Sustav nadzora inteligentnih soba - ADRIA
Transcription
Sustav nadzora inteligentnih soba - ADRIA
www.adria-electronic.hr SMART ROOM SYSTEM by ADRIA electronic www.adria-electronic.hr [email protected] ADRIA electronic, Gimnazijske stube 3, 51000 Rijeka, CROATIA Tel.: +385 51 423 435; +385 51 400 838; Fax: +385 51 216 320 (contact person: Vladimir Budislavić, +385 98 215 127) On-line surveillance system overlook (integration and centralization of hotel control) Efficient energy saving through better energy-generating product control Surveillance and control of illumination, climatization, bathroom heating, water-flow, telephone, window blinds and other feeders along with optimization of their way of work may result in significant amount of energy saving, relating to size, position and type of object. Better and more efficient staff and quality-of-service survey Log lists, controllers for monitoring to-do lists, staff traffic reports, system for quick distribution of messages, staff locator module: they all provide more efficient staff organization. Better, simplier and more secure monitoring system for room access Transponder cards combined with on-line system makes room access more secure and more efficient. Any room controller can be reached simply from reception desk including programming and deleting of card codes enabled for the present room. Staff cards can access to all controllers (rooms) and in case of losing they can easily be replaced in all hotel. On-line system makes almost momentary annuncing of card registration along with automatic invalid cards cancellation. Alarms – SOS, BURGLAR, TEMPERATURE, WATER, SUPPLY... (improved security and quality of service) Thanks to on-line system, alarms can be transfered to reception desk almost instantly and also distributed to liable persons. Generating reports (printer, e-mail, web - report) On-line system records all important informations in log files. From this files reports can be generated such as: movement of explicit person, staff’s undone duties, events in room (room temperature, alarms, entry/exit), possible un-checked guests, etc. Smart Room Each room is equipped with a single microprocessor-driven room controller Sensors or actuators for all devices/measurements/condition monitoring can be placed to any suitable place to survey and/or control A card reader is installed in front of the door, and a card holder is mounted in the lobby (smart card holder able to recognize valid card) A control console and lighting control keyboard is also installed in the room The room controller (autonomous device for controlling resources and devices in the room) Very simple assembly and disassembly that makes the replacement easy and quick even without authorised dealer (connections are made via connectors) Construction is made to fit in standard dash board on DIN rail (9 module width) Controller is modular by it’s functionalities according to consumer’s request Separate power supply enabled over electrical generating unit, UPS or battery Power supply.......................230V -15% +10%, 50Hz Max. consumption............…20VA Communication ...................RS485 opto-isolated Sensors and actuators Following description is made for a standard set of sensors provided with the room controller. Modular conception allows use of other types of sensors/actuators according to consumer’s request. INPUTS OPEN-WINDOW sensor (window closed = closed contact) OPEN-DOOR sensor (door closed = closed contact) SOS-alarm (bathroom) sensor WATER-OVERFLOW (bathroom) sensor TEMPERATURE-PROBE inputs (room and bathroom) WINDOW BLINDS-CONTROL inputs (rise/lower) WELLCOME LIGHT-CONTROL and control of other lighting inputs SPARE INPUTS (enabled for smoke detector, PIR-detector, etc.) Sensors and actuators OUTPUTS • • • • • • • • • • ELECTRIC STRIKE-CONTROL - 12 VDC output, LIGHTING CONTACTOR-CONTROL – 230 VAC output, 3-SPEED FAN-COIL-CONTROL – 230 VAC output, VRV/VRF AIR CONDITION UNIT CONTROL – non-voltage contact output, LIGHTING CIRCUITS CONTROL – 230 VAC output, 2-VALVE-CONTROL (FAN-COIL valves) – 230 VAC or 24 VAC output (with additional 230/24 VAC transformer), WELLCOME LIGHT-CONTROL – 230 VAC output, WINDOW BLINDS-CONTROL (rise/lower, used also for shades) – 230 VAC output, VARIOUS ELECTRIC HEATERS CONTROL (floor, wall heating) – 230 VAC or 12 VDC output with “noiseless” contactor, HOT AND COLD WATER-VALVES COUNTROL– 230 VAC or 24 VAC (with additional 230/24 VAC transformer) Transponder Card reader Mounting: Vimar Idea/Plana/Eikon, Gewiss Playbus/Chorus, AVE Sistema45, Merlin Gerin Unica, Master MODO, BTicino Living and Light 3-module installation box, Power-supply: through room controller over flat telephone cable 8x0,14 mmq, Reads card code at cca 5 cm distance and sends it to room controller for identification, Signalization: guest in the room, do-not-disturb, room-maid attention, SOS. Transponder Card holder Mounting: Vimar Idea/Plana/Eikon, Gewiss Playbus/Chorus, AVE Sistema45, Merlin Gerin Unica, Master MODO, BTicino Living and Light 3-module installation box, Power-supply: through room controller over flat telephone cable 6x0,14 mmq; recognizes card identity, Reads put-in card code and sends it to room controller for identification (valid card makes controller enable room power supply and switch air-condition to COMFORT mode). Room operator unit Mounting: Vimar Idea/Plana/Eikon, Gewiss Playbus/Chorus, AVE Sistema45, Merlin Gerin Unica, Master MODO, BTicino Living and Light 3-module installation box (4-module with temperature probe on-box), Power supply: through room controller over flat telephone cable 8x0,14 mmq, Enables air-condition control and signaling (do-not-disturb, roommaid attention, messages on display, buzzer). Lighting control keypad Mounting: Vimar Idea/Plana/Eikon, Gewiss Playbus/Chorus, AVE Sistema45, Merlin Gerin Unica, Master MODO, BTicino Living and Light 3-module