DR 068 Regenerative Blower
Transcription
DR 068 Regenerative Blower
DR 068 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 12.6 SCFM Maximum pressure: 17.2 IWG Maximum vacuum: 1.2" Hg (16.4 IWG) Standard motor: 1/16 HP, TEFC Cast aluminum blower housing, impeller & cover; slip-on steel flanges • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Cast iron (threaded) or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • • • • • • • Flowmeters reading in SCFM Filters & moisture separators Pressure gauges, vacuum gauges & relief valves Switches – air flow, pressure, vacuum or temperature External mufflers for additional silencing Air knives (used on blow-off applications) Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 0.125 AIR FLOW RATE (M3/MIN) 0.250 0.125 0.375 21 1.5 250 9 50 Hz 6 1.0 0.5 INCHES OF WATER 60 Hz INCHES OF MERCURY 15 12 3 B-1 2 4 6 8 10 12 250 -9 -6 14 15 0 150 100 50 45 30 15 0 150 100 50 0 30 30 10 0 2 4 6 8 10 AIR FLOW RATE (SCFM) 0 20 50 Hz 0 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 30 60 Hz -12 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C Rev. 2/01 -15 -3 0 45 500 -18 MM OF WATER INCHES OF WATER PSIG SUCTION 500 18 0.25 0.375 20 10 0 12 14 MM OF WATER PRESSURE 0.75 0.50 0.250 -21 DR 068 Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .X ± .08 2 (UNLESS OTHERWISE NOTED) DIMENSIONS: 1 LOCATION OF CAPACITOR ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR068DJ9Y 037143 TEFC – CS 1/16 115/208-230 Single - 60 Hz B 1.8/1.0-0.9 1.0 8.7/4.35 0.85/0.43 00/00 11 lb (5.0 kg) Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-2 DR 083 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 18.4 SCFM Maximum pressure: 24 IWG Maximum vacuum: 1.7" Hg (23.2 IWG) Standard motor: 1/8 HP, TEFC Cast aluminum blower housing, impeller & cover; slip-on steel flanges • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Cast iron (threaded) or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • • • • • • • Flowmeters reading in SCFM Filters & moisture separators Pressure gauges, vacuum gauges & relief valves Switches – air flow, pressure, vacuum or temperature External mufflers for additional silencing Air knives (used on blow-off applications) Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 0.250 25 PRESSURE 1.5 15 60 Hz 250 50 Hz 1.0 0.5 Rev. 2/01 B-3 5 10 SUCTION 500 -15 60 Hz 250 -10 50 Hz 15 20 0 15 0 150 100 50 45 30 15 0 150 100 50 0 0 30 30 20 10 0 5 10 15 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT TEMP RISE °C WATTS AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C BLOWER AIR TEMP RISE °C POWER INPUT WATTS MOTOR WINDING TEMP RISE °C 0 30 0.500 -5 5 45 0.375 -20 INCHES OF WATER 500 10 0.250 -25 INCHES OF MERCURY 0.25 0.125 MM OF WATER 0.50 AIR FLOW RATE (M3/MIN) 0.500 20 INCHES OF WATER PSIG 0.75 0.375 20 10 0 20 MM OF WATER 0.125 DR 083 Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .X ± .08 2 (UNLESS OTHERWISE NOTED) DIMENSIONS: MODEL L (IN) L (MM) DR083DC9 8.9 227 DR083DC33 8.9 227 1 LOCATION OF CAPACITOR ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR083DC9Y 036862 TEFC – CS 1/8 115/208-230 Single - 60 Hz B 1.8/1.0-0.9 1.0 8.7/4.35 1.18/0.59 00/00 14 lb (6.4 kg) Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-4 DR 101M & CP 101M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 29 SCFM Maximum pressure: 32 IWG Maximum vacuum: 2.1" IHG (28.5 IWG) Standard motor: .25 HP, TEFC Cast aluminum blower housing, diecast impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 0.25 0.5 AIR FLOW RATE (M3/MIN) 0.25 0.75 PRESSURE 30 15 50 Hz 250 10 5 10 15 20 25 -20 300 200 100 30 20 10 0 50 Hz -10 250 -5 0 30 5 10 15 20 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 70 60 50 40 20 500 60 Hz -15 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C 1.0 0.5 5 0 B-5 1.5 INCHES OF WATER 60 Hz INCHES OF MERCURY 500 20 70 60 50 40 20 300 200 100 30 20 10 0 25 30 MM OF WATER -25 MM OF WATER INCHES OF WATER PSIG 0.25 Rev. 2/01 750 2.0 25 0.5 0.75 SUCTION -30 750 1.0 0.75 0.5 DR 101M & CP 101M Regenerative Blower Scale CAD drawing available upon request. L (IN/MM) MODEL IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) DR101DC9M 9.43 / 239.5 DR101BX9M 11.1 / 281.9 DR101BX72M 11.1 / 281.9 DR101BX86M 11.1 / 281.9 A .87 INCH DIAMETER CONNECTOR HOLE B CAPACITOR LOCATION ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR101DC9M 038939 TEFC – CS 0.125 115/208-230 Single - 60 Hz B 1.8/1.0-0.9 1.0 8.7/4.35 1.78/.89 00/00 22 lb (10 kg) DR101BX9M 038936 TEFC – CS 0.25 115/230 Single - 60 Hz F 4.2/2.1 1.35 16.4/8.2 3.8/1.9 00/00 31 lb (14 kg) DR101BX72M 038937 TEFC – CS 0.25 200-230/460 Three - 60 Hz F 1.3-1.2/0.6 1.25 6.4-5.8/2.9 1.30/.65 00-00/00 31 lb (14 kg) DR101BX86M 038938 TEFC – CS 0.25 575 Three - 60 Hz F 0.6 1.25 4.2 0.4 00 58 lb (26 kg) CP101FB91MLR 038225 ChemTEFC – SS Same as DR101BX72M – 038937 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-6 DR 202M & CP 202M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 52 SCFM Maximum pressure: 35 IWG Maximum vacuum: 2.5" Hg (35 IWG) Standard motor: .33 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 1 0.5 1 PRESSURE 50 Hz 250 10 Rev. 2/01 B-7 10 20 30 40 1 60 Hz 50 Hz 50 40 20 500 400 300 200 100 60 40 20 0 10 20 30 40 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 60 250 0 AIR FLOW RATE (SCFM) 80 500 -20 -10 BLOWER AIR TEMP RISE °C BLOWER AIR TEMP RISE °C POWER INPUT WATTS MOTOR WINDING TEMP RISE °C 0 750 -30 2 INCHES OF WATER 500 INCHES OF MERCURY INCHES OF WATER PSIG 0.5 60 Hz 20 MM OF WATER 750 30 1.0 SUCTION 80 60 40 20 500 400 300 200 100 60 40 20 0 50 MM OF WATER 0.5 AIR FLOW RATE (M3/MIN) DR 202M & CP 202M Regenerative Blower Scale CAD drawing available upon request. 