UNISync 5G-A - FEI

Transcription

UNISync 5G-A - FEI
UNISync 5G-A
Reliability
Durability
Survivability
UNISync 5G-A (FE-5200A)
Adaptability
TIMING
NEXT
Cost
GENERATION
NETWORKS...
Efficiency
U NI S y nc 5 G- A - H I-C apacity, Mi c r o - P r o c e s s o r Co n t r o l l e d , Ca r r i e r C la s s SSU
UNISync 5G-A (FE-5200A)
FEATURES
• 160 Main Shelf Outputs
• Total System Capacity
— 1440 Outputs
• DS-1/CC Combo
Output Modules
• Port Level Output
Programmability
• 10 Input Capacity
• Provision Input Signal
Formats in Software
• Input Performance
Monitoring
• Independent Clock
BYPASS Module
• NTP Server Module
w/ Optical and Gig
Ethernet
Total Software Management
The UNISync 5G-A Value Proposition
For the first time NO hardware assemblies,
The UNISync 5G-A beats the
• PTP/IEEE-1588
Grand Master Module
w/ Optical and Gig
Ethernet
jumpers, or switches are used to configure
competition with:
common telecom signal formats in the UNISync
•
• Fast, Easy System
Installation and
Provisioning
All software management interfaces are
5G-A – inbound or outbound.
UNISync 5G-A – 160
Competition – 140
Remote Management
•
full utilization of Centralized Network Operations
(CNOC)
for
alarm
monitoring
eliminates stranded ports
•
Superior source diversity with
matching 40 port capacity on
and management.
4 card groups
Microprocessor Control & Memory Features
•
Superior efficiency in managing office
The UNISync 5G-A operates with Intel™
cuts with output groups of 10
microprocessors on the COM and both IOP
corresponding to the DCD TOCA and
modules.
The COM module is the primary
home for all system databases, but database's
are
backed
up
to
both
IOP
modules.
Microprocessors on the output modules enable
provisioning and alarm management to the
port level.
2
Superior port utilization:
port programmability reduces or
remotely accessible via TCP/IP LAN allowing
Center
Superior main shelf port capacity:
www.fei-zyfer.com
TOTA modules
•
Superior input flexibility – all inputs
may be software provisioned for a
variety of signal formats
Customer Solutions, Easily Configured
UNISync 5G-A Rubidium IOP Module
System Software Control Features
The UNISync 5G-A operates with a standard
TL-1 software management interface.
All
modules auto-provision during installation and
initialization. In the event a module is replaced
by
a
maintenance
spare,
the
system
automatically performs both hardware and
software compatibility checks, downloads any
needed software, and provisions the modules
identically to the module it replaced. Record
keeping is simplified by entering output port
assignments and input reference sources in
assignable data fields.
Software storage of
CLEI codes and Mfg Serial numbers aid field
servicing and PCN administration.
Oscillator Options
UNISync 5G-A IOP modules are operated with
either the Standard Quartz ST-3E or the
Rubidium ST-2 oscillators.
The system
supports both mixed stratum operation (ST3E/
ST2) as well as matched stratum levels.
Sub-Tending/Remote Clock Operation
Any main shelf system can be used as a
BY-PASS
10
1
INPUT 1
PROGRAMMABLE
2
INPUT 2
INPUTS
3
INPUT 3
4
INPUT 4
5
INPUT 5
DS1/SF
DS1/ESF
E1 2MHz
E1 2Mbit/s
1/5/10MHz
CC ( INPUT 1 AND 2 )
6
INPUT 6
7
INPUT 7
8
INPUT 8
9
INPUT 9
10
INPUT 10
INPUT 1
IOP 1
OUTPUT
CARD 2
CLOCK
CARD 1
-48VB
POWER
SUPPLY
A
INPUT 3
POWER
SUPPLY
B
INPUT 5
INPUT 7
INPUT 8
INPUT 9
INPUT
CONNECTION
PANEL
INPUT 10
OUTPUT
CONNECTION
PANEL 1
40
OUTPUTS
master or sub-tending clock merely by
changing in software the provisioning of
input 1 and 2. SSM's can be transmitted to
OUTPUT
CONNECTION
PANEL 2
40
OUTPUTS
downstream NE's through the sub-tending
clock if needed. The sub-tending clock has
its own IP address for both remote
management and alarm surveillance and
IOP 2
OUTPUT
CARD 5
OUTPUT
CARD 6
retains the protection of BYPASS.