installation box (4-module with temperature probe on-box), 4 keypads can be attached to room controller, Control of lighting in the room, 6 key for 6 different light circuits + MASTER ON/OFF key – by pressing the MASTER ON/OFF key one can turn off all lights in the room, by pressing it again last switched on lights are turned on, Power supply: through room controller over flat telephone cable 8x0,14 mmq; more keypads are connected in cascade (series). Electric strike (on door-post) (in combination with hotel lock) Way of work Keylock bolt is permanentrly involved (doorlock is opened). When door is shut, door-knob bolt is blocked if electric strike in position A, or free if electric strike in position B. When controller recognizes valid card code, its output enables electric strike in position B for few seconds (door is open). ELECTRIC STRIKE (with flat plate) HOTEL LOCK (with self locking mechanism) Hotel lock with self locking mechanism is mounted on door with a pull on the outside (instead of classic door-handle). In it’s last turn the lock has to open the door-lock bolt. Instead of classic lock, electric strike connected to room controller is mounted on door-post – used in combination with hotel lock. Door knob bolt Keylock bolt ROOM Electric strike HALL Controller connections (layer I) (room controller – card reader – card holder – electric strike) 1. A valid card is put in front of card reader 2. Card reader transfers card code to controller 3. Upon valid card code, controller activates electric strike: door is opened and welcome light is lit 4. Guest inserts the valid card into card holder 5. Card holder transfers card code to controller 6. Upon valid card code, controller enables room power supply, switches air-condition to COMFORT mode, enables local window blinds control. When the card is removed, after 30 sec controller disables room power, switches air-condition to ECONO mode, disables local window blinds control (controlled over PC) Controller connections (layer II) (room controller – open door sensor – open window sensor – control console – air-condition) 1. Window sensor registers opening of 2. Controller receives information that the window. window has been Window opens... opened. 3. Upon opened window, controller turns off 3-speed, 2valve air-condition. ! If the window (door) is open, controller turns off air-condition. ! Upon air-condition failure (no power supply or other), controller sets alarm. ! If window is open without the card in card holder, controller sets alarm 4. Open door sensor registers opening of the door. Door opens... 5. Controller receives information that the door has been opened. ! If the door is open without the card, controller sets alarm 6. Control console is used to set up controller parameters. One can regulate room temperature within allowed limits, mark “room-maid attention”, mark “do-not-disturb”. Controller also provides messages such as “door opened”, “window opened”, “call reception”, “doorbell”. Controller connections (layer III) (room controller – alarms, warnings) SOS - a stroke (pull) switch is mounted in bathroom enabling user to pull when in immediate need; - controller registers active transition of SOS contact and sets alarm; - upon set alarm, a blinking lamp appears on card reader along with message “SOS” on controller console’s display; - alarm also appears on reception’s PC SW; - alarm can be confirmed 3 ways: by PIN (PC SW), by official master card put in card holder, by pressing hidden key on controller console. Water overflow (bathroom) - a water presence sensor is mounted above the floor in bathroom; - when water present, controller sets alarm visible only on reception’s PC SW; - if a controlled valve is used, controller automatically closes it, thus stopping water income. - alarm can be confirmed by PIN (PC SW) Unauthorised access - if the door are opened without the card, controller sets alarm visible only on reception’s PC SW; - alarm can be confirmed by PIN (PC SW) Controller connections (layer III) (room controller – alarms, warnings) Air-condition power failure - controller monitors (separate) air-condition power supply ; - controller registers no air-condition power supply failure (due to broken fuse or faulty air-condition) and sets alarm visible only on reception’s PC SW; - alarm can be confirmed by PIN (PC SW). PIR detector - mounted inside the room; - when there’s no card in card holder if movement is detected, PIR detector “goes off”; - controller registers PIR detector’s active state and sets alarm visible only on reception’s PC SW; - alarm can be confirmed by PIN (PC SW). Room-maid attention / do-not-disturb - activated using control console in the room; - when set, a lamp is indicated on control console, along with a lamp on card reader; - warning also appears on reception’s PC SW; - warning can be confirmed by PIN (PC SW). Controller connections (layer III) (PC SW – alarms, warnings) High temperature difference - PC SW monitors difference between set and measured temperature in room; - when the difference is higher than allowed (user defined, difference due to air-condition failure) an alarm is automatically set; - alarm can be confirmed by PIN (PC SW). Call reception - set from reception’s PC SW when needed guest’s attention at reception; - if set, when a guest card is placed into card holder (in the room), a message “Call reception” appears onto control console along with a beeping sound that indicates the guest to check at the reception; - active warning also appears on reception’s PC SW; - warning can be cancelled by PIN (PC SW). On-line network – system monitoring Basic elements inside room Room controller Card reader Card holder Control console Electric strike Open door sensor Open window sensor SOS sensor Standard dashboard Temperature probe Fan-Coil Water overflow sensor EM water valve Window blinds PIR sensor Backup module (option) PC