Assembly specification
These instructions are to assemble Dexion Slotted Angle Shelving which conforms with the specifications below.
• Frame heights not more than 2286mm
• Frame depths 400 mm
• Not less than five storage levels in a bay
• Uniformly distributed load per shelf
Refer to your Dexion Supply Centre for assembly of shelving units outside these specifications.
Site requirements
Floor
Should generally be of a solid CONCRETE construction designed to accept the point loads imposed by the shelving legs. Installations on other types of floor,
such as timber, bitumen and tarmac, should be specifically designed to suit the strength of the individual floor.
Dry conditions
Components and load data are based on dry internal applications.
Temperature range
+3°C to +40°C. Applications in chill and cold stores with operating temperatures below +3°C, and where moisture is likely to be present, may require
components with additional corrosion protection.
PAGE 1 of 7
Slotted Angle Shelving
Assembly Instructions and User Guide
Components required
The following is a schedule of the minimum components you require to safely assemble Slotted Angle Shelving. The number of starter and extension
shelving units purchased will determine the final quantities of each component.
Angle Uprights x 4
minimum
Baseplates x 4
minimum
Shelves x 5
minimum
Corner Plates x 12
minimum
Batten x 2
minimum
PAGE 2 of 7
M8x16 Nut and Bolt x 40
minimum
Shelf Clips x 12
minimum
Slotted Angle Shelving
Assembly Instructions and User Guide
Major components
PAGE 3 of 7
Slotted Angle Shelving
Assembly Instructions and User Guide
Assembly instructions
1. A
ttach Baseplates to Angle Uprights
using M8x16 Nuts and Bolts.
2. Using M8x16 Nuts and Bolts fix Corner Plates
to Angle Uprights. Note Angle Upright corners
where a Batten will be attached (top rear and
bottom front of shelving) only require 1
Corner Plate to be affixed.
Rear
Uprights
Angle Uprights
positioned at the rear
of the shelving unit
have 1 Corner Plate
at the top of the Angle
Upright and 2 Corner
Plates at the base of
the Angle Upright.
PAGE 4 of 7
Front
Uprights
Angle Uprights
positioned at the front
of the shelving unit
have 2 Corner Plates
at the top of the Angle
Upright and 1 Corner
Plate at the base of
the Angle Upright.
Slotted Angle Shelving
Assembly Instructions and User Guide
Assembly instructions
3. Secure the top and bottom Shelf to each Corner Plate using M8x16 Nuts and Bolts.
4. S
ecure the Batten by bolting to the Angle Uprights. They are located at the bottom front (as a kick
plate), and at the rear top. Use M8x16 Nuts and Bolts at either end of the Batten when fixing it to
the Angle Upright. Then fix the top and bottom Shelf to form the shelving bay.
Batten
Batten
PAGE 5 of 7
Slotted Angle Shelving
Assembly Instructions and User Guide
Assembly instructions
5. F
it Shelf Clips to desired locations along the
Angle Upright. The Shelf Clip fits into two holes
at 38mm in the Angle Upright to form a rigid
support and location for each Shelf corner.
PAGE 6 of 7
6. Secure Shelves on the Shelf Clips throughout
the bay.
Slotted Angle Shelving
Assembly Instructions and User Guide
Important safety information and guidelines for use
Recommended safe loading
The illustration below depicts the recommended safe loadings from the EU Directive for Manual Handling. This is a guide only, recognising the wide
range of personal capabilities, together with the diversity of handling situations.
General care
Little or no maintenance is required other than cleaning. Wipe with a damp cloth, using a mild detergent (only if required).
• Do not use a hose to spray the shelving
• Do not use abrasive or caustic cleaning agents
Inspections
Periodic inspections should be carried out to identify any damage or issues due to incorrect use. Check for the following:
• Upright fixings are secure
• Shelves are free from damage
• Shelves are not overloaded
• All shelf clips are correctly engaged
• Shelves are fully engaged in the clip slots
• Rack out-of-plumb should not exceed height/500 in both directions
IMPORTANT
If the shelving is damaged it should be reported immediately to ensure the necessary precautionary actions are taken.
It is not recommended to repair damaged components. Any part no longer fit for use should be replaced on a like for like basis.
Never cut and splice in a small piece of upright or apply heat in an attempt to straighten bent components.
Whilst the utmost care is taken to ensure the accuracy of the data and design details shown within, Dexion (Australia) Pty Limited cannot, under any circumstances, be held liable for any injuries, expenses
or loss which may, in any degree, be attributed to the use or adoption of such data and design details. Any modification, repair, or alteration of Dexion products by a third party without written approval from
Dexion voids Dexion’s obligations under the Lifetime Warranty. This document remains the sole property of Dexion (Australia) Pty Limited. © Copyright: Dexion (Australia) Pty Limited