OUTPUT
CONNECTION
PANEL 3
40
OUTPUTS
Alarm Reporting Modes
The UNISync 5G-A reports system and
INPUT 4
INPUT 6
OUTPUT
CARD 3
OUTPUT
CARD 4
INPUT 2
-48VA
OUTPUT
CARD 1
CLOCK
CARD 2
OUTPUT
CARD 7
OUTPUT
CARD 8
OUTPUT
CONNECTION
PANEL 4
MANAGEMENT
CARD
CRAFT ALARM ALARM
IN
OUT
40
OUTPUTS
module alarms via visual LED indicators,
TL-1 Autonomous Output (AO) messaging,
LAN
and through contact closure terminals.
Everything is alarmed including expansion
shelf
umbilical
cables
and
the
BYPASS module.
3
UNISync 5G-A PRODUCT SPECIFICATIONS
UNISync 5G-A SHELF MODULES
INPUT/OUTPUT CAPACITY
Power Supply Modules
UNISync 5G-A Inputs
•
•
•
•
Dual load sharing
Each receives power from a dedicated
back panel power input
Automatic redundancy in case of
module failure
Front panel fuses and power
status LED's
Communications Module
•
•
•
•
•
UNISync 5G-A System CPU
System Communications Controller BOTH external and internal
Com processes
Provides system TL-1 Agent
Manages all system security processes
Manages all database storage, access,
and synchronization with IOP back up
Input/Output/Processor Module
•
•
•
Dual Clock Modules
Input Capacity - Up to 10 inputs
Dual System database Back Up to the
Com module
Output Module
•
•
•
•
Paired in adjacent slots for 1 to 1
output protection
Outputs are software assignable for
DS-1/CC
Inventory Port Assignments in Software
Alarm visibility to the port level
•
•
•
•
•
•
•
•
Slot compatible - Main/Exp
Back Panel I/O Fixture Adapts to Existing
DB-25 Sockets
Gigabit Ethernet Interface
NTP v 4.2.4
PTP IEEE-1588 Module
•
•
•
•
Slot compatible - Main/Exp
Back Panel I/O Fixture Adapts to Existing
DB-25 Sockets
Gigabit Ethernet Optical SFP - Front
Electrical Outputs - Rear
www.fei-zyfer.com
Sales:
Main:
714-933-4002
Fax:
714-933-4001
E-mail:
[email protected]
UNISync 5G-A Outputs
•
•
•
•
40 outputs per module, paired for 1 to
1 protection
Main shelf capacity - 160 outputs
Expansion capacity - 4 expansion shelves,
320 outputs per shelf
Total system capacity - 1440 outputs
PERFORMANCE MONITORING
•
•
•
Simultaneous Data Collection on all Inputs
Data Metrics - Frequency Offset, TIE, MRTIE,
TDEV, LMRTIE
Average Periods-from 10 to 100,000 seconds
Technical Support:
24/7:
877-700-US5G
877-700-8754
(USA only)
Main:
714-933-4002
Fax:
714-933-4001
E-mail:
[email protected]
COMMUNICATION AND MANAGEMENT
Craft/Local Ports
•
1 on front (Com Module), 2 on Rear Panel
Remote Management
•
•
NTP Client/Server Module
•
•
Termination - Wire wrap on back panel
Bridged - Each input to both IOP modules
Inputs are software assignable CC,
DS-1 (SF/ESF), E-1, 1, 5, or 10 MHz
User Selectable Priority Options - Priority 1
to 10
Up to 10 Inputs each IOP module
Selectable SSM activation - Gen 1 or Gen 2
7321 Lincoln Way
Garden Grove, CA 92841
1 RJ-45 Ethernet
3-pin terminations for output alarms - 3 Major,
3 Minor (NC/NO)
Software Interface
•
•
Standards compliant TL-1 agent
GUI interface
Standards Compliance
•
•
NEBS Level III - testing and evaluation by
Telcordia Labs
All Telecordia GR standards covering TSG’S,
oscillators and network equipment - validated
by Telcordia Labs
417-8100C