SW Room 201 Room 101 Room 202 Room 102 Room 203 Room 103 All room controllers are connected in RS485 bus via a twisted-pair wire Cyclic polling of each room controller (cca 50ms/cont.) Room controllers are autonomous, regardless PC state/failure (keeping parameters and programmed cards) Controlling the room temperature Temperature control is based considering following parameters: • Temperature set – represents default desired room temperature, • Room temperature regulation – boundaries around temperature set within one can change desired room temperature • Eco. Hysteresis – temperature set’s bias usedwhen guest isn’t in the room • Additional temperature hysteresis - when the room isn’t checked within next 24 hours • Temperature calibration - possibility of fine tuning measured temperature Parameters are set by an authorised person using PC SW. One can set the room temperature only within allowed boundaries. Energy saving regulation example - Temperature set: 21°C - Room temperature regulation: ±3°C - Eco. hysteresis: ±3°C - Additional temperature hysteresis: ±6°C When guest is in the room (valid card in card holder), allowed regulation is 18÷24°C. When guest leaves the room (but, the room is still checked), controller automatically sets room temperature at 18 or 24°C, depending on air-condition heating/cooling state. When guest returns in the room (valid card returned in card holder), controller enables room temperature regulation. If the monitoring system is connected to supported hotel management, a reservation list based guest announciation module is enabled. Monitoring system increases energy saving by enabling additional eco. mode for rooms that aren’t going to be checked within next 24h. Cards – classic key replacement Dimension: L85mm, W54mm (ISO standard card) Type: contactless card (transponder) Resistant to pressure and scratching, impassive on magnetic fields Available in various forms: keychain, bracelet... Printable plastic surface, ready-to-print logos Undefinite use (until phisically damaged) Principle Card contains an integrated circuit and an aerial. When it is held near an electromagnetic field with corresponding frequency, the field provides power supply by induction to integrated circuit thus enabling it to generate and send a uniform 40-bit card code that needs to be read using complex integrity check algorithms. With 40-bits there can be 240, or 1.099.511.627.776 different cards, all this up to providing extreme exploitation security. After reading, system sends the code to controller and if it’s the valid one, the door is opened. Inserting valid card in card holder controller enables “Guest in the room” mode. When the validity of a certain card expires or it’s manually deleted from the system, controller receives the information that this certain card is no longer authorized for this controller/room (the card itself isn’t deleted, it can be used for other rooms or purposes). Recommandations in use It is recommended not to fix cards with room numbers and not to print room numbers on cards. System of protection is best when issued cards are selected randomly. Access control and hotel service payment (additional card usage options) Controllers can be used in any place inside or outside the hotel where there is necessity for access control (garage, parking ramp, pool entry, sauna, solarium, etc.) When issuing the card one can choose where it can be used. In this way, for example, garage access can be granted only for guests that paid this service. Access controlling controller can be time programmed in several modes: 1. fully accessible within a certain period of time (card not needed) 2. fully accessible to all hotel cards within a certain period of time 3. dual access capability (card and/or key usage) 4. not accessible within a certain period of time If monitoring system is connected to hotel management system, key-cards can be used as identification during payment at any place equipped with POS cash-desk. One card for all! Guest cards can... access one room, room vault(option) access additional facilities with permission pay bills on POS cash-desks Staff cards can... access all rooms (or certain room groups) access additional facilities with permission disable alarms with permission Hotel entry garage, parking lot Wellness, pool, sauna, wardrobes... Room, room vault POS cash-desk at any place inside or outside hotel (beach bar..) Other functions and devices 1 Backup module (option) – takes over room monitoring in case of PC failure in a way that recepcionist can register alarms and change the air-condition mode. Recommended for larger hotels. Staff registration module (option) – staff member has to register himself/herself after the job is done. Device records time and person’s name (written on display) and can be set to alarm reception if the required registration isn’t done in time. Basic purpose is to replace toilette cleaning schedule (any time PC SW can print a report). Card “programmer” (basic package) – connected to reception’s room monitoring PC or front-office reception management PC (if the connecton to room monitoring PC is available). When new card is to be issued, one has to put the (non-issued) card onto card programmer and execute “programming”. If the card is used for payment, card programmer is connected to POS cash-desk. Other functions and devices 2 Quality and consumption of electrical energy supervision module, consumption of hot and cold water supervision module (if pulseoutput water-gauges are used) – electrical energy survey. Module displays current values of voltage, current, power (real, reactive, apparent), voltage and current harmonics, THDs and consumpted energy (real, reactive, positive and negative) by tariffs. Programmable control module (option) – along with standard input/output and measuring functions (analogue and digital inputs, aka pool water and ambient