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] CONTINUOUS BASE ATIACHMENT (NOT BY PANEL MANUFACTURER) 1/4" HWH CLIP FASTENERS [SEE CHART] BUTYL SEALANT [7100BWH] #12 PANCAKE STITCH FASTENER [12A] WIPER GASKET [7800VGR] FINISH FLOOR BASE EXTRUSION [SEE CHART] CONC. FASTENERS (NOT BY PANEL MANUFACTURER) FIELD DRILL 3/8" f/J MIN. WEEP HOLES @24" o.c. BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] SPLICE PLATE [9495A] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71008WH] BUTYL SEALANT [71 OOBWH] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE EXTRUSION TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 9404A 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC 4" COMMERCIAL & INDUSTRIAL BASE - OVERHANG WI EXTRUSION CI-CF-EB-02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. CORNER TRIM [F5140] 1/4" PANCAKE FASTENER @ EACH SUPPORT [SEE CHART] 1/8" 0 RIVETS @B"O.C. [14] BUTYL SEALANT [7100BWH] SEALANT TAPE (AS REQUIRED) EXPANDABLE FOAM INSULATION (NOT BY PANEL MANUFACTURER) CORNER TRIM [SEE CHART] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F5102 1424PNC 2.5" F5103 1432PNC 2.75" F5105 1432PNC 3" F5104 F5101 1432PNC 4" COMMERCIAL & INDUSTRIAL 1440PNC OUTSIDE CORNER WI FLUSH TRIM CI-CF-CE-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 1/8" 16 RIVETS @SUPPORTS 1/8" 1/J RIVETS @8" [14] [14] BUTYL SEALANT [7100BWH] o.c. CORNER TRIM [F5140] 1/4" PANCAKE FASTENER @ EACH SUPPORT [SEE CHART] SEALANT TAPE (AS REQUIRED) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F5102 1424PNC 2.5" F5103 1432PNC 2.75" F5105 1432PNC 3" F5104 1432PNC 4" F5101 1440PNC COMMERCIAL & INDUSTRIAL INSIDE CORNER WI FLUSH TRIM CI-CF-CE-03 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. a.. :5 'ol C\J~ a: I-- FIELD NOTCH HEM(S) AS REQUIRED a.. (2) BEADS URETHANE SEALANT :5 a: I-- NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP CORNER CI-CF-EL-C DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. IV Atl. . .~ I::::M SUPPORTS FEMALE CORNER EXTRUSION [9430A] BUTYL SEALANT [7100BWH] #12 PANCAKE STITCH FASTENER @ EACH SUPPORT WI PER GASKET [7800VGR] [12A] 1/4" PANCAKE FASTENER @ EACH SUPPORT [SEE CHART] BUTYL SEALANT [7100BWH] FIELD MITER PANEL MALE CORNER EXTRUSION [9425A] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER EXTRUSION FEMALE CORNER EXTRUSION PANCAKE HEAD TYPE3 2" 9425ANC 9430ANC 1424PNC 2.5" 9425ANC 9431ANC 1432PNC 3" 9425ANC 9432ANC 1432PNC 4" 9429ANC 9433ANC 1440PNC COMMERCIAL & INDUSTRIAL WI OUTSIDE CORNER TWO PIECE EXTRUSION CI-CF-EC-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. MALE CORNER EXTRUSION [SEE CHART] #12 PANCAKE STITCH FASTENER @ EACH SUPPORT [12A] BUTYL SEALANT [7100BWH] BUTYL SEALANT [7100BWH] FEMALE CORNER EXTRUSION [SEE CHART] 1/4" PANCAKE FASTENER @EACH SUPPORT [SEE CHART] WIPER GASKET [7800GVR] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER EXTRUSION FEMALE CORNER EXTRUSION PANCAKE HEAD TYPE3 211 9435ANC 9440ANC 1424PNC COMMERCIAL & INDUSTRIAL WI INSIDE CORNER TWO PIECE EXTRUSION