Identification of Hop-Derived Bitter Compounds in Beer
Transcription
Identification of Hop-Derived Bitter Compounds in Beer
Identification of Hop-Derived Bitter Compounds in Beer Using LC-HR-MS/MS André Schreiber SCIEX, Concord, Ontario (Canada) RUO-MKT-11-4016-A For Research Use Only. Not for use in diagnostic procedures. Overview – Hop-Derived Bitter Compounds in Beer • Beer has been attracting consumers over centuries due to its ‒ Refreshing character ‒ Attractive aroma ‒ Typical bitter taste. • Typical beer bitterness is caused by adding cones, • pellets, or extracts of hops during wort boiling. During the wort-boiling process, a number of isomerization processes have been identified to be of major importance for bitter taste development in the final beer. ‒ Xanthohumol → Isoxanthohumol ‒ α-acids → trans- and cis-iso-α-acids ‒ β-acids 2 © 2016 AB Sciex Hop-Derived Bitter Compounds* Xanthohumol H3C Isoxanthohumol CH3 H3C OH HO OH wort-boiling OH O HO O CH3 O OH O trans- and cis-iso-α-acids (such as isocohumulone and isohumulone) CH3 CH3 CH3 CH3 H3C H3C CH3 O OH O OH HO CH3 O H3C CH3 H HO O O H3C CH3 O O H3C α-acids (such as cohumulone and humulone) OH O O H3C CH3 CH3 CH3 H O O HO CH3 OH H3C HO OH H3C H3C H3C H3C β-acids (such as colupulone) H3C CH3 CH3 CH3 CH3 O O H3C O CH3 H CH3 OH O HO H3C CH3 O OH HO OH CH3 HO O H3C H3C H3C CH3 CH3 CH3 3 CH3 H3C * D. Intelmann, G. Haseleu, and Th. Hofmann: J. Agric. Food Chem. 57 (2009) 1172-1182 © 2016 AB Sciex CH3 H CH3 O CH3 O H3C Experimental • Store-bought beer samples ‒ Degassed and diluted 2x with water • ExionLC™ AD system ‒ ‒ ‒ ‒ Phenomenex Luna Omega 1.6 µm Polar C18 (50 x 2.1 mm) Gradient of water/methanol + 5 mM ammonium formate Flow 0.5 mL/min Injection of 5 µL • SCIEX X500R QTOF system ‒ Turbo V™ source with ESI probe, TEM = 450ºC ‒ Mass calibration using the integrated calibrant delivery system (CDS) with the TwinSprayer probe (dual ESI needle). ‒ Information dependent acquisition (IDA) in negative polarity ‒ TOF-MS 100-1000 Da (200 msec) DP = 80 V ‒ 10x MS/MS 50-1000 Da (50 msec) CE = 35 V and CES = 15 V ‒ Dynamic background subtraction on with intensity threshold of 10 cps • SCIEX OS Software for data acquisition and processing 4 © 2016 AB Sciex SCIEX X500R QTOF System powered by SCIEX OS Software SCIEX X500R QTOF system SCIEX ExionLC™ AD system 5 © 2016 AB Sciex SCIEX OS software Profiling of 26 Hop-Derived Bitter Compounds using HR-MS Retention times were established by evaluating data of ~40 beer samples. 6 Identification based on mass error, isotope ratio and RT matching. © 2016 AB Sciex Xanthohumol (X) and Isoxanthohumol (IX) and X/IX Ratio IX IX IX X X/IX = 0.021 X 0.169 X 0.247 German pilsner 7 © 2016 AB Sciex German Weissbier Dry-hoped IPA Xanthohumol and Isoxanthohumol in Different Beers X/IX Ratio Depends on Boiling Conditions and Time of Hop Addition India Pale Ale and Pale Ale 4.00E+06 Stout 3.50E+06 3.00E+06 2.50E+06 2.00E+06 German and Czech Pilsner American Lager Isoxanthohumol Xanthohumol 1.50E+06 X/IX ratio 1.00E+06 Weissbier 5.00E+05 Sgu WHP SCo Pwe Pwa PUQ Pra PSt PKr Pje Pko PHP Pbi PCz Pbe LPA IRU LAS Ioc IMT Iim IMD IHV IHR IHSt IGI IHB IDE Ibo ID9 IbL I10 Bta Bur Aco BBm Abu ACL Ablu ABL 0.00E+00 1.00E+00 9.00E-01 8.00E-01 7.00E-01 6.00E-01 Isoxanthohumol 5.00E-01 Xanthohumol 4.00E-01 X/IX ratio 3.00E-01 2.00E-01 1.00E-01 8 WHP Sgu SCo Pwe Pwa PUQ PSt Pra PKr Pje Pko PHP PCz Pbi Pbe LPA IRU LAS Ioc IMT IMD Iim IHV IHR IHSt IHB IGI IDE ID9 Ibo IbL I10 Bta Bur Aco © 2016 AB Sciex BBm ACL Abu Ablu ABL 0.00E+00 Peak Areas of trans- and cis-iso-α-Acids and α-Acids Czech pilsner (trans/cis = 0.06 and iso-α/α = 121) cis-iso humulone cis-iso cohumulone trans-iso cohumulone trans-iso humulone 9 © 2016 AB Sciex cohumulone trans/cis = 0.02 to 0.15 (American Lager < Pilsner ~ IPA) iso-α/α = 20 to >200 (IPA < American Lager ~ Pilsner) Highest iso-α/α in Irish stout humulone Structural Evaluation using HR-MS/MS in SCIEX OS TOF-MS/MS ChemSpider search and in-silico fragmentation of Isoxanthohumol 10 © 2016 AB Sciex Add HR-MS/MS Spectrum to Library in SCIEX OS TOF-MS/MS HR-MS/MS spectra can be added to mass spectral libraries in SCIEX OS software. 11 © 2016 AB Sciex Increasing Confidence in Identification using HR-MS/MS XIC TOF-MS MS/MS Spectra acquired in TOF-MS-IDA-MS/MS mode are automatically searched against the MS/MS library and flagged by evaluating the library FIT. 12 © 2016 AB Sciex Summary • Profiling of hop-derived bitter compounds in beer using LC-HRMS/MS • Use SCIEX X500R QTOF system with SCIEX OS software ‒ High resolution TOF-MS and MS/MS data acquired in IDA mode ‒ Target peak finding based on molecular formula (suspect screening) ‒ Automatic identification using mass accuracy and isotope pattern, retention times of isomers were assign by comparing results of beer samples with literature value ‒ After structural elucidation HR-MS/MS spectra were added to a spectral library for future work • 40 beer samples were analyzed ‒ Xanthohumol / Isoxanthohumol ratio was compared to conditions of beer making for different styles of beer (i.e. pilsner vs. IPA) ‒ Trans / cis ratio and iso-α / α ratio was evaluated for different beers 13 © 2016 AB Sciex Trademarks/Licensing AB Sciex is doing business as SCIEX. For Research Use Only. Not for use in diagnostic procedures. © 2016 AB Sciex. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX™ is being used under license. 14 © 2016 AB Sciex Thank you for your attention! 15 © 2016 AB Sciex