11.62 295.1 9.63 244.6 ROTATION DIRECTION .87 DIA. 22.1 4.00 101.6 3.18 80.8 A 5.18 131.6 10.0 254 ± 3.0 5.03 127.8 ± 1.5 1.440 36.6 ± 2.3 2.52 64.0 3.27 83.1 .398 DIA. (4X) 10.1 .44 11.2 3.94 100.1 ± 2.3 8.12 206.2 8.91 226.3 11.3 287.0 ± 3.0 1 1/4" NPSC THREAD IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) A CAPACITOR LOCATION ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR202Y9M 080564 TEFC – CS .33 115/230 Single - 60 Hz F 4.2/2.1 1.35 16.4/8.2 4.6/2.3 00/00 39 lb (17.7 kg) DR202Y72M 080565 TEFC – CS .33 230/460 Three - 60 Hz F 1.2/0.6 1.35 6.4/3.2 1.54/0.77 00/00 35 lb (15.9 kg) DR202Y86M 080566 TEFC – CS .33 575 Three - 60 Hz F 0.5 1.35 2.6 0.57 00 34 lb (15.4 kg) CP202AE72MLR — ChemTEFC – CS CP202FA91MLR — ChemTEFC – SS Same as DR202Y72M 080565 except add Chemical Processing (CP) features from catalog inside front cover Same as DR202Y72M 080565 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-8 DR 303M & CP 303M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 55 SCFM Maximum pressure: 50 IWG Maximum vacuum: 3.4" Hg (46 IWG) Standard motor: 0.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 0.5 1.0 1.5 55 2.0 PRESSURE 0.5 750 60 Hz 25 500 50 Hz 15 3 2 INCHES OF WATER 1000 35 INCHES OF MERCURY 0.5 2.0 SUCTION 1 1000 -35 750 60 Hz -25 500 50 Hz -15 250 250 5 -5 30 40 50 60 0 70 POWER INPUT WATTS 20 10 20 30 40 50 60 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 40 60 50 40 30 20 B-9 20 BLOWER AIR TEMP RISE °C 60 600 500 400 300 200 Rev. 2/01 10 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C 0 80 1250 -45 MM OF WATER INCHES OF WATER PSIG 1.0 1.5 1250 45 1.5 1.0 -55 4 80 60 40 20 600 500 400 300 200 60 50 40 30 20 70 MM OF WATER 2.0 AIR FLOW RATE (M3/MIN) DR 303M & CP 303M Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± DIMENSIONS: A .68 INCH DIAMETER CONNECTOR HOLE .08 2 (UNLESS OTHERWISE NOTED) B CAPACITOR LOCATION ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR303AE9M 038841 TEFC – CS 0.5 115/230 Single - 60 Hz F 6.2/3.1 1.25 21/10.5 6/3 0/00 40 lb (18.2 kg) DR303AE72M 038842 TEFC – CS 0.5 208-230/460 Three - 60 Hz F 1.3-1.2/0.6 1.25 10-9.2/4.6 1.63/0.83 00/00 36 lb (16.3 kg) DR303AE86M 038843 TEFC – CS 0.5 575 Three - 60 Hz F 0.6 1.25 4.2 0.7 00 35 lb (15.9 kg) CP303FA91MLR 080148 ChemTEFC – SS Same as DR303AE72M – 038842 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-10 DR 353M & CP 353M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 106 SCFM Maximum pressure: 46 IWG Maximum vacuum: 3.16" Hg (43 IWG) Standard motor: 3/4 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 1.0 1.5 2.0 2.5 3.0 0.5 1250 50 1.0 1.5 2.0 2.5 1250 PRESSURE 500 20 50 Hz 20 40 60 80 100 60 Hz 50 Hz 50 25 1250 1000 750 100 75 50 25 1250 1000 750 500 500 90 60 60 30 0 20 40 60 80 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 75 250 0 120 AIR FLOW RATE (SCFM) 100 500 -20 -10 BLOWER AIR TEMP RISE °C BLOWER AIR TEMP RISE °C POWER INPUT WATTS MOTOR WINDING TEMP RISE °C 0 750 -30 -1.0 250 10 B-11 -2.0 1000 -40 INCHES OF WATER 750 INCHES OF MERCURY 60 Hz 30 0.5 Rev. 2/01 -3.0 1000 MM OF WATER 1.0 SUCTION 40 INCHES OF WATER PSIG 1.5 3.0 -50 40 20 0 100 120 MM OF WATER 0.5 AIR FLOW RATE (M3/MIN) DR 353M & CP 353M Regenerative Blower 13.44 341.4 Scale CAD drawing available upon request. 11.44 DIA. 291 5.55 141 A ROTATION DIRECTION 5.22 132.6 4.12 104.6 B 12.22 310.4 6.19 157 3.15 80 3.75 95.3 .47 DIA. 11.9 (4) MTG HOLES 1.69 42.9 5.12 128.5 IN MM TOLERANCES: .X ± .08 2 (UNLESS OTHERWISE NOTED) DIMENSIONS: .37 9.4 8.93 226.8 1 1/2 - 11 1/2 NPSC THREAD BOTH PORTS 12.84 344.2 .41 10.4 7.16 DIA. 181.2 10.18 258.6 A TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. B LOCATION OF CAPACITOR ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR353BR9M 080554 TEFC – CS 0.75 115/230 Single - 60 Hz F 10.0/5.0 1.15 59.6/29.8 7/3.5 0/00 54 lb (24.5 kg) DR353BR72M 080555 TEFC – CS 0.75 230/460 Three - 60 Hz F 3.0/1.5 1.25 15.2/7.6 3.6/1.8 00/00 42 lb (19.1 kg) DR353BR86M 080556 TEFC – CS 0.75 575 Three - 60 Hz F 0.96 1.25 6.1 1.0 00 42 lb (19.1 kg) CP353BR72MLR — ChemTEFC – CS CP353FD72MLR — ChemTEFC – SS Same as DR353BR72M 037148 except add Chemical Processing (CP) features from catalog inside front cover Same as DR353BR72M 037148 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-12 DR 404M & CP 404M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 105 SCFM Maximum pressure: 56 IWG Maximum vacuum: 3.6" Hg (49 IWG) Standard motor: 1.0 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 0.5 1.0 1.5 2.0 2.5 AIR FLOW RATE (M3/MIN) 3.0 0.5 60 750 50 Hz 20 500 10 250 3 2 1250 -40 1000 60 Hz 750 -30 50 Hz -20 500 -10 250 1 20 40 60 80 100 0 100 75 50 25 0 1500 1000 500 100 75 50 25 0 1500 1000 500 0 0 60 60 40 20 0 20 40 60 80 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C 3.0 SUCTION INCHES OF WATER 30 INCHES OF MERCURY 60 Hz 0 B-13 2.5 -50 MM OF WATER INCHES OF WATER PSIG 1000 40 0.5 Rev. 2/01 2.0 4 1250 50 1.0 1.5 40 20 0 100 MM OF WATER PRESSURE 2.0 1.5 1.0 -60 DR 404M & CP 404M Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± L (IN) ± .30 L (MM) ± 8 .08 2 TOLERANCE: .XXX ± .030 .800 DR404AL58M 14.50 368 DR404AL72M 13.50 343 DR404AL86M 13.50 343 (UNLESS OTHERWISE NOTED) CP404CU72MLR 13.50 345 DIMENSIONS: MODEL A CAPACITOR LOCATION TEFC, 1 PHASE MOTORS B CONDUIT BOX LOCATION XP MOTOR CONTAINS .75 INCH PIPE TAP CONNECTOR HOLE C TERMINAL BOX TEFC MOTOR .87 INCH CONNECTOR HOLE SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR404AL58M 037407 TEFC – CS 1.0 115/230 Single - 60 Hz F 11.4/5.7 1.15 70/35 14.5/7.25 0/00 64 lb (29 kg) DR404AL72M 037406 TEFC – CS 1.0 230/460 Three - 60 Hz F 3.0/1.5 1.15 21/10.5 4.0/2.0 00/00 60 lb (27 kg) DR404AL86M 037408 TEFC – CS 1.0 575 Three - 60 Hz F 1.2 1.15 7.6 1.4 00 60 lb (27 kg) CP404CU72MLR 038233 ChemTEFC – SS Same as DR404AL72M – 037406 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-14 DR 454M & CP 454M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 127 SCFM Maximum pressure: 65 IWG Maximum vacuum: 4.3" Hg (58.5 IWG) Standard motor: 1.