CI-CF-EC-02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] 14 GA. PANEL CLIP [4633GNC] 1/4" HWH CLIP FASTENERS [SEE CHART] BUTYL SEALANT [7100BWH] EXTERIOR HEAD TRIM [F5044] #12 PANCAKE STITCH SCREW [12A] URETHANE SEALANT [HW540] 1/8" ~ SUPPORT POP RIVET 8" D.C. [14] WINDOW /DOOR/LOUVER/FRAM lNG (NOT BY PANEL MANUFACTURER) INTERIOR HEAD TRIM [SEE CHART] URETHANE SEALANT [HW540] PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR HEAD TRIM TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5045 1616PNC 1724PNC 1816PNC 2.5" F5046 1624PNC 1732PNC 1824PNC 2.75" F5047 1624PNC 1732PNC 1824PNC 3" F5048 1624PNC 1732PNC 1824PNC 4" F5049 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL HEAD W/ TWO PIECE TRIM CI-CF-HD-01 DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] 14 GA. PANEL CLIP [4633GNC] BUTYL SEALANT [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] #12 PANCAKE STITCH SCREW [12Al EXTERIOR HEAD TRIM [F5044] SUPPORT HEAD TRIM (OPTIONAL) URETHANE SEALANT [HW540] 1/8" ~ URETHANE SEALANT [HW540] POP RIVET 8" O.C. [14] INTERIOR HEAD TRIM [SEE CHART] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR HEAD TRIM TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5045 1616PNC 1724PNC 1816PNC 2.5" F5046 1624PNC 1732PNC 1824PNC 2.75" F5047 1624PNC 1732PNC 1824PNC 3" F5048 1624PNC 1732PNC 1824PNC 4" F5049 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL O.H. DOOR HEAD WI TWO PIECE TRIM CI-CF-HD-02 DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT -----..,.~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP TWO PIECE HEAD CI-CF-EL-H DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. INTERIOR HEAD EXTRUSION [SEE CHART] 14 GA. PANEL CLIP [4633GNC] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] 1/4" HWH CLIP FASTENERS [SEE CHART] BUTYL SEALANT [7100BWH] WIPER GASKET [7BOOVGR] #12 PANCAKE STITCH SCREW [12A] EXTERIOR HEAD EXTRUSION [9415A] FIELD DRILL 3/8" ¢ MIN. WEEP HOLES @ 24" o.c. SUPPORT URETHANE SEALANT [HW540] WIN DOW/DOOR/LOUVER/FRAMING (NOT BY PANEL MANUFACTURER) PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD EXTRUSION TYPE 3 CLIP FASTENER TYPE 5 CLIP FASTENER TYPE B CLIP FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL HEAD W/ TWO PIECE EXTRUSION CI-CF-EH-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. INTERIOR HEAD EXTRUSION [SEE CHART] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] 14 GA. PANEL CLIP [4633GNC] BUTYL SEALANT [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] #12 PANCAKE STITCH SCREW [12A] WI PER GASKET [7800VGR] EXTERIOR HEAD EXTRUSION [9415A] SUPPORT HEAD TRIM (OPTIONAL) FIELD DRILL 3/8" ¢ MIN. WEEP HOLES @ 24" O.C. URETHANE SEALANT [HW540] PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD EXTRUSION TYPE 3 CLIP FASTENER TYPE 5 CLIP FASTENER TYPE B CLIP FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL WI O.H. DOOR HEAD TWO PIECE EXTRUSION CI-CF-EH-02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. SUPPORT WINDOW/LOUVER/DOOR/FRAMING (NOT BY PANEL MANUFACTURER) 