temperature, wind strength, etc.) this module can be equipped with different electrically controlled devices such as fountains, lighting, shades, watering systems, etc. According to defined program (defined on PC SW) module automatically controls attached devices. The equipment is fully compatible to DALI, 0-10V and other light control systems. Software package for central control and monitor over system Software package in real-time makes possible... setting room controllers’ parameters data visualization representing current hotel state audible and visual alarm representation (with obligatory confirmation) key-card registration and deletion controlling various devices inside and outside hotel monitoring various resources (water, current cosumption,...) log-files overview containing all relevant events generating reports based on log-files connecting to reception managment system check-in/check-out authorised personnel staff sms, e-mail, pager redistribution of messages recording and reviewing room data client-server mode of work Levels of access in software Three levels of access: Unsecure level PIN provided access PUK provided access PUK is a number defined by ADRIA-electronic and can be used only by authorised personnel in aim to change settings or maintenance of PC SW. Each program installation has different PUK. PIN is a number used for personnel identification. Various actions in program require identification in order to record a name of person who carried out certain action (i.e. confirming of alarm). PINs are defined by authorised personnel. Authorised recepcionist – software makes possible authorised receptionist’s check-in/checkout responsible in specific time period. Durig report generation, events recorded in log-file are linked to the person who directly carried out recorded action ant to authorised receptionist. Data protection – all card and log-file data are crypted according to a certain key. Software’s main screen Option control menu (pull down menu with toolbar) Select status to display All rooms status display Main logfile: notification s, alarms, warnings Legend describing displayed status System line Room status display (current status and values) Graphic list enabling select of status to be monitored Room number. Background color indicates status: guest in the room, sos (guest in the room), sos (guest not in the room), unauthorized access. Graphic representation of monitored status Room floor Room status display shows every room Hotel (object) is displayed schematically according to room, floor, dilatation, (...) arrangement and is adjusted individually for each installation Room status display can show each status from controller This window represents current on-line hotel overview Chosen status visible in “a glance” Room status symbols and selection By left-clicking the mouse on a status on tool bar, one can choose which status to monitor (for all rooms) Red background color indicates alarm for that status Lowest row in graphic list contains buttons for direct control on some devices (window-blinds, ...) Status >> Status symbols shown in room status display << Door status Door open Door closed Window status Window open Window closed Clean status Room cleaned Room-maid present “Do-not-disturb” Do-not-disturb Wellcome light Wellcome light on Air-condition stauts x – cooling speed x – heating speed 0 – fan stop ‘-’ – air-condition off x. – window open Status Control console keypad >> Status symbols shown in room status display << Keypad locked Service Managment Personnel watch Room-maid Temperature set Set room temperature displayed Measured temp. Measured temperature displayed High temp. Diff. Measured temp. too high Call Reception Call reception Enabled Room-maid Attention Room-maid att. enabled Water overflow Unconfirmed Confirmed Receptionist Status >> Status symbols shown in room status display << Air-condition power failure Unconfirmed Confirmed Key-card validity Soon to be expired No key-cards reg. for this room Graphical representation of a room Double-clicking left mouse key on room number or status a graphical representation of a room pops up: Alarms presented graphically: SOS Water overflow Unauthorised access (burglar) Informations presented graphically: Door open / closed Window open / closed Air-condition on / off + fan-coil speed Wellcome light on / off Signal “do-not-disturb” on / off Presence presented graphically: Picture is real-time refreshed. It can be seen presence of guest, window is open and air-condition is off, SOS is set and water overflow is present. Lower right corner shows temperatures. Guest Room -maid Manag. Service Recep. Thief Room detailed data Double clicking left mouse key onto graphical representation of a room a detailed data window pops up Programming and reading of temperature parameters Temperatures readout, used cards survey and log-file browsing for chosen room Legend Disabling control console’s keypad, Disabling open window sensor, override card holder (in case out of order until repaired) Service info – controller input/output state Air-condition settings Modes: manual, automatic, A/C module Manual mode enables manual setting of air-condition mode: heat or cool Automatic mode: one controller is enabled as referent – according to it’s parameter state and logic air-condition mode is set A/C module is mode where system autonomously control air-condition (particular cotroller needs to be installed according to air-condition engineer) Room groups To make air-condition parameters set simpler, room groups are implemented. In this way groups like “rooms-nord”, “rooms-south”, “rooms-1st floor”,(...) can be made and separate set of parameters can be given. Groups are formed by authorised person (PUK needed), and setting of parameters is controlled by PIN. Groups are formed in the way a group name is set and a room list is formed. During programing of parameters