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 1.0 2.0 3.0 AIR FLOW RATE (M3/MIN) 4.0 1.0 70 2.5 2.0 PRESSURE 2.0 60 Hz 30 750 50 Hz 20 500 -50 1250 25 1000 -40 60 Hz -30 750 50 Hz -20 500 -10 250 50 75 100 125 150 0 100 75 50 25 2000 1500 1000 100 75 50 25 2000 1500 1000 500 500 90 90 60 30 0 25 50 75 100 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS 2 250 0 BLOWER AIR TEMP RISE °C 3 1 10 B-15 1500 60 30 0 125 150 MM OF WATER 1000 INCHES OF WATER 40 INCHES OF MERCURY 1250 MM OF WATER 50 0.5 Rev. 2/01 -60 4 INCHES OF WATER PSIG 1.0 4.0 SUCTION 1500 60 1.5 3.0 -70 5 DR 454M & CP 454M Regenerative Blower Scale CAD drawing available upon request. L 4.34 110.2 12.55 DIA. 318.8 A 5.10 129.6 4.82 122.4 ROTATION DIRECTION 4.12 104.6 B 13.57 ± .19 344.7 ± 5 D 6.98 177.3 3.21 81.5 1.78 45.2 4.50 114 12.52 ± .19 318 ± 5 IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) C .42 10.7 1.92 48.8 .59 DIA. (6) MTG HOLES 15.0 1 1/2" NPSC THREAD A TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. B CAPACITOR LOCATION ON SINGLE PHASE MOTORS C DIMENSION TAKEN FROM LARGE END OF DRAFT ANGLE 4.75 120.7 10.30 261.2 11.48 REF 291.2 MODEL DR454R58M DR454R72M DR454R86M CP454EZ72MLR CP454R72MLR C L (IN) 14.53 12.54 13.53 12.54 12.54 L (MM) 369.1 318.5 343.7 318.5 318.5 D (IN) D (MM) 7.16 6.83 7.16 6.83 6.83 181.9 173.5 181.9 173.5 173.5 SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Inrush Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR454R58M 080481 TEFC – CS 1.5 115/230 Single - 50/60 Hz F 15.6/7.8 1.15 84/42 19/9.5 1/0 76 lb (35 kg) DR454R72M 080480 TEFC – CS 1.5 230/460 Three - 50/60 Hz F 4.6/2.3 1.15 32/16 6.2/3.1 0/00 71 lb (32 kg) DR454R86M 080482 TEFC – CS 1.5 575 Three - 60 Hz F 1.8 1.15 12.8 2.1 00 66 lb (30 kg) CP454EZ72MLR 080491 ChemTEFC – SS Same as DR454R72M 080480 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-16 DR 513 & CP 513 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 78 SCFM Maximum pressure: 88 IWG Maximum vacuum: 5.5" Hg (74.8 IWG) Standard motor: 1.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 1.0 100 AIR FLOW RATE (M3/MIN) 2.0 1.0 PRESSURE 90 2500 -100 6 60 Hz 1000 40 30 50 Hz 4 2 INCHES OF WATER 50 INCHES OF MERCURY 1500 MM OF WATER INCHES OF WATER PSIG 1.0 70 60 500 20 20 40 60 60 Hz -30 50 Hz 25 2000 1500 1000 100 75 50 25 2000 1500 1000 500 90 90 30 0 20 40 60 AIR FLOW RATE (SCFM) 500 60 500 0 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 50 1000 -40 80 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-17 -50 AIR FLOW RATE (SCFM) 75 1500 -60 -10 0 Rev. 2/01 -70 -20 10 100 2000 -80 60 30 0 80 MM OF WATER 2000 80 2.0 2500 SUCTION -90 3.0 2.0 DR 513 & CP 513 Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) MODEL L (IN) L (MM) DR513R58 14.7 373 DR513R72 13.7 348 DR513R86 13.7 348 CP513EZ72LR 13.7 348 1 TERMINAL BOX CONNECTION .09 INCH DIAMETER ON TEFC MOTORS 2 LOCATION OF CAPACITOR ON SINGLE PHASE MOTORS AND TERMINAL BOX ON XP MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR513R72 037217 TEFC – CS 1.5 230/460 Three - 60 Hz F 4.6/2.3 1.15 43/21 4.8/2.4 00/00 86 lb (39 kg) DR513R58 037209 TEFC – CS 1.5 115/230 Single - 60 Hz F 16.8/8.4 1.15 120/60 18.2/9.1 1/0 90 lb (41 kg) DR513R86 037773 TEFC – CS 1.5 575 Three - 60 Hz F 1.8 1.5 13 1.85 00 86 lb (39 kg) CP513EZ72LR 038241 ChemTEFC – SS Same as DR513R72 – 037217 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-18 DR 505M & CP 505M Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 160 SCFM Maximum pressure: 65 or 80 IWG Maximum vacuum: 5.2" Hg (70.8 IWG) Standard motor: 2.0 or 2.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 1.0 2.0 3.0 4.0 AIR FLOW RATE (M3/MIN) 5.0 1.0 100 ▲A,B ▲B 1500 1000 40 60 Hz 50 Hz 3 B ▲ 20 40 60 80 100 1500 1000 -40 60 Hz 50 Hz 500 -20 120 140 160 180 0 3000 2000 1000 20 40 60 80 100 120 140 160 180 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C AIR FLOW RATE (SCFM) 100 75 50 25 0 2000 A,B,C,D 2 100 75 50 25 0 3000 2000 1000 0 0 80 60 40 20 0 80 60 40 20 0 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C 0 POWER INPUT WATTS 4 ▲ ▲ ▲ -60 1 0.5 BLOWER AIR TEMP RISE °C 5 C,D A 500 20 B-19 5.0 ▲-MAX SUCTION POINT A-2.0 HP (3 Phase) TEFC B-2.0 HP (1 Phase) TEFC C-2.5 HP (3 Phase) TEFC D-2.5 HP (1 Phase) TEFC -80 6 INCHES OF WATER A,C,D ▲ 60 1.0 Rev. 2/01 4.0 SUCTION 7 2000 INCHES OF MERCURY 1.5 ▲ ▲-MAX PRESSURE POINT A-2.0 HP (3 Phase) TEFC B-2.0 HP (1 Phase) TEFC C-2.5 HP (3 Phase) TEFC D-2.5 HP (1 Phase) TEFC MM OF WATER 2.0 C,D 80 INCHES OF WATER PSIG 2.5 3.0 MM OF WATER PRESSURE 3.5 3.0 2.0 -100 DR 505M & CP 505M Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) MODEL L (IN) ± .30 L (MM) ± 8 DR505CD58M 15.28 388 DR505CD72M 13.78 350 DR505AS58M 15.28 388 DR505AS72M 13.78 350 DR505AS86M 13.78 350 CP505CT72MLR 13.78 350 CP505FE72MLR 13.78 375 A .87 DIAMETER ON TEFC MOTOR 22 B CAPACITOR LOCATION ON SINGLE PHASE MOTORS C CONDUIT BOX LOCATION ON XP MOTOR. CONTAINS .75 INCH PIPE TAP SPECIFICATIONS MODEL DR505AS58M DR505AS72M DR505AS86M DR505CD58M DR505CD72M CP505FE72MLR CP505CT72MLR Part No. 037542 037543 037544 037546 037545 038239 038237 Motor Enclosure – Shaft Material TEFC – CS TEFC – CS TEFC – CS TEFC – CS TEFC – CS ChemTEFC– SS ChemTEFC– SS Horsepower 2.0 2.0 2.0 2.5 2.5 Same as Same as Voltage 1 115/230 230/460 575 115/230 230/460 DR505CD72M – DR505AS72M – 037543 037545 Phase – Frequency 1 Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz except add except add Insulation Class 2 F F F F F Chemical Chemical NEMA Rated Motor Amps 18.2/9.1 5.4/2.7 2.3 21.6/10.8 6.6/3.3 