Cable Gland Selection
Transcription
Cable Gland Selection
Cable Gland Terminations Remora Electrical Limited Introduction Company Remora Electrical Ltd was established in 1973 to distribute cable glands, junction boxes & stopping plugs, reducers & adaptors. We are conveniently located close to the M1 near Sheffield, we are the only distributor for CCG products for the mining industry. Over the last decade we have grown our mining business with the help of the mines & OEMs both in the UK & Europe. We carry comprehensive stocks of ATEX approved mining products. We also stock a range of ATEX certified adaptor plates to enable the direct fitting of our glands into a range of European manufactured motors & switchgear along with spigot adaptors. We also supply a wide range of industrial products suitable for use in the mines - this catalogue is designed for the mining industry & shows the range of products we sell. This is not our full range – if your requirements do not appear in this mining catalogue – give our knowledgeable team a call they will be able to help. All items from our UK stores are despatched overnight – for next day delivery saving you valuable time and money. If however we need to order on the factory our lead times are based on surprisingly short turn-around. The factory in South Africa has a wealth of experience working closely within its own mining industry to develop cable glands which are designed and manufactured to withstand the robust environments of the mines. The simplicity of the ‘Captive Components’ and ‘Built in Seals’ concepts means that no matter where in the world the products are being installed, the simplest of instructions will ensure that all parts have been correctly fitted. All products are manufactured to ISO 90001-2000 underwritten by Underwriters List (USA). CCG have a ATEX certificate for Group I products ECS06ATEX2044. CCG glands are also approved for Group I applications in South Africa and China as well as for Group II mines in Australia. Contents Cable Gland Selection 1 Armortex Cable Gland 2 FLP Cable Gland 3 FLP-TR Cable Gland 4 FLP-HOSE Cable Gland 5 Barrier Tex A Cable Gland 6 Barrier Tex F Cable Gland 7 CROCLOCK CR-CB Cable Gland 8 CROCLOCK CR-UB Cable Gland 9 HAS Spigot Adaptor / Reducer 10 HAP1 Motor/Switchgear Reducer 11 HAP2 Motor/Switchgear Reducer 12 HAP3 Motor/Switchgear Reducer 13 HAP4 Motor/Switchgear Reducer 14 HAP5 Motor/Switchgear Reducer 15 Motor/Switchgear Salvage Plate 16 Cable Gland Reducers / Adaptors 17 A2 Industrial Cable Gland 18 CW Industrial Cable Gland 19 IP Plus Industrial Cable Gland 20 Utility Junction Box 21 Handifit Junction Box 22 Cable Gland Accessories 23 Notes Section 24 Cable Gland Selection Remora Electrical Ltd Cable Gland Gland Selection Selection Cable We offer cable glands to cover the full range of cables including armoured and nonarmoured and applications from general industrial use through increased saftey, flameproof and explosion proof. We have only listed the cable glands specifically designed for the mining applications, a full range is available on request. Do I Need A Barrier Gland ? Should your cable be filled, mining approved and substantially compact and circular, has extruded bedding and the fillers are non-hygroscopic you may utilise a flameproof cable gland entry devices, incorporation a sealing ring greater than 20mm as per EN 50018 - 2000 Annex C. The following cable glands can fulfill this requirement:Armoured Cables Non-armoured Cables ARMORTEX FLP-TR FLP FLP-HOSE If your cable does not meet the above specification then barrier type cable glands are available and provide a compound barrier seal around the conductor and an enviromental seal on the outer sheath:Armoured Cables 1 Tel Non-armoured Cables BARRIER TEX A BARRIER TEX F CROCLOCK CR-C CROCLOCK CR-U +44 (0) 1226 352 000 www.remora.net Mining Glands Armortex Remora Electrical Ltd ARMORTEX EEx de I/IIC I M2 / II 2 GD Cable Gland The Armortex Gland is designed with the MAC Multi Armour Captive-Component, providing an armour clamp and earth bond for Steel wire, Braid, Tape & Pliable wire armoured cable. Designed for hazardous area EExde group I (mining) & group IIC (surface) applications suitable for both indoor & outdoor. Seals on both inner and outer sheaths, to IP66/67/68 when fitted with sealing gasket provided. Gland Code Size 052200A 0522-0A 052201A Entry Thread Cable Details (diameter) Min-Max ‘A’ Max ‘B’ Armour Dia Min-Max Max Length ‘E’ Hexagonal Details (max) Metric / NPT ‘C’ ‘D’ ‘Flats’ ‘Crns’ 00 - M20ss M20 ½ 15 3.0 - 8.0 13.5 0.2-1.25 73 25 28 0 - M20s M20 ½ 15 8.0 - 11.5 16.0 0.2-1.25 73 25 28 1 - M20 M20 ½ ¾ 15 11.5 - 14.0 19.0 0.2-1.25 78 30 34 052202A 2 - M25 M25 ¾ 1” 15 14.0 - 20.5 26.5 0.2-1.6 85 40 45 052203A 3 - M32 M32 1” 1¼ 15 20.0 - 26.5 33.0 0.2-2.0 95 45 51 052204A 4 - M40 M40 1¼ 1½ 20 26.5 - 32.5 40.5 0.3-2.0 105 55 62 052255A 5 - M50s M50 1½ 2” 20 32.5 - 38.0 46.0 0.4-2.5 108 74 83 052205A 5 - M50 M50 1½ 2” 20 38.0 - 44.5 52.0 0.4-2.5 108 74 83 052265A 6 - M63s M63 2” 2½ 20 44.5 - 50.0 60.0 0.4-2.5 145 82 92 052206A 6 - M63 M63 2” 2½ 20 50.0 - 56.0 67.0 0.4-2.5 145 82 92 052207A 7 - M75 M75 2½ 20 56.0 - 65.0 78.0 0.4-2.5 158 96 108 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • No need to change seals or reverse cones or cone rings to accommodate different types of armoured cable. • Captive cone and ring ensure no loose parts during assembly. • Extra long captive explosion