software shall offer all defined groups. By selecting “Send” option, software sends new parameters to all rooms in the group. All rooms can be preprogrammed by a single step! Cards: categories and validity time Four card categories: Guest cards Visitor cards (persons using hotel facilities but not rooms) One-time cards (deleted after first use) Personnel cards dividen onto: room-maid, service, management, reception.... Validity time Validity time has to be set for each card. After validity time expiry system automatically deletes the card and card is unusable (in this way card abuse is prevented after checkout, or possible fake card loss). Cards are phisically identical, categorisation is based on software level All data connected to card (code, category, user) are password protected There can be 3 guest cards per room and 2 general purpose cards (guest, service...) Working with cards – basic steps Registration (issuing) of a card – card code is read and sent to controller; code, owner and access control sector entry is formed in database Changing of data – all changes including room change, prolongation of accomodation don’t need presence of a card. The system works automatically with code from database. In this way, a guest can be transferred from one room to another in few simple steps, or his/hers accomodation can be prolonged without necessity of his presence. Deleting of a card – is accomplished in a single step without a presence of a card. Software sends to all controllers the information that a certain card is no longer valid. Deletion can be done manually, automatically (due to validity time expiry) or directed from reception managment system. Key-card options (definition of access control controlers (main entry, garage...) Whilst card issue receptionist shall be offered a list named “Key-card options” in which access control sectors can be enabled/disabled for the current card. List is created by authorised personnel, and receptionist can setup default state offered during card issue process. In given example a list of access control controlers is defined. When issuing a new card the software is going to enable access entry into garage and main entrance by default. Method of card reading When software sends card registration request, card programmer display shows adequate room number and it’s last digit shows dashes representing position of a issued card. When issuing personell cards, card programmer display shows only blinking dashes: - - - - Receptionist has to lay the card onto card programmer, wait until programmer beeps and remove the card. If reading/issuing is successful display will show still dashes: - - - If there is an error while reading, display will show: err Description of an error is always written in a log-file. Method for personnel card registration Access to personnel card list is protected by PUK. Given table shows all relevant data for issued personnel cards. Currently selected position (possible to edit) is marked with red arrow in first column. With mouse right-click a menu is opened that allowes deletion/ changing of data for currently selected card or issuing a new card if the field is empty. Registration of a card in three steps! 1. 2. 3. Choose position Enter data Press “Confirm” button Selecting the position from card list and make/change data of a card menu, a window pops up enabling to edit card associated data. Along with registration of a card it is possible to enter/edit PIN. Card is registered/deleted by clicking the “Confirm” button Method of issue is similar for registration of a visitor’s card (PIN isn’t defined) Method for guest card registration Issuing and deleting of cards is simple. It can be done after only 10 minutes of training! Issuing • • • Right mouse click on desired room Enter data and choose access control sectors Press “Confirm” button Deleting • • Right mouse click on desired room Press “Cancel(Delete)” button If monitoring system is connected to reception management system (PMS) card issuing is done automaticaly (commands are sent by PMS over LAN) Identification of a card Due to safety cards shouldn’t have any special markings that could associate with a person or a room. Nevertheless, if we still wish to enable overview of data (in case of card found) a card identification module is implemented. Card is layed on the card programmer (reader) and a “Read card” button is pressed. As a result, all card data is shown. If the card isn’t found in database, software automatically informs all controllers that present card is no longer valid. Alarms, warnings, informations System is designed so that each and every type of alarm it must know who is authorised to accept, confirm and react on alarm activation. Appereance of alarm Log-file record entry upon which reports are based Log-file record entry YES Confirm on time NO Message redistribution over sms, pager or email to superior person Visual notification on main screen (graphically and textually) NO Alarm 1. categ. ? YES Audible information (over loudspeaker in reception PC or other according to client’s choice) Types of alarms and warnings Alarm / Warning Description Sound Symbol SOS, guest in the Guest pulled SOS chord in the bathroom room YES SOS, guest isn’t in the room SOS has been pulled but there’s noone in the room. YES Water overflow Water in bathroom has reached the water sensor level. YES No communication Room doesn’t communicate. Comunnication break. YES Unauthorized access The door is opened without card YES Alarm / Warning Description Sound Symbol Guest in the room When guest’s card is in the card holder... NO Room-maid attention Guest can enable this warning on control console. Over reception PC warning can be redistributed directly to authorised person by sms, pager or other. YES “Call reception” Sent notification to guest’s room. NO High temperature difference Measured temperature too high NO