Processing Processing Service Factor 1.15 1.15 1.15 1.15 1.15 (CP) (CP) Locked Rotor Amps 138/69 38/19 21 150/75 48/24 features features Max. Blower Amps (At Cutoff) 3 24/12 7.4/3.7 3.0 26/13 10/5 from catalog from catalog inside inside Recommended NEMA Starter Size 1/0 0/00 00 1.5/0 0/0 front cover front cover Shipping Weight 83 lb (38 kg) 76 lb (35 kg) 82 lb (37 kg) 91 lb (41 kg) 82 lb (37 kg) 1 2 3 Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-20 DR 555 & CP 555 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 180 SCFM Maximum pressure: 90 IWG Maximum vacuum: 5.9" Hg (80.3 IWG) Standard motor: 4.0 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 2.0 3.0 1.0 B ▲▲ 1500 60 50 40 1000 60 Hz 50 Hz 30 20 500 4 3 2 1 10 40 ▲ ▲-MAX SUCTION POINT A-4.0 HP B-3.0 HP A B ▲ 2000 -70 A ▲ ▲B -60 1500 -50 -40 1000 -30 60 Hz 50 Hz -20 80 120 160 200 0 500 150 100 50 0 6000 4000 2000 150 100 50 0 6000 4000 2000 0 0 150 150 100 50 0 40 80 120 160 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-21 5.0 -10 0 Rev. 2/01 4.0 SUCTION -80 5 INCHES OF WATER 70 ▲B MM OF WATER INCHES OF WATER 1.0 A 3.0 -90 6 2000 INCHES OF MERCURY 80 ▲-MAX PRESSURE POINT A-4.0 HP B-3.0 HP 2.0 -100 PRESSURE A ▲ 3.0 PSIG 5.0 7 90 2.0 4.0 100 100 50 0 200 MM OF WATER 1.0 4.0 AIR FLOW RATE (M3/MIN) DR 555 & CP 555 Regenerative Blower Scale CAD drawing available upon request. MODEL L (IN) ± .30 L (MM) ± 8 DR555CK72 17.16 435.8 DIMENSIONS: DR555CK86 17.16 435.8 .08 2 TOLERANCE: .XXX ± .030 .800 DR555K72 14.65 372.1 DR555K58 15.82 401.8 DR555K86 15.78 400.8 (UNLESS OTHERWISE NOTED) CP555CS72LR 14.65 372.1 IN MM TOLERANCES: .XX ± A .87 DIAMETER ON TEFC MOTOR. .75 PIPE TAP ON XP MOTOR 22 B CAPACITOR LOCATION ON SINGLE PHASE MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72LR 037308 037310 037306 037305 037309 038245 TEFC – CS TEFC – CS TEFC – CS TEFC – CS TEFC – CS Chem TEFC – SS 4.0 4.0 3.0 3.0 3.0 Same as 230/460 575 230/460 115/230 575 DR555K72 – Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz 037306 F F F F F except add 10.4/5.2 4.1 7.6/3.8 24.9/12.4 3.6 Chemical Processing 1.0 1.0 1.15 1.0 1.0 (CP) 94/47 80 88/44 194/97 70 features 10.6/5.3 4.2 10/5 26/13 4.0 from catalog 1/0 0 0/0 1.5/1 0 90 lb (41 kg) 90 lb (41 kg) 90 lb (41 kg) 94 lb (43 kg) 90 lb (41 kg) inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-22 DR 656 & CP 656 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA CE compliant – Declaration of Conformity on file Maximum flow: 210 SCFM Maximum pressure: 106 IWG Maximum vacuum: 6.39" Hg (87 IWG) Standard motor: 4.0 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron muffler extension & flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • • • • Corrosion resistant surface treatments & sealing options Remote drive (motorless) models Slip-on or face flanges for application-specific needs Cast iron cover for additional noise resonance ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 2.0 4.0 AIR FLOW RATE (M3/MIN) 6.0 2.0 A,B 80 C,D 3000 C,D 60 60 Hz 50 Hz 1000 20 25 50 75 100 125 150 6 5 4 -100 75 50 POWER INPUT WATTS 25 5500 4500 3500 2500 1500 500 100 75 50 25 0 4000 3000 C,D A,B C,D -60 60 Hz 2000 -40 2 50 Hz 1000 -20 175 200 225 0 25 50 75 100 125 150 175 200 225 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 100 A-5.0 HP 3 ph TEFC B-4.0 HP 3 ph TEFC C-3.0 HP 3 ph TEFC D-3.0 HP 1 ph TEFC A,B -80 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C 0 B-23 2000 40 1.0 Rev. 6/01 8 4000 5000 100 75 50 25 5500 4500 3500 2500 1500 500 100 75 50 25 0 MM OF WATER A-5.0 HP 3 ph TEFC B-4.0 HP 3 ph TEFC C-3.0 HP 3 ph TEFC D-3.0 HP 1 ph TEFC 100 BLOWER AIR TEMP RISE °C PSIG INCHES OF WATER 4.0 ▲-MAX PRESSURE POINT -120 INCHES OF WATER A,B 2.0 6.0 SUCTION 5000 INCHES OF MERCURY ▲-MAX PRESSURE POINT MM OF WATER PRESSURE 120 3.0 4.0 -140 140 DR 656 & CP 656 Regenerative Blower Scale CAD drawing available upon request. 15.42 391.7 L STD. DIRECTION OF ROTATION .88 22 DIA. 7.19 DIA. 182.6 5.25 133.4 4.25 108 15.17 ± .19 384.6 ± 4.8 CAPACITOR LOCATION FOR SINGLE PHASE MODELS 7.46 189.5 4.14 105.2 5.510 129.5 15.12 ± .19 384.5 ± 4.8 .620 DIA. 15.7 (4X) MTG HOLES 2.05 ± .08 .64 52.1 ± 2 16.3 2" DIA. NPSC STRAIGHT THDS BOTH PORTS 4.92 ± .09 125 ± 2.3 11.420 290.1 12.81 325.4 L (IN) L (MM) DR656D72/86X 17.77 451.3 DR656CK72/86X 17.39 441.7 DR656K58X 17.39 441.7 MODEL IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size lb Shipping Weight kg 1 2 3 DR656CK72X 080582 DR656CK86X 080583 DR656K72X 080602 DR656K58X 080603 DR656D72X 080585 DR656D86X 080604 CP656CR72XLR 080065 TEFC – CS TEFC – CS TEFC – CS TEFC – CS TEFC – CS TEFC – CS ChemTEFC – SS 4 230/460 Three-60 Hz F 10/5 1.15 94/47 11.4/5.7 4 575 Three-50/60 Hz F 4 1.0 80 4.56 3 230/460 Three-60 Hz F 7.4/3.7 1.15 54/27 9.5/4.75 3 115/230 Single-60 Hz F 31/15.5 1.0 200/100 27.8/13.9 5 230/460 Three-60 Hz F 12.8/6.4 1.0 160/80 13/6.5 5 575 Three-60 Hz F 4.8 1.15 60 5.2 1/0 0 0/0 1.5/1 1/1 1 110 lb (243.1 kg) 110 lb (243.1 kg) 114 lb (239.4 kg) 112 lb (247.5 kg) 112 lb (247.5 kg) 114 lb (239.4 kg) 4 Same as DR656CK72X 080582 except add Chemical Processing (CP) features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 200-220 /400-440 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 6/01 B-24 DR 6 & CP 6 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 225 SCFM Maximum pressure: 110 IWG Maximum vacuum: 6.7" Hg (91.2 IWG) Standard motor: 5.0 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet muffler • Quiet operation within OSHA standards – 1 muffler included MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 4.0 80 ▲B 2000 60 Hz 60 50 Hz 40 1000 1.0 6 5 4 INCHES OF WATER ▲ ▲ -80 C ▲ 2000 A, B, C ▲ -60 60 Hz -40 1000 50 Hz 25 50 75 100 125 150 175 200 225 0 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 