proof seal ensures built in safety. • Armour clamp components can be inspected after installation. • Gland can be used on Exd enclosures greater than 2 litres volume. • Complete with orange thread cap / safety gauge for correct gland selection. Technical Data Type ARMORTEX Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer Cable Type Steel Wire, Braid, Tape, Pliable Wire Armour Armour Clamping Multi Armour Cone and Cone Ring Sealing Area Inner and outer sheath Accessories Spigot flange adaptors, Motor/Switchgear adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SANS / SABS IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC and DIP A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2 GD EExd I M2 EN50014:1997E DEMKO 01 ATEX 130325X EN50018:2000E EPSILON 06 ATEX 2044 EN50019:2000E EN50281-1-1:1999E Operating Temperature -30 to 130 °C Alternative Certification Options Available:• South Africa [email protected] Fax +44 (0)1226 360 510 • Chinese 2 Mining Glands FLP Remora Electrical Ltd FLP EEx de I/IIC I M2 / II 2 GD Cable Gland The FLP Gland is designed with the MAC Multi Armour Captive-Component, providing an armour clamp and earth bond for Steel wire, Braid, Tape & Pliable wire armoured cable. Designed for hazardous area EExde group I (mining) & group IIC (surface) applications suitable for indoor use. Seals on inner sheath only, to IP66/67/68 when fitted with sealing gasket provided. Entry Thread Cable Details (diameter) Gland Code Size 052100A 00 - M20ss M20 ½ 15 3.0 - 8.0 16.0 0521-0A 0 - M20s M20 ½ 15 8.0 - 11.5 16.0 Metric / NPT ‘C’ ‘D’ Min-Max ‘A’ Max ‘B’ Hexagonal Details (max) Max Length ‘E’ ‘Flats’ ‘Crns’ 46 25 28 46 25 28 052101A 1 - M20 M20 ½ ¾ 15 11.5 - 14.0 19.0 48 30 34 052102A 2 - M25 M25 ¾ 1” 15 14.0 - 20.5 26.5 60 42 47 052103A 3 - M32 M32 1” 1¼ 15 20.0 - 26.5 33.0 76 47 53 052104A 4 - M40 M40 1¼ 1½ 20 26.5 - 32.5 40.5 84 60 68 052155A 5 - M50s M50 1½ 2” 20 32.5 - 38.0 46.0 90 74 83 052105A 5 - M50 M50 1½ 2” 20 38.0 - 44.5 52.0 90 74 83 052165A 6 - M63s M63 2” 2½ 20 44.5 - 50.0 60.0 96 85 96 052106A 6 - M63 M63 2” 2½ 20 50.0 - 56.0 67.0 96 85 96 052207A 7 - M75 M75 2½ 20 56.0 - 65.0 78.0 105 96 108 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • Two part handling, freely rotating captive cone for earth continuity and armour clamping. • Factory fitted with a specially formulated elastomeric seal provides built-in safety. • Captive cone and ring ensure no loose parts during assembly. • Gland can be used on Exd enclosures greater than 2 litres volume. • Complete with orange thread cap / safety gauge for correct gland selection. Technical Data FLP Type Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer Cable Type Steel Wire, Braid, Tape, Pliable Wire Armour Armour Clamping Multi Armour Cone and Cone Ring Inner sheath Sealing Area Spigot flange adaptors, Motor/Switchgear Accessories adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SANS / SABS IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC and DIP A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2 GD EExd I M2 EN50014:1997E DEMKO 01 ATEX 130325X EN50018:2000E EPSILON 06 ATEX 2044 EN50019:2000E EN50281-1-1:1999E Operating Temperature -30 to 130 °C Alternative Certification Options Available:• South Africa 3 Tel +44 (0) 1226 352 000 • Chinese www.remora.net Mining Glands FLP-TR Remora Electrical Ltd FLP-TR EEx de I/IIC I M2 / II 2 GD Cable Gland The FLP-TR Compression Gland is designed for use with unarmoured elastomeric and plastic cables where it is necessary to provide an flameproof seal. Fitted with two specially formulated elastomeric seals. Inner seals on the cable sheath. Harder outer seal grips the cable, giving superior cable retention and IP rating. Seals on the cable outer sheath, to IP66/67/68 when fitted with sealing gasket provided. Gland Code Size 052400A 0524-0A Entry Thread Cable Details (diameter) Min-Max ‘A’ Max Length ‘E’ Metric / NPT ‘C’ ‘D’ 00 - M20ss M20 ½ 15 3.5 - 8.5 0 - M20s M20 ½ 15 8.0 - 11.5 052401A 1 - M20 M20 ½ ¾ 15 052402A 2 - M25 M25 ¾ 1” 15 052403A 3 - M32 M32 1” 1¼ 15 20.0 - 26.5 052404A 4 - M40 M40 1¼ 1½ 20 052455A 5 - M50s M50 1½ 2” 20 052405A 5 - M50 M50 1½ 2” 052465A 6 - M63s M63 052406A 6 - M63 M63 052407A 7 - M75 M75 Hexagonal Details (max) ‘Flats’ ‘Crns’ 57 25 28 57 25 28 11.5 - 14.0 59 30 34 14.0 - 20.5 71 42 47 87 47 53 26.5 - 32.5 96 60 68 32.5 - 38.0 112 74 83 20 38.0 - 44.5 112 74 83 2” 2½ 20 44.5 - 50.0 124 85 96 2” 2½ 20 50.0 - 56.0 124 85 96 2½ 20 56.0 - 65.0 134 96 108 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • Fitted with specifically formulated captive elastomeric seals, built-in safety. • No loose parts that can get lost during assembly. • Provided with an extra hard gripper seal to grip cable. • Gland can be used on Exd enclosures greater than 2 litres volume. • Complete with orange thread cap / safety gauge for correct gland selection. Technical Data FLP-TR Type Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer Cable Type Unarmoured TRS Outer sheath Sealing Area Spigot flange adaptors, Motor/Switchgear Accessories adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SANS / SABS IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC and DIP A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2 GD EExd I M2 EN50014:1997E DEMKO 01 ATEX 130325X EN50018:2000E EPSILON 06 ATEX 2044 EN50019:2000E EN50281-1-1:1999E Operating Temperature -30 to 130 °C Alternative Certification Options