1/4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) [SEE CHART] BUTYL SEALANT [7100BWH] INTERIOR JAMB TRIM [SEE CHART] BUTYL SEALANT [7100BWH] PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) URETHANE SEALANT [HW540] BUTYL TAPE [7300BGR] 1/8" Ill POP RIVET 8" O.C. [14] 1/8" Ill RIVETS @8"0.C. URETHANE SEALANT [HW540] [14] EXTERIOR JAMB TRIM [F27] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F5442 1424PNC 2.511 2.7511 F5442 1432PNC F5442 1432PNC 311 F5443 1432PNC 411 FF443 1440PNC COMMERCIAL & INDUSTRIAL JAMB W/ TWO PIECE TRIM CI-CF-JB-01 DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. SUPPORT WINDOW/LOUVER/DOOR/FRAMING (NOT BY PANEL MANUFACTURER) BUTYL SEALANT [7100BWH] 1/4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) [SEE CHART] BUTYL SEALANT [7100BWH] PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) BUTYL TAPE [7300BGR] 1/8" riJ RIVETS @B"O.C. [14] FLAT JAMB TRIM [SEE CHART] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FLAT JAMB TRIM PANCAKE HEAD TYPE3 211 F5390 1424PNC 2.511 2.7511 F5392 1432PNC F5394 1432PNC 311 F5396 1432PNC 411 F5398 1440PNC COMMERCIAL & INDUSTRIAL JAMB W/ DEEP TRIM CI-CF-JB-02 DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP TWO PIECE JAMB CI-CF-EL-J DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. SUPPORT WINDOW/LOUVER/DOOR/FRAM lNG (NOT BY PANEL MANUFACTURER) 1/4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) [SEE CHART] #12 PANCAKE STITCH SCREW@ ENDS [12A] BUTYL SEALANT [7100BWH] BUTYL SEALANT [7100BWH] PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) URETHANE SEALANT [HW540] WIPER GASKET [7800VGR] FEMALE JAMB EXTRUSION [SEE CHART] BUTYL SEALANT [7100BWH] MALE JAMB EXTRUSION [9415A] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE JAMB EXTRUSION TYPE 3THRU FASTENER TEK5THRU FASTENER TYPE BTHRU FASTENER 211 9420A 1424PNC 1732PNC 1824PNC 2.511 311 9421A 1432PNC 1740PNC 1832PNC 9422A 1432PNC 1740PNC 411 9423A 1440PNC 1748PNC 1832PNC 1832PNC COMMERCIAL & INDUSTRIAL JAMB W/ EXTRUSION CI-CF-EJ-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. SUPPORT 1/4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) [SEE CHART] JAMB WRAP TRIM (OPTIONAU BUTYL SEALANT [71 OOBWH] INTERIOR JAMB TRIM [SEE CHART] BUTYL SEALANT [71 OOBWH] URETHANE SEALANT [HW540] 1/8" ~ POP RIVET @8"0.C. [14] BUTYL TAPE [71 OOBWH] URETHANE SEALANT [HW540] 1/8" ~ RIVETS @8" o.c. [14] EXTERIOR JAMB TRIM [F27] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F5442 1424PNC 2.511 311 F5442 1432PNC F5443 1432PNC 411 F5443 1440PNC COMMERCIAL & INDUSTRIAL O.H. DOOR JAMB WI TWO PIECE TRIM CI-CF-DJ-01 DATE: 01-14-2016 METL SPAN• A Divioion of NCI Grou,, I no. SUPPORT 1/4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) [SEE CHART] JAMB WRAP TRIM ~ (OPTIONAU #12 PANCAKE STITCH SCREW@ ENDS [12A] BUTYL SEALANT [7100BWH] BUTYL SEALANT [7100BWH] URETHANE SEALANT [HW540] FEMALE JAMB EXTRUSION [SEE CHART] WIPER GASKET [7800VGR] MALE JAMB EXTRUSION [9415A] BUTYL SEALANT [7100BWH] REFER TO SHEET 11 CI-CF-INF011 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE JAMB EXTRUSION TYPE 3THRU FASTENER TEK5THRU FASTENER TYPE BTHRU FASTENER 211 9420A 1424PNC 1732PNC 1824PNC 2.511 311 9421A 1432PNC 1740PNC 1832PNC 9422A 1432PNC 1740PNC 411 9423A 1440PNC 1748PNC 1832PNC 1832PNC COMMERCIAL & INDUSTRIAL O.H. DOOR JAMB WI EXTRUSION CI-CF-ED-01 DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. #12 PANCAKE STITCH SCREW @ 12" O.C. / PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) tr======='lf SILL TRIM (SEE CHART] ~ 1/8" ~ RIVETS @8" O.C. [14] FLASHING SEALANT TAPE [7405BWH] A 1 I. SUPPORT ~ ~ WINDOW/LOUVER/DOOR/FRAM lNG (NOT BY PANEL MANUFACTURER) Rl··-~ ~' '== ~ CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT = [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL TRIM TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5501 1616PNC 1724PNC 1816PNC 2.5" F5503 1624PNC 1732PNC 1824PNC 2.75" - 3" F5507 1624PNC 1624PNC 1732PNC 1732PNC 1824PNC 1824PNC 4" F5509 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL SILL DETAIL WI FLAT TRIM CI-CF-SL-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP SILL CI-CF-EL-S DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. #12 PANCAKE STITCH SCREW @ 12"0.C. WINDOW/LOUVER/DOOR/FRAMING / PERIMETER SEALANT (NOT BY PANEL MANUFACTURER) tr======='ll' SILL EXTRUSION [SEE CHART] I (NOT BY PANEL MANUFACTURER) SUPPORT ~ +-------llr-.---,--~-------=--..J~I ~ BUTYL SEALANT [7100BWH] ~ '== WIPER GASKET [7800VGR] CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT = [7100BWH] 1/4" HWH CLIP FASTENERS [SEE CHART] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL EXTRUSION TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" 9413A 1616PNC 1724PNC 1816PNC 2.5" 9413A 1624PNC 1732PNC 1824PNC 3" 9413A 1624PNC 1732PNC 1824PNC 4" 9412A 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL SILL DETAIL WI EXTRUSION CI-CF-ES-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. URETHANE END DAM ® INTERIOR HEAD TRIM WITH TABS BENT DOWN URETHANE SEALANT @ EXTERIOR HEAD TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP @SILL TRIM WITH TABS BENT UP @ EXTERIOR JAMB TRIM BUTYL SEALANT FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXPOSED SEALANT (NOT BY PANEL PANEL MANUFACTURER) CD INTERIOR JAMB TRIM TRIM INSTALLATION SEQUENCE: CD INTERIOR JAMB TRIMS ®INTERIOR HEAD TRIM WITH TABS BENT DOWN (NOTCHED) @SILL TRIM WITH TABS BENT UP (NOTCHED) @ EXTERIOR JAMB TRIMS @ EXTERIOR HEAD TRIM COMMERCIAL & INDUSTRIAL TRIM LAPS AT FRAMED OPENING CI-CF-T-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. URETHANE END DAM URETHANE END DAM ®INTERIOR HEAD EXTRUSION @)EXTERIOR HEAD EXTRUSION 3/8" 0 WEEP HOLES @EXTERIOR JAMB EXTRUSION BUTYL SEALANT EXPOSED SEALANT (NOT BY PANEL PANEL MANUFACTURER) @SILL EXTRUSION CD INTERIOR JAMB EXTRUSION EXTRUSION INSTALLATION SEQUENCE: d) INTERIOR JAMB EXTRUSIONS (g) INTERIOR HEAD EXTRUSION (NOTCHED) @SILL EXTRUSION (NOTCHED) @ EXTERIOR HEAD EXTRUSION (NOTCHED) @ EXTERIOR JAMB EXTRUSIONS COMMERCIAL & INDUSTRIAL EXTRUSION AT FRAMED OPENING CI-CF-E-01 DATE: 12-16-2015 METL SPAN• 1.. . 