100 75 50 25 0 25 50 75 100 125 150 175 200 225 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS 5500 4500 3500 2500 1500 BLOWER AIR TEMP RISE °C AIR FLOW RATE (SCFM) 100 75 50 25 0 B-25 -100 3000 A-5.0 HP 3 ph TEFC B-5.0 HP 1 ph TEFC C-3.0 HP 3 ph TEFC A, B -20 0 Rev. 2/01 SUCTION 2 20 6.0 ▲-MAX SUCTION POINT 8 INCHES OF MERCURY C ▲ A, B, C 4.0 -120 MM OF WATER INCHES OF WATER PSIG 100 3000 A-5.0 HP 3 ph TEFC B-5.0 HP 1 ph TEFC C-3.0 HP 3 ph TEFC ▲A 4.0 2.0 2.0 -140 PRESSURE ▲-MAX PRESSURE POINT 120 3.0 6.0 100 75 50 25 0 5500 4500 3500 2500 1500 100 75 50 25 0 MM OF WATER 2.0 140 AIR FLOW RATE (M3/MIN) DR 6 & CP 6 Regenerative Blower Scale CAD drawing available upon request. L (IN) ± .12 L (MM) ± 3 DR6D89 18.28 464 DR6D86 18.28 464 DR6K72 18.28 464 DR6D5 22.42 569.5 CP6FF72LR 18.28 464 MODEL IN MM TOLERANCES: .XX ± DIMENSIONS: .08 2 (UNLESS OTHERWISE NOTED) 1 1.06 INCH CONNECTOR HOLE ON TEFC MOTOR .75 INCH PIPE TAP HOLE ON XP MOTOR SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 ALL PRODUCTS LISTED INCLUDE MUFFLER PN 522948 DR6D89 027578 TEFC – CS 5.0 208-230/460 Three - 60 Hz F 17.3-15.6/7.8 1.15 165-155/76 19.5-17.6/8.8 1/1 148 lb (67 kg) DR6D5 036212 TEFC – CS 5.0 230 Single - 60 Hz F 21 1.0 124 25 1.5 156 lb (71 kg) DR6D86 027579 TEFC – CS 5.0 575 Three - 60 Hz F 4.8 1.15 60 6.9 1 148 lb (67 kg) DR6K72 CP6FF72LR 027600 038253 TEFC – CS ChemTEFC – SS 3.0 Same as 230/460 DR6D89 – Three - 60 Hz 027578 F except add 13.3-12/6 Chemical Processing 1.15 (CP) 106/53 features 13.6/7.3 from catalog 1/0 inside front cover 132 lb (60 kg) HiE6D89 038071 TEFC – CS Same as DR6D89 – 027578 except add High Efficiency motor Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-26 DR 707 & CP 707 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 295 SCFM Maximum pressure: 100 IWG Maximum vacuum: 6.8" Hg (92.5 IWG) Standard motor: 5.0 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 2.0 3.0 4.0 5.0 1.0 1.0 ▲ ▲B ▲C B,C ▲ 70 60 50 1500 60 Hz 40 1000 50 Hz 30 2500 2000 20 500 10 6 5 4 3 B-27 6000 4000 8.0 ▲-MAX SUCTION POINT A-5 HP (3 Phase) TEFC B-5 HP (1 Phase) TEFC C-3 HP (3 Phase) TEFC A ▲ A ▲ ▲C -80 -70 C B ▲ ▲ 2000 ▲ -60 40 80 120 160 200 240 1500 60 Hz -50 -40 1000 50 Hz 500 -10 280 0 40 80 120 160 200 240 AIR FLOW RATE (SCFM) 100 75 50 25 8000 6000 4000 2000 2000 100 75 50 25 0 100 75 50 25 0 2500 B -20 1 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 8000 7.0 3000 -30 2 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C Rev. 2/01 25 6.0 SUCTION -90 AIR FLOW RATE (SCFM) 50 5.0 0 0 75 4.0 -100 7 0 100 3.0 -110 8 INCHES OF WATER A 2.0 -120 INCHES OF MERCURY INCHES OF WATER PSIG 2.0 80 ▲-MAX PRESSURE POINT A-5 HP (3 Phase) TEFC B-5 HP (1 Phase) TEFC C-3 HP (3 Phase) TEFC A ▲ 100 3.0 8.0 PRESSURE 110 90 7.0 MM OF WATER 4.0 6.0 3000 120 280 MM OF WATER 1.0 AIR FLOW RATE (M3/MIN) DR 707 & CP 707 Regenerative Blower DIMENSIONS: IN MM TOLERANCES: .XX ± .08 2 (UNLESS OTHERWISE NOTED) MODEL L (IN) DR707D89MX 18.17 L (MM) 461.5 DR707D5MX 19.67 499.6 DR707D86MX 18.17 461.5 DR707K72MX 18.17 461.5 CP707FF72MXLR 18.17 461.5 Scale CAD drawing available upon request. A TERMINAL BOX CONNECTION 1.06 INCH DIAMETER ON TEFC MOTORS, .75 NPT ON XP MOTORS SPECIFICATIONS MODEL DR707D89MX DR707D5MX Part No. 038704 038706 Motor Enclosure – Shaft Material TEFC – CS TEFC – CS Horsepower 5 5 Voltage 1 208-230/460 230 Phase – Frequency 1 Three - 60 Hz Single - 60 Hz Insulation Class 2 F F NEMA Rated Motor Amps 17.3-15.6/7.8 21 Service Factor 1.15 1.0 Locked Rotor Amps 165-155/76 124 Max. Blower Amps 3 19.5-17.6/8.8 25 Recommended NEMA Starter Size 1-1/0 1.5 Shipping Weight 169 lb (76.8 kg) 178 lb (81 kg) 1 2 3 DR707D86MX DR707K72MX CP707FF72MXLR HiE707D89MX 038707 038708 038720 038709 TEFC – CS TEFC – CS ChemTEFC – SS TEFC – CS 5 3 Same as 575 230/460 DR707D89MX – Same as Three - 60 Hz Three - 60 Hz 038704 DR707D89MX – F F except add 038704 4.8 13.3-12/6 Chemical except add Processing 1.15 1.15 High Efficiency (CP) 60 106/53 motor features 6.9 13.6/7.3 from catalog 0 0/0 162 lb (74 kg) 146 lb (66 kg) inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-28 DR 808 & CP 808 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 350 SCFM Maximum pressure: 116 IWG Maximum vacuum: 6.9" Hg (93.9 IWG) Standard motor: 7.5 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 3.0 4.0 5.0 6.0 ▲-MAX PRESSURE POINT A-7.5 HP B-5.0 HP 2000 60 Hz B ▲ 60 1500 B ▲ 40 1000 50 Hz 6 4 6.0 7.0 8.0 9.0 10.0 3500 ▲-MAX SUCTION POINT A-7.5 HP B-5.0 HP -100 3000 2500 A A ▲ ▲ -80 2000 B ▲ B ▲ -60 -40 1500 60 Hz 1000 50 Hz 2 500 50 100 150 200 250 300 350 0 100 50 0 10,000 7,000 5,000 150 100 50 0 10,000 7,000 5,000 2,500 2,500 150 150 100 50 0 50 100 150 200 250 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C AIR FLOW RATE (SCFM) 150 500 -20 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS 5.0 -120 2500 80 0 BLOWER AIR TEMP RISE °C 4.0 8 INCHES OF MERCURY ▲ 3000 20 B-29 3.0 -140 10 MM OF WATER INCHES OF WATER A 100 2.0 SUCTION 1.0 Rev. 2/01 1.0 PRESSURE ▲ 120 4.0 PSIG 9.0 10.0 3500 A 2.0 AIR FLOW RATE (M3/MIN) 8.0 140 5.0 3.0 7.0 100 50 0 300 350 MM OF WATER 2.0 INCHES OF WATER 1.0 DR 808 & CP 808 Regenerative Blower L (IN) L (MM) DR808AY72MX 23.23 590 DR808AY86MX 22.73 577 DR808D89MX 21.08 535 CP808FG72MXLR 22.74 578 MODEL DIMENSIONS: IN MM TOLERANCES: .XX ± .1 2.5 (UNLESS OTHERWISE NOTED) Scale CAD drawing available upon request. A TERMINAL BOX CONNECTION 1.06 INCH DIAMETER ON TEFC MOTORS .75 NPT ON XP MOTORS SPECIFICATIONS MODEL Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR808AY72MX 038722 TEFC – CS 7.5 230/460 Three - 60 Hz F 22.2/11.1 1.15 120/60 27.0/13.5 1/1 294 lb (134 kg) DR808AY86MX 038724 TEFC – CS 7.5 575 Three - 60 Hz F 7.2 1.15 60 10.8 1 262 lb (119 kg) DR808D89MX 038725 