Available:• South Africa [email protected] Fax +44 (0)1226 360 510 • Chinese 4 Mining Glands FLP-HOSE Remora Electrical Ltd FLP-HOSE EEx de I/IIC I M2 / II 2 GD Cable Gland The FLP-HOSE Compression Gland is designed for use with unarmoured elastomeric and plastic cables where it is necessary to provide an flameproof seal. The male spigot allows protective hose to be secured at the back of the gland. Seals on the outer sheath of the cable, to IP66/67/68 when fitted with sealing gasket provided. Gland Code Size Entry Thread Metric / NPT ‘C’ ‘D’ Cable Details Min-Max ‘A’ To Suit Hose Size ‘B’ Hexagonal Details (max) ‘Flats’ ‘Crns’ 0527-0A 0 - M20s M20 ½ 15 8.0 - 11.5 ½” - 13mm 25 28 052701A 1 - M20 M20 ½ ¾ 15 11.5 - 14.0 ¾” - 19mm 30 34 052702A 2 - M25 M25 ¾ 1” 15 14.0 - 20.5 1” - 25mm 42 47 052703A 3 - M32 M32 1” 1¼ 15 20.0 - 26.5 1¼” - 32mm 47 53 052704A 4 - M40 M40 1¼ 1½ 20 26.5 - 32.5 1½” - 38mm 60 68 052765A 5 - M50s M50 1½ 2 20 32.5 - 38.0 1¾” - 45mm 74 83 052705A 5 - M50 M50 1½ 2 20 38.0 - 44.5 2” - 50mm 74 83 052765A 6 - M63s M63 2 2½ 20 44.5 - 50.0 2¼” - 57mm 85 96 052706A 6 - M63 M63 2 2½ 20 50.0 - 56.0 2½” - 63mm 85 96 052707A 7 - M75 M75 2½ 3 20 56.0 - 68.0 3” - 76mm 96 108 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • Factory fitted with a specially formulated elastomeric seal provides built-in safety. • Complete with spigot to attach a hose for cable protection. • Gland can be used on Exd enclosures greater than 2 litres volume. • Complete with orange thread cap / safety gauge for correct gland selection. Technical Data Type FLP-HOSE Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer Cable Type Unarmoured TRS Sealing Area Outer sheath Accessories Spigot flange adaptors, Motor/Switchgear adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SANS / SABS IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC and DIP A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2 GD EExd I M2 EN50014:1997E DEMKO 01 ATEX 130325X EN50018:2000E EPSILON 06 ATEX 2044 EN50019:2000E EN50281-1-1:1999E Operating Temperature -30 to 130 °C Alternative Certification Options Available:• South Africa 5 Tel +44 (0) 1226 352 000 • Chinese www.remora.net Mining Glands Barrier Tex A Remora Electrical Ltd Barrier Tex A Exd I/IIC, Exe I/II, I M2/II 2GD, Ex tD Cable Gland The Barrier Tex A Gland is designed with the MAC Multi Armour Captive-Component, providing an armour clamp and earth bond for Steel wire, Braid, Tape & Pliable wire armoured cable. Providing a flameproof compound barrier seal over the inner cores of the cable, an outer IP seal over the outer sheath of the cable and an armour clamp by means of a cone and cone ring. Seals to IP66/68 when fitted with sealing gasket provided. Entry Thread Gland Code Size 052500A 00 - M20ss M20 ½ 0525-0A 0 - M20s M20 ½ Metric / NPT Minimum Installation Torgue Compound Seal Range Minimum Armour Wire Hexagonal Across Flats 8.0-13.5 0.9 24 11.5-16.0 0.9 24 Max Dia Over Cores Max No of Cores Overall Cable Dia (Min/Max) 25 9 6 25 9 6 052501A 1 - M20 M20 ½ ¾ 28 11 10 14.5-21.0 0.9 24 052502A 2 - M25 M25 ¾ 1” 36 16 20 20.5-27.0 1.25 33 052503A 3 - M32 M32 1” 1¼ 44 22 40 26.5-33.5 1.25 47 052504A 4 - M40 M40 1¼ 1½ 52 27 60 33.0-43.0 1.6 58 052505A 5 - M50 M50 2” 65 37 80 42.5-52.5 2.0 63 052506A 6 - M63 M63 2½ 85 48 100 52.5-65.5 2.5 73 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • No need to change seals or reverse cones or cone rings to accommodate different types of armoured cable. • Armour clamp components can be inspected after installation. • Gland can be used on Exd enclosures greater than 2 litres volume. Technical Data Type BARRIER TEX A Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer (Outer Seal) Cable Type Steel Wire, Braid, Tape, Pliable Wire Armour Armour Clamping Multi Armour Cone and Cone Ring Sealing Area Inner and outer sheath Accessories Spigot flange adaptors, Motor/Switchgear adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC Extd, A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2GD EN60079-0:2006 EN60079-1:2004 EN60079-7:2003 EN61241-0:2006 EN61241-1:2004 SIRA 09ATEX1044X Operating Temperature -20 to 80 °C [email protected] Fax +44 (0)1226 360 510 6 Mining Glands Barrier Tex F Remora Electrical Ltd Barrier Tex F Exd I/IIC, Exe I/II, I M2/II 2GD, Ex tD Cable Gland The Barrier Tex F Gland is designed for use with unarmoured elastomeric and plastic cables where it is necessary to provide an flameproof seal. Barrier Tex F provides a flameproof compound barrier seal over the inner cores of the cable and an outer IP gripper seal. Harder outer seal grips the cable, giving superior cable retention and IP rating. Seals on the cable outer sheath, to IP66/68 when fitted with sealing gasket provided. Entry Thread Compound Seal Range Metric NPT Minimum Installation Torgue 00 - M20ss M20 ½ 35 8 6 5.0-8.0 25 0 - M20s M20 ½ 35 9 6 8.0-11.0 25 052601A 1 - M20 M20 ½ ¾ 50 11 10 11.0-15.5 28 052602A 2 - M25 M25 ¾ 1” 50 16 20 15.0-20.5 36 052603A 3 - M32 M32 1” 1¼ 70 22 40 20.0-26.5 44 052604A 4 - M40 M40 1¼ 1½ 87 27 60 26.0-34.5 52 052655A 5 - M50s M50 2” 110 35 80 32.5-38.0 65 052605A 5 - M50 M50 2” 110 37 80 38.0-44.5 65 052666A 6 - M63s M63 2½ 120 45 100 44.5-50.0 85 052606A 6 - M63 M63 2½ 120 48 100 50.0-56.0 Gland Code Size 052600A 0526-0A Max Dia Over Cores Max No. of Cores Overall Cable Dia ( Min-Max) Hexagonal Across Flats 85 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated at no extra