Air-condition power failure Air-condition power supply isn’t present or aircondition failure NO Expiry of cards Surveillance over expiry of cards can be enabled. Expiry is alarmed. NO Acknowledge of alarm Each alarm must be acknowledged by PIN. Right mouse click on the room allarm was assigned to. Instead of registration card window, a alarm confirmation window is opened. In given list all actual alarms are shown. Confirmation applies to all allarms on the list. Alarm can be confirmed in 2 ways: enter PIN and press OK place a PIN registered card onto card programmer and press OK Message redistribution Messages and reports can be automatically redistribuited as: • sms messages • pager • e-mail • web reports Redistribution levels: • System sends message directly to choosen person For example, “call roommaker” can be directly sent to roommaker who responsible for room from where the signal is sent. • Conditional message For example, if some alarm is not acknowledget for some time, it can be redistribuited to some superior person. • Program can work in client mode, so it is possible to make passive monitoring from any LAN point. @ Connection to PMS system PMS Back office PMS Front office 1 Smart room’s monitoring system LAN Communication is based on standard LAN network PMS Front office 2 POS Keycard readers are directly connected to PMS devices (front office, POS) We have succesfull cooperation with next PMS systems: MISH (Istra Informatički Inženjering Pula) / www.iii.hr Opera-Fidelio (Micros Zagreb) / www.micros-fidelio.hr iSustav (Milenij Čakovec) / www.milenij.hr HREC*KOR (KOR Zagreb) / www.kor.hr Sihot (Gubse) / www.gubse.com •Protel (Protel hotelswoftware) / www.hotinf.hr Hotelski informacijski sustav (ITI computers Dubrovnik) / www.iticomputers.hr GP Dati / www.gpdati.com WE ARE READY TO BUILD CONNECTION TO ANY OTHER PMS SYSTEM! Connection of smart room system to PMS makes possible: • Faster and easier guest check-in. Receptionist enter data in front office, and monitoring system receives commands for check in, chieck out and data change directly from front office. • Energy management. PMS sends information about rooms reservation scheme, so monitoring system can handle additional level of energy savings. • Phones control. Monitoring system sends to PMS information when guest is in the room, so PMS can switch on phone line, and if guest is not in the room phone line can be used only for internal connections (inside hotel, hotel’s staff can not make phone calls from rooms). • Prepare keycards in advance. It is possible to prepare keycards in advance (if large group of guests is expected). • Makes possible to identify guest by keycard. POS points are equiped with special readers and guest can handle payment just with his keycard. Main LOG file Main LOG file (always presented on screen), contains: Alarms (appearance, disappearance, acknowledge) Details about link to PMS system Communication information Climatisation settings Receptionists check-in,check-out System data (start and end of program, comm system data...) Information about control programs of external devices LOG file is protected Main LOG file is used to inform receptionists all important information about system! Log ID LOG time LOG description Room’s LOG files Room’s LOG file contains information about: • Keycard creation i canceling • Room’s door (enter, exit) • Automatical canceling of keycards • LOG is circular (300 items) • LOG file is protected Fast info window Info window can be used for fast reminder (for example some short notes about system). Direct resources monitoring It is possible to include in program special module for monitoring of energy resources and processes (for example monitoring of el. power system, water consumption etc.) At every moment is possible to know consumption of any monitored resource in hotel! All signal’s data are recorded and can be analysed later. Special program makes possible to create graphical presentation of data. Controlling of elect. devices Any equipment can be connected to control station by proper interface For each connected equpment is possible to setup on-off times Program recognize workday,weekend, hollidays, day and night Each connected equipment can be controlled and manually from PC Lights for hotel’s public places grass watering Internal and external decorative lights Fountains, Waterworks Lights for grass, stairs, passages, parkings Support for clients Back up – daily automatic backup of the most important files (codes of keys, program settings etc.). In case of hard disc accident, program can be restaurated on other computer in few minutes and recepcionist can cotinue from break point! Remote service – program service or support for recepcionists can be performed by PC remote control over phone line or internet connection. Service in short time period – in case of serious defect, our servicer will handle it in agreed time period. Spare equipment – every hotel is equipped with spare equipment (main room station and other peripherials), so hotel’s repairman can easily and fast change broken parts. Phone and e-mail support – our support staff will be in disposition by phone or e-mail for any recepcionist’s question and help them to handle any problematic situation. Whole this system is completely developed and produced in our company and that is assurance that any question and help concerning usage and maintence will be answered in shortest possible time! ADRIA-electronic company – short preview Founded 1974. 