1 T - A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP [4633GNC] ~ 1/4" HWH CLIP FASTENERS [SEE CHART] ~ BASE TRIM @8" O.C. [14] ~t 1 CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] l [~~~ 1/8" Ill RIVET #12 PANCAKE STITCH SCREW [12A] ~ t 0~ 11$1111 .~ . ~ * +-----I~ SR ~ rl SUPPORT /-= - WORK ~t=====---r;::;: f ~~~ ~~: STACK JOINT TRIM [SEE CHART] fi FLASHING SEALANT TAPE [7405BWH] ~ ~ POINT~ ELEV 1 CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] I FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT TRIM TYPE 3 CLIP FASTENER TYPES CLIP FASTENER TYPE BCLIP FASTENER 2" F5701 1616PNC 1724PNC 1816PNC 2.5" F5703 1624PNC 1732PNC 1824PNC 2.75" - 1624PNC 1732PNC 1824PNC 3" F5707 1624PNC 1732PNC 1824PNC 4" F5709 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL STACK JOINT WI TRIM CI-CF-SJ-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT NOTE: POP RIVET OR STITCH SCREW AS NECESSARY COMMERCIAL & INDUSTRIAL TRIM END LAP STACK JOINT CI-CF-EL-SJ DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. 14 GA. PANEL CLIP ~ [4633GNC] 1/4" HWH CLIP FASTENERS [SEECHART] #12 PANCAKE STITCH FASTENER ~ ~: WIPER GASKET [ ] 7800GVR [12A] : ~ : ;"'-'{llM-~V _... I STACK JOINT EXTRUSION [SEE CHART] SEALANT [71 OOBWH] 1 1 1 ;;00 - - - - - - ' lrL..1-LW...__..._. ~ C')~ 11 ~ FIELD DRILl_3/B"• MIN. CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT dJ t / WEEP HOLES _ / @ 24" O.C. WIPER GASKET [7800GVR] :' ~ -=- ~~~~~==============~---~W~O~R~K~P~O~IN~T~J.~ >~ Ivr··i!j~E~ :/ ~ I ) URETHANE SEALANT [HW540] i : 1 I ' ELEV "17 SUPPORT CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] SPLICE BAR [9495A] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT EXTRUSION lYPE 3 CLIP FASTENER 1YPE5 CLIP FASTENER lYPE BCLIP FASTENER 2" 9455A 1616PNC 1724PNC 1816PNC 2.5" 9456A 1624PNC 1732PNC 1824PNC 3" 9458A 1624PNC 1732PNC 1824PNC 4" 9459A 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL STACK JOINT WI EXTRUSION CI-CF-ESJ-01 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. NOTE: THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. ALL ROOF COMPONENTS, PERIMETER FLASHING AND SEALANTS ARE NOT BY PANEL MANUFACTURER FLASHING SEALANT TAPE [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] INTERIOR AIR/VAPOR SEAL (NOT BY PANEL MANUFACTURER) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] 1/4" HWH CLIP FASTENERS [SEE CHART] 14 GA. PANEL CLIP [4633GNC] SUPPORT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE Ill CLIP FASTENER TYPEVCLIP FASTENER TYPE B CLIP FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL EAVE DETAILCONVENTIONAL ROOF CI-CF-VE-01 DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [7100BWH] ROOF MEMBRANE & PARAPET BLOCKING PARAPET CAP ------.. (NOT BY PANEL MANUFACTURER) (NOT BY PANEL MANUFACTURER) i,:::-------'7'-~---------- I I 1 1/4" HWH CLIP FASTENERS : [SEE CHART] --------.......~ 1 1 ~---------~ - ~ I "1--,-...-'{l••a 1 I I METAL CLEAT AND ) FORM OF ATTACHMENT _____/ (NOT BY PANEL MANUFACTURER) ~ I L ~ SUPPORT ~•~FE~ lr- ! 