cost. • No loose parts that can get lost during assembly. • Gland can be used on Exd enclosures greater than 2 litres volume. • Complete with orange thread cap / safety gauge for correct gland selection. Technical Data Type BARRIER TEX F Gland Material Brass (Self Colour & Nickel Plated) Seal Material Thermoplastic Elastomer (Outer Seal) Cable Type Unarmoured Sealing Area Inner and outer sheath Accessories Spigot flange adaptors, Motor/Switchgear adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC Extd, A21 CENELEC / ATEX Category 2, Category 3, EExde IIC 2 GD EN60079-0:2006 EN60079-1:2004 EN60079-7:2003 EN61241-0:2006 EN61241-1:2004 SIRA 09ATEX1044X Operating Temperature -20 to 80 °C 7 Tel +44 (0) 1226 352 000 www.remora.net Mining Glands CROCLOCK CR-CB Remora Electrical Ltd CROCLOCK CR-CB Exd I/IIC, Exe II, I M2/II 2GD Cable Gland The CROCLOCK CR-CB type gland provides a Flameproof EExd compound filled barrier, a seal on the outer sheath, a universal armour clamp for armoured, screened or braided cable and an entry thread seal. The armour clamp provides an eletrical bond between the cable armour, screen or braid and the gland. CROCLOCK CR-CB type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 meters and is deluge resistant. Entry Thread Gland Seal Range Cable Inner Sheath/Cores Gland Code Metric NPT Entry Length Max No. Cores Max Over Cores Max Inner Sheath Cable Outer Sheath Standard Min Max Reduced Bore Min Max Armour Acceptance Range CR-CB/16/M16 M16 ½ or ¾ 16 7 9.0 11.7 9.0 13.5 6.7 10.3 0.15 - 1.25 CR-CB/20S/M20 M20s ½ or ¾ 16 8 10.4 11.7 11.5 16.0 9.4 12.5 0.15 - 1.25 CR-CB/20/M20 M20 ½ or ¾ 16 14 12.5 14.0 15.5 21.1 12.0 17.6 0.15 - 1.25 CR-CB/25/M25 M25 ¾ or 1 16 25 17.8 20.0 20.3 27.4 16.8 23.9 0.15 - 1.60 CR-CB/32/M32 M32 1 or 1¼ 16 50 23.5 26.3 26.7 34.0 23.2 30.5 0.15 - 2.00 CR-CB/40/M40 M40 1¼ or 1½ 16 80 28.8 32.2 33.0 40.6 28.6 36.2 0.20 - 2.00 CR-CB/50S/M50 M50s 2 16 100 34.2 38.2 39.4 46.7 34.8 42.4 0.20 - 2.50 CR-CB/50/M50 M50 2 16 100 39.4 44.1 45.7 53.2 41.1 48.5 0.20 - 2.50 CR-CB/63S/M63 M63s 2½ 19 120 44.8 50.1 52.1 59.5 47.5 54.8 0.30 - 2.50 CR-CB/63/M63 M63 2½ 19 120 50.0 56.0 58.4 65.8 53.8 61.2 0.30 - 2.50 CR-CB/75S/M75 M75s 3 19 140 55.4 62.0 64.8 72.2 60.2 68.0 0.30 - 2.50 CR-CB/75/M75 M75 3 19 140 60.8 68.0 71.1 78.0 66.5 73.4 0.30 - 2.50 CR-CB/80/M80 M80 3 or 3½ 25 160 64.4 72.0 77.0 84.0 - - 0.45 - 3.15 CR-CB/85/M85 M85 3 or 3½ 25 180 69.8 78.0 79.6 90.0 75.0 85.4 0.45 - 3.15 CR-CB/90/M90 M90 3½ or 4 25 200 75.1 84.0 88.0 96.0 - - 0.45 - 3.15 CR-CB/100/M100 M100 3½ or 4 25 220 80.5 90.0 92.0 102.0 87.4 97.4 0.45 - 3.15 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated. • Gland can be used on Exd enclosures greater than 2 liters volume. Technical Data CROCLOCK CR-CB Type Gland Material Brass (Self Colour & Nickel Plated) Seal Material LSOH Silicone Cable Type Steel Wire, Braid, Tape, Pliable Wire Armour Inner and outer sheath Sealing Area Spigot flange adaptors, Motor/Switchgear Accessories adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SIRA 03ATEX1479X Gas Group I, IIC, IIB, IIA CENELEC / ATEX Mining equipment Group I M2 EN50014:1998 Enclosure Volume - Any EN50018:2000 Internal Ignition Source - Yes EN50281-1-1:1999E Zone 1 or 2, 21 & 22 IEC 60079-0 (2006-06) IEC 60079-1 (2001-02) Operating Temperature -60 to 85 °C Alternative Certification Options Available:• Gost • CSA • IECEx [email protected] Fax +44 (0)1226 360 510 8 Mining Glands CROCLOCK CR-UB Remora Electrical Ltd CROCLOCK CR-UB Exd I/IIC, Exe II, I M2/II 2GD Cable Gland The CROCLOCK CR-UB type gland provides a Flameproof EExd compound filled barrier, a secondary weather seal on the outer sheath and an entry thread seal. CROCLOCK CR-UB type glands maintain Flameproof EExd integrity on unarmoured cable types and IP protection to IP66, 68 to 100 meters and is deluge resistant. Entry Thread Gland Seal Range Cable Inner Sheath/Cores Gland Code Metric NPT ‘C’ Entry Length Max No. Cores Max Over Cores Max Inner Sheath Cable Outer Sheath Standard Min Max CR-UB/16/M16 M16 ½ or ¾ 16 7 8.4 8.4 3.4 8.4 CR-UB/20S/M20 M20s ½ or ¾ 16 8 10.4 11.7 4.8 11.7 CR-UB/20/M20 M20 ½ or ¾ 16 14 12.5 14.0 9.5 14.0 CR-UB/25/M25 M25 ¾ or 1 16 25 17.8 20.0 11.7 20.0 CR-UB/32/M32 M32 1 or 1¼ 16 50 23.5 26.3 18.1 26.3 CR-UB/40/M40 M40 1¼ or 1½ 16 80 28.8 32.2 22.6 32.2 CR-UB/50S/M50 M50s 2 16 100 34.2 38.2 28.2 38.2 CR-UB/50/M50 M50 2 16 100 39.4 44.1 33.1 33.1 CR-UB/63S/M63 M63s 2½ 19 120 44.8 50.1 39.3 50.1 CR-UB/63/M63 M63 2½ 19 120 50.0 56.0 46.7 56.0 CR-UB/75S/M75 M75s 3 19 140 55.4 62.0 52.3 62.0 CR-UB/75/M75 M75 3 19 140 60.8 68.0 58.0 68.0 CR-UB/80/M80 M80 3 or 3½ 25 160 64.4 72.0 61.9 72.0 CR-UB/85/M85 M85 3 or 3½ 25 180 69.8 78.0 69.1 78.0 CR-UB/90/M90 M90 3½ or 4 25 200 75.1 84.0 74.1 84.0 CR-UB/100/M100 M100 3½ or 4 25 220 80.5 90.0 81.8 90.0 All dimensions are in mm Features and Benefits • Glands available in both brass self colour & brass nickel plated. • Gland can be used on Exd enclosures greater than 2 liters volume. Technical Data Type CROCLOCK CR-UB Gland Material Brass (Self Colour & Nickel Plated) Seal Material LSOH Silicone Cable Type Unarmoured Sealing Area Inner and outer sheath Accessories Spigot flange adaptors, Motor/Switchgear adaptor plate, reducer/adaptor, lock nut, earth tag & shroud Standards and Certifications Hazardous Area Classification SIRA 03ATEX1479X Gas Group I, IIC, IIB, IIA CENELEC / ATEX Mining equipment Group I M2 EN50014:1998 Enclosure