15 employees Basic activities are industrial electronics and automatics, developing and production of microprocessor based devices for controling, monitoring and measurement, and development of software (for example controlling and monitoring of petrochemical plant Polikem in Zadar, monitoring of electro-energetic system of petrochemical plant Dina in Omišalj, many controlling and monitoring systems in Croatian national oil company INA and Croatian public elect. supply company HEP, monitoring of intelligent rooms and offices, developing and production of measurement instruments and analysis software for few EU companies). We are using SMT tehnology and all our products are built on our SMT production line. Reference 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Hotel Dubrovnik, Zagreb, 260 rooms, elevator Hotel Kolovare, Zadar, 250 rooms Hotel Excelsior (LRH), Lovran, 187 rooms Hotel Kristal (LRH), Opatija, 131 rooms TN Amarin (Maistra), Rovinj, 271 app. TN Petalon (Maistra), Vrsar, 224 app. TN Blesička (Maistra), Vrsar, 119 app TN Belvedere (Maistra), Vrsar, 330 app Hotel Istra (Maistra), Rovinj, Crveni otok, 326 rooms, 14 app Hotel Istra Garden (Istraturist), Umag, 281 rooms, 12 app, 16 entrance controls Hotel Bellevue (ALH), Dubrovnik, 93 sobe sa upravljanjem tendama, 1 elevator Hotel Ivka, Dubrovnik, 72 sobe, 2 entrance controls Hotel Marko Polo, Korčula, 103 rooms, 2 app Casino Mulino, Plovanija, 62 rooms, 16 entrance controls, 2 elevators TN Zaton, Zaton, 136 app Hotel Delfin, Omišalj, 48 rooms Hotel Marina, Selce, 64 rooms, 10 entrance controls Hotel Terme Jezerčica, Donja Stubica, 51 rooms Hotel Park, Lovran, 50 rooms Vila Astra, Lovran, 8 rooms 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. Vila Eugenija, Lovran, 16 rooms, 5 entrance controls Hotel Plaža, Pag, 35 rooms, 7 entrance controls Hotel Korana Srakovčić, Karlovac, 21 rooms, 1 entrance controls Hotel Vali, Dramalj, 22 rooms, 3 entrance controls Robni terminal Kukuljanovo, 50 offices, 7 entrance controls Hotel Savoy, Opatija, 35 rooms, 1 entrance control Hotel Tamaris, Novi Vinodolski, 15 rooms, 1 entrance controls Villa Annette, Rabac, 12 app., 4 entrance controls Hotel Manora, Nerezine, 23 rooms, 3 entrance controls Hotel Miramare, Njivice, 26 rooms Vile Irena i Hilda, Dramalj, 24 rooms Hotel Indian, Orebić, 22 rooms Hotel Studenac, Omiš, 15 rooms Hotel Savus, Sl. Brod, 15 rooms Hotel Meridian, Pag, 51 rooms Hotel Picok, Đurđevac, 80 rooms Hotel Arbiana, Rab, 28 rooms Hotel Laguna, Privlaka, 23 rooms Vila Kaštel, Povljana, 13 rooms Hotel Radon Plaza, Sarajevo (BIH), 116 rooms Hotel Maestral (Laguna Novigrad), Novigrad, 320 rooms 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. Hotel Luna, Jakišnica (o.Pag), 96 rooms Hotel Laguna, Zagreb, 150 rooms Hotel Adoral, Rabac, 15 rooms, 1 entrance control Hotel Atrium (Splendia luxury&character hotels), Split, 102 rooms Hotel Excelsior (ALH), Dubrovnik – Vila Odak, 65 rooms, 65 safes, 1 entrance control – glavni toranj, 95 rooms, 95 safes, 47 HVAC controls – Villa Agava, 8 rooms, 2 safes, 3 entrance controls Hotel Admiral, Slano, 218 rooms, 27 app, 1 entrance control Grand hotel Orebić ex Rathaneum, Orebić, 204 rooms, 1 app TN Stella Maris (Istraturist), Umag, 180 app Aquareumal Apartmani, 76 rooms, Fojnica (BIH) Hotel Holiday Inn, Beograd (Srbija), 140 rooms Hotel Lucić, Sl. Brod, 17 rooms Odmaralište INE, Malinska, 26 rooms Villa Ambasador (LRH), Opatija, 40 rooms, 12 app Viletta Phasiana, Fažana, 18 rooms, 1 entrance control Igralnica in hotel Safir, Sežana (Slovenija), 51 rooms Hotel Zenica, Zenica (BIH), 100 rooms A Hotel, Ljubljana (Slovenija), 26 rooms 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. Hotel Aurora (Jadranka hoteli), Mali Lošinj, 400 rooms Hotel Lapad, Dubrovnik, 166 rooms Hotel Kimen (Cresanka), Cres, 134 rooms Hotel Prelog, Prelog, 12 rooms Hotel Marina (LRH), Mošćenička draga, 183 sobe Pansion Begić, Makarska, 18 rooms Istarske toplice, Livade, 26 rooms Hotel Monte Mulini (Maistra), Rovinj, 140 rooms Hotel Marina, Krk, 10 rooms Hotel Koralj (Istraturist), Umag, 250 rooms Hotel Casa Grande, Međugorje, BIH, 16 rooms Hotel Sarajevo, Sarajevo, BIH, 39 rooms Langedijk, Nizozemska, 15 rooms + 6 access controls Hotel Dubrovnik, Zenica (BIH), 36 rooms, 6 halls Hotel Vitez, Vitez (BIH), 30 rooms Hotel Pakrac, Pakrac, 10 rooms Hotel Lika, Gospić, 30 rooms, 15 access controls, under construction Terminal Metis, Kukuljanovo, 35 offices, 9 PLCs for light control Hostel Feri, Igman (BIH), 39 rooms Hotel Turist, Varaždin, 46 rooms, 1 entrance control Hotel Townhouse 27, Beograd, 20 rooms Hotel Aristos, Zagreb, 74 rooms Hotel Vespera (Jadranka), Mali Lošinj, 422 rooms, 21 light controls 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. Hotel Valamar Lacroma Resort (Valamar), Dubrovnik, 401 rooms Hotel Palazzo, Poreč, 74 rooms Hotel Villa Lenije, Vinkovci, 22 rooms Hotel Osejava, Makarska, 49 rooms, lights, entrance controls Hotel Imperijal, Vodice (Šibenik), 45 rooms Hotel Villa Dubrovnik i Villa Kolin, 56 rooms Hotel Tuzla, Tuzla (BIH), 55 rooms, 4 app Motel Petrol Desinec, Desinec, 25 rooms Hotel Crystal, Beograd (Srbija), 44 rooms T-HT, Rijeka, 95 offices Vila Magdalena, Krapinske Toplice, 9 rooms Hotel Kaštel, Kastav, 15 rooms Hotel Joso, Sukošan, 15 rooms Hotel Bastion, Zadar, 28 rooms Apartmani Tikvić, Crikvenica, 10 aps Apartmani Štrljić, Selce, 3 app Villa Jurjevska, Zagreb, 30 rooms Hotel Split, Split, 156 rooms, 25 app Hotel Marjan (u izvedbi), Split, 204 rooms, 3 app Hotel Grace, Međugorje, 39 rooms Hotel Lux-e, Split, 27 rooms, 3 app 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. 