1 FASTENER (NOT BY PANEL MANUFACTURER) = I ~ ~ .. 14 GA. PANEL CLIP FLASHING SEALANT TAPE [7405BWH] . FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP FASTENER TYPE 5 CLIP FASTENER TYPE B CLIP FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 3" 1624PNC 1624PNC 1732PNC 1732PNC 1824PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL PARAPET(SUPPORTED) W/ TRIM CI-CF-TP-01 DATE: 12-16-2015 METL SPAN• - A Divioion of NCI Grou,, I no. CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] PARAPET EXTRUSION (NOT BY PANEL MANUFACTURER) ~ ROOF MEMBRANE & PARAPET CAP (NOT BY PANEL MANUFACTURER) F:::!!!!!==:'::r;r:~.,.., ~ rri!FT~,,_ PARAPET BLOCKING {NOT BY PANEL MANUFACTURER) _______ ~w~-!FW-~r~IJ!~~ -~~~-~-~~-~-=-=T_'-=_-; 1VAJ:•• ~=-~=t~ Iif'::\_5) SUPPORT 1/4" HWH CLIP FASTENERS [SEECHART] ~ = FASTENER (NOT BY PANEL MANUFACTURER) v:! 1 14 GA. PANEL CLIP _ _ / [4633GNC] ·. REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP FASTENER TYPE 5 CLIP FASTENER TYPE B CLIP FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 3" 4" 1624PNC 1732PNC 1824PNC 1632PNC 1740PNC 1832PNC COMMERCIAL & INDUSTRIAL PARAPET(SUPPORTED) WI EXTRUSION CI-CF-EP-02 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 2" BASE EXTRUSION [9405A] 2" STACK JOINT EXTRUSION [9455A] 2" BASE/SOFFIT EXTRUSION [9414A] 2" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9420A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- 2" VERTICAL H J O I N T l f EXTRUSION INTERIOR (FEMALE) [9450A] 2" VERTICAL H JOINT EXTRUSION II. ~t:!~?R (MALE) II =::::!!IHI!:::=:!-::!1' 1!!::-!!:::' WIPER GASKET [?BOOVGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 2" OUTSIDE CORNER INTERIOR (FEMALE) [9430A] INSIDE CORNER INTERIOR (MALE) [9435A] 2" SILL EXTRUSION [9413A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 2" INSIDE CORNER EXTERIOR (FEMALE) [9440A] COMMERCIAL & INDUSTRIAL 11 2 EXTRUSIONS CI-CF-2-EXT DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,. I no. 2.5" BASE EXTRUSION [9406A] 2.5" STACK JOINT EXTRUSION [9455A] 2.5" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9421A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- WIPER GASKET [7800VGR] 11 EXTRUDED ALUMINUM SPLICE BAR [9495A] 2.5" OUTSIDE CORNER INTERIOR (FEMALE) [9431A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] COMMERCIAL & INDUSTRIAL 11 2.5 EXTRUSIONS CI-CF-2.5-EXT DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 3" BASE EXTRUSION [9407A] 3" STACK JOINT EXTRUSION [9458A] 3" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9422A] WIPER GASKET [7800VGR] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- EXTRUDED ALUMINUM SPLICE BAR [9495A] II, 3" OUTSIDE CORNER INTERIOR (FEMALE) [9432A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] COMMERCIAL & INDUSTRIAL 11 3 EXTRUSIONS CI-CF-3-EXT DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. 