Volume - Any EN50018:2000 Zone 1 or 2, 21 & 22 EN50281-1-1:1999E IEC 60079-0 (2006-06) IEC 60079-1 (2001-02) Operating Temperature -60 to 85 °C Alternative Certification Options Available:• Gost • CSA • IECEx 9 Tel +44 (0) 1226 352 000 www.remora.net Spigot Adaptor/ Reducers HAS Remora Electrical Ltd SPIGOT HAS IM2 Ex d I/II 2G Ex d IIB Adaptor/Reducers The HAS Type Spigot Adaptor/Reducers are intended for mounting to flameproof enclosure without compromising the explosion protection provided by the enclosure, in accordance with relevant codes of practice. The enclosure has minimum spigot bore length of 12.5mm. The Adaptor/Reducers are designed to convert the aperture of the associated enclosure into a metric female thread form. The Adaptor consists of an elliptical metallic plate that has a female metric thread form at one end for the connection of Group 1 certified cable glands, at the other end there is a turned cylindrical spigot for insertion into the associated equipment spigot bore. The elliptical portion of the Adaptor has two, counter bored fixing holes for use with cap head screws to secure the Adaptor to the enclosure. Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAS Adaptor/Reducers. Metric Thread Sizes Available ‘*’ Dimension Spigot Code ‘A’ Spigot Size ‘B’ ‘C’ M20 M25 M32 M40 M50 M63 Fixing Size HAS0 / * 19.05 14.0 44.5 Y - - - - - M6 HAS1 / * 25.4 20.0 57.15 Y Y Y - - - M6 HAS2 / * 31.75 26.3 69.85 Y Y Y - - - M8 HAS3 / * 38.1 32.2 82.55 Y Y Y Y - - M8 HAS4 / * 50.8 44.1 95.25 Y Y Y Y Y - M10 HAS5 / * 63.5 56.0 114.3 Y Y Y Y Y Y M10 Note: * is replaced by the applicable spigot & required thread size: e.g. HAS1 / 25.4 / M32 All dimensions are in mm The HAS Spigot Adaptors are available without thread entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. e.g. HAS1 / 25.4 Technical Data Standards and Certifications Type HAS Material Brass Bright Zinc plated Gold Passivation. Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U [email protected] Fax +44 (0)1226 360 510 10 Motor/Switchgear Reducer Plate HAP1 Remora Electrical Ltd Reducer Plate HAP1 IM2 Ex d I/II 2G Ex d IIB The HAP Reducer Plate is intended for mounting to a flameproof enclosure without compromising the explosion protection provided by the motor/switchgear/enclosure. The HAP Reducer is used to convert an existing cable entry aperture of the associated enclosure into a metric female thread form. The Reducer comprises a rectangular metallic plate with four, counter-bored, fixing holes for used with cap head screws. One recessed or fully threaded bore for the connection of a suitable certified cable gland is centrally located. Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAP Reducer Plate. Plate Code HAP1 / * Metric Thread Sizes Available ‘*’ Dimension ‘A’ ‘B’ ‘C’ ‘D’ M25 M32 62 100 32 70 Y Y - - - Fixing Size - M6 All dimensions are in mm Note: * is replaced by the applicable thread size: e.g. HAP1 / M32 The HAP Reducers are available without thread female entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. Technical Data Type HAP1 Material Mild Steel Bright Zinc plated Gold Passivation. Standards and Certifications Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U 11 Tel +44 (0) 1226 352 000 www.remora.net Motor/Switchgear Reducer Plate HAP2 Remora Electrical Ltd Reducer Plate HAP2 IM2 Ex d I/II 2G Ex d IIB The HAP Reducer Plate is intended for mounting to a flameproof enclosure without compromising the explosion protection provided by the motor/switchgear/enclosure. The HAP Reducer is used to convert an existing cable entry aperture of the associated enclosure into a metric female thread form. The Reducer comprises a rectangular metallic plate with four, counter-bored, fixing holes for used with cap head screws. One recessed or fully threaded bore for the connection of a suitable certified cable gland is centrally located. Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAP Reducer Plate. Plate Code HAP2 / * Metric Thread Sizes Available ‘*’ Dimension ‘A’ ‘B’ ‘C’ ‘D’ M25 M32 M40 M50 95 142 65 112 Y Y Y Y M63 M75 Fixing Size Y Y M8 All dimensions are in mm Note: * is replaced by the applicable thread size: e.g. HAP2 / M32 The HAP Reducers are available without thread female entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. Technical Data Standards and Certifications Type HAP2 Material Mild Steel Bright Zinc plated Gold Passivation. Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U [email protected] Fax +44 (0)1226 360 510 12 Motor/Switchgear Reducer Plate HAP3 Remora Electrical Ltd Reducer Plate HAP3 IM2 Ex d I/II 2G Ex d IIB The HAP Reducer Plate is intended for mounting to a flameproof enclosure without compromising the explosion protection provided by the motor/switchgear/enclosure. The HAP Reducer is used to convert an existing cable entry aperture of the associated enclosure into a metric female thread form. The Reducer comprises a rectangular metallic plate with four, counter-bored, fixing holes for used with cap head screws. One recessed or fully threaded bore for the connection of a suitable certified cable gland is centrally located.Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAP Reducer Plate. Plate Code HAP3 / * Metric Thread Sizes Available ‘*’ Dimension ‘A’ ‘B’ ‘C’ ‘D’ M25 M32 M40 M50 120 147 85 112 Y Y Y Y M63 M75 Fixing Size Y Y M10 All dimensions are in mm Note: * is replaced by the applicable thread size: e.g. HAP3 / M32 The HAP Reducers are available without thread female entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. Technical Data Type HAP3 Material Mild Steel Bright Zinc plated Gold Passivation. Standards and Certifications Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U 13 Tel +44 (0) 1226 352 000 www.remora.net Motor/Switchgear Reducer Plate HAP4 Remora Electrical Ltd Reducer Plate HAP4 IM2 Ex d I/II 2G Ex d IIB The HAP Reducer Plate is intended for mounting to a flameproof enclosure without compromising the explosion protection provided by the motor/switchgear/enclosure. The HAP Reducer is used to convert an existing cable entry aperture of the associated enclosure into a metric female thread form. The Reducer comprises a rectangular metallic plate with four, counter-bored, fixing holes for used with cap head screws. One recessed or fully threaded bore for the connection of a suitable certified cable gland is centrally located.Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAP Reducer Plate. Plate Code HAP4 / * Metric Thread Sizes Available ‘*’ Dimension ‘A’ ‘B’ ‘C’ ‘D’ M25 M32 M40 M50 100 100 57 76 Y Y Y Y M63 M75 Fixing Size Y - M10 All dimensions are in mm Note: * is replaced by the applicable thread size: e.g. HAP4 / M32 The HAP Reducers are available without thread female entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. Technical Data Standards and Certifications Type HAP4 Material Mild Steel Bright Zinc plated Gold Passivation. Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U [email protected] Fax +44 (0)1226 360 510 14 Motor/Switchgear Reducer Plate HAP5 Remora Electrical Ltd Reducer Plate HAP5 IM2 Ex d I/II 2G Ex d IIB The HAP Reducer Plate is intended for mounting to a flameproof enclosure without compromising the explosion protection provided by the motor/switchgear/enclosure. The HAP Reducer is used to convert an existing cable entry aperture of the associated enclosure into a metric female thread form. The Reducer comprises a rectangular metallic plate with four, counter-bored, fixing holes for used with cap head screws. One recessed or fully threaded bore for the connection of a suitable certified cable gland is centrally located.Armortex, FLP, FLP-TR & FLP Hose range of cable glands can be used in conjunction with the HAP Reducer Plate. Plate Code HAP5 / * Metric Thread Sizes Available ‘*’ Dimension ‘A’ ‘B’ ‘C’ ‘D’ M25 M32 M40 M50 118 168 83 133 Y Y Y Y M63 M75 M80 M85 Fixing Size Y Y Y Y M12 All dimensions are in mm Note: * is replaced by the applicable thread size: e.g. HAP5 / M32 The HAP Reducers are available without thread female entries, thus becoming blanking devices, the thread size ‘*’ is just omitted from the part code. Technical Data Type HAP5 Material Mild Steel Bright Zinc plated Gold Passivation. Standards and Certifications Hazardous Area Classification CE IM2 Ex d I / II 2G Ex d IIB Sira 06ATEX1149U 15 Tel +44 (0) 1226 352 000 www.remora.net Motor/Switchgear Salvage Plate Remora Electrical Ltd Salvage Plate MSP NON-FLP The HAP Salvage Plate is designed for the protection of motors and switchgear in storage, transite or salvage operations. The plate is fitted using the supplied silicone protection lubricant and uses the original cable entry fixing studs. the fitting of the plate offers protection to the flameproof surfaces and provents ingress of dust and water to the equipment. Plate Code MSP1 Dimension ‘A’ ‘B’ ‘C’ ‘D’ Fixing Size 62 100 32 70 M6 MSP2 95 142 65 112 M8 MSP3 120 147 85 112 M10 MSP4 100 100 57 76 M10 MSP5 118 168 83 133 M12 All dimensions are in mm Technical Data Standards and Certifications Type MSP Material Nylon 6 [email protected] For industrial None-FLP use only Fax +44 (0)1226 360 510 16 Reducers/Adaptors & Stopping Plugs Remora Electrical Ltd Metric-Metric Reducers/Adaptors & Stopping Plugs EExde I/IIC Metric Reducers & Adaptors are designed to effectively reduce or adapt dissimilar thread sizes. Manufactured from high quality brass, suitable for Zone 1 & 2 Hazardous area installations EExde Group I (mining) & Group II (surface). High IP protection obtained to IP66/67/68 when fitted with sealing gasket provided. Reducer Male Thread Female Male Thread Length Adaptor Reducer Code Male Male Thread Length Adaptor Code M20 M16 15 RM20M16E-UN M16 M20 15 AM16M20E-UN M25 M20 15 RM25M20E-UN M20 M25 15 AM20M25E-UN M32 M20 15 RM32M20E-UN M25 M32 15 AM25M32E-UN M32 M25 15 RM32M25E-UN M32 M40 15 AM32M40E-UN M40 M20 15 RM40M20E-UN M40 M50 15 AM40M50E-UN M40 M25 15 RM40M25E-UN M50 M63 15 AM50M63E-UN M40 M32 15 RM40M32E-UN M63 M75 15 AM63M75E-UN M50 M20 15 RM50M20E-UN M50 M25 15 RM50M25E-UN M50 M32 15 RM50M32E-UN M50 M40 15 RM50M40E-UN M63 M32 15 RM63M32E-UN M63 M40 15 RM63M40E-UN M63 M50 15 RM63M50E-UN M75 M63 15 RM75M63E-UN Standards and Certifications Hazardous Area Classification SANS / SABS IEC Zone 1, 2, 21 and 22 Exd I/IIC, Exe I/IIC and DIP Category 2, Category 3, EExde IIC 2 GD CENELEC / ATEX I M2 EN50014:1997E DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 EN50018:2000E EN50019:2000E EN50281-1-1:1999E Alternative Certification Options Available:• South Africa 17 Thread Female Thread Size Male Thread Length Stopper Code M16 15 353016-UN M20 15 353020-UN M25 15 353025-UN M32 15 353032-UN M40 15 353040-UN M50 15 353050-UN M63 15 353063-UN M75 15 353075-UN All dimensions are in mm • Chinese Tel Stopping Plug +44 (0) 1226 352 000 www.remora.net Industrial Glands A2 Remora Electrical