TEFC – CS 5.0 230/460 Three - 60 Hz F 17.3-15.6/7.8 1.15 152/76 17.0/8.5 1/0 294 lb (134 kg) CP808FG72MXLR HiE808AY72MX 038734 038728 ChemTEFC – SS TEFC – CS Same as DR808AY72MX – Same as 038722 DR808AY72MX – except add 038722 Chemical except add Processing High Efficiency (CP) motor features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-30 DR 858 & CP 858 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 405 SCFM Maximum pressure: 110 IWG Maximum vacuum: 7.7" Hg (104.8 IWG) Standard motor: 10 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 2000 60 Hz 60 1500 50 Hz 40 1000 1.0 2500 A, B ▲ -80 2000 60 Hz -60 1500 50 Hz -40 1000 100 200 300 400 500 80 60 40 9,000 6,000 100 80 60 40 12,000 9,000 6,000 3,000 3,000 150 150 100 50 0 100 200 300 400 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 100 500 0 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C -20 AIR FLOW RATE (SCFM) 12,000 BLOWER AIR TEMP RISE °C POWER INPUT WATTS 4 500 0 B-31 6 ▲ -100 3000 2 20 Rev. 2/01 A, B 8 2500 80 ▲-MAX SUCTION POINT A-10 HP B-7.5 HP -120 100 50 0 500 MM OF WATER INCHES OF WATER PSIG 100 SUCTION 3000 INCHES OF MERCURY ▲ ▲B A ▲ ▲B 4.0 ▲-MAX PRESSURE POINT A-10 HP B-7.5 HP MM OF WATER A 10.0 -140 10 PRESSURE 120 2.0 5.0 140 5.0 3.0 AIR FLOW RATE (M3/MIN) 10.0 INCHES OF WATER 5.0 DR 858 & CP 858 Regenerative Blower Scale CAD drawing available upon request. L MODEL DR858AY72W DR858BB72W DR858BB86W CP858FH72WLR ( ) ( ) IN MM 23.59 599 23.05 585 23.05 585 24.1 613 D IN MM 1.1 27 1.1 27 1.1 27 1.1 27 IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) SPECIFICATIONS MODEL (RAIL MOUNT) Part No. (Rail Mount) Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight Model (Base Mount) Part No. (Base Mount) 1 2 3 DR858BB72W 038740 TEFC – CS 10 230/460 Three - 60 Hz F 26/13 1.15 162/81 28/14 2/1 300 lb (136 kg) DR858BB72X 038735 DR858BB86W 038742 TEFC – CS 10 575 Three - 60 Hz F 10.5 1.15 65 11.0 1 300 lb (136 kg) DR858BB86X 038737 DR858AY72W 038738 TEFC – CS 7.5 230/460 Three - 60 Hz F 22.1/11.1 1.15 120/60 26/13 1/1 264 lb (120 kg) DR858AY72X 038736 CP858FH72WLR 038749 ChemTEFC – SS Same as DR858BB72W – 038740 except add Chemical Processing (CP) features from catalog inside front cover HiE858BB72W 038743 TEFC – CS Same as DR858BB72W – 038740 except add High Efficiency motor Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-32 DR 909 & CP 909 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 600 SCFM Maximum pressure: 125 IWG Maximum vacuum: 7.5" Hg (102 IWG) Standard motor: 15 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards when properly piped or muffled MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 6 16 14 18 20 2 ▲-MAX PRESSURE POINT A-15 HP B-10 HP ▲ 2500 60 Hz 80 2000 B ▲ 60 1500 50 Hz 40 1000 1.0 7 6 5 4 3 8 10 12 14 16 18 20 3500 ▲-MAX SUCTION POINT A-15 HP B-10 HP -120 8 MM OF WATER 100 6 SUCTION 9 3000 INCHES OF MERCURY ▲ 4 -140 10 PRESSURE A,B INCHES OF WATER PSIG 12 A 120 2.0 10 3500 4.0 3.0 8 ▲ -100 A 3000 2500 A,B ▲ B ▲ -80 2000 60 Hz -60 1500 50 Hz -40 1000 2 500 20 500 -20 1 300 400 500 600 0 700 100 50 0 12,500 7,500 2,500 100 50 0 100 200 300 400 500 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-33 200 AIR FLOW RATE (SCFM) 17,500 Rev. 2/01 100 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C 0 100 50 0 17,500 12,500 7,500 2,500 100 50 0 600 700 MM OF WATER 4 140 5.0 INCHES OF WATER 2 AIR FLOW RATE (M3/MIN) DR 909 & CP 909 Regenerative Blower Scale CAD drawing available upon request. MODEL L (IN / MM) DR909BE72W 23.69 / 602 DR909BE86W 23.15 / 588 DR909BB72W 23.2 / 589 DR909BB86X 23.2 / 589 DR909BE72X 23.69 / 602 DR909BE86X 23.2 / 589 DR909BB72X 23.2 / 589 HiE909BE72W 27.44 / 697 IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) SPECIFICATIONS MODEL (RAIL MOUNT) DR909BE72W Part No. (Rail Mount) 038620 Motor Enclosure – Shaft Material TEFC – CS Horsepower 15 Voltage 1 208-230/460 Phase – Frequency 1 Three - 60 Hz Insulation Class 2 F NEMA Rated Motor Amps 41.5-37.6/18.8 Service Factor 1.15 Locked Rotor Amps 318/159 Max. Blower Amps 3 48.6-44/22 Recommended NEMA Starter Size 2/2 Shipping Weight 400 lb (182 kg) Model (Base Mount) DR909BE72X Part No. (Base Mount) 038622 1 2 3 DR909BE86W 038625 TEFC – CS 15 575 Three - 60 Hz F 14.6 1.15 164 15.8 2 400 lb (182 kg) DR909BE86X 038626 DR909BB72W 038621 TEFC – CS 10 230/460 Three - 60 Hz F 26/13 1.15 162/81 32.4/16.2 2/1 400 lb (182 kg) DR909BB72X 038623 DR909BB86W CP909FJ72WLR HiE909BE72W 080300 038632 038633 TEFC – CS ChemTEFC – SS TEFC – CS 10 575 Same as Three - 60 Hz DR909BE72W – Same as F 038620 DR909BE72W – 10.5 except add 038620 1.15 Chemical except add Processing 65 High Efficiency (CP) 13.0 motor features 1 from catalog 400 lb (182 kg) inside front cover DR909BB86X 080183 Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-34 DR P9 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 780 SCFM Maximum pressure: 116 IWG Maximum vacuum: 6.6" Hg (89.8 IWG) Standard motor: 20 HP, ODP Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Quiet operation within OSHA standards when properly piped or muffled – 2 mufflers included MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 5.0 10.0 15.0 AIR FLOW RATE (M3/MIN) 20.0 5.0 ▲ 2500 80 2000 60 Hz 50 Hz 60 1500 40 1000 4 2500 ▲A B ▲ A ▲ -80 2000 B ▲ -60 1500 60 Hz -40 1000 50 Hz 2 20 -20 500 0 100 200 300 400 500 600 700 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C BLOWER AIR TEMP RISE °C 100 75 50 25 0 100 200 300 400 500 600 700 AIR FLOW RATE (SCFM) BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS 20,000 15,000 10,000 5,000 0 500 0 800 AIR FLOW RATE (SCFM) 100 75 50 20 0 B-35 6 -100 3000 100 75 50 20 0 20,000 15,000 10,000 5,000 0 100 75 50 25 0 800 MM OF WATER B ▲ 8 INCHES OF WATER ▲ 100 SUCTION 1.0 Rev. 2/01 20.0 ▲-MAX SUCTION POINT A-20 HP B-15 HP -120 3000 INCHES OF MERCURY B A ▲-MAX PRESSURE POINT A-20 HP B-15 HP MM OF WATER INCHES OF WATER PSIG 2.0 15.0 PRESSURE A ▲ 120 4.0 3.0 10.0 -140 140 DR P9 Regenerative Blower Scale CAD drawing available upon request. A B 1.37 INCH DIAMETER TERMINAL BOX CONNECTOR HOLE OUTLET (PRESSURE) ON DRP9BM72C INLET (SUCTION) ON DRP9BM72D IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) SPECIFICATIONS MODEL Part No. MODEL Suction Mode Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight Pressure Mode 1 2 3 ALL PRODUCTS LISTED INCLUDE 2 MUFFLERS PN 515185 DRP9BM72C 037033 DRP9BM72D 036275 ODP – CS 20 230/460 Three - 60 Hz F 52/26 1.15 306/153 55.6/27.8 3/2 456 lb (207 kg) DRP9BM86C 037040 DRP9BM86D 036276 ODP – CS 20 575 Three - 60 Hz F 20 1.15 115 22.2 2 456 lb (207 kg) DRP9BL72C 036512 DRP9BL72D 036513 ODP – CS 15 230/460 Three - 60 Hz F 36/18 1.15 256/128 48/24 2/2 390 lb (177.3 kg) Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-36 DR 979 & CP 979 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 1000 SCFM Maximum pressure: 100 IWG Maximum vacuum: 5.0" Hg (70 IWG) Standard motor: 15 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 3.5 100 1.0 2000 B ▲ 70 ▲B 1500 60 50 60 Hz 1000 40 30 50 Hz MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-37 -100 6 5 4 3 400 600 800 ▲-MAX SUCTION POINT 2000 -80 ▲ A,B▲ -70 A -60 -50 70 40 10 35,000 25,000 15,000 50 Hz 500 -10 0 1000 200 400 600 800 AIR FLOW RATE (SCFM) 100 70 40 10 35,000 25,000 15,000 5,000 100 0 1500 60 Hz 1000 100 40 ▲ -30 5,000 70 B -40 AIR FLOW RATE (SCFM) 100 2500 A - 20 HP TEFC B - 15 HP TEFC -20 1 200 3000 SUCTION -90 500 10 0 Rev. 2/01 7 2 20 0.5 -110 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 1.5 ▲A 80 2500 8 BLOWER AIR TEMP RISE °C 2.0 INCHES OF WATER PSIG 2.5 ▲-MAX PRESSURE POINT A - 20 HP TEFC B - 15 HP TEFC 90 3.0 PRESSURE ▲A 70 40 0 1000 MM OF WATER 110 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0 6.0 -120 3000 INCHES OF WATER 4.0 3.0 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0 INCHES OF MERCURY 6.0 120 MM OF WATER 3.0 AIR FLOW RATE (M3/MIN) DR 979 & CP 979 Regenerative Blower Scale CAD drawing available upon request. 19.25 9.75 488.95 247.65 7.44 188.99 25.71 ± .25 652.93 1.50 DIA. 38.10 OUT IN 4 - 8 NPSC FEMALE THREAD BOTH PORTS 2.69 68.26 6.63 168.40 19.91 505.71 A 10.25 260.35 1.67 42.41 10.54 267.65 25.65 ± .25 651.46 9.50 241.30 11.34 288.05 6.22 157.92 .75 2.00 x 19.1 50.8 (4) MOUNTING SLOTS 9.16 232.66 10.96 278.33 IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) A NOTE: USE DRAWING FOR 15 HP ONLY. USE EN979 DRAWING FOR 20 HP. TERMINAL BOX CONNECTOR HOLE 1.09 / 27.7 DIA. SPECIFICATIONS MODEL (RAIL MOUNT) Part No. (Rail Mount) Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight 1 2 3 DR979BH72W 080718 TEFC – CS 20 230/460 Three - 60 Hz H 46/23 1.15 294/147 66/33 3/2 350 lb (159 kg) DR979BE72W 080704 TEFC – CS 15 230/460 Three - 60 Hz H 37.6/18.8 1.15 290/145 44/22 2/2 300 lb (136 kg) DR979BE86W DR979BE72W 080702 080632 TEFC – CS TEFC – CS 15 15 575 230/460 Three - 60 Hz Three - 60 Hz H F 14.6 37.6/18.8 1.15 1.15 93 290/145 15.8 44/22 2 2/2 300 lb (136 kg) 300 lb (136 kg) CP979FJ72WLR — ChemTEFC – SS Same as DR979BE72W – 080704 except add Chemical Processing (CP) features from catalog inside front cover HiE979BE72W — TEFC – CS Same as DR979BE72W – 080704 except add High Efficiency motor Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 6/01 B-38 DR P13 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 1300 SCFM Maximum pressure: 122 IWG Maximum vacuum: 7.3" Hg (99.3 IWG) Standard motor: 30 HP, ODP Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Quiet operation within OSHA standards when properly piped or muffled – 2 mufflers included MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) 3500 ▲-MAX PRESSURE POINT A-30 HP B-20 HP A,B ▲ 100 80 2000 ▲B 1500 60 60 Hz 1000 50 Hz 40 3500 1.0 7 6 5 4 3 ▲-MAX SUCTION POINT A-30 HP B-20 HP -120 8 2500 12.0 16.0 20.0 24.0 28.0 32.0 36.0 SUCTION 9 3000 MM OF WATER INCHES OF WATER PSIG 2.0 PRESSURE A 8.0 -140 10 INCHES OF MERCURY ▲ 120 4.0 3.0 4.0 12.0 16.0 20.0 24.0 28.0 32.0 36.0 A -100 A,B ▲ 2500 ▲ 2000 -80 ▲B -60 60 Hz 50 Hz -40 1500 2 500 20 3000 1000 500 -20 1 600 800 1000 1200 0 1400 100 50 0 25,000 15,000 5,000 100 50 0 200 400 600 800 1000 AIR FLOW RATE (SCFM) MOTOR POWER WINDING INPUT WATTS TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-39 400 AIR FLOW RATE (SCFM) 35,000 Rev. 2/01 200 BLOWER AIR TEMP RISE °C MOTOR WINDING TEMP RISE °C 0 100 50 0 35,000 25,000 15,000 5,000 100 50 0 1200 1400 MM OF WATER 8.0 140 5.0 INCHES OF WATER 4.0 AIR FLOW RATE (M3/MIN) DR P13 Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) HP MOTOR C (IN/MM) H (IN/MM) G (IN/MM) 30 11.12 / 282 23.34 / 593 13.6 / 346 20 11.12 / 282 22.59 / 574 10.86 / 275.8 SPECIFICATIONS MODEL Part No. MODEL Suction Mode Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight Pressure Mode 1 2 3 A B 2.0 INCH DIAMETER TERMINAL BOX CONNECTOR HOLE (30 HP MOTOR) OUTLET (PRESSURE) ON DRP13BP72C INLET (SUCTION) ON DRP13BP72D ALL PRODUCTS LISTED INCLUDE 2 MUFFLERS PN 511569 DRP13BP72C 036711 DRP13BP72D 036712 ODP – CS 30 230/460 Three - 60 Hz F 78/39 1.15 380/190 84/42 3/3 687 lb (311 kg) DRP13BP86C 036923 DRP13BP86D 036924 ODP – CS 30 575 Three - 60 Hz F 28 1.15 174 36 3 687 lb (311 kg) DRP13BM72C 036708 DRP13BM72D 036707 ODP – CS 20 230/460 Three - 60 Hz F 49/24.5 1.15 306/153 72/36 3/2 592 lb (269 kg) Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 4/01 B-40 DR 14 & CP 14 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 920 SCFM Maximum pressure: 144 IWG Maximum vacuum: 8.8" Hg (119.7 IWG) Standard motor: 30 HP, TEFC Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Inlet & outlet internal muffling • Quiet operation within OSHA standards MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS 220 7.0 200 PRESSURE ▲-MAX PRESSURE POINT A-30 HP TEFC B-25 HP TEFC C-20 HP TEFC 3.0 2.0 160 MOTOR WINDING TEMP RISE °C POWER INPUT WATTS BLOWER AIR TEMP RISE °C B-41 14 -200 3500 ▲A 120 3000 ▲B 100 ▲B ▲C 80 60 2500 ▲C 2000 60 Hz 50 Hz 1500 500 200 400 600 800 12 10 8 6 4 A-30 HP TEFC B-25 HP TEFC C-20 HP TEFC -160 70 40 10 35,000 25,000 15,000 3500 -100 B,C -80 2500 ▲C 2000 60 Hz 1500 50 Hz 1000 500 -20 0 1000 200 400 600 800 AIR FLOW RATE (SCFM) 100 70 40 10 35,000 25,000 15,000 5,000 100 0 3000 -60 100 40 5000 4500 A ▲ ▲B ▲ A ▲ -120 5,000 70 5500 4000 -140 -40 2 6000 SUCTION ▲-MAX SUCTION POINT AIR FLOW RATE (SCFM) 100 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0 -180 1000 20 0 Rev. 2/01 5000 4000 ▲A 140 40 1.0 -220 BLOWER AIR TEMP RISE °C 4.0 16 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C 5.0 INCHES OF WATER PSIG 6.0 5500 4500 180 6.0 -240 6000 MM OF WATER 8.0 3.0 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0 INCHES OF WATER 6.0 240 INCHES OF MERCURY 3.0 AIR FLOW RATE (M3/MIN) 70 40 0 1000 MM OF WATER AIR FLOW RATE (M3/MIN) DR 14 & CP 14 Regenerative Blower Scale CAD drawing available upon request. MODEL DR14DW72MW DR14DW86MW DR14BH72MW DR14DT72MW CP14FK72MWLR L ( ) ( ) IN MM 31.55 801 31.55 801 29.9 759 31.68 804.7 31.55 801 D IN MM 1.98 50.3 1.98 50.3 1.38 35.1 1.98 50.3 1.50 38.1 IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) SPECIFICATIONS MODEL (RAIL MOUNT) DR14DW72MW DR14DW86MW DR14DT72MW Part No. (Rail Mount) 038750 038751 080451 Motor Enclosure – Shaft Material TEFC – CS TEFC – CS TEFC – CS Horsepower 30 30 25 Voltage 1 230/460 575 230/460 Phase – Frequency 1 Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class 2 F F F NEMA Rated Motor Amps 66/33 26.5 58/29 Service Factor 1.15 1.15 1.15 Locked Rotor Amps 430/215 172 304/152 Max. Blower Amps 3 86/43 32.8 69/34.5 Recommended NEMA Starter Size 3/3 3 3/3 Shipping Weight 696 lb (316 kg) 694 lb (316 kg) 650 lb (295 kg) 1 2 3 DR14BH72MW 038752 TEFC – CS 20 230/460 Three - 60 Hz F 46/23 1.15 294/147 66/33 3/2 600 lb (292 kg) CP14FK72MWLR HiE14DW72MW 038757 038759 ChemTEFC – SS TEFC – CS Same as DR14DW72MW – Same as 038750 DR14DW72MW – except add 038750 Chemical except add Processing High Efficiency (CP) motor features from catalog inside front cover Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-42 DR P15 Regenerative Blower FEATURES • • • • • • • Manufactured in the USA – ISO 9001 compliant CE compliant – Declaration of Conformity on file Maximum flow: 1800 SCFM Maximum pressure: 150 IWG Maximum vacuum: 8.5" Hg (115.6 IWG) Standard motor: 60 HP, ODP Cast aluminum blower housing, impeller & cover; cast iron flanges (threaded) • UL & CSA approved motor with permanently sealed ball bearings • Quiet operation within OSHA standards when properly piped or muffled – 2 inlet mufflers included MOTOR OPTIONS • International voltage & frequency (Hz) • Chemical duty, high efficiency, inverter duty or industry-specific designs • Various horsepowers for application-specific needs BLOWER OPTIONS • Corrosion resistant surface treatments & sealing options • Remote drive (motorless) models • Slip-on or face flanges for application-specific needs ACCESSORIES (See Catalog Accessory Section) • Flowmeters reading in SCFM • Filters & moisture separators • Pressure gauges, vacuum gauges & relief valves • Switches – air flow, pressure, vacuum or temperature • External mufflers for additional silencing • Air knives (used on blow-off applications) • Variable frequency drive package BLOWER PERFORMANCE AT STANDARD CONDITIONS AIR FLOW RATE (M3/MIN) ▲ 125 1800 75 50 Hz 50 600 500 1000 1500 6 4 2 70 40 10 80,000 60,000 40,000 2400 A, B ▲ 1800 -50 1200 50 Hz -25 2000 0 500 1000 600 1500 AIR FLOW RATE (SCFM) 100 70 40 10 80,000 60,000 40,000 100 BLOWER AIR TEMP RISE °C 20,000 0 60 Hz -75 100 30 3600 3000 ▲ -100 20,000 70 A, B -125 AIR FLOW RATE (SCFM) 100 ▲-MAX SUCTION POINT A-60 HP B-40 HP -150 MOTOR POWER WINDING INPUT WATTS TEMP RISE °C MOTOR WINDING TEMP RISE °C POWER INPUT WATTS 1200 25 BLOWER AIR TEMP RISE °C B-43 2400 56.0 4200 10 8 42.0 SUCTION 3600 3000 60 Hz 100 0 Rev. 2/01 B▲ 28.0 70 30 0 2000 MMOF WATER A, B ▲-MAX PRESSURE POINT A-60 HP B-40 HP INCHES OF MERCURY ▲ MM OF WATER INCHES OF WATER PSIG 1.0 14.0 -175 12 PRESSURE A 150 2.0 AIR FLOW RATE (M3/MIN) 56.0 4200 5.0 3.0 42.0 175 6.0 4.0 28.0 INCHES OF WATER 14.0 DR P15 Regenerative Blower Scale CAD drawing available upon request. IN MM TOLERANCES: .XX ± DIMENSIONS: .1 2.5 (UNLESS OTHERWISE NOTED) NOTE: 60 HP DIMENSIONS SHOWN UNLESS OTHERWISE NOTED. B SPECIFICATIONS MODEL Part No. MODEL Suction Mode Part No. Motor Enclosure – Shaft Material Horsepower Voltage 1 Phase – Frequency 1 Insulation Class 2 NEMA Rated Motor Amps Service Factor Locked Rotor Amps Max. Blower Amps 3 Recommended NEMA Starter Size Shipping Weight Pressure Mode 1 2 3 A 2.5 INCH DIAMETER TERMINAL BOX CONNECTOR HOLE (60 HP MOTOR) OUTLET (PRESSURE) ON DRP15EE72C INLET (SUCTION) ON DRP15EE72D ALL PRODUCTS LISTED INCLUDE 2 MUFFLERS PN 516264 DRP15EE72C 036956 DRP15EE72D 036958 ODP – CS 60 230/460 Three - 60 Hz F 140/70 1.15 870/435 170/85 5/4 1025 lb (465 kg) DRP15BQ72C 037243 DRP15BQ72D 037242 ODP – CS 40 230/460 Three - 60 Hz F 96/48 1.15 630/315 160/80 4/3 923 lb (419 kg) DRP15BQ86C – DRP15BQ86D – ODP – CS 40 575 Three - 60 Hz F 38.4 1.15 540/270 64 3 923 lb (419 kg) Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220 VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range. Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C. Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature. Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates. Rev. 2/01 B-44