4" BASE EXTRUSION [9404A] WI PER GASKET [7800VGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 4" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9423A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -= 4' STACK JOINT EXTRUSION [9459A] II, 4" OUTSIDE CORNER INTERIOR (FEMALE) [9433A] 4" SILL EXTRUSION [9412A] OUTSIDE CORNER EXTERIOR (MALE) [9429A] COMMERCIAL & INDUSTRIAL 11 4 EXTRUSIONS CI-CF-4-EXT DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. NEW PENETRANT (INSTALL THROUGH CUTOUT) PANEL CUTOUT (1/2' MINIMUM CLEARANCE AROUND PENETRANT) EXPANDABLE FOAM (NOT BY PANEL MANUFACTURER) : ~ ·. WALL SUPPORT NEW PENETRANT IN EXISTING WALL SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION COMMERCIAL & INDUSTRIAL PIPE PENETRATIONFIELD OF PANEL CI-CF-PEN-1 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. PANEL CUTOUT (EXTEND AS A SLOT TO THE PANEL EDGE) EXISTING PENETRANT . . , .. WALL SUPPORT SLIDE PANEL TO FIT AROUND PENETRANT NEXT WALL PANEL EXISTING PENETRANT IN NEW WALL PANEL CUTOUT EXISTING PENETRANT EXPANDABLE FOAM (NOT BY PANEL MANUFACTURER) WALL SUPPORT SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION COMMERCIAL & INDUSTRIAL PIPE PENETRATIONNOTCHED PANEL CI-CF-PEN-2 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. NEW PENETRANT PANEL CUTOUT (1/2" MIN. CLEARANCE AROUND PENETRANT) EXPANDABLE FOAM (NOT BY PANEL MANUFACTURER) WALL SUPPORT PANEL JOINT NEW PENETRATION IN EXISTING WALL AT PANEL JOINTS SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS COMMERCIAL & INDUSTRIAL PIPE PENETRATIONAT PANEL JOINT CI-CF-PEN-3 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. EXTERIOR URETHANE JOINT SEALANT (TO TOP OF WALL) r ...................... EXTERIOR WEATHER SEAL (NEW PENETRANT, EXISTING WALL) BUTYL SEALANT COVER PLATE SEALANT LOCATION - ........ ,.-- -------------l/1 PANEL CUTOUT .·-:· . . ~ .. . _____) ..-: .. SEAL JOINT CAVITY AT TOP & BOTIOM ~OFCUTOUT BUTYL SEALANT INTERIOR AIR/VAPOR SEAL (NEW PENETRANT, EXISTING WALL) COMMERCIAL & INDUSTRIAL PIPE PENETRATIONWEATHER SEALS AT JOINT CI-CF-PEN-4 DATE: 12-16-2015 METL SPAN• A Divioion of NCI Grou,, I no. PENETRANT WALL PANEL BOTTOM COVER PLATE BOTTOM COVER PLATE INSTALLATION RIVET OR SCREW (TYP) URETHANE SEALANT bl WALL PANEL BOTTOM COVER PLATE TOP COVER PLATE INSTALLATION EXPOSED URETHANE SEALANT 3/8" (MIN) FILLET WALL PANEL COVER PLATE ASSEMBLY PENETRATION PERIMETER SEAL COMMERCIAL & INDUSTRIAL PIPE PENETRATION- FLASHING CI-CF-PEN-5 DATE: 12-16-2015 METL SPAN• STRUCTURAL A Divioion of NCI Grou,, I no. WALL SUPPORT WALL PANEL PANEL CUTOUT (AT CENTER OF PANEL) STRUCTURAL WALL SUPPORT PANEL CUTOUT (AT PANEL JOINT) STRUCTURAL EXPANDABLE FOAM (NOT BY PANEL MANUFACTURER) WALL PANEL FILLER INSULATION COMMERCIAL & INDUSTRIAL BEAM PENETRATION CI-CF-PEN-6 DATE: 12-16-2015 METL SPAN• RIVET OR SCREW (TYP) A Divioion of NCI Grou,, I no. LEFT COVER PLATE RIGHT COVER PLATE COVER PLATE 2' Lap Area WALL PANEL COVER PLATE LAYOUT RIGHT COVER PLATE INSTALLATION STRUCTURAL COVER PLATE WALL PANEL LEFT COVER PLATE INSTALLATION STRUCTURAL WALL PANEL PENETRATION PERIMETER SEAL COMMERCIAL & INDUSTRIAL BEAM PENETRATION - FLASHING CI-CF-PEN-7 DATE: 12-16-2015