Ltd A2 Compression Cable Gland The A2 Compression Gland is designed for use with unarmoured, elastomeric and plastic cable for both indoor & outdoor applications. Seals on the cable sheath, to IP68 if fitted with a sealing gasket. Entry Thread Cable Details (diameter) Max Length ‘C’ Hexagonal Details (max) Gland Code Size Diameter ‘N’ Length ‘D’ Min-Max ‘A’ ‘Flats’ ‘Crns’ 053500 00 - M20ss M20 10 3.0 - 8.0 20 24 27 0535-0 0 - M20s M20 10 7.0 - 11.0 20 24 27 053501 1 - M20 M20 10 11.0 - 15.5 24 27 31 053502 2 - M25 M25 10 15.0 - 20.5 25 35 40 053503 3 - M32 M32 10 20.0 - 26.5 30 42 48 053504 4 - M40 M40 10 26.0 - 34.5 30 52 60 053505 5 - M50 M50 10 34.0 - 44.5 42 65 75 053506 6 - M63 M63 10 44.0 - 57.0 48 82 94 053507 7 - M75 M75 20 56.0 - 68.0 55 96 110 053508 8 - M80 M80 20 65.0 - 74.0 55 96 110 053509 9 - M90 M90 20 73.0 - 82.0 60 110 125 053510 10 - M100 M100 20 81.0 - 92.0 70 * * 053511 11 - M110 M110 20 91.0 - 102.0 70 * * 053512 12 - M120 M120 20 102.0 - 110.0 * * * 053513 13 - M130 M130 20 110.0 - 120.0 * * * All dimensions are in mm Note: Sizes M110 to M130 are of round slotted material, for use with ‘C’ spanner. Please contact us for dimentions Features and Benefits • For indoor / outdoor use. • Seals on cable sheath to IP68. • Wide sealing range. • Precision manufactured from high quality Nickel plated brass. Technical Data Standards and Certifications Type A2 Gland Material Brass (Nickel Plated) Seal Material Thermoplastic Elastomer (Silicone on request) Cable Type Unarmoured Sealing Area Outer sheath Accessories Reducer/adaptor, lock nut & shroud [email protected] BS6121 Part 1 1989 SGS 1542\97153 SANS / SABS 1213 787\80054\D586 IP Protection IP66/68 EN50014:1997E Fax -30 °C to +130 °C +44 (0)1226 360 510 18 Industrial Glands CW Remora Electrical Ltd CW Captive Cone Gland The CW Gland is designed for Steel Wire Armoured cables for general indoor/outdoor use where a seal on the outer sheath is required to obtain an IP rating. The gland features two piece handling, no loose parts & freely rotating captive cone, providing an armour clamp and earth bond without twisting the steel wire armouring. Seals on the cable sheath, to IP66 if fitted with a sealing gasket. Entry Thread Cable Details (diameter) Gland Code Size 051200 00 - M20ss M20 10 3.0 - 8.0 8.0 - 13.5 0512-0 0 - M20s M20 10 8.0 - 12.0 11.5 - 16.0 Diameter ‘N’ Length ‘D’ Min-Max ‘A’ Min-Max ‘B’ Max Length ‘E’ Hexagonal Details (max) ‘Flats’ ‘Crns’ 41 24 27 43 24 27 051201 1 - M20 M20 10 11.0 - 15.5 14.5 - 21.0 47 27 31 051202 2 - M25 M25 10 15.0 - 20.5 20.5 - 27.0 56 35 40 051203 3 - M32 M32 10 20.0 - 26.5 26.5 - 33.5 57 42 48 051204 4 - M40 M40 15 26.0 - 34.5 33.0 - 43.0 68 52 60 051205 5 - M50 M50 15 34.0 - 44.5 42.5 - 52.5 72 65 75 051206 6 - M63 M63 15 44.0 - 57.0 52.0 - 65.5 89 80 90 051207 7 - M75 M75 15 56.0 - 68.0 65.0 - 78.0 97 96 110 051208 8 - M80 M80 20 68.0 - 74.0 77.5 - 82.0 98 100 115 051209 9 - M90 M90 20 74.0 - 82.0 81.0 - 91.0 123 110 125 051210 10 - M100 M100 20 82.0 - 93.0 90.0 - 101.0 * * * All dimensions are in mm Note: Sizes M100 and above are of round slotted material, for use with ‘C’ spanner. Please contact us for dimentions Features and Benefits • For outdoor use. • No loose parts that can get lost during assembly. • Freely rotating captive cone, providing an armour clamp and earth bond without twisting the steel wire armouring. • Provides a seal on the outer sheath of the cable to IP66. • Precision manufactured from high quality Nickel plated brass. Technical Data Type CW Gland Material Brass (Nickel Plated) Seal Material Thermoplastic Elastomer Cable Type Steel Wire Armour / Aluminium Armour Armour Clamping Captive Rotating Cone Sealing Area Outer sheath Accessories Reducer/adaptor, lock nut, earth tag & shroud 19 Tel Standards and Certifications BS6121 Part 1 1989 SGS 3641\99369 SANS / SABS 1213 787\K757 IP Protection IP66 EN50014:1997E +44 (0) 1226 352 000 -30 °C to +130 °C www.remora.net Industrial Glands IP Corrosion Guard Remora Electrical Ltd IP Plus Corrosion Guard Cable Gland The IP Plus Corrosion Guard Gland is designed for use with Steel Wire Armoured (SWA) cable. It provides an IP68 moisture proof seal on the outer sheath of the cable making the gland suitable for use in highly corrosive and wet locations. The screw-on Corrosion Guard is manufactured from non-corrosive material to protect the steel wire armour and metal parts of the gland. Gland Code Size 054600 0546-0 Entry Thread Cable Details (diameter) Max Length ‘E’ Maximum Diameter ‘F’ 8.0 - 13.5 53 35 11.5 - 16.0 53 35 14.5 - 21.0 56 36 14.0 - 20.5 20.5 - 27.0 60 46 19.0 - 26.5 26.5 - 33.5 66 53 15 26.0 - 34.5 33.0 - 43.0 78 68 M50 15 34.0 - 44.5 42.5 - 52.5 87 84 M63 15 44.0 - 57.0 52.0 - 65.5 110 110 M75 15 56.0 - 68.0 65.0 - 78.0 118 124 Diameter ‘N’ Length ‘D’ Min-Max ‘A’ 00 - M20ss M20 10 3.0 - 8.0 0 - M20s M20 10 7.0 - 12.0 054601 1 - M20 M20 10 9.0 - 15.5 054602 2 - M25 M25 10 054603 3 - M32 M32 10 054604 4 - M40 M40 054605 5 - M50 054606 6 - M63 054607 7 - M75 Min-Max ‘B’ All dimensions are in mm Features and Benefits • For use in highly corrosive or wet locations. • Specially formulated IP Plus seals, seals on inner sheath of the cable. • The screw-on Corrosion Guard is manufactured from non-corrosion material to protect the steel wire armour and metal part of the gland. • Corrosion Guard screws onto the gland body and seals over the outer sheath of the cable giving an IP 66/67/68 seal. • Wide