123. Hotel Mediteran, Poreč, 332 sobe, light contorl, Zaton apartmani, 3 sobe, 7 app Hotel Mauro, Poreč, 21 rooms Villa Astoria, Kotor (MNE), 10 rooms Hotel Bali, Beograd (SRB),16 rooms HZZO-HZMO, Rijeka, 125 offices Hotel In, Međugorje (BIH), 16 rooms, 4 app, light control, access controls Upravna zgrada Rivijera, Poreč, 89 offices Hotel Diamant, Poreč, 210 rooms, 34 app Hotel Adria, Dubrovnik, 73 rooms Hotel Idila, Zlatibor (SRB), 18 rooms, Hotel Sirius, Priština (RKS), 52 rooms, 4 app Hotel Golte, Mozirje (SLO), 54 rooms, 13 access controls Hotel Life Design, Beograd (SRB), 56 rooms, 3 access control Hotel Monika, Trogir, 16 rooms Hotel Jana, Međugorje (BIH), 42 rooms Hotel Marconi, Međugorje (BIH), 27 rooms Hotel In, Međugorje (BIH), 20 rooms Hotel Degenija, Plitvice, 20 rooms, 2 entrance controls Hotel Residence, Zagreb, 17 rooms, 15 entrance controls Hotel Bristol, Sarajevo (BIH), 186 rooms, 16 entrance controls (Shaza Kempinski) 124.RTB Bor, Bor (SRB), 12 rooms 125.TN Zelena Punta, Kukljica Ugljan, 132 app 126.Vila Sv. Jakov (Hotel Milenij), Opatija, 26 rooms 127.Vila Lovorka (Thalassotherapia), Crikvenica, 9 app/rooms 128.Hotel Lone, Rovinj, 265 rooms 129.Hotel Čuljak, Slavoniski Brod, 8 rooms 130.Hotel Centar, Sarajevo (BIH) 131.Hotel Central, Vitez (BIH), 23 rooms 132.Hotel Swiss Diamond, Priština (Kosovo ), 160 rooms 133.Odmaralište Laško, Ičići, 7 app 134.Pansion Dina, Međugorje (BIH ), 40 rooms 135.Vela Nera, Šišan, 13 rooms 136.Vila Carmen, Opatija, 15 app 137.Hotel Monaco, Međugorje (BIH), 40 rooms 138.Hotel Life, Zečevo (Rogoznica), 20 rooms 139.Hotel Čilipi, Čilipi, 15 rooms, under construction 140.Hotel DG Sport, Prelog, 18 rooms, 20 entrance controls 141.Hotel Sport, Ivanić Grad, 23 rooms, 5 entrance controls 142.Hotel Alfanet, Novi Sad (SRB), 30 rooms, under construction 143.Tuheljske toplice, Tuhelj, 225 rooms, 4 entrance controls, under construction 144.Hotel Trakošćan, Trakošćan, 125 rooms 145.Hotel Atrij Superior, Zreče (SLO), 50 rooms (Unior SPA Resort) 146.Hotel Srebrenica, Srebrenica (BIH), under construction 147.Hotel Pašina Česma, Leskovac (SRB), 60 rooms 148.Hotel Park, Ruma (SRB), 73 rooms 149.Hotel Pleter, Mimice, 35 rooms 150.Hotel Calypso, Lučko, 25 rooms 151.Hotel Hilton, Zagreb, 152 rooms 152.Apartmani Novak, Novalja, 10 rooms 153.Hotel Klemo3, Međugorje (BIH), 10 apartments 154.Hostel Forum, Zadar, 37 rooms 155.Hotel Importane Royal Princes, Dubrovnik, 55 rooms 156.Hotel Loop, Ljubljana (SLO), 23 rooms, 157.Hotel Grace2, Međugorje (BIH), 41 rooms 158.Hotel Split Podstrana, Split, 40 rooms 159.Hotel Međugorje, Međugorje (BIH), 96 rooms, 3 apartments 160.Hotel Plaža, Omiš, 154 rooms 161.Hotel Nikić, Podgorica (MNE), 71 rooms, under construction 162.Hotel Oasi, Pula, 9 rooms 163.Hotel Leonardo, Međugorje (BIH), 31 rooms, under construction 164.Hotel Istra Brijuni, Brijuni, 9 rooms 165.Hotel Parentium, Poreč, 266 rooms 166.Hospicij i svećenički dom, Rijeka, 15 rooms 167.Hotel Park (ex Bosna), Doboj (BIH), 113 rooms 168.Hotel Amabilis, Selce, 33 rooms, 5 access controls 169.Hotel Ziya, Podgorica (MNE), 29 rooms 170.Hotel Lopar, TN San Marino (Lopar), 88 rooms 171.Hotel Pervan, Međugorje (BIH), 40 rooms 172.Stanovi Podgorica, Podgorica (MNE) 173.Telemont upravna zgrada, Podgorica (MNE) 174.Hotel Punta, Veli Lošinj, 238 rooms 175.Apartmani Antea, Dubrovnik, 16 apartments 176.Hotel Amazona, Prishtina (Kosovo), 30 rooms 177.Hotel Materada, Poreč, 425 rooms 178. Hotel San Fior, apart. Casa, 151 rooms 179.Hotel Argosy, Dubrovnik, 308 rooms 180.Hotel Devet, Zagreb, 21 rooms 181.Klinički bolnički centar Podgorica, 70 rooms 182.Hotel Biokovo, Makarska, 53 rooms 183.Rehabilitacijski centar Biokovka, Makarska, 51 rooms 184.Vila Dalmacija (Thalassotherapia Crikvenica), Crikvenica, 51 rooms 185.Hotel Sol Umag, depadansa Park, Umag, 86 rooms 186.Hotel Aurel, Podgorica, Crna Gora, 55 rooms 187.Hotel Sunčani Trg, Paraćin, Srbija, 24 rooms 188.Hostel Tresor, Ljubljana, Slovenija, 104 beds 189.Apartmani Fab Live (Budva, Monte Negro), 271 Ap 190.Rezidencijalna villa (Reževići, Monte Negro), 30 rooms 191.Hotel Stari Grad, Dubrovnik, 9 rooms 192.Hotel Pansionat Juznij, Sochi (Russia), 220 rooms, under construction 193.Hotel Astarea, Mlini, 39 Ap 194.Hostel Like, Zagreb, 16 rooms 195.Hotel Jump In, Beograd (Serbia), 49 rooms, under construction 196.Villa Deneš, Lovran, 12 rooms, under construction 197.Atlanska stanovi, Dubrovnik, 33 ap, under construction 198.Hotel Garden, Zagreb, 33 rooms 199.Hotel Camp San Marino, Lopar, 19 Soba 200.Hotel Bellavista, Međugorje (BIH), 69 rooms, under construction 201.Hotel Kalelarga, Zadar, 10 rooms 202.Hotel Quercus, Međugorje (BIH), 43 rooms 203.Hotel Luna, Međugorje (BIH), 96 rooms 204.Hotel Cesarica, Međugorje (BIH), 25 rooms 205.Hotel Franca, Bijelo Polje (Monte Negro), 30 rooms, under construction 206.Hotel Delfin, Bijela (Monte Negro), 120 rooms References by star rating 5 ***** ●Hotel President Dubrovnik (293 rooms) ● Hotel Lone Rovinj (265 rooms) ● Hotel Coral Umag (250 rooms) ●Hotel Admiral Slano (245 rooms) ● Hotel Ambasador Opatija (228 rooms) ● Hotel Excelsior Dubrovnik (170 rooms) ● Hotel Swiss Diamond Prishtina (160 rooms) ● Hotel Monte Mulini Rovinj (140 rooms) ● Hotel Atrium Split (127 rooms) ● Hotel Radon Plaza Sarajevo (116 rooms) Hotel Bellevue Dubrovnik (93 rooms) ● Ville Dubrovnik i Kolin Dubrovnik (56 rooms) ● Hotel Importane Royal Princes ( 50 Appartmans) ● Hotel Amabilis Selce (33 rooms) ● Hotel Milenij Opatija (50 rooms) ● Hotel Ziya Podgorica (29 rooms) ● Villa Excelsior Dubrovnik (10 rooms) ● Villa Astra Lovran (8 rooms) 4 **** (only hotels over 200 rooms) Amarin Rovinj (460 App) ●Materada Poreč (425R) ● Vespera Mali Lošinj (422R) ● Aurora Mali Lošinj (400R) ●Valamar Lacroma Resort Dubrovnik (401R) ●Valamar Club Dubrovnik (338R) ●ArgosyDubrovnik (308R) ●Mediteran Poreč (332R) ●TN Belvedere Vrsar (330 App) ●Istra Rovinj Crveni Otok (326R) ●Eden Rovinj (330R) ●Maestral Novigrad (320R) ● Valamar Club Tamaris Poreč (316R) ● Istra Garden Umag (293R) ● TN Zaton Zadar (271App ) ● Dubrovnik Zagreb (260R) ● Kolovare Zadar (250R) ● Punta Veli Lošinj (238R) ● Zagreb Poreč (230R) Well Tuhelj (225R) ● Hotel Pansionat Južnij Sochi-Adler (220R) ● TN Petalon Vrsar (224App ) ● Hotel Diamant Poreč (244R) ●Grand Hotel Orebić Orebić (205R) ●TN Hotel chains Hotel Bristol Kampinski Shaza Sarajevo (186R) ● Hotel Radisson Blue Split (181R) ● Hilton Zagreb (152R) ● Holiday Inn Beograd (140R) ● Atrium Split (128R) Splendia luxury&character hotels ● ADRIA Smart Room is installed in over 220 hotels (over 20.000 rooms) in 9 countries!