sealing range. • Precision manufactured from high quality Nickel plated brass & non-corrosive Glass Reinforced Polyester Compound corrosion guard. Technical Data Type BW Corrosion Guard Gland Material Brass (Nickel Plated) Corrosion Guard Glass Reinforced Polyester Compound / PBT Seal Material Thermoplastic Elastomer Cable Type Steel Wire Armour Outer sheath and total enclosure of gland Sealing Area Accessories Reducer/adaptor, lock nut & earth tag. [email protected] Fax Standards and Certifications BS6121 Part 1 1989 SGS 3641\99367 SANS / SABS 1213 787\85772K756 IP Protection IP66/68 EN50014:1997E -30 °C to +130 °C +44 (0)1226 360 510 20 Junction Boxes Remora Electrical Ltd Utility Box IP68 The Utility Box is a general purpose junction box suitable for all surface applications. It is manufactured from impact, corrosion and UV resistant glass reinforced polyester compound and provides 1,2,3 or 4 way versatility. Srew on lid provides ease of installation and when locked with the special locking key prvents unauthories tampering. 4 WAY Material: IP Ratings: Standard: UV Resistant Glass Reinforced Polyester Compound IP66/67/68 SABS 2333 / IEC 600529 Box Code Gland Size Entry Thread ‘A’ Clear Inside Height ‘B’ Clear Inside Distance ‘C’ Distance of Fixing Holes ‘D’ Earth Rail Fixing Holes ‘E’ 102101 1 - M20 M20x1.5 49 80 122 75 102102 2 - M25 M25x1.5 53 110 158 86 All dimensions are in mm Features and Benefits • Connection box for industrial applications. • Manufactured from impact corrosion and UV resistant glass reinforced polyester compound. • Screw on lid provides ease of installation locked with a special locking key prevents unauthorised tampering and ease of installation. • No exposed metal parts. • Dust and water proof to IP68. • One box offers 1, 2, 3 or 4 way versatility • 4 blanking plugs provided. • No drilling or tapping of cable entries required. • Internal earth continuity ring and earth stud provided. • Mounting studs provided for DIN rail if using terminal blocks. Junction Box Accessories Terminal assemblies are available supplied & fitted ready for installation. Full terminal option list is available on request. 21 Anti-tamper special locking key - prevents unauthorised entry Tel +44 (0) 1226 352 000 www.remora.net Junction Boxes Remora Electrical Ltd Handi-Fit Box IP68 The Handifit Box is a general purpose junction box suitable for all surface applications. It is manufactured from impact, corrosion and UV resistant glass reinforced polyester compound and provides 1,2,3 or 4 way versatility. Srew on lid provides ease of installation and when locked with the special locking key prvents unauthories tampering. Y BOX 4 WAY Material: IP Ratings: Standard: UV Resistant Glass Reinforced Polyester Compound IP66/67/68 SABS 2333 / IEC 600529 Box Code Gland Size Entry Thread ‘A’ Clear Inside Height ‘B’ Clear Inside Distance ‘C’ Distance of Fixing Holes ‘D’ Earth Rail Fixing Holes ‘E’ 0650-0 0 - M20s M20x1.5 52 71 77 65 065001 1 - M20 M20x1.5 58 89 90 80 065002 2 - M25 M25x1.5 67 107 107 98 065003 3 - M32 M32x1.5 105 165 167 140 Box Code Gland Size Entry Thread ‘A’ Clear Inside Height ‘B’ Clear Inside Distance ‘C’ Distance of Fixing Holes ‘D’ Earth Rail Fixing Holes ‘E’ 0651-0 0 - M20s M20x1.5 52 61 107 65 065101 1 - M20 M20x1.5 58 81 127 80 065102 2 - M25 M25x1.5 67 91 150 98 065103 3 - M32 M32x1.5 105 152 235 140 All dimensions are in mm Features and Benefits • Connection box for industrial applications. • Manufactured from impact corrosion and UV resistant glass reinforced polyester compound. • Screw on lid provides ease of installation locked with a special locking key prevents unauthorised tampering and ease of installation. • No exposed metal parts. • Dust and water proof to IP68. • One box offers 1, 2, 3 or 4 way versatility • 4 blanking plugs provided. • No drilling or tapping of cable entries required. • Internal earth continuity ring and earth stud provided. • Mounting studs provided for DIN rail if using terminal blocks. [email protected] Fax +44 (0)1226 360 510 22 Cable Gland Accessories Remora Electrical Ltd Brass Lock Nuts Brass Earth Tags Size Nickel Plated Code Unplated Code Size Nickel Plated Code Unplated Code 16 - M16 BLN16 UBLN16 16 - M16 NPET16 ET16 1 - M20 BLN1 UBLN1 1 - M20 NPET1 ET1 2 - M25 BLN2 UBLN2 2 - M25 NPET2 ET2 3 - M32 BLN3 UBLN3 3 - M32 NPET3 ET3 4 - M40 BLN4 UBLN4 4 - M40 NPET4 ET4 5 - M50 BLN5 UBLN5 5 - M50 NPET5 ET5 6 - M63 BLN6 UBLN6 6 - M63 NPET6 ET6 7- M75 BLN7 UBLN7 7- M75 NPET7 ET7 Plastic Sealing Washers Serrated Washers BZP Size Washer Code Size Washer Code 16 - M16 805516 16 - M16 M16WSER 1 - M20 805520 1 - M20 M20WSER 2 - M25 805525 2 - M25 M25WSER 3 - M32 805532 3 - M32 M32WSER 4 - M40 805540 4 - M40 M40WSER 5 - M50 805550 5 - M50 M50WSER 6 - M63 805563 6 - M63 M63WSER 7- M75 805575 7- M75 M75WSER PVC Gland Shrouds 23 Gland Spanners Size Shroud Code Size Shroud Code 0 - M20s (Long Body) SR0 0 - M20s SPANNER-20S 0 - M20s (Short Body) SF0 1 - M20 SPANNER-20 1 - M20 SF1 2 - M25 SPANNER-25 2 - M25 SF2 3 - M32 SPANNER-32 3 - M32 SF3 4 - M40 SPANNER-40 4 - M40 SF4 5 - M50 SPANNER-50 5 - M50 SF5 6 - M63 SPANNER-63 6 - M63 SF6 7- M75 SPANNER-75 7- M75 SF7 Tel +44 (0) 1226 352 000 www.remora.net Remora Notes Electrical Ltd [email protected] Fax +44 (0)1226 360 510 24 Unit 8a Shortwood Business Park Hoyland S74 9LH Tel: +44 (0) 1226 352 000 Fax: +44 (0) 1226 360 510 email: [email